28
Product Data Sheet PS-00388 January 2000 Model D and DT Mass Flow and Density Sensors Measures liqu i ds, gases, and s l ur ri es

i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Product Data SheetPS-00388

January 2000Model D and DT

Mass Flow and Density Sensors

Measu

res liq

uids

,

gase

s, an

d slur

ries

Page 2: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

2 Micro Motion D and DT Sensors

Model D and DT sensors

Micro Motion® Model D sensors set the standard for

Coriolis flowmeters nearly a quarter century ago.

Today, they continue to provide the same outstanding

measurement performance that made them so

popular.

Working with any of our Coriolis transmitters,

Model D and DT sensors provide flow measurement

for liquids, gases and slurries — simply and directly.

Multivariable capability provides mass flow, volume

flow, density, and temperature measurement — all in

real time, without the need for additional equipment.

A wide variety of models includes standard process

connections for virtually any fluid process. Select

from models with features that include:

Sizes for every needModel D sensors are available in standard models

ranging in size from 1/8- to 6-inch (3 to 150 mm).

High-pressure sensorsSeveral sensors are available in high-pressure

models, for pressure flows up to 5600 psi (386 bar).

Two of these, the DH25 and DH38, are designed for

measuring compressed natural gas (CNG) for legal

trade.

High-temperature sensorsThree models of DT sensors measure process fluids

at high temperatures up to 800°F (426°C), without

the need for purge connections.

High-flow sensorThe D600, our largest sensor, is able to measure

flows up to 25,000 lb/min (680,400 kg/h), making it

ideal for ship loading and unloading, pipeline

transfers, platform production, and LACT

applications.

Housing optionsMost Model D sensors are available with optional

purge connections, and some feature purge

connections and/or rupture disks.

Wetted-part materials for your fluidAll Model D and DT sensors come standard with

316L stainless steel wetted parts. Most models are

also available in nickel alloy, and three models

feature stainless steel flow tubes that are lined with a

Tefzel® coating.

System IntegrationMicro Motion offers a variety of microprocessor-

based transmitters. Depending on the transmitter

model, features include milliampere and

frequency/pulse outputs, transmitter and process

control functions in a single device, and API outputs

for crude oil and other hydrocarbon fluids.

Other options include transmitters that can be

installed in instrument racks or panels, or housed in

NEMA-compliant or explosion-proof enclosures.

Sensors and explosion-proof transmitters can be

installed in the same hazardous area.

Micro Motion is known worldwide for increasing plant

efficiency, production, and profitability. More than

250,000 Micro Motion meters are installed and

working in processes just like yours. Contact us, and

learn more about Model D and DT sensors.

Page 3: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 3

Model D and DT features comparison

Typical line size

D25 1/8 to 1/2 inch (3 to 13 mm)

� � �

D40 1/4 to 1/2 inch (6 to 13 mm)

� � �

D65 1/4 to 1/2 inch (6 to 13 mm)

� � �

D100 1/2 to 1 inch (13 to 25 mm)

� � �

D150 1 to 1-1/2 inch (25 to 38 mm)

� � �

D300 1-1/2 to 3 inch (38 to 75 mm)

� � �

D600 3 to 6 inch (75 to 150 mm)

High-pressure models

DH25 1/8 to 1/2 inch (3 to 13 mm)

� � � �

DH38 1/8 to 1/2 inch (3 to 6 mm)

� � � �

DH100 1/2 to 1 inch (13 to 25 mm)

DH150 1 to 1-1/2 inch (25 to 38 mm)

DH300 1-1/2 to 3 inch (38 to 75 mm)

High-temperature models

DT65 1/4 to 1/2 inch (6 to 13 mm)

DT100 1/2 to 1 inch (13 to 25 mm)

DT150 1 to 1-1/2 inch (25 to 38 mm)

Stan

dard

m

odel

Hig

h-pr

essu

rem

odel

Purg

e fit

tings

avai

labl

e

Rec

omm

ende

d

for

CN

G

Hig

h-te

mpe

ratu

re

mod

el

Rup

ture

dis

kav

aila

ble

Page 4: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

4 Micro Motion D and DT Sensors

Performance specificationsFlow specifications — standard sensors

Nominal flow range (1)

(1) Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.

lb/min kg/hD25 0 to 25 0 to 680D40 0 to 45 0 to 1225D65 0 to 150 0 to 4080D100 0 to 400 0 to 10,890D150 0 to 1400 0 to 38,100D300 0 to 7000 0 to 190,500D600 0 to 25,000 0 to 680,400

Maximum flow rate lb/min kg/hD25 25 680D40 45 1225D65 300 8160D100 800 21,780D150 2800 76,200D300 7000 190,500D600 25,000 680,400

Accuracy (2)

(2) Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.

liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rategas — except D25, D600(3)

(3) Model D600 not rated for gas applications.

±0.65% ± [(zero stability / flow rate) x 100]% of rategas — D25 ±0.50% ± [(zero stability / flow rate) x 100]% of rate

Repeatability (2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rategas — except D25, D600(3) ±0.30% ± [(zero stability / flow rate) x 100]% of rategas — D25 ±0.25% ± [½(zero stability / flow rate) x 100]% of rate

Zero stability lb/min kg/hD25 0.005 0.14D40 0.009 0.24D65 0.03 0.84D100 0.10 3.0D150 0.30 9.0D300 0.70 19.2D600 2.5 66.0

Page 5: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 5

Performance specifications continued

Flow specifications — high-pressure sensors

Nominal flow range (1)

(1) Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.

lb/min kg/hDH25 0 to 25 0 to 680DH38 0 to 25 0 to 680DH100 0 to 400 0 to 10,890DH150 0 to 1400 0 to 38,100DH300 0 to 7000 0 to 190,500

Maximum flow rate lb/min kg/hDH25 25 680DH38 50 1360DH100 800 21,780DH150 2800 76,200DH300 7000 190,500

Accuracy (2)

(2) Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.

liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rategas — except DH25, DH38 ±0.65% ± [(zero stability / flow rate) x 100]% of rategas — DH25, DH38 ±0.50% ± [(zero stability / flow rate) x 100]% of rate

