8/10/2019 Configuration & Commissioning Alarm BSC Box
1/24
Configuration & commissioningAlarm BSC box
WAGO alarm BSC box with double Ethernet ( X1 & X2 )
8/10/2019 Configuration & Commissioning Alarm BSC Box
2/24
To commissioned any version from alarm BSC box ,must know below diagram well
OMC BSC Evo Alarm BSC box
TELECOM Switch Router
Workas
Workas
Workas
8/10/2019 Configuration & Commissioning Alarm BSC Box
3/24
1. Connect to BSC to get some IPs that willuse in commissioned alarm BOX
A) Connect to BSC as below snapshots
- Put IPs Local area connection as below
8/10/2019 Configuration & Commissioning Alarm BSC Box
4/24
- Then open Windows 9130 BSC terminal and Put below IP address
OK to be connect on BSC
8/10/2019 Configuration & Commissioning Alarm BSC Box
5/24
- To be master on BSC take any action locally press F6 and F5 to view Full report
parallel as below
8/10/2019 Configuration & Commissioning Alarm BSC Box
6/24
B) Now after connect , needed to get BSC IP address that OMC can see BSC from it and r
BSC IP addressas below
-- Commands >> BSS Operations >> Display IP Parameters
8/10/2019 Configuration & Commissioning Alarm BSC Box
7/24
-- Press OK
8/10/2019 Configuration & Commissioning Alarm BSC Box
8/24
-- Double click or press ENTER on DIS IP PARAMETERS to view this reports
8/10/2019 Configuration & Commissioning Alarm BSC Box
9/24
-- appear window with multi. Tabs , select IP Parameters Page 1 Ta
8/10/2019 Configuration & Commissioning Alarm BSC Box
10/24
-- from this Tab , we can get real BSC IP addressas 10.58.69
8/10/2019 Configuration & Commissioning Alarm BSC Box
11/24
-- To get BSC IP address that OMC can see BSC from it , follow below slides
Commands >> BSS Operations >> Display BSC Peer Entities
8/10/2019 Configuration & Commissioning Alarm BSC Box
12/24
-- Double click or press ENTER on DIS IP ENTITIES to view this rep
8/10/2019 Configuration & Commissioning Alarm BSC Box
13/24
-- from this window , we can get BSC IP address that OMC can see BSC from it as b
Display BSC Peer Entities >> Address -2 >> BSC NTP IP Address as 10.57.216.12
8/10/2019 Configuration & Commissioning Alarm BSC Box
14/24
-- Now , we get below IPs from BSC that will use in commission alarm BSC box
1) BSC IP address that OMC can see BSC from it as 10.57.216.12
2) Real BSC IP address as 10.58.69.49
Note : OMC can see BSC from two IP ( 1 0r 2 ) depend on early creation and in this case was (
8/10/2019 Configuration & Commissioning Alarm BSC Box
15/24
2. Commissioned Alarm BSC box
A) Connect to Alarm BSC box via Ethernet cable on X1
-- Put Local area connection IPs as below
8/10/2019 Configuration & Commissioning Alarm BSC Box
16/24
-- in any URL page put 192.168.1.1 to open Main page for WAGO
8/10/2019 Configuration & Commissioning Alarm BSC Box
17/24
-- Select TCP/IP tab from left corner , needed username & Password put it as below
Username : adminPassword : wago
8/10/2019 Configuration & Commissioning Alarm BSC Box
18/24
-- in TCP/IP tab
** Put IP address as 10.58.69.54 that mean +5 from real BSC IP address as BSC keep this IPfor Alarm BOX
** Put Gateway as 10.58.69.51 that mean +2 from real BSC IP address as BSC keep this IP f
DCN IP
Then SUBMIT to save changes
8/10/2019 Configuration & Commissioning Alarm BSC Box
19/24
-- Then select Ports tab from left corner to configured it , needed username & Passwordit as below
Username : adminPassword : wago
8/10/2019 Configuration & Commissioning Alarm BSC Box
20/24
-- in Ports tab
** Make check / uncheck as below then SUBMIT to save changes
8/10/2019 Configuration & Commissioning Alarm BSC Box
21/24
-- select SNMP tab from left corner
** Put Trap receiver 1 as 10.57.216.12 this IP that OMC from it can see BSC
Then SUBMIT to save changes
8/10/2019 Configuration & Commissioning Alarm BSC Box
22/24
-- Select Clock tab from left corner
** adjust Time & date as below
Then SUBMIT to save changes
8/10/2019 Configuration & Commissioning Alarm BSC Box
23/24
-- after that Alarm BSC box configured well and its IP changed to be 10.58.69.54 so if y
want to connect it again
** Local area connection must be
** Put in any URL 10.58.69.54 not 192.168.1.1
8/10/2019 Configuration & Commissioning Alarm BSC Box
24/24
With my best wishe
Eng. Ahmed MagdI AhmedMobiserve Egypt / Menya office