7/30/2019 Compact Fp Mair It At
1/19
OverviewThe National Instruments [c]FP-AI-1xx devices are versatile analog
input modules for Compact FieldPoint and FieldPoint that can be
used to measure voltages ranging from the millivolt level to the
120 V high-voltage level in applications such as battery-pack
monitoring, fuel-cell testing, and general measurement from
transducers. These modules can also measure 0 to 20 or 4 to 20 mA
current loops from industrial sensors and transmitters. All the
modules include overranging and onboard diagnostics to ensure
trouble-free installation and maintenance. The modules measure and
linearize signals on-board to return scaled values to your control
or monitoring software. The [c]FP-AI-1xx modules come with
NIST-traceable calibration certificates, ensuring accurate and reliable
analog measurements.
Smart I/O ModulesWith [c]FP-AI-1xx analog input modules, you can directly connect toyour industrial sensors or units under test and get high-accuracy
measurements. The I/O modules filter, calibrate, and scale raw sensor
signals to engineering units, as well as performing self-diagnostics to
look for problems with the module or the wiring. With FieldPoint
modules, your software application reads a linearized, calibrated, and
scaled value from the I/O module, eliminating the error-prone step of
converting binary values to voltage or current values. For increased
accuracy and noise rejection, the [c]FP-AI-110 and [c]FP-AI-111 use a
16-bit delta-sigma ADC with an integrated lowpass filter on each
channel, which you can configure for 50 Hz, 60 Hz, or no rejection.
With high-accuracy 12-bit ADCs or 16-bit delta-sigma ADCs on the
I/O modules, you also get instrument-quality measurements on an
industrially rugged, distributed, embedded system.
[c]FP-AI-1xx modules offer a variety of update rates to fit your
application, ranging from 0.66 to 360 Hz. These rates vary based on
the module used and on the noise filter settings selected on the
module. Overall data throughput depends on software loop speeds
and network speeds. With overranging and underranging, the
[c]FP-AI-1xx analog input modules can measure inputs or sensorsthat are not calibrated to standard ranges. For example, when
configured for an input range of 4 to 20 mA, the modules actually
measure inputs from 3.5 to 21 mA.
Analog Input Modules forCompact FieldPoint and FieldPoint
8 or 16 voltage or current inputs
120 V input range, maximum 0 to 20, 4 to 20 mA input ranges
Built-in signal conditioning 50, 60, and 500 Hz noise rejection
12 and 16-bit resolution Software-configurable input ranges per
channel 2,300 Vrms bank isolation for transient
overvoltage protection Hot-swappable with autoconfiguration -40 to 70 C operating range
NI [c]FP-AI-100, NI [c]FP-AI-102,NI [c]FP-AI-110, NI [c]FP-AI-111
NEW
Input Ranges All-Channel
Module Input Channels Resolution Input Type (Software Configurable per Channel) 50/60 Hz Noise Filter Update Rate
[c]FP-AI-100 8 12 bits Voltage 1 V, 5 V, 15 V, 30 V, 0 to 1 V, 0 to 5 V, 0 to 15 V, 0 to 30 V 360 Hz
Current 0 to 20 mA, 4 to 20 mA, 20 mA
[c]FP-AI-102 8 12 bits Voltage 20 V, 60 V, 120 V, 0 to 20 V, 0 to 60 V, 0 to 120 V 360 Hz
[c]FP-AI-110 8 16 bits Voltage 60 mV, 300 mV, 1 V, 5 V, 10 V, 0 to 1 V, 0 to 5 V, 0 to 10 V 5 Hz to 0.66 Hz
Current 0 to 20 mA, 4 to 20 mA, 20 mA (software selectable) (rate varies with filter settings)
[c]FP-AI-111 16 16 bits Current 0 to 20 mA, 4 to 20 mA, 20 mA 3 Hz to 0.83 Hz
(software selectable) (rate varies with filter settings)
7/30/2019 Compact Fp Mair It At
2/19
Thermocouple and RTD Modules for Compact FieldPoint
Overview
The National Instruments cFP-TC-12x and cFP-RTD-12x are versatile
temperature input modules for Compact FieldPoint, used to measure
thermocouples, millivolt-level voltages, thermistors, and 2, 3, and 4-wire
RTDs. They are used in applications such as temperature chamber control,
device testing, and process control. Thermocouples are low-cost, flexible
temperature devices. RTD sensors are used in applications for acquiring
temperatures with high accuracy. Two and 3-wire RTDs work well for
applications with short signal wires and low noise levels; 4-wire RTDs are
well-suited for applications with long signal wires or high noise levels.
All of these I/O modules include overranging and onboard diagnostics to
ensure trouble-free installation and maintenance. The modules measure
and linearize signals on board to return scaled values to your control or
monitoring software. NI cFP-TC-12x and cFP-RTD-12x modules have NIST-
traceable calibration certificates (available on request), ensuring accurate
and reliable analog measurements.
Compact FieldPoint
Compact FieldPoint is designed for industrial control applications that
perform advanced embedded control, data logging, headless operation,
and Ethernet connectivity. Compact FieldPoint, a rugged, reliable NI platform,
is designed for industrial and mobile environments with high shock,
vibration, and temperature extremes.
Isolation
The cFP-TC-125 provides 250 Vrms common-mode voltage protection
between channels, and all cFP-TC-12x and cFP-RTD-12x modules
feature optical bank isolation with 2,300 Vrms of breakdown isolation.
In addition, the cFP-TC-12x and cFP-RTD-12x provide double insulation
for up to 250 Vrms of operational isolation. You can safely use Compact
FieldPoint with the cFP-CB-1 or cFP-CB-3 connector block in applications
where hazardous voltages are present.
8 temperature inputs
Thermocouple or millivolt
2, 3, or 4-wire RTD
Built-in signal conditioning
between channels
250 V common-mode isolation
on TC-125
50 and 60 Hz noise rejection
16-bit resolution
Input ranges configurable in software
for each channel
2,300 Vrms bank isolation for transient
overvoltage protection
Hot-swappable with autoconfiguration
-40 to 70 C operating range
NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124
Module
Input
Channels
Resolution
(bits) Input Type
Input Ranges Software
Configurable per Channel
50/60 Hz
Noise Filter
All-Channel
Update Period
Common-Mode
Between Channels
Safety
Isolation
cFP-TC-120 8 16 Thermocouple J,K,R,S,T,N,E, and B 25 mV, 50 mV, 1.13 s (0.88 Hz) 2,300 Vrmsbank isolationMillivolt 100 mV, -20 to 80 mV
cFP-TC-125 8 16 Thermocouple J,K,R,S,T,N,E, and B 0.22 s (Filter Off)
0.99 s (Filter On)
250 Vrms 2,300 Vrmsbank isolationMillivolt -20 to 80 mV
cFP-RTD-122 8 16 2, 3-Wire RTD Pt 100, Pt 1,000 1.08 s (0.93 Hz) 2,300 Vrmsbank isolationResistance 0 to 400, 0 to 4000
cFP-RTD-124 8 16 2, 4-Wire RTD Pt 100 1.08 s (0.93 Hz) 2,300 Vrmsbank isolationResistance 0 to 400
7/30/2019 Compact Fp Mair It At
3/19
Smart I/O ModulesThe cFP-TC-12x and cFP-RTD-12x modules offer 16-bit resolution for
high-accuracy measurements, and you can connect directly to industrial
sensors or units under test with the safety isolation available. The modulesfilter, calibrate, and scale raw sensor signals to engineering units, as
well as perform self-diagnostics to look for problems such as open
thermocouples. With cFP-TC-12x and cFP-RTD-12x modules, your software
application reads a linearized, calibrated, scaled value from the I/O module,
eliminating the error-prone step of converting binary values to temperature.
