IMPROVIA ENERGI Efficiency Quality Reliability IMPROVIA

Company Profile Improvia 1.7

Embed Size (px)

Citation preview

Page 1: Company Profile Improvia 1.7

IMPROVIA ENERGIEfficiency QualityReliability

IMPROVIA

Page 2: Company Profile Improvia 1.7

Our Competence

Why Audit?

Improvement is no doubt a necessity in industrial process. Every design, calculation, forecasting and decision are dinamically done by internal management. We undestand the requirement of second opinion at those steps. By performing audit we deliver recommendations, engineering solutions, objective judgments and other activities related to the audit results to improve efficiency. By improving efficiency, we can also at the same time improving productivity and finally a better quality. Just like common auditors, we put ourself independent so we can recommend the best optimization and improvement.

We use different approach in each case. The method used in auditing process start from the simple way, visual inspection. It is one of few steps to do pre-eliminary inspection. The other thing we need in pre-eliminary/preparation step is technical data, spesification, PFD and P&ID, operation data & maintenance history. We build communication with users, engineers, technicians, planner, operator, production staff and other in order to get the required facts.

Efficiency - Reliability - Quality

Our competence is build according to these 3 important terms in industry; Efficiency, Reliability and Quality. We believe that these 3 terms are related to each others. It becomes basic, goal, purpose and even soul in each work and services we provide.

Page 3: Company Profile Improvia 1.7

Energy Audit

?Operational Data

?Maintenance History

?PFD and P&ID

?Technical Drawing

?Specification, Material

?Interview

?On site Measurement

Quality

?Vibration Monitoring

?Oil Analysis

?Thermal Imaging

?Machinery

performance diagnoze

Condition Monitoring

IMPROVIA

How to improve Efficiency?

?Recommendations

?SOP Review

?Energy Saving

Campaign

?Energy Services

Contract

?Recommendations

?Corrective

Maintenance

?Maintenance Set up &

Planning

?Repair, overhaul

How to improve Reliability?

Page 4: Company Profile Improvia 1.7

Energy Audit

Commercial Audit

Operational cost allocated in power generation generally raised up to 30-40%. Using Cost Benefit Analysis and also by analyzing each equipments used in operational such as air conditioner, heater, lightings, plumbing etc, we give the best recommendation to you!

Energy Audit - Power Plant

Performance monitoring and analysis of power plant equipment have become an essential activity in today’s increasingly energy intensive and competitive power industry. An energy audit will identify the degraded plant components and their contribution to overall thermal efficiency loss. By doing so, it will improve the efficiency. The audit will also give a significant input to operations and maintenance. To examine steam/gas turbine power plant we use Heat Balance Analysis method.

Industrial activity (process or production plant) usually spend many power. To become a leader in the competition ofcourse each industry must to improve efficieny, productivity and quality. For Industrial Facility Audit we provide services such as :

Industrial Facility Audit

Pre-eliminary Assessment (data collection)?Planning and scheduling Assessment/Audit ?activityFormulate Energy Audit concept for each ?equipments or componentsDefine the methods and prepare the forms?Site visit including assessment on the existing ?equipments, analyze, measure and diagnose lossess/deratingFinal reporting and Recommendation?Energy Conservation Training and Consultancy?

Page 5: Company Profile Improvia 1.7

Energy AuditPower Plant

Performance monitoring and analysis of power plant

equipment have become an essential activity in today’s

increasingly energy intensive and competitive power

industry. An energy audit will identify the degraded

plant components and their contribution to overall

thermal efficiency loss. By doing so, it will improve the

efficiency. The audit will also give a significant input to

operations and maintenance. To examine steam/gas

turbine power plant we use Heat Balance Analysis

method.

When we implement Energy Audit for Power Plant, we

calculate efficiency, performance, and also losses that

might occur in system. These parameters are measured

and calculated during the project such as Main Steam

Pressure and Temperature, Main Steam flow, Gross

Power generated, Nett Power Generated, Reheater

Temperature to Turbine, Fuel Rate, FeedWater flow etc.

Our analysis focussed on plant main equipment

including Boiler, HP/IP/LP Turbine, Condenser, Boiler

Feed Pump (BFP), Air Heater, Economizer, Superheater,

Reheater, HP/LP Heater, Generator, Fan, Pumps, Coal

Feeder, Pulverizer. By analyze Heat Balance we

calculate Boiler Efficiency, Heat Loss, Steam Turbine

Performance, Plant Heat Rate, Flue Gas Analysis. Then

we will compare with the commisioning test or the best

achievable efficiency.

In this Audit Work we use several tools such as

thermometer with type-K thermocouple, digital clamp

meter, anemometer, Gas Analyzer and other auxiliary

tools.

Page 6: Company Profile Improvia 1.7

Energy AuditCommercial Building

There are several reasons why do we need energy audit

in commercial building. One of the reason is conducted

from the unpredictable condition on energy availability

nowadays. Because of this situation we have to reduce

our operational cost. Our company would survive by

reducing the unnecessary expenses.

Improving energy efficiency will save more money from

energy expenses. Energy Audit on Commercial Building

is an activity to monitoring the energy usage at

equipments such as HVAC, lighting system, utilities and

etc. By doing so, we can identify the energy saving and

give recommendations about that chance.

Scope of work on Building Energy Audit consist of :

Perform assessment on Heating, Ventilation and

Air Conditioning (HVAC) system. This one

including on-site measurement in order to get the

actual data

Perform assessment on Building Lighting System

Perform assessment on Air compression system (if

any)

Analysis at Building Envelope

Assessment on Building Electrical system

Possibility to use Renewable Energy

Inspect other utilities

The important thing in Building Energy Audit is to

improve efficiency without decreasing quality and

comfort.

?

??

????

Page 7: Company Profile Improvia 1.7

Level of Audit

Building Energy Audit consist of 3 Level, Walk Through

Audit, Audit Level 1 and Audit Level 2. This Level of audit

was developed by American Society of Heating Air

Conditioning and Refrigeration Engineers (ASHRAE).

Walk Through AuditAudit is done by walking through the facilities, identify

the chance to saving energy, perform interview with the

personel in charge, and also quick review of the energy

bill paid by building company. This audit will give the

road map ahead about how to gain energy savings.

Level 1 AuditThis audit is more intensive rather than Walk Through

Audit. The activity consist of more assessment on HVAC,

lighting system and other utilities, also consider energy

conservation with low-cost/no-cost. This level of audit

also can identify category of Green Building.

Level 2 AuditLevel 2 ASHRAE Audit will identify the whole possibility

to saving energy at building facilities, analyze the

financial aspect including implementation cost,

operational cost and cost saving achievement. Analysis

of Payback periode of the planned recommendations is

also considered here. Assessment and investigation

conducted in this level is more detail rather than Level 1

Audit. ASHRAE Level 2 will also discuss the change of

Standard Operating Procedure (SOP) and maintenance

activity.

At Improvia Energi, we adopt this Level of audit and

provide services according to our clients’ need and

budget.

Page 8: Company Profile Improvia 1.7

Work on Building Energy Audit

As explained in previous chapter, in Building Energy

Audit we do these activities :

interview with the personal in charge

monitoring the equipments

collect ing equipments’ data including

spesifications, technical details, manufacturer’s

manual book etc

gathering information such as operational

conditions, procedures, maintenance history

on-site measurement

When we conduct On-Site measurement, there will be

several devices we need to use. To analyze building load

distribution we need Power Analyzer. This instrument

also can measure major electrical parameters such as

kVA, kW, PF, Amps and Volts. To measure surface

temperatures we might need Infrared Thermometer.

This is a non-contact type measurement which when

directed at a heat source directly gives the temperature

read out. Air velocity in ducts can be measured using a

pitot tube and inclined manometer for further

calculation of flows. To measure water flow we can use a

non-contact flow measuring device using Doppler

effect/Ultrasonic principle. There is a transmitter and

receiver which are positioned on opposite sides of the

pipe. The meter directly gives the flow. Illumination

levels are measured with a lux meter. It consists of a

photo cell which senses the light output, converts to

electrical impulses which are calibrated as lux.

???

?

?

Page 9: Company Profile Improvia 1.7

Energy Services Contract

The Contract

It is important to ensure our customers that the output of

Energy Audit is right on the target. By doing so, we also

can monitor how efficiency gained. Each time the audit

performed by combining the assessment & inspection

result, technical evaluation, cost benefit analysis and

also management consideration. As an output, the

recommendations consist of 2 (two) options :Improvement with Low Cost such as SOP Review,

habit fixes, energy saving campaign etcImprovement with High Cost including

maintenance review, repair & overhaul, parts

replacement or upgrading etc

By Energy Services Contract, all the improvement cost

stated above and also the implementation become our

responsibility. The cost saving achievement will be

shared between Improvia Energi and clients. The share

percentage depend on agreement.

?

?

The Idea

Through the energy audit we deliver recommendations about how to uprate efficiency or how to save energy. Energy saving is also connected to Cost Saving. Beside the recommendations, we also offer to our valued customers an Energy Services Contract. This contract made by agreement from both of sides. The idea is that customer only pay us for each ‘cost saving’ we deliver.The benefits for clients are :

The energy audit result can be justified by monitoring the implementationLow risk for clients because all cost, preparation and activities in order to implement the energy conservation will be conducted by our company

?

?

Page 10: Company Profile Improvia 1.7

Condition Base Monitoring

Vibration Monitoring is one of the method used in Condition Base

Monitoring (CBM). Vibration monitoring is defined in this 2 area :

Rotating Engine (pump, turbine, generator, motor, ?compressor, fan, blower etc)

Reciprocating (Diesel Engine, Gas Engine, Recip ?Compressor)

Vibration Monitoring

Review, Audit and Assessment for existing monitoring ?procedures

Design, setup and install the new Vibration Monitoring ?System

Analyze vibration machinery problems?Examination Planning & Scheduling?Training & Consultancy?

Reliability is no doubt an important key in modern maintenance

management system. One of methods to improve reliability is the

implementation of Condition Based Monitoring (CBM). This

method is more comprehensive and cost effective concepts. The

concept is based on the belief that if equipment can be evaluated

and yet still remain in service, the overall cost of maintenance will

go down. Beside reducing the level time based maintenance,

CBM will catch ill conditioned components before they break and

cause unplanned outages. By implementing CBM we can

measure the health of the machinery, engine performance,and

also engine vibration.

By implementing Vibration Monitoring we can detect :?Unbalance?Misalignment?Bearing problems?Mechanical looseness?etc

We provide services :

30

40

50

60

70

80

90

100

110

0 45 90 135 180 225 270 315 360

--------------

--------------

--------------

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

- Scale 2.0

31 DGC

- Scale 4.9

107 DGC

1HS1 VT1

1HD1 VT1

C402 - C cylinder 1 09/09/1998 12:02:53 HE Period 9Channel Resonance is corrected

Pr

es

su

re

(b

ar

g)

Crank Angle (deg)

Page 11: Company Profile Improvia 1.7

Our Experiences

Software Maintenance System, RS Pondok Indah, December 2010.

We develop and design a system to make the maintenance activity efectively.

Root Cause Failure Analysis on Shell Crack at Feed-End Shell Dryer #3D, PT INCO, Sorowako, 2010

We analyze the crack failure by visual inspection & Fractography, In-situ Metallography, hardness testing, ultrasonic thickness measurement and also finite element simulation methode

HSE Consultancy, PT Indah Dewi, Tarakan, 2011

In this service we develop Health, Safety and Environment (HSE) Procedures for PT Indah Dewi, one of the heavy equipment contractor in Tarakan, East Kalimantan

Assist on Predictive Maintenance (PdM) Activity at Star Energy (Kakap) Natuna, KH-KRA-KG-KF Platform, 2011

The activity consist of Vibration Monitoring on Rotating and Reciprocating Engine, Thermography, and Oil Analysis. The main equipments are Gas Engine, Diesel Engine, Gas Turbine, Gas Compressor, Air Compressor, Pumps, Fan etc.

Jasa Audit Energi PLTU Unit 5-7 Tahap l, PT Indonesia Power UBP Suralaya, 2011

We perform full assessment at the plant to examine the real net plant efficiency, plant heat rate and losses. We do the audit works at Boiler, Turbine, Condenser, Boiler Feed Pump (BFP), Air Heater etc.

Vibration Analysis at Boiler FeedWater Pump #1, PLTU Sebalang, Lampung, 2012

The assessment was conducted on BFP #1 due to high vibration on axial side. We analyzed the engine by using CSI-2130.

Vibration Analysis of 89 (Eighty Nine) Equipments, Cilegon Plant, PT. Cabot Indonesia, 2012

Vibration analysis was performed for plant equipments such as Pumps, Fans, Compressors, Turbine, Gearbox etc.

Page 12: Company Profile Improvia 1.7