INTRODUCING The 5502A Fluke’s Newest Multi-Product Calibrator Robust, Transportable, Wide Workload Coverage The best fit and value for your calibration workload!

INTRODUCING The 5502A Fluke’s Newest Multi-Product Calibrator Robust, Transportable, Wide Workload Coverage The best fit and value for your calibration

Embed Size (px)

Citation preview

INTRODUCINGThe 5502A

Fluke’s Newest Multi-Product Calibrator

Robust,

Transportable,

Wide Workload Coverage

The best fit and value for your calibration workload!

Improved confidence in

calibration……

Offers the best that the leading Fluke

5500A and 9100 provide as calibrators

and then adds

robust protection & easy

transportability

The NEW 5502A Multi Product Calibrator

The best range of functions, accuracy and value in its classVoltage to 1020V dc or acCurrent to 20.5 A, dc or acFully variable resistance to 1100 MΩAC/DC power with variable phaseContinuously variable capacitance to 110 mFMore than 18 temperature calibration functions for thermocouples or RTDsOptions to calibrate oscilloscopes to 600 MHz

NEW 5502A AT A GLANCE

Recessed banana style

terminals

Additional terminal outputs

up to 20.5 A 300 MHz and 600 MHz Scope

Options

Built with the improved 5522A platform with 5500 level performance specs

What will 5502A offer?

Function Range “Best” 1 Yr Spec

DC Voltage 0 to 1020V 50 PPM

AC Voltage 220 mV to 1020V @ 10 Hz to 500 kHz 300 PPM

DC Current 0 to 20.5A 100 PPM

AC Current 9 μA to 20.5A @ 10 Hz to 30 kHz 900 PPM

Resistance 0 to 1.10 GΩ 90 PPM

Capacitance 220pf – 110mF 0.25%

AC & DC Power

0 to 20.9 kW/VAR Variable

Phase 0 to ±180.00 degrees 0.15 Degrees

Thermocouple source

11 types plus 10 µV / C° & 1 mV / C° 0.14 C°

RTD source 8 types of Pt and Cu RTDs 0.04 C°

Thermocouple measure

11 types plus 10 µV / C° & 1 mV / C° 0.14 C°

Frequency 0.01 to 2 MHz 25 ppm

Scope Cal 300 MHz and 600 MHz options various

• Incorporating the 9100’s functional capabilities not now in the 5500A

20.5 Amps ac & dc

• Adding the new & successful improvements of the 5522A:

Wider resistance and capacitance ranges

Input Overload Protection

Transportability

A new look

• Based on the 5522A technology with banana plug connection terminals

• It continues to offer a calibrator that is fully automatable via GPIB or RS-232 Interfaces

Red indicates improved specs versus the 5500A and/or 9100

Improved current – 20.5 Amps & more• Current to 20.5A dc or ac

– Strong Compliance • 4 to 10 volts dc

• 3 to 7 volts ac

– Extendable to 120A with the 52120A Transconductance Amplifier!

• DC voltage accuracy at 40 ppm (90 days) and 50 ppm (1 year)

• Variable resistance 0 to 1100 MΩ

• Variable capacitance 220 pf to 110 mF

The 5502A Multi Product Calibrator –Improved Performance

Calibrates one of the widest workloads of any electrical calibrator on the market

• Handheld and bench meters (analog and digital) up to 4½ digits

• Current clamps and clamp meters• Thermocouples and RTDs• Process calibrators• Data loggers• Strip and chart recorders• Watt meters• Power harmonics analyzers• Panel meters• Graphical multimeters• Analog or digital handheld and

bench oscilloscopes to 600 MHz

…..and more

The 5502A Multi Product Calibrator – Confidence in Workload

NEW – Premium Input Protection

• Reverse power protection to 300V

peak and more, with immediate

output disconnect on all terminals

• “Check before Connect” process

• Replaceable over-current fuses

• NO COMPROMISE performance

specs with the new protection

systems

The 5502A Multi Product Calibrator – Confidence in Reliability

New larger, open, and more comfortable handles

– mean it is designed to easily and comfortably move to where it is needed

– Easier access to the output binding posts mean fast and reliable test lead connections

The 5502A Multi Product Calibrator – Confidence in Usability

More of what’s new – It is easily transported

• A new Carry Case with wheels and removable front & rear covers– Gets out of the lab and to the job,

and back – easily

– Set up for the on-site and in-situ calibrations is simple with removable covers

Easy to move, setup & calibrate

In short it is …CONFIDENCE

The NEW 5502Agives its users confidence

More than 11 electrical calibration functions for

wide workload coverage with an excellent value

+

Robust Protection, Easy transportability

Benefits of the 5502A

OVERLOAD PROTECTION

A Closer Look At…..