Repeatability (2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rategas — except DH25, DH38 ±0.30% ± [(zero stability / flow rate) x 100]% of rategas — DH25, DH38 ±0.25% ± [½(zero stability / flow rate) x 100]% of rate

Zero stability lb/min kg/hDH25 0.006 0.18DH38 0.025 0.68DH100 0.30 9.0DH150 1.2 32.6DH300 4.0 108.0

Flow specifications — compressed natural gas for legal trade

Maximum flow rate (3)

(3) Maximum velocity when measuring gases: DH25, 100 ft/sec (30 m/sec); DH38, 200 ft/sec (61 m/sec).

lb/min kg/hDH25 25 680DH38 50 1360

Minimum flow rate lb/min kg/hDH25 1.25 34DH38 2.5 68

Minimum measured quantity

lb kgDH25 1.25 0.56DH38 2.5 1.13

Delivery accuracy % of batchDH25 0.5DH38 0.5

Page 6: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

6 Micro Motion D and DT Sensors

Performance specifications continued

Flow specifications — high-temperature sensors

Nominal flow range (1)

(1) Micro Motion has adopted the terminology "nominal flow range." The upper limit of this range is the flow rate at which water at reference conditions causes approximately 15 psid (1 bar) of pressure drop for D and DT sensors.

lb/min kg/hDT65 0 to 150 0 to 4080DT100 0 to 400 0 to 10,890DT150 0 to 700 0 to 19,500

Maximum flow rate lb/min kg/hDT65 300 8160DT100 800 21,780DT150 1400 38,100

Accuracy (2)

(2) Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on reference conditions of water at 68 to 77°F (20 to 25°C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted.

liquid ±0.15% ± [(zero stability / flow rate) x 100]% of rategas ±0.65% ± [(zero stability / flow rate) x 100]% of rate

Repeatability (2) liquid ±0.05% ± [½(zero stability / flow rate) x 100]% of rategas ±0.30% ± [(zero stability / flow rate) x 100]% of rate

Zero stability lb/min kg/hDT65 0.03 0.84DT100 0.08 2.16DT150 0.14 3.84

Page 7: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 7

Performance specifications continued

Density specifications — liquid only

with Model 3500, 3700, RFT9739, Model 5300, or RFT9709 transmitter

with IFT9701 transmitter (1)

(1) Model D600 and DT sensors cannot be used with IFT9701 transmitters.

with RFT9712 transmitter (2)

(2) When used with an RFT9712 and a DMS, NFC, or NOC, density specifications are the same as when used with a Model 3500.

Accuracy g/cc kg/m 3 g/cc kg/m 3 g/cc kg/m 3

D25 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0D40 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0D65 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0D100 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0D150 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0D150 Tefzel (3)

(3) Flow tubes are 316L stainless steel with Tefzel lining.

±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0D300 ±0.0005 ±0.5 ±0.002 ±2.0 ±0.001 ±1.0D300 Tefzel (3) ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0D600 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0

DH25 ±0.004 ±4.0 ±0.004 ±4.0 ±0.008 ±8.0DH38 ±0.004 ±4.0 ±0.004 ±4.0 ±0.008 ±8.0DH100 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0DH150 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0DH300 ±0.001 ±1.0 ±0.002 ±2.0 ±0.002 ±2.0

DT65 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0DT100 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0DT150 ±0.001 ±1.0 n/a n/a ±0.002 ±2.0

Repeatability g/cc kg/m 3 g/cc kg/m 3 g/cc kg/m 3

D25 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0D40 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0D65 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0D100 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0D150 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0D150 Tefzel (3) ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0D300 ±0.0002 ±0.2 ±0.001 ±1.0 ±0.0004 ±0.4D300 Tefzel (3) ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0D600 ±0.0002 ±0.2 n/a n/a ±0.0004 ±0.4

DH25 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0DH38 ±0.002 ±2.0 ±0.002 ±2.0 ±0.004 ±4.0DH100 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0DH150 ±0.001 ±1.0 ±0.001 ±1.0 ±0.002 ±2.0DH300 ±0.0005 ±0.5 ±0.001 ±1.0 ±0.001 ±1.0

DT65 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0DT100 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0DT150 ±0.0005 ±0.5 n/a n/a ±0.001 ±1.0

Range g/cc kg/m 3 g/cc kg/m 3 g/cc kg/m 3

0 to 5 0 to 5000 0 to 5 0 to 5000 0 to 5 0 to 5000

Page 8: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

8 Micro Motion D and DT Sensors

Performance specifications continued

Temperature specifications

Accuracy ±1°C ± 0.5% of reading in °C

Repeatability ±0.2°C

Range °F °CD25 –400 to 350 –240 to 177D40 –400 to 350 –240 to 177D65 –400 to 350 –240 to 177D100 –400 to 400 –240 to 204D150 –400 to 400 –240 to 204D150 Tefzel (1)

(1) Flow tubes are 316L stainless steel with Tefzel lining.

32 to 250 0 to 121D300 –400 to 400 –240 to 204D300 Tefzel (1) 32 to 250 0 to 121D600 (2)

(2) Maximum fluid temperature for CENELEC-approved model D600 sensors is 40°C. Ambient temperature limits for booster amplifier are as follows:

CENELEC-approved model –4 to 104°F (–20 to 40°C)UL-approved and standard models –22 to 131°F (–30 to 55°C)

If ambient and radiant heat will cause the booster amplifier to exceed these limits, a remotely mounted booster amplifier assembly is necessary. Consult the factory for remote-mount booster amplifier information.

