Upload
vanxuyen
View
213
Download
1
Embed Size (px)
Citation preview
C:\Users\evan\AppData\Local\Temp\000771_ABEC182.docx
C:\Users\evan\AppData\Local\Temp\000771_ABEC182.docx
Our Ref: 17-06/L000771DSC Ref: CA1594/2016Date: 23 May 2017
Chief Executive OfficerCairns Regional CouncilPO Box 359CAIRNS QLD 4870
Dear Sir,
RE: REQUEST UNDER SECTION 369 OF SPA FOR PERMISSIBLE CHANGE TO EXISTING APPROVALFOR RECONFIGURING A LOT AND MATERIAL CHANGE OF USE (MULTI-UNIT HOUSING) AT 24MUDLO STREET, PORT DOUGLAS, MORE PARTICULARLY DESCRIBED AS LOT 60 ON PTD20911
We confirm that Planning Plus Pty Ltd act on behalf of ND Verri (‘the Applicant’) in relation to theabove-described matter. We note that this application is being made under Section 369 on theSustainable Planning Act 2009 to facilitate ‘permissible’ changes to the above-described developmentapproval.
The applicant will pay the relevant assessment fee under Council’s 2016/17 Fee Schedule, being$917.85, direct to Council via credit card.
1.0 BACKGROUND
The subject development approval was issued on 23 November 2016 (copy included as Attachment1). Since receipt of the approval, the applicant has taken the project to the market and feedbackreceived to date indicates a concern about the lack of undercover car parking. To this end, theapplicant is seeking changes to the proposal to introduce a roof structure over the parking area ofeach dwelling.
2.0 PROPOSED CHANGES
The following revised drawings are included for reference as Attachment 2:
Site Plan – Sheet 0 Floor Plans – Sheet 3 Elevations – Sheet 4 Area Plan Site Cover – Sheet 5 Street-View Renders.
C:\Users\evan\AppData\Local\Temp\000771_ABEC182.docx
As noted above, this submission seeks changes to the proposal to include a roof structure over theproposed parking areas for each dwelling. This change has come about following market feedbackthat the lack of undercover car parking is a concern.
The applicant’s concern following receipt of this feedback is that not only will this issue hamper theability to sell the product, but that should the product still sell, that buyers may attempt to introducetheir own ad-hoc shade structures. Some of these structures may not require council approval andcould result in a sub-optimal outcome for the development.
The issue is further compounded by the presence of bats in the area which would further drive theneed for covered car spaces on this particular site.
Taking the above into account, the applicant is proposing a high-quality, visually appealing concreteroof structure, embellished with vine-type vegetation. As is evidenced by the Street View Renders,the change blends in seamlessly with the existing approved built form and continues to achieve ahighly appropriate streetscape aesthetic.
3.0 LEGISLATIVE CONSIDERATIONS
3.1 Sustainable Planning Act 2009
This section provides an overview of the legislative context of the application under the provisions ofthe Sustainable Planning Act 2009.
3.1.1 Permissible Change
We submit that the proposed changes are ‘permissible’ for the purpose of the Sustainable PlanningAct 2009 in that they do not contravene the requirements of Section 367. In particular, we note thefollowing with respect to Section 367:
a. The revised proposal does not result in a ‘substantially different development’.b. (i) The revised proposal does not trigger additional referral agencies.
(ii) The revised proposal does not trigger ‘impact assessable’ development where nonepreviously existed.
c. The previous application did not require impact-assessment.d. The revised proposal does not introduce prohibited development.
3.1.2 Assessment Manager
The Assessment Manager for this development application is Douglas Shire Council as determined bySchedule 6 of the Sustainable Planning Regulation 2009.
3.2 Douglas Shire Planning Scheme
It is noted that the proposed change results in an increase in site cover by approximately 8%, up fromapproximately 52% to approximately 60%. While this figures exceeds the Douglas Shire Council‘acceptable solution’ of 45% (under the Tourist and Residential Planning Area Code), it is consideredto remain compliant with the corresponding ‘performance criteria’ which states:
“The Site Coverage of all Buildings, other than a House, does not result in a built form that is bulky orvisually obtrusive.”
C:\Users\evan\AppData\Local\Temp\000771_ABEC182.docx
We submit that the proposed additional roof structure does not create a bulky or visually obtrusivebuilt form, but rather blends in well with the existing approved built form, as discussed above.
It is further noted that the proposal is only 2 storeys in height, whereas 3 storeys is permitted on thesubject site. The omission of a third level is considered to provide some leeway in terms of site coverwhen determining overall building bulk.
4.0 CONCLUSION
This submission supports an application by ND Verri (‘the applicant’) for a Permissible Change to anexisting approval for Reconfiguring a Lot and Material Change of Use (Multi-Unit Housing) over landlocated at 24 Mudlo Street, Port Douglas, more particularly described as Lot 60 on PTD20911.
In summary, we submit that the proposed changes are considered ‘permissible’ for the purpose of theSustainable Planning Act 2009 and are unlikely to result in any unacceptable adverse impacts on thesurrounding community or environment.
We trust this information is sufficient for your purposes, however should you require any furtherdetails or clarification please do not hesitate to contact the undersigned.
Yours Faithfully
Evan YelavichSenior PlannerPlanning Plus Pty Ltd
enc: Attachment 1: Decision NoticeAttachment 2: Revised Plans
@ AT
ACCORD. ACCORDING
AS AUSTRALIAN STANDARD CODES
NCC NATIONAL CONSTRUCTION CODEBC HONED / BURNISHED CONCRETE FINISH
CMB CONCRETE MASONRY BLOCK
CONC CONCRETE
COS CONFIRM ON SITECRS CENTRES
CS CAVITY SLIDER
CSK COUNTERSUNK
CT COOK TOPCTFP CORTEN FENCE PANEL
CFW CONTINUOUS FILLET WELD
DIA. DIAMETER
DPC DAMP PROOF COURSEDW DISHWASTER
D.P DOWN PIPE
EA EQUAL ANGLE
EJ EXPANSION JOINTFC FIBRE-CEMENT
FFL FINISHED FLOOR LEVEL
FH FLAT HEAD NAILS
g GUAGE (BOLTS, SCREWS)GAL GALVANISING
HH HEAD HEIGHT
HEX. HEXAGONAL HEAD (BOLT)
HR SELECT GLASS BALUSTRADE & HANDRAIL
HT HEIGHTHWD HARDWOOD
HWS HOT WATER SYSTEM
LOSP LIGHT ORGANIC SOLVENT PRESERVATIVE
MM MILLIMETRESMANUF. MANUFACTURER
MAX. MAXIMUM
MIN. MINIMUM
MGP MACHINE GRADED PINEMIC MICROWAVE OVEN
MS MILD STEEL
NGL NATURAL GROUND LEVEL
OFC OFF-FORM CONCRETE FINISHOG OBSCURE GLASS
PB PLASTERBOARD LINING
PF SELECT 1200H POOL FENCE
PL PLATEPVC POLYVINYL CHLORIDE
REINF REINFORCING
RGH ROUGHER HEADER H3 TREATED PINE
RHS RECTANGULAR HOLLOW SECTIONSCJ SAW CUT JOINT
SFL STRUCTURAL FLOOR LEVEL
SHS SQUARE HOLLOW SECTION
SLC SELECT HWD SHIPLAP CLADDINGSS STAINLESS STEEL
SPEC SPECIFICATION
SHS SQUARE HOLLOW SECTION
TOW TOP OF WALL
UA UNEQUAL ANGLEUNO UNLESS NOTED OTHERWISE
L01 LINTEL NUMBER
D01 DOOR NUMBER
W01 WINDOW NUMBER
SECTION MARKER
ELEVATION KEY
DETAIL CALLOUT
ROOM NAME CEILING HEIGHT
CEILING MATERIAL
FLOOR FINISH
REDUCED LEVEL
SLAB SETDOWN
SLAB FALL
SLAB THICKNESS
+ 00.000 SPOT LEVEL
SECTION REFERENCE
SHEET REFERENCE
A04
03 N
RL 00.000
100
FALL .
