GPD Soctland

Embed Size (px)

Citation preview

  • 7/28/2019 GPD Soctland

    1/83

    FORWARD | CONTENTS | CLOSE

    Circular 1/201Guidance onHouseHolder permitteddevelopment riGHts

    2

  • 7/28/2019 GPD Soctland

    2/83

    02

    contents

    FORWARD|BACK | CLOSE

    1. INTRODUCTION 04

    2. BEFORE STARTING 05

    3. MAIN CONCEPTS 07Principal elevation 08Fronting a road 11Front and rear curtilages 14Site coverage 15Original or existing dwellinghouse 16Heights and Ground Levels 16

    4. MAkING ChANGES TO A DwEllINGhOUSE 17Single storey ground oor extension 20Ground oor extensions o more than one storey 25

    Porch 29Enlargement o the roo 31Access ramps 36Improvements or alterations that are not an enlargement, including replacement windows,solar panels, ues and satellite dishes 38Ancillary buildings including sheds, garages, greenhouses etc. 43Any building, engineering, installation or other operation 46Hard surace 50Decking or other raised platorm 52Gates, ences, walls or other means o enclosure 55

    5. MAkING ChANGES TO A FlAT 57Improvements or alterations that are not an enlargement, including replacement windows,solar panels, ues and satellite dishes 57Gates, ences, walls or other means o enclosure 60

    6. INSTAllING MICROGENERATION EqUIPMENT 62

    7. INSTAllING ClOSED CIRCUIT TElEvISION (CCTv) 77

    8. ThINGS TO CONSIDER 79

    9. GlOSSARy 80

  • 7/28/2019 GPD Soctland

    3/83

    03

    FORWARD | BACK | CONTENTS | CLOSE

    PlANNING SERIES

    Scottis Panning Poic (SPP)is the statement o Scottish Government policy on nationally

    important land use planning matters.

    Nationa Panning Frameor (NPF)is the Scottish Governments strategy or Scotlandslong term spatial development.

    Circuarscontain Scottish Government policy on the implementation o legislation or

    procedures.

    Statements o Scottish Government policy in the SPP, NPF and Circulars may be material

    considerations to be taken into account in development plans and development management

    decisions.

    Designing Places and the West Edinburgh Planning Framework have the same status in

    decision making as the SPP and NPF.

    Panning Adice Notes (PANs) provide advice and inormation on technical planning matters.

    Further inormation on the Scottish Governments role in the planning system is available on

    http://www.scotland.gov.uk/Topics/Built-Environment/planning.

  • 7/28/2019 GPD Soctland

    4/83

    04

    FORWARD | BACK | CONTENTS | CLOSE

    1.7

    Planning authorities can oer help and advice

    A list o planning authorities can be ound

    on the planning section o the ScottishGovernment website www.scotland.gov.uk

    Additiona Approas Reuired

    I planning permission is not required, there

    are sometimes other approvals that may be

    required. For example, approval under the

    building regulations rom the local council

    may be required. It is or the individual to

    ensure that their development complies withrelevant legislation. The most requent are

    detailed within Section 2.

    1. introduction

    1.1

    Developments can have a signifcant impact

    on a neighbourhood and the environment.

    1.2

    Submitting a planning application gives an

    opportunity or the proposed development to

    be considered in its local setting. However,

    considering applications or minor and

    uncontroversial developments is not an

    efcient way o regulating development.

    1.3Permitted development rights are granted so

    that many instances o small alterations and

    extensions can be carried out without the

    need to submit an application or planning

    permission.

    1.4

    The purpose o this document is to explain

    householderpermitted development rights andthereore what can be built without submitting

    a planning application.

    1.5

    Section 2 provides general advice that should

    be considered beore starting work.

    1.6

    Section 3 explains the main concepts used

    within the planning legislation. It is necessary

    to understand these concepts so that the

    household classes to which they relate can

    be correctly applied. Sections 4 - 7 provide

    detailed advice on how the rules should be

    applied. Further guidance can be ound at

    www.scotland.gov.uk/householderdevelopment

    http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttps://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planning
  • 7/28/2019 GPD Soctland

    5/83

    05

    FORWARD | BACK | CONTENTS | CLOSE

    2. BeFore startinG

    2.1

    Home improvement projects, such as an

    extension, should be careully considered. Time

    spent planning can save money. It can alsoensure the work is completed on time and as

    required. It is the property owners responsibility

    to ensure that the relevant statutory

    requirements are met. I the development ails to

    comply with the relevant legislation, the owner is

    liable or any remedial action (which could go as

    ar as demolition and restoration).

    2.2The position, design and scale o householder

    developments can help maintain the character

    o neighbourhoods. These can also help

    reduce the impact on the wider environment

    and local biodiversity. Some developments can

    make homes more sustainable by helping to

    reduce energy use, whilst the installation o

    microgeneration equipmentcan help generate

    energy and reduce costs.

    2.3

    Most planning authorities oer advice on

    how the rules apply, as well as advice on the

    relevant processes and procedures. Furtherguidance or planning and building regulations

    is also available rom www.scotland.gov.uk/

    householderdevelopment.

    http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/householderdevelopmenthttp://www.scotland.gov.uk/householderdevelopmenthttp://www.scotland.gov.uk/householderdevelopmenthttp://www.scotland.gov.uk/householderdevelopmenthttp://www.scotland.gov.uk/householderdevelopmenthttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planning
  • 7/28/2019 GPD Soctland

    6/83

    06

    FORWARD | BACK | CONTENTS | CLOSE

    2. BeFore startinG

    Buiding Standards: the proposed work will likely require to comply with minimumbuilding standards. A building warrant may also be required beore you start the work, you

    can veriy this with your local authority building standards department.

    lega position: check the legal position to ensure that there are no restrictions on the

    land or the type o work (or example Article 4 directions removing permitted development

    rights, legal title or rights o way). You may wish to consult a proessional such as a

    planning consultant or solicitor.

    Panning istor: planning permission granted in the past may have a condition or other

    restriction prohibiting the kind o work proposed. I in doubt check with your planning

    authority.

    listed Buidings and Conseration Areas:Listed Building Consent may be needed

    i you live in a listed building. I you live in a conservation area you may need to apply or

    planning permission. I in doubt check with your planning authority.

    Scedued Monuments:Work proposed in or near a scheduled archaeological site

    should be planned to avoid direct impact on the monument and impacts on its setting

    minimised, where sites are not scheduled certain precautions may be required. I in doubt

    check, or scheduled monuments check with Historic Scotland and or unscheduled sites

    with your planning authority. Oter Consents: Check that the proposed work does not require a consent or approval

    such as a road or advertisementconsent or is causing an obstruction.

    Oter tings to consider: a range o other issues like biodiversity, water mains and old

    mine works are detailed in Section 8.

    ThINGS TO ChECk

    http://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htmhttp://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htmhttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htmhttp://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htmhttp://www.environment.scotland.gov.uk/http://www.historic-scotland.gov.uk/index/heritage/searchmonuments.htmhttp://www.historic-scotland.gov.uk/index/heritage/searchmonuments.htmhttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.historic-scotland.gov.uk/index/heritage/searchmonuments.htmhttp://www.environment.scotland.gov.uk/http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htmhttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.historic-scotland.gov.uk/index/heritage/historicandlistedbuildings.htm
  • 7/28/2019 GPD Soctland

    7/83

    07

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    3.1

    This section explains in detail the concepts

    that are undamental to interpreting and

    applying the legislation. These concepts are: Principal Elevation a term used to identiy

    the ront o the dwellinghouse

    Fronting a Road is a way o determining i

    the principal elevation, or side elevation, is

    in the public domain

    Front and Rear Curtilageis a way

    o defning the area o land used or

    the comortable enjoyment o thedwellinghouse

    Site Coverage is used to control the

    overall amount o ground covered by

    development

    Original or Existing Dwellinghouse. The

    original dwellinghouse is the dwellinghouse

    as built or as it was on 1 July 1948 i

    it was built beore then. The existing

    dwellinghouse is the house immediately

    beore carrying out the proposed

    development

    Height and Ground Level. How the height

    o development is measured

  • 7/28/2019 GPD Soctland

    8/8308

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Principa Eeation

    3.2

    The term principal elevation is used to identiy

    the ront o a dwellinghouse. Whilst there are

    exceptions, most dwellinghouses are designed

    so that the ront o the dwellinghouse aces

    a road.

