32
Technical Specification Flygt 3301, 50Hz info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Lenntech

Flygt 3301, 50Hz - Lenntech

  • Upload
    others

  • View
    46

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Flygt 3301, 50Hz - Lenntech

Technical Specification

Flygt 3301, 50Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech

Page 2: Flygt 3301, 50Hz - Lenntech
Page 3: Flygt 3301, 50Hz - Lenntech

Table of Contents

N-pump, Standard Motor.............................................................................................................. 2Product description.....................................................................................................................2Motor rating and performance curves 3301.090/.095/.180/.185.........................................5Motor rating and performance curves 3301.660/.670...........................................................7

N-pump, Premium Efficiency Motor (IE3)................................................................................. 11Product description.................................................................................................................. 11Motor rating and performance curves 3301.800/.810/.820/.830.......................................14Motor rating and performance curves 3301.860/.870.........................................................16

Dimensions and Weight, Standard Motor................................................................................ 19Drawings.................................................................................................................................... 19

Dimensions and Weight, Premium Efficiency Motor (IE3)......................................................25Drawings.................................................................................................................................... 25

Table of Contents

Flygt 3301, 50Hz Technical Specification 1

Page 4: Flygt 3301, 50Hz - Lenntech

N-pump, Standard MotorProduct description

Usage

A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids or long-fibered material. The pump is designed for sustained highefficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller isavailable as an option.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installationtypes

Cast iron 3301.180 3301.090 LT — Low headMT — Medium headHT — High head

P, S, T, Z

Hard-Iron™ 3301.185 3301.095 LT — Low headMT — Medium headHT — High head

P, S, T, Z

Stainless steel 3301.660 3301.670 LT — Low headMT — Medium headHT — High head

P, S

The pump can be used in the following installations:

P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.

S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.

T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.

Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

N-pump, Standard Motor

2 Flygt 3301, 50Hz Technical Specification

Page 5: Flygt 3301, 50Hz - Lenntech

Feature Description

Liquid temperature, warm water version Maximum 70°C (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line• Star-delta• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance between phases Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screened controlcores. Conductor insulation rating of 90°C, which allowsfor increased current. Superior mechanical strength andhigh abrasion and tear resistant. Chemical resistantwithin pH 3-10 and ozone, oil, and flame resistant. Usedup to 70°C water temperature.

Monitoring equipment

• Thermal contacts opening temperature 140° C (284° F)• Leakage sensor in the inspection chamber (FLS 10)

N-pump, Standard Motor

Flygt 3301, 50Hz Technical Specification 3

Page 6: Flygt 3301, 50Hz - Lenntech

Materials

Table 1: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474

Insert ring, alternative 1 Cast iron, gray 35B GJL-250

Insert ring, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Cooling jacket, inner Aluminum AA 1050A AW-1050A

Cooling jacket, outer,alternative 1

Steel GR65 S235JRG2

Cooling jacket, outer,alternative 2

Stainless steel AISI 316L 1.4404,1.4432, …

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70°IRH

- -

O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH

- -

Glycol Heat transfer fluid basedon monopropyleneglycol.

- -

Table 2: Mechanical seals

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/ Corrosionresistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/ Corrosionresistant cemented carbide

Silicon carbide/ Silicon carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Warm liquid version (non-explosion proof versions)• Sensors: Thermistor, FLS, PT 100, VIS 10• Pump memory• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories.

N-pump, Standard Motor

4 Flygt 3301, 50Hz Technical Specification

Page 7: Flygt 3301, 50Hz - Lenntech

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.

Motor rating and performance curves 3301.090/.095/.180/.185These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

LT

WS004062A

0 100 200 300 400 500 6000

2

4

6

8

10

12

14

16

1520253035

810

810

812

812

814

814

816

816

818

818

Q [l/s]

H [m]

P [kW]

LT

0 100 200 300 400 500 6000

5

10

15

20

25

3035404550

620

620

622

622

624

624

626

626

Q [l/s]

H [m]

P [kW]

