62
Technical Specification Flygt 3085, 50Hz info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Lenntech

Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Technical Specification

Flygt 3085, 50Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech

Page 2: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Table of Contents

1 C-pump, Standard Motor.......................................................................................................... 31.1 Product description............................................................................................................. 31.2 Motor rating and performance curves.............................................................................. 5

2 C-pump, Premium Efficiency Motor (IE3)................................................................................82.1 Product description............................................................................................................. 82.2 Motor rating and performance curves............................................................................ 10

3 D-pump......................................................................................................................................123.1 Product description........................................................................................................... 123.2 Motor rating and performance curves............................................................................ 14

4 F-pump.......................................................................................................................................174.1 Product description........................................................................................................... 174.2 Motor rating and performance curves............................................................................ 19

5 G-pump......................................................................................................................................215.1 Product description........................................................................................................... 215.2 Motor rating and performance curves............................................................................ 23

6 M-pump..................................................................................................................................... 256.1 Product description........................................................................................................... 256.2 Motor rating and performance curves............................................................................ 27

7 N-pump, Standard Motor........................................................................................................297.1 Product description........................................................................................................... 297.2 Motor rating and performance curves 3085.183/.092................................................. 327.3 Motor rating and performance curves 3085.060/.070/.160/.190/.760/.770.............34

8 N-pump, Premium Efficiency Motor (IE3)............................................................................. 388.1 Product description........................................................................................................... 388.2 Motor rating and performance curves 3085.820/.830................................................. 418.3 Motor rating and performance curves 3085.900/.910/.920/.930/.960/.970.............42

9 Dimensions and Weight, C-pump..........................................................................................439.1 Drawings............................................................................................................................. 43

10 Dimensions and Weight, D-pump....................................................................................... 4810.1 Drawings...........................................................................................................................48

11 Dimensions and Weight, F-pump........................................................................................5011.1 Drawings...........................................................................................................................50

12 Dimensions and Weight, G-pump....................................................................................... 5212.1 Drawings...........................................................................................................................52

13 Dimensions and Weight, M-pump.......................................................................................5313.1 Drawings...........................................................................................................................53

Table of Contents

Flygt 3085, 50Hz Technical Specification 1

Page 3: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

14 Dimensions and Weight, N-pump....................................................................................... 5514.1 Drawings...........................................................................................................................55

Table of Contents

2 Flygt 3085, 50Hz Technical Specification

Page 4: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

1 C-pump, Standard Motor1.1 Product description

Usage

A submersible pump for wastewater containing solids or fibered material, clean water, orsurface water.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Gray iron 3085.183 3085.092 MT — Medium head F, P, S, T, Z

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

T Vertical permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Z Horizontal permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Liquid temperature, warm water version Maximum 70°C (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

1 C-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 3

Page 5: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Feature Description

Frequency 50 Hz

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 1: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, gray 30B GJL-200

Wear ring Bronze C924 CC491K; CC492K

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

1 C-pump, Standard Motor

4 Flygt 3085, 50Hz Technical Specification

Page 6: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Denomination Material ASTM EN

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 2: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

1.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

1 C-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 5

Page 7: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

MT

WS005001A

Table 3: 400 V, 50 Hz, 3–phase

Ratedpower, kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Startingcurrent, A