On other calibrators one accidental electrical overload can damage up to 3 internal circuits/systems & the main system board

COSTLY REPAIRS $$$$

Common overload damage

Burned Circuit Assemblies

Blown Chips

What if a technician accidentally connects …….

• AC mains voltage into the resistance terminals no damage

• The calibrator’s test leads to live voltage terminals calibrating an in-situ panel meter no damage

• A thermocouple pair with large a common mode voltage into the TC terminalsno damage

• A Meg ohm meter, initiates a test which applies 100s of volts into the resistance terminals no damage

• A high voltage to ANY Normal, AUX or TC connection terminal no damage

• An external current source to the AUX terminals and drives a current into the calibratoronly the protection fuses need replacement

5502A offers protection from these common errors

Examples of successful protection -

Reverse power protection Immediate output disconnect Check before connect Fuse protection

• With the added capabilities the calibrator will withstand accidental overloads, warn the operator of the error, and continue to calibrate properly – with no damage

• Eliminates costly repairs• No downtime or lost

productivity

Benefits of the overload protection

AUTOMATED CALIBRATION

A Closer Look At…..

MET/CAL Compatibility• 5502A works seamlessly with the MET/CAL

version 8.1, and future versions

• Easy upgrades of earlier systems through

MetSupport Gold or as a purchased upgrade

• The new NVI format for MET/CAL makes

procedure writing easier and insures strong

future compatibility

• Existing 5500A and 9100A procedures will

need to be translated to the new format when

used with the 5502A

Full Remote Control Command

Compatibility• 5502A remote control programming is identical

to 5500 series

• Only the instrument identification response is

the different (5502A rather than 5500A)

Easy Automation of a 5502A

5502A & FLUKE’S OTHER MULTI PRODUCT CALIBRATORS

A Closer Look At…..

The 5080A, 5502A & 5522AFunction Comparison

The 5080A, 5502A & 5522A Workload Comparison

Points of differentiation with 5500A

20

5502A 5500A

Max 20.5 A of dc and ac current Max 11 A of dc and ac current

1100 M ohms max variable resistance 330 M ohms max variable resistance

220 pF to 110 mF variable capacitance 330 pF to 1.1 mF variable capacitance

Input terminal protection to 300V  

Separate Hi current output terminal  

Improved chassis design  

Ergonomic handles

Points of differentiation with 9100

21

5502A 9100

Basic dc accuracy is 50 ppm / year Basic dc accuracy is 60 ppm / year

1100 M ohms max variable resistance 400 M ohms max variable resistance

ACV to 500 kHz ACV to 100 kHz

220 pF to 110 mF variable capacitance 500 pF to 40 mF variable capacitance

.01 Hz to 2 MHz Frequency 0.5 Hz to 10 MHz Frequency

Little or no practical benefit to user Lead connection matNo such function available (recommend a 5320A or optional with 5080A)

9100-135: Insulation/Continuity Tester Calibration Module

Obsolete and not available (use MET/CAL or computer automation) PCMCIA Storage Modules

OPTIONS & ACCESSORIES…..

The 5502A Multi Product Calibrator

5500A-SC300 with Leveled Sine to 300 MHz, rise time < 1ns

5520A-SC600 with Leveled Sine to 600 MHz, rise time < 300 ps

5502A Scope Calibration Options

• Supports the following functions:

– DC Voltage

– AC Voltage (Square wave)

– Fast Edge

– Leveled Sine wave

– Time Markers

– Wave Generator

– Pulse Generator

– TV Trigger

– Input impedance Measurement

– Overload Measurement

• All single test channel plus a trigger channel

• A transportation case to serve the workload both in and out of the lab– The 5522A/CARRYCASE is intended for

lab managed travel over short or medium distances

– Wheels & handle make for easy transportation

– Quick removable covers mean fast set up and in the case usage

• A rugged, padded shipping case for transportation outside of the lab’s control– The 55XX/CASE is designed to

withstand difficult shipping conditions found with public & third party freight carriers

– The best solution for long distance shipping by carries who don’t use the same careful attention as does the lab

Instrument Case Accessories

• 5522A/CARRYCASE

• 55XX/CASE

5500A-525A/Leads Accessory Kit

•Have a complete assortment of leads needed for the full range electrical voltage, current, and thermocouple connections

•The 5500A/LEADS set additionally contains 4 safety leads that aren’t compatible with the 5522A or 525B binding post style terminals

5500A/COIL 50 Turn Coil

9100-200 10 & 50 Turn Coil

Current Coil Accessories

Key Benefits of Automation

• One common software platform across a wide range of workload

• Perform calibrations quickly and efficiently.

• Boost cal lab productivity.• Calibrate mechanical and

dimensional instruments and more.

• Manage all calibration assets in a single MET/TEAM database.

• Keep data secure.