–400 to 400 –240 to 204

DH25 –400 to 350 –240 to 177DH38 –400 to 350 –240 to 177DH100 –400 to 400 –240 to 204DH150 –400 to 400 –240 to 204DH300 –400 to 400 –240 to 204

DT65 32 to 800 0 to 426DT100 32 to 800 0 to 426DT150 32 to 800 0 to 426

Page 9: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 9

Performance specifications continued

Pressure ratings

Flow tube rating (1)

(1) Flow tube pressure rating at 77°F (25°C), according to ASME B31.3. For higher operating temperatures, tube pressure needs to be derated as follows:

Stainless steel sensors 7.2% derating from 301 to 400°F (149 to 204°C)Nickel alloy sensors 2% derating from 201 to 300°F (94 to 148°C)

9.2% derating from 301 to 400°F (149 to 204°C)

psi barD25 1900 131D40 1250 86D65 2250 155D100 2250 155D150 1500 103D150 Tefzel (2)

(2) Flow tubes are 316L stainless steel with Tefzel lining.

1000 69D300 740 51D300 Tefzel (2) 740 51D600 625 43

DH25 4000 276DH38 5200 358DH100 5600 386DH150 5400 372DH300 4000 276

DT65 (3)

(3) Pressure rating at 800°F (426°C).

900 62DT100 (3) 900 62DT150 (3) 600 41

Housing All models Housing is not rated for pressure containment.

Page 10: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

10 Micro Motion D and DT Sensors

Performance specifications continued

Typical accuracy, turndown, and pressure drop — standard sensors

To determine accuracy, turndown, and pressure drop using your process variables, use the Micro Motion flowmeter selection guide. Download a free copy from our Web site at www.micromotion.com , or contact your local Micro Motion representative.

Accuracy Accuracy, ±%

100:1turndown

20:1turndown

10:1turndown

1:1turndown

D25 2.15 0.55 0.35 0.17D40 2.15 0.55 0.35 0.17

D65 2.15 0.55 0.35 0.17D100 2.65 0.65 0.40 0.18D150 2.29 0.58 0.36 0.17

D300 1.15 0.35 0.25 0.16D600 1.15 0.35 0.25 0.16

Pressure drop Pressure drop, psi (bar)

100:1turndown

20:1turndown

10:1turndown

1:1turndown

D25 ~0 0.1 (0.01) 0.2 (0.01) 12.4 (0.86)D40 ~0 0.1 (0.01) 0.3 (0.02) 15.0 (1.03)D65 ~0 0.1 (0.01) 0.2 (0.01) 13.6 (0.94)

D100 ~0 0.1 (0.01) 0.2 (0.01) 16.2 (1.12)D150 ~0 0.1 (0.01) 0.2 (0.01) 15.8 (1.09)D300 ~0 0.1 (0.01) 0.2 (0.01) 15.1 (1.04)

D600 ~0 0.1 (0.01) 0.1 (0.01) 7.3 (0.50)

Acc

urac

y, %

Pre

ssur

e dr

op, p

si (

bar)

Nominal flow rate, %

2.5

2.0

1.5

1.0

0.5

0

–0.5

–1.0

–1.5

–2.0

–2.5

18.0

15.0

12.0

9.0

6.0

3.0

0

(1.2)

(1.0)

(0.8)

(0.6)

(0.4)

(0.2)

0 10 20 30 40 50 60 70 80 90 100

20:1

10:1

1:1

D25

D150

D600

100:1

Sample data

Page 11: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 11

Performance specifications continued

Typical accuracy, turndown, and pressure drop — DH38 sensor

To determine accuracy, turndown, and pressure drop using your process variables, use the Micro Motion flowmeter selection guide. Download a free copy from our Web site at www.micromotion.com , or contact your local Micro Motion representative.

Accuracy Accuracy, ±%

100:1turndown

20:1turndown

10:1turndown

1:1turndown

DH38 10.15 2.15 1.15 0.25

Pressure drop Pressure drop, psi (bar)

100:1turndown

20:1turndown

10:1turndown

1:1turndown

DH38 ~0 0.1 (0.01) 0.2 (0.01) 12.0 (0.83)

Acc

urac

y, %

Pre

ssur

e dr

op, p

si (

bar)

Nominal flow rate, %

2.5

2.0

1.5

1.0

0.5

0

–0.5

–1.0

–1.5

–2.0

–2.5

18.0

15.0

12.0

9.0

6.0

3.0

0

(1.2)

(1.0)

(0.8)

(0.6)

(0.4)

(0.2)

0 10 20 30 40 50 60 70 80 90 100

20:1

10:1

1:1100:1

Page 12: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

12 Micro Motion D and DT Sensors

Performance specifications continued

Typical accuracy, turndown, and pressure drop — high-temperature sensors

To determine accuracy, turndown, and pressure drop using your process variables, use the Micro Motion flowmeter selection guide. Download a free copy from our Web site at www.micromotion.com , or contact your local Micro Motion representative.

Accuracy Accuracy, ±%

100:1turndown

20:1turndown

10:1turndown

1:1turndown

DT65 2.15 0.55 0.35 0.17DT100 2.15 0.55 0.35 0.17

DT150 2.15 0.55 0.35 0.17

Pressure drop Pressure drop, psi (bar)

100:1turndown

20:1turndown

10:1turndown

1:1turndown

DT65 ~0 0.1 (0.01) 0.2 (0.01) 13.2 (0.91)

DT100 ~0 0.1 (0.01) 0.2 (0.01) 16.2 (1.12)DT150 ~0 0.1 (0.01) 0.1 (0.01) 4.6 (0.32)

Acc

urac

y, %

Pre

ssur

e dr

op, p

si (

bar)

Nominal flow rate, %

2.5

2.0

1.5

1.0

0.5

0

–0.5

–1.0

–1.5

–2.0

–2.5

18.0

15.0

12.0

9.0

6.0

3.0

0

(1.2)

(1.0)

(0.8)

(0.6)

(0.4)

(0.2)

0 10 20 30 40 50 60 70 80 90 100

20:1

10:1

1:1

DT65

DT100

DT150

100:1

Page 13: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 13

Functional specifications

Environmental influences

Temperature effect on zero

Process temperature effect on zero is defined as the worst-case zero offset due to process fluid temperature change away from the zeroing temperature.

Effect on zero (1)

(1) Nominal flow rate is the upper limit of the nominal flow range.