Powerfactor, cosφ

Installation

0,9 1,2 632 940 2,9 11 0,65 F,P,S

0,9 1,2 634 940 2,9 11 0,65 F,P,S

0,9 1,2 636 940 2,9 11 0,65 F,P,S

1 1,3 436 1455 3,2 23 0,6 T,Z

1 1,3 438 1455 3,2 23 0,6 T,Z

1 1,3 440 1455 3,2 23 0,6 T,Z

1,3 1,7 434 1440 3,6 23 0,68 F,P,S

1,3 1,7 436 1440 3,6 23 0,68 F,P,S

1,3 1,7 438 1440 3,6 23 0,68 F,P,S

1,3 1,7 440 1440 3,6 23 0,68 F,P,S

1,4 1,9 434 1435 3,7 23 0,7 T,Z

1,4 1,9 436 1435 3,7 23 0,7 T,Z

1,4 1,9 438 1435 3,7 23 0,7 T,Z

1,4 1,9 440 1435 3,7 23 0,7 T,Z

2 2,7 432 1400 4,8 23 0,8 F,P,S

2 2,7 434 1400 4,8 23 0,8 F,P,S

2 2,7 436 1400 4,8 23 0,8 F,P,S

2 2,7 438 1400 4,8 23 0,8 F,P,S

2 2,7 440 1400 4,8 23 0,8 F,P,S

1 C-pump, Standard Motor

6 Flygt 3085, 50Hz Technical Specification

Page 8: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Table 4: 230 V, 50 Hz, 1–phase

Ratedpower, kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Startingcurrent, A

Powerfactor, cosφ

Installation

0,95 1,3 436 1410 7,2 28 0,86 F,P,S

0,95 1,3 438 1410 7,2 28 0,86 F,P,S

0,95 1,3 440 1410 7,2 28 0,86 F,P,S

1,5 2 434 1425 9,4 43 0,9 F,P,S

1,5 2 436 1425 9,4 43 0,9 F,P,S

1,5 2 438 1425 9,4 43 0,9 F,P,S

1,5 2 440 1425 9,4 43 0,9 F,P,S

1 C-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 7

Page 9: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

2 C-pump, Premium EfficiencyMotor (IE3)2.1 Product description

Usage

A submersible pump for wastewater containing solids or fibered material, clean water, orsurface water.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Gray iron 3085.800 3085.810 MT — Medium head F, P, S, T, Z

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

T Vertical permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Z Horizontal permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

2 C-pump, Premium Efficiency Motor (IE3)

8 Flygt 3085, 50Hz Technical Specification

Page 10: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Motor data

Feature Description

Motor type Line started permanent magnet motor (LSPM)

Frequency 50 Hz

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 5: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, gray 30B GJL-200

2 C-pump, Premium Efficiency Motor (IE3)

Flygt 3085, 50Hz Technical Specification 9

Page 11: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Denomination Material ASTM EN

Wear ring Bronze C924 CC491K; CC492K

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 6: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

2.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

2 C-pump, Premium Efficiency Motor (IE3)

10 Flygt 3085, 50Hz Technical Specification

Page 12: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

MT

Q [l/s]

H [m]

2P [kW]

0 4 8 12 16 200

1

2

3

4

5

6

7

0.0

0.4

0.8

1.2

MT

436

436

436

436

436

436

436

436

436

436

436

436

438

438

438

438

438

438

438

438

438

438

438

438

440

440

440

440

440

440

440

440

440

440

440

440

WS004982A

Table 7: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power factor,cos φ

Installation

1.6 2.1 436 1500 3.3 23 0.82 F,P,S,T,Z

1.6 2.1 438 1500 3.3 23 0.82 F,P,S,T,Z

1.6 2.1 440 1500 3.3 23 0.82 F,P,S,T,Z

2 2.7 436 1500 3.8 23 0.87 F,P,S,T,Z

2 2.7 438 1500 3.8 23 0.87 F,P,S,T,Z

2 2.7 440 1500 3.8 23 0.87 F,P,S,T,Z

2 C-pump, Premium Efficiency Motor (IE3)

Flygt 3085, 50Hz Technical Specification 11

Page 13: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

3 D-pump3.1 Product description

Usage

A submersible pump, with vortex hydraulic, for liquids containing solids and abrasivemedia, or light wastewater.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Gray iron 3085.183 3085.092 • MT — Mediumhead

• HT — High head

P, S

The pump can be used in the following installations:

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Liquid temperature, warm water version Maximum 70°C (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 1-phase or 3-phase

3 D-pump

12 Flygt 3085, 50Hz Technical Specification

Page 14: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Feature Description

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 8: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing,alternative 1

Cast iron, gray 35B GJL-250

Pump housing,alternative 2

Cast iron, gray, 45 HRC 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, gray 30B GJL-200

