10
Institute “Mihailo Pupin” July, 2010 www. pupin.rs IMP-AUTOMATION & CONTROL IN ENERGETICS

Institut e “Miha i lo Pupin”

  • Upload
    lizina

  • View
    46

  • Download
    1

Embed Size (px)

DESCRIPTION

IMP- AUTOMATION & CONTROL IN ENERGETICS. Institut e “Miha i lo Pupin”. July, 2010. www. pupin.rs. IMP – Automati on & Control , Ltd . Volgina 15, 11060 Be lgrade Tel: +381 11 2771 017, Fax: +381 11 2774 265 E-mail: [email protected]. Field of activity. Thermal power stations. - PowerPoint PPT Presentation

Citation preview

Page 1: Institut e  “Miha i lo Pupin”

Institute “Mihailo Pupin”

July, 2010

www. pupin.rs

IMP-AUTOMATION & CONTROL IN ENERGETICS

Page 2: Institut e  “Miha i lo Pupin”

Field of activity

Thermal power station

Hydroelectric power station

Management of portable and distribution network

Management of technical systems

Alert and warning systems

Management systems in communal activities

Measuring instruments

Systems for tracking mobile objects

IMP – Automation & Control, Ltd.Volgina 15, 11060 Belgrade

Tel: +381 11 2771 017, Fax: +381 11 2774 265E-mail: [email protected]

Page 3: Institut e  “Miha i lo Pupin”

Thermal power stations

• TPS Morava, 125MW, 2004. • TENT-A2, 210MW, 2005. • TENT-A1, 210MW, 2006. • TENT-A4, 307MW, 2007. • TPS KOSTOLAC-B2, 350MW, 2008. • TENT-A6, 320MW, 2008. • TETO Novi Sad – Boiler 3, 2009.

DCS systems VIEW T-POWER

• Integration with new systems of turbine regulations ALSTOM TGC (TPS Morava, TENT-A4).

• Integration of old systems of turbine regulation (TPS Kostolac-B2).

• Integration of new systems of electrostatic precipitators (TENT-A4, A2, A1).

• Standards of PLC systems IEC 61131.

Characteristics• Communication connection of

electric generator protetction systems and 6kV plants+. (TENT-A4, A2, TPS Kostolac-B2).

• Management and regulation of a turbine K-200 using direct command-control on turbine engine management (TEM).

Page 4: Institut e  “Miha i lo Pupin”

Hydroelectric power station

• HPS Đerdap 2, KTA10, 2005. • HPS Đerdap 2, KTA9, 2006. • HPS Đerdap 2, KTA4, 2007. • HPS Đerdap 2, KTA5, 2007. • HPS Đerdap 2, KTA6, 2008. • HPS Đerdap 2, KTA7, 2008. • HPS Vlasinske, HPS Vrla 1, KTA4 2008.• HPS Ovčar Banja, KTA2, 2008

Aggregate dashboards

• Aggregate dasboard- Systems for aggregate management and protetction and transformer block

• Integration with new systems of turbine regulation LMZ RUSSIA (HPS Đerdap 2).

• Integration of old systems of turbine regulation (HPS Vrla 1).

• Integration of new systems of thermal protection units (HPS Đerdap 2).

Characteristics• Standards of PLC systems IEC

61131. • Redundant management and

protection systems• Integration in a central system

for hydrolectric power station management

• Integration with systems AK1703 ACP (SAT Automation – VAtech)

Page 5: Institut e  “Miha i lo Pupin”

Distribution network management

• DN of Elektrovojvodina, Central system.

– DN ED Pančevo. – DN ED Sombor. – DN ED Ruma. – DN ED Subotica. – DN ED Kikinda.

• DN Elektrosrbija, Kraljevo, Central system.

– DN ED Čačak. – DN ED Trstenik– DN ED Šabac. – DN ED Loznica.

• DN Jugoistok, Niš, Central system.

– ED Pirot. – ED Leskovac.– ED Knjaževac

• DN ED Beograd, Central system.

SCADA systems in DC ED

Page 6: Institut e  “Miha i lo Pupin”

Management of technical systems

• Sava Centar• Airport Belgrade

Building managament

• Management and monitoring of all technical systems from one center

• The highest technological standards of fire protetion, security and degree of process and plant automation

• Self-testing and error control• Efficient and fast staff-users

training• Possibility of system expansion

with simple function upgrade• Integration of systems of other

manufacturers in the unique BMS

Characteristics

Page 7: Institut e  “Miha i lo Pupin”

Alert and warning systems

• A&W System Vranje - 11 alarm stations - 2007• A&W System Višegrad - 5 alarm stations – 2007

and 2008 in two phases;• A&W System Bajina Bašta -2 alarm stations –

2008

References

• Alert signs: according to JUS Z.F.1.002 standard (six basic and two reserve)

• Transmission of speech: range of 300-3400 Hz• Maximal number of alarm stations: 64• Possibility of remote control: individually,

group and selectively• Maximal number of groups (sub-centers): 4• Telecommunication networks: standard

telephone wires, radio connection, LAN, WLAN, VOIP, GPRS, fiber-optic

• Protection in transmission: digital transmission with security CRC code (better than 10-7)

• Probability of wrong execution of commands: <10-27

Characteristics

Page 8: Institut e  “Miha i lo Pupin”

Management systems in communal activities

• KCS Railway Station 2004• KCS on the right bank of Ada 2005• KCS on the left bank of Sava

2005-2008• Belgrade Wastewater Management

Center 2008

Water supply and sewerage

• Pumping stations management at the local level

• Management and control of pumping stations from the Management Center

• Ethernet with FO cables and GSM pumping stations connection with the Management Center

Characteristics

SCADA SISTEMView 2

Switch 3

Switch 1

KVM switch

Orman 1

Orman 2

GPS sat

GPS antena

UPRAVLJAČKI CENTAR JKP BEOGRADSKE KANALIZACIJE

GSM modem

PLC Unitronics

Orman Optike

GPS

PAUK SISTEM

Switch 4

Orman 3

VIDEONADZOR

Switch 2

BLUE HEAT

Video nadzor:Gazela, Galovica,

Ušće...

PLC:ADA-A/B/C

Merma Mesta 1-8

NC K. Milosa

SCADA-SCADAVIEW 6000

Gazela, Galovica, Železnička Stanica,

Dorćol, Ušće...

Page 9: Institut e  “Miha i lo Pupin”

Measuring instruments

• Hydroelectric power station,• Thermal power station,• Portable and distribution

network,• Management systems in water

supply and sewerage systems,• Process industry,• Laboratory use

Great number of installations

• All kinds of electrical sizes in standard electrical signals.

– Active and reactive power,– Current and voltage,– Frequency and power factor,– Resistance converters,

• Variant for installation in the rack system and separate installation.

Characteristics• Fluid certificate 0.2% and 0.5%,

Page 10: Institut e  “Miha i lo Pupin”

Systems for tracking mobile objects

U pravljački podsistem

M obiln ipodsistem

Kom unikacionipodsistemPPositioning, AAutomatic

MManagementanagement and CControl

SPIDER System

System’s structure• Management center

– Tracking mobile objects is performed in the dispatch center

• Communication sub-center– Radio communication GSM/GPRS

• Mobile sub-system– Mobile device PAMC in objects

(vehicles)

System’s advantages• Functions

– Adapting to users’ needs– Reliable data protection

• Hardware– Completely domestic product

adapted to users’ needs• Software

– Modular software which is modified according to users’ requests

References "Potisje " Kanjiža PCE Beogradski vodovod i

kanalizacija PCE Novosadski vodovod i

kanalizacija Serbian Armed Forces Road Enterprise Niš