    3.3

    Having established the principal elevation, the

    rear elevation will be the elevation opposite

    the principal elevation. Side elevations will link

    the principal and rear elevation.

    Defnition

    3.4

    The principal elevation is a reerence to the

    elevation o the original dwellinghouse which

    by virtue o its design or setting, or both, is the

    principal elevation. Where it is not immediately

    obvious, a combination o the ollowing actors

    should be used to identiy the principal

    elevation:

    location o main door

    windows

    relationship to road

    boundary treatment

    architectural ornamentation

    3.5

    It is unlikely that any single actor will be

    decisive. The identifcation o the principal

    elevation should not be used to controldevelopment. There can only be one principal

    elevation. It is based on the design o the

    original dwellinghouse.

    3.6

    Figures 1-4 on pages 9-10 illustrate how the

    principal elevation can be identifed in a variety

    o common situations.

  • 7/28/2019 GPD Soctland

    9/8309

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Figure 1: In this example the principal

    elevation is the elevation that ronts the

    road. It has the main door and is the obviousorientation o the dwellinghouse. The side

    elevation has no windows and has a shorter

    length. The rear area is more private with a

    higher ence.

    Figure 2: In this example the side elevation

    has the main door and a longer length, it

    has only a secondary window. The windowsin the principal elevation show the main

    orientation o the dwellinghouse and it

    ronts the road. The boundary treatment

    indicates a more private rear area.

    Figure 3: In this example the dwellinghouse

    on the corner plot will ace two roads.

    However, the principal elevation has themain door and ronts the same road as

    the adjacent dwellinghouse. Opposite the

    principal elevation is the private rear area.

    The side elevation - although ronting a road

    and having windows - does not reect the

    main orientation o the dwellinghouse.

  • 7/28/2019 GPD Soctland

    10/8310

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Figure 4: In this example o a Radburn-

    type layout the principal and rear elevations

    could be identical. However, the overallsetting and boundary treatment indicates

    which elevation would be understood as

    the ront and rear. The side elevation has

    windows and aces a road but is not the

    principal elevation.

  • 7/28/2019 GPD Soctland

    11/8311

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Fronting a Road

    3.7

    It is important to determine the relationship

    o the principal and side elevation to a road.

    In the context o the householder permitted

    development rights, Frontsmeans acing

    onto a road and applies to both the principal

    and side elevation. It is determined by a

    number o actors including the angle o

    the dwellinghouse to the road, the distance

    between the dwellinghouse and the road and

    the size o any intervening land.

    3.8

    Fronting is used in a number o classes as

    a way o restricting permitted development.

    Development is oten not permitted i any part

    o the development would be orward o a wall

    orming part o the principal elevation or side

    elevation.

    3.9As illustrated in fgures 5 and 6, an imaginary

    line can be drawn that extends rom the

    principal elevation or side elevation to the

    boundary, this is the land orward o the

    principal elevation or side elevation.

    3.10

    Whilst fgures 5 and 6, illustrate this concept

    in common circumstances, there will be

    situations where neither the principal nor theside elevation ront a road. In such cases,

    development orward o a wall orming part

    o the principal elevation or side elevation

    may be permitted development subject to

    compliance with other criteria in any given

    class. Figures 7-11 illustrate situations where

    the principal elevation may not ront a road.

    Figure 5

    Figure 6

  • 7/28/2019 GPD Soctland

    12/83

    12

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Figure 9: As the road bends, the side

    elevation no longer ronts the road. Any

    extension within the hatched areas wouldrequire a planning application to the

    planning authority.

    Figure 7: Where there is no road. In this

    example, development would be permitted

    within any part o the curtilage o thedwellinghouse at the top o the diagram as

    long as it meets the site coverage, distance

    rom boundary, height restrictions any

    other relevant restrictions or the type o

    development.

    Figure 8: Where the dwellinghouse is

    sited at an angle. I an elevation is sited at

    a very acute angle to a road, it may not beconsidered to ront a road. In this illustration

    the dwellinghouse is judged to ront a road.

    Any extension within the shaded areas

    would require a planning application to the

    planning authority.

  • 7/28/2019 GPD Soctland

    13/83

    13

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Figure 11: I there is intervening land between the curtilage o a dwellinghouse and a road,

    it could no longer be argued as ronting the road. In this example, any development would

    be permitted within the curtilage o the development as long as i t meets the site coverage,distance rom boundary, height restrictions and any other relevant restrictions or the type o

    development.

    Figure 10: Within 20 metres o a road it is

    considered unlikely that any elevation could

    be argued to be too ar rom a road so thatit no longer ronts a road. Beyond

    30 metres rom a road, it is increasingly

    likely that an elevation no longer ronts a

    road. For distances in between, a judgement

    would have to be made depending on act

    and degree. This will involve considering

    actors such as topography, landscaping

    and layout o any adjacent properties. In

    this example, any developments would

    be permitted within the curtilage o thedevelopment as long as it meets the

    site coverage, distance rom boundary,

    height restrictions and any other relevant

    restrictions or the type o development.

    50metres

  • 7/28/2019 GPD Soctland

    14/83

    14

    FORWARD | BACK | CONTENTS | CLOSE

    3. main concepts

    Front and Rear Curtiages

    3.11

    Once the principal elevation has been

    identifed, the ront and rear curtilages canbe defned. The ront curtilage is all the land

    orward o the principal elevation. The rear

    curtilage is the remainder o the curtilage

    o the original dwellinghouse. This may not

    reect any physical division, like ences, that

    may exist.

  • 7/28/2019 GPD Soctland

    15/83

    FORWARD | BACK | CONTENTS | CLOSE

    Propo

    sal

    Rear

    Front

    15

    3. main concepts

    A Original dwellinghouse includingan integral garage built beore 1948

    C A conservatory granted planningpermission in 1996

    E A greenhouse builtbeore 1948

    B An extension built as permitteddevelopment in 1968

    D A swimming pool built aspermitted development in 1975

    Figure 12: Cacuating Site Coerage

    In this example the total developed area comprises: the extension (B); conservatory (C) and

    swimming pool (D) since these developments occurred since 1948 , together with the greenhouse(E) as it was not attached to the original dwellinghouse.

    Thereore, in this example

    % o site coverage = Area o B + C + D + E + Proposal

    Area o rear curtilage minus A*1x 100

    I the site coverage will be more than 50%, o the rear curtilage in this example, planning

    permission is required.

    *1Includes any hard surace or deck.

    Site Coerage

    3.12

    The size o any proposed extension, shed

    or other building must be such that the totalarea undeveloped is at least hal o the rear or

    ront curtilage. This is explained in fgure 12.

    In most circumstances, the limitation will only

    relate to the rear curtilage. Where the principal

    or side elevation does not ront onto a road,

    the limitation could also apply to the ront

    curtilage.

    3.13

    There is also a restriction to ensure that the

    total area covered by all extensions (including

    previous extensions) is not greater than the

    area covered by the original dwellinghouse.

  • 7/28/2019 GPD Soctland

    16/83

    FORWARD | BACK | CONTENTS | CLOSE

    16

    3. main concepts

    Origina or Existing Deingouse

    3.14

    It is important to dierentiate between the

    original dwellinghouse and the existingdwellinghouse.

    3.15

    The original dwellinghouse is the

    dwellinghouse as built or as it was on 1 July

    1948 i it was built beore then.

    3.16

    The existing dwellinghouse is thedwellinghouse immediately beore carrying

    out the development proposal that is being

    assessed. It does not include any outbuildings,

    even where they were built at the same time

    as the original dwellinghouse.

    heigts and Ground lees

    3.17

    For the purposes o Classes 1A to 3E o the

    General Permitted Development Order, theheight o the development is measured rom

    the lowest part o the surace o the ground

    adjacent to the building or structure.

    3.18

    In all other instances the height o the building

    or structure is calculated rom the highest

    part o the surace o the ground immediately

    adjacent to the building or structure.

    3.19

    The ground is the natural ground and would

    not include any addition laid on top o the

    natural ground.

    Height

    Ground line

  • 7/28/2019 GPD Soctland

    17/83

    17

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse

    4.1

    The relevant permitted development rights or

    the main types o householder developments

    are explained within this section.

    4.2

    Permitted development rights or the dierent

    types o development are described within a

    class. Most classes are subject to limitation

    and restrictions. The main householder classes

    are grouped into the ollowing categories:

    >Enlarging a dwellinghouse

    >Improvements, additions or other

    alterations to a dwellinghouse that are

    not an enlargement

    >Other developments within the curtilage

    o a dwellinghouse

    4.3

    Permitted development rights or ats are

    detailed in Section 5.