Impeller, alternative 3 Cast iron, gray 30B GJL-200

3 D-pump

Flygt 3085, 50Hz Technical Specification 13

Page 15: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Denomination Material ASTM EN

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 9: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

3.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

3 D-pump

14 Flygt 3085, 50Hz Technical Specification

Page 16: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

MT

WS005003A

Table 10: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

2 2,7 470 1400 4,8 23 0,8 P,S

2 2,7 472 1400 4,8 23 0,8 P,S

2 2,7 474 1400 4,8 23 0,8 P,S

2 2,7 485 1400 4,8 23 0,8 P,S

2 2,7 486 1400 4,8 23 0,8 P,S

2 2,7 487 1400 4,8 23 0,8 P,S

Table 11: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

1,5 2 472 1425 9,4 43 0,9 P,S

1,5 2 474 1425 9,4 43 0,9 P,S

1,5 2 486 1425 9,4 43 0,9 P,S

1,5 2 487 1425 9,4 43 0,9 P,S

3 D-pump

Flygt 3085, 50Hz Technical Specification 15

Page 17: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

HT

WS005004A

Table 12: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

2,4 3,2 276 2845 4,8 29 0,9 P,S

2,4 3,2 278 2845 4,8 29 0,9 P,S

3 D-pump

16 Flygt 3085, 50Hz Technical Specification

Page 18: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

4 F-pump4.1 Product description

Usage

A submersible pump for liquid manure, or heavily contaminated sewage and sludge. Theimpeller is S-shaped and has a cutting function.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

ChopperGray iron

3085.183 3085.092 • LT — Low head P, S

The pump can be used in the following installations:

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Liquid temperature, warm water version Maximum 70°C (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 1-phase or 3-phase

4 F-pump

Flygt 3085, 50Hz Technical Specification 17

Page 19: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Feature Description

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 13: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller Cast iron, nodular - GJS-400-18-LT

Suction cover Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

4 F-pump

18 Flygt 3085, 50Hz Technical Specification

Page 20: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Denomination Material ASTM EN

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 14: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

4.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

4 F-pump

Flygt 3085, 50Hz Technical Specification 19

Page 21: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

LT

WS005005A

Table 15: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

2 2,7 490 1400 4,8 23 0,8 P,S

2 2,7 491 1400 4,8 23 0,8 P,S

2 2,7 492 1400 4,8 23 0,8 P,S

Table 16: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

1,5 2 492 1425 9,4 43 0,9 P,S

4 F-pump

20 Flygt 3085, 50Hz Technical Specification

Page 22: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

5 G-pump5.1 Product description

Usage

A submersible pump designed for pumping ground water.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Gray iron 3085.183 3085.092 MT — Medium head F

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

5 G-pump

Flygt 3085, 50Hz Technical Specification 21

Page 23: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Feature Description

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 17: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller Cast iron, gray 35B GJL-250

Strainer bottom Stainless steel AISI 304 1.4301

Cutter plate Steel, stainless steel - -

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings Nitrile rubber (NBR) 70° IRH - -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

5 G-pump

22 Flygt 3085, 50Hz Technical Specification

Page 24: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Table 18: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Leakage sensor in the oil housing (CLS)• Leakage sensor in the stator housing (FLS)• Surface treatment (Epoxy)• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

5.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

5 G-pump

Flygt 3085, 50Hz Technical Specification 23

Page 25: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

MT

WS005006A

Table 19: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

0,77 1 242 2775 1,7 7,5 0,9 F

0,77 1 244 2775 1,7 7,5 0,9 F

Table 20: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

0,77 1 242 2785 3 13 0,9 F

0,77 1 244 2785 3 13 0,9 F

5 G-pump

24 Flygt 3085, 50Hz Technical Specification

Page 26: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

6 M-pump6.1 Product description

Usage

A submersible pump for wastewater containing solids that need to be macerated. Theimpeller is equipped with a grinder device.

Denomination

Type Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Gray ironGrinder

3085.172 3085.891 HT — High head F, H, P

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

H semipermanent, wet well quick connection suspended arrangement, incorporatingintegral non-return valve.

