Upload
fly4phun
View
153
Download
3
Embed Size (px)
DESCRIPTION
Installation instructions for NetApp FAS32xx.
Citation preview
• Enter the values from the configuration worksheet when prompted by setup script.
Complete initial network configuration4
51 2 3 4
• “Getting Started” and training videos: https://communities.netapp.com/community/netapp_university/getting_started
• NetApp solutions: http://www.netapp.com/us/solutions/
• Technical reports: http://www.netapp.com/us/library/technical-reports.html
• General information: http://www.netapp.com/us/library/
LEARN MORE
• Site Requirements Guide: https://library.netapp.com/ecm/ecm_get_file/ECMP1112530
• Controller and configuration examples: https://library.netapp.com/ecm/ecm_get_file/ECMP1124782
• NetApp System Installation Workbook: https://fieldportal.netapp.com/search/?searchTerm=Installation+Workbook#
• OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
• Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
• Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
Site Requirements Guide
License site for your system
NetApp System Installation Workbook
Configuration Examples for FAS32xx systems
Data ONTAP library • Storage Management Guide• Logical Storage Management Guide• File Access & Protocols Management Guide• Data Protection Guide
OnCommand System Manager documentation set
HELPFUL LINKSVisit the NetApp web site for more information.
HELPFUL LINKSVisit the NetApp web site for more information.
Complete System Setup4
1 2 3 4 5
Complete Configuration5
• Create an account.• Register your system.• Get your license keys.
Register at support.netapp.com1
• Run Configuration Checker from support.netapp.com
Validate storage configuration2
• Provision storage.• Configure protocols and data protection.• Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager3
Cable serialconsole
2
Power on your system 3
Complete configuration worksheet• Complete configuration worksheet from
NetApp System Installation Workbook
1System Installation Workbook
Power on disk shelvesALL power supplies MUST be powered on.
1 Power on controllerALL power supplies MUST be powered on.
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
A
B
1
2
LNK LNKIOM6
IOM6
LNK LNKIOM6
IOM6
DC AC
x22
DC AC
x22
A
B
1
2
DC AC
x22
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Serial console connectionConnection to D89 serial console port
or USB-to-D89 converter to laptop
Rack spaceThe FAS32xx system requires 3U or 6U of rack space as well
as power and network connectivity
ScrewdriverFor securing hardware
into your racks
Prepare for installation14 51 2 3
You need to provide:2
Additional network cablesFor connecting your storage
to your network switches.
Installation and Setup Instructions32xx Systems
Network cables Power cables
ACCESSORY TRAY
Storage cables HA cables
Find in the box:1
HELPFUL LINKS ON PAGE 4
Serial cable
2 1 0 - 0 6 1 0 3 + A 02 1 0 - 0 6 1 0 3 + A 0
4 51 2 3
Single chassis HA with either DS424x or DS2246 disk shelves
Dual chassis HA with DS424x disk shelves
Cable storage (Choose option A or B below) 3
B
A
HELPFUL LINKS ON PAGE 4 For additional configurations, see HELPFUL LINKS.
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
Network cables
2
1
3
4
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
X1037A
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
Daisy chain SAS ports
Cable first SAS ports
Cable last SAS ports
Cable ACP connections
Network cables
2
1
3
4
Daisy chain SAS ports
Cable first SAS ports
Cable last SAS ports
Cable ACP connections1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
Storage cables
Storage cables
X1037A
X1037A
X1037A
ABCD ABCD
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
HA cables HA cables
4 51 2 3FRONT VIEW OF SYSTEM
BACK VIEW OF SYSTEM
ALL power cords MUST be used for all units.
Install hardware2
LIFTING HAZARDCAUTION
37 kg (82 lbs.)
• Rack the system. - Rail kit: follow instructions in rail kit. - System cabinet: install in system cabinet.
• Place the bezel over the front of the system.
Install system1
Cable controller to switches (Choose option A or B below)
7-Mode, HA
2
HELPFUL LINKS ON PAGE 4
Network cables Network cables
DO NOT power on system at this point.
3 Connect power cordsPower cords
Attach cable management arm
Cable c0a to c0a ports and c0b to c0b ports on both controllers.
Cable wrench ports to the Management switches.
Connect e1a and e2a to Cluster switches.
OPTIONAL 2-POST MID-MOUNT BRACKETS
Use retaining clips Use retaining clips
BezelAttention LED
Power LED Controller A and B status LED
FAS3270FAS3270
• Cable both power supplies for each chassis.
See your network administrator for help connecting to your switch.
4
1
2
3
Attach cable management arm
Cable c0a to c0a ports and c0b to c0b ports on both controllers.
Cable wrench ports to the switch.
Connect e0a ports to the switch.
4
1
2
3
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Slots for NIC and storage cards
LNK
0c
0d e0b
e0a
c0b
c0a
HA interconnect ports (c0a, c0b)
Fiber channel ports (0c, 0d)
SAS ports (2)
0a 0bLNK LNK
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Console port (Setting: 9600 N-8-1)
Gigabit Ethernet ports (2)
Remote/Node Management port(wrench icon)
PCM Attention LED
NVMEM LED
ACP port(locked wrench icon)
1
2
A Cluster-ModeB
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6AC
TB
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ABCD
ABCD
ABCD
ABCD
1
1
3
1
1
2 3 4
4
2
4 51 2 3
Single chassis HA with either DS424x or DS2246 disk shelves
Dual chassis HA with DS424x disk shelves
Cable storage (Choose option A or B below) 3
B
A
HELPFUL LINKS ON PAGE 4 For additional configurations, see HELPFUL LINKS.
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
N
31
42
Disconnect allsupply power forcomplete isolation .
N
31
42
Disconnectallsupplypowerforcompleteisolation .
IOM3
IOM3
LINK
LINK
IOM3
IOM3
LINK
LINK
Network cables
2
1
3
4
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
X1037A
ACT /L NKB1 0=O FF
100 =GRN1000= ORG
Intel* PRO
AC T/LNKA
Daisy chain SAS ports
Cable first SAS ports
Cable last SAS ports
Cable ACP connections
Network cables
2
1
3
4
Daisy chain SAS ports
Cable first SAS ports
Cable last SAS ports
Cable ACP connections1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
1
2
AC AC
IOM3
IOM3
LINK
LINK IOM3
IOM3
LINK
LINK
Storage cables
Storage cables
X1037A
X1037A
X1037A
ABCD ABCD
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
HA cables HA cables
4 51 2 3FRONT VIEW OF SYSTEM
BACK VIEW OF SYSTEM
ALL power cords MUST be used for all units.
Install hardware2
LIFTING HAZARDCAUTION
37 kg (82 lbs.)
• Rack the system. - Rail kit: follow instructions in rail kit. - System cabinet: install in system cabinet.
• Place the bezel over the front of the system.
Install system1
Cable controller to switches (Choose option A or B below)
7-Mode, HA
2
HELPFUL LINKS ON PAGE 4
Network cables Network cables
DO NOT power on system at this point.
3 Connect power cordsPower cords
Attach cable management arm
Cable c0a to c0a ports and c0b to c0b ports on both controllers.
Cable wrench ports to the Management switches.
Connect e1a and e2a to Cluster switches.
OPTIONAL 2-POST MID-MOUNT BRACKETS
Use retaining clips Use retaining clips
BezelAttention LED
Power LED Controller A and B status LED
FAS3270FAS3270
• Cable both power supplies for each chassis.
See your network administrator for help connecting to your switch.
4
1
2
3
Attach cable management arm
Cable c0a to c0a ports and c0b to c0b ports on both controllers.
Cable wrench ports to the switch.
Connect e0a ports to the switch.
4
1
2
3
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Slots for NIC and storage cards
LNK
0c
0d e0b
e0a
c0b
c0a
HA interconnect ports (c0a, c0b)
Fiber channel ports (0c, 0d)
SAS ports (2)
0a 0bLNK LNK
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Console port (Setting: 9600 N-8-1)
Gigabit Ethernet ports (2)
Remote/Node Management port(wrench icon)
PCM Attention LED
NVMEM LED
ACP port(locked wrench icon)
1
2
A Cluster-ModeB
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
2 4 6 8
1 3 5 7
10 12 14 16
9 11 13 15
12
11
14
13
16
15
6
5
8
7
10
9
2
1
4
31000/100/10MLNK /
1000/100/10MLNK /
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
5 6 7 81 2 3 4 13 14 15 169 10 11 12
12
LNK /SPD LNK /SPD
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ACT
B
LNK
B
ACT
A
LNK
A
X1117A
ABCD
ABCD
ABCD
ABCD
1
1
3
1
1
2 3 4
4
2
• Enter the values from the configuration worksheet when prompted by setup script.
Complete initial network configuration4
51 2 3 4
• “Getting Started” and training videos: https://communities.netapp.com/community/netapp_university/getting_started
• NetApp solutions: http://www.netapp.com/us/solutions/
• Technical reports: http://www.netapp.com/us/library/technical-reports.html
• General information: http://www.netapp.com/us/library/
LEARN MORE
• Site Requirements Guide: https://library.netapp.com/ecm/ecm_get_file/ECMP1112530
• Controller and configuration examples: https://library.netapp.com/ecm/ecm_get_file/ECMP1124782
• NetApp System Installation Workbook: https://fieldportal.netapp.com/search/?searchTerm=Installation+Workbook#
• OnCommand System Manager documentation set: http://support.netapp.com/documentation/productlibrary/index.html?productID=61372
• Data ONTAP 8 library: http://support.netapp.com/documentation/productlibrary/index.html?productID=30092
• Licenses: http://support.netapp.com/eservice/agree.do?moduleName=PROTOCOL
Site Requirements Guide
License site for your system
NetApp System Installation Workbook
Configuration Examples for FAS32xx systems
Data ONTAP library • Storage Management Guide• Logical Storage Management Guide• File Access & Protocols Management Guide• Data Protection Guide
OnCommand System Manager documentation set
HELPFUL LINKSVisit the NetApp web site for more information.
HELPFUL LINKSVisit the NetApp web site for more information.
Complete System Setup4
1 2 3 4 5
Complete Configuration5
• Create an account.• Register your system.• Get your license keys.
Register at support.netapp.com1
• Run Configuration Checker from support.netapp.com
Validate storage configuration2
• Provision storage.• Configure protocols and data protection.• Set up Service Processor and Remote Support Agent.
Download OnCommand System Manager3
Cable serialconsole
2
Power on your system 3
Complete configuration worksheet• Complete configuration worksheet from
NetApp System Installation Workbook
1System Installation Workbook
Power on disk shelvesALL power supplies MUST be powered on.
1 Power on controllerALL power supplies MUST be powered on.
2
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
A
B
1
2
LNK LNKIOM6
IOM6
LNK LNKIOM6
IOM6
DC AC
x22
DC AC
x22
A
B
1
2
DC AC
x22
0a 0bLNK LNK
0c
0d e0b
e0a
c0b
c0a1
2
3
4
5
6
Serial console connectionConnection to D89 serial console port
or USB-to-D89 converter to laptop
Rack spaceThe FAS32xx system requires 3U or 6U of rack space as well
as power and network connectivity
ScrewdriverFor securing hardware
into your racks
Prepare for installation14 51 2 3
You need to provide:2
Additional network cablesFor connecting your storage
to your network switches.
Installation and Setup Instructions32xx Systems
Network cables Power cables
ACCESSORY TRAY
Storage cables HA cables
Find in the box:1
HELPFUL LINKS ON PAGE 4
Serial cable
2 1 0 - 0 6 1 0 3 + A 02 1 0 - 0 6 1 0 3 + A 0