MET/CAL Plus Software

For More Detailed Information

• 5502A Product Brochure– Discusses workload, transportability

and automation– A close up profile of the 5502A– Promotes Fluke’s MPC family with a

summary of all 3 multiproduct calibrators• 5522A• 5502A• 5080A

• Extended Specifications Data Sheet– Full official specifications as published

in the manual

• Either are available in hardcopy or electronic media

• Visit http://www.fluke.com/5502A

Mainframe Models & Accessories

Model Description

5502A MULTI-PRODUCT CALIBRATOR

5502A/3 MULTI-PRODUCT CALIBRATOR + 300MHZ SCOPE OPT

5502A/6 MULTI-PRODUCT CALIBRATOR + 600 MHZ SCOPE OPT

Accessory Description55XX/CASE Transit Case5522A/CARRYCASE 5522A Carry Case With Removable Front/Back Panels   5500A/LEADS Comprehensive Test Lead Kit for 5502A   5500A/COIL 50 Turn Current Coil9100-200 10 and 50 turn Current Coils   Y5537 Rack Mount Kit 7" for 5500A5500A/HNDL Side Handle   5800A-7002K 2 Output Cable Set5800A-7004K 5800A Calibrator BNC Connector Kit

Frequently Asked

Questions

Frequently Asked Questions -

1. What comes standard with the 5502A calibrator? The 5502A calibrator comes standard with all its various electrical functions. Scope calibration capability is optional. Included is a full report of calibration with data. An accredited report of calibration is optional.

2. What options can be installed in the 5502A? The two scope calibration options (300 MHz and 600 MHz) are the only options for this calibrator. These are available at time or purchase or installed by a service center at a future date as an upgrade.

3. Is MET/CAL compatible with the 5502A? Yes MET/CAL Release Version 8.1 is able to fully control the 5502A (Due out in Q3 2012).

4. How will existing MET/CAL users get this version of MET/CAL? Upgrades are available through the MetSupport Gold program, or as a purchased upgrade to an existing system.

31

Frequently Asked Questions -

5. Will existing MET/CAL 5500 or 9100 procedures work with the 5502A? No, because the calibrator’s output terminal configuration is different – and the resulting operator safety issues – a different FSC must be used to operate the 5502A with MET/CAL (rather than use the existing 5500A or 9100 FSCs). 

6. Will the 5502A FSC use the old 5500A style syntax, or the newer 5522A style syntax? The 5502A will use the new Name Value Instrument syntax (NVI) – giving the user better flexibility in use, editing, and future calibrator upgrade compatibility.The 5500A used the old FSC syntax style MET/CAL implemented the 5502A with the new structure of FSC, similar to the 5522A FSC. As a result any 5500A procedures will need to be converted to the new FSC syntax. This can be done by the MET/CAL user, or by a translator process. More information on the translation process will soon to be furnished by the MET/CAL team.Similarly any existing 9100 procedures will need to be translated to the new 5502A MET/CAL FSC syntax.

32

Frequently Asked Questions -

7. Does the 5502A use same the commands of other Fluke 55XX calibrators? Yes the 5502A uses the same remote control commands as the earlier 5500A, 5520A and 5522A series calibrators. The only difference is that it answers the remote ID command with a response - that of being a 5502A. 

8. Does the 5502A emulate the commands of Fluke/Wavetek 9100 calibrators? No the 5502A does not emulate the Fluke/Wavetek 9100 calibrator remote control commands.

9. What is the future availability of the 5500A calibrator? The 5500A will be phased out approximately 6 months after the 5502A introduction.

10. What is the future availability of the 9100 calibrator? The 9100 will soon go on limited availability with a last time buy period soon.

11. Is 5500A upgradable to 5502A? No a 5500A is not upgradeable to a 5502A.

33

Frequently Asked Questions -

12. Is 5502A upgradable to 5522A? No a 5502A is not upgradeable to a 5522A.

13. Will the user/operator manual be available together with 5502A at the same time? Yes, a full user’s manual will be available with the 5502A, in English language, supplied on a CD/DVD with the instrument. The getting started manual will translated in several languages, printed and supplied with the instrument.

14. Is the calibration procedure to calibrate the 5502A will be the same as 5500A? The performance verification procedure for the 5502A is similar, but not identical to the 5500A procedure. There are some range and specification differences between the two instruments.

15. Is a service manual available for the 5502A? A detailed service manual will be available at approximately one year after introduction.

34

The NEW 5502A = CONFIDENCE

What the cal lab loved about the

5500A & 9100 is still there

– More than 11 Functions for

wide workload coverage

• We have added improved

performance and

functionality

– Accuracy

– Current

– Resistance

– Capacitance

plus…

– Robust protection

– Easy use & transportation

THANK YOU FOR YOUR ATTENTION