% of nominal flow rate per °CD25 ±0.01D40 ±0.01D65 ±0.001D100 ±0.001D150 ±0.001D150 Tefzel (2)

(2) Flow tubes are 316L stainless steel with Tefzel lining.

±0.002D300 ±0.004D300 Tefzel (2) ±0.004D600 ±0.004

DH sensors ±0.01

DT sensors ±0.002

Temperature effect on span

Process temperature effect on span is the worst-case output error due to process fluid temperature change away from the calibration temperature. Only Model DT sensors are affected.

Effect on flow outputs Effect on density outputs% of rate per °C g/cc per °C kg/m 3 per °C

DT sensors ±0.005 ±0.00003 ±0.03

Temperature offset The long-term temperature offset causes a shift in sensor calibration, which is attributed to a long-term change in the elasticity modulus as a result of sensor operation at elevated temperatures. The calibration shift is always negative and causes the flowmeter to read lower than the actual flow rate. The effects of this shift can be minimized with periodic calibration. Only Model DT sensors are affected.

OffsetDT sensors Above 600°F (315°C), –0.092% of rate per °C in addition to process

temperature effect (above)

Pressure effect Pressure effect is defined as the change in sensor flow sensitivity due to process pressure change away from the calibration pressure. Pressure effect can be corrected. Only the sensors listed below are affected.

Effect on flow accuracy Effect on density accuracy% of rate per psi

% of rate per bar

g/cc per psi

kg/m 3 per bar

D300 –0.009 –0.131 –0.00001 –0.0175D300 Tefzel (2) –0.009 –0.131 –0.00001 –0.0175D600 –0.005 –0.073 –0.0000031 –0.045

Page 14: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

14 Micro Motion D and DT Sensors

Functional specifications continued

Hazardous area classifications

Intrinsically safe when properly connected to an approved transmitter. Approval agency on sensor approval tag must match agency on transmitter approval tag.

UL is a U.S.A. approvals agency, CSA is a Canadian approvals agency, CENELEC is a European standards organization, and SAA is an Australian approvals agency.

UL D, DH sensors Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and G

DT sensors Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and D

CSA D, DH sensors Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and G

DT sensors Class I, Div. 1, Groups C and DClass I, Div. 2, Groups A, B, C, and DClass II, Div. 1, Groups E, F, and G

CENELEC(1)

(1) CENELEC "T" rating depends on the maximum temperature of the process fluid flowing through the sensor.

Maximum fluid temperature, °CT1 T2 T3 T4 T5 T6

D25, DH25 EEx ib IIC T1...T6 177 177 177 120 85 70DH38 EEx ib IIC T1...T6 177 177 177 120 85 70D40 EEx ib IIC T1...T6 204 204 185 120 85 70D65 EEx ib IIC T1...T6 177 177 177 120 85 70D100, DH100 EEx ib IIB T1...T6 204 204 185 120 85 70D150, DH150 EEx ib IIB T1...T6 204 204 185 120 85 70D300, DH300 EEx ib IIB T1...T6 204 204 162 97 62 47D600 EEx [ib] de IIB T4 40

DT sensors EEx ib IIB T1...T6 409 259 164 99 64 49

SAA D25, DH25 Ex ib IIB T4DH38 Ex ib IIB T4D40 Ex ib IIB T4D100, DH100 Ex ib IIB T4D150, DH150 Ex ib IIB T6D150 Tefzel (2)

(2) Flow tubes are 316L stainless steel with Tefzel lining.

Ex ib IIB T6D300, DH300 Ex ib IIB T4D300 Tefzel (2) Ex ib IIB T4

DT sensors Ex ib IIB T6

Page 15: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 15

Physical specifications

Materials of construction

Standard materials of construction are as follows:SS = 316L stainless steel (SS) flow tubes and flanges, CF-3M SS manifoldsNi = Hastelloy® C-22 nickel alloy (Ni) flow tubes and glands with Hastelloy CW-2M Ni manifoldsNi/SS = Hastelloy C-22 Ni flow tubes with 316L SS manifolds and flangesLined = 316L stainless steel flow tubes with Tefzel® lining

Wetted parts (1)

(1) General corrosion guides do not account for cyclical stress, and therefore should not be relied upon when choosing a wetted material for your Micro Motion sensor. Please refer to Micro Motion’s corrosion guide for material compatibility information.

SS Ni Ni/SS LinedD25 9 9D40 9 9D65 9D100 9 9D150 9 9 9D300 9 9 9D600 9DH25 9DH38 9DH100 9DH150 9DH300 9

DT65 9DT100 9DT150 9

Housing 304 stainless steel

Junction box Epoxy-coated aluminum

Sensor weight

Approximate weight of sensors with noted process fittings.

with process connection type lb kgD25 1/2" ANSI 150 lb WNRF flanges 8 3.6D40 1/2" ANSI 150 lb WNRF flanges 8 3.6D65 1/2" ANSI 150 lb WNRF flanges 17.3 7.8D100 1" ANSI 150 lb WNRF flanges 40 18.2D150 1 1/2" ANSI 150 lb WNRF flanges 46 20.9D300 3" ANSI 150 lb WNRF flanges 113 60.4D600 6" ANSI 150 lb WNRF flanges 1400 635

DH38 3/8" NPT union fittings 8 3.6DH100 1 1/2" high-pressure, clamp-type flanges 80 36.4DH150 1 1/2" high-pressure, clamp-type flanges 80 36.4DH300 4" high-pressure, clamp-type flanges 218 99.1

DT65 1/2" ANSI 300 lb WNRF flanges 52 24DT100 1" ANSI 300 lb WNRF flanges 105 48DT150 1 1/2" ANSI 300 lb WNRF flanges 155 70

Page 16: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

16 Micro Motion D and DT Sensors

D25 and D40 dimensions

Dimensions in inches(mm)

Union fitting detail

6 13/16(173)

Dim. Aface-to-face

2 5/16(59)

#10-32 UNF forgrounding (green

binding head screw)

4 1/8(105)

8 25/32(223)

4 1/2(114)

9(229)

8 3/32(208)

3 15/16(100)

2 7/32(56)