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 1-phase or 3-phase

6 M-pump

Flygt 3085, 50Hz Technical Specification 25

Page 27: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Feature Description

Starting method • Direct on-line• Star-delta• Soft starter

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 21: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller Cast iron, gray 30B GJL-200

Cutter wheel Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Cutter plate Steel, stainless steel - -

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings Nitrile rubber (NBR) 70° IRH - -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

6 M-pump

26 Flygt 3085, 50Hz Technical Specification

Page 28: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Table 22: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

6.2 Motor rating and performance curvesThese are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

6 M-pump

Flygt 3085, 50Hz Technical Specification 27

Page 29: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

HT

WS005007A

Table 23: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

2,4 3,2 250 2845 4,8 29 0,9 F,H,P

2,4 3,2 253 2845 4,8 29 0,9 F,H,P

2,4 3,2 254 2845 4,8 29 0,9 F,H,P

2,4 3,2 259 2845 4,8 29 0,9 F,H,P

1,8 2,4 254 2890 3,6 29 0,87 F,H,P

1,8 2,4 259 2890 3,6 29 0,87 F,H,P

Table 24: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Starting current,A

Power factor,cos φ

Installation

1,9 2,5 249 2915 12 61 0,87 F,H,P

1,9 2,5 254 2915 12 61 0,87 F,H,P

6 M-pump

28 Flygt 3085, 50Hz Technical Specification

Page 30: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

7 N-pump, Standard Motor7.1 Product description

Usage

A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids or long-fibered material. The pump is designed for sustained highefficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller isavailable as an option.

Denomination

Table 25: Adaptive N-hydraulic

Impeller material Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Hard-Iron™ 3085.060 3085.070 MT — Medium headSH — Super head

F, P, S, T, Z

Cast iron, gray 3085.160 3085.190 MT — Medium headSH — Super head

F, P, S, T, Z

Stainless steel 3085.760 3085.770 MT — Medium headSH — Super head

F, P, S, T, Z

Table 26: N-hydraulic

Impeller material Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Hard-Iron™ 3085.183 3085.092 MT — Medium head F, P, S, T, Z

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

T Vertical permanent, dry well arrangement with flange connection to the suction anddischarge piping.

7 N-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 29

Page 31: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Z Horizontal permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Liquid temperature, warm water version Maximum 70°C (158°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Squirrel-cage induction motor

Frequency 50 Hz

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Motor encapsulation

Motor encapsulation is in accordance with IP68.

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

7 N-pump, Standard Motor

30 Flygt 3085, 50Hz Technical Specification

Page 32: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Application Type

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 27: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474

Insert ring, alternative 1 Cast iron, gray 35B GJL-250

Insert ring, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 28: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Warm liquid version (non-explosion proof versions)• Leakage sensor in the stator housing (FLS)

7 N-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 31

Page 33: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

• Leakage sensor in the oil housing (CLS)• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