LT

WS004063A

Table 3: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

37 50 810 735 80 425 0.74 P,T,Z

37 50 812 735 80 425 0.74 P,T,Z

37 50 814 735 80 425 0.74 P,T,Z

37 50 816 735 80 425 0.74 P,T,Z

37 50 818 735 80 425 0.74 P,T,Z

45 60 622 985 93 545 0.78 P,S,T,Z

45 60 624 985 93 545 0.78 P,S,T,Z

45 60 626 985 93 545 0.78 P,S,T,Z

55 74 620 985 113 660 0.78 P,S,T,Z

55 74 622 985 113 660 0.78 P,S,T,Z

55 74 624 985 113 660 0.78 P,S,T,Z

N-pump, Standard Motor

Flygt 3301, 50Hz Technical Specification 5

Page 8: Flygt 3301, 50Hz - Lenntech

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

55 74 626 985 113 660 0.78 P,S,T,Z

MT

WS004064A

0 50 100 150 200 250 300 3500

5

10

15

20

25

30

35

30

40

50

630

630

632

632

634

634

636

636

Q [l/s]

H [m]

P [kW]

MT

Table 4: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

45 60 632 985 93 545 0.78 P,S,T,Z

45 60 634 985 93 545 0.78 P,S,T,Z

45 60 636 985 93 545 0.78 P,S,T,Z

55 74 630 985 113 660 0.78 P,S,T,Z

55 74 632 985 113 660 0.78 P,S,T,Z

55 74 634 985 113 660 0.78 P,S,T,Z

55 74 636 985 113 660 0.78 P,S,T,Z

N-pump, Standard Motor

6 Flygt 3301, 50Hz Technical Specification

Page 9: Flygt 3301, 50Hz - Lenntech

HT

WS004065A

0 20 40 60 80 100 120 140 1600

10

20

30

40

50

60

70

0

20

40

60

80

458

458

450

450

452

452

454

454

456

456

Q [l/s]

H [m]

P [kW]

HT

Table 5: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

55 74 452 1475 103 490 0.84 P,S,T,Z

55 74 454 1475 103 490 0.84 P,S,T,Z

55 74 456 1475 103 490 0.84 P,S,T,Z

55 74 458 1475 103 490 0.84 P,S,T,Z

70 94 450 1475 132 565 0.83 P,S,T,Z

70 94 452 1475 132 565 0.83 P,S,T,Z

70 94 454 1475 132 565 0.83 P,S,T,Z

70 94 456 1475 132 565 0.83 P,S,T,Z

70 94 458 1475 132 565 0.83 P,S,T,Z

Motor rating and performance curves 3301.660/.670These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

N-pump, Standard Motor

Flygt 3301, 50Hz Technical Specification 7

Page 10: Flygt 3301, 50Hz - Lenntech

LT

Q [l/s]

H [m]

2P [kW]

0 100 200 300 400 500 6000

2

4

6

8

10

12

14

16

20

25

30

35

40

LT

810

810

812

812814

814

816

816818

818

WS007740A

Table 6: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

37 50 810 735 80 425 0.74 P,S,T,Z

37 50 812 735 80 425 0.74 P,S,T,Z

37 50 814 735 80 425 0.74 P,S,T,Z

37 50 816 735 80 425 0.74 P,S,T,Z

37 50 818 735 80 425 0.74 P,S,T,Z

N-pump, Standard Motor

8 Flygt 3301, 50Hz Technical Specification

Page 11: Flygt 3301, 50Hz - Lenntech

MT

Q [l/s]

H [m]

2P [kW]

0 50 100 150 200 250 300 3500

5

10

15

20

25

30

35

20

30

40

50

60

MT

630

630

632

632

632

632

632

632

632

632

632

632

632

632

634

634

634

634634634634634

636

636636636636636636

WS007741A

Table 7: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

45 60 632 985 93 545 0.78 P,S,T,Z

45 60 634 985 93 545 0.78 P,S,T,Z

45 60 636 985 93 545 0.78 P,S,T,Z

55 74 630 985 113 660 0.78 P,S,T,Z

55 74 632 985 113 660 0.78 P,S,T,Z

55 74 634 985 113 660 0.78 P,S,T,Z

55 74 636 985 113 660 0.78 P,S,T,Z

N-pump, Standard Motor

Flygt 3301, 50Hz Technical Specification 9

Page 12: Flygt 3301, 50Hz - Lenntech

HT

Q [l/s]

