Page 1 of 13WIKA data sheet PE 81.61 ∙ 08/2014
WIKA data sheet PE 81.61
Electronic pressure measurement
High-quality pressure transmitterFor general industrial applicationsModel S-20
Pressure transmitter model S-20
Applications
■ Critical industrial applications ■ Demanding applications in research and development ■ Harsh environments in the process industry
Special features
■ Measuring ranges from 0 ... 0.4 to 0 ... 1,600 bar (0 ... 10 to 0 ... 20,000 psi)
■ Non-linearity of up to 0.125 % of span ■ Different output signals, e.g. 4 ... 20 mA, DC 0 ... 10 V,
DC 1 ... 5 V and others ■ Market-standard electrical connections, e.g.
DIN EN 175301-803 A angular connector ■ Common international process connections
Description
The model S-20 pressure transmitter for general industrial applications is the ideal solution for customers with demand-ing measuring requirements. It features a very good accura-cy, a robust design and an exceptional number of variants, meaning it can be suited to the widest range of applications.
VersatileThe model S-20 offers continuous measuring ranges between 0 ... 0.4 and 0 ... 1,600 bar (0 ... 10 to 0 ... 20,000 psi) in all the major units.These measuring ranges can be combined in almost any way with all the standard industry output signals, the most common international process connections and a wide number of electrical connections.Furthermore, it offers numerous options, such as different accuracy classes, extended temperature ranges and custom-er-specific pin assignments.
High qualityThe robust design turns the model S-20 into a very high quality product, which even the most adverse environmental conditions cannot affect. Whether with the lowest tempera-tures when used outdoors, with extreme shock and vibration in machine building or with aggressive media in the chemical industry, this transmitter can meet all requirements.
AvailabilityAll variants described in this data sheet are available on very short lead times. For particularly urgent demands, there is a sizeable stock available.
Data sheets showing similar products:Pressure transmitter for general industrial applications; model A-10; see data sheet PE 81.60
Page 2 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
Measuring ranges
Gauge pressure
bar 0 ... 0.4 0 ... 0.6 0 … 1 0 … 1.6 0 … 2.5 0 … 4 0 … 60 … 10 0 … 16 0 … 25 0 … 40 0 … 60 0 … 100 0 … 1600 … 250 0 …. 400 0 … 600 0 … 1,000 0 … 1,600
psi 0 … 10 0 … 15 0 … 25 0 … 30 0 … 50 0 … 60 0 … 1000 … 150 0 … 160 0 … 200 0 … 250 0 … 300 0 … 400 0 … 5000 … 600 0 … 750 0 … 1,000 0 … 1,500 0 … 2,000 0 … 3,000 0 … 4,0000 … 5,000 0 … 6,000 0 … 7,500 0 … 10,000 0 … 15,000 0 … 20,000
Absolute pressure
bar 0 … 0.4 0 … 0.6 0 … 1 0 … 1.6 0 … 2.5 0 … 4 0 … 60 … 10 0 … 16 0 … 25 0 … 40
psi 0 … 10 0 … 15 0 … 25 0 … 30 0 … 50 0 … 60 0 … 1000 … 150 0 … 160 0 … 200 0 … 250 0 … 300 0 … 400 0 … 500
Vacuum and +/- measuring range
bar -0.4 … 0 -0.6 … 0 -1 … 0 -1 … +0.6 -1 … +1.5-1 … +3 -1 … +5 -1 … +9 -1 … +15 -1 … +24-1 … +39 -1 … +59
psi -30 inHg ... 0 -30 inHg ... +15 -30 inHg ... +30 -30 inHg ... +45 -30 inHg ... +60-30 inHg ... +100 -30 inHg ... +160 -30 inHg ... +200 -30 inHg ... +300 -30 inHg ... +500
The given measuring ranges are also available in kg/cm2, kPa and MPa.Special measuring ranges between 0 ... 0.4 and 0 ... 1,600 bar (0 ... 10 bis 0 ... 20,000 psi) are available on request.Special measuring ranges have a reduced long-term stability and increased temperature errors.