For increased accuracy and noise rejection, the modules use a
16-bit delta-sigma ADC with an integrated lowpass filter on each
channel, which is configured for 50 and 60 Hz rejection. With high-accuracy
16-bit delta-sigma ADCs on the I/O modules, you also get instrument-quality
measurements on an industrially rugged, distributed, embedded system.
cFP-TC-12x and cFP-RTD-12x modules offer a variety of different updaterates to fit your application, ranging from 0.22 s with filters off and 1.08
to 1.13 s with f ilters enabled. Overall data throughput depends on filter
settings across all channels, software loop speeds, and network speeds.
cFP-TC-120The cFP-TC-120 includes eight differential inputs for thermocouples.
It also provides cold-junction compensation using a thermistor embedded
in the connector block. An onboard microcontroller compensates and
linearizes the thermocouple reading to the NIST IST-90 standard,
using an advanced linearization routine for maximum accuracy.
cFP-TC-125In addition to the thermistor and linearization features of the cFP-TC-120,
the cFP-TC-125 provides 250 Vrms of common-mode rejection, ideal for
applications where differences in voltages might exist between connected
thermocouples. The cFP-TC-125 also provides 0.22 s update rates when
the 50/60 Hz filter is not enabled.
cFP-RTD-122The cFP-RTD-122 includes eight inputs for 2 and 3-wire RTDs.
The module uses a stable current source for sensor excitation and an
onboard microcontroller that linearizes and scales the measurements to
temperature units. You can configure each channel of the module to
return data scaled to temperature (C, F, or K) or resistance. The 3-wire
configuration used with the cFP-RTD-122 eliminates errors caused by
lead wire resistance but does not reduce errors caused by noise. If your
application involves high noise or long wires, you should use 4-wire RTDs
with the cFP-RTD-124.
cFP-RTD-124The cFP-RTD-124 includes eight inputs for 2 and 4-wire RTDs. The module
uses a stable current source for sensor excitation and an onboard
microcontroller that linearizes and scales the measurements to temperature
units. You can configure each channel of the modules to return data scaled
to temperature (C, F, or K) or resistance. Four-wire RTDs used with the
cFP-RTD-124 are ideal for applications involving long signal wires or high
signal noise. The 4-wire configuration eliminates the voltage drop caused
by lead wire resistance and reduces errors caused by noise.
Isothermal Connectivity for the cFP-TC-12xFor maximum accuracy, NI recommends using an isothermal connector
block with the cFP-TC-12x. The cFP-CB-3 isothermal connector block
minimizes the temperature gradient across wiring connections,
improving the accuracy of the cold-junction measurement, and,
therefore, of thermocouple measurements.
Compact FieldPoint I/O Connections
Compact FieldPoint modules include a built-in power distribution bus
that provides multiple power connections on the module. A field-wired
power supply connected to the voltage (V) and common (C) terminals is
internally connected to a power distribution bus that provides additional
breakout terminals for voltage supply (VSUP) and common (COM). These
terminals offer a convenient way to distribute power to field devices that
require external power.
Each cFP-TC-12x input channel has two terminals for differential input:
1. Thermocouple positive input (IN+)2. Thermocouple negative input (IN-)
Each cFP-RTD-122 input channel has three terminals:
1. Excitation output (EXCITE)
2. Sensing input (SENSE)
3. Common input (COM)
Each cFP-RTD-124 input channel has four terminals:
1. Excitation output (EXCITE)
2. Positive sensing input (SENSE+)
3. Negative sensing input (SENSE-)
4. Common input (COM)
Thermocouple and RTD Modules for Compact FieldPoint
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
7/30/2019 Compact Fp Mair It At
4/19
OverviewThe National Instruments [c]FP-SG-140 is a versatile resistance bridge
input module for Compact FieldPoint and FieldPoint that can be used to
measure values from resistor bridges including full and half-bridge strain
gauges, quarter-bridge strain gauges (using an external completion
register), and load and torque sensors. The [c]FP-SG-140 includes built-
in excitation,overranging,and onboard diagnostics to ensure trouble-free
installation and maintenance.The module measures and linearizes signals
onboard to return scaled values to your control or monitoring software.
The [c]FP-SG-140 comes with a NIST-traceable calibration certificate,
ensuring accurate and reliable analog measurements.
Smart I/O ModulesWith the SG-140, you can connect directly to industrial sensors or
units under test and get high-accuracy measurements. The module
filters, calibrates, and scales raw sensor signals to engineering units, as
well as performing self-diagnostics to look for problems with the
module or with the wiring. With the SG-140 module, your software
application reads a linearized,calibrated,and scaled value from the I/O
module, eliminating the error-prone step of converting binary values.Because the [c]FP-SG-140 measures in units of millivolts per volt, it
can interface with a wide variety of transducers, such as load cells and
pressure sensors. The module uses a pulsed excitation of up to
21 mA per channel that turns on and off the excitation to each channel.
This reduces self-heating effects and provides more accurate and
repeatable strain measurements. The [c]FP-SG-140 also provides true
ratiometric readings to eliminate errors caused by variations in
excitation voltage. Each channel on the module can be configured for a
different excitation level of 2.5, 5, or 10 V. For increased accuracy and
noise rejection, the [c]FP-SG-140 uses a 16-bit delta-sigma ADC with
an integrated lowpass filter on each channel, which you can configure
for 15, 60, or 240 Hz. With a high-accuracy 16-bit delta-sigma ADC,
you also get instrument-quality measurements on an industrially
rugged, distributed, embedded system.
The [c]FP-SG-140 has three update rates to fit your application,
ranging from 0.87 to 1.11 Hz. These rates vary based on the noise filter
setting selected on the module. Overall data throughput depends on
software loop speeds and network speeds. With overranging and
underranging,the modules can zero out unstrained readings in software
to compensate for field devices with span errors of up to 12 percent.
IsolationThe [c]FP-SG-140 features optical bank isolation with 2,300 Vrms of
breakdown isolation. These Compact FieldPoint and FieldPoint
modules do not have channel-to-channel isolation.
Field I/O Connections
Compact FieldPoint and FieldPoint modules include a built-in powerdistribution bus that provides multiple power connections on the
module. A field-wired power supply connected to the voltage (V) and
common (C) terminals is internally connected to a power distribution
bus that provides additional breakout terminals for voltage supply
(VSUP) and common (COM). These terminals provide a convenient
way to distribute power to field devices that require external power.
Strain Gauge Modules forCompact FieldPoint And FieldPoint
Accept full and half-bridge straingauge inputs directly
Quarter-bridge gauges require externalbridge-completion resistor Compatible with load cells, force
sensors, and torque sensors Built-in signal conditioning
15, 60, and 240 Hz noise rejection Pulsed excitation to prevent
self-heating
16-bit resolution Input ranges software configurable per
channel 2,300 Vrms bank isolation for transientovervoltage protection
Hot-swappable with autoconfiguration
-40 to 70 C operating range
NI [c]FP-SG-140 NEW
Input Ranges 15/60/240 Hz
Module Input Channels Resolution (Software Configurable per Channel) Noise Filter All Channel Update Rate
[c}FP-SG-140 8 16 bits 3.5 mV/V, 7.5 mV/V, 30 mV/V, 60 mV/V Software selectable 1.11 to 0.87 Hz (rate varies with filter settings)
7/30/2019 Compact Fp Mair It At
5/19
Each input channel on the [c]FP-SG-140 has four terminals:
1. Excitation voltage output (Vexc)
2. Positive signal input (VIN+)
3. Negative signal input (VIN-)
4. Common input (COM)
Strain Gauge Modules forCompact FieldPoint And FieldPoint
2 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
Compact FieldPointNI cFP-SG-140 ............................................................777318-140
Recommended Compact FieldPoint System ProductsNI cFP-2020 ..............................................................777317-2020NI cFP-BP-4 ..................................................................778617-04NI cFP-CB-1..................................................................778618-01NI PS-5 Power Supply ..................................................778805-90NI Developer Suite Professional Control Edition..........777906-03
FieldPointNI FP-SG-140..............................................................777518-140
Recommended FieldPoint System ProductsNI FP-1601 ....................................................................777792-01NI FP-TB-1....................... .............................................777519-01PS-4 Power Supply...................................... ..................778586-90NI Developer Suite Standard Control Edition ............777905-03
BUY ONLINE!