    4.4

    Section 6 details permitted development

    rights or microgeneration and Section 7

    details the regulations or CCTV.

    4.5

    All the limitations within a class must

    be complied with. In addition, permitted

    development rights are removed i theproposed development is to create or

    materially widen a means o access to a

    trunk road or classifed road or creates an

    obstruction that is likely to causes a hazard or

    people using the road.

  • 7/28/2019 GPD Soctland

    18/83

    18

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouses introduction to enlarGinG a dwellinGHouse

    Introduction to Enarging aDeingouse

    4.6

    It is important to understand the defnition

    o enlargement. Enlargement is defned as

    any development that increases the internal

    volume o theoriginal dwellinghouseand

    includes a canopy or roo, with or without

    walls, which is attached to the dwellinghouse,

    but does not include a balcony. Thereore, a

    car-port is an enlargement but a balcony is

    not.

    4.7

    There are many types o enlargements. The

    ollowing 4 classes cover the most common

    types o enlargements or dwellinghouses.

    Singe store ground foor extension

    Class 1A Any enlargement o a

    dwellinghouse by way o a single storey

    ground foor extension, including anyalteration to the roo required or the

    purpose o the enlargement.

    This class covers the typical single storey

    extension to the rear o the property. Typical

    developments include conservatories, car-

    ports as well as other canopies or roos,

    with or without walls.

    Ground foor extension o more tan

    one store

    Class 1B Any enlargement o a

    dwellinghouse by way o a ground foorextension consisting o more than one

    storey including any alteration to the

    roo required or the purpose o the

    enlargement.

    This class covers the typical 2 storey

    extension. The limitations set a minimum

    distance o 10 metres between the

    extension and any boundary, since many1 storey and 2 storey extension are more

    likely to have a greater impact than a single

    storey extension. It is recognised that the

    majority o extensions will not be able to

    meet this criteria, thereore an application

    or planning permission would be required

    in most instances.

    https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/
  • 7/28/2019 GPD Soctland

    19/83

    19

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse introduction to enlarGinG a dwellinGHouse

    Porc

    Class 1C The erection, construction or

    alteration o any porch outside any external

    door o a dwellinghouse.

    This class allows or the construction o a

    small porch on any external door.

    Enargement o te roo

    Class 1D Any enlargement o a

    dwellinghouse by way o an addition or

    alteration to its roo.

    This class allows or the construction o a

    typical rear acing dormer.

    4.8

    These permitted development rights do NOT

    apply to ats.

    4.9

    I the proposed development alls into any o

    the above classes and is in a conservation

    area then an application to the planning

    authority is required.

    4.10

    A listed building consent is required i the

    proposed development aects the characteror setting o a listed building. A building

    warrant rom the local authority is also oten

    required, as explained in Section 2.

    http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planning
  • 7/28/2019 GPD Soctland

    20/83

    20

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse sinGle storey Ground Floor extensions

    Singe store ground foorextensions

    SUMMARy

    4.11

    This is the most popular type o development.

    Permitted development rights al low the

    enlargement o a dwellinghouse by a single

    storey ground oor extension. The permitted

    development rights allow any alteration to

    the roo required or the purpose o the

    enlargement. In summary, the eect o the

    limitations is that:

    extensions are generally located to the rear

    i the extension is on, or within 1 metre o

    the boundary, it cannot project, rom the

    rear wall o the existing dwellinghouse, by

    more than 3 metres in the case o terraced

    house, or 4 metres in all other cases

    the height o the eaves is a maximum o

    3 metres

    the height o the extension is not higher

    than 4 metres

    the ootprint o the extension is no larger

    than the original dwellinghouse or covering

    more than hal the curtilage

    4.12

    There are no permitted development rights

    or single storey ground oor extensions in

    conservation areas or or ats. Listed building

    consent will normally be required i your

    building is Listed.

    4.13

    A building warrant rom the local authority willlikely be required or this type o extension, as

    explained in Section 2.

  • 7/28/2019 GPD Soctland

    21/83

    21

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse sinGle storey Ground Floor extensions

    TEChNICAl EXPlANATION

    4.14I the extension exceeds any o the ollowing

    limits then an application or planning

    permission is required.

    4.15

    Roo alterations relating to the extension

    are also permitted. Other roo alterations

    should be carried out using the other relevant

    permitted development classes.

    4.16

    The extension cannot be orward o a wall

    orming part o the principal elevation or side

    elevation i that elevation is ronting a road.

    The identifcation o the principal elevation and

    side elevations are discussed in paragraphs

    3.2 3.6, whilst ronting a road is discussed at

    3.7 3.10. This is illustrated in fgure 13.

    Figure 13: The shaded areas o the curtilage indicate where a single storey extension is

    permitted as long as the other limitations are met.

  • 7/28/2019 GPD Soctland

    22/83

    22

    FORWARD | BACK | CONTENTS | CLOSE

    4.0m

    4.0m

    6.0m

    2.0m

    4.0m

    5.0m

    1.0m

    4. makinG cHanGes to a dwellinGHouse sinGle storey Ground Floor extensions

    4.1

    I any part o the extension is within 1 metre

    o the boundary o the curtilage, it can only

    project rom the line o the rear elevationnearest to the boundary by 3 metres i a

    terraced house or 4 metres in any other case.

    4.18

    This restriction does not apply to a side

    extension that does not project beyond the

    line o the rear elevation. For example i a sideextension, does extend beyond the line o the

    rear wall and is within 1 metre o the

    boundary, then it cannot project rom the

    rear wall nearest the boundary by more than

    3 metres i a terraced house or 4 metres inany another case.

    7

  • 7/28/2019 GPD Soctland

    23/83

    23

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse sinGle storey Ground Floor extensions

    4.19

    The overall height o an extension can have a

    signifcant impact on neighbours. Theeaveso

    the extension cannot be higher than 3 metres.The overall height o the extension cannot

    exceed 4 metres.

    4.20

    When measuring the height o the extension

    on sloping, or uneven ground, the height

    should be measured rom the lowest point

    immediately adjacent to the extension.

    4.21

    The area covered by all extensions, including

    any existing and the proposed extension,

    cannot be greater than the ootprint o theoriginal dwellinghouse. This is to ensure that

    the extension (including previous extensions)

    is in proportion to the original dwellinghouse.

    4.22

    The proposed extension (including previous

    extensions) and existing developments

    cannot exceed hal o the o the rear (or

    ront i appropriate) curtilage o the originaldwellinghouse. This is explained urther in

    paragraphs 3.12 3.13.

    4.23

    There are no Class 1A permitted development

    rights in a conservation area or or ats.

    A listed building consent is required i theproposed extension aects the character or

    setting o a listed building.

    4.24

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listed

    buildings is available rom http://www.historic-

    scotland.gov.uk/historicandlistedbuildings orwww.environment.scotland.gov.uk.

    http://www.historicscotland.gov.uk/historicandlistedbuildingshttp://www.historicscotland.gov.uk/historicandlistedbuildingshttp://www.historicscotland.gov.uk/historicandlistedbuildingshttp://www.historicscotland.gov.uk/historicandlistedbuildings
  • 7/28/2019 GPD Soctland

    24/83

    24

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse sinGle storey Ground Floor extensions

    Class 1A.

    (1) Any enlargement o a dwellinghouse by way o a single storey ground foor extension, including any

    alteration to the roo required or the purpose o the enlargement.

    (2) Development is not permitted by this class i

    (a) any part o the development would be orward o a wall orming part o the principal elevation or side elevation

    where that elevation ronts a road;

    (b) any part o the development would be within 1 metre o the boundary o the curtilage o the dwellinghouse and

    it would extend beyond the line o the wall orming part o the rear elevation that is nearest that boundary by more

    than

    (i) 3 metres in the case o a terrace house; or(ii) 4 metres in any other case;

    (c) the height o the eaves o the development would exceed 3 metres;

    (d) any part o the development would exceed 4 metres in height;

    (e) as a result o the development the area o ground covered by the resulting dwellinghouse would be more than

    twice the area o ground covered by the original dwellinghouse;

    () as a result o the development the area o ground covered by development within the ront or rear curtilage o

    the dwellinghouse (excluding the original dwellinghouse and any hard surace or deck) would exceed 50% o the

    area o the ront or rear curtilage respectively (excluding the ground area o the original dwellinghouse and any hard

    surace or deck); or(g) it would be within a conservation area.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    25/83

    25

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    Ground foor extension o moretan a one store

    SUMMARy=0.