3/4-14NPT F

FLOW

2X 1/2-14 NPTfemale purge

fitting (optional)

4(102)

3/8(10)

Dim. B

6 13/16(173)

Dim. Aface-to-face

9 25/32(248)

10 19/32(269)

1 3/32(28)

Page 17: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 17

D25 process fittings

Fittings for standard-pressure, stainless steel sensors (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1/2-inch ANSI 150 lb weld neck raised face flange 113 10 1/4 (260) 3 1/2 (89)1/2-inch ANSI 300 lb weld neck raised face flange 114 10 5/8 (270) 3 3/4 (95)1/2-inch ANSI 600 lb weld neck raised face flange 115 11 1/8 (283) 3 3/4 (95)3/8-inch NPT female union fitting 119 8 1/8 (206) ---1/2-inch sanitary fitting 121 9 3/4 (248) 1 (25)15 mm DIN PN40 weld neck, DIN 2635, type C face 116 10 7/16 (265) 3 3/4 (95)15 mm JIS 10K weld neck raised face flange 216 10 1/4 (260) 3 3/4 (95)15 mm JIS 20K weld neck raised face flange 118 10 1/4 (260) 3 3/4 (95)

Fittings for standard-pressure, nickel alloy sensors (1)

1/2-inch ANSI 150 lb lap joint flange 124 11 1/4 (286) 3 1/2 (89)1/2-inch ANSI 300 lb lap joint flange 125 11 1/4 (286) 3 3/4 (95)1/2-inch ANSI 600 lb lap joint flange 126 11 1/4 (286) 3 3/4 (95)15 mm DIN PN40 lap joint flange, DIN 2656 217 11 1/4 (286) 3 3/4 (95)15 mm JIS 10K lap joint flange 117 11 1/4 (286) 3 3/4 (95)

Fittings for high-pressure, stainless steel sensors (1)

1-inch high-pressure clamp-type flange(2)

(2) Oteco hub size: 1 OC4. Mating connectors (not included): Grayloc hub size 1 GR4, seal ring size 4; clamp size 1, stainless steel.

225 10 1/4 (260) 2 (51)1/2-inch 900/1500 lb weld neck raised face flange 903 11 31/32 (304) 5 1/4 (133)1/2-inch 2500 lb weld neck raised face flange 905 12 31/32 (329) 4 1/4 (108)3/8-inch NPT female union fitting 119 8 1/8 (206) ---

D40 process fittings

Fittings for standard-pressure, stainless steel sensors (1)Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1/2-inch ANSI 150 lb weld neck raised face flange 113 10 1/4 (260) 3 1/2 (89)1/2-inch ANSI 300 lb weld neck raised face flange 114 10 5/8 (270) 3 3/4 (95)1/2-inch ANSI 600 lb weld neck raised face flange 115 11 1/8 (283) 3 3/4 (95)3/8-inch NPT female union fitting 119 8 1/8 (206) ---1/2-inch sanitary fitting 121 9 3/4 (248) 1 (25)15 mm DIN PN40 weld neck, DIN 2635, type C face 116 10 7/16 (265) 3 3/4 (95)15 mm JIS 10K weld neck raised face flange 216 10 1/4 (260) 3 3/4 (95)15 mm JIS 20K weld neck raised face flange 118 10 1/4 (260) 3 3/4 (95)

Fittings for standard-pressure, nickel alloy sensors (1)

1/2-inch ANSI 150 lb lap joint flange 124 11 1/4 (286) 3 1/2 (89)1/2-inch ANSI 300 lb lap joint flange 125 11 1/4 (286) 3 3/4 (95)1/2-inch ANSI 600 lb lap joint flange 126 11 1/4 (286) 3 3/4 (95)15 mm DIN PN40 lap joint flange, DIN 2656 217 11 1/4 (286) 3 3/4 (95)15 mm JIS 10K lap joint flange 117 11 1/4 (286) 3 3/4 (95)

Page 18: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

18 Micro Motion D and DT Sensors

DH38 dimensions and process fittings

Fittings (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. A, Face-to-faceinches (mm)

3/8-inch NPT female union fitting 119 8 1/8 (206)

Dimensions in inches(mm)

6 13/16(173)

Dim. Aface-to-face

2 5/16(59)

#10-32 UNF forgrounding (green

binding head screw)

4 1/8(105)

8 25/32(223)

4 1/2(114)

9(229)

8 3/32(206)

3 15/16(100)

2 7/32(56)

3/4-14NPT F

FLOW

2X 1/2-14 NPTfemale purge

fitting (optional)

4(102)

3/8(10)

9 25/32(248)

10 19/32(269)

1 3/32(28)

8 25/32(223)

Page 19: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 19

D65 dimensions and process fittings

Fittings (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1/2-inch ANSI 150 lb weld neck raised face flange 113 16 3/16 (411) 3 1/2 (89)1/2-inch ANSI 300 lb weld neck raised face flange 114 16 9/16 (421) 3 3/4 (95)1/2-inch ANSI 600 lb weld neck raised face flange 115 17 1/16 (433) 3 3/4 (95)1/2-inch ANSI 900 lb weld neck raised face flange 237 17 11/16 (449) 4 3/4 (121)1-inch ANSI 150 lb weld neck raised face flange 219 17 1/8 (435) 4 1/4 (108)1-inch ANSI 300 lb weld neck raised face flange 241 17 5/8 (448) 4 7/8 (124)1-inch ANSI 600 lb weld neck raised face flange 918 18 (457) 4 7/8 (124)1-inch ANSI 900/1500 lb weld neck raised face flange 919 18 7/8 (479) 5 7/8 (149)3/4-inch NPT female union fitting 239 14 5/16 (364) 1 3/16 (30)1-inch sanitary fitting 238 16 (406) 2 (51)15 mm DIN PN40 weld neck, DIN 2635, type C face 116 15 7/16 (392) 3 3/4 (95)15 mm JIS 10K weld neck raised face flange 216 15 3/16 (386) 3 3/4 (95)15 mm JIS 20K weld neck raised face flange 118 15 3/8 (391) 3 3/4 (95)