01
04
DETAILREFERENCE
SHEETREFERENCE
100
SHEET REFERENCE
VIEW DIRECTION
2800PB
CT
LOUNGE
LEGENDULTIMATE & SERVICEABILITY LIMIT STATE DESIGN WIND PRESSURES
DESIGN GUST
WIND SPEED(m/s)
WINDCLASS
DESIGN PRESSURES(kPa)
GREATER THAN1.2m FROM CORNERS
UP TO1.2m FROM CORNERS
ULS SLS ULS SLS
C2 61 39 ±2.68 ±0.88 -4.02 -1.23
V h,u V h,s
ULS SLS
VILLA 3
LOT 3
337.24m²
B E R Y L
50292
01 01
02 02
C
C
D
D
B
B
A
A
VILLA 2
LOT 2
337.24m²
VILLA 1
LOT 1
337.24m²
16764 16764 16764
2011
7
S T R E E T
MH
2011
7
EXIS
TIN
G S
EWER
- D
EPTH
TO
BE
CO
S
VILLA 1 VILLA 2 VILLA 2 VILLA 3
VILLA 1 VILLA 2 VILLA 2 VILLA 3
VILLA 1
VILLA 1
VILLA 3
VILLA 3
M
U
D
L
OS
T
R
E
E
T
50.292 m90° 00' 00"
20.1
17 m
0° 0
0' 0
0"
50.292 m270° 00' 00"
20.1
17 m
180°
00'
00"
EXISTING STREET TREES TO REMAIN
EXISTING K & C
EXIS
TIN
G F
OO
TPAT
H T
O R
EMAI
N
EXISTING K & C
EXIS
TIN
G K
& C
EXIS
TIN
G K
& C
1200 WIDE FOOTPATHS AS
PER FNQROC GUIDELINES
DRIVEWAY CROSSINGS AS
PER FNQROC GUIDELINES
0000
0/S
P12
9232
59/PTD20911
CURRENTLY LOT 60 / PTD20911
1011.72m²
1° 1° 1°
EXISTING ERGON PILLAR
E
NEW ERGON PILLAR
E
EXISTING ERGON PILLAR
E
COS
1600
BATTER LANDSCAPING
BACK TO NEW FOOTPATH
LANDSCAPED GARDENS - REFER LANDSCAPERS DRAWINGSLANDSCAPED GARDENS - REFER LANDSCAPERS DRAWINGS LANDSCAPED GARDENS - REFER LANDSCAPERS DRAWINGS
LAN
DSC
APED
GAR
DEN
S - R
EFER
LAN
DSC
APER
S D
RAW
ING
SLA
ND
SCAP
ED G
ARD
ENS
- REF
ER L
AND
SCAP
ERS
DR
AWIN
GS
POOL
CONC ROOF
CONC ROOF CONC ROOF
CONC ROOF
CONC ROOF CONC ROOF
CONC ROOF
CONC ROOF CONC ROOF
1400
FAS
CIA
4174
5527
FAS
CIA
655 FASCIA 4174 FASCIA 655 FASCIA 4174 FASCIA 655 FASCIA
5527
FAS
CIA
1400
FAS
CIA
POOL POOL
TERMITE TREATMENT:
- ALL TIMBER USED IN PROJECT TO BE EITHER NATURALLY
RESISTANT TO TERMITE ATTACK (AS LISTED IN AS3660.1-APPENDIX C) OR CHEMICALLY TREATED TIMBERS IN
ACCORDANCE WITH AS3660.1-APPENDIX D.
- LOSP TREATED TIMBER TO BE TREATED TO H2 LEVEL FOR ALL
TIMBERS USED IN ABOVE GROUND, DRY, WEATHER PROTECTED AREAS, SUCH AS TRUSSES, WALL FRAMING AND SUB-FLOOR
APPLICATIONS.
- H3 LEVEL APPLICATIONS TO BE ABOVE GROUND, OUTSIDE,
EXPOSED TO WEATHER AREAS SUCH AS DECKING, FENCE PICKETS & RAILS, PERGOLAS, EXPOSED FLOOR JOISTS AND
BEARERS AND EXTERNAL WALL CLADDINGS. DUE TO THE DYE
PIGMENT CONTAINED IN LOSP TREATED TIMBERS, ALL INTERNAL
ARCHITRAVES AND MOULDINGS TO BE EITHER NATURALLY RESISTANT TIMBERS OR H3 LEVEL LOSP TREATED TIMBERS.
- ALL SLAB PENETRATIONS TO HAVE TERMIMESH MARINE GRADE
STEEL COLLARS FITTED BY MANUFACTURER'S QUALIFIED
TECHNICIANS.
CONCRETE MASONRY NOTES:
GENERAL WALLS U.N.O- 190 SERIES CONC MASONRY BLOCKS IN ACCORDANCE WITH AS 3700 & AS 2733.
MORTAR 1:1:6 (C:L:S) DOTS DENOTE N12 VERTICAL BARS (U.N.O.) AT ENDS, CORNERS,
INTERSECTIONS, EACH SIDE OF ALL OPENINGS AND AT CRS NOTED ON PLANS.
LAP VERTICAL BARS 600mm WITH N12 STARTER BARS COGGED 200mm INTO FOOTING
PROVIDE ADDITIONAL N12 VERTICAL BAR EACH SIDE OF OPENINGS >1800 WIDE. - PROVIDE DOUBLE COURSE (U.N.O.) CONTINUOUS BOND BEAM TO TOP OF 190 SERIES
WALLS. REINF. WITH 1-N12 BAR EACH COURSE - LAP 800mm MIN.
- ALL EXTERNAL JOINTS TO BE 'FLUSHED' LEFT READY FOR RENDERING.
- ALL CMB WALLS THAT ARE TO BE CONCRETE FILLED ARE TO BE WATER HOSED DURING THE WALL CONSTRUCTION TO REMOVE MORTAR DAGS IN THE MASONRY CORES.
CONCRETE STRENGTH:
- ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH AS3600. - N20 GRADE CONCRETE TO ALL FOOTINGS
- N32 GRADE CONCRETE TO SLABS
- CONCRETE
- CONCRETE GENERALLY IN ACCORDANCE WITH AS 3600
- CONCRETE SPECIFICATION UNLESS NOTED OTHERWISE:
ELEMENT CLASS & GRADE MAX. AGG. MAX. SLUMP
GROUND SLAB N32 20mm 80mm
FOOTINGS N20 20mm 80mmCORE FILL S20 10mm 230mm
REINFORCEMENT NOTATION:
'N' DENOTES GRADE D500N HOT ROLLED REBAR TO AS4671.'S' DENOTES GRADE D250N HOT ROLLED REBAR TO AS4671.
'R' DENOTED GRADE R500L COLD DRAWN ROUND WIRE TO AS4671.
'W' DENOTES GRADE R500L COLD DRAWN ROUND WIRE TO AS4671.
'DW' DENOTES GRADE D500L COLD DRAWN RIBBED WIRE TO AS4671.
'RL', 'SL', 'L_TM' DENOTES FRAYED D500 DEFORMED WIRE MESHES TO AS4671.- ADDITIVES SHALL NOT BE USED WITHOUT THE SUPERINTENDENT'S APPROVAL.
- MECHANICALLY VIBRATE CONCRETE IN THE FORM TO GIVE MAXIMUM COMPACTION
WITHOUT SEGREGATION OF THE CONCRETE.