Overpressure limitThe overpressure limit is based on the sensor element used. Depending on the selected process connection and sealing, restrictions in overpressure safety can result.A higher overpressure limit will result in a higher temperature error.
Available overpressure limitsMeasuring range < 10 bar (150 psi) ≥ 10 bar (150 psi)
Standard 3 times 2 times 1)
Option 5 times 3 times 2) 3)
1) Restriction: max. 60 bar (870 psi) with absolute pressure2) Only possible for gauge pressure measuring ranges ≤ 400 bar (5,800 psi)3) Only possible for absolute pressure measuring ranges < 16 bar (220 psi)
Vacuum tightnessYes
Reference conditions (per IEC 61298-1)
Temperature: 15 ... 25 °C (59 ... 77 °F)Atmospheric pressure: 860 ... 1,060 mbar (12.5 ... 15.4 psi)Humidity: 45 ... 75 % r. h.Power supply: DC 24 V, DC 5 V with ratiometric outputMounting position: Calibrated in vertical mounting position with pressure connection facing downwards.
Page 3 of 13WIKA data sheet PE 81.61 ∙ 08/2014
Output signal
Available output signalsSignal type SignalCurrent (2-wire) 4 ... 20 mA
20 ... 4 mAVoltage (3-wire) DC 0 ... 10 V
DC 0 ... 5 VDC 1 ... 5 VDC 0.5 ... 4.5 VDC 1 ... 6 VDC 10 ... 0 V
Ratiometric (3-wire) DC 0.5 ... 4.5 V
Other output signals on request.
Permissible load in Ω
■ Current output (2-wire)≤ (power supply - 7.5 V) / 0.023 A
with optional settling time of 1 ms:≤ (power supply - 11.5 V) / 0.023 A
■ Voltage output (3-wire)> maximum output voltage / 1 mA
■ Ratiometric output (3-wire):> 4.5k
Signal limiting (option)4 ... 20 mA: Zero point:
Full scale:3.6 mA 4) / 3.8 mA / 4.0 mA20 mA / 21.5 mA / 23 mA
DC 0 ... 10 V: Full scale: DC 10 V / DC 11.5 V4) Not possible in combination with zero point adjustment by the customer
Voltage supply
Power supplyMaximum power supply for cULus approval: DC 35 V (DC 32 V with heavy-duty connector)
■ Current output (2-wire)4 ... 20 mA: DC 8 ... 36 V (DC 12 ... 36 V with optional
settling time of 1 ms)20 ... 4 mA: DC 8 ... 36 V
■ Voltage output (3-wire)DC 0 ... 10 V: DC 12 ... 36 VDC 0 ... 5 V: DC 8 ... 36 VDC 1 ... 5 V: DC 8 ... 36 VDC 0.5 ... 4.5 V: DC 8 ... 36 VDC 1 ... 6 V: DC 9 ... 36 VDC 10 ... 0 V: DC 12 ... 36 V
■ Ratiometric output (3-wire):DC 0.5 ... 4.5 V: DC 5 V ±10 %
Dissipation loss
■ Current output (2-wire)828 mW (22 mW/K derating of the dissipation loss with ambient temperatures ≥ 100 °C (212 °F))
■ Voltage output (3-wire)432 mW
Current supplyCurrent output (2-wire): Current signal, max. 25 mAVoltage output (3-wire): max. 12 mA
Time response
Signal type Settling time per IEC 62594 Signal dampingStandard 5) Option 1 6) 7) Option 2
Current (2-wire) 3 ms 1 ms 10 / 50 / 100 / 500 / 1,000 / 5,000 msVoltage (3-wire) 2 ms 1 ms 10 / 50 / 100 / 500 / 1,000 / 5,000 msRatiometric (3-wire) 2 ms 1 ms 10 / 50 / 100 / 500 / 1,000 / 5,000 ms
5) 3 dB limit frequency: 500 Hz6) 3 dB limit frequency: 1,000 Hz7) Alternative specifications for 4 ... 20 mA output signal:
Load: ≤ (power supply - 11.5 V) / 0.023 APower supply: DC 12 ... 36 V
Switch-on time150 ms
Switch-on drift5 s (60 s with optional zero point adjustment 0.1 %)
Page 4 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