Visitni.com/infoand enter cfpsg140, and/or fpsg140.
Ordering Information
Typical for -40 to 70 C unless otherwise noted.
Input CharacteristicsNumber of inputs ............................................. 8 differential
Resolution......................................................... 16 bits, 1 in 65,536
Type of ADC...................................................... Delta-sigma
Filters ............................................................... 15, 60, 240 Hz, user-selectable
Excitation voltage............................................. 2.5, 5, 10 V, user-selectable,
current-limited to 21 mA per c hannel
Bridge configurations....................................... Half and full-bridge circuits, quarter-bridge with external
completion resistor
Gauge factor..................................................... Any (software value)
Input impedance............................................... 20 M
Offset error15 to 35 C................................................. 7.6 V typ, 28 V max
40 to 70 C............................................... 50 V typ, 140 V max
Gain error
15 to 35 C ................................................. 0.06%
40 to 70 C............................................... 0.4%
Input noise (60 Hz filter)
3.5 mV/V................................................. 3 LSBpp 7.5 mV/V................................................. 2 LSBpp
Other ranges..................................................... 1 LSBppAll-channel update periods
15 Hz.......................................................... 1.15 s
60 Hz.......................................................... 0.95 s
240 Hz........................................................ 0.90 s
Isolation VoltageMaximum isolation voltage............................. 250 V rms, Installation Category II
Channel-to-channel isolation........................... No isolation between channels
Transient overvoltage....................................... 2,300 Vrms
Physical CharacteristicsLED indicators
POWER (green).......................................... Power on and self-test passed
READY (green)........................................... Module configured and ready
OVERCURRENT (red).................................. Overcurrent condition on channel
Dimensions (including terminal base).............. 10.9 by 10.7 by 9.1 cm (4.3 by 4.2 by 3.6 in.)
Weight
FP-SG-140.................................................. 140 g (4.8 oz)
cFP-SG-140 ................................................ 110 g (3.7 oz)
Power RequirementPower from network module............................ 1,000 mW
EnvironmentalFieldPoint modules are intended for indoor use only. For outdoor use, they must be mounted inside
a sealed enclosure.
Operating temperature..................................... -40 to 60 C
Storage temperature........................................ -55 to 85 C
Relative humidity ............................................. 10 to 90%, noncondensing
Maximum altitude............................................ 2,000 m; at higher altitudes the isolation voltage
ratings must be lowered.
Pollution degree ............................................... 2
Shock and VibrationThese specifications apply only to Compact FieldPoint. NI recommends Compact FieldPoint if your
application is subject to shock and vibration.
Operating vibration, random(IEC 60068-2-64)........................................ 10500 Hz, 5 grms
Operating vibration, sinusoidal
(IEC 60068-2-6).......................................... 10500 Hz, 5 g
Operating shock
(IEC 60068-2-27)........................................ 50 g, 3 ms half sine, 18 shocks at 6 orientations;
30 g, 11 ms half sine, 18 shocks at 6 orientations
SafetyThis product is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 3121-1, UL 61010C-1
CAN/CSA C22.2 No. 1010.1
For UL, hazardous location, and other safety certifications, refer to the product label or to ni.com
Electromagnetic CompatibilityCE, C-Tick, and FCC Part 15 (Class A) Compliant
Emissions.......................................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity........................................................... EN 61326:1997 +A2:2001, Table 1For EMC compliance, you must operate this device with shielded cabling.
CE ComplianceThis product meets the essential requirements of applicable European Directives, as amended for
CE Marking, as follows:
Low-Voltage Directive (safety)......................... 73/23/EEC
Electromagnetic Compatibility
Directive (EMC) ................................................ 89/336/EEC
Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance
information. To obtain the DoC for this product, visit ni.com/hardref.nsf/and search by model number
or product line.
Specifications
ExcitationVoltage
[c]FP-SG-140
COM
Vin+
Vexc
Vin
Quarter-BridgeStrain Gauges
InputCircuitry
+
ExternalCompletion
Resistor
ExcitationVoltage
[c]FP-SG-140
COM
Vin+
Vexc
Vin
Half-BridgeStrain Gauges
InputCircuitry
+
COM
Vin+
Vexc
Vin ExcitationVoltage
Full-BridgeStrain Gauge
[c]FP-SG-140
InputCircuitry +
Figure 1. Wiring Schematic for the [c]FP-SG-140 Module
7/30/2019 Compact Fp Mair It At
6/19
OverviewThe National Instruments [c]FP-AO-2xx devices are versatile analog
output modules for Compact FieldPoint and FieldPoint that can be
used to control valves, gauges, and other industrial actuators. All
modules include overranging and onboard diagnostics to ensure
trouble-free installation and maintenance. The modules accept
engineering units from you, control or monitoring software and
linearize and output scaled signals. The NI [c]FP-AZ-2xx modules
come with NIST-traceable calibration certificates, ensuring accurate
and reliable analog control.
Smart I/O ModulesWith AO-2xx modules, you can directly connect to your industrial
actuators or units under test and get high-accuracy control. The I/O
modules calibrate, and scale engineering units to sensor signals, as
well as performing self-diagnostics to look for problems with the
module or with the wiring such as open current loops. With AO-2xx
modules, your software application writes an engineering value to
the I/O module, eliminating the error-prone step of converting
voltage or current to binary values. The A0-2xx modules have anupdate rate of 200 Hz. Overall data throughput to the controller or
PC depends on the software loop speeds and the network speeds.
The [c]FP-AO-200 includes eight 0 to 20 mA or 4 to 20 mA analog
output channels, generated with a 12-bit DAC. Each output channel
includes a monitoring circuit and LED indicator for open current
loop detection. The AO-200 requires an external power supply
that provides 5 to 24 VDC.
The [c]FP-AO-210 includes eight 0 to 10 V output channels,
generated with a 12-bit DAC. Each channel provides a voltage source
capable of supplying up to 1 mA. You can obtain up to 10 mA by
powering the AO-210 with an optional external power supply of
15 to 30 VDC.
IsolationThe AO-xx series modules feature optical bank isolation with2,300 Vrms of breakdown isolation. These Compact FieldPoint and
FieldPoint modules do not have channel-to-channel isolation.
Field I/O ConnectionsCompact FieldPoint and FieldPoint modules include a built-in power
distribution bus that provides multiple power connections on the
module. A field wired power supply connected to the voltage (V) and
common (C) terminals is internally connected to a power distribution
bus that provides additional breakout terminals for voltage supply
(VSUP) and common (COM). These terminals provide a convenient
way to distribute power to field devices that require external power.