- CURE CONCRETE AS REQUIRED BY SECTION 19 OF AS3600.- CONCRETE SIZES SHOWN ARE MINIMUM AND DO NOT INCLUDE APPLIED FINISHES.
- DO NOT REDUCE OR HOLE CONCRETE WITHOUT SUPERINTENDENT'S APPROVAL.
- DO NOT PLACE CONDUITS, PIPES AND THE LIKE WITHIN THE COVER CONCRETE.
- FORMWORK SHALL GENERALLY COMPLY WITH AS3610- STRIPPING OF FORMWORK SHALL COMPLY WITH SECTION 19 OF AS3600.
SITE PREPARATION:
- STRIP BUILDING SITE OF ALL TOPSOIL AND ORGANICS.- BUILDING PLATFORM AND PAVEMENT SUPPORT AREAS SHOULD BE UNIFORMLY
COMPACTED BY HEAVY SURFACE ROLLING TO A MINIMUM DRY DENSITY RATIO OF
95% SRDD. SOFT SPOTS ENCOUNTED DURING COMPACTION TO BE TREATED BY
TYNING, DRYING AND RECOMPACTION. - THE USE OF VIBRATORY ROLLERS FOR EARTHWORKS COMPACTION MAY CAUSE
SIGNIFICANT GROUND VIBRATION AND CAREFUL SITE CONTROL OR THE USE
HEAVY STATIC COMPACTION PLANT WILL BE REQUIRED TO AVOID DAMAGE TO
ADJOINING MASONRY BUILDINGS. - ALL FILL MATERIAL TO BE OF LOW PLASTICITY (P1<15) GRANULAR SELECT FILL,
PLACED IN LAYERS NOT MORE THAN 200mm COMPACTED THICKNESS, AND
UNIFORMLY COMPACTED TO A MINIMUM DRY DENSITY RATION OF 95% SRDD.
- BUILDER TO SURVEY SITE PRIOR TO COMMENCEMENT OF EARTHWORKS AND
CONSTRUCT BUILDING PLATFORM TO A LEVEL SUCH THAT ALL SURFACE WATER IS DIRECTED AWAY FROM THE BUILDING
TO A SATISFACTORY DRAINAGE OUTLET.
- BUILDER SHALL ENSURE THAT SUITABLE AND APPROPRIATE VEHICULAR ACCESS
IS PROVIDED TO THE BUILDING. - BUILDER SHALL ENSURE THAT SUITABLE SOIL EROSION BARRIERS ARE
INSTALLED COMPLYING WITH EPA AND LOCAL AUTHORITY REQUIREMNETS.
- REFER TO SOIL TEST CLASSIFICATION CARRIED OUT BY
DIRT PROFESSIONALS - REPORT No. 18457 DATE: 16.12.2016- SITE TO BE RE TESTED AFTER ROLLER COMPACTION FOLLOWED BY ENGINEER
CONSULTATION AND POSSIBLE ENGINEERING AMENDMENTS DEPENDANT
WET AREA WALLS:
- ALL WET AREA WALLS AND FLOORS TO BE WATERPROOFED WITH
APPROVED MEMBRANES IN ACCORDANCE WITH AS/NZS 4858. - WET AREAS TO BE WATERPROOFED IN ACCORDANCE WITH NCC 2016
PART 3.8.1.2.
- WALL/FLOOR COVERINGS: BUILDER TO CONSULT OWNER FOR FULL
EXTENT OF FLOOR COVERING REQUIREMENTS.
- SELECTED WALL TILES TO WET AREAS AND SPLASHBACKS. PROVIDE APPROVED ADHESIVE TO ALL TILES.
STEELWORK:
- ALL STEEL WORKS TO BE CARRIED OUT TO AUSTRALIAN
STANDARDS 4100 STEEL STRUCTURES CODE- STEEL SHALL BE AS 3679 & 3678 GENERALLY
GRADE 300 PLUS FOR HOT ROLLED SECTIONS
AS 1163 GRADE 350 FOR HOLLOW SECTIONS
- BOLTS SHALL BE COMMERCIAL GRADE 4.6/S SNUG TIGHTENED GENERALLY U.N.O.
- BOLTS SHALL BE GALVANISED OR & OF SUFFICENT
LENGTH TO EXCLUDE THE THREAD FROM THE SHEAR PLANE
A SUITABLE WASHER SHALL BE USED UNDER ALL NUTS UNLESS
OTHERWISE SPECIFIED - THE FOLLOWING TO APPLY
BEAM AND BEARER SPLICE TO BE FPBW TO AS 1554.1 CLASS SP
WELDING 6MM CONTINUOUS FILLET WELD TO FULL PERIMETER
AT CONTACT- CLEATS, BRACKETS, STIFFENERS ETC. TO BE 10mm PLATE
5PL END PL TO ALL HOLLOW SECTIONS
- BOLT HOLE CLEARANCE TO BE 2mm
- HOLD DOWN BOLT CLEARANCE 2mm
- GROUT OF 2:1 CEMENT/SAND, MORTAR OF DAMP EARTH CONSISTENCY UNDER ALL BASE PLATES
- CHEMSET ANCHORS TO BE RAMSET SPIN CAPSULES OR SERIES
800 OR EQUILVALENT
- ALL STEEL WORK NOT HOT DIPPED GALVANISED SHALL BE ABRASIVE CLEANED TO CLASS 2.5 LEVEL & PAINTED
- PAINTING SHALL CONSIST OF ONE COAT OF APPROVED METAL
PRIMER & TWO FINISH COATS
- ALL CAST IN ITEMS TO BE HOT DIPPED GALVANIZED U.N.O
GENERAL
- ALL WORKS SHALL BE IN STRICT ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA 2016 AND AMENDMENTS,
AS1684.3-2010 RESIDENTIAL TIMBER FRAMED CONSTRUCTION PART 3
AND AMENDMENTS.
- ALL RELEVANT STANDARDS, LOCAL AUTHORITY BY-LAWS AND
REGULATIONS AND WORKPLACE HEALTH & SAFETY REGULATIONS.
ACCREDITED BUILDING PRODUCTS REGISTER AND MANUFACTURERS
CURRENT WRITTEN SPECIFICATIONS AND RECOMMENDATIONS. BUILDER TO VERIFY ALL DIMENSIONS AND LEVELS
ON SITE BEFORE COMMENCING ANY
SITE WORKS OR WORKSHOP DRAWINGS.
- DO NOT SCALE DRAWINGS - TAKE FIGURED DIMENSIONS.
- SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY WILL
VOID VARIATION TO ANY PART OF THE DESIGN & ANY RESPONSIBILITIES
OF THE BUILDING DESIGNER FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING.
AIR CONDITIONING:
- BUILDER TO NOTE THAT SPLIT AIR CONDITIONING UNITS TO
BE INSTALLED WHERE REQUIRED BY OWNER OR AS PER PLAN ONLY . ALLOWANCE TO BE MADE FOR THE
INSTALLATION OF GAS PIPES AND CONDENSATION DRAINS
AT TIME OF POURING SLAB AND ERECTING WALLS.
- ALL PIPES TO BE INSULATED AS REQUIRED.
- INSTALLATION TO BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION.
SERVICE LOADS:
- THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED FOR THE FOLLOWING LIVE LOADS UNLESS NOTED OTHERWISE: 0.25 kPa ROOF 1.50 kPa
INTERNAL SUSPENDED FLOORS 3.00 kPa EXTERNAL SUSPENDED FLOORS 1.50 kPa
GROUND FLOORS LIVE LOADS TO AS 1170 PART 1 REGION C. DESIGN GUST WIND
SPEED 50m/s PERMISSIBLE, 61/m ULTIMATE LIMIT STATE
PLUMBING:
- ALL SHOWER ROSES TO BE 3 STAR (WELS) RATED IN
ACCORDANCE WITH AS/NZS 6400:2004: 4 STAR WATER EFFICENCY LABELING AND STANDARDS (WELS)
SCHEME RATED CISTERNS WILL BE INSTALLED TO ALL
WATER CLOSETS PREVIOUSLY 3-STAR WELS RATED.