Accuracy data
Non-linearity (per IEC 61298-2) Accuracy at calibration temperatureBFSL Terminal method
Standard ≤ ±0.25 % of span ≤ ±0.5 % of span ≤ ±0.5 % of spanOption 1 ≤ ±0.5 % of span ≤ ±1.0 % of span ≤ ±1.0 % of spanOption 2 ≤ ±0.125 % of span 8) ≤ ±0.25 % of span 8) ≤ ±0.25 % of span 8)
8) Restrictions for the non-linearity of 0.125 % BFSL or 0.25 % with terminal method:Available output signals: 4 ...20 mA and DC 0 ... 10 VAvailable measuring ranges: All measuring ranges specified in the data sheetFor further output signals or measuring ranges, please ask the manufacturer
Calibration temperatureStandard 15 ... 25 °C (59 ... 77 °F)Option 1 4 °C ±5 °C (39.2 °F ±41 °F)Option 2 40 °C ±5 °C (104 °F ±41 °F)Option 3 60 °C ±5 °C (140 °F ±41 °F)Option 4 80 °C ±5 °C (176 °F ±41 °F)
Zero point adjustmentStandard ≤ ±0.2 % of span, factory settingOption 1 ≤ ±0.1 % of span, factory setting 9)
Option 2 ±10 % of span, customer setting 10)
(stepwise 0.05 %)9) Restrictions for the zero point adjustment of 0.1% (factory setting):
Available output signals: 4 ...20 mA and DC 0 ... 10 VAvailable measuring ranges: All relative pressure measuring ranges specified in the data sheetNot available in combination with optional calibration temperatures.
10) The customer zero point adjustment is not available for all variants of electrical connection, see “Electrical connections”.
Relationship to the mounting positionFor measuring ranges < 1 bar (15 psi), an additional zero offset of up to 0.15 % applies
Non-repeatability≤ ±0.1 % of span
Temperature hysteresis0.1 % of span at > 80 °C (176 °F)
Long-term drift (per IEC 61298-2) ■ ≤ ±0.1 % of span ■ ≤ ±0.2 % of span (with special measuring ranges and measuring ranges < 1 bar (15 psi))
Temperature error (for calibration temperature 15 ... 25 °C (59 ... 77°F))For measuring ranges < 1 bar (15 psi), special measuring ranges and instruments with an increased overpressure limit the respective temperature error increases by 0.5 % of span
Medium temperature [°C]
Tem
pera
ture
erro
r [%
]
Page 5 of 13WIKA data sheet PE 81.61 ∙ 08/2014
Derating curve for cooling elements
Operating conditions
Permissible temperature ranges
Medium Ambient Design max. permissible pressure
Standard -30 ... +100 °C (-22 ... +212 °F) -30 ... +100 °C (-22 ... +212 °F) - -Option 1 -40 ... +125 °C (-40 ... +257 °F) -40 ... +125 °C (-40 ... +257 °F) - -Option 2 -40 ... +150 °C (-40 ... +302 °F) -40 ... +125 °C (-40 ... +257 °F) 11) with integrated cooling element 400 bar (5,800 psi)Option 3 -40 ... +200 °C (-40 ... +392 °F) -40 ... +125 °C (-40 ... +257 °F) 11) with integrated cooling element 400 bar (5,800 psi)Option 4 -20 ... +60 °C (-4 ... +140 °F) -20 ... +60 °C (-4 ... +140 °F) Oxygen application -Option 5 -20 ... +80 °C (-4 ... +176 °F) -20 ... +80 °C (-4 ... +176 °F) Performance level -
11) Derating curve and formula (see following diagram)
Depending on the choice of sealing on the process connection and the electrical connection, there may be limitations in the medium and the ambient temperatures (for restrictions see “Process connections, sealings” and “Electrical connections”).