    4.25

    Permitted development rights allow the

    enlargement o a dwellinghouse by the way o

    a ground oor extension consisting o more

    than one storey. The permitted development

    rights also allow any alteration to the roo

    required or the purpose o the enlargement. In

    summary, the eect o the limitations is that: extensions are generally located to the rear

    the distance between the extension and

    any boundary is a minimum o 10 metres

    the height o the extension is not higher

    than the existing dwellinghouse

    the ootprint o the extension is not larger

    than the originaldwellinghouse or covering

    more than hal the curtilage

    4.26

    Many 1 storey and 2 storey extensions

    are more likely to have a greater impact than

    a single storey extension. It is recognisedthat the majority o 1 storey and 2 storey

    extensions will require an application or

    planning permission.

    4.27

    There are no permitted development rights in

    conservation areasor or ats. Listed building

    consent will normally be required i your

    building is Listed.

    4.28

    A building warrant rom the local authority

    will be required or this type o extension, as

    explained in Section 2.

  • 7/28/2019 GPD Soctland

    26/83

    26

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    TEChNICAl EXPlANATION

    4.29I the extension exceeds any o the ollowing

    limits then an application or planning

    permission is required.

    4.30

    The extension cannot be orward o a wall

    orming part o the principalelevationor side

    elevation i that elevation is rontinga road.

    The identifcation o the principal elevation and

    side elevations are discussed in paragraphs

    3.2 3.6, whilst ronting a roadis discussed

    at 3.7 3.10. This is illustrated in fgure 14.

    Figure 14: The shaded areas o the curtilage indicate where an extension o more than a

    single storey is permitted as long as the other limitations are met.

    https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/
  • 7/28/2019 GPD Soctland

    27/83

    27

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    4.31

    1 storey or 2 storey extensions are more

    likely to have a visual impact, potentially

    causing overshadowing or overlooking. Nopart o the extension can thereore be within

    10 metres o any boundary o the curtilage.

    4.32

    The overall height o the extension cannot be

    higher than the existing roo. This would be

    the ridge o the roo. Roo alterations relating

    to the extension are also permitted. Other roo

    alterations should be carried out using theother relevant classes.

    4.33

    The area covered by all extensions, including

    any existing and the proposed extension,

    cannot be greater than the ootprint o the

    original dwellinghouse. This is to ensure that

    the extension (including previous extensions)

    is in proportion to the original dwellinghouse.

    4.34

    The proposed extension (including previous

    extensions) and existing developments cannot

    exceed hal o the rear (or ront i appropriate)

    curtilage o the original dwellinghouse. This is

    explained urther in paragraphs 3.11 3.13.

    4.35

    There are no Class 1B permitted development

    rights in a conservation areaor or ats.

    A listed building consent is required i theproposed extension aects the character or

    setting o a listed building.

    4.36

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listedbuildings is available rom http://www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

    10.0m

    10.0m10

    .0m

  • 7/28/2019 GPD Soctland

    28/83

    28

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    Class 1B.

    (1) Any enlargement o a dwellinghouse by way o a ground foor extension consisting o more than one

    storey, including any alteration to the roo required or the purpose o the enlargement.

    (2) Development is not permitted by this class i

    (a) any part o the development would be orward o a wall orming part o the principal elevation or side elevation

    where that elevation ronts a road;

    (b) any part o the development would be within 10 metres o the boundary o the curtilage o the dwellinghouse;

    (c) as a result o the development the height o the dwellinghouse would exceed the height o the existing

    dwellinghouse, when measured at the highest part o the roo and excluding any chimney;

    (d) as a result o the development the area o ground covered by the resulting dwellinghouse would be more thantwice the area o ground covered by the original dwellinghouse;

    (e) as a result o the development the area o ground covered by development within the ront or rear curtilage o

    the dwellinghouse (excluding the original dwellinghouse and any hard surace or deck) would exceed 50% o the

    area o the ront or rear curtilage respectively (excluding the ground area o the original dwellinghouse and any hard

    surace or deck); or

    () it would be within a conservation area.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    29/83

    FORWARD | BACK | CONTENTS | CLOSE

    a

    2.0mb

    a x b < 3.0 m2

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    Porc

    4.37

    Permitted development rights al low theerection, construction or alteration o any

    porch outside any external door o a

    dwellinghouse. The limitations are:

    the porch cannot have a ootprint o greater

    than 3 square metres

    the minimum distance between the porch

    and any boundary and a road is more than

    2 metres

    the height o the porch cannot be higher

    than 3 metres

    4.38

    I the porch exceeds any o the above limits

    thenan application or planning permissionis

    required.

    4.39

    There are no permitted development rights

    or porches in a conservation area or or a

    at. A listed building consentis required i the

    proposed extension aects the character or

    setting o a listed building.

    4.40

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listedbuildings is available rom http://www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk

    4.41

    A building warrant rom the local authority

    may be required or porches, as explained in

    Section 2.

    29

    https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/
  • 7/28/2019 GPD Soctland

    30/83

    30

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Ground Floor extension oF more tHan a one storey

    Class 1C.

    (1) The erection, construction or alteration o any porch outside any external door o a dwellinghouse.

    (2) Development is not permitted by this class i

    (a) its ootprint would exceed 3 square metres;

    (b) any part o it would be within 2 metres o a boundary between the curtilage o the dwellinghouse and a road;

    (c) any part o the development would exceed 3 metres in height; or

    (d) it would be within a conservation area.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    31/83

    31

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse enlarGement oF tHe rooF

    Enargement o te roo

    SUMMARy

    4.42

    Permitted development rights al low the

    enlargement o a dwellinghouse by way o

    an addition or alteration to its roo. This class

    typically relates to the addition o a dormer.

    A badly designed dormer can harm the

    appearance o a dwellinghouse. The larger the

    dormer, the more challenging it is to produce

    a good design. In summary, the eect o the

    limitations is that:

    dormers are generally located to the rear

    the distance between the dormer and

    boundary it ronts is a minimum o

    10 metres

    the height o the dormer is not higher than

    the existing dwellinghouse

    the dormer, or dormers, covers less thanhal the roo

    the distance between the dormer and

    the edge o the roo is a minimum o

    0.3 metres

    4.43

    There are no permitted development rights to

    enlarge a roo in a conservation area. Listed

    building consent will normally be required iyour building is Listed.

    4.44

    Building standards may apply and a building

    warrant rom the local authority may be

    required or this type o development as

    explained in Section 2.

  • 7/28/2019 GPD Soctland

    32/83

    32

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse enlarGement oF tHe rooF

    TEChNICAl EXPlANATION

    4.45

    I the development exceeds any o the

    ollowing limits then an application or

    planning permission is required.

    4.46

    Figure 15 overlea illustrates the restrictions

    or a dormer, the highlighted areas indicate

    where the development is not permitted as

    long as the other limitations are met.

    4.47

    There are no permitted development rights

    in a conservation areaor or ats. A listed

    building consent is required i the proposeddevelopment aects the character or setting

    o a listed building.

    4.48

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listed

    buildings is available rom www.historic-

    scotland.gov.uk/historicandlistedbuildings orwww.environment.scotland.gov.uk.

    https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/
  • 7/28/2019 GPD Soctland

    33/83

    33

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse enlarGement oF tHe rooF

    4.49

    The development cannot be part o the

    roo orming the principal elevation or side

    elevation i that elevation is ronting a road.The identifcation o the principal elevation and

    side elevations are discussed in paragraphs

    3.2 3.6, whilst ronting a road is discussed at

    3.7 3.10.

    4.50

    Any enlargement or alteration to a roo is likely

    to have a visual impact and potentially cause

    overlooking. The development must be at least

    10 metres rom the boundary that it ronts.

    4.51

    The dormer must not exceed hal the width o

    the roo plane (the width o the roo plane is

    measured at the eaves line). The development

    must be at least 0.3 metres rom the edge o

    the roo plane, or example the ridge o the

    roo or the edge o a hipped roo.

    4.52

    The overall height o the dwellinghouse

    cannot be increased as a result o the

    development. This is measured against the

    existing ridge o the roo.

    10.0m0.3

    m

    a

    b

    x

    0.3m

    0.3m

    0.3m

    a + b 1/2 x

    Figure 15: Roo enlargements

  • 7/28/2019 GPD Soctland

    34/83

    34

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse enlarGement oF tHe rooF

    Class 1D.