- MINIMUM 3-STAR WELS RATED TAP WARE WILL BE INSTALLED TO ALL KITCHEN SINKS, BATHROOM BASINS
AND LAUNDRY TROUGHS.
- PLUMBER TO PROVIDE FORM 16 COMPLIANCE
CERTIFICATE FOR ALL ABOVE ITEMS - REFER TO WASTEWATER CONSULTANTS - DISPOSAL
ASSESSMENT REPORT WC20647 DATE 12.03.2012
ELECTRICAL:
- A MINIMUM 80% OF THE TOTAL FIXED
INTERNAL LIGHTING WILL BE FITTED WITH ENERGY EFFICIENT LIGHTING AS DEFINED
BY QDC PART MP 4.1 (MIN. 27 LUMENS PER
WATT). IF AIR CONDITIONERS ARE BEING
INSTALLED THEY WILL HAVE A MINIMUM 4-STAR MINIMUM ENERGY PERFORMANCE
STANDARD (MEPS) RATING. ELECTRICIAN TO
PROVIDE FORM 16 CERTIFICATE FOR ALL
ABOVE ITEMS HAVE BEEN COMPLIED WITH. PROVIDE ADDITIONAL DOCUMENTATION FROM
LIGHT MANUFACTURER CONFIRMING THE
LIGHT FITTINGS ACHIEVE THE MINIMUM 27
LUMENS PER WATT.
FOOTINGS & SLABS :
- FOOTINGS HAVE BEEN DESIGNED FOR A MINIMUM ALLOWABLE BEARINGPRESSURE OF 100KPA & CLASS 'P' SITE CLASSIFICATION ACCORDING TO A.S.
2870
- BUILDER TO VERIFY SITE CONDITIONS PRIOR TO CONSTRUCTION
- NATURAL FOUNDATIONS TO BE GRUBBED OUT & FREE OF ORGANIC MATTER & DEBRIS & COMPACTED TO A MIN. 95% SRDD AT -5% TO +2% OF OPTIMUM
MOISTURE CONTENT OR NOT LESS THAN 70% DENSITY INDEXED FOR
COHESIONLESS SOILS.
- FILL TO SLAB TO & FOUNDATIONS SHALL BE APPROVED NON-PLASTIC MATERIAL COMPACTED IN MIN 150mm LAYERS TO 95% SRDD AT -5% TO +2% OF THE
OPTIMUM MOISTURE CONTENT OR NOT LESS THAN 70% SRDD FOR
COHESIONLESS SOILS.
- FOOTING TRENCHES SHALL BE CLEAN & DRY AT THE TIME OF CASTING WITH ANY SOFTENED MATERIAL REMOVED.BASE OF FOOTING TO BE FOUNDED ON
FIRM NATURAL GROUND WITH MINIMUM SAFE BEARING CAPACITY OF 100KPA.
- REMOVE GRASS & TOPSOIL CONTAINING ROOTS FROM SLAB SITE PROVIDE
COMPACTED SAND BEDDING UNDER SLAB.- PROVIDE 0.2mm POLYTHENE MOISTURE BARRIER UNDER SLAB & FOOTINGS
- CONCRETE TO SLAB & FOOTINGS TO BE N20, 80mm SLUMP, 20mm AGGREGATE
- VIBRATE ALL CONCRETE, CURE SLAB 7 DAYS MINIMUM.
- CONCRETE COVER TO BE MAINTAINED BY THE USE OF APPROVED BAR CHAIRS SPACED AT APPROX 750mm CRS.
- CONDUITS& PIPES SHALL NOT BE PLACED WITHIN COVER CONCRETE
- LAP SLAB MESH 2 CROSSWIRES MINIMUM LAPS UNLESS OTHERWISE
NOTED:- N12 - 600mm, N16 - 800mm, N20 - 1000mm, N24 - 1200mm, N28 - 1400mm. REINFORCEMENT COVER: FOOTINGS - 50mm BOTTOM ,SLABS - 40mm TOP / 50mm
BOTTOM
- CAST-IN ITEMS SHALL BE HOT DIPPED GALVANISED
- FOOTINGS SHALL NOT BE LOCATED CLOSER TO THE NEAREST EDGE OF A SORMWATER/SEWER TRENCH THAN THE DEPTH OF THE TRENCH.
WALL CONSTRUCTION - FRAMING:
INTERNAL STUDWORK WALLS
70MM THICK WALLS :
-MGP10 (H2)
- 70 x 35 STUDS @MAX. 600MM CRS.
- 70 x 35 TOP & BOTTOM PLATES - 1 ROW NOGGINS.
90MM THICK WALLS :
-MGP12 (H2)- 90 x 35 STUDS @MAX. 450MM CRS.
- 90 x 35 TOP & BOTTOM PLATES - 1 ROW NOGGINS.
- 90 x 45 TOP & BOTTOM PLATES TO BRACE WALLS.
ROOF FRAMING :
TRUSSES
- PREFABRICATED ROOF TRUSSES DESIGNED BY THE TRUSS MANUFACTURER INCLUDING ALL NECESSARY BRACING AND CONNECTIONS.
- J2 JOINT GROUP FOR HWD TRUSSES.
- JD4 JOINT GROUP FOR PINE TRUSSES.
ROOF BRACING
- METAL STRAP BRACING TO TRUSS MANUFACTURER'S DESIGN.
ROOF SHEET & BATTEN FIXINGS
- LYSAGHT SHEETING OVER LYSAGHT BATTENS
- ALL ROOF SHEETING AND BATTEN FIXINGS ARE TO BE IN ACCORDANCE WITH
THE MANUFACTURERS SPECIFICATION FOR THE REQUIRED WIND SPEED.- THE FIXING SYSTEMS FOR THE WHOLE METAL ROOF ASSEMBLY SUPPLIED
BY THE MANUFACTURER, ARE TO BE COMPLIANT WITH THE LOW-HIGH-LOW
CYCLIC TESTING REQUIREMENTS OF THE BUILDING CODE OF AUSTRALIA
(SPECIFICATION B1.2 VOLUME 1 FOR CLASS 2 TO 9 BUILDINGS) OR (SECTION 3.10.1 VOLUME 2 FOR CLASS 1 & 10 BUILDINGS).
- A 'COMPLIANCE CERTIFICATE' SHALL BE REQUESTED FROM THE
'MANUFACTURER' & THE 'INSTALLER'
GENERAL :
- LAPS, FLASHINGS AND GENERAL INSTALLATION IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATION.
- BUILDER TO PROVIDE 2 DURABLE NOTICES PERMANENTLY
FIXED IN PROMINENT LOCATIONS, SUCH AS THE ELECTRICITY METER BOX AND A KITCHEN CUPBOARD. THE NOTICE TO
INDICATE:
- METHOD OF PROTECTION. - DATE OF INSTALLATION OF THE SYSTEM USED.
- WHERE A CHEMICAL BARRIER IS USED, ITS LIFE EXPECTANCY
AS LISTED ON THE NATIONAL REGISTRATION AUTHORITY LABEL.
- THE INSTALLER'S OR MANUFACTURER'S RECOMMENDATIONS FOR THE SCOPE AND FREQUENCY OF FUTURE INSPECTIONS
FOR TERMITE ACTIVITY.
- THE BUILDER MAY PROVIDE AN ALTERNATIVE TERMITE
TREATMENT SYSTEM PROVIDE SUCH SYSTEMIS CERTIFIED WITH THE AUSTRALIAN BUILDING CODES BOARD AS REQUIRED BY THE
NCC 2016.
- GENERALLY, THE TERMITE TREATMENT SHALL COMPLY WITH
NCC 2016 PART 3.1.3
- SITE AREA TO BE GRADED TO READILY REMOVE SURFACE WATER & PREVENT
PONDING ADJACENT TO FOUNDATIONS & DRIVEWAY.
- EXECUTION & CONTROL TESTING OF EARTHWORKS & ASSOCIATED SITE PREPARATION WORKS SHALL COMPLY WITH A.S. 3798
DESIGNER DRAWN SCALEISO A1
SHEET REV
SHEET
PROJECT PROJECT ADDRESS
PROJECT NUMBER
© NATHAN VERRI QBCC LIC NO. 1111288w : nathanverri.com e : [email protected] Box 1334 Mossman Q 4873
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
AS SHOWN @ A1REVISION
22-May-17 11:48:00 AMNV GL
MUDLO VILLAS
PROPOSED SITE PLAN, GENERAL NOTES & LEGEND
24MDLST 00
LOT 60 / PTD20911
24 MUDLO STREET
PORT DOUGLAS Q 4877
M U D L O S T R E E T V I L L A S
DRAWING REGISTER
SHEET TITLE REV
00 PROPOSED SITE PLAN, GENERAL NOTES & LEGEND
01 SITE PLAN - EXISTING / DEMOLITION
02 PROPOSED SITE AMENITIES & TEMPORARY FENCING
03 FLOOR PLANS - TYPICAL VILLA LAYOUT
04 ELEVATIONS
05 SECTIONS
06 SITE FOOTINGS PLAN
07 SITE SLAB SET-OUT
08 LOWER SLAB / WALL REINFORCEMENT PLANS
09 TYPICAL VILLA UPPER SLAB PLANS
10 ROOF FRAMING / LINTEL PLANS & DETAILS
11 ELECTRICAL LAYOUTS
12 HYDRAULIC SERVICES - SITE PLAN & NOTES
13 HYDRAULIC SERVICES - SANITARY DRAINAGE /STORMWATER & WATER PLANS
1 : 100
SITE PLAN - PROPOSEDSITE PLAN - PROPOSEDSITE PLAN - PROPOSEDSITE PLAN - PROPOSED
L O T 6 0 / P T D 2 0 9 1 1 - 2 4 M U D L O S T R E E T P O R T D O U G L A S Q 4 8 7 7
ULTIMATE & SERVICEABILITY LIMIT STATE DESIGN WIND PRESSURES
DESIGN GUSTWIND SPEED
(m/s)
WINDCLASS
DESIGN PRESSURES(kPa)
GREATER THAN1.2m FROM CORNERS
UP TO1.2m FROM CORNERS
ULS SLS ULS SLS
C2 61 39 ±2.68 ±0.88 -4.02 -1.23
V h,u V h,s
ULS SLS
A
05
B
05
GARAGE2850OFCBC
DINING2750OFCBC
SERVICE COURT2700OFCBC
PWDR2750OFCBC
LAUNDRY2750OFCBC
ENSUITE 12750OFCBC
BEDROOM 12750OFCBC
POOL TERRACE2800OFCBC
POOL
SUN PAD
GATEHOUSE2700OFC
LANDSCAPED
KITCHEN2750OFCBC
ENTRY2750OFCBC
LOUNGE2750OFCBC
D03
D10
D06 D05
W03W04
D11
W02
D04
D09
D08
D02
D07
PLANTER
WC
HWU
CL
POOL PLANT
HEAT PUMP
NICHE1200 SILL,300H X 100D
OUTDOOR KITCHEN
REF UNDER
CPDS
WMDRY
SEAT
& W
ATER
FALL
STEPS
UP
ROBE
NO
OK
TV / ENT UNIT
ISLA
ND
PTY
CO
OKT
OP
/ R'H
OO
D
INTE
GR
ATED
R
EF
DW
O'H
EAD
CPD
S
BI-FOLD PLANTATION
SHUTTERS 2750H C/W RECESSED HEAD TRACK
DRIVEWAY
AUTO GATE
GARDEN COURTYARD
VB
TUB
BBQ SK
SK
O'H
EAD
CPD
S
SER
VIC
ES
SLIDING HORIZONTAL
TIMBER GATES
4.900
SFL 4.900
SFL 5.000
GAR
DEN
BED
GAR
DEN
BED
GARDEN BED
GAR
DEN
BED
GARDEN BED
VBWC
SHR
MXRG
ARD
EN B
ED
FRAMELESS GLASSPOOL FENCE &SELECT FITTINGS
4.950
WATER & GAS METERS
GATE MOTOR
WOMW
ZIP TAP
BEACH SHOWER
C
05
EPD02
50 W
P
EPD0
1
ST02
ST01
DP100
DP100
DP100
BC
AC BULKHEAD OVER ROBE / DOOR
AC BULKHEAD OVER
AC SLOT
AC SLOT
AC
AC AC S
LOT
AC
AC S
LOT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
01 01
02 02
B
B
A
A
E
05
DG
AHU
DP100
AC
D01
W01
VILLA 1 VILLA 2
VILLA 1 VILLA 2
VILLA 1
VILLA 1
PRO
PER
TY
BO
UN
DA
RY
PRO
PER
TY
BO
UN
DA
RY
PELM
ET
150W X 100H RECESSED CURTAIN PELMET IN SLAB SOFFIT
DEPTH 1.4
M +
DEPTH 2.0M +
300 YARD PIT
300 YARD PIT
300 YARD PIT
300 YARD PIT
PROPERTY BOUNDARY
PROPERTY BOUNDARY
01
03
LPG
ORG
REFER CABINET MAKERS
DRAWINGS FOR JOINERY DETAILS UNO
MXR
MXR
DOOR UNDER
POOL COPING TO BE FLUSH
WITH POOL TERRACE FLOOR
4.950
CTFP CTFP CTFP CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
CTFP
SLIDING
CTFP
CTF
PGATE
GAT
E
GAT
EG
ATE
PFPF
PF
LANDSCAPE PAVERS,
REFER LANDSCAPERS DWGS
150 CMB WALL
150 CMB WALL
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS, 10 PB INTERNALLY,CEMENT RENDER EXTERNALLY UNO
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS, 10 PB INTERNALLY,CEMENT RENDER EXTERNALLY UNO
70 X 35 MGP10 STUDFRAMING @ 600 MAX CRSTO INTERIOR WALLS UNO.10PB GENERALLY, 6MMVILLA TO WET AREAS
SLC
SLC
SLCSLC
SELECT SHIPLAP
HWD CLADDING,REFER DETAIL
200 CMB WALLS& CEMENTRENDER FINISH
SLC
SS WATER BLADE &
LED STRIP LIGHT TO WATERFALL
CORTEN PANELLED STEEL FRAMED
ELECTRIC GATE C/W REMOTE CONTROL
150W X 35H RECESSED SHUTTER
HEAD TRACK
GARDEN BED
GAR
DEN
BED
BULKHEAD OVER TO
EXTENTS OF BENCH
200 CMB PIERS
SHEL
F
LINE OF FLOOR OVER
LINE OF FLOOR OVER
NOTE : POOL TO
VILLAS 2 & 3 VARY.
REFER SLAB SET-OUT PLAN
BC
SUN PAD
OFCBC
2650
D15
D14
D13
A
05
B
05BEDROOM 2
2700PBBC
ENSUITE 22700PBBC
BEDROOM 32700PBBC
BEDROOM 42700PBBC
BALCONY2700PBBC
ENSUITE 32700PBBC
ENSUITE 42700PBBC
RUMPUS2700PBBC
PWDR 22700PBBC
WIR2700PBBC
D19
D20
W08
W09
W07
W10
W05
W06
W13
D12
D16
D18
W11
W12
W14
PLANTER
PLAN
TER
PLAN
TER
PLAN
TER
NICHE
NICHE
DN
KITC
HEN
ETTE
REF
SH
CPD
SK
TYP SHR NICHE
1200 SILL,300H X 100D
SHRMXR
TWL TRH
WC
TRH
WC TWL
SCREEN
BT
SPOUT
MXR
MXR
TRH
WC
SHR
RAIL
SHR
TWL
FEATURE BLADE WALL FINISH TBC
TV / ENT UNIT
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
VB
SHR
SCREEN
D
05
AC
AC SLOTIN CEILING
MXR
DP100 CONCEALED
IN WALL
DP100 CONCEALED
IN WALL
PLANTER DRAIN
PLANTER
DRAIN
150 CMB WALL
150 CMB WALL
150 CMB WALL
150 CMB WALL
150 CMB WALL
HR HR
HRHR
2 x 2750HSLIDING
SHUTTERS
AC BULKHEAD OVER
AC S
LOT
AC SLOT
AC S
LOT
HR
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
200 CMB PLANTER
WALLS @ 400H TYP TO UPPER FLOOR
90 X 35 STUD WALL &
CONCEALED SHS COLUMN
WC
VB
HR
5 6 7 8 9 10 11 12 13 14 15 16 17
01
02
B
B
E
05
D17
D21
D22
VILLA 1 VILLA 2
VILLA 1 VILLA 2
PROPERTY BOUNDARY
MW
AC
AC
AC B
ULK
HEA
D O
VER
AC B
ULK
HEA
D O
VER
02
03
PELMET
PELMET
PELMET
PELM
ET
150 X 150 FRAMED & PB LINED
RECESSED CURTAIN PELMETS WITHIN CEILING CAVITY TYP
NICHE
NOTE :
AIRONDITIONG BULKHEADS TO BE FRAMED & PB
LINED NOM. 700W X 340D.PROVIDE REMOVABLE DURABLE ACCESS PANEL
TO EACH BULKHEAD UNIT UNO
CONC ROOF CONC ROOF
01
02
BA
D03
D10
D06
D05
W03W04
D11
W02
D04
D09
D08
D02
D07
GARAGE2850OFCBC
DINING2750OFCBC
SERVICE COURT
PWDR2750OFCBC
LAUNDRY2750OFCBC
ENSUITE 12750OFCBC
BEDROOM 12750OFCBC
POOL TERRACE2800OFCBC
POOL
SUN PAD
GATEHOUSE2700OFC
LANDSCAPED
KITCHEN2750OFCBC
ENTRY2750OFCBC
LOUNGE2750OFCBC
W01
D01
2011
7
3727
2400
9890
2000
2100
190
2210
190
5810
190
3510
190
1810
190
1910
190
3200
1910
700
16764
4374 2300 7190 1100 1800
390 810 1290 1710 1990 3110 190 910 190 1010 600 190
3750 140 3300
1910 70 1130 70 1030
4374 4290
190 4184 3600
190 500
2011
7
2100
3790
1050
037
27
6127
4100
2990
6710
800
190
3410
190
1910
190
190
2800
1010
7017
3060
0
290 210 190
100
620 70 3810 70 1130 70 1030
7019
3070
425
8790
3810 700 3400
4510 190 3210 190
7974 460 1340 70
190 7784 190 200 70
7043
30
7974 2890 5900
16764
190 1610 190 900 1310 1390 2810 390
190 3210 190 3210 190
1800 190 6800
1300
390
4437
190 10 190
01
02
B
D15
D14
D13
D19
D20
D12
D16
D18 D17
D21D22
W08
W09
W07
W10
W05
W06
W13
W11
W12
W14
BEDROOM 22700PBBC
BEDROOM 32700PBBC
BEDROOM 42700PBBC
ENSUITE 32700PBBC
ENSUITE 42700PBBC
RUMPUS2700PBBC
PWDR 22700PBBC
ENSUITE 22700PBBC
WIR2700PBBC
13190
2900 7390 2200 700
1000 2500 3390 5000 800
815 610 955 610 400 4110 890 610 190
190 2310 190 3010 190 4810 190
190 2710 190 7010 190 2010 190 510 190
2011
7
5527
1049
026
0015
00
190
1011
019
024
1019
013
1019
0
5600
3190
3700
800
1300
190
610
190
3510
190
2810
190
290
3690
1810
200
200
3590
5790
7028
1014
035
60
1220
590
610
3470
2400
590
610
6590
170
2205
7016
6570
330
7081
5
1565
7031
90
140 1610 70
7029
8014
0
70 1910 70 1150 70
5527
1459
0
8300
4790
1500
190
4410
190
1310
190
1300
800
4190
4670
3630
390
4280
190
3810
190
1030
7018
10
820 70 930
550 760 600
1080
70
140
3280
1000
7012
070
2096
580 1740 140 1030
600 590
70
160 90 3490
660 3740 3350 3350 1490
140 3600 140 3210 140 3210 190 1110 190
110
1000 1980 1000 900
930 70 1980 70 930
12590
3700 3090 5800
5410 390
600
4927
CONC ROOF CONC ROOF
100
220
19 35 190
SECRET FIX SELECT
HWD SHIPLAP HORIZONTAL CLADDING
C/W MITRED CORNERS
OVER SARKING & 70 X 35
RGH H3 BATTENS @ 600 MAX CRS
ENTRY
SECTION
PLAN
200 CMB WALL
200 CMB WALL
CAPRAL ALUMINIUM 60 X 3 EA
CORNER STOP AT DOOR 10
OPENING & FRONT SERVICES NIB WALL. POWDERCOAT TO
MATCH DOOR JOINERY
DINING
POOL TERRACE
LINE OF SLAB SET DOWN
200 CMB &
PB LINING
460
100 210 190
FRAME SCREEN
VOID AS REQ'D
CENTOR S1 SCREEN
CONCEALED IN VOID
290
D10
LINE OF SLAB
SET DOWNS
150 CMB
PIER
FRAME SCREEN VOID AS REQ'D,
BLUEBOARD LINE & CEMENT RENDER FINISH
CENTOR S1 SCREEN
CONCEALED IN VOID
D12
D13
250
140
390
DOOR / WINDOW NOTES:
- REFER FLOOR PLAN FOR DOOR SWINGS- DOOR HARDWARE, FURNITURE & FINISH AS SELECTED
- GLAZING TO BE SELECT SOLAR REFLECTIVE OR SIMILAR
- ALUMINIUM FRAMES TO BE COLORBOND MONUMENT
POWDERCOAT FINISH UNO
- ALL DIMENSIONS TO BE CONFIRMED ON SITE- JOINERY TO AS2047-1999 FOR WATER PENETRATION &
WIND LOAD REQUIREMENTS
- GLAZING TO AS1288-2006, CERTIFICATE TO BE SUPPLIED
- SEAL ALL ROUND FRAMES. - SECURITY SCREENS WHERE REQUIRED BY OWNER.
- INTERNAL TIMBER DOORS TO BE AS PER SELECTION.
(2340 X 820 U.N.O.) HUNG ON 90 X 19 FJP JAMBS
- POWDERCOAT REMOTE CONTROL PANELIFT DOOR TO GARAGE WITH 3 HANDSETS.