7.2 Motor rating and performance curves 3085.183/.092These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

MT

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 30 350

2

4

6

8

10

0.0

0.5

1.0

1.5

2.0

2.5

MT 3~

460/464

460/464

461

461/465

461/465

463/466

463/466

WS005008A

Table 29: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

1 1,3 463 1455 3,2 23 0,6 T,Z

1 1,3 466 1455 3,2 23 0,6 T,Z

1,3 1,7 461 1440 3,6 23 0,68 F,P,S

1,3 1,7 463 1440 3,6 23 0,68 F,P,S

1,3 1,7 465 1440 3,6 23 0,68 F,P,S

1,3 1,7 466 1440 3,6 23 0,68 F,P,S

1,4 1,9 461 1435 3,7 23 0,7 T,Z

7 N-pump, Standard Motor

32 Flygt 3085, 50Hz Technical Specification

Page 34: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

1,4 1,9 463 1435 3,7 23 0,7 T,Z

1,4 1,9 465 1435 3,7 23 0,7 T,Z

1,4 1,9 466 1435 3,7 23 0,7 T,Z

2 2,7 460 1415 5,2 27 0,73 F,P,S

2 2,7 461 1415 5,2 27 0,73 F,P,S

2 2,7 463 1415 5,2 27 0,73 F,P,S

2 2,7 464 1415 5,2 27 0,73 F,P,S

2 2,7 465 1415 5,2 27 0,73 F,P,S

2 2,7 466 1415 5,2 27 0,73 F,P,S

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 300

1

2

3

4

5

6

7

0.8

1.0

1.2

1.4

1.6

MT 1~

461

461

463

463

WS005009A

Table 30: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

1,5 2 461 1425 9,4 43 0,9 P,S

1,5 2 463 1425 9,4 43 0,9 P,S

7 N-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 33

Page 35: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

SH

Q [l/s]

H [m]

2P [kW]

0 4 8 12 16 200

4

8

12

16

20

24

1.5

2.0

2.5

SH

253

253

254

254

255

255

256

256

WS005010A

Table 31: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

2,4 3,2 253 2845 4,8 29 0,9 P,S

2,4 3,2 254 2845 4,8 29 0,9 P,S

2,4 3,2 255 2845 4,8 29 0,9 P,S

2,4 3,2 256 2845 4,8 29 0,9 P,S

7.3 Motor rating and performance curves3085.060/.070/.160/.190/.760/.770

These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

7 N-pump, Standard Motor

34 Flygt 3085, 50Hz Technical Specification

Page 36: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

MT

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 30 350

2

4

6

8

10

1.0

1.5

2.0

2.5

MT

460

460

461

461

462

462

463

463

WS005022A

Table 32: 400 V, 50 Hz, 3–phase

Ratedpower, kW

Rated power,hp

Curve/ImpellerNo

Revolutions perminute,rpm

Rated current,A

Startingcurrent, A

Powerfactor, cosφ

Installation

1 1,3 463 1455 3,2 23 0,6 T,Z

1,3 1,7 462 1440 3,6 23 0,68 F,P,S

1,3 1,7 463 1440 3,6 23 0,68 F,P,S

1,4 1,9 462 1435 3,7 23 0,7 T,Z

1,4 1,9 463 1435 3,7 23 0,7 T,Z

2 2,7 460 1400 4,8 23 0,8 F,P,S

2 2,7 461 1400 4,8 23 0,8 F,P,S

2 2,7 462 1400 4,8 23 0,8 F,P,S

2 2,7 463 1400 4,8 23 0,8 F,P,S

7 N-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 35

Page 37: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 300

1

2

3

4

5

6

7

0.8

1.0

1.2

1.4

1.6

MT

462

462

463

463

WS004116A

Table 33: 230 V, 50 Hz, 1–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

1.5 2.0 462 1425 9.4 43 0.9 F,P,S

1.5 2.0 463 1425 9.4 43 0.9 F,P,S

7 N-pump, Standard Motor

36 Flygt 3085, 50Hz Technical Specification

Page 38: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

SH

Q [l/s]

H [m]

2P [kW]

0 4 8 12 16 200

4

8

12

16

20

24

1.5

2.0

2.5

SH

253

253

253

253

254

254

254

254

255

255

255

255

256

256

256

256

WS004117A

Table 34: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

Ratedcurrent, A

Startingcurrent, A

Power factor,cos φ

Installation

2,4 3,2 253 2845 4,8 29 0,91 P,S

2,4 3,2 254 2845 4,8 29 0,91 P,S

2,4 3,2 255 2845 4,8 29 0,91 P,S

2,4 3,2 256 2845 4,8 29 0,91 P,S

2,4 3,2 253 2870 4,9 34 0,87 P,S

2,4 3,2 254 2870 4,9 34 0,87 P,S

2,4 3,2 255 2870 4,9 34 0,87 P,S

2,4 3,2 256 2870 4,9 34 0,87 P,S

7 N-pump, Standard Motor

Flygt 3085, 50Hz Technical Specification 37

Page 39: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

8 N-pump, Premium EfficiencyMotor (IE3)8.1 Product description

Usage

A submersible pump for efficient pumping of clean water, surface water, and wastewatercontaining solids or long-fibered material. The pump is designed for sustained highefficiency. For abrasive media, Hard-Iron™ is required. Stainless steel N-impeller isavailable as an option.