    (1) Any enlargement o a dwellinghouse by way o an addition or alteration to its roo.

    (2) Development is not permitted by this class i

    (a) it would be on a roo plane orming part o the principal elevation or side elevation where that elevation ronts a

    road;

    (b) it would be on a roo plane and would be within 10 metres o the boundary o the curtilage o the dwellinghouse

    which that roo plane ronts;

    (c) as a result o the development the height o the dwellinghouse would exceed the height o the existing

    dwellinghouse, when measured at the highest part o the roo and excluding any chimney;

    (d) its width would exceed hal the total width o the roo plane, measured at the eaves line, o the dwellinghouse;(e) any part o the development would be within 0.3 metres o any edge o the roo plane o the dwellinghouse; or

    () it would be within a conservation area.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    35/83

    35

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse introduction to improvements, additions or alterations to a dwellinGHouse tHat are not

    an enlarGement

    Introduction to improements,additions or aterations to adeingouse tat are not an

    enargement4.53

    There are many types o alterations or

    improvements to a dwellinghouse that

    are not enlargement. The most common

    types o alterations or improvements to a

    dwellinghouses are described in classes 2A

    and 2B.

    Access Ramps

    Class 2A The erection, construction or

    alteration o any access ramp outside any

    external door o a dwellinghouse.

    This class allows small ramps to

    be attached to any external door o

    dwellinghouse so long as certain limitations

    are met. The ramp is not longer than

    5 metres and the overall length o ramp

    and landings is not longer than 9 metres.

    The ramp is not higher than 0.4 metres and

    the combined height o the ramp and anyhandrail does not exceed 1.5 metres.

    Improements or aterations tat are not

    an enargement, incuding repacement

    indos, soar panes, fues and

    sateite dises etcClass 2B Any improvement, addition or

    other alteration to the external appearance o

    a dwellinghouse that is not an enlargement.

    This class is best visualised as a 1 metre

    bubble surrounding the walls and roo o

    a dwellinghouse. A householder can add a

    wide range o dierent types o development

    without having to apply or planningpermission.

    Wind turbines, balconies, raised terraces or

    platorms are not permitted by this class.

    4.54

    These permitted development rights do NOT

    apply toats.

    4.55

    I the proposed development alls into any o

    the above classes and is in a conservation

    area then an application to the planning

    authority is required.

    http://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planninghttp://www.scotland.gov.uk/Topics/Built-Environment/planning/Local-Planning
  • 7/28/2019 GPD Soctland

    36/83

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    37/83

    37

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse access ramps

    Class 2A.(1) The erection, construction or alteration o any access ramp outside an external door o a dwellinghouse.

    (2) Development is not permitted by this class i

    (a) the combined length o all ights orming part o the access ramp would exceed 5 metres;

    (b) the combined length o all ights and landings orming part o the access ramp would exceed 9 metres;

    (c) any part o the ramp would exceed 0.4 metres in height;

    (d) the combined height o the ramp and any wall (excluding any external wall o the dwellinghouse), ence,

    balustrade, handrail or other structure attached to it would exceed 1.5 metres; or

    (e) it would be within a conservation area or within the curtilage o a listed building.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    38/83

    38

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - improvements or alterations tHat are not an enlarGement, includinG replacement

    windows, solar panels, Flues and satellite disHes etc

    Improements or aterations tatare not an enargement, incudingrepacement indos, soar

    panes, fues, and sateite disesetc

    4.61

    Permitted development rightsallow any

    improvement, addition or other alteration to

    the external appearance o a dwellinghouse

    that is not an enlargement. This is best

    visualised as a 1 metre bubble surrounding

    the dwellinghouse. A householder can

    thereore carry out a wide range o dierent

    types o development without having to apply

    or planning permission. This class also covers

    the installation, alteration or replacement o

    solar PV or solar thermal equipment.

    4.62

    I the development exceeds any o the

    ollowing limits then an application or

    planning permission is required.

    4.63

    The development must not enlarge the

    dwellinghouse. This means that the

    development cannot increase the internalvolume o the original building. This includes

    a canopy or roo, with or without wall, which is

    attached to the building but does not include a

    balcony.

    4.64

    The development must not project by more

    than 1 metre rom the wall or roo.

    4.65

    The ollowing types o development are not

    permitted by this class:

    balcony, roo terrace or raised platorm

    wind turbine

    4.66

    The ollowing developments are also not

    permitted as they are permitted by other

    classes: access ramps

    a range o building or engineering

    operations including garden works, oil tanks

    a ue orming part o biomass heating

    system

    ue orming part o combined heat and

    power system

    air source heat pump

    CCTV

    4.67

    Section 6 discusses the installation, alteration

    or replacement o a biomass heating system

    ue or a combined heat and powers system

    ue or air source heat pump.

  • 7/28/2019 GPD Soctland

    39/83

    39

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - improvements or alterations tHat are not an enlarGement, includinG replacement

    windows, solar panels, Flues and satellite disHes etc

    4.68

    To ensure that the general character o an

    area is maintained, there is a condition that

    materials used or any roo covering mustbe similar in appearance to the existing roo.

    Solar PV or solar thermal panels are not

    considered to be a roo covering.

    4.69

    An alteration to the external appearance

    would allow the painting (or repainting) o the

    property. It would also allow the painting or

    attaching o an advertisement to the property.While an application or planning consent

    may not be required by virtue o this class, an

    application or advertisement consent may be

    required under the Town and Country Planning

    (Control o Advertisements) (Scotland)

    Regulations 1984 depending on the nature

    and size o any such advertisement.

    4.70

    There are no Class 2B permitted development

    rights in a conservation area. Listed

    building consent is required i the proposeddevelopment aects the character or setting

    o alisted building.

    4.71

    A building warrant rom the local authority may

    be required, as explained in Section 2.

    4.72

    Planning authorities will be able to confrmwhether a property is located within a

    conservation area. Inormation on listed

    buildings is available rom http://www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

  • 7/28/2019 GPD Soctland

    40/83

    40

    FORWARD | BACK | CONTENTS | CLOSE

    Class 2B.(1)Any improvement, addition or other alteration to the external appearance o a dwellinghouse that is not an

    enlargement.

    (2) Development is not permitted by this class i

    (a) it would protrude more than 1 metre rom the outer surace o an external wall, roo plane, roo ridge or chimney

    o the dwellinghouse;

    (b) it would be a wind turbine;

    (c) it would be a balcony;

    (d) it would be on the roo and would result in a raised platorm or terrace;

    (e) it would be within a conservation area; or() it would be development described in class 2A(1), 3B(1), 6C(1), 6F(1), 6H(1) or 72(1).

    (3) Development is permitted by this class subject to the condition that the materials used or any roo covering must be

    as similar in appearance to the existing roo covering as is reasonably practicable.

    lEGISlATION

    4. makinG cHanGes to a dwellinGHouse - improvements or alterations tHat are not an enlarGement, includinG replacement

    windows, solar panels, Flues and satellite disHes etc

  • 7/28/2019 GPD Soctland

    41/83

    41

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - introduction to otHer development witHin tHe curtilaGe oF a dwellinGHouse

    Introduction to oter deeopmentitin te curtiage o adeingouse

    4.73

    There are many other types o developments

    that can happen within the curtilage o

    dwellinghouse. The ollowing 5 classes cover

    the most common types o developments.

    Installation o microgeneration equipment is

    discussed in Section 6.

    Anciar buidings incuding seds,

    garages, sun-ouses, greenouses

    etc.

    Class 3A The provision within thecurtilage o a dwellinghouse o any

    building required or a purpose incidental

    to the enjoyment o a dwellinghouse or

    the maintenance or improvement o such

    a building.

    This class generally allows the provision o

    any building incidental to the enjoyment o

    the dwellinghouse i it is in the rearcurtilage. In the main this covers sheds,

    garages, greenhouses etc.

    In the case o dwellinghouses in a

    conservation areaor within the curtilage o a

    listed building, the oor area o the ancillary

    building can not exceed 4 square metres.

    An buiding, engineering, instaation

    or oter operation

    Class 3B The carrying out o any building,

    engineering, installation or other operationwithin the curtilage o a dwellinghouse,

    required or a purpose incidental to the

    enjoyment o that dwellinghouse.

    This class generally allows or the carrying

    out o an operation within the rear curtilage

    o a dwellinghouse not covered by other

    classes. Typical development permitted by

    this class include ree-standing solar panels,ag poles, swimming pools, oil tanks etc.