The AO-200 has: 8 current output terminals (IOUT)
16 common terminals (COM)
8 power connections for field devices or current loops (VSUP)
The AO-210 has:
8 voltage output terminals (VOUT)
16 common terminals (COM)
8 power connections for field devices or current loops (VSUP)
Analog Output Modules forCompact FieldPoint and FieldPoint
8 voltage or current outputs 0 to 10 V
0 to 20, 4 to 20 mA 12 -bit resolution Output ranges software configurable
per channel 2,300 Vrms bank isolation for transient
overvoltage protection Hot swappable with auto-
configuration -40 to 70 C operating range
NI [c]FP-AO-200, NI [c]FP-AO-210 NEW
Module Input Channels Resolution Output Types Output Ranges (Software Configurable per Channel) All Channel Update Rate
[c}FP-AO-200 8 12 bits Current 0 to 20 mA, 4 to 20 mA 200 Hz
[c}FP-AO-210 8 12 bits Voltage 0 to 10 V, (up to 10 mA/ch) 200 Hz
7/30/2019 Compact Fp Mair It At
7/19
OverviewThe National Instruments [c]FP-AIO-600 is a versatile combination
analog input and analog output modules for Compact FieldPoint and
FieldPoint that can be used to measure voltages and
0 to 20 or 4 to 20 mA current loops from industrial sensors and
transmitters and to control valves, gauges, and other industrial
actuators. The NI [c]FP-AIO-600 is ideal for low-channel-count
systems or for PID control with high speed I/O. The module has
overranging and onboard diagnostics to ensure trouble-free
installation and maintenance. The [c]FP-AIO-600 measures and
linearizes signals onboard to return scaled values to your control or
monitoring software and accept engineering units from you control or
monitoring software and automatically scale and linearize output
signals. The [c]FP-AIO-600 module comes with a NIST-traceable
calibration certificate, ensuring accurate and reliable analog
measurement and control.
Smart I/O ModulesYou can connect the [c]FP-AIO-600 directly to industrial actuators or
units under test and get high-accuracy measurement and control.
The module calibrates, and scales engineering units to sensor signals,
as well as performing self-diagnostics to look for problems with the
module or with the wiring, such as open current loops. With the
[c]FP-AIO-600s, your software application reads and writes
engineering values from the module, eliminating the error-prone
step of converting voltage or current to binary values.
The module has an update rate of 1.7 kHz. Overall data throughput
depends on the software loop speeds and the network speeds.
[c]FP-AIO-600The [c]FP-AIO-600 includes four 0 to 30 V or 0 to 20/4 to 20 mA
analog inputs and four 0 to 20/4 to 20 mA analog outputs. The
analog inputs and outputs use a 12-bit DAC. Each output channel
includes a monitoring circuit and LED indicator for open current
loop detection. The [c]FP-AIO-600 requires an external powersupply,providing 5 to 30 VDC.
Analog Input/Output Combination Modulesfor Compact FieldPoint and FieldPoint
4 voltage or current inputs 30 V
0 to 20, 4 to 20 mA 4 current outputs 0 to 10 V 0 to 20, 4 to 20 mA
12-bit resolution Input and output ranges software
configurable per channel 2,300 Vrms bank isolation for transient
overvoltage protection Hot swappable with autoconfiguration -40 to 70 C operating range
NI [c]FP-AIO-600 NEW
Input Ranges Output Ranges All Channel
Module Input Channels (Software Configurable per Channel) Output Channels (Software Configurable per channel) Resolution Update Rate
[c}FP-AIO-600 4 Current 0 to 20 mA, 4 to 20 mA 4 Current: 0 to 20 mA, 4 to 20 mA 12 b its 1 .7 kHz
Voltage 5 V, 15 V, 30 V, 0 to 5 V, 0 to 15 V, 0 to 30 V
7/30/2019 Compact Fp Mair It At
8/19
Digital Input Modules for Compact FieldPoint and FieldPoint
Overview
The National Instruments [c]FP-DI-3xx devices are versatile digital input
modules. The DI-300, DI-301, and DI-330 are available in the Compact
FieldPoint and FieldPoint product families. The new NI cFP-DI-304 module
is available for Compact FieldPoint systems. You can use these modulesto monitor digital signals ranging from low voltage levels up to 250 V.
They are commonly used to monitor proximity and limit switches,
pushbutton switches, thermostat outputs, relay closures, power circuits,
and TTL devices. All the modules include onboard diagnostics to ensure
trouble-free installation and maintenance.
Digital Input Modules
The [c]FP-DI-3xx modules provide built-in module-to-module isolation to
protect your FieldPoint system and controller or communication interface
from high voltage levels. The DI-300, DI-301, and DI-304 modules use a
common ground plane for all the input channels. Each channel on the DI-300,DI-301, and DI-304 modules include current-limiting circuitry to prevent
module damage when connected directly to a 24 VDC source. The DI-330
uses eight optically isolated input channels so that each digital input has
a separate ground plane, and you can use each channel with a different
voltage potential. Thus, you can connect one channel to a 5 VDC TTL signal
and another signal on the same DI-330 module to a 250 VAC line voltage.
Each channel on the DI-330 includes current-limiting circuitry that limits the
total current to 1.5 mA to prevent damaging the module. All channels on
the DI-3xx modules feature LEDs that indicate the input state of each
channel. The modules feature an all channel update rate of 1 kHz. Overall
data throughput depends on software loop speeds and network speeds.
Isolation
The [c]FP-DI-3xx modules feature bank isolation with 2,300 Vrms of
breakdown isolation. In addition, the DI-330 provides double insulation
for up to 250 Vrms of operational isolation. You can safely use Compact
FieldPoint in applications where hazardous voltages are present when
used with the cFP-CB-1 connector block. You can safely use FieldPoint in
applications where hazardous voltages are present with the FP-TB-x
terminal base. These Compact FieldPoint and FieldPoint modules do not
have channel-to-channel isolation.
Field I/O Connections
Compact FieldPoint and FieldPoint modules include a built-in powerdistribution bus that provides multiple power connections on the module.
A field wired power supply connected to the voltage (V) and common (C)
terminals is internally connected to a power distribution bus that delivers
additional breakout terminals for voltage supply (VSUP) and common
(COM). These terminals offer a convenient way to distribute power
to field devices that require external power.
8,16, or 32 channel inputs
24 VDC inputs 4 to 250 VDC inputs
15 to 250 VAC inputs (50/60 Hz AC)
3 to 250 VAC inputs (1 kHz AC)
2,300 Vrms bank isolation for transientovervoltage protection
Hot-swappable with autoconfiguration
-40 to 70 C operating range
FieldPoint Software (included) FieldPoint 5.0 (for all models)
NI [c]FP-DI-300, NI [c]FP-DI-301,NI cFP-DI-304, NI [c]FP-DI-330 NEW!