Denomination

Table 35: Adaptive N-hydraulic

Impeller material Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Cast iron, gray 3085.900 3085.910 MT — Medium headSH — Super head

F, P, S, T, Z

Hard-Iron™ 3085.920 3085.930 MT — Medium headSH — Super head

F, P, S, T, Z

Stainless steel 3085.960 3085.970 MT — Medium headSH — Super head

F, P, S, T, Z

Table 36: N-hydraulic

Impeller material Non-explosion proofversion

Explosion proofversion

Pressure class Installation types

Hard-Iron™ 3085.820 3085.830 MT — Medium head F, P, S, T, Z

The pump can be used in the following installations:

F Free standing semipermanent, wet well arrangement where the pump is placed on afirm surface.

P Semipermanent, wet well arrangement with the pump installed on two guide bars. Theconnection to the discharge is automatic.

S Portable semipermanent, wet well arrangement with hose coupling or flange forconnection to the discharge pipeline.

8 N-pump, Premium Efficiency Motor (IE3)

38 Flygt 3085, 50Hz Technical Specification

Page 40: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

T Vertical permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Z Horizontal permanent, dry well arrangement with flange connection to the suction anddischarge piping.

Application limits

Feature Description

Liquid temperature Maximum 40°C (104°F)

Depth of immersion Maximum 20 m (65 ft)

pH of the pumped liquid 5.5 – 14

Liquid density Maximum 1100 kg/m3

Motor data

Feature Description

Motor type Line started permanent magnet motor (LSPM)

Frequency 50 Hz

Power supply 1-phase or 3-phase

Starting method • Direct on-line• Star-delta• Soft starter• Variable Frequency Drive (VFD)

Number of starts per hour Maximum 30

Code compliance IEC 60034-1

Voltage variation • Continuously running: Maximum ±5%• Intermittent running: Maximum ±10%

Voltage imbalance betweenphases

Maximum 2%

Stator insulation class H (180°C, 356°F)

Motor encapsulation

Motor encapsulation is in accordance with IP68.

Cables

Application Type

Direct-on-line start or Y/D start with two cables Flygt SUBCAB® - a heavy duty 4 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 10 mm2 with unscreened controlcores.

Y/D start Flygt SUBCAB® - a heavy duty 7 cores motor power cablewith two twisted pair screened control cores. Conductorinsulation rating of 90°C, which allows for increasedcurrent. Superior mechanical strength and high abrasionand tear resistant. Chemical resistant within pH 3-10 andozone, oil, and flame resistant. Used up to 70°C watertemperature. Cables < 7G6 mm2 with unscreenedcontrol cores.

8 N-pump, Premium Efficiency Motor (IE3)

Flygt 3085, 50Hz Technical Specification 39

Page 41: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Application Type

Variable Frequency drive Screened Flygt SUBCAB® - a heavy duty 4 screened coresmotor power cable with four twisted pair screenedcontrol cores. Conductor insulation rating of 90°C, whichallows for increased current. Superior mechanicalstrength and high abrasion and tear resistant. Chemicalresistant within pH 3-10 and ozone, oil, and flameresistant. Used up to 70°C water temperature.

Monitoring equipment

Thermal contacts opening temperature 125°C (257°F)

Materials

Table 37: Major parts except mechanical seals

Denomination Material ASTM EN

Major castings Cast iron, gray 35B GJL-250

Pump housing Cast iron, gray 35B GJL-250

Impeller, alternative 1 Cast iron, gray 35B GJL-250

Impeller, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Impeller, alternative 3 Stainless steel, Duplex CD-4MCuN 10283:2010 -1.4474

Insert ring, alternative 1 Cast iron, gray 35B GJL-250

Insert ring, alternative 2 Cast iron, Hard-Iron™ A 532 IIIA GJN-HB555(XCR23)

Lifting handle Stainless steel AISI 316L 1.4404,1.4432, …

Shaft Stainless steel AISI 431 1.4057+QT800

Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti 1.4401,1.4404, …

O-rings, alternative 1 Nitrile rubber (NBR) 70° IRH - -

O-rings, alternative 2 Fluorinated rubber (FPM) 70°IRH

- -

Oil, part no 901752 Medical white oil of paraffintype. Fulfills FDA 172.878 (a)

- -

Table 38: Mechanical seals

Alternative Inner seal Outer seal

1 Carbon/ Aluminum oxide Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide

3 Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Corrosion resistant cementedcarbide/ Corrosion resistantcemented carbide

Surface treatment

Priming Finish

Painted with a primer, see internal standardM0700.00.0002

Navy gray color NCS 5804-B07G. Two-component high-solid top coating, see internal standard M0700.00.0004for standard painting and M0700.00.0008 for specialpainting.

Options

• Leakage sensor in the stator housing (FLS)• Leakage sensor in the oil housing (CLS)

8 N-pump, Premium Efficiency Motor (IE3)

40 Flygt 3085, 50Hz Technical Specification

Page 42: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

• Surface treatment (Epoxy)• Zinc anodes• Other cables

Accessories

Discharge connections, adapters, hose connections, and other mechanical accessories

Electrical accessories such as pump controller, control panels, starters, monitoring relays,cables

8.2 Motor rating and performance curves 3085.820/.830These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

MT

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 30 350

2

4

6

8

10

0.0

0.5

1.0

1.5

2.0

MT

461

461

461

461

461

461

462

462

462

462

462

462

462

462

462

462

462

462

463

463

463

463

463

463

463

463

463

463

463

463

WS004984A

Table 39: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power factor,cos φ

Installation

1.6 2.1 462 1500 3.3 23 0.82 P,S,T,Z

1.6 2.1 463 1500 3.3 23 0.82 F,P,S,T,Z

2 2.7 461 1500 3.8 23 0.87 P,S,T,Z

2 2.7 462 1500 3.8 23 0.87 P,S,T,Z

2 2.7 463 1500 3.8 23 0.87 F,P,S,T,Z

8 N-pump, Premium Efficiency Motor (IE3)

Flygt 3085, 50Hz Technical Specification 41

Page 43: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

8.3 Motor rating and performance curves3085.900/.910/.920/.930/.960/.970

These are examples of motor rating and curves. For more information, please contactyour local sales and service representative.

Star-delta starting current is 1/3 of Direct on-line starting current.

MT

Q [l/s]

H [m]

2P [kW]

0 5 10 15 20 25 30 350

2

4

6

8

10

0.8

1.2

1.6

2.0

MT

461

461

462

462

462

462

463

463

463

463

WS007633A

Table 40: 400 V, 50 Hz, 3–phase

Rated power,kW

Rated power,hp

Curve/Impeller No

Revolutionsper minute,rpm

RatedCurrent, A

Start current,A

Power Factor,cos φ

Installation

1.6 2.1 462 1500 3.3 23 0.82 F,P,S

1.6 2.1 463 1500 3.3 23 0.82 F,P,S

2 2.7 461 1500 3.8 23 0.87 F,P,S

2 2.7 462 1500 3.8 23 0.87 F,P,S

2 2.7 463 1500 3.8 23 0.87 F,P,S

8 N-pump, Premium Efficiency Motor (IE3)

42 Flygt 3085, 50Hz Technical Specification

Page 44: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

9 Dimensions and Weight, C-pump9.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 1: LT, P-installation Figure 2: LT, P-installation

9 Dimensions and Weight, C-pump

Flygt 3085, 50Hz Technical Specification 43

Page 45: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 3: LT, S-installation Figure 4: LT, S-installation

Figure 5: MT, F-installation Figure 6: MT, P-installation

9 Dimensions and Weight, C-pump

44 Flygt 3085, 50Hz Technical Specification

Page 46: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 7: MT, P-installation Figure 8: MT, P-installation