Storage and transport conditionsPermissible temperature range: -40 ... +70 °C (-40 ... +158 °F)
Maximum humidity (per IEC 68-2-78):67 % r. h. at 40 °C (104 °F) (in accordance with 4K4H per EN 60721-3-4)
Climate classStorage: 1K3 (per EN 60721-3-1)Transport: 2K3 (per EN 60721-3-2)Operation: 4K4H (per EN 60721-3-4, without condensation
or icing)
Vibration resistance (per EC 60068-2-6)20 g, 10 ... 2,000 Hz(40 g, 10 ... 2,000 Hz for circular connector M12 x 1, metallic)
For instruments with cooling elements a limited vibration resistance of 10 g, 10 ... 2,000 Hz, applies
Continuous vibration resistance (per IEC 60068-2-6)10 g
Shock resistance (per EC 60068-2-27)100 g, 6 ms500 g, 1 ms for circular connector M12 x 1, metallic
EM field30 V/m (80 ... 1,000 Mhz)
Service life100 million load cycles (10 million load cycles for measuring ranges > 600 bar/7,500 psi)
Free-fall test (following IEC 60721-3-2)Individual packaging: 1.5 m (5 ft)Multiple packaging: 0.5 m (1.6 ft)PE bag: 0.5 m (1.6 ft)
0
25
50
75
100
125
150
25 50 75 100 125 150 175 200
Medium temperature [°C]
Ambi
ent t
empe
ratu
re [°
C]
Maximum permissible ambient temperatureTamb (Tmed < 125 °C) = 125 °CTamb (Tmed ≥ 125 °C) = -0.62 x Tmed + 202 °C
Tamb = Ambient temperature [°C]Tmed = Medium temperature [°C]
Maximum permissible medium temperatureTmed (Tamb < 80 °C) = 200 °CTmed (Tamb ≥ 80 °C) = -1.61 x Tamb + 326 °C
Page 6 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
Process connections
Available connections
Process connection per Thread size Maximum overpressure limit Optional pressure port 13)
EN 837 G ⅛ B 800 bar (11,600 psi)G ¼ B 12) 1,400 bar (20,300 psi) 0.3 mm / 0.6 mm / 6 mm 14)
(0.01 in / 0.02 in / 0.24 in 14))G ¼ female 1,400 bar (20,300 psi)G ½ B 12) 1,800 bar (26,100 psi) (1.4404)
3,200 bar (46,400 psi) (1.4542)0.3 mm / 0.6 mm(0.01 in / 0.02 in)
G ⅜ B 1,400 bar (20,300 psi)DIN 3852-E G ¼ A 12) 600 bar (8,700 psi) 0.3 mm / 0.6 mm
(0.01 in / 0.02 in)G ½ A 600 bar (8,700 psi) 0.3 mm / 0.6 mm / 12 mm 14)
(0.01 in / 0.02 in / 0.48 in 14))M14 x 1.5 600 bar (8,700 psi)
DIN 16288 M20 x 1.5 1,800 bar (1.4404)3,300 bar (1.4542)
M12 x 1.5 1,400 bar (20,300 psi)SAE J514 E 7/16-20 UNF BOSS 600 bar (8,700 psi) 0.3 mm / 0.6 mm / 6 mm 14)
(0.01 in / 0.02 in / 0.24 in 14))7/16-20 UNF J514 sealing cone 74°
1,100 bar (15,900 psi)
9/16-18 UNF BOSS 600 bar (8,700 psi)ANSI/ASME B1.20.1 ⅛ NPT 1,100 bar (15,900 psi)
¼ NPT 1,500 bar (21,700 psi) 0.3 mm / 0.6 mm / 6 mm 14)
(0.01 in / 0.02 in / 0.24 in 14))¼ NPT female 1,500 bar (21,700 psi)½ NPT 12) 1,500 bar (21,700 psi) (1.4404)
2,800 bar (40,600 psi) (1.4542)0.3 mm / 0.6 mm / 12 mm 14)
(0.01 in / 0.02 in / 0.48 in 14))KS PT ¼ 1,600 bar (23,200 psi) 0.3 mm / 0.6 mm / 6 mm 14)
(0.01 in / 0.02 in / 0.24 in 14))PT ½ 1,500 bar (21,700 psi)PT ⅜ 1,400 bar (20,300 psi)
ISO 7 R ¼ 12) 1,600 bar (23,200 psi) 0.3 mm / 0.6 mm / 6 mm 14)
(0.01 in / 0.02 in / 0.24 in 14))R ⅜ 1,500 bar (21,700 psi)R ½ 1,400 bar (20,300 psi) (1.4404)
2,840 bar (41,200 psi) (1.4542)12) For medium temperatures up to 150 °C (302 °F) or 200 °C (392 °F) available with cooling element.13) Pressure port 2.5 mm as standard14) Wider pressure port with 6 mm (0.24 in) or 12 mm (0.48 in) only feasible for measuring ranges up to and including 0 ...40 bar (0 ... 500 psi).