DESIGNER DRAWN SCALEISO A1
SHEET REV
SHEET
PROJECT PROJECT ADDRESS
PROJECT NUMBER
© NATHAN VERRI QBCC LIC NO. 1111288w : nathanverri.com e : [email protected] Box 1334 Mossman Q 4873
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
AS SHOWN @ A1REVISION
22-May-17 11:48:03 AMNV GL
MUDLO VILLAS
FLOOR PLANS - TYPICAL VILLA LAYOUT
24MDLST 03
LOT 60 / PTD20911
24 MUDLO STREET
PORT DOUGLAS Q 4877
1 : 100
FLOOR PLAN - LOWERFLOOR PLAN - LOWERFLOOR PLAN - LOWERFLOOR PLAN - LOWER 1 : 100
FLOOR PLAN - UPPERFLOOR PLAN - UPPERFLOOR PLAN - UPPERFLOOR PLAN - UPPER
SCHEDULE - DOORS
MARK TYPE HEIGHT WIDTH OTHER REQ'S
01 SINGLE LEAF ENTRY DOOR 2750 1310 SELECT FEATURE ENTRY DOOR
02 920 LEAF CAVITY SLIDER 2380 1860 920 X 2340 LEAF
03 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
04 720 LEAF CAVITY SLIDER 2340 1460 720 X 2340 LEAF
05 FX ALUMINIUM SLIDING DOOR 2410 1910 INSECT SCREENS
06 FX ALUMINIUM SLIDING DOOR 2410 1910 INSECT SCREENS
07 820 LEAF CAVITY SLIDER 2380 1660 820 X 2340 LEAF
08 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
09 FXX ALUMINIUM SLIDING DOOR 2800 3410 INSECT SCREENS
10 FXXX ALUMINIUM SLIDING CAVITY DOOR 2750 6710 6710 OPENING / CENTOR S1 SCREENS / FLUSHPULL HANDLES
11 PANEL LIFT GARAGE DOOR REMOTE CONTROL
12 FXX ALUMINIUM SLIDING CAVITY DOOR 2750 3280 3280 OPENING / CENTOR S1 SCREEN / FLUSHPULL HANDLES
13 FXX ALUMINIUM SLIDING DOOR 2710 3490 INSECT SCREENS
14 FXX ALUMINIUM SLIDING DOOR 2720 3210 INSECT SCREENS
15 FXX ALUMINIUM SLIDING DOOR 2710 3210 INSECT SCREENS
16 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
17 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
18 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
19 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
20 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
21 SINGLE LEAF INTERNAL DOOR 2380 870 820 X 2340 LEAF
22 820 LEAF CAVITY SLIDER 2340 1660 820 X 2340 LEAF
SCHEDULE - WINDOWS
MARK WINDOW TYPE HEIGHT WIDTH OTHER REQS
01 2 X BAY ALUMINIUM LOUVRE WINDOW 810 1310
02 1 X BAY ALUMINIUM LOUVRE WINDOW 1810 600 152MM CLEAR GLASS BLADES / CRIMSAFE SCREEN
03 1 X BAY ALUMINIUM LOUVRE WINDOW 1010 910 152MM CLEAR GLASS BLADES / CRIMSAFE SCREEN
04 1 X BAY ALUMINIUM LOUVRE WINDOW 2410 810 152MM CLEAR GLASS BLADES / CRIMSAFE SCREEN
05 1 X BAY ALUMINIUM LOUVRE WINDOW 2410 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
06 1 X BAY ALUMINIUM LOUVRE WINDOW 2410 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
07 5 X BAY ALUMINIUM LOUVRE WINDOW 610 3690 152MM CLEAR GLASS BLADES / INSECT SCREENS
08 1 X BAY ALUMINIUM LOUVRE WINDOW 1210 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
09 1 X BAY ALUMINIUM LOUVRE WINDOW 1210 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
10 3 X BAY ALUMINIUM LOUVRE WINDOW 610 2410 152MM CLEAR GLASS BLADES / INSECT SCREENS
11 5 X BAY ALUMINIUM LOUVRE WINDOW 1810 4110 152MM CLEAR GLASS BLADES / INSECT SCREENS
12 1 X BAY ALUMINIUM LOUVRE WINDOW 1010 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
13 1 X BAY ALUMINIUM LOUVRE WINDOW 1010 610 152MM CLEAR GLASS BLADES / INSECT SCREEN
14 5 X BAY ALUMINIUM LOUVRE WINDOW 1810 3810 152MM CLEAR GLASS BLADES / INSECT SCREENS
VILLA 1 ( VILLAS 2 & 3 SIMILAR ) VILLA 1 ( VILLAS 2 & 3 SIMILAR )
1 : 100
FLOOR PLAN - LOWER DIMENSIONSFLOOR PLAN - LOWER DIMENSIONSFLOOR PLAN - LOWER DIMENSIONSFLOOR PLAN - LOWER DIMENSIONS 1 : 100
FLOOR PLAN - UPPER DIMENSIONSFLOOR PLAN - UPPER DIMENSIONSFLOOR PLAN - UPPER DIMENSIONSFLOOR PLAN - UPPER DIMENSIONS
DETAILDETAILDETAILDETAIL 1 : 10
03
ENTRY WALL SHIPLAP CLADDING
DETAILDETAILDETAILDETAIL 1 : 1003
01
DOOR 10 CLOSING JAMB - LOWER FLOOR
DETAILDETAILDETAILDETAIL 1 : 1003
02
DOOR 12 / 13 CLOSING JAMB - UPPER FLOOR
ULTIMATE & SERVICEABILITY LIMIT STATE DESIGN WIND PRESSURES
DESIGN GUST
WIND SPEED(m/s)
WINDCLASS
DESIGN PRESSURES(kPa)
GREATER THAN1.2m FROM CORNERS
UP TO1.2m FROM CORNERS
ULS SLS ULS SLS
C2 61 39 ±2.68 ±0.88 -4.02 -1.23
V h,u V h,s
ULS SLS
SFL LOWER
5.000
SFL LOWER
5.000
SFL UPPER
8.070
SFL UPPER
8.070
TOW UPPER
10.770
TOW UPPER
10.770
HH UPPER
10.480
HH UPPER
10.480
HH LOWER
7.410
HH LOWER
7.410TOW BOUNDARY
6.750
TOW BOUNDARY
6.750
PROJECT BENCH
4.750
PROJECT BENCH
4.750
FRAMED PARAPET &15MM CFC CLADDING
DP10
0
SELECT ALUMINIUMDOORS & WINDOWS
AUTO GATE
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
CTFP CTFP CTFP CTFP CTFP
GATE
CTFP CTFP CTFP CTFP
TANKED PLANTER
SELECT SHIPLAP
HWD CLADDING
DP10
0
AUTO GATE
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
CTFP CTFP CTFP CTFP CTFP
GATE
CTFP CTFP CTFP CTFP
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
200 CMB WALLS& CEMENTRENDER FINISH
SELECT SHIPLAP
HWD CLADDING
FRAMED PARAPET &15MM CFC CLADDING
DP10
0
SELECT ALUMINIUMDOORS & WINDOWS
AUTO GATE
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
CTFP CTFP CTFP CTFP CTFP
GATE
CTFP CTFP CTFP CTFP
TANKED PLANTER
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
200 CMB WALLS& CEMENTRENDER FINISH
SELECT SHIPLAP
HWD CLADDING
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
200 CMB WALLS& CEMENTRENDER FINISH
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
TANKED PLANTER
PLANT COVERED
CONC ROOF & BLADE COLUMNS
PLANT COVERED CONC ROOF PLANT COVERED CONC ROOF PLANT COVERED CONC ROOF
SFL LOWER
5.000
SFL LOWER
5.000
SFL UPPER
8.070
SFL UPPER
8.070
TOW UPPER
10.770
TOW UPPER
10.770
HH UPPER
10.480
HH UPPER
10.480
HH LOWER
7.410
HH LOWER
7.410TOW BOUNDARY
6.750
TOW BOUNDARY
6.750
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
200 CMB WALLS& CEMENTRENDER FINISH
TANKED PLANTER
200 CMB WALLS& CEMENTRENDER FINISH
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
200 CMB WALLS& CEMENTRENDER FINISH
TANKED PLANTER FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
200 CMB WALLS& CEMENTRENDER FINISH
FRAMED PARAPET &15MM CFC CLADDING
DP10
0
DP10
0
DP10
0
DP10
0
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
TANKED PLANTER
DP10
0
DP10
0
DP10
0
DP10
0
DP10
0
DP10
0
DP10
0
DP10
0
200 CMB WALLS& CEMENTRENDER FINISH
SFL LOWER
5.000
SFL LOWER
5.000
SFL UPPER
8.070
SFL UPPER
8.070
TOW UPPER
10.770
TOW UPPER
10.770
HH UPPER
10.480
HH UPPER
10.480
HH LOWER
7.410
HH LOWER
7.410TOW BOUNDARY
6.750
TOW BOUNDARY
6.750
PROJECT BENCH
4.750
PROJECT BENCH
4.750
200 CMB WALLS& CEMENTRENDER FINISH
COLORBOND KLIPLOK ROOFSHEET, FASCIA, GUTTER &MATCHING FLASHINGS
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
DP10
0
DP10
0
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
CTFP CTFP CTFP CTFP CTFP CTFP CTFP
600
TANKED PLANTER
15MM CFCFASCIA
COLORBOND KLIPLOK ROOFSHEET, FASCIA, GUTTER &MATCHING FLASHINGS
OFF-FORM FINISH TOUPPER SLAB SOFFIT UNO
SELECT SHIPLAP
HWD CLADDING
200 CMB WALLS& CEMENTRENDER FINISH
DP10
0
DP10
0
DP10
0
SLOTTED EMLINE GUTTER
SLOTTED EMLINE GUTTER
200 CMB BLADE
COLUMN
PLANT COVERED CONC ROOF
SFL LOWER
5.000
SFL LOWER
5.000
SFL UPPER
8.070
SFL UPPER
8.070
TOW UPPER
10.770
TOW UPPER
10.770
HH UPPER
10.480
HH UPPER
10.480
HH LOWER
7.410
HH LOWER
7.410TOW BOUNDARY
6.750
TOW BOUNDARY
6.750
200 CMB WALLS& CEMENTRENDER FINISH
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
200 CMB WALLS& CEMENTRENDER FINISH
200 CMB WALLS& CEMENTRENDER FINISH
TANKED PLANTER OFF-FORM FINISH TOUPPER SLAB SOFFIT UNO
SELECT SHIPLAP
HWD CLADDING
FRAMELESS GLASSBALUSTRADE &SELECT FITTINGS
CTFP CTFP CTFP CTFP CTFP CTFP CTFP CTFP
FRAMED PARAPET &15MM CFC CLADDING
DP10
0200 CMB BLADE
COLUMN
PLANT COVERED CONC ROOF
SFL LOWER
5.000
SFL LOWER
5.000
SFL UPPER
8.070
SFL UPPER
8.070
TOW UPPER
10.770
TOW UPPER
10.770
HH UPPER
10.480HH UPPER
10.480
HH LOWER
7.410
HH LOWER
7.410TOW BOUNDARY
6.750
TOW BOUNDARY
6.750
PROJECT BENCH
4.750
PROJECT BENCH
4.750
TANKED PLANTER
SELECT SHIPLAP
HWD CLADDING
CTFP CTFP CTFP CTFP CTFP CTFP CTFP
200 CMB WALLS& CEMENTRENDER FINISH
COLORBOND KLIPLOK ROOFSHEET, FASCIA, GUTTER &MATCHING FLASHINGS
FRAMED PARAPET &15MM CFC CLADDING
OFF-FORM FINISH TOUPPER SLAB SOFFIT UNO
FRAMED PARAPET &15MM CFC CLADDING
SELECT ALUMINIUMDOORS & WINDOWS
200 CMB WALLS& CEMENTRENDER FINISH
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
POOL
200 CMB WATERFALL FRAME &
TANKING MEMBRANEAGAINST REAR WALL OF VILLA
1800
3490 1700
WATERFALL NICHEPOOL PLANT
CORTEN FENCE PANELDETAILS BY FENCINGCONTRACTOR
SLOTTED EMLINE GUTTER
SLOTTED EMLINE GUTTER
190
190
190
SS WATER BLADE & LED
STRIP LIGHT TYP
200 CMB BLADE
COLUMN
PLANT COVERED CONC ROOF
DESIGNER DRAWN SCALEISO A1
SHEET REV
SHEET
PROJECT PROJECT ADDRESS
PROJECT NUMBER
© NATHAN VERRI QBCC LIC NO. 1111288w : nathanverri.com e : [email protected] Box 1334 Mossman Q 4873
PRELIMINARY ISSUE
NOT FOR CONSTRUCTION
AS SHOWN @ A1REVISION
24-May-17 9:04:33 AMNV GL
MUDLO VILLAS
ELEVATIONS
24MDLST 04
LOT 60 / PTD20911
24 MUDLO STREET
PORT DOUGLAS Q 4877
1 : 100
ELEVATION - NORTHELEVATION - NORTHELEVATION - NORTHELEVATION - NORTHN
1 : 100
ELEVATION - SOUTHELEVATION - SOUTHELEVATION - SOUTHELEVATION - SOUTHS
1 : 100
ELEVATION - EASTELEVATION - EASTELEVATION - EASTELEVATION - EASTE
1 : 100
ELEVATION - WESTELEVATION - WESTELEVATION - WESTELEVATION - WESTW
1 : 100
ELEVATION - TYPICAL VILLA 2 & 3 / POOL WATERFALLELEVATION - TYPICAL VILLA 2 & 3 / POOL WATERFALLELEVATION - TYPICAL VILLA 2 & 3 / POOL WATERFALLELEVATION - TYPICAL VILLA 2 & 3 / POOL WATERFALLV
231 m²
UNCOVERED
227 m²
UNCOVERED
227 m²
UNCOVERED
109 m²
SITE COVER
109 m²
SITE COVER
109 m²
SITE COVER
SITE COVER 1ST
SITE COVER228.2m²UNCOVERED
109m²
AV VILLA ALL VILLAS
684.6m²327m²
TOTAL SITE AREA 337.2m² 1011.7m²
% AV VILLA % ALL VILLAS
67.68%32.32%
100% 100%
67.68%32.32%
SITE COVER177.6m²
UNCOVERED 123m²
OPEN CARPORT
ROOF26.6m²
UNCOVERED 10m²
SITE COVER177.6m²
UNCOVERED 123m²
OPEN CARPORT
ROOF26.6m²
UNCOVERED 10m²
SITE COVER177.6m²
UNCOVERED 123m²
OPEN CARPORT
ROOF26.6m²
UNCOVERED 10m²
SITE COVER GROUND
SITE COVER 177.6m²UNCOVERED 133m²
AV VILLA ALL VILLAS
532.9m²399m²
TOTAL SITE AREA 337.2m² 1011.7m²
% AV VILLA % ALL VILLAS
52.66%39.44%
100%
52.66%39.44%
100%
OPEN CARPORT ROOF 26.6m² 79.8m² 7.88% 7.88%
www.nathanverri.com
CLIENT NOTE
COPY RIGHT!!!
NATHAN VERRI PTY
LTD
SHEET
DESIGNED
SHEET NAME:
DATE
STRUCTURAL DETAILSADEQUATE AS CERIFIED
DRAWN BY:
NATHAN
NATHAN
22-May-17 3:04:20 PM
NATHAN VERRI
24 MUDLO ST PORT DOUGLAS
VILLAS ON BERYL
AREA PLAN SITE COVER
SHEET 5
1 : 100
SITE COVER AREA 1ST1
1 : 100
SITE COVER GROUND2