1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H+, D+, 4He2+ from 5 to 6,5 MeV/nucleon)

Current status: modernized, still in use.

1972 – 1973 – comissioning of the HVEC FN Tandem accelerator

Current status: modernized, still in use.

Page 3: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

Maximum terminal voltage (9 MV, upgraded from 7 MV)

Accelerated ion species: from protons to gold.

Tipical analized beam currents: tens to hundreds of nA.

Page 4: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in
Page 5: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

NEC SNICS II type

NEC SNICS II type for AMS

Duoplasmatron with Li charge exchange

Page 6: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

Milisecond pulsing system

“Fast” pulsing system (nanoseconds) ◦ Chopper frequencies:

5 MHz and subdivisions

◦ Buncher: packing 25%, pulse duration 1-3 ns

“Slow” pulsing

system (>miliseconds) ◦ home made ◦ Chopper system, two

plates at high voltage

Page 7: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

The old charging system was replaced with a Pelletron chain system ◦ improved charging efficiency

◦ major increase in reliability

◦ maintenance of the Pelletron is done 100% by the TANDEM technicians

New set of accelerator tubes ◦ Titanium electrodes, spiral fields

◦ increased reliability and lifetime

Improvement of ion optics inside the accelerator ◦ transmission between 90-95% at optimum

terminal voltage

Page 8: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in
Page 9: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

Nuclear structure

IBA

Reaction meachanisms

Multipurpose

AMS

Fusion evaporation product spectrometer

Page 10: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

7-8 55% HPGe detectors 5-8 LaBr3:Ce detectors

Page 11: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

Analog aquisition system

XIA DGF system

Page 12: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

500 1000 1500 2000

100

300

500

700

100

300

500

700

E [keV]

FWHM/centroid

= 3.5%

FWHM/

centroid

= 3.3%

2.6%2.1%

1.8%

2.5%

2.0%1.7%

source at rest in lab frame

source moving with =10% along z-axis, det =168•

Best energy resolution achievable with scintillators

Timing comparable with BaF2 : 100-300 ps depending on crystal

size

3 2”x2” , 3 1.5”x1.5”, 2 conical shaped 1”x1.5”x1.5” (total 8

LaBr3:Ce detectors )

Might be used to measure lifetimes in the 50ps – few ns range

Page 13: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

February 15th to July 1st, 2010;

126 days meaning 3024 hours available for scheduled experiments

From 3024 hours scheduled for the experiments we had 2887 hours of analyzed beam

49 days meaning 1176 hours, were used by foreign research groups

Page 14: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

Array of 25 HPGe 55% detectors

with BGO anti-Compton shields

Mechanical project of R. Dima (IFIN-HH)

Absolute detection efficiency ~ 1%

Expected commissioning : mid 2011

Page 15: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

One 3 MV TANDEM accelerator and associated equipment for ion beam analysis (from HVEC)

One 1 MV TANDEM accelerator and associated equipment dedicated for AMS detection technique of 14C (from HVEC)

One ACSI TR19 cyclotron for research and production of medical radioisotopes

Page 16: Dr. Dan Gabriel Ghiţă IFIN-HH...1956 – 1957 – comissioning of the U120 cyclotron accelerator (2H +, D , 4He2+ from 5 to 6,5 MeV/nucleon) Current status: modernized, still in

The old equipment on the accelerators was replaced with new, more reliable one.

New associated detection and aquisition systems were build.

New accelerators dedicated to applied research are on the way.