Other process connections on request.
Sealings
Process connection per
Copper Stainless steel NBR FKM FPM-40 ... +125 °C(-40 ... +257 °F)
-40 ... +125 °C(-40 ... +257 °F)
-20 ... +100 °C(-4 ... + +212 °F)
-15 ... +125 °C(-5 ... +257 °F)
-15 ... +200 °C(-5 ... +392 °F)
EN 837 Standard Option - -DIN 3852-E - - Standard Option OptionDIN 16288 Standard Option - -SAE J514 E - - Standard Option
Page 7 of 13WIKA data sheet PE 81.61 ∙ 08/2014
Electrical connections
Available connections
Electrical connection Ingress protection 16)
Wire cross-section
Cable ∅ Cable material
Permissible temperature
Angular connector DIN EN 175301-803 A 15)
with mating connector IP 65 max. 1.5 mm2 6 ... 8 mm - -30 ... +100 °C(-22 ... +212 °F)
with mating connector (conduit) IP 65 max. 1.5 mm2 - - -30 ... +100 °C(-22 ... +212 °F)
with mating connector with moulded cable
IP 65 3 x 0.75 mm2 6 mm PUR -30 ... +100 °C (cULus: -25 ... +85 °C)(-22 ... +212 °F (cULus: -4 ... +185 °F))
with mating connector with moulded cable, shielded
IP 65 6 x 0.5 mm2 6.8 mm PUR -25 ... +85 °C(-4 ... +185 °F)
Angular connector DIN EN 175301-803 C 15)
with mating connector IP 65 max. 0.75 mm2 4.5 ... 6 mm - -30 ... +100 °C (-22 ... +212 °F)with mating connector with moulded cable
IP 65 4 x 0.5 mm2 6.2 mm PUR -25 ... +85 °C(-4 ... +185 °F)
Circular connector M12 x 1 (4-pin) 15)
without mating connector IP 67 - - - -30 ... +100 °C(-22 ... +212 °F)
with mating connector, straight, with moulded cable
IP 67 3 x 0.34 mm2 4.3 mm PUR -25 ... +80 °C(-4 ... +176 °F)
with mating connector, straight, with moulded cable, shielded
IP 67 3 x 0.34 mm2 4.3 mm PUR -25 ... +80 °C(-4 ... +176 °F)
with mating connector, angled, with moulded cable
IP 67 3 x 0.34 mm2 5.5 mm PUR -25 ... +80 °C(-4 ... +176 °F)
Circular connector M12 x 1 (4-pin, metallic)without mating connector IP 67 - - - -40 ... +125 °C (cULus: +85 °C)
(-40 ... +257 °F (cULus: +185 °F))with mating connector, straight, with moulded cable
IP 67 3 x 0.34 mm2 4.3 mm PUR -25 ... +80 °C(-4 ... +176 °F)
with mating connector, straight, with moulded cable, shielded
IP 67 3 x 0.34 mm2 4.3 mm PUR -25 ... +80 °C(-4 ... +176 °F)
with mating connector, angled, with moulded cable
IP 67 3 x 0.34 mm2 5.5 mm PUR -25 ... +80 °C(-4 ... +176 °F)
Bayonet connector (6-pin)IP 67 - - - -40 ... +125 °C
(-40 ... +257 °F)Field case
IP 6K9K - 7 ... 13 mm - -25 ... +100 °C(-4 ... +212 °F)
Cable outletCable outlet IP 67 15) IP 67 3 x 0.34 mm² 5.5 mm PUR -30 ... +100 °C
(-22 ... +212 °F)Cable outlet ½ NPT conduit IP 67 6 x 0.35 mm² 6.1 mm PUR -30 ... +100 °C (cULus: +90 °C)