Dimensions in inches(mm)

12 1/2(316)

Dim. Aface-to-face

2 5/16(59)

#10-32 UNF for grounding (green binding head screw)

1 7/16(37)

11(279)

5 1/2(140)

3 15/16(100)

3 1/2(89)

3/4-14NPT F

FLOW

4(102)

1 1/2(38)

14(356)

16 11/16(424)

1 1/2(38)

1/2-14 NPT male hex plug

2X

1/2-14 NPT female purge fitting (optional)

2X

3(76)

3/8(10)

1/2" female NPT conduit bushing

12 1/2(316)

Dim. Aface-to-face

Union fitting detail

1 1/2(38)

1 7/16(37)

Dim. B

Page 20: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

20 Micro Motion D and DT Sensors

D100, D150, and standard-pressure D300 dimensions

Standard-pressure sensorsDimensions (1)

(1) For dimensions A and B, see process fittings tables, pages 21–22.

C D E F G H J K LD100 inches

(mm)12 1/4(311)

6 1/8(156)

24 3/4(629)

23 5/16(592)

21 9/32(541)

4(102)

12 7/8(327)

4(102)

2(51)

D150 inches(mm)

12 1/4(311)

6 1/8(156)

24 3/4(629)

23 5/16(592)

21 9/32(541)

4(102)

12 7/8(327)

4(102)

2(51)

D300 inches(mm)

17(432)

8 1/2(216)

39 7/16(1002)

36 15/16(938)

33 27/32(860)

4 1/2(114)

17 7/8(454)

7 1/4(184)

3 5/8(92)

High-pressure sensorsDH100 inches

(mm)12 1/4(311)

6 1/8(156)

24 27/32(631)

23 13/32(595)

21 3/8(543)

4(102)

12 7/8(327)

4(102)

2(51)

DH150 inches(mm)

12 3/4(324)

6 3/8(162)

28 11/32(720)

26 29/32(683)

24 29/32(633)

4(102)

12 7/8(327)

4 1/2(114)

2 1/4(57)

Dimensions in inches(mm)

#10-32 UNF for grounding (green binding head screw)

1 7/16(37)

3 15/16(100)

3/4-14NPT F

FLOW

2(51)

1/2-14 NPT male hex plug

2X

1/2-14 NPT female purge fitting (optional)

2X

2(51)

1 7/16(37)

B

H

K

DL

J

C

EFG

A

2 5/16(59)

3/8(10)

Page 21: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 21

D100 process fittings

Fittings for standard-pressure, stainless steel sensors (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1-inch ANSI 150 lb weld neck raised face flange 128 17 1/8 (435) 4 1/4 (108)1-inch ANSI 300 lb weld neck raised face flange 129 17 5/8 (448) 4 7/8 (124)1-inch ANSI 600 lb weld neck raised face flange 130 18 1/8 (460) 4 7/8 (124)1-inch sanitary fitting 138 16 (406) 2 (51)25 mm DIN PN40 weld neck, DIN 2635, type C face 131 15 29/32 (404) 4 17/32 (115)25 mm JIS 10K weld neck raised face flange 212 15 3/4 (400) 4 29/32 (125)25 mm JIS 20K weld neck raised face flange 133 15 29/32 (404) 4 29/32 (125)

Fittings for standard-pressure, nickel alloy sensors1-inch ANSI 150 lb lap joint flange 134 18 1/2 (270) 4 1/4 (108)1-inch ANSI 300 lb lap joint flange 135 18 1/2 (270) 4 7/8 (124)1-inch ANSI 600 lb lap joint flange 136 18 1/2 (270) 4 7/8 (124)25 mm DIN PN40 lap joint flange, DIN 2656 213 18 1/2 (270) 4 17/32 (115)25 mm JIS 10K lap joint flange 132 18 1/2 (270) 4 29/32 (125)

Fittings for high-pressure, stainless steel sensors1 1/2-inch high-pressure clamp-type flange(2)

(2) Oteco hub size: 1½ OC11. Mating connectors (not included): Grayloc hub size 1½ GR11, seal ring size 11; clamp size 1½, stainless steel.

140 17 1/2 (445) 3 1/8 (79)1-inch ANSI 900/1500 lb weld neck raised face flange 925 19 1/16 (484) 5 7/8 (149)1-inch ANSI 2500 lb weld neck raised face flange 927 20 9/32 (515) 6 1/4 (159)

D150 process fittings

Fittings for standard-pressure, stainless steel sensorsFitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1 1/2-inch ANSI 150 lb weld neck raised face flange 141 17 5/8 (448) 5 (127)1 1/2-inch ANSI 300 lb weld neck raised face flange 142 18 1/8 (460) 6 1/8 (156)1 1/2-inch ANSI 600 lb weld neck raised face flange(3)

(3) Not available with Tefzel sensors.

143 18 3/4 (476) 6 1/8 (156)2-inch ANSI 150 lb weld neck raised face flange(3) 218 17 25/32 (452) 6 (152)1 1/2-inch sanitary fitting(3) 151 16 (406) 2 (51)40 mm DIN PN40, DIN 2635, type C face 144 16 5/16 (414) 5 29/32 (150)40 mm JIS 10K weld neck raised face flange(3) 214 16 1/16 (408) 5 1/2 (140)40 mm JIS 20K weld neck raised face flange(3) 146 16 3/8 (416) 5 1/2 (140)

Fittings for standard-pressure, nickel alloy sensors1 1/2-inch ANSI 150 lb lap joint flange 147 19 1/4 (489) 5 (127)1 1/2-inch ANSI 300 lb lap joint flange 148 19 1/4 (489) 6 1/8 (156)1 1/2-inch ANSI 600 lb lap joint flange 149 19 1/4 (489) 6 1/8 (156)40 mm DIN PN40 lap joint flange, DIN 2656 215 19 1/4 (489) 5 29/32 (150)40 mm JIS 10K lap joint flange 145 19 1/4 (489) 5 1/2 (140)

Fittings for high-pressure, stainless steel sensors1 1/2-inch high-pressure clamp-type flange(4)

(4) Oteco hub size: 1½ OC14. Mating connectors (not included): Grayloc hub size 1½ GR14, seal ring size 14; clamp size 1½, stainless steel.