    This permitted development rights does not

    apply in conservation areas or within the

    curtilage o a listed building.

  • 7/28/2019 GPD Soctland

    42/83

    42

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - introduction to otHer development witHin tHe curtilaGe oF a dwellinGHouse

    Decing or oter raised patorm

    Class 3D The erection, construction,

    maintenance, improvement or alteration o

    any deck or other raised platorm withinthe curtilage o a dwellinghouse or any

    purpose incidental to the enjoyment o the

    dwellinghouse.

    This class generally permits the

    construction o a deck or other raised

    platorm in the rear garden so long as the

    oor level does not exceed 0.5 metres and

    the combined height o the deck and anyattached balustrade or screening does not

    exceed 2.5 metres.

    In the case o land in aconservation areaor

    within the curtilage o a listed building, the

    ootprint o the deck cannot exceed

    4 square metres.

    hard surace

    Class 3C The provision within the

    curtilage o a dwellinghouse o a hard

    surace or any purpose incidental to theenjoyment o the dwellinghouse or the

    replacement in whole or in part o such a

    surace.

    This class generally permits the

    construction or replacement o a hard

    surace. I the hard surace is between

    the dwellinghouse and a road then the

    materials used should be permeable or,alternatively, rain water run o should be to

    a permeable surace within the curtilage.

    This permitted development rights or hard

    suraces does not apply inconservation

    areasor within the curtilage o alisted

    building.

    Gates, ences, as or oter means o

    encosure

    Class 3E The erection, construction,

    maintenance, improvement or alterationo any gate, ence, wall or other means

    o enclosure any part o which would be

    within or would bound the curtilage o a

    dwellinghouse.

    The overall height o the gate, ence, wall or

    other means o enclosure must not exceed

    2 metres. However, i it ronts a road or

    comes orward o the principal elevation orside elevation nearest a road then it cannot

    exceed 1 metre. Where an existing gate,

    ence, wall or other means o enclosure is

    replaced or altered the height limit is either

    1 metre or 2 metre or, i greater than these,

    the height o the original structure.

    These permitted development rights do not

    apply in aconservation areaor within the

    curtilage o a listed building.

  • 7/28/2019 GPD Soctland

    43/83

    43

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse ancillary BuildinGs includinG sHeds, GaraGes, GreenHouses etc

    Anciar buidings incudingseds, garages, greenouses etc

    SUMMARy

    4.74

    Permitted development rights al low or

    the provision o any building required or a

    purpose incidental to the enjoyment o the

    dwellinghouse. Typical developments include

    sheds, garages, sun-houses and greenhouses.

    In summary, the eect o the limitations is that:

    ancillary buildings are generallylocated to the rear

    at least hal the curtilage remains

    undeveloped

    the height o the building is not higher than

    4 metres and the sections within 1 metre

    o the boundary would be higher than

    2.5 metres

    the height o the eaves is not higher than

    3 metres

    4.75

    In the case o dwellinghouses in a

    conservation area or within the curtilage o

    a listed building development is permitteddevelopment as long as the ootprint o the

    ancillary building does not exceed 4 square

    metres. Listed building consent is required

    i the proposed development aects the

    character or setting o a listed building.

    4.76

    A building warrant rom the local authority may

    be required or these types o developments,

    as explained in Section 2.

  • 7/28/2019 GPD Soctland

    44/83

    44

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse ancillary BuildinGs includinG sHeds, GaraGes, GreenHouses etc

    TEChNICAl EXPlANATION

    4.77

    I the building exceeds any o the ollowinglimits then an application or planning

    permission is required.

    4.78

    The building cannot be used as a separate

    dwelling.

    4.79

    The building cannot be orward o a wallorming part o the principal elevation or side

    elevation i that elevation is ronting a road.

    The identifcation o the principal elevation and

    side elevations are discussed in paragraphs

    3.2 3.6, whilst ronting a road is discussed at

    3.7 3.10.

    4.80

    This is illustrated below, the shaded areaso the curtilage indicate where an ancillary

    building is permitted as long as the other

    limitations are met.

    4.81

    The overall height o a building can have a

    signifcant impact on neighbours. The eaves

    o the building cannot be higher than3 metres. The height o the building cannot

    exceed 4 metres.

    4.82

    The parts o the building within 1 metre o a

    boundary must not be higher than 2.5 metres.

    This is illustrated on page 43.

    4.83

    When measuring the height o thedevelopment on sloping or uneven ground, the

    height should be measured rom the lowest

    point immediately adjacent to the extension.

    4.84

    The proposed development and existing

    developments (including extensions, sheds,

    garages) cannot exceed hal o the o the rear(or ront i appropriate) curtilage o the original

    dwellinghouse, this is explained in paragraphs

    3.11 3.12.

    4.85

    In the case o dwellinghouses in a

    conservation areaor within the curtilage o a

    listed building, the oor area o the ancillary

    building cannot exceed 4 square metres.

    A listed building consent is required i the

    proposed development aects the character

    or setting o a listed building.

    4.86

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listed

    buildings is available rom www.historic-

    scotland.gov.uk/historicandlistedbuildings orwww.environment.scotland.gov.uk.

  • 7/28/2019 GPD Soctland

    45/83

    45

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse ancillary BuildinGs includinG sHeds, GaraGes, GreenHouses etc

    Class 3A.(1) The provision within the curtilage o a dwellinghouse o a building or any purpose incidental to the

    enjoyment o that dwellinghouse or the alteration, maintenance or improvement o such a building.

    (2) Development is not permitted by this class i

    (a) it consists o a dwelling;

    (b) any part o the development would be orward o a wall orming part o the principal elevation or side elevation

    where that elevation ronts a road;

    (c) the height o the eaves would exceed 3 metres;

    (d) any part o the development would exceed 4 metres in height;

    (e) any part o the development within 1 metre o the boundary o the curtilage o the dwellinghouse would exceed2.5 metres in height;

    () as a result o the development the area o ground covered by development within the ront or rear curtilage o

    the dwellinghouse (excluding the original dwellinghouse and any hard surace or deck) would exceed 50% o the

    area o the ront or rear curtilage respectively (excluding the ground area o the original dwellinghouse and any hard

    surace or deck); or

    (g) in the case o land in a conservation area or within the curtilage o a listed building, the resulting building would

    have a ootprint exceeding 4 square metres.

    lEGISlATION

  • 7/28/2019 GPD Soctland

    46/83

    46

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - any BuildinG, enGineerinG, installation or otHer operation

    An buiding, engineering,instaation or oter operation

    SUMMARy

    4.87

    Permitted development rights allow or the

    carrying out o works within the rear curtilage

    o a dwellinghouse not covered by other

    classes. It is intended to apply to garden

    works, ree-standing solar panels, ag poles,

    swimming pools and oil tanks. In summary, the

    eect o limitations is that: the development is generally located in the

    rear

    the height o the resulting structure is not

    higher than 3 metres

    at least hal the curtilage remains

    undeveloped

    4.88

    This permitted development rights do not apply

    in conservation areas or within the curtilage o

    a listed building.

    4.89

    A building warrant rom the local authority may

    be required or these types o developments,

    as explained in Section 2.

  • 7/28/2019 GPD Soctland

    47/83

    47

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - any BuildinG, enGineerinG, installation or otHer operation

    TEChNICAl

    4.90

    I the development exceeds any o theollowing limits then an application or planning

    permissionis required.

    4.91

    Building operation is included in the

    description, as in terms o the defnition o

    development and includes a wider range o

    development than just the provision o an

    actual building.

    4.92

    The development cannot be orward o a wall

    orming part o the principal elevation or side

    elevation i that elevation is ronting a road.

    The identifcation o theprincipal elevationand

    side elevations are discussed in paragraphs

    3.2 3.6, whilstronting a road is discussed at

    3.7 3.10.

    4.93

    This is illustrated below, the shaded areas o

    the curtilage indicate where works is permitted

    as long as the other limitations are met.

    4.94

    The overall height o the development can

    have a signifcant impact on neighbours.

    The development cannot be higher than3 metres. When measuring the height o the

    development on sloping or uneven ground, the

    height should be measured rom the lowest

    point immediately adjacent to the development.

  • 7/28/2019 GPD Soctland

    48/83

    48

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - any BuildinG, enGineerinG, installation or otHer operation

    4.95

    The proposed development and existing

    developments (including extensions, sheds,

    garages etc.) cannot exceed hal o the rearcurtilage (or ront i appropriate) curtilage o

    the original dwellinghouse, this is explained in

    paragraphs 3.12 3.13.