(-22 ... +212 °F (cULus: +194 °F))Cable outlet IP 68 IP 68 6 x 0.35 mm² 6.1 mm PUR -30 ... +125 °C (cULus: +90 °C)
(-22 ... +257 °F (cULus: +194 °F))Cable outlet IP 68, FEP IP 68 6 x 0.39 mm² 5.8 mm FEP -40 ... +125 °C (cULus: +105 °C)
(-40 ... +257 °F (cULus: +221 °F))Cable outlet IP 6K9K IP 6K9K 6 x 0.35 mm² 6.1 mm PUR -30 ... +125 °C (cULus: +90 °C)
(-22 ... +257 °F (cULus: +194 °F))Heavy-duty connectorwith mating connector with cable IP 68 6 x 0.14 mm2 6.5 mm PUR -40 ... +125 °C (cULus: -30 ... +90 °C)
(-40 ... +257 °F (cULus: -22 ... +194 °F))15)Customer zero point adjustment available as an option.16)Only applies when plugged in using a suitable mating connector that has the appropriate ingress protection
Other connections on request.
Page 8 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
Angular connector DIN 175301-803 A2-wire 3-wire
1
2
3
U+ 1 1U- 2 2S+ - 3Shield (option) 4 4
Angular connector DIN 175301-803 C2-wire 3-wire
U+ 1 1U- 2 2S+ - 3Shield (option) 4 4
Circular connector M12 x 1 (4-pin)2-wire 3-wire
4 3
1 2
U+ 1 1U- 3 3S+ - 4Shield (option) Case Case
Bayonet connector (6-pin)2-wire 3-wire
U+ A AU- B BS+ - CShield Case Case
Field case2-wire 3-wire
U+ 1 1U- 2 2S+ - 3Shield 5 5
Heavy-duty connector2-wire 3-wire
U+ 1 1U- 2 2S+ - 3Shield Case Case
Cable outlet2-wire 3-wire
U+ brown (BN) brown (BN)U- blue (BU) blue (BU)S+ - black (BK)Shield 1) grey (GY) grey (GY)
1) With cable outlet IP 67 and cable outlet ½ NPT conduit the shield is optional
Cable outlet (US code)2-wire 3-wire
U+ red (RD) red (RD)U- black (BK) black (BK)S+ - white (WH)Shield grey (GY) grey (GY)
Mating connector with moulded cable2-wire 3-wire
U+ brown (BN) brown (BN)U- blue (BU) blue (BU)S+ - black (BK)
Connection diagrams
Other pin assignments on request.
Electrical protective measuresThe electrical protective measures are not valid for ratiometric output signals.
■ Short-circuit resistance: S+ vs. U- ■ Reverse polarity protection: U+ vs. U- ■ Resistance to overvoltage: DC 40 V ■ Insulation voltage: DC 750 V
U+ Positive power supply terminalU- Negative power supply terminalS+ Analogue output
Assembly configurations of the cable outlets
Electrical connection Unfinished wire ends Tinned wire ends with end splicesCable outlet IP 67 Standard Option OptionCable outlet ½ NPT conduit - Option StandardCable outlet IP 68 - Option StandardCable outlet IP 68, FEP - Option StandardCable outlet IP 6K9K - Option Standard
Cable lengths of 2 m, 5 m, 6 ft or 15 ft are available, further cable lengths on request.
Page 9 of 13WIKA data sheet PE 81.61 ∙ 08/2014
Materials
Wetted parts ■ Relative measuring ranges:
- Measuring ranges ≤ 10 bar (150 psi): 316L- Measuring ranges > 10 bar (150 psi): 316L + 13-8 PH- Measuring ranges > 1,000 bar (10,000 psi): ASTM 630 and 13-8 PH
■ Absolute pressure measuring ranges: 316L ■ Sealing materials: See “Process connections”
Non-wetted parts ■ Case: 316 Ti
■ Zero point adjustment ring: PBT/PET GF30
■ Electrical connections:
- Angular connector DIN 175301-803 A: PBT/PET GF30
- Angular connector DIN 175301-803 C: PBT/PET GF30
- Circular connector M12 x 1 (4-pin): PBT/PET GF30
- Circular connector M12 x 1 (4-pin, metallic): 316L
- Bayonet connector (6-pin): 316L + Al
- Field case: 316L, 316Ti
- Heavy-duty connector: 316L
- Cable outlet IP 67: PA66, PBT/PET GF30
- Cable outlet ½ NPT conduit: 316L
- Cable outlet IP 68: 316L
- Cable outlet IP 68, FEP: 316L
- Cable outlet IP 6K9K: 316L
Pressure transmission fluidSynthetic oil (for measuring ranges < 10 bar (150 psi) gauge pressure, and all absolute pressure measuring ranges)
Options for specific media
Medium OptionFood Food-compatible transmission fluidOil and grease free Residual hydrocarbon: < 1,000 mg/m2
Packaging: Protection cap on the process connectionOxygen, oil and grease free Residual hydrocarbon (measuring range < 30 bar (435 psi)): < 500 mg/m2
Residual hydrocarbon (measuring range > 30 bar (435 psi)): < 200 mg/m2
Packaging: Protection cap on the process connection, instrument sealed in a PE bagMaximum permissible temperature -20 ... +60 °C (-4 ... +140 °F)
Elastomer sealing: Only FKM possible, max. -15 ... +60 °C (5 ... 140 °F) and max. 30 bar (435 psi) measuring range.
Not possible with process connections with female threadHydrogen On request
Measuring ranges: from 25 bar (362 psi) gaugeWetted parts: 316L and Elgiloy (2.4711)Maximum permissible temperature: -30 ... +30 °C (-22 ... +86 °F)
Page 10 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
with angular connector DIN EN 175301-803 A
with bayonet connector (6-pin)with angular connector DIN EN 175301-803 C
CE conformity
Pressure equipment directive97/23/EC
EMC directive2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)
Manufacturer’s declaration
RoHS conformity2011/65/EU
Performance level (per EN ISO 13849-1:2008)Performance level: PL = bCategory: Cat. = BDiagnostic coverage: DC = noneMTTF: > 100 yearsOperating temperature: -20 ... +80 °CFurther informations see safety manual on functional safety
Approvals
■ cULus, Safety (e. g. electrical safety, overpressure, ...), USA
■ GOST-R, import certificate, Russia ■ GOST, metrology/measurement technology, Russia
Certificates (option)
Available certificates2.2 test reportState-of-the-art manufacturingWetted metallic partsConfirmation of the class and indication accuracy3.1 inspection certificateWetted metallic partsWetted metallic parts with suppliers' certificateConfirmation of the class and indication accuracyList of single measured valuesDKD/DAkkS calibration certificate
Approvals and certificates, see website
Scope of delivery
Test report ■ Non-linearity 0.5 % ■ Non-linearity 0.25 % ■ Non-linearity 0.125 %
3 points5 points5 points
PackagingStandard Individual packagingOption Multiple packaging (up to 20 pieces)
Instrument labellingStandard WIKA label laseredOption Customer-specific label on request
DimensionsPressure transmitter model S-20