H [m]

2P [kW]

0 20 40 60 80 100 120 1400

10

20

30

40

50

60

20

30

40

50

HT

460

460

462

462

464

464

466

466

WS007739A

Table 8: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

55 74 460 1475 98 520 0.88 P,S,T,Z

55 74 462 1475 98 520 0.88 P,S,T,Z

55 74 464 1475 98 520 0.88 P,S,T,Z

55 74 466 1475 98 520 0.88 P,S,T,Z

70 94 460 1475 132 565 0.83 P,S,T,Z

70 94 462 1475 132 565 0.83 P,S,T,Z

70 94 464 1475 132 565 0.83 P,S,T,Z

70 94 466 1475 132 565 0.83 P,S,T,Z

N-pump, Standard Motor

10 Flygt 3301, 50Hz Technical Specification

Page 13: Flygt 3301, 50Hz - Lenntech

N-pump, Premium Efficiency Motor(IE3)Product description

Usage

A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids or long-fibered material. The pump is designed for sustained highefficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller isavailable as an option.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installationtypes

Cast iron 3301.800 3301.810 LT — Low headMT — Medium headHT — High head

P, S, T, Z

Hard-Iron™ 3301.820 3301.830 LT — Low headMT — Medium headHT — High head

P, S, T, Z

Stainless steel 3301.860 3301.870 MT — Medium headHT — High head

P, S

The pump can be used in the following installations:

P Semi permanent, wet well arrangement with pump installed on two guide bars withautomatic connection to discharge.

S Portable semi permanent, wet well arrangement with hose coupling or flange forconnection to discharge pipeline.

T Vertical permanent, dry well arrangement with flange connection to suction anddischarge piping.

Z Horizontal permanent, dry well arrangement with flange connection to suction anddischarge piping.

N-pump, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 11

Page 14: Flygt 3301, 50Hz - Lenntech

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 3-phase

Starting method • Direct on-line• Star-delta• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance between phases Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screened controlcores. Conductor insulation rating of 90°C, which allowsfor increased current. Superior mechanical strength andhigh abrasion and tear resistant. Chemical resistantwithin pH 3-10 and ozone, oil, and flame resistant. Usedup to 70°C water temperature.

Monitoring equipment

• Thermal contacts opening temperature 140° C (284° F)• Leakage sensor in the inspection chamber (FLS 10)

N-pump, Premium Efficiency Motor (IE3)

12 Flygt 3301, 50Hz Technical Specification

Page 15: Flygt 3301, 50Hz - Lenntech

Materials

Table 9: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474

Insert ring, alternative 1 Cast iron, gray 35B GJL-250

Insert ring, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Cooling jacket, inner Aluminum AA 1050A AW-1050A

Cooling jacket, outer,alternative 2

Stainless steel AISI 316L 1.4404,1.4432, …

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70°IRH

- -

O-rings, alternative 2 Fluorinated rubber (FPM)70° IRH

- -

Glycol Heat transfer fluid based onmonopropylene glycol.

- -

Table 10: Mechanical seals

Alternative Inner seal Outer seal

1 Corrosion resistant cemented carbide/ Corrosionresistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/ Corrosionresistant cemented carbide

Silicon carbide/ Silicon carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Sensors: Thermistor, FLS, PT 100, VIS 10• Pump memory• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories.

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables.

N-pump, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 13

Page 16: Flygt 3301, 50Hz - Lenntech

Motor rating and performance curves 3301.800/.810/.820/.830These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

LT

0 100 200 300 400 500 6000

5

10

15

20

25

3035404550

620

620

622

622

624

624

626

626

Q [l/s]

H [m]

P [kW]

LT

WS004063A

Table 11: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

45 60 622 985 83 600 0.84 P,S,T,Z

45 60 624 985 83 600 0.84 P,S,T,Z

45 60 626 985 83 600 0.84 P,S,T,Z

55 74 620 990 100 735 0.79 P,S,T,Z

55 74 622 990 100 735 0.79 P,S,T,Z

55 74 624 990 100 735 0.79 P,S,T,Z

55 74 626 990 100 735 0.79 P,S,T,Z

N-pump, Premium Efficiency Motor (IE3)

