Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

HAMON GROUP

Global Presence in Air Quality systems

Page 2: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

Hamon Companies

– Hamon & Cie is a Belgium based global group specializing in pollution control, heatrecovery and cooling technologies for the utility, petrochemical and heavyindustries, with annual turnover of over $700 million.

– Hamon has operating companies in Europe, Asia, Africa, South America and USA.

Integrated solutions for a clean environment

Page 3: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality SystemsHamon Air Quality SystemsCooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

2

HAMON RESEARCH COTTRELL INDIA ( HRC INDIA )

THANK

For Inviting us for the ROUND TABLE CONFERENCEON

Pollution Control Technology Options for coal fired Boilers

Page 4: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

MOEF NORMS

Page 5: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

There are definite Challenges for coal fired power producers/ plant owners to comply with thenew Environment guidelines, both with respect to particulate matter emission , as will as gaseousemissions.

The challenges has to be dealt separately for

- Existing plants- New Plants

Existing Plants

- Is there space for adding additional ESP fields. For instance , let us consider the presentemission levels in the range of 600mg/nm3 , to bring down the level to 100mg/nm3 we need toadd 2 fields in each of the gas passage.

- Is the present ESP performing to its designed condition. Because most of the ESP’s installed inIndian power plant during the last 10 – 15 years have been designed for emission of 50mg/nm3or even less.

Challenges

Page 6: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

Though the ESP’s installed in Indian power plants are significantly bigger than else were inthe world ( Indian 660 MW ESP : 54 to 60 fields ; outside India 660 MW : 32 fields ) , stillmany ESP’s are not performing to its design condition.

ESP in the existing plant are not performing due to one or more of the following reasons

- Hopper Level switches bypassed , Ash level build up . Certain cases up to 60% of the heightof CE. Even though the Ash is evacuated , the Electrodes get permanent deformation ,misaligned.

- Rapping system not properly maintained.- Seal Air system not properly maintained. This causes the dust to get accumulated in the

Insulator , leading to crack.- Old type of controllers.

Addressing the above points , combined with field addition ( series or parallel ) is the onlysolution for the existing plants.

Challenges

Page 7: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

New coal fired Power Plants :

• Most of the new Tender released for Utility plants go with an guaranteed outlet emissionof less than 17mg/nm3.

• Globally ( Europe & USA ) , For coal fired boilers , Fabric Filter is also considered as solutionfor achieving low emissions on sustained basis.

• Another advantage of Fabric Filter is that it is not sensitive to the type of fuel , inlet dustloading etc.

• Capital cost is comparatively low when compared to an ESP , but more operational costwith respect to power consumption of the ID fan , and replacement of bags every 3 years.

• Fabric available to operate in wide range of elevated temperature.

POSSIBLE SOLUTION/OPTION AVAILABLEParticulate Matter

Page 8: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

Low Pressure Pulse Jet FF – 2x 1000 MW coal fired Boiler

Page 9: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

HAMON TECHNOLOGIES : COMBINED SOLUTION FOR PARTICULATE MATTER & SOX

Hamon have a specialised semi dry Flue Gas desulphurisation technology called Circulatingfluidised bed FGD or Circulating Dry Scrubber

Page 10: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

· Desulphurization efficiency above 99 % can beachieved

· Availability of over 98 % can be achieved· Simple and reliable process· No pre-dedusting of boiler ash needed· No limitations on SO2/SO3 concentrations;

desulphurization efficiency > 99% possible· Complete SO3, therefore no need for any

special material for corrosion protection· Multi pollution removal technology (heavy

metals, dioxins and furans, particles PM10)· Low space requirements· Lower investment costs than others· Dry FGD product· No reheating of cleaned flue gases necessary· No scale up limitations· Unlimited part load performance due to clean

gas recirculation

Page 11: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality SystemsHamon Air Quality SystemsCooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

PLAN View

2 x 360 MW CDS FGD – UnderExecution

Page 12: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

5/07/2016

HAMON TECHNOLOGIES : MULTIPOLLUTANT SOLUTION FOR SOX ,NOX ANDMERCURY

Hamon have a advanced integrated Multi-Pollutant control Technology called ReACT

Page 13: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

§ Fully dry process based on moving bed adsorption on activated coke§ No water evaporated into flue gas, (water usage at 1% of WFGD, DFGD)§ No sprays, no wet/dry interface, no moist material fouling, no slurry preparation§ No increase in water vapor plume, no acid plume

§ SO2 and acid gases§ >>95% SO2 control§ Near zero SO3 emission§ Carbon steel flue gas path including stack

§ NOx control design options§ Co-benefit NOx control at 20-40%§ Enhanced NOx control to 40-60% with NH3 dosed AC regeneration§ Higher NOx control to 80% available with two-stage adsorption

§ Hg control with waste volume minimization§ 95% control of both elemental and oxidized forms as co-benefit§ Hg waste volume minimized (<0.1 ton/MW/year)

§ Regenerative system for activated coke adsorbent§ Reduced reagent and disposal material volume§ Sulfur rich gases are feedstock to production of byproduct sulfuric acid

§ Operational through start-up and shutdown§ Flue gas is treated over 100% of the boiler operation

§ Well suited as retrofit technology§ Installation downstream reduces station outage requirements§ Dry operation allows use of existing stack/liners

Salient Points - ReACT

Page 14: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

DUSTREMOVALSYSTEM

Hybrid Collectors(COPHAC)

Cyclone &Multicyclones

Flue Gas ConditioningNH3, SO3

Fabric FiltersPulse jet and Low pressure

Air Quality System – Product atglance

Dry & WetElectr. Precipitators

ACID GASREMOVALSYSTEMS

Dry type FGT Systems

Semi-Dry FGT Systems

Wet FGD scrubbing forInd’l Boilers and Diesel Engines

Seawater FGD

Circulated Fludized BedFGD

Wet limestone FGD

NOxREMOVALSYSTEMS

SCR DeNOxsystems

NOx and COcatalyst SCR

U2A – Urea toAmmonia System

MULTI-POLLUTANTSSYSTEM andSPECIALAPPLICATIONS

Wet FGD Exxon processfor FCCU*

ReACT Process*

UREA Scrubbers

Combinated FGT System

Metals Control

Combinated FGT Systemfor Dioxines and Heavy

Metals Control

Page 15: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

Industries we serve

15

Power Generation

Steel & Foundry

Petrochemicals

Non-ferrous Metals

Cement

Glass Pulp & Paper

Fertilisers

Refining

Page 16: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems Presence in India

5/07/2016

HAMON RESEARCH COTTRELL INDIA PVT. LTD. (HRC INDIA) an ISO9001:2008 is wholly ownedcompany and member of the Air Pollution Control division of the world wide HAMON Grouphaving its head quarters in Belgium.

Formed in July 2011 , Prior to the formation ; Hamon was operating through their licensee'snamely - Voltas , and ACC and joint venture company Hamon Shriram Cottrell.

HRC INDIA is the Engineering center for Hamon AQS business unit.

Employee strength is 130 . Registered office at Chennai , and branch office at Kolkata.

Sales Representations at Mumbai & Delhi.

The company in house resources are primarily engineer's who develop, plan, design, installand service equipment.

Page 17: Hamon Air Quality Systemscdn.cseindia.org/userfiles/ESP-performance-Vs-design-by-hammon... · Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat

Cooling Systems Air Quality Systems Process Heat Exchangers Chimneys HRSG & Waste Heat Boilers

Hamon Air Quality Systems

M. VALLINAYAGAM : Director & CEO ( HAMON INDIA )Contact Number : +91 49090500

Email : [email protected]_______________________________________________________________

For information about Product & Sales

R.Singaravelu – Addnl General Manager ( HAMON INDIA )+91 44 49090573 ; +91 9840979863

[email protected]

_____________________________________________________________________Registered office AddressHamon Research- Cottrell India Private limitedRR Tower V , 5th Floor , Plot No – 33 AThiru-Vi-Ka Industrial Estate , GuindyChennai – 600032Tel : +91 44 49090500 , Fax : +91 44 49090550

Contact – HAMON