    4.96

    The ollowing types o development are not

    permitted by this class, as these types o

    developments are permitted by other classes:

    ancillary buildings hard surace

    decking

    gate, ence, wall or other means o

    enclosure

    ground source heat pump

    water source heatpump

    ree-standing wind turbine air source heat pump

    means o access

    4.97

    There are no Class 3B permitted development

    rights in a conservation areaor within the

    curtilage o alisted building. An application tothe planning authority is required.

    4.98

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation onlisted

    buildings is available rom www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

    | | |

  • 7/28/2019 GPD Soctland

    49/83

    49

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse - any BuildinG, enGineerinG, installation or otHer operation

    Class 3B.(1) The carrying out o any building, engineering, installation or other operation within the curtilage o a

    dwellinghouse or any purpose incidental to the enjoyment o that dwellinghouse.

    (2) Development is not permitted by this class i

    (a) any part o the development would be orward o a wall orming part o the principal elevation or side elevation

    where that elevation ronts a road;

    (b) any resulting structure would exceed 3 metres in height;

    (c) as a result o the development the area o ground covered by development within the ront or rear curtilage o

    the dwellinghouse (excluding the original dwellinghouse and any hard surace or deck) would exceed 50% o the

    area o the ront or rear curtilage respectively (excluding the ground area o the original dwellinghouse and any hardsurace or deck);

    (d) it would be within a conservation area or within the curtilage o a listed building; or

    (e) it would be development described in class 3A(1), 3C(1), 3D(1), 3E(1), 6D, 6E, 6G(1), 6H(1) or 8.

    lEGISlATION

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    50/83

    50

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Hard surFace

    hard surace

    4.99

    Permitted development rights al low the

    construction or replacement o a hard surace

    within the curtilage o a dwellinghouse.

    4.100

    I the hard surace exceeds any o the

    ollowing limits then an application or

    planning permission is required.

    4.101

    I the hard surace is located between the

    dwellinghouse and a road, then it must be

    constructed o a porous material or that

    provision is made or surace water run o

    to be directed to a porous area within the

    curtilage o the dwellinghouse.

    4.102

    This provision is introduced ollowing a review

    o extreme ooding events and concerns

    expressed by regulatory authorities and watercompanies that the cumulative impact o

    small increases in hard suracing is leading

    to increased run o into road drains that

    ultimately ow into watercourses or sewage

    treatment works. The intention o the condition

    is to encourage householders to adopt the

    principles o source control.

    4.103

    The Department o Communities and Local

    Government has produced separate guidance

    on permeable paving. This can be ound

    at:www.communities.gov.uk/documents/

    planningandbuilding/pd/pavingrontgardens.pd.

    4.104

    Planning permission is required or a hard

    surace in conservation areas and in the

    curtilage o listed buildings. A buildingwarrant rom the local authority may

    be required, as explained in Section 2.

    4.105

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation onlisted

    buildingsis available rom: www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

    FORWARD | BACK | CONTENTS | CLOSE

    http://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdfhttp://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdfhttp://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdfhttp://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdfhttp://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdfhttp://www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdf
  • 7/28/2019 GPD Soctland

    51/83

    51

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Hard surFace

    Class 3C.(1) The provision within the curtilage o a dwellinghouse o a hard surace or any purpose incidental to the

    enjoyment o that dwellinghouse or the replacement in whole or in part o such a surace.

    (2) Development is not permitted by this class i it would be within a conservation area or within the curtilage o a

    listed building.

    (3) Development is permitted by this class subject to the condition that where the hard surace would be located

    between the dwellinghouse and a road bounding the curtilage o the dwellinghouse

    (a) the hard surace must be made o porous materials; or

    (b) provision must be made to direct run o water rom the hard surace to a permeable or porous area or surace

    within the curtilage o the dwellinghouse.

    lEGISlATION

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    52/83

    52

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse deckinG or otHer raised platForm

    Decing or oter raised patorm

    SUMMARy

    4.106

    Permitted development rights al low theerection, construction, maintenance,improvement or alteration o any deck orother raised platorm within the curtilage o adwellinghouse. In summary, the eect o thelimitations is that:

    decks are generally located to the rear

    the height o the oor level does not

    exceed 0.5 metre the total height o the deck, including any

    attached structure does not exceed2.5 metres

    4.107

    I the deck, or raised platorm, is in aconservation area or within the curtilage olisted building the maximum size o the deck,or raised platorm, is 4 square metres. There

    are no permitted development rights or ats.

    4.108

    A building warrant rom the local authoritymay be required or the deck or other raised

    platorm, as explained in Section 2.

  • 7/28/2019 GPD Soctland

    53/83

    53

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse deckinG or otHer raised platForm

    TEChNICAl EXPlANATION

    4.109

    I the deck, or raised platorm, exceeds any

    o the ollowing limits then an application or

    planning permission is required.

    4.110

    Decks cannot be orward o a wall orming

    part o the principal elevation or side elevation

    i that elevation is ronting a road. The

    identifcation o the principal elevation and

    side elevations are discussed in paragraphs3.2 3.6, whilst ronting a road is discussed at

    3.7 3.10.

    4.111

    This is illustrated below, the shaded areas o

    the curtilage indicate where an extension is

    permitted as long as the other limitations are

    met.

    4.112

    The maximum height o the platorm o the

    decking is 0.5 metre. The total height i, or

    example screens are attached, is 2.5 metres.

    4.113

    When measuring the height o the deck

    on sloping or uneven ground, the height

    should be measured rom the lowest point

    immediately adjacent to the decking.

    4.114

    The size o decking in conservation areas

    and within the curtilage o listed buildings is

    restricted to 4 square metres to be permitteddevelopment.

    4.115

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation onlisted

    buildingsis available rom www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

    FORWARD | BACK | CONTENTS | CLOSE

    https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/https://eplanning.scotland.gov.uk/WAM/
  • 7/28/2019 GPD Soctland

    54/83

    54

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse deckinG or otHer raised platForm

    Class 3D.(1) The erection, construction, maintenance, improvement or alteration o any deck or other raised platorm

    within the curtilage o a dwellinghouse or any purpose incidental to the enjoyment o that dwellinghouse.

    (2) Development is not permitted by this class i

    (a) any part o the development would be orward o a wall orming part o the principal elevation or side elevation

    where that elevation ronts a road;

    (b) the oor level o any part o the deck or platorm would exceed 0.5 metres in height;

    (c) the combined height o the deck and any wall, ence, balustrade, handrail or other structure attached to it, would

    exceed 2.5 metres; or

    (d) in the case o land within a conservation area or within the curtilage o a listed building the deck or platormwould have a ootprint exceeding 4 square metres.

    lEGISlATION

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    55/83

    55

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Gates, Fences, walls or otHer means oF enclosure

    Gates, ences, as or otermeans o encosure

    4.116

    Permitted development rights al low the

    erection, construction, maintenance,

    improvement or alteration o any gate,

    ence, wall or other means o enclosure.

    4.117

    I the gate, ence, wall or other means o

    enclose exceeds the ollowing limits then

    an application or planning permission

    is required.

    4.118

    The maximum height o any gate, ence, wall

    or other means o enclosure is 2 metres.

    Whilst its maximum height 1 metre i it ronts

    a road (explained in paragraphs 3.9 - 3.10)

    or comes orward o theprincipal elevationor

    side elevation nearest a road. Identiying the

    principal elevation is explained in paragraphs3.2 3.6.

    4.119

    When measuring the height o the

    development on sloping or uneven ground, the

    height should be measured rom the lowestpoint immediately adjacent to the gate, ence,

    wall or other means o enclosure.

    4.120

    The replacement or alteration o an existing

    gate, ence, wall or other means o enclosure

    to its original height is permitted. For example,

    an existing 1.2 metre ence orward o the

    principal elevation can be replaced with

    a ence up to 1.2 metres in height. I the

    replacement ence is higher than 1.2 metres

    then an application or planning permission

    would be required. Alternatively, i replacing a

    0.8 metre high ence orward o the principal

    elevationit can be replaced by with a ence up

    to 1 metre in height.

    4.121

    Planning permission is needed or gates,

    ences, wall or other mean o enclosure in

    conservation areas and in the curtilage o

    listed buildings.