Module Input Channels Input Ranges Input Type Compatibility Examples
Separate Ground
Plane per Channel
All Channel
Update Rate
Additional
Features[c]FP-DI-300 8 18 to 30 VDC Sinking 24 VDC sourcing devices 1 kHz
[c]FP-DI-301 16 18 to 30 VDC Sinking 24 VDC sourcing devices 1 kHz
cFP-DI-304 32 10 to 30 VDC Sinking 24 VDC sourcing devices 1 kHz Hysteresis
[c]FP-DI-330 8 5 to 48 VDC
5 to 250 VAC
Sinking or sourcing TTL, CMOS, 12 VDC, 24 VDC,
48 VDC, 120/240 VAC/VDC 1 kHz Input current limiting
(1.5 mA)
7/30/2019 Compact Fp Mair It At
9/19
Digital Input Modules for Compact FieldPoint and FieldPoint
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
To next channel
[c]FP-DI-330
VSUP (Ch 0)
COM (Ch 0)
V C
+
InputCircuitryINB (Ch 0)
INA
(Ch 0)Sinking-Output
Device withExternal
Power
VSUP (Ch 1)
COM (Ch 1)
INB (Ch 1)
INA (Ch 1)
VSUP (Ch 2)
COM (Ch 2)
INB
(Ch 2)
INA (Ch 2)
InputCircuitry
InputCircuitry
+
Sourcing-Output
Device withExternalPower
Sinking-OutputDevice
Powered by[c]FP-DI-330
VSUP (Ch 3)
COM (Ch 3)
INB (Ch 3)
INA (Ch 3)
InputCircuitry
Sourcing-OutputDevice
Powered by[c]FP-DI-330
VSUP (Ch n)
COM (Ch n)
INB (Ch n)
INA (Ch n)
InputCircuitry
+ 5-250 V ExternalPower Supply
SwitchTo next channel
[c]FP-DI-300/301/304
VIN (Ch 0)
VSUP (Ch 0)
COM (Ch 0)
V C
InputCircuitry
SourcingOutput
Device withExternalPower
+
VIN (Ch 1)
VSUP (Ch 1)
COM (Ch 1)
InputCircuitry
SourcingOutputDevice
Powered by
[c]FP-DI-30x
VIN (Ch n)
VSUP (Ch n)
COM (Ch n)
InputCircuitry
+
15-30 VDCExternal Power
Supply
Switch
Wiring Schematics for the [c]FP-DI-3xx Modules
Ordering Information
Compact FieldPoint
NI cFP-DI-300 ........................... ............................ ...............777318-300
NI cFP-DI-301 ............................. ............................. ............777318-301
NI cFP-DI-304 ............................. ............................. ............777318-304
NI cFP-DI-330 ........................... ............................ ...............777318-330
Recommended Compact FieldPoint System Products
NI cFP-2120 ......................... ........................... ..................777317-2120
NI cFP-BP-4............................................................................778617-04
NI cFP-BP-8............................................................................778617-08
NI cFP-CB-1............................................................................779618-01
NI PS-5 Power Supply ............................ ............................ ..778805-90
NI Developer Suite Professional Control Edition..................777906-03
FieldPoint
NI FP-DI-300 .......................... ............................ ..................777518-300
NI FP-DI-301 ......................... ............................ ...................777518-301
NI FP-DI-330 .......................... ............................ ..................777518-330
Recommended FieldPoint System Products
NI FP-1601 ............................ ............................ ....................777792-01NI FP-TB-1..............................................................................777519-01
NI PS-4 Power Supply ............................ ............................ ..778586-90
NI Developer Suite Control Edition ........................... ...........777905-03
BUY NOW!
For complete product specifications, pricing, and accessoryinformation, call (800) 813 3693 (U.S.) or go to ni.com.
7/30/2019 Compact Fp Mair It At
10/19
OverviewThe National Instruments [c]FP-DO-4xx devices are versatile digital
output modules for Compact FieldPoint and FieldPoint that can be
used to control digital signals ranging from 5 to 30 volts. These
modules are commonly used to control indicator lights, external
relays, and CMOS and TTL devices. All the modules include onboard
diagnostics to ensure trouble-free installation and maintenance.
Digital Output ModulesThe DO-4xx modules provide built-in module-to-module isolation
to protect your FieldPoint system and controller or communication
interface from high voltage levels. All the digital output modules use
a common ground plane for the digital output channels.
The DO-400 and DO-401 modules are sourcing digital output
modules capable of providing up to 2 A per channel, with a
maximum power limit across the entire module as explained in the
specifications section.
The DO-403 modules are sinking digital output modules capable
of providing up to 2 A per channel, with a maximum power limit
across the entire module as explained in the specifications section.
The DO-410 modules are sourcing digital output modules capable
of providing up to 1 A per channel. They also feature an electronic fuse
that will prevent damage to the module due to short circuits or other
overcurrent situations. The fuses automatically reset when the output
returns to a normal state. An LED indicates an overcurrent fault.
All the channels on the DO-4xx modules feature LEDs that
indicate the output state of each channel. The modules all feature an
all channel update rate of 20 kHz. Overall data throughput depends
on software loop speeds and network speeds.
IsolationThe DO-4xx modules feature optical bank isolation with 2,300 Vrmsof breakdown isolation. These Compact FieldPoint and FieldPoint
modules do not have channel-to-channel isolation.
Digital Output Modules forCompact FieldPoint and FieldPoint
8 or 16 digital outputs
5 VDC 12 VDC 24 VDC
Fused outputs for short circuitprotection (DO-410)
2,300 Vrms bank isolation for transientovervoltage protection
Hot swappable with autoconfiguration -40 to 70 C operating range
NI [c]FP-DO-400, NI [c]FP-DO-401,NI [c]FP-DO-403, NI [c]FP-DO-410
NEW
Output Current Rating Electronically All Channel
Module Output Channels Output Ranges (see Specifications for More Details) Compatibility Examples Fused Outputs Update Rate
[c]FP-DO-400 8 10 to 30 VDC, sourcing 2 A 12 and 24 VDC 20 kHz
[c]FP-DO-401 16 10 to 30 VDC, sourcing 2 A 12 and 24 VDC 20 kHz
[c]FP-DO-403 16 5 to 30 VDC, sinking 2 A 5, 12, and 24 VDC 20 kHz
[c]FP-DO-410 8 5 to 30 VDC, sourcing 1 A 5, 12, and 24 VDC 20 kHz
7/30/2019 Compact Fp Mair It At
11/19
Field I/O ConnectionsThe Compact FieldPoint and FieldPoint modules include a built-in
power distribution bus that provides multiple power connections on the
module. A field-wired power supply connected to the voltage (V) and
common (C) terminals is internally connected to a power distributionbus that provides additional breakout terminals for voltage supply
(VSUP) and common (COM). These terminals provide a convenient way
to distribute power to field devices that require external power.
The DO-400 and DO-410 each have:
8 digital output terminals (VOUT)
16 common terminals (COM)
8 power connections to power field devices (VSUP)
The DO-401 and DO-403 each have:
16 digital output terminals (VOUT)
8 common terminals (COM)
8 power connections to power field devices (VSUP)
Digital Output Modules forCompact FieldPoint and FieldPoint
2 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 [email protected] ni.com
To next channel
[c]FP-DO-403
+
VOUT (Ch 0)
VSUP (Ch 0)
V C
VSUP (Ch 0)
COM (Ch 0)
Load
VSUP (Ch 1)
COM (Ch 1)
Load
VSUP (Ch n)
COM (Ch n)
Load
5 30 VDCExternal
Power Supply(Optional)
OutputCircuitry
Output
Circuitry
Output
Circuitry
Output
Circuitry
VOUT (Ch n)
VSUP (Ch n)
VOUT (Ch 1)
VSUP (Ch 1)
Figure 1. Wiring Schematics for DO Modules
Compact FieldPointNI cFP-DO-400 ..........................................................777318-400NI cFP-DO-401 ..........................................................777318-401NI cFP-DO-403 ..........................................................777318-403NI cFP-DO-410 ..........................................................777318-410
Recommended Compact FieldPoint System ProductsNI cFP-2020 ..............................................................777317-2020NI cFP-BP-4 ..................................................................778617-04NI cFP-CB-1..................................................................778618-01NI PS-4 Power Supply ..................................................778805-90NI Developer Suite Professional Control Edition..........777906-03
FieldPointNI FP-DO-400 ............................................................777518-400NI FP-DO-401 ............................................................777518-401NI FP-DO-403 ............................................................777518-403NI FP-DO-410 ............................................................777518-410
Recommended FieldPoint System ProductsNI FP-1601 ....................................................................777792-01
NI FP-TB-1....................... .............................................777519-01NI PS-4 Power Supply ..................................................778586-90NI Developer Suite Standard Control Edition ............777905-03
BUY ONLINE!Visitni.com/infoand enter cfpdo400, cfpdo401, cfpdo403, cfpdo410,fpdo400, fpdo401, fpdo403, and/or fpdo410.