14 Flygt 3301, 50Hz Technical Specification

Page 17: Flygt 3301, 50Hz - Lenntech

MT

WS004064A

0 50 100 150 200 250 300 3500

5

10

15

20

25

30

35

30

40

50

630

630

632

632

634

634

636

636

Q [l/s]

H [m]

P [kW]

MT

Table 12: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

45 60 632 985 83 600 0.84 P,S,T,Z

45 60 634 985 83 600 0.84 P,S,T,Z

45 60 636 985 83 600 0.84 P,S,T,Z

55 74 630 990 100 735 0.79 P,S,T,Z

55 74 632 990 100 735 0.79 P,S,T,Z

55 74 634 990 100 735 0.79 P,S,T,Z

55 74 636 990 100 735 0.79 P,S,T,Z

N-pump, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 15

Page 18: Flygt 3301, 50Hz - Lenntech

HT

WS004065A

0 20 40 60 80 100 120 140 1600

10

20

30

40

50

60

70

0

20

40

60

80

458

458

450

450

452

452

454

454

456

456

Q [l/s]

H [m]

P [kW]

HT

Table 13: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

55 74 452 1485 97 640 0.86 P,S,T,Z

55 74 454 1485 97 640 0.86 P,S,T,Z

55 74 456 1485 97 640 0.86 P,S,T,Z

55 74 458 1485 97 640 0.86 P,S,T,Z

70 94 450 1485 123 900 0.86 P,S,T,Z

70 94 452 1485 123 900 0.86 P,S,T,Z

70 94 454 1485 123 900 0.86 P,S,T,Z

70 94 456 1485 123 900 0.86 P,S,T,Z

70 94 458 1485 123 900 0.86 P,S,T,Z

Motor rating and performance curves 3301.860/.870These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

N-pump, Premium Efficiency Motor (IE3)

16 Flygt 3301, 50Hz Technical Specification

Page 19: Flygt 3301, 50Hz - Lenntech

MT

Q [l/s]

H [m]

2P [kW]

0 50 100 150 200 250 300 3500

5

10

15

20

25

30

35

20

30

40

50

MT

630

630

630

630

630

630

630

630

632

632

632

632

632

632

632

632

632

632

632

632

632

632

632

632

634

634

634

634634634634

634

634

634

634

634

634

636

636

636

636

636

636

636

636636

636

636636

636

636

WS007838A

Ratedpower, kW

Ratedpower, hp

Curve/Impeller No

Revolutions perminute, rpm

Ratedcurrent, A

Startcurrent, A

Power factor,cos φ

Installation

45 60 632 985 83 600 0.84 P,S

45 60 634 985 83 600 0.84 P,S

45 60 636 985 83 600 0.84 P,S

55 74 630 985 100 735 0.85 P,S

55 74 632 985 100 735 0.85 P,S

55 74 634 985 100 735 0.85 P,S

55 74 636 985 100 735 0.85 P,S

N-pump, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 17

Page 20: Flygt 3301, 50Hz - Lenntech

HT

Q [l/s]

H [m]

2P [kW]

0 20 40 60 80 100 120 1400

10

20

30

40

50

60

20

30

40

50

HT

460

460

460

460

460

460

460

460

462

462

462

462

462

462

462

462

464

464

464

464

464

464

464

464

466

466

466

466

466

466

466

466

468

468

468

468

468

468

468

468

WS007839A

Ratedpower, kW

Ratedpower, hp

Curve/Impeller No

Revolutions perminute, rpm

Ratedcurrent, A

Startcurrent, A

Power factor,cos φ

Installation

55 74 460 1485 97 675 0.87 P,S

55 74 462 1485 97 675 0.87 P,S

55 74 464 1485 97 675 0.87 P,S

55 74 466 1485 97 675 0.87 P,S

55 74 468 1485 97 675 0.87 P,S

70 94 460 1485 132 905 0.8 P,S

70 94 462 1485 132 905 0.8 P,S

70 94 464 1485 132 905 0.8 P,S

70 94 466 1485 132 905 0.8 P,S

70 94 468 1485 132 905 0.8 P,S

N-pump, Premium Efficiency Motor (IE3)

18 Flygt 3301, 50Hz Technical Specification

Page 21: Flygt 3301, 50Hz - Lenntech

Dimensions and Weight, StandardMotorDrawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your local sales and service representative for more information.

All dimensions are in mm.

Figure 1: LT, P-installation Figure 2: LT, P-installation

Dimensions and Weight, Standard Motor

Flygt 3301, 50Hz Technical Specification 19

Page 22: Flygt 3301, 50Hz - Lenntech

Figure 3: LT, S-installation

Figure 4: LT, T-installation Figure 5: LT, T-installation

Dimensions and Weight, Standard Motor

20 Flygt 3301, 50Hz Technical Specification

Page 23: Flygt 3301, 50Hz - Lenntech

Figure 6: LT, Z-installation Figure 7: LT, Z-installation

Figure 8: LT, Z-installation Figure 9: LT, Z-installation

Dimensions and Weight, Standard Motor

Flygt 3301, 50Hz Technical Specification 21

Page 24: Flygt 3301, 50Hz - Lenntech

Figure 10: MT, P-installation Figure 11: MT, S-installation

Figure 12: MT, T-installation Figure 13: MT, Z-installation

Dimensions and Weight, Standard Motor

22 Flygt 3301, 50Hz Technical Specification

Page 25: Flygt 3301, 50Hz - Lenntech

Figure 14: MT, Z-installation

Figure 15: HT, P-installation Figure 16: HT, S-installation

Dimensions and Weight, Standard Motor

Flygt 3301, 50Hz Technical Specification 23

Page 26: Flygt 3301, 50Hz - Lenntech

Figure 17: HT, T-installation Figure 18: HT, Z-installation

Figure 19: HT, Z-installation

Dimensions and Weight, Standard Motor

24 Flygt 3301, 50Hz Technical Specification

Page 27: Flygt 3301, 50Hz - Lenntech

Dimensions and Weight, PremiumEfficiency Motor (IE3)Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact your local sales and service representative for more information.

All dimensions are in mm.

Figure 20: LT, P-installation Figure 21: LT, S-installation

Dimensions and Weight, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 25

Page 28: Flygt 3301, 50Hz - Lenntech

Figure 22: LT, T-installation

Figure 23: LT, Z-installation Figure 24: LT, Z-installation

Dimensions and Weight, Premium Efficiency Motor (IE3)

26 Flygt 3301, 50Hz Technical Specification

Page 29: Flygt 3301, 50Hz - Lenntech

Figure 25: MT, P-installation Figure 26: MT, S-installation

Figure 27: MT, S-installation Figure 28: MT, T-installation

Dimensions and Weight, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 27

Page 30: Flygt 3301, 50Hz - Lenntech

Figure 29: MT, Z-installation Figure 30: MT, Z-installation

Figure 31: HT, P-installation Figure 32: HT, S-installation

Dimensions and Weight, Premium Efficiency Motor (IE3)

28 Flygt 3301, 50Hz Technical Specification

Page 31: Flygt 3301, 50Hz - Lenntech

Figure 33: HT, T-installation

Figure 34: HT, Z-installation Figure 35: HT, Z-installation

Dimensions and Weight, Premium Efficiency Motor (IE3)

Flygt 3301, 50Hz Technical Specification 29

Page 32: Flygt 3301, 50Hz - Lenntech

Xylem |’zīləm|

1) The tissue in plants that brings water upward from the roots2) A leading global water technology company

We're 12,500 people unified in a common purpose: creating innovativesolutions to meet our world's water needs. Developing new technologies thatwill improve the way water is used, conserved, and re-used in the future is centralto our work. We move, treat, analyze, and return water to the environment, andwe help people use water efficiently, in their homes, buildings, factories andfarms. In more than 150 countries, we have strong, long-standing relationshipswith customers who know us for our powerful combination of leading productbrands and applications expertise, backed by a legacy of innovation.

Visit our Web site for the latest version of this documentand more information

The original instruction is in English. All non-Englishinstructions are translations of the original instruction.

© 2012 Xylem Inc

883456_4.0_en-US_2015-01_TS_3301_50Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech