Flexi BSC Commissioning

1

1 © Nokia Siemens Networks RN23274EN14GLN1

Flexi BSC & TCMS3i CommissioningRG10 (BSS)

Flexi BSC Commissioning

Page 2: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

2

2 © Nokia Siemens Networks RN23274EN14GLN1

Module objectives

After completing this module, the participant should be able to:• Commission the Flexi BSC

• Configure LANU

• Commission ESB

• Commission STMU

• Recommission BSC3i

• Verify that the Flexi BSC commissioning is well done• List the major steps used to commission the BSC equipment• Use all tools needed in the commissioning process• Perform commissioning following instructions and manuals• Demonstrate how to change the states of the functional units• Fault handling

Page 3: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

3

3 © Nokia Siemens Networks RN23274EN14GLN1

OverviewPurpose

• The purpose of the commissioning tests is to ensure that the BSC will operate correctly in the GSM network.

• When the commissioning tests have been performed in an acceptable manner, the BSC can be taken into traffic.

• Depending on the configuration, the commissioning of Flexi BSC takes around 3-5 working days.

Page 4: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

4

4 © Nokia Siemens Networks RN23274EN14GLN1

OverviewPrerequisites for BSC commissioning

• The BSC has passed the factory acceptance test

• The installation has to be accepted

• The files associated with the configuration are ready on the hardisksof the BSC

• The site has been built and prepared according to Flexi BSC, Release S14, Site Documentation

• Documents needed for commissioning:– S14 Hardware Revision List

– Interconnection Cables in Flexi BSC

– Pre-Processor Program Information in BSS14 Release Documentation

– Jumper Settings of the Cartridges in Flexi BSC and TCSM3i

– Jumper Settings of the Plug-in Units in Flexi BSC

Page 5: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

5

5 © Nokia Siemens Networks RN23274EN14GLN1

OverviewTools Required for BSC Commissioning

• Two terminal

• Hex calculator

• BSC Commissioning tool set NSN code: CS77580.05

• Jumper links

• Release documentation on PC

• New software on an USB memory stick

• All delivered Change Deliveries (installed after the commissioning)

• Customer Specific Disk including PRFILE, FIFILE, and license files

• Empty USB memory stick (if DCAR PIU used), or rewriteable MO disk (if ODPU PIU used).

Reference: Commissioning BSC3i (DN02199145, issue 6-1) on Nokia BSC3i, Rel. S13, Site Documentation, v.3

Page 6: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

6

6 © Nokia Siemens Networks RN23274EN14GLN1

BSC Commissioning ProcedureBSC3i 660 S11.5 Commissioning Procedure

Checking the HW

Checking the HW

Monitoring the Start-up

Monitoring the Start-up

Opening the first MML Session

Opening the first MML Session

Clock Equipment Checking

Clock Equipment Checking

Hardware Configuration

Checking

Hardware Configuration

Checking

Copying additional SW

and setting time zone

Copying additional SW

and setting time zone

SW version verifying

SW version verifying

I/O System Checking

I/O System Checking

Message Bus

Checking

Message Bus

Checking

Maintenance System

Checking

Maintenance System

Checking

11 22 33 44

88 77 66 55

10101111

ESB Switch Checking

ESB Switch Checking

99

Page 7: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

7

7 © Nokia Siemens Networks RN23274EN14GLN1

BSC Commissioning ProcedureBSC3i 1000/2000 S13 Commissioning Procedure

Checking the HW

Checking the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-upMonitoring the Start-up

Maintenance System

Checking

Maintenance System

Checking

ESB Switch Checking

ESB Switch Checking

SW version verifying

SW version verifying

Copying additional SW

and setting time zone

Copying additional SW

and setting time zone

I/O System Checking

I/O System Checking

EMB Checking

EMB Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration

Checking

Hardware Configuration

Checking

New New procedure in procedure in S.12S.12

11 22 33 44

88 77 66 55

99 1010 1111

Note :

For BSC3i 1000/2000 Commissioning, there are two new checking procedures: EMB checking (replacing Message Bus Checking), compare to BSC3i 660 commissioning procedure.

Reference: Commissioning BSC3i (DN02199145, issue 6-1) on Nokia BSC3i, Rel. S13, Site Documentation, v.3

Page 8: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

8

8 © Nokia Siemens Networks RN23274EN14GLN1

BSC Commissioning ProcedureFlexi BSC S14 Commissioning Procedure

Checking the HW

Checking the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-upMonitoring the Start-up

Maintenance System

Checking

Maintenance System

Checking

ESB Switch Checking

ESB Switch Checking

SW version verifying

SW version verifying

Copying additional SW

and setting time zone

Copying additional SW

and setting time zone

I/O System Checking

I/O System Checking

EMB Checking

EMB Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration

Checking

Hardware Configuration

Checking

No new No new procedure in procedure in S.14 for Flexi S.14 for Flexi BSCBSC

11 22 33 44

88 77 66 55

99 1010 1111

Note :

For BSC3i 1000/2000 Commissioning, there are two new checking procedures: EMB checking (replacing Message Bus Checking), compare to BSC3i 660 commissioning procedure.

Page 9: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

9

9 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the Hardware

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

Checking the Hardware

1. Internal cables

2. Interchangeability code

3. EPROM version

4. Jumper Settings

5. DIP Switches

6. FLASH version

7. Power Supply

8. Peripheral units

Page 10: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

10

10 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking overview (1/2)

Compare the internal cabling to the interconnection cables list in Interconnection Cables in Flexi BSC in Site Documentation to make sure that:

• The cable are connected to the right position

• The connection are made properly

• The cables are installed and locked correctly

Page 11: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

11

11 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking overview (2/2)

• Internal cable checking table can be found in the Interconnection Cables in Flexi BSC in RG10 Operating Document or Flexi BSC, Rel. S14, Site Documentation.

• Cable listings in the Interconnection Cables in Flexi BSC are categorized as follow:

1. BSCC Cabinet of first-delivery Flexi BSC

2. Upgrading BSCC cabinet of first-delivery BSC3i 1000/2000 to Flexi BSC

3. Upgrading BSCC cabinet of BSC3i 1000/2000 (upgraded from BSC3i 660) to Flexi BSC

4. Upgrading BSCC cabinet of BSC3i 660 directly to Flexi BSC

5. Upgrading BSCD cabinet of BSC3i 2000 to Flexi BSC

6. Upgrading transmission protection to equipment protection for ETS2 and ETIP1-A

• For the Flexi BSC new delivery, user has to check the cabling based on table which are on category 1 & 6.

• Category 6 is used if user implement the ETS2 or ETIP1-A with equipment protection (optional), in which there are some cables should be moved and added. Also new address modules should be added

Page 12: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

12

12 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – interconnection cable

The intracabinet cables include the following cables:• Power supply cables• Alarm and timing cables• Ethernet message bus cables• Message bus cables• SCSI cables

• Cables attached to cabling panel on the top of the cabinet (small CPETx panels, CPRJ45-A)

• PCM cables• LAN cables• Switch Control Bus (SCBUS) cables• Supervision Bus (SBUS) cables• Changeover Signal (CGS) cables• Changeover (CG) cables• Hotlink cables• Synchronisation (SYNC) cables

• Cables between the BSCC cabinet and the optional cabling cabinet (small and large CPETxpanels)

BSCC

Rear view

Page 13: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

13

13 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – interconnection cable

• The small CPETx panels used at the BSCC cabinet top are optional and ordered separately.

• The small and the large CPETx panels used in the optional cabling cabinet are delivered with the cabinet.

• Three cabling cabinet options are available:

– Cabling cabinet 2 PCMs / cable (connector panels CPETS-G and CPETS-H)

– Cabling cabinet 1 PCM / cable (connector panels CPETS-E and CPETS-F)

– Cabling cabinet coaxial PCMs (connector panels CPETC-E and CPETC-F)

• Intercabinet cables are used in a upgraded Flexi BSC that has been upgraded from BSC3i 2000.

BSCC

Rear view

Note :

In S13 first deliveries from the second half of 2008 onwards, the small CPETx panels used at the BSCC or BSCD cabinet top are optional and ordered separately.

Small and large CPETx panels used in the optional cabling cabinet are delivered with the cabinet.

There are three cabling cabinet options:

•cabling cabinet with balanced ET panels with two PCMs in one cable (small CPETS-G and large CPETS-H)

•cabling cabinet with balanced ET panels with one PCM in one cable (small CPETS-E and large CPETS-F)

•cabling cabinet with unbalanced ET panels (small CPETC-E and large CPETC-F)

The cable lists are organised in the following sections:

•S13 and S12 first delivery

•S12 upgrade instructions

•S11.5 first delivery

•S11.5 upgrade instructions

•Previous deliveries

Page 14: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

14

14 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – interconnection cable

• The tables of the interconection cables are intracabinet cables of the Flexi BSC and most of the intercabinet cables of the BSC3i.

• For exceptions, that is the cabling between the BSC3i part (BSC3i 1000/2000 or Flexi BSC) and the TCSA cabinet in the combined BSC3i/TCSM3i installation.

• Each cable has its individual number. This number and the address of both ends of the cable are given.

• Both the name of the functional unit to which the end of the cable is connected, and its co-ordinate are given in a table. The columns in the tables are used as follows:

Page 15: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

15

15 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – interconnection cable

Equipping No. shows the individual number of the cable. Both ends of the cable are marked with a label with this number on it.

Cabinet shows the name of the cabinet where the cable is connected.

FU or Panel shows the name of the functional unit or panel where the cable is connected

Position or Connector shows the co-ordinate of the connector where the cable is connected.

Type shows the type number of the cable. The type of the cable and connectors are coded in the first three or four letters and the length of the cable is shown in the following three numbers. The length is given in centimeters if there is a letter C after the three numbers, and in decimeters if there is no letter after the three number

Use shows the use of the cable.

Note shows the alternative configurations, if any.

Note:

List of abbreviation:

AL Alarm signal

CG Changeover

CGS Changeover Group Switch

CLK Clock signal

EMB Ethernet Message Bus signal

ET Exchange Terminal signal

LAN Local Area Network interface

LPT Line Printer

MB Message Bus signal

MDF Main Distribution Frame

PCM Pulse Code Modulation signal

SYNC Synchronisation signal

SBUS Supervision Bus signal

SCBUS Switch Control Bus signal

SCSI Small Computer Systems Interface signal

VDU Video Display Unit

V.24, X.21, V.35 Interface types defined by ITU-T

Page 16: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

16

16 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – how to identify cartridge, connector and cables

2 mm Hard Metric cartridges

Example :

Page 17: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

17

17 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInternal Cable Checking – how to identify cartridge, connector and cables

Euroconnector Cartridges

Example :

Page 18: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

18

18 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeable Code Checking

Place of manufacture

Year and week of manufacture

Factory identification

Serial number

Question: Where are the interchangeability codes listed?

Question: What type of unit is used in BSC applications?

Page 19: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

19

19 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (1/2)

• ICC (Interchangeability Code), Jumper Setting and DIP Switch are checked both for Cartridges and PIU.

• Hardware Revision List document consist of hardware list which are compatible with certain type of BSC (include Flexi BSC). Here is the list of the cartridges and PIU CIC for Flexi BSC

• For Jumper setting instruction, can be found in the following documents:

– Jumper Settings of the Cartridges in Flexi BSC

– Jumper Settings of the Plug-in Units in Flexi BSC and TCSM3i

Cartridges for Flexi BSC

PIUs for Flexi BSC

Page 20: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

20

20 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (2/2)

SGC1C-A - GSW and general TDM cartridge

W1

• Settings on jumper block W1 are used for setting the operating mode of the CL3TG-UA plug-in unit.

• Normally, the jumpers are installed between pins 2 and 3 (state 1) (External reference signal 2, termination for 120 ohm balanced interface)

• Default synchronization cables are located:

Page 21: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

21

21 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (1/6)

• AS7-D Plug-in Unit– The AS7-D has two vendors (Advantech & RadiSys) that differ in layout but

are identical in function

Advantech RadiSys

Page 22: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

22

22 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (2/6)

• AS7-D Plug-in Unit (cont’d)

Advantech

DIP Switch

Page 23: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

23

23 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (3/6)

SWPRO-C plug-in unit

DIP Switch

Page 24: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

24

24 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (4/6) Example for ET16 PIU

W2

P5

P4

P2

P1

Interchangeability code setting (SW2)

Jumper Setting

Reference:•Jumper Settings of the Plug-in Units in BSC3i and in TCSM3i (DN01154825 Issue 6-1)

•Jumper Settings of the Cartridges in BSC3i and TCSM3i (DN01154813 Issue 4-0)

Question: Name 4 plug in units that have jumper settings for

interchangeability code

Page 25: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

25

25 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (5/6) - Example for PCU2-E PIU

• Check the jumper setting:

W12

W13

W1

SW1

Page 26: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

26

26 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareInterchangeability code, Jumper Settings, DIP Switches (6/6) - Example for PCU2-E PIU

Default value

(W1) for PCU-E in Flexi BSC

W13 Standard setting for PCU-E in Flexi BSC

Page 27: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

27

27 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwareEPROM and FLASH version checking

• EPROM version and FLASH version can be found in S14 Preprocessor Information in release documentation along with Software Release package.

• Here is the list related to Flexi BSCReplaceable EPROM software versions

Programmable FLASH boot software versions

Page 28: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

28

28 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwarePower Supply Checking

Power connected at connectorblock on top of cabinet

Voltage requirement for BSC3i

Use multimeter to check the voltage

Power connected at connectorblock on top of cabinet

Power divider in front of the cabinet

Power divider in back of the cabinet

Page 29: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

29

29 © Nokia Siemens Networks RN23274EN14GLN1

Step 1 – Checking the HardwarePeripheral Unit: VDU, Printer Setting

• The purpose of this test is to check the strappings and setting made in the factory, and also perform internal tests in units which are equipped with test functions.

• For VDU setting:

• Connect the female connector to the VDU and join the free pins on the male connector with strapping wire.

• Type some text on the keyboard. The terminal is OK if the typed text is echoed to the screen

• If no text is displayed, the VDU is faulty.

• For printer setting:

• Perform internal tests on those printers that are equipped with test functions

80Line length

23Page length

EvenParity

2Stop bits

7Data bits

9600Baud rate

80Line length

65Page length

EvenParity

2Stop bits

7Data bits

9600Baud rate

Page 30: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

30

30 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML Command

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

ENTER USERNAME < SYSTEM

ENTER PASSWORD < ******

BSC3i BSC31-LAB 2007-01-17 14:31:10

WELCOME TO THE DX 200 SERIES DIALOGUE

MAIN LEVEL COMMAND <___>

Opening the first MML Session

Opening the first MML Session

22

Username : SYSTEM

Password : SYSTEM

Page 31: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

31

31 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandMML in Commissioning

• MML = Man Machine Language

• Command language

• Manage the operation of the BSC

• I/O syntax follows CCITT

recommendations.

Page 32: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

32

32 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandGeneral

• Organised in a three level command hierarchy.

• ON-LINE help.

• Own MML program for every MML command group.

• The MMI system loads the MML programs from a disk into the RAM when entered to the command group level.

Main Level

Command Class Level

Command Group Level

“D” “S” “I” “C” “C” “I”

U R

US RRRCUD

“U”“R”

“R”“C”

“S”

“D”

Commands

“ZRCI”

“ZR”

Command: USI

OMU

XY

Page 33: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

33

33 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandMML language hierarchy

PASSWORD

MAIN LEVEL

COMMANDCLASS LEVEL

COMMANDGROUP LEVEL

COMMANDSList unitinfo

Int. partialunit tests

Stopcurrent

test

...

A.. U..

AB. AH. US. UD.

ABO ABB AHO AHP USI USL UDI UDS

“A”

“B”

“U”

“Z;”

“Z;”

Print alarm

currently on

Blockalarms

Print alarms

currently blocked

Print alarm

history

Interrogateworking

state

Page 34: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

34

34 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandCommand class menu

< Z?

BSC3i BSC31-LAB 2007-01-25 15:19:45

MAIN LEVEL

? ..... DISPLAY MENU

A ..... ALARM SYSTEM ADMINISTRATION

C ..... ROUTING STATE ADMINISTRATION

D ..... SYSTEM SUPPORT AND COMMUNICATION

E ..... CELLULAR RADIO NETWORK ADMINISTRATION

F ..... FRAME RELAY ADMINISTRATION

I ..... I/O SYSTEM ADMINISTRATION

N ..... SS7 NETWORK ADMINISTRATION

O ..... SUPPLEMENTARY SS7 NETWORK ADMINISTRATION

Q ..... O&M NETWORK ADMINISTRATION

R ..... ROUTING ADMINISTRATION

T ..... TRAFFIC ADMINISTRATION

U ..... UNIT ADMINISTRATION

W ..... SYSTEM CONFIGURATION ADMINISTRATION

Y ..... SYSTEM SUPERVISION

Z; .... END DIALOGUE/DESTINATION SELECTION (:)

Page 35: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

35

35 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandCommand group menu

< U?

BSC3i BSC31-LAB 2007-01-25 15:17:43

SYSTEM SUPPORT AND COMMUNICATION

? ..... DISPLAY MENU

B ..... RADIO NETWORK TEST HANDLING

D ..... DIAGNOSTICS HANDLING

S ..... WORKING STATE AND RESTART HANDLING

Z; .... RETURN TO MAIN LEVEL

UNIT ADMINISTRATION COMMAND <U__>

Page 36: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

36

36 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandCommand menu

UNIT ADMINISTRATION COMMAND <U__>< S?

BSC3i BSC31-LAB 2007-01-25 15:17:43

WORKING STATE AND RESTART HANDLING COMMANDS

? ... DISPLAY MENU

C: ... CHANGE UNIT STATE

T: ... CHANGE UNIT INFO

W: ... WARM UP SPARE UNIT

I: ... INTERROGATE UNIT STATE

L: ... LIST UNITS IN SPECIFIED STATE OR INFO

U: ... RESTART UNIT

S: ... RESTART SYSTEM

Z; ... RETURN TO MAIN LEVEL

WORKING STATE AND RESTART HANDLING COMMAND <US_>

Page 37: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

37

37 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandMML command syntax

Command

ZABC: Parameter Block : Parameter Block :;

.... : Parameter, Parameter, ..... , :...

Parameter Type

.. : P1, P2, P3, , P5 : ...

1. Name Defined

.. : UNIT = OMU, DEV = LPT : ...

or: .. : DEV = LPT, UNIT = OMU : ...2. Position Defined

Omitted Parameter = DEFAULT

Page 38: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

38

38 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandPunctuation marks

: Pass or End Parameter Block

; End of Command --> EXECUTION

, Separation of parameters

? Menu or Parameter Information

% Wildcard(e.g. SW % = all names with SW .... )

Page 39: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

39

39 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandUsage of &, &&,-

& => AND&& => UP TO- => Timeslot TSL

PCM 3 AND 5 3 & 5

PCM 3 TSL 1 AND TSL 8 3 - 1 & - 8

PCM 3 UP TO 8 3 && 8

3 - 1 && - 8PCM 3 TSL 1 UP TO TSL 8

Examples:

Page 40: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

40

40 © Nokia Siemens Networks RN23274EN14GLN1

Step 2 – Opening the first MML CommandLine editor commands

CTRL A => Change mode CTRL B => Edit prev command

CTRL D => Cursor left CTRL E => Cursor end of line

CTRL F => Cursor right CTRL G => Cursor down

CTRL H => Cursor home CTRL I => Cursor up

CTRL K => Change language CTRL L => Delete character

CTRL N => Curs beg of param block CTRL O => Hardcopy

CTRL P => Page mode on/off CTRL Q => Cont. outputting

CTRL S => Pause outputting CTRL T => Output ringbuffer

CTRL U => Empty edit buffer CTRL X => Jump to CMD group level

CTRL Y => Interrupt CTRL Z => Del chars in edit buffer

BREAK => End of dialog CTRL 4 => MML testmode on/off

CTRL 7 => DX error description CTRL W => Display line editor commands

Page 41: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

41

41 © Nokia Siemens Networks RN23274EN14GLN1

Step 3 – Monitoring the Startup

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

1.1. Startup OMUStartup OMU

2.2. Startup Startup MCMUsMCMUs

3.3. Startup Startup BCSUsBCSUs

Monitoring the Start-upMonitoring the Start-up

33

Page 42: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

42

42 © Nokia Siemens Networks RN23274EN14GLN1

Step 3 – Monitoring the StartupStart-up of the OMU

• Ensure BSC printers and VDU connected

• Power up OMU cartridge

• Use RCBUGG in Service Terminal Emulator (to monitor unit state)

• Restart OMU

• Monitor Startup

Page 43: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

43

43 © Nokia Siemens Networks RN23274EN14GLN1

Step 3 – Monitoring the StartupStart-up of MCMU and BCSU

Start the MCMU Then the BCSU

Note :

•Check that the working state of the MCMU is WO-EX or SP-EX during the start-up of the system.

•Check that the working state of the BCSU is WO-EX or SP-EX during the start-up of the system.

Page 44: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

44

44 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System Checking

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

1.1. Power Supply of Mass Power Supply of Mass

memory Devices memory Devices

2.2. State of I/O devicesState of I/O devices

I/O System Checking

I/O System Checking

44

Page 45: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

45

45 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingTesting power system of the WDU

1. Check the state of the WDU.ZISI::WDU,0; WO-BU

2. Prevent file update to diskZDUP:OMU:NO,:;

3. Disconnect the powerpull the switch in HDSAM-A one step out

4. Remove the WDUpull out the HDSAM-A disk from the DCAR1-A

5. Check the state of the alarm in the MO drive.

ZISI::WDU,0; TE-ID and alarm 2692 is set

6. Reconnect the Power

7. Change the state of WDU with ZISC TE-IDWO-IDWO-BU

8. Resume file update to diskZDUR:OMU;

9. Check the state of the alarm in the WDUZISI::WDU,0; TE-ID and alarm 2692

is cancelled10.Repeat the steps 1-9 with

WDU1

DCAR1

Page 46: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

46

46 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingWorking states of I/O devices

WO - BU WORKING BUSY: WO I/O reserved

WO - ID WORKING IDLE: WO I/O free

WO - CL WORKING CLOSING: btw WO-BU & WO-ID

BL - SY BLOCKED BY SYSTEM: not ready, faulty

BL - US BLOCKED BY USER: user blocks it

TE - AC TEST ACTIVE: testing now

TE - ID TEST IDLE: ready to test

MI - SY MISSING BY SYSTEM: system not recognize

MI - US MISSING BY USER: before we remove a device

OFFLINE means Device connected but not power on

Page 47: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

47

47 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingNormal State of I/O devices

WDU, FDU & UMS HD/FD must have info all the time

VDU & LPT They must be free for any access

VTP & VPP Connection must be established to a remote I/O

WO-BU

WO-ID

WO-ID

Note:

LPT = Line printer

VDU = Display unit

WDU = hard disk unit

VTP = Virtual Terminal

VPP = Virtual Printer Protocol

VDS = Virtual Data Storing device

UMS = USB Mass Storage

Page 48: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

48

48 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingI/O device working state commands

< ZIS?

LOADING PROGRAM VERSION 11.4-0

BSC3i BSC31-LAB 2007-01-25 14:26:57

I/O DEVICE WORKING STATE COMMANDS

? ..... DISPLAY MENU

C: ..... CHANGE I/O DEVICE STATE

I: ..... INTERROGATE I/O DEVICE INFO

L: ..... LIST I/O DEVICES IN SPECIFIED STATE

M: ..... MODIFY SPARE DEVICE OF I/O DEVICE

K: ..... MODIFY/INTERROGATE SCSI ADDRESS OF MTU

F: ..... CHANGE FUNCTIONAL MODE OF CTU

Z; ..... RETURN TO MAIN LEVEL

Page 49: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

49

49 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingUnit states

Separated from normal operation and maintenanceAs above

WO-EX = Active unitWO-RE = Active, but restartingBL-EX = Blocked, executing (uncompleted tasks)BL-ID = Blocked, idle (all tasks finished)BL-RE = Blocked, restartingSP-EX = Spare unitSP-RE = Spare and restartingSP-UP = Spare and updating work files from the active unitTE-EX = Testing allowedSE-OU =SE-NH =

Page 50: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

50

50 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingChange Unit States

WO-EX

SE-NHSE-OU

TE-EXSP-EX

Page 51: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

51

51 © Nokia Siemens Networks RN23274EN14GLN1

Step 4 – I/O System CheckingExample of I/O devices Inspection

<ZISI::ALL:;

I/O DEVICE WORKING STATE AND SPARE DEVICESYSTEM = BSC31-LAB UNIT = OMUDEVICE STATE SPARE DEVICE DEVICE STATE TAPE STATE TAPE TYPE

FDU-00 WO-BU - -WDU-00 WO-BU - -WDU-01 WO-BU - -LPT-00 BL-SY BSC31-LAB OMU LPT-01 -LPT-01 BL-SY BSC31-LAB OMU LPT-00 -

LPT-02 BL-SY - -LPT-03 BL-SY - -VDU-00 BL-SY - -VDU-01 BL-SY - -VDU-02 BL-SY - -VDU-03 BL-SY - -VDU-04 BL-SY - -VDU-05 BL-SY - -VDU-06 BL-SY - -VDU-07 BL-SY - -VTP-00 BL-SY - -VTP-01 BL-SY - -VTP-02 BL-SY - -VTP-03 BL-SY - -VTP-04 BL-SY - -VTP-05 BL-SY - -VTP-06 BL-SY - -VTP-07 BL-SY - -VTP-08 BL-SY - -VTP-09 BL-SY - -

VPP-00 BL-SY - -VPP-01 BL-SY - -VPP-02 BL-SY - -VPP-03 BL-SY - -VPP-04 BL-SY - -VPP-05 BL-SY - -VPP-06 BL-SY - -VPP-07 BL-SY - -VPP-08 BL-SY - -VPP-09 BL-SY - -VPP-10 BL-SY - -VPP-11 BL-SY - -VPP-12 BL-SY - -VPP-13 BL-SY - -VPP-14 BL-SY - -VPP-95 BL-SY - -VPP-96 BL-SY - -VPP-97 BL-SY - -VPP-98 BL-SY - -VPP-99 BL-SY - -VDS-00 WO-BU - -VDS-01 WO-BU - -VDS-02 WO-BU - -VDS-03 WO-BU - -VDS-04 WO-BU - -VDS-05 WO-BU - -VDS-06 WO-BU - -VDS-07 WO-BU - -VDS-08 WO-BU - -VDS-09 WO-BU - -VDS-10 WO-BU - -VDS-11 WO-BU - -VDS-12 WO-BU - -VDS-13 WO-BU - -VDS-14 WO-BU - -VDS-15 WO-BU - -UMS-00 WO-BU - -UMS-01 WO-BU - -

COMMAND EXECUTED

VTP-10 BL-SY - -VTP-11 BL-SY - -VTP-12 BL-SY - -VTP-13 BL-SY - -VTP-14 BL-SY - -VTP-15 BL-SY - -VTP-16 BL-SY - -VTP-17 BL-SY - -VTP-18 BL-SY - -VTP-19 BL-SY - -VTP-20 BL-SY - -VTP-21 WO-BU - -VTP-22 WO-BU - -VTP-23 BL-SY - -VTP-24 BL-SY - -VTP-25 BL-SY - -VTP-26 BL-SY - -VTP-27 BL-SY - -VTP-28 BL-SY - -VTP-29 BL-SY - -VTP-30 BL-SY - -VTP-31 BL-SY - -VTP-32 BL-SY - -VTP-33 BL-SY - -VTP-34 BL-SY - -VTP-35 BL-SY - -VTP-36 BL-SY - -VTP-37 BL-SY - -VTP-38 BL-SY - -VTP-39 BL-SY - -VTP-40 BL-SY - -VTP-41 BL-SY - -VTP-42 BL-SY - -VTP-43 BL-SY - -VTP-44 BL-SY - -

FDU = Floppy Disk unit

LPT = Line Printer

VDU = Display Unit

WDU = Winchester Disk Unit

CTU = Cartridge Disk Unit

VTP = Virtual Terminal Protocol

VPP = Virtual Printer Protocol

VDS = Virtual Data Storing Device

UMS = USB Mass Storage

•The disk drives should enter the state WO-BU and remain in it.

•The UMS, VDU and LPT units are in WO-ID or BL-SY state, depending on whether the terminal equipment is connected or not. The printer remains in the state WO-BU only for the period during which it is printing.

Page 52: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

52

52 © Nokia Siemens Networks RN23274EN14GLN1

Step 5 – EMB Checking

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

•• Verify the EMB LAN Verify the EMB LAN connection and MAC connection and MAC address of the computer in address of the computer in the LANthe LAN

•• Using EBSTER service Using EBSTER service terminal commandterminal command

EMB Checking

EMB Checking

55

Page 53: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

53

53 © Nokia Siemens Networks RN23274EN14GLN1

Step 5 – EMB CheckingStep-by-step checking the EMB

The EMB LAN switches (ESB24 plug-in units) are configured automatically when they receive an IP address from the dynamic host configuration protocol (DHCP) server.

Step:

1. Go to the service terminal. ZDDS

2. Load EBSTER ZLP:1,EBS

3. Start EBSTER Z1;

4. Send a test message using EMB-0 00:EBS>AT:0x007F,0

5. Send a test message using EMB-1 00:EBS>AT:0x007F,1

6. Check the MAC addresses of all computer units. 00:EBS> A:0x000:0xFFFF

7. Exit EBSTER Z;

8. Unload EBSTER ZL:1;

Page 54: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

54

54 © Nokia Siemens Networks RN23274EN14GLN1

Step 5 – EMB CheckingExample (1/2)

00-MAN>ZLP:1EBS

00-MAN>ZLP:1,EBS00-MAN>1

00-EBS>?

ETHERNET POST OFFICE TESTER

? ..... MENU??..... HELPV ..... VIEW ADDRESSESA ..... STATE / ADDRESS MANAGEMENTS ..... POST OFFICE STATISTICSP ..... POST OFFICE PARAMETERSL ..... VIEW POST OFFICE INTERNAL LOG AND OTHER INFOZ ..... RETURN TO MAIN LEVEL

00-EBS>?A

AT:comp,EMB-side;!* Test the EMB with test message. Send via MB and receive via EMB.!* EMB-side: Specifies that the test message is received via EMB-0 or EMB-1AV:use_emb; !* Switch used media. use_emb: T (use EMB) or F (use MB)A(C):comp:unit,unit[,unit...];!* Ask for the MAC-address of the specified unit(s)in the computers!* MAC-address table!* C = continuous display!* comp = Specifies the computer where the message is sent to!* unit = Specifies the unit whose MAC-address is read from the!* computer's MAC-address table. 0xFFFF means all units.NOTE: if 0x or 0X prefix is missing, the parameter is considered as decimal!

Page 55: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

55

55 © Nokia Siemens Networks RN23274EN14GLN1

Step 5 – EMB CheckingExample (2/2)

00-EBS>AT:0X007F,1Received test messages using EMB-1 from following units:========================================================0000, 0004, 0005, 0031, 0032

00-EBS>AT:0X007F,0Received test messages using EMB-0 from following units:========================================================0000, 0004, 0005, 0031, 0032

0-EBS>A:0X000:0XFFFF

EMB-0 OK, EMB-1 OK

Unit MAC addr 0 Mac addr 1 MB CID EMB0 EMB1 CPU SCD==========================================================================0000 02:00:00:80:00:20 02:00:00:80:00:30 0000 0000 OK OK CP816-A OK0004 02:00:00:80:04:20 02:00:00:80:04:30 0004 0004 OK OK CP816-A OK0005 02:00:00:80:05:20 02:00:00:80:05:30 0005 0005 OK OK CP816-A OK0030 02:00:00:80:30:20 02:00:00:80:30:30 0030 0030 OK OK CP816-A OK0031 02:00:00:80:31:20 02:00:00:80:31:30 0031 0031 OK OK CP816-A OK0032 02:00:00:80:32:20 02:00:00:80:32:30 0032 0032 OK OK CP816-A OK

Page 56: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

56

56 © Nokia Siemens Networks RN23274EN14GLN1

Step 6 – Clock Equipment Check

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

• Switchover of synchronization

unit and the clock and alarm

buffer

• Synchronization unitClock

Equipment Check

Clock Equipment

Check66

Page 57: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

57

57 © Nokia Siemens Networks RN23274EN14GLN1

Step 6 – Clock Equipment CheckChecking the switchover of the clock synchronization

21

Press the front control panel switch

Removing the power supply (PP1/PP2) from the unit

For checking the switchover of the clock system can be done by:

1. Testing the control with the front panel switch (FCTRL), and

2. Removing the power supply connection (PP1/PP2) from the unit.

Do this first to the active and then to the passive unit.

Page 58: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

58

58 © Nokia Siemens Networks RN23274EN14GLN1

Step 6 – Clock Equipment CheckChecking the Synchronization unit

• CL3TGs have four synchronisation inputs. The clock synchronisation unit switches over to use the input 2M1 first, then 2M2, 2M3, and 2M4 respectively, within the time TR.

• The default values of ET16s are 368, 640, 256, and 524• The default time value is 10 minutes.• On both CL3TG plug-in units, the indicator lamp for the synchronisation input in

question is lit.• Checking the synchronization unit can be done by doing:• Simulating the synchronization input:

– Make a loop-back: 1 4; 2 5– Connect the loop-backs to the ETs– Set all synchronisation inputs to the state CONNECTED.– Open new synchronisation input (DRC). ZDRC:2M2;– Delete the synchronisation inputs (DRD). ZDRD:2M2;– The synchronisation input 2M1 should be in the state CONNECTED and in use (USED

INPUT). Check this with the DRI command: ZDRI;– The other synchronisation inputs should also be in the CONNECTED state.

• Checking the synchronisation unit with a changeover– Check the indicator lamp.– Make a changeover to the backup connection (DRS, DRI).– Disconnect the second loop-back.– Make a changeover to internal oscillator (DRI).– Make a synchronisation with external clock.

When disconnecting the first (and the other) loop-back, the following messages are displayed on the alarm printer:

2641 FAILURE IN SYNCHRONISATION SIGNAL

0630 SYNCHRONISATION SIGNAL CHANGED

Page 59: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

59

59 © Nokia Siemens Networks RN23274EN14GLN1

Step 7 – HW Configuration Checking

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

• Compare HW Configuration with

Hardware list in the site specific

document

• Print the HW configuration can

be done using the command:

ZWTI:J;ZWTI:J;

ZWTI:C;ZWTI:C;

ZWTI:U;ZWTI:U;

ZWTI:P;ZWTI:P;

• Or, if using the printer, can use

the command:

ZWTI::,LPT0;

Hardware Configuration

Checking

Hardware Configuration

Checking77

Page 60: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

60

60 © Nokia Siemens Networks RN23274EN14GLN1

Step 8 – Maintenance System Checking

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

• Testing the alarm system

- Wired alarms

- External alarms

- Alarm output

• Testing the recovery from power breaks

- From power break in the system

- From power break in the PDFU

- Fuse fault in the the supply cable

• Plug in Unit tests:- State transitions

- Unit Diagnostics

- Spare Unit

Maintenance System

Checking

Maintenance System

Checking88

Reference: Commissioning BSC3i (DN02199145, issue 6-1) section 9 on Nokia BSC3i, Rel. S13, Site Documentation, v.3

Page 61: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

61

61 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch Checking

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

• Local reset and the Hotswapbutton

• Built-in self test

ESB Switch Checking

ESB Switch Checking

99

Reference: Commissioning BSC3i (DN02199145, issue 6-1) on Nokia BSC3i, Rel. S13, Site Documentation, v.3

Page 62: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

62

62 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingLocal reset and the Hotswap button in the ESB switch

• The ESB switches are located in the MCMU and LANU units.

• The ESB switch can be disconnected without switching the power off from other PIUs in the MCMU or LANU.

The tests are:

1. Local reset and the Hotswap button in the ESB switch

– Check the Operation Indicator.▪ Green indicates that the unit is operational.

▪ Red is lit during the power up and in fault conditions.

▪ Blinking, it means that no image software is loaded.

▪ No light, it means that the power is off.

– Perform the local restart (press reset button) and the hotswap.

– Repeat for each ESB

ESB24

The ESB switch gets power from the MCMU or LANU unit. The ESB switch can be disconnected without switching the power off from other PIUs in the MCMU or LANU.

Steps

Expand/collapse all

Check the Operation Indicator.

The Operation Indicator (OPR) is a single two-colour led (green/red) in the front panel of the ESB switch.

Explanations on the indicator light:

Green indicates that the unit is operational.

Red is lit during the power up and in fault conditions.

If the light is blinking, it means that no image software is loaded.

If there is no light, it means that the power is off.

Green is the default colour for the OPR.

Perform the local restart and the hotswap.

To perform the hotswap, press the Hotswap reset button (RST) twice within two seconds before removing the card. The power is turned off for 20 seconds, during which the card can be removed safely.

Set the ESB switch.

Set the ESB switch back to its position. The OPR should be first red and after a while change to green.

Repeat steps 1 to 3 with every ESB switch.

Page 63: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

63

63 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingChecking the built-in self test of the ESB24-D switch

2. Checking the built-in self test of the ESB24-D switch

• The ESB26 switch uses the Command Line Interface (CLI) for communication

• Configure the terminal (PC)

• Open the ESB26 switch service terminal sessionUser Access VerificationPassword:SWU-0>

• Check the built-in self test : SWU-0>enableSWU-0#self-test

• Check the boot and software version.SWU-0#reload

• Repeat with every ESB switch.

X on/ X offFlow control

NoneParity

1Stop bits

8Data bits

9600Baud rate

nsn-switch

ESB24

Page 64: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

64

64 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingExample of checking the built-in self test of the ESB24-D switch

User Access Verification

Password:

SWU-0>

SWU-0>enable

SWU-0#self-test

CPU Core Test :

CPU Validation - Passed

CPU Notify RAM Test :

RAM Validation - Passed

CPU Interface Test :

UART Existence - Passed

Testing Switch Core :

Crossbar Existence - Passed

Data Buffer Test :

Boot Loader Image Validity - Passed

Application Image Validity - Passed

Startup Configuration Validity - Passed

Script File System Validity - Passed

PROM Device Access Validity - Passed

On-board Power Test :

On-board Power PHY - Passed

On-board Power CPU - Passed

On-board Power OC - Passed

Temperature Test :

Temperature - Passed

SWU-0#reload

Save current configuration and reboot the Switch ? [y/n] : y

Building the configuration ...

Rebooting ...

Press any key to stop auto-boot...

0

Verifying validity of primary application.....OK

Start primary application...

BUILT-IN SELF TEST

------------------

CPU Core Test : Passed

CPU Notify RAM Test : Passed

CPU Interface Test : Passed

Testing Switch Core : Passed

Data Buffer Test : Passed

On-board Power Test : Passed

//////////////////////////////////////////////////////////////// ///////

// //

// N O K I A //

// //

// //

// Switch model : NOKIA ESB26 //

// SW version : 3.13.1.4 created Mar 7 2005 - 13:30:39 //

// //

////////////////////////////////////////////////////////////////////////

User Access Verification

Password:

nsn-switch

Page 65: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

65

65 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingFlexi BSC LAN topology

• The Flexi BSC (BSC3i 3000) contains BCSUs 0 - 6 and SWUs 0 - 5.

• SWU-0 & SWU-1 are used for CPULAN

• SWU-2,3,4 and 5 are used for PCULAN

• SWU-60 & 61 are used for EMB

SWU = Switching unit is the generic name for the L2 Ethernet switch plug-in unit integrated into the BSC3i

LANU =The LAN Switching Unit hosts the SWUs for CPULANs and

PCULAN = Packet Control unit LAN

CPULAN = Computer Processor Unit LAN

CPRJ45-A = LAN Connector Panel for RJ45 connectors.

LDI = Lan Device Integration

VRRP = Virtual Router Redundance Protocol

Page 66: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

66

66 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingFlexi BSC CPULAN topology, CNW and EMB

LAN Topology T5 (Flexi BSC First Delivery)

Page 67: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

67

67 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingFlexi BSC PCULAN topology (3/4)

LAN Topology T5 (Flexi BSC First Delivery)

for SWU-2 & SWU-3

Page 68: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

68

68 © Nokia Siemens Networks RN23274EN14GLN1

Step 9 – ESB Switch CheckingFlexi BSC PCULAN topology (4/4)

LAN Topology T5 (Flexi BSC First Delivery)

for SWU-4 & SWU-5

Page 69: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

69

69 © Nokia Siemens Networks RN23274EN14GLN1

Step 10 – SW version Verifying

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011 •• Printout all SW packages:Printout all SW packages:

ZWQO;

•• Verify all SW packagesVerify all SW packages

ZWQB;

•• Or, print to the printer using:Or, print to the printer using:

ZWQO::,LPT0;

ZWQB::,LPT0;

SW version verifying

SW version verifying

1010

Page 70: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

70

70 © Nokia Siemens Networks RN23274EN14GLN1

Step 10 – SW version Verifyingexample

MAIN LEVEL COMMAND <___>< ZWQO:CR;

LOADING PROGRAM VERSION 14.13-0

PACKAGES CREATED IN OMU:

SW-PACKAGE STATUS DIRECTORY ENVIRONMENT DEF ACTPACKAGE-ID (REP-ID) DELIVERY

CD-ID

FB090623 FB FB090623 SE 1.25-0 - Y SE 1.25-0 1 CIDE00SX 1.13-0

SEPI0100

SEPI0200 BU FB090617 SE 1.25-0 Y Y SE 1.25-0 2 CIDE00SX 1.13-0

SEPI0200

SETEST NW ASE_1_25_0 SE 1.25-0 - Y SE 1.25-0 1 CIDE00SX 1.13-0

SEPI0100

S14REL UT ASE_1_25_0 SE 1.25-0 - N SE 1.25-0 CIDE00SX 1.13-0

FB090506 UT FB090506 SE 1.25-0 - Y SE 1.25-0 1 CIDE00SX 1.13-0

SEPI0100

FBFIRST UT FB_050509 SE 1.25-0 - Y SE 1.25-0 CIDE00SX 1.13-0

FB090617 UT FB090617 SE 1.25-0 - N SE 1.25-0 1 CIDE00SX 1.13-0

SEPI0100

COMMAND EXECUTED

Page 71: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

71

71 © Nokia Siemens Networks RN23274EN14GLN1

Step 11 – Copying additional SW and Setting Time Zone

Checking the HWChecking

the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-

up

Monitoring the Start-

up

Maintenance System Checking

Maintenance System Checking

ESB Switch

Checking

ESB Switch

Checking

SW version verifyingSW version

verifying

Copying additional SW and

setting time zone

Copying additional SW and

setting time zone

I/O System CheckingI/O System

Checking

EMB CheckingEMB

Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration Checking

Hardware Configuration Checking

1 2 3 4

8 7 65

9 1011

• Insert the Customer Specific disk to the BSC3i magneto-optical drive

• Copy the diskette (IWY, IBC).

• Install the Change Deliveries.

• Set the time zone (DCE).

• Change the clock to summer time/standard time (DCT).

• Restart the system (USS)

Copying additional SW

and setting time zone

Copying additional SW

and setting time zone 1111

Page 72: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

72

72 © Nokia Siemens Networks RN23274EN14GLN1

Fault Handling in Flexi BSC Commissioning

Page 73: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

73

73 © Nokia Siemens Networks RN23274EN14GLN1

Objectives

Handle the basic faults encountered during BSC commissioning procedureDisplay the alarm printouts, run diagnostics and obtain reports on request from a supporting BSC expert.

Instructional Notes

The objectives in this module support the actual activity of fault handling during commissioning the BSC. This module has a significant practical element.

Page 74: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

74

74 © Nokia Siemens Networks RN23274EN14GLN1

BSC3i Commissioning Procedure

Checking the HW

Checking the HW

Opening the first MML Session

Opening the first MML Session

Monitoring the Start-upMonitoring the Start-up

Maintenance System

Checking

Maintenance System

Checking

ESB Switch Checking

ESB Switch Checking

SW version verifying

SW version verifying

Copying additional SW

and setting time zone

Copying additional SW

and setting time zone

I/O System Checking

I/O System Checking

EMB Checking

EMB Checking

Clock Equipment

Check

Clock Equipment

Check

Hardware Configuration

Checking

Hardware Configuration

Checking

New New procedure in procedure in S.12S.12

11 22 33 44

88 77 66 55

99 1010 1111

Page 75: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

75

75 © Nokia Siemens Networks RN23274EN14GLN1

BSC Fault Handling

?

Question: When carrying out the commissioning procedures what types of

faults might you encounter?

Page 76: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

76

76 © Nokia Siemens Networks RN23274EN14GLN1

Typical BSC Commissioning Faults

Incorrect cabling of BSC

Faulty Plug in unit

Peripherals not connected correctly

Software versions not correct

Power failure

Software load failure of CPU

Incorrect unit states

Wrong EPROM versions

PIU links not set correctly

PIU inserted in the wrong place

Faulty backplane or connector(s)

Damage from ESD

Page 77: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

77

77 © Nokia Siemens Networks RN23274EN14GLN1

Identifying BSC Commissioning Faults

??

Question: How will you know that a fault exists during the commissioning

process?

Page 78: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

78

78 © Nokia Siemens Networks RN23274EN14GLN1

BSC Fault Handling Diagnostic Tools

!• Plug in Unit LEDs

• Man Machine Interface (MMI)

• Service Terminal Emulator (RCBUGG)

• Man Machine Language (MML)

• Alarm printouts

• Run diagnostics

Page 79: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

79

79 © Nokia Siemens Networks RN23274EN14GLN1

Processor CP816-A LED Diagnostics

WO green in working state

RUN green operating normally

P0 (ET0) yellow LAN0 is active

P1 (ET1) yellow LAN1 is active

TE yellow in test state (TE).

LE red Software Control LED.

P2 (ET2) yellow LAN2 is active

P3 (ET3) yellow LAN3 is active

Page 80: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

80

80 © Nokia Siemens Networks RN23274EN14GLN1

BSC Fault Handling Diagnostic Tools

• LEDs

• MMI Information

• Check Alarm Printouts

• Run Diagnostics

Page 81: Flexi BSC Commissioning

RN23274EN14GLN1

Flexi BSC Commissioning

81

81 © Nokia Siemens Networks RN23274EN14GLN1

BSC Fault Handling Practical Exercise