154 17 1/2 (445) 3 1/8 (79)1 1/2-inch ANSI 900/1500 lb weld neck raised face flange 936 19 25/32 (502) 7 (178)1 1/2-inch ANSI 2500 lb weld neck raised face flange 938 22 1/32 (560) 8 (203)

Page 22: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

22 Micro Motion D and DT Sensors

High-pressure DH300 dimensions, D300 and DH300 process fittings

Fittings for standard-pressure, stainless steel sensors (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

3-inch ANSI 150 lb weld neck raised face flange 155 23 1/4 (591) 7 1/2 (191)3-inch ANSI 300 lb weld neck raised face flange 156 24 (610) 8 1/4 (210)3-inch ANSI 600 lb weld neck raised face flange(2)

(2) Not available with Tefzel sensors.

157 24 3/4 (629) 8 1/4 (210)3-inch sanitary fitting(2) 161 21 3/8 (543) 3 19/32 (91)80 mm DIN PN40, DIN 2635, type C face 158 22 5/16 (567) 7 7/8 (200)80 mm JIS 10K weld neck raised face flange(2) 159 21 11/16 (551) 7 9/32 (185)80 mm JIS 20K weld neck raised face flange(2) 160 22 5/16 (567) 7 7/8 (200)

Fittings for standard-pressure, nickel alloy sensors (1)

3-inch ANSI 150 lb lap joint flange 203 25 5/8 (651) 7 1/2 (191)3-inch ANSI 300 lb lap joint flange 204 25 5/8 (651) 8 1/4 (210)80 mm DIN PN40 lap joint flange, DIN 2656 211 25 5/8 (651) 7 7/8 (200)80 mm JIS 10K lap joint flange 210 25 5/8 (651) 7 9/32 (185)

Fittings for high-pressure, stainless steel sensors (1)

4-inch high-pressure clamp-type flange(3)

(3) Oteco hub size: 4 OC27. Mating connectors (not included): Grayloc hub size 4 GR27, seal ring size 27; clamp size 4, stainless steel.

164 25 1/16 (634) 6 (151)3-inch ANSI 300 lb weld neck raised face flange 156 24 (610) 8 1/4 (210)3-inch ANSI 600 lb weld neck raised face flange 157 24 3/4 (629) 8 1/4 (210)3-inch ANSI 900 lb weld neck raised face flange 246 26 5/16 (668) 9 1/2 (241)3-inch ANSI 1500 lb weld neck raised face flange 946 27 9/16 (700) 10 1/2 (267)3-inch ANSI 2500 lb weld neck raised face flange 947 31 9/16 (802) 12 (305)

Dimensions in inches(mm)

2 5/16(59)

#10-32 UNF for grounding (green binding head screw)

17(432)

8 1/2(216)

3 15/16(100)

8 3/4(221)

3/4-14NPT F

FLOW

4 1/2(114)

2(51)

3 5/8(92)

1/2-14 NPT male hex plug

2X

1/2-14 NPT female purge fitting (optional)

2X

7 1/4(184)

3/8(10)

17 7/8(454)

Dim. Aface-to-face

2(51)

1 7/16(37)

Dim. B

36 15/16(938)

39 7/16(1002)

33 27/32(860)

1 7/16(37)

Page 23: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 23

D600 dimensions and process fittings

Fittings (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

6-inch ANSI 150 lb weld neck raised face flange 165 43 (1092) 11 (279)6-inch ANSI 300 lb weld neck raised face flange 166 43 3/4 (1111) 12 1/2 (317)150 mm DIN PN40 weld neck, DIN 2635, type C face 167 42 1/16 (1068) 11 55/64 (301)150 mm JIS 10K weld neck raised face flange 168 40 15/32 (1028) 11 1/16 (281)150 mm JIS 20K weld neck raised face flange 169 42 1/16 (1068) 12 1/16 (306)

Dimensions in inches(mm)

36(914)

Dim. Aface-to-face

68 11/16(1745)

2 9/16(65)

12 1/2(318)

FLOW

Snub-mount connector

16 1/2(419)

33 3/4(858)

75 7/16(1916)

80 13/16(2053)

1/2-14 NPT F conduit opening

1/2-14 NPT Fconduit opening

#10-32 UNC forgrounding

Dim. B

Page 24: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

24 Micro Motion D and DT Sensors

DT sensor dimensions and process fittings

High-temperature sensorsDimensionsC D E F G H

DT65 inches(mm)

25 1/2(648)

9(229)

5 1/2(140)

15 1/2(394)

20(508)

16(406)

DT100 inches(mm)

29 1/2(749)

10(254)

6 1/2(165)

17 1/2(444)

24(610)

18(457)

DT150 inches(mm)

35 1/2(902)

11 1/2(292)

8(203)

20 1/2(521)

30(762)

21(533)

Fittings for DT65 sensors (1)

(1) Fittings listed here are standard options. Other types of fittings are available. Contact your local Micro Motion representative.