Weight: approx. 150 g (0.331 lbs) Weight: approx. 150 g (0.331 lbs)Weight: approx. 150 g (0.331 lbs)
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Page 11 of 13WIKA data sheet PE 81.61 ∙ 08/2014
with M12 x 1 circular connector(4-pin, metallic)
with field case
with circular connector M12 x 1 (4-pin)
with cable outlet IP 68, FEP, IP 6K9K
with heavy-duty connector
with cable outlet ½ NPT conduit
with angular connector DIN 175301-803 A and cooling element
with angular connector DIN 175301-803 A and zero point adjustment
with cable outlet IP 67
Weight: approx. 150 g (0.331 lbs)
Weight: approx. 290 g (0.639 lbs)
Weight: approx. 150 g (0.331 lbs)
Weight: approx. 220 g (0.485 lbs)
Weight: approx. 150 g (0.331 lbs)
Weight: approx. 220 g (0.485 lbs)
Weight: approx. 360 g (0.794 lbs) Weight: approx. 150 g (0.331 lbs)Weight: approx. 150 g (0.331 lbs)
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Dim
ensi
ons
in m
m
Page 12 of 13 WIKA data sheet PE 81.61 ∙ 08/2014
G L1G ¼ A 14 (0.55)G ½ A 17 (0.67)M14 x 1.5 14 (0.55)
G L1G ¼ B 13 (0.51)G ½ B 20 (0.79)G ⅜ B 16 (0.63)M12 x 1.5 15 (0.59)M20 x 1.5 20 (0.79)
G L1⅛ NPT 10 (0.39)¼ NPT 13 (0.51)½ NPT 19 (0.75)PT ¼ 13 (0.51)PT ½ 19 (0.75)PT ⅜ 15 (0.59)R ¼ 13 (0.51)R ½ 19 (0.75)R ⅜ 15 (0.59)
G D1 L1 L2 L3G ¼ female
25(0.95)
20(0.79)
13(0.51)
10(0.39)
G L17/16-20 UNF J514 sealing cone 74°
15 (0.59)
G L1G ⅛ B 10 (0.39)
G L17/16-20 UNF BOSS 12.06 (0.47)9/16-18 UNF BOSS 12.85 (0.51)
G D1 L1 L2¼ NPT female
25(0.98)
20(0.79)
14(0.55)
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
Process connectionsDimensions in mm (inch)
Page 13 of 13WIKA data sheet PE 81.61 ∙ 08/2014
WIKA Alexander Wiegand SE & Co. KGAlexander-Wiegand-Straße 3063911 Klingenberg/GermanyTel. +49 9372 132-0Fax +49 9372 [email protected]
08/2
014
GB
© 2013 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing.We reserve the right to make modifications to the specifications and materials.
Ordering informationModel / Measuring range / Overpressure limit / Output signal / Non-linearity / Calibration temperature / Zero point adjustment / Process connection / Pressure channel / Sealing / Electrical connection / Assembly / Cable length / Shielding / Certificates / Packaging / Instrument labelling / Accessories and spare parts
Accessories and spare parts
Mating connector
Designation Order no.without cable with 2 m (6 ft) cable with 5 m (16 ft) cable with 2 m (6 ft) cable,
shieldedAngular connector DIN EN 175301-803 A
■ with cable gland, metric 11427567 11225793 11250186 14100465 ■ with cable gland, conduit 11022485 - - -
Angular connector DIN EN 175301-803 C 1439081 11225823 11250194 -Circular connector M12 x 1 (4-pin)
■ straight - 11250780 11250259 14056584 ■ angled - 11250798 11250232 -
Sealings for mating connectors
Mating connector Order no.Blue (WIKA) Brown (neutral)
Angular connector DIN EN 175301-803 A 1576240 11437902Angular connector DIN 175301-803 C 11169479 11437881
Sealings for process connection
Thread size Order no.Copper Stainless steel NBR FKM FPM
G ⅛ B 11251051 - - - -G ¼ B 11250810 11250844 - - -G ½ B 11250861 11251042 - - -G ⅜ B 11250861 - - - -M12 x 1.5 11250810 11250844 - - -M20 x 1.5 11250861 11251042 - - -G ¼ A - - 1537857 1576534 1576534G ½ A - - 1039067 1039075 -M14 x 1.5 - - 1537857 1576534 -7/16-20 UNF BOSS - - 14057554 11472022 -9/16-18 UNF BOSS - - 14057555 2063240 -