    4.122

    Planning authorities will be able to confrm

    whether a property is located within a

    conservation area. Inormation on listed

    buildings is available rom www.historic-

    scotland.gov.uk/historicandlistedbuildings or

    www.environment.scotland.gov.uk.

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    56/83

    56

    FORWARD | BACK | CONTENTS | CLOSE

    4. makinG cHanGes to a dwellinGHouse Gates, Fences, walls or otHer means oF enclosure

    Class 3E.(1) The erection, construction, maintenance, improvement or alteration o any gate, ence, wall or other

    means o enclosure any part o which would be within or would bound the curtilage o a dwellinghouse.

    (2) Development is not permitted by this class i

    (a) any part o the resulting gate, ence, wall or other means o enclosure would exceed 2 metres in height;

    (b) any part o the resulting gate, ence, wall or other means o enclosure would exceed one metre in height where

    it

    (i) ronts a road; or

    (ii) extends beyond the line o the wall o the principal elevation or side elevation that is nearest a road;

    (c) it replaces or alters an existing gate, ence, wall or other means o enclosure and exceeds whichever is thegreater o the original height or the heights described in sub-paragraphs (a) and (b);

    (d) it would be within a conservation area; or

    (e) it would be within, or bound, the curtilage o a listed building.

    lEGISlATION

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    57/83

    57

    FORWARD | BACK | CONTENTS | CLOSE

    5. makinG cHanGes to a Flat

    5.1

    Due to the vast variety o ats, it is not

    possible to provide extensive permitted

    development rights or ats.

    5.2

    A at is defned as a separate and sel

    contained set o premises whether or not on

    the same oor and orming part o a building

    rom some other part o which it is divided

    horizontally.

    5.3

    The specifc permitted development rights orats are detailed below. Other relevant classes

    include:-

    Class 7: construction o gate, ences, walls

    and other means o enclosure

    Class 72: Closed Circuit Television Cameras

    (CCTV).

    Improements or aterations tatare not an enargement, incudingrepacement indos, soar

    panes, fues, sateite dises

    SUMMARy

    5.4

    Permitted development rights allow any

    improvement or other alteration to the external

    appearance o a dwelling situated within a

    building containing one or more ats that is

    not an enlargement. This is best visualised as

    a 1 metre bubble surrounding a at. A widerange o dierent types o developments are

    permitted without having to apply or planning

    permission, including the installation, alteration

    or replacement o solar PV or solar thermal

    equipment. In summary, the eect o the

    limitations is that:

    the development does not enlarge the at

    the distance any development can projectrom the walls and roo o the at is not

    more than 1 metre

    the development is not a balcony, roo

    terrace or raised platorm, wind turbine,

    a ue orming part o biomass heating

    system, ue orming part o combined heatand power system, air source heat pump,

    CCTV or an enlargement

    5.5

    There are no permitted development rights in

    a conservation area or within the curtilage o

    a listed building. A listed building consent is

    required i the proposed development aects

    the character or setting o a listed building.

    5.6

    A building warrant rom the local authority may

    be required, as explained in Section 2.

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    58/83

    58

    O | C | CO S | C OS

    5. makinG cHanGes to a Flat improvements or alterations tHat are not an enlarGment, includinG replacement windows, solar

    panels, Flues and satellite disHes etc.

    TEChNICAl EXPlANATION

    5.7

    I the development exceeds any o theollowing limits then an application orplanning permission is required.

    5.8

    The development must not enlarge the at.This means that the development cannotincrease the internal volume o the originalbuilding. Enlargement includes a canopy orroo, with or without wall, which is attached tothe building but does not include a balcony.

    5.9

    The development must not project by morethan 1 metre rom the wall or roo.

    5.10

    The size o windows and doors cannot bealtered. An application or planning permission

    is required i, or example, a larger window iscreated rom 2 smaller windows or a windowis converted into a door which is larger than

    the window.

    5.11

    The development cannot be a balcony or, iit is on the roo, a raised platorm or terrace.The ollowing types o development are notpermitted by this class because they arepermitted by other classes:

    wind turbine

    biomass heating system ue

    combined heat and powers system ue

    air source heat pump

    CCTV

    5.12

    There are no Class 4A permitted developmentrights or conservation areas or withinthe curtilage o a listed building. Planningauthorities will be able to confrm whethera property is located within a conservationarea. Inormation on listed buildings isavailable rom: www.historic-scotland.gov.uk/historicandlistedbuildings

    or www.environment.scotland.gov.uk.

    5.13

    Section 6discusses the installation, alterationor replacement o a biomass heating system

    ue or a combined heat and powers systemue or air source heat pump.

    5.14

    An alteration to the external appearance o aat would allow the painting (or repainting) othe property. It would also allow the painting orattaching o an advertisement to the property.While an application or planning permissionmay not be required by virtue o this class, an

    application or advertisement consent may berequired under the Town and Country Planning(Control o Advertisements) (Scotland)Regulations 1984 depending on the nature

    and size o any such advertisement.

    FORWARD | BACK | CONTENTS | CLOSE

    http://www.historic-scotland.gov.uk/historicandlistedbuildingshttp://www.historic-scotland.gov.uk/historicandlistedbuildingshttp://www.historic-scotland.gov.uk/historicandlistedbuildingshttp://www.historic-scotland.gov.uk/historicandlistedbuildings
  • 7/28/2019 GPD Soctland

    59/83

    59

    | | |

    Class 4A.(1) Any improvement or other alteration to the external appearance o a dwelling situated within a building

    containing one or more fats.

    (2) Development is not permitted by this class i

    (a) it would be an enlargement;

    (b) it would protrude more than 1 metre rom the outer surace o an external wall, roo plane, roo ridge or chimney;

    (c) the dimensions o an existing window or door opening would be altered;

    (d) it would be a balcony;

    (e) it would be on the roo and would result in a raised platorm or terrace;

    () it would be a wind turbine;(g) it would be within a conservation area or within the curtilage o a listed building; or

    (h) it would be development described in class 6C(1), 6F(1) or 6H(1) or 72(1).

    lEGISlATION

    5. makinG cHanGes to a Flat improvements or alterations tHat are not an enlarGment, includinG replacement windows, solar

    panels, Flues and satellite disHes etc.

    FORWARD | BACK | CONTENTS | CLOSE

  • 7/28/2019 GPD Soctland

    60/83

    60

    | | |

    Gates, ences, as or otermeans o encosure

    5.15

    Permitted development rights al low theerection, construction, maintenance,improvement or alteration o any gate, ence,wall or other means o enclosure.

    5.16

    I the gate, ence, wall or other means oenclosure exceeds any o the ollowing limitsthen an application or planning permission isrequired.

    5.17

    The maximum height o any new gate, ence,wall or other means o enclosure is 2 metres,but where it is within 20 metres o a road themaximum height is 1 metre.

    5.18

    When measuring the height o thedevelopment on sloping or uneven ground, theheight should be measured rom the highest

    point immediately adjacent to the gate, ence,wall or other means o enclosure.

    5.19

    The replacement or alteration o an existinggate, ence, wall or other means o enclosureto its original height is permitted. For example,an existing 1.2 metre ence within 20 metreso a road can be replaced with a ence up to1.2 metres in height. I the replacement ence

    is higher than 1.2 metres then an applicationor planning permission would be required.Alternatively, i replacing a 0.8 metre highence within 20 metres o a road it can bereplaced by with a ence up to 1 metre inheight.

    5.20

    There are no Class 7 permitteddevelopment rights or conservation areasor within the curtilage o alisted building.

    Planning authorities will be able to confrmwhether a property is located within aconservation area. Inormation on listedbuildings is available romwww.historic scotland.gov.uk/historicandlistedbuildings or www.environment.

    scotland.gov.uk

    5. makinG cHanGes to a Flat Gates, Fences, walls or otHer means oF enclosure

    -

    FORWARD | BACK | CONTENTS | CLOSE

    http://www.historic-scotland.gov.uk/historicandlistedbuildingshttp://www.historicscotland.gov.uk/historicandlistedbuildingshttp://www.environment.scotland.gov.uk/http://www.environment.scotland.gov.uk/http://www.historic-scotland.gov.uk/historicandlistedbuildingshttp://www.environment.scotland.gov.uk/http://www.environment.scotland.gov.uk/http://www.historicscotland.gov.uk/historicandlistedbuildingshttp://www.historic-scotland.gov.uk/historicandlistedbuildings
  • 7/28/2019 GPD Soctland

    61/83

    61

    Class 7.(1) The