Fitting code

Dim. AFace-to-faceinches (mm)

Dim. BOutside diameterinches (mm)

1/2-inch ANSI 300 lb weld neck raised face flange 114 23 7/8 (606) 3 3/4 (95)1/2-inch ANSI 600 lb weld neck raised face flange 115 23 7/8 (606) 3 3/4 (95)15 mm DIN PN40 weld neck, DIN 2635, type C face 116 22 3/4 (578) 3 3/4 (95)15 mm JIS 20K weld neck raised face flange 118 22 3/4 (578) 3 3/4 (95)

Fittings for DT100 sensors (1)

1-inch ANSI 300 lb weld neck raised face flange 129 29 23/32 (755) 4 7/8 (124)1-inch ANSI 600 lb weld neck raised face flange 130 30 7/32 (768) 4 7/8 (124)25 mm DIN PN40 weld neck, DIN 2635, type C face 131 28 (711) 4 17/32 (115)25 mm JIS 20K weld neck raised face flange 133 28 (711) 4 59/64 (125)

Fittings for DT150 sensors (1)

1 1/2-inch ANSI 300 lb weld neck raised face flange 142 39 1/32 (992) 6 1/8 (156)1 1/2-inch ANSI 600 lb weld neck raised face flange 143 39 43/64 (1008) 6 1/8 (156)40 mm DIN PN40 weld neck, DIN 2635, type C face 144 37 13/64 (945) 5 29/32 (150)40 mm JIS 20K weld neck raised face flange 146 37 13/64 (945) 5 33/64 (140)

Dimensions in inches(mm)

Groundingbolt

2 3/4(70)

FLOW

4 1/2(114)

B

H

D

C

E

F

G

A

2X lifting handle

Page 25: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 25

Ordering Information

Model D, standard-pressure sensors, model number matrix

Code Sensor model

DS025 D25 1/4-inch sensor, standard pressureDS040 D40 3/8-inch sensor, standard pressureDS065 D65 1/2-inch sensor, standard pressureDS100 D100 1-inch sensor, standard pressureDS150 D150 1 1/2-inch sensor, standard pressureDS300 D300 3-inch sensor, standard pressureDS600 D600 6-inch sensor, standard pressure

Code Wetted material

S 316L stainless steelH Hastelloy® C-22 nickel alloy — not available with DS065 or DS600Z 316L stainless steel with Tefzel® lining — DS150 and DS300 only

Code Process connections

### See fittings tables on pages 17-23

Code Case option

S Standard pressure containmentP Purge fittings — (2) 1/2" NPT female; not available with DS600D Metal rupture disk — not available with DS600

Code Approvals

M Micro Motion standard — no approvalsU UL intrinsically safe — U.S.A. approvals agencyC CSA — Canadian approvals agency, not available with DS600B CENELEC — European approvals agencyS SAA — Australian approvals agency, not available with DS600

Code Booster amplifier power voltage — D600 only

1 110/115 VAC2 220/230 VAC

Example *

DS025 S 113 S U

*Example: DS025 S 113 S U = Model D25 1/4-inch standard-pressure sensor, 316L stainless steel; 1/2-inch ANSI 150 lb weld neck raised face flanges; standard pressure containment; UL approved for intrinsically safe installations

Page 26: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

26 Micro Motion D and DT Sensors

Ordering Information continued

Model DH, high-pressure sensors, model number matrix

Code Sensor model

DH025 DH25 1/4-inch sensor, high pressureDH038 DH38 3/8-inch sensor, high pressureDH100 DH100 1-inch sensor, high pressureDH150 DH150 1 1/2-inch sensor, high pressureDH300 DH300 3-inch sensor, high pressure

Code Wetted material

S 316L stainless steel

Code Process connections

### See fittings tables on pages 17-22

Code Case option

S Standard pressure containmentP Purge fittings — (2) 1/2" NPT female, not available with DH100, DH150, or DH300D Metal rupture disk — not available with DH100, DH150, or DH300

Code Approvals

M Micro Motion standard — no approvalsU UL intrinsically safe — U.S.A. approvals agencyC CSA — Canadian approvals agencyB CENELEC — European approvals agencyS SAA — Australian approvals agency

Example *

DH038 S 119 S U

*Example: DH038 S 119 S U = Model DH38 3/8-inch high-pressure sensor, 316L stainless steel; 3/8-inch NPT female union fittings; standard-pressure case; UL approved for intrinsically safe installations

Page 27: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion D and DT Sensors 27

Ordering Information continued

Model DT, high-temperature sensors, model number matrix

Code Sensor model

DT065 DT65 1/2-inch sensor, standard pressure, high temperatureDT100 DT100 1-inch sensor, standard pressure, high temperatureDT150 DT150 1 1/2-inch sensor, standard pressure, high temperature

Code Wetted material

H Hastelloy® C-22 nickel alloy

Code Process connections

### See fittings tables on page 24

Code Case option

G Standard high-temperature case

Code Approvals

M Micro Motion standard — no approvalsU UL intrinsically safe — U.S.A. approvals agencyC CSA — Canadian approvals agencyB CENELEC — European approvals agency

Example *

DT100 H 129 G U

*Example: DT100 H 129 G U = Model DT100 1-inch, standard-pressure, high-temperature sensor; Hastelloy ® C-22 nickel alloy; 1-inch ANSI 300 lb weld neck raised face flanges; standard high-temperature case; UL approved for intrinsically safe installations

Page 28: i , ri es Model D and DT January 2000 PS-00388 s l ur d Mass Flow … · 2015-03-12 · 6 Micro Motion D and DT Sensors Performance specifications continued Flow specifications —

Micro Motion Inc. USAWorldwide Headquarters7070 Winchester CircleBoulder, Colorado 80301Tel (303) 530-8400

(800) 522-6277Fax (303) 530-8459

Micro Motion EuropeGroeneveldselaan 83903 AZ VeenendaalThe NetherlandsTel +31 (0) 318 549 549Fax +31 (0) 318 549 559

Micro Motion Asia1 Pandan CrescentSingapore 128461Republic of SingaporeTel (65) 777-8211Fax (65) 770-8003

For the latest Micro Motion product specifications, view the PRODUCTS section of our Web site at at www.micromotion.com

Micro Motion JapanShinagawa NF Bldg. 5F1-2-5, Higashi ShinagawaShinagawa-kuTokyo 140-0002 JapanTel (81) 3 5769-6803Fax (81) 3 5769-6843

Due to Micro Motion’s commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion is a registered trademark of Micro Motion, Inc., Boulder, Colorado. PlantWeb is a registered trademark of Fisher-Rosemount, Clayton, Missouri. Hastelloy is a registered trademark of Haynes International, Inc., Kokomo, Indiana. Tefzel is a registered trademark of E.I. Du Pont de Nemours Co., Inc., Wilmington, Delaware.

©2000, Micro Motion, Inc.All rights reservedPS-00388 (1/00)