Ordering Information
To next channel
[c]FP-DO-400/401/410
+
COM (Ch 0)
VOUT (Ch 0)
V C
VSUP (Ch 0)
COM (Ch 0)
Load
COM (Ch 1)
VSUP (Ch 1)
COM (Ch 1)
Load
COM (Ch n)
VSUP (Ch n)
COM (Ch n)
Load
530 VDCExternal
Power Supply
VOUT (Ch 1)
VOUT (Ch n)
OutputCircuitry
OutputCircuitryOutput
Circuitry
OutputCircuitry
7/30/2019 Compact Fp Mair It At
12/19
Compact FieldPoint LabVIEW Real-Time Controllers with Ethernet
Overview
National Instruments Compact FieldPoint is a programmable automation
controller (PAC) designed for industrial control applications performing
advanced embedded control, data logging, and network connectivity.
It combines the packaging, specifications, and reliability of a PLC
with the software, flexibility, connectivity, and functionality of a PC.
Compact FieldPoint is a reliable platform designed for rugged industrialenvironments with shock, vibration, and temperature extremes.
National Instruments cFP-21xx controllers run LabVIEW Real-Time,
providing the functionality, connectivity, and flexibility of
National Instruments LabVIEW software on a small industrial platform.
The modular I/O architecture with built-in signal conditioning and
isolation provides direct connectivity to industrial sensors such as analog
voltage, 4 to 20 mA current, thermocouples, RTDs, pressure, strain, flow,
pulse-width modulation (PWM), and 24 V digital I/O. You can use
NI cFP-21xx controllers in intelligent distributed applications requiring
industrial-grade reliability such as process and discrete control
systems to open and close valves, run control loops, log data on a
centralized or local level, perform real-time simulation and analysis, and
communicate over serial and Ethernet networks.
System Basics
A single cFP-21xx controller manages a bank of up to eight
Compact FieldPoint I/O modules. The controller mounts securely on
a metal backplane that provides the communication bus as well as a
solid surface for the Compact FieldPoint I/O modules and controller.
The system is modular; select the I/O modules and connector blocks
or cabling options best suited for your application. Compact FieldPointI/O banks have a number of features for industrial operation, including
2,300 V transient overvoltage protection, a wide temperature range for
operation in extreme environments, backup power supply connections
to protect against primary power failure, and hot-swappable modules
to simplify maintenance and minimize downtime. cFP-21xx controllers
feature an industrial 188 MHz x86 processor that reliably and
deterministically executes your LabVIEW Real-Time applications.
Choose from thousands of built-in LabVIEW functions to build your
multithreaded embedded system for real-time control, analysis, data
logging, and communication. cFP-21xx controllers also offer up to
128 MB of 100 MHz SDRAM and 128 MB of internal nonvolatile storage
and a removable CompactFlash slot. All cFP-21xx controllers feature a
10/100 Mb/s Ethernet port for communication over the network (including
e-mail) and built-in Web (HTTP) and file servers (FTP). Using the LabVIEW
Remote Panel feature, you can automatically publish the front panel
graphical user interface (GUI) for your embedded application so that
multiple clients can monitor or control it remotely using a Web browser.
Rugged LabVIEW Real-Time controller
188 MHz processor andup to 128 MB of SDRAM
Up to 128 MB of nonvolatile storageand 512 MB removable CompactFlash
Ethernet communication for distributedreal-time systems
Dual redundant 11 to 30 VDC powersupply inputs, low power
Up to 4 serial ports (3 RS232 and1 RS485) for communication
Industrial certifications, Class I, Div 2,and -40 to 70 C
Operating Systems Windows 2000/NT/XP
LabVIEW Real-Time
Recommended Software LabVIEW
LabVIEW Real-Time Module
LabVIEW Datalogging andSupervisory Control Module
Driver Software (included) Measurement & Automation Explorer
OPC server (2.0 compliant)
NI cFP-21xx NEW!
Controller SDRAM Memory (MB) Internal Nonvolatile Storage (MB) Removable CompactFlash Ethernet Ports RS232 Ports RS485 Ports
cFP-2120 128 128 1 3 1
cFP-2110 128 64 1 2 0
cFP-2100 64 64 1 1 0
7/30/2019 Compact Fp Mair It At
13/19
CompactFieldPointR
eal-Time
EthernetControllerI
nterfaces
IndustrialControlandD
istributedI/O
Overview and ApplicationsCompact FieldPoint is a programmable automation controller (PAC)
designed for industrial control applications performing advanced
embedded control, data logging, headless operation, and Ethernet
connectivit y. It combines the packaging, specifications, and
reliabili ty of a PLC with the software, flexibil ity, connectivity, and
functionali ty of a PC. Compact FieldPoint is our most rugged and
reliable platform and is designed for industrial and mobile
environments with high shock,vibration, and temperature extremes.
Compact FieldPoint banks run LabVIEW Real-Time, providing the
functionality, connectivity, and flexibility of LabVIEW on a small,
rugged, industrial platform. The modular I/O architecture with
built-in signal conditioning and isolation provides directconnectivity to industrial sensors such as analog voltage, 4 to 20 mA
current, thermocouple, RTD, pressure, strain, flow, pulse width
modulation (PWM), and 24 V digital I /O.
Engineers and scientists use the National Instruments cFP-20xx
controllers in intelligent distributed applications requiring
industrial-grade reliabili ty, such as process and discrete control
systems, to open and close valves, run control loops, log data,
perform real-time simulation and analysis, and communicate over
serial, phone, and Ethernet.
SystemConfigurationsA single NI cFP-20xx controller manages a bank of up to eig
Compact FieldPoint analog and digital I /O modules, whic
consti tutes a node. The network module securely mounts on
metal backplane that provides a solid mounting surface for t
Compact FieldPoint bank and forms the communication b
between the controller module and the I/O modules.You choose t
I/O modules and connector block or cabling option that is be
suited for your application.
For more de tails on c onfiguring a Compact FieldPoint system,
see page 517.
Highly Productive SoftwareWhen your application requires powerful functionality and rap
development, the key is flexible software that integrates seamless
with hardware. LabVIEW is an i ndustr y-standard graphic
development environment that provides all the tools necessary create advanced and full-featured measurement and contr
applications. LabVIEW makes it easy to construct simple
complex applications using an extensive palette of functions an
tools from simple analog PID process control loops to hig
channel-count hybrid control systems that combine both analo
and digital components.
Controller Overview Real- time LabVIEW embeddedcontrollers for intelligentindustrial I/O
Stand-alone embedded real-timecontroller or PC-based distributedI/O Ethernet interface
Industrial-grade reliabili ty Automatic self-diagnostics Redundant power supply inputs Isolated communication bus toI/O modules
RS-232 and RS-485 serialports for local device control
Removable CompactFlashfor data logging
Class I Div 2 Ratedfor Hazardous Environments
Operating Systems Windows 2000/NT/XP Real-time performancewith LabVIEW (page 134)
Recommended Software LabVIEW LabVIEW Real-Time Module LabVIEW Datalogging andSupervisory Control Module
Other Compatible Software LabWindows/CVI Measurement Studio Lookout VI Logger
Driver Software (included) Measurement &Automation Explorer
OPC server (2.0 compliant)
NI cFP-2020, NI cFP-2010, NI cFP-2000
LabVIEW Real-TimeController Interfaces withEthernet
N EW
Internal
DRAM Nonvolite Removable RS-232 RS-485
Module Memory Storage Compact Flash Ethernet Ports Serial Ports Serial Ports
cFP-2020 32 M B 64 M B 1 3 1
cFP-2010 3 2 M B 64 M B 1 2 0
cFP-2000 1 6 M B 32 M B 1 1 0
7/30/2019 Compact Fp Mair It At
14/19
Overview and Distributed Applications
National Instruments cFP-180x interfaces connect four or eight
Compact FieldPoint I/O modules to a high-speed Ethernet network or to
an RS232 serial port. With up to 100 Mb/s data communication rates and
event-driven communications, an NI cFP-180x delivers a high-performance
network connection for Compact FieldPoint that is easy to interface with
a PC or PAC-like Compact FieldPoint embedded controller. One or more
cFP-180x interfaces, connected by standard networking equipment, provide
expanded I/O that you can control with a single Compact FieldPoint
controller, see Figure 1. You can also build a PC-based distributed I/O and
control system by connecting two or more cFP-180x devices to your PC.
Hardware Architecture
A cFP-180x provides an integrated network interface (Ethernet or serial)
and a 4 or 8-slot backplane, and it works with the same modules and
connector blocks used in other Compact FieldPoint systems.
Building Ethernet-BasedDistributed I/O Systems
A cFP-180x can communicate with Compact FieldPoint real-time
embedded controllers; any Ethernet-based programmable automation
controller (PAC); and a Windows computer running LabVIEW,
LabWindows/CVI, Measurement Studio, Lookout, or your choice of OPC
client application software. Using a cFP-180x, you can rapidly build
flexible, modular distributed measurement and automation systems.
Ethernet/Serial Interfaces for Compact FieldPoint
Distributed I/O interfaces for Ethernet
and RS232 networks
4 or 8-slot Compact FieldPoint distributed
Ethernet/serial network interfaces
FieldPoint software for rapid distributed
I/O access
Modbus Support
OPC server included
Intelligent diagnostics and maintenance
Industrial specifications for
harsh environments 50 g shock
5 g vibration
-40 to 70 C
Operating Systems Windows 2000/XP
Recommended Software LabVIEW
LabVIEW Datalogging and Supervisory
Control Module
Other Compatible Software LabWindows/CVI
Measurement Studio
Lookout
VI Logger
Driver Software (included) Measurement & Automation Explorer
OPC server (2.0 compliant)
NI cFP-180x
Compact FieldPoint
Real-Time Controller
NI cFP-1808 Distributed
Network Interfaces
Ethernet
Figure 1. Expansion I/O for Compact FieldPoint Embedded Controller with cFP-1808
Network Interfaces
Figure 2. cFP-1808 Mechanical Dimensions
127 mm(5.00 in.)
441 mm(17.36 in.)
Figure 3. cFP-1804 Mechanical Dimensions
127.0 mm(5.00 in.)
245.9 mm (9.68 in.)
7/30/2019 Compact Fp Mair It At
15/19
Compact FieldPoint AccessoriesCompactFlashThe NI cFP-2020 features a slot for removable CompactFlash solid-state nonvolatile
memory for storing your downloaded application or for performing embedded data
logging.NI offers four sizes of CompactFlash cart ridges, ranging from 64 to 512 MB,
which are industr ially rated to withstand temperatures of -40 to 85 C.
64 MB CompactFlash ......................................................................................778622-64
128 MB CompactFlash ..................................................................................778622-128
256 MB Compact Flash ................................................................................778622-256
512 MB CompactFlash ..................................................................................778622-512
RS-232 CablesThe cFP-20xx controllers have the built-in ability to connect to and control external
serial devices such as LCD/keypad displays, touch screens, PLCs, bar code scanners,
scales, and external I /O. For the RS-232 connector on the front of all cFP-20xx
modules,you can use either a standard DB-9 serial cable or, for applications with tightclearances, the right-angle serial connector. The cFP-2010 and cFP-2020 have
additional serial ports on the side of the module with RJ-50 connectors.These RS-232
and RS-485 ports can use either a cable with an RJ-50 connector on one end and a
DB-9 on the other, or an RJ-50 connection to DIN-rail-mounted connector block
with the CB-485A.
Ethernet CablesTwisted-pair, category 5 cable for 10BaseT and 100BaseTX connection connects the
FieldPoint FP-1601 and FP-20xx network interface modules to an Ethernet switch or hub.
1 m ....................................................................................................................182219-01
5 m ....................................................................................................................182219-05
10 m ..................................................................................................................182219-10
Figure 12. Industrial Rated CompactFlash
Serial Cable Cable Length (m) Connector 1 Connector 2 Applicable Terminals Part Number
Right -Angle Serial Cable 1 Right Angle DB-9 DB-9 Front RS-232 189284-02
S8 Serial Cable 1 RJ-50 DB-9 Side RS-232/ RS-485 182845-01
S8 Serial Cable 2 RJ-50 DB-9 Side RS-232/ RS-485 182845-02
S8 Serial Cable 3 RJ-50 DB-9 Side RS-232/ RS-485 182845-03
S9 Serial Cable 1 RJ-50 DB-25 Side RS-232/ RS-485 182846-01
CB-485A 1 RJ-50 Screw terminals, DIN rai l mount Side RS-232/ RS-485 778674-01
7/30/2019 Compact Fp Mair It At
16/19
CompactFieldPointBa
ckplanes
IndustrialControlandD
istributedI/O
OverviewNational Instruments offers two backplanes for mounting Compact
FieldPoint modules the cFP-BP-4 (4 slots) and the cFP-BP-8
(8 slots). Both backplanes, which are constructed of extruded metal
with grounding lugs on the bottom, feature screw-down connections
for a controller module, four or eight I /O modules, and 37 pin D-Sub
connectors for I /O connections. The backplanes all come with a
cFP-PM-H horizontal mounting bracket, which provides mounting
holes on either side of the backplane so you can mount it to a panel.
For other mounting options, you can purchase a vertical panel
mount, a DIN rail mount, or a 19 in. rack mount separately.
Compact FieldPoint and FieldPointThese backplanes are used with Compact FieldPoint only. Compa
FieldPoint is designed for industrial control applications that perfor
advanced embedded control, data logging, headless operation, an
Ethernet connectivity. Compact FieldPoint is our most rugged a
reliable platform and is designed for industrial and mob
environments with high shock, vibration, and temperature extreme
FieldPoint is a lower-cost distributed I/O system with a variety
communication options besides Ethernet. It is designed to mount o
DIN rails in static applications where the FieldPoint bank is connect
to a PC for data collection, analysis,display, and storage.
4 and 8-slot backplanes Solid metal construction for ruggedinstallations
Panel, DIN rail, and 19 in. rackmounting
Local bus for communicationsand module power
Secure screw mounting for I/Oand control modules
-25 to 60 C operating range
NI cFP-BP-4, NI cFP-BP-8
Compact FieldPoint Backplanes
N EW
Back Plane I/OModule Slots Standard Mounting Hardware
cFP-BP-4 4 cFP-PM -H horizontal panel mount ing bracket
cFP-BP-8 8 cFP-PM -H horizontal panel mount ing bracket
Figure 1. Dimensions of the Compact FieldPoint systems with the cFP-BP-4 and cFP-BP-8 backplanes.
CablingClearance
Cooling Outline51 mm (2 in.)All Around
4 slots =246 mm (9.68 in.)
8 slots =441 mm (17.4 in.)
127mm
(5.0
0in.)
Min.
165mm
(6.5
0in.)
CablingClearance
4 slots =246 mm (9.68 in.)8 slots =441 mm (17.4 in.)
Cooling Outline51 mm (2 in.)
Cooling Outline51 mm (2 in.)
Min.
182mm(7.1
8in.)
106mm(4.1
8in.)
7/30/2019 Compact Fp Mair It At
17/19
Compact FieldPoint BackplanesHigh Shock and VibrationTo withstand high levels of shock and vibration, Compact FieldPoint
backplanes are made of extruded metal and provide a rigid
mounting surface for the Compact FieldPoint modules. The
backplane also provides screw-down connections for the controller
module, I/O modules, and connector blocks.
MountingNI offers four mounting options for Compact FieldPoint
backplanes including panel mounting, DIN-rail mounting, and
19 in. rack mounting.
Compact FieldPoint SystemConfigurationCompact FieldPoint I/O modules mount on either the cFP-BP-4 or
cFP-BP-8 backplane. The backplane also contains a control ler
module, which runs embedded LabVIEW Real-Time and can
connect over Ethernet to a PC, to other FieldPoint banks, to Web
browsers, or to other Ethernet devices. The Compact FieldPoint
backplane also provides a 37-pin D-Sub connector to connect your
field signal wir ing for each I/O module. You have three options to
connect f ield wiring to this 37-pin D-Sub connector:
1. Using an integrated connector block such as the cFP-CB-1
or cFP-CB-11;
2.Using a cable to an external connector block mounted on a DIN rail;
3. Making your own custom cable.
For more details on configuring your Compact FieldPoint system,please see 517.
Number Needed to Number Needed to
Mounting Option Description Mount cFP-BP-4 Mount cFP-BP-8
cFP-PM -H Panel mount w ith bolt holes at 1 1
the sides of the backplane.
(included with all backplane)
cFP-PM -V Panel mount w ith bolt holes at the 1 1
top and bottom of the backplane
cFP-RM -8 19 in. rack mount . Features capt ive 1 1
screws for easy mounting and
cutouts for running grounding cables
DIN rai l DIN rai l cl ip for cFP-BP-4 1 2*
mounting clip
* DIN rail mounting is not recommended for the cFP-BP-8NI cFP-BP-4 ..................................................................778617-04NI cFP-BP-8 ..................................................................778617-08
Recommended Compact FieldPoint SystemProductsNI cFP-2020 ..............................................................777317-2020NI cFP-CB-1..................................................................778618-01NI PS-5 Power Supply ..................................................778805-90NI Developer Suite Professional Control Edition..........777906-03
BUY ONLINE!Visitni.com/infoand enter cfppb4, and/or cfppb8.
Ordering Information
7/30/2019 Compact Fp Mair It At
18/19
CompactFieldPointI/OConnectivityAccessories
IndustrialControlandD
istributedI/O
Flexible I/O ConnectivityThe Compact FieldPoint backplane provides standard 37-pin D-Sub connectors f
the signals from the I/O modules. This provides you the flexibil ity to choose t
connectivity method that works best for your application. You have three options
connect field wiring to the 37-pin D-Sub connectors:
1. Using an integrated connector block like the cFP-CB-1, cFP-CB-3, or cFP-CB-11
2. Using a cable to an external connector block mounted on a DIN rail
3. Making your own custom cable.
Integrated Connector BlocksThe most secure and compact connectivity option is to use the integrate
connector blocks. We offer three connector blocks the cFP-CB-1, the cFP-CB-
and the cFP-CB-11.
cFP-CB-1(See Figure 1)The cFP-CB-1 is a general-purpose connector block suitable for any I/O modu
With 36 terminals, the connector block simpl ifies wir ing by eliminating the need
connect more than one wire to a terminal. The cFP-CB-1 also features both a built-
strain relief bar and a separate wire tie connector, making it easy to create secu
wir ing setups for high shock and vibration applications. Although both th
cFP-CB-1 and the cFP-CB-3 feature a built-in thermistor for cold-junctio
compensation, we recommend using the cFP-CB-3 when measuring thermocouple
cFP-CB-3(See Figure 2)The cFP-CB-3 connector block is designed for use with the cFP-TC-120 module.T
cFP-CB-3 uses isothermal construction to minimize thermal gradients on the I/
terminals. This increases the accuracy of the thermistor that is used for cold-junctio
compensation. The cFP-CB-3 also features both a buil t-in strain relief bar and
separate wire tie connector, making it easy to create secure wir ing setups for hi
shock and vibration applications.
cFP-CB-11(See Figure 3)The cFP-CB-11 is a low-profile, general-purpose connector block suitable for any I/
module except the thermocouple module. These connector blocks feature a side ex
for the wir ing, making them a good fit for applications with limited front clearanc
Because the connector blocks are smaller, the cFP-CB-11 is best suited f
applications that use small-gauge wire or that use only a few channels.
CompactFieldPointI/O Connectivity Accessories
Figure 3. cFP-CB-11 Low-Profile Connector Block
Figure 2. cFP-CB-3 Isothermal Connecto r Block f or
Thermocouple M easurement
Figure 1. cFP-CB-1 General-Purpose Connector Block
Connector Number of High Shock Voltage
Block Screw Terminals Built-in CJC and Vibration Limit Applications Part Number
cFP-CB-1 36 250 V General purpose 778618-01
cFP-CB-3 18 250 V Isothermal 778618-03
for thermocouple
cFP-CB-11 37 24 V Low w iring density 778618-11
and low clearance
7/30/2019 Compact Fp Mair It At
19/19
Compact FieldPoint Accessories
Mounting Options (see figures 1, 2, and 3)NI offers four mounting options for Compact FieldPoint, including panel mounting, DIN rail mounting, and 19 in. rack mounting.
Power Supplies (see Figure 4)National Instruments offers five DC supplies for Compact FieldPoint systems. You connect the power supply output to the Compact FieldPoint
controller, which regulates, filters, and distributes power to the bank of up to eight I/O modules that it controls. All five power supplies can power an
entire bank of Compact FieldPoint I/O modules. The PS-5 mounts on a DIN rail and is recommended for most Compact FieldPoint installations.
Stand-Alone Controller-Mounting Accessories (see Figure 5)National Instruments offers options for mounting stand-alone Compact FieldPoint controllers. These accessories support applications for redundant
controllers without redundant I/O. The panel and DIN rail-mounting kits also provide mounting options for a stand-alone Compact FieldPoint real-time
controller running LabVIEW Real-Time software. Controller-mounting options include panel and DIN rail-mounting.
Figure 1. cFP-PM-V,
Vertical-Mounting Kit
Figure 2. cFP-PM-H,
Horizontal-Mounting Kit
Figure 3. cFP-RM-8,
Rack-Mounting Kit
Figure 4. PS-5 Power
Supply (24 VDC)
Figure 5. Panel and
DIN Rail-Mounting Kits
Mounting Option Description Quantity Needed to Mount cFP-BP-4 Quantity Needed to Mount cFP-BP-8 Part Number
cFP-PM-H Panel mount with bolt holes at the sides of
the backplane (included with all backplane)
1 1 778616-01
cFP-PM-V Panel mount with bolt holes at the
top and bottom of the backplane
1 1 778688-01
cFP-RM-8 19 in. rack mount; features captive screws for easy
mounting and cutouts for running grounding cables
1 1 778615-01
DIN Rail-Mounting Clip DIN rail clip for cFP-BP-4 1 21 778614-01
1DIN rail mounting is not recommended for the cFP-BP-8.
Model Output Voltage (VDC) Output Current (A) Input Voltage Part Number
PS-1 20 0.8 120 VDC 777567-01
PS-2 24 0.8 P = 1 U.S. 120/Japan 100 VAC
2 Swiss 220 VAC, 3 Australian
4 Universal Euro 240 VAC
5 North American 240 VAC
6 United Kingdom 240 VAC
777584-0P
PS-3 13.8 4 Same as PS-2 777585-0P
PS-4 24 0.625 90 to 260 VAC 50/60 Hz 778586-90
PS-5 24 5 90 to 260 VAC 50/60 Hz 778805-90
Power connects to the cFP-21xx modules, which regulate, filter, and distribute to attached I/O modules.
Model Description Part Number
Panel Panel-mounting kit for stand-alone controllers 779549-01
DIN rail DIN rail-mounting kit for stand-alone controllers 779552-01
BUY NOW!
For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/compactfieldpoint.