Figure 9: MT, S-installation Figure 10: MT, S-installation

9 Dimensions and Weight, C-pump

Flygt 3085, 50Hz Technical Specification 45

Page 47: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 11: MT, T-installation Figure 12: MT, T-installation

Figure 13: MT, Z-installation Figure 14: HT, P-installation

9 Dimensions and Weight, C-pump

46 Flygt 3085, 50Hz Technical Specification

Page 48: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 15: HT, P-installation Figure 16: HT, S-installation

9 Dimensions and Weight, C-pump

Flygt 3085, 50Hz Technical Specification 47

Page 49: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

10 Dimensions and Weight, D-pump10.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 17: MT, P-installation Figure 18: MT, P-installation

10 Dimensions and Weight, D-pump

48 Flygt 3085, 50Hz Technical Specification

Page 50: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 19: MT, S-installation Figure 20: MT, S-installation

Figure 21: HT, P-installation Figure 22: HT, S-installation

10 Dimensions and Weight, D-pump

Flygt 3085, 50Hz Technical Specification 49

Page 51: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

11 Dimensions and Weight, F-pump11.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 23: J-installation Figure 24: P-installation

11 Dimensions and Weight, F-pump

50 Flygt 3085, 50Hz Technical Specification

Page 52: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 25: S-installation

11 Dimensions and Weight, F-pump

Flygt 3085, 50Hz Technical Specification 51

Page 53: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

12 Dimensions and Weight, G-pump12.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 26: F-installation

12 Dimensions and Weight, G-pump

52 Flygt 3085, 50Hz Technical Specification

Page 54: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

13 Dimensions and Weight, M-pump13.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 27: F-installation Figure 28: H-installation

13 Dimensions and Weight, M-pump

Flygt 3085, 50Hz Technical Specification 53

Page 55: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 29: P-installation

13 Dimensions and Weight, M-pump

54 Flygt 3085, 50Hz Technical Specification

Page 56: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

14 Dimensions and Weight, N-pump14.1 Drawings

All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg).Contact a local sales and service representative for more information.

All dimensions are in mm.

Figure 30: MT, F-installation Figure 31: MT, P-installation

14 Dimensions and Weight, N-pump

Flygt 3085, 50Hz Technical Specification 55

Page 57: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 32: MT, P-installation Figure 33: MT, P-installation

Figure 34: MT, S-installation Figure 35: MT, S-installation

14 Dimensions and Weight, N-pump

56 Flygt 3085, 50Hz Technical Specification

Page 58: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 36: MT, T-installation Figure 37: MT, T-installation

Figure 38: MT, Z-installation Figure 39: SH, P-installation

14 Dimensions and Weight, N-pump

Flygt 3085, 50Hz Technical Specification 57

Page 59: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Figure 40: SH, S-installation Figure 41: SH, T-installation

Figure 42: SH, T-installation Figure 43: SH, Z-installation

14 Dimensions and Weight, N-pump

58 Flygt 3085, 50Hz Technical Specification

Page 60: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version
Page 61: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version
Page 62: Flygt 3085, 50Hz - Lenntech · A submersible pump for wastewater containing solids or fibered material, clean water, or surface water. Denomination Type Non-explosion proof version

Xylem |’zīləm|

1) The tissue in plants that brings water upward from the roots2) A leading global water technology company

We’re a global team unified in a common purpose: creating innovative solutionsto meet our world's water needs. Developing new technologies that will improvethe way water is used, conserved, and re-used in the future is central to our work.We move, treat, analyze, and return water to the environment, and we helppeople use water efficiently, in their homes, buildings, factories and farms. Inmore than 150 countries, we have strong, long-standing relationships withcustomers who know us for our powerful combination of leading product brandsand applications expertise, backed by a legacy of innovation.

Visit our Web site for the latest version of this documentand more information

The original instruction is in English. All non-Englishinstructions are translations of the original instruction.

© 2012 Xylem Inc

883448_4.0_en-US_2016-11_TS_3085_50Hz

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech