Upload
lamnhu
View
215
Download
2
Embed Size (px)
Citation preview
TCS- BOB Confidential 2
Revision History
Date Version Author Comments Date of review
29-Jun-13 1.0 Manish Chandnani
BOB KIOSK Installation Manual for installation of Legend and Cogent CSD 200 drivers
01-Aug-13
1.1 Amol Bidrolkar
BOB KIOSK Installation Manual for installation of Legend and Cogent CSD 200 drivers with Precision And Inspira’s SDK
29-Oct-13 1.2 Amol Bidrolkar BOB KIOSK Installation Manual for installation of Legend and Cogent CSD 200 drivers with Precision SDK
01-Aug-14
1.3 Amol Bidrolkar BOB KIOSK Installation Manual for installation of Legend and Cogent CSD 200 drivers with Precision SDK for NFIQ version 2.3.6 and with JDK 1.7 update 7
Distribution List
S. No Name Role
Approvers List
Approved By Name Signature Organization Date of review
Project Manager Manish Chandnani TCS 01-Aug-2014
Contacts
For questions or comments about this document’s technical content or to request changes to the document, contact:
Contact Details Phone Organization
Extension-no-1 022-66984959 TCS
Extension-no-2 022-66984956 TCS
Extension-no-3 022-66984957 TCS
TCS- BOB Confidential 3
Preface This is the help guide for installation of fingerprint devices i.e. Cogent CSD 200 and Legend fingerprint device of Precision API for BOB Kiosk project
Purpose This document gives the flow of the installation of Cogent CSD 200 and Legend fingerprint device for version 2.3.6 with NFIQ. The package installation consists of new version of Precision API version 2.3.6 with Java jdk 1.7 update 7, Vc++ redistributable 2008, Legend drivers, Cogent CSD 200 drivers, browser setting vbs file, java policy, certificate and URL in favorites of IE for KIOSK login. This is single click installation package used for ease of installation.
Target Audience The primary audiences for this document are:
CSC Technical Support Team VLE’s
TCS- BOB Confidential 4
Contents BANK OF BARODA KIOSK……………………………………………………………………………………….............1
FINGERPRINT DEVICE INSTALLATION PROCEDURE…………………………………………………………….6
1. JAVA SET UP………………………………………………………………………………………………………….9
2. VC++ INSTALLATION………………………………………………………………………………………………11
3. BROWSER SETTING………………………………………………………………………………………………...12
4. INSTALL PRECISION’S SDK………………………..……………………………………………………………...13
5. INSTALL COGENT AND LEGEND DEVICE DRIVERS……………………..…………………………………..14
6. TEST DEVICE…………………………………………………………………………………………………………18
TCS- BOB Confidential 5
Fingerprint Device Installation Procedure
If you are using Windows 7 you need to do the following setting.
Go to Control Panel User Accounts and Family Safety User Accounts
And then Click on “Change User Account Control Settings” and do the following setting
Drag the horizontal bar to “Never Notify” and Click on ‘OK” as shown below
NOTE: If your Operating System is Windows XP you are not required to do above setting and if your
Antivirus is “ON” then kindly Turn off until your installation gets finished
TCS- BOB Confidential 6
Copy “BOBKiosk_v2.3.6” folder from given “CD” or FTP Link “to ‘C: \’ (C-Drive).
Ensure you have logged in with the user having administrative rights.
Ensure Internet is connected before proceeding.
In “BOBKiosk_v2.3.6” folder, Right click on ‘BOBKIOSK.bat’ file and click on ‘Run as
administrator’ as shown below.
If the window is coming asking “Do you want to allow the following program to do
changes to your computer” – Click on Yes.
If your operating system is Windows XP then you double Click “‘BOBKIOSK.bat’” to run
the batch file.
TCS- BOB Confidential 7
Following prompt will be displayed and Press any key to start the installation process.
If you are getting below message
“Administrative permissions required. Detecting Administrative Permissions....
Insufficient Administrator Previledges....Please login in as Administrator.... Exiting the setup....
Press any key to continue . . .”
It means you don’t have admin rights on machine or you have directly double click on batch program.
Please ensure you have admin rights on machine or you right lick on batch program and select option
“Run as Administrator”
TCS- BOB Confidential 8
After pressing any key for installation the following prompt will be displayed to uninstall previous
version of BOBBMA Client API , Validity Sensor legend drivers, java jdk and jre. And if none of
the instance of the software is available then it will display “No instance available”.
TCS- BOB Confidential 9
1. Java Setup
After above step, Java SDK 1.7 update 7 will start installation automatically and follow the steps
shown below to configure and setup java.
Java (JDK and JRE) installation process begins.
a) Click on “Next”
b) Note: Click on small drop down beside “Development Tools” and select “This feature, and
all sub features, will be installed on local hard drive”
c) Similarly Click on small drop down beside “Source Code” and select “This feature, and all sub
features, will be installed on local hard drive”.
d) Similarly Click on small drop down beside “Public jre” and select “This feature, and all sub
features, will be installed on local hard drive”.
e)
TCS- BOB Confidential 10
Ensure you are also installing Java Run Time Environment…..
After installing JRE you will get a Successful message. Click on “Close”
NOTE: Ensure that java Policy is copied in java installation folder in your system as shown in
screenshot below 3 File(s) copied.
TCS- BOB Confidential 11
2. VC++ Installation
- After successful installation of Java, automatically VC ++ Redistributable 2008 installation
process starts as shown below and Click on “Next”.
Check the box “I have read and accept the license terms” and click on “Install” as shown below.
After Installation, Click on “Finish”.
TCS- BOB Confidential 12
NOTE : If VC++ 2008 x86 is already installed on your computer, then click on Cancel.
After successful installation of VC ++ Redistributable 2008.Browser setting required for Internet
Explorer will be done automatically as shown below.
3. Browser Setting
TCS- BOB Confidential 13
4. Install Precision SDK
After browser setting, BOB BMA Client API will start to install and following wizard will open
for installing BOB BMA Client API, Cogent and Legend drivers as shown below and read the
instruction in the prompt and Click on “OK”.
NOTE: If BOB BMA Client is already installed then it will uninstall and read the following
instructions on the prompt shown below and click on “OK” and then click on “Close” after
successful uninstallation.
TCS- BOB Confidential 14
Following prompt will open and now click on “I Agree” to install BOB BMA Client SDK
as shown below.
5. Install Cogent and Legend drivers
Now Click on “Next” as shown below.
TCS- BOB Confidential 15
After above step , Click on “Install’ as shown below.
Click on “Next” to install Cogent drivers as shown below.
TCS- BOB Confidential 16
Click on “Finish” as shown below.
After Cogent drivers installation , following prompt will open for legend drivers installation.
TCS- BOB Confidential 17
Click on “Close” as shown below.
Installation is successful and now it will prompt to reboot your system. Click on “Yes”.
After Reboot , Open the folder “BOBKiosk_v2.3.6”
TCS- BOB Confidential 18
6. Test Device
Ensure you have logged in with the user having administrative rights.
In “BOBKiosk_v2.3.6” folder, Right click on ‘Test_device.bat’ file and click on ‘Run as
administrator’ as shown below.
TCS- BOB Confidential 19
After opening the “Test_device.bat” , following Internet Explorer window will open
and Click on “Allow blocked content”
Now Click on “Yes” as shown below.
TCS- BOB Confidential 20
Screenshot of Precision’s Cogent Device Testing
After Clicking on “Yes” following window will open to capture your finger print to test whether
your scanner is working properly or not.
Ensure that you have connected or plugged in the device to your system.
Keep your finger on device till it captures 3 times.
Note: - Use same finger 3 times for capturing.
Click on “OK” after getting the following window.
TCS- BOB Confidential 21
If you get following message then it means “Cogent device” is successfully installed and scanner is
working properly.
TCS- BOB Confidential 22
Screenshot of Precision’s Legend Device Testing
Swipe your finger three times with same finger at constant speed
TCS- BOB Confidential 23
If you get above message then it means Legend device is successfully installed and scanner is working
properly.
If you get above message means same finger is not swiped or not swiped correctly. Please try again