16
1 CLASSROOM 2 ROOM RESOURCE 3 CLASSROOM VESTIBULE JK/SK 4 KINDERGARTEN 5 KINDERGARTEN ROOM NAME 18 6 STAFF ROOM G2 7 CLASSROOM 8 CLASSROOM 9 CLASSROOM 10 CLASSROOM B2 S1 11 12 LIBRARY G1 STORAGE M1 ROOM BOILER 13 CLASSROOM 14 CLASSROOM 15 CLASSROOM S2 G.C.R. GYM STAGE OFFICE TREATMENT 16B NEEDS SPECIAL 16A SPECIAL ED 16C B1 STAFF OFFICE S5 S4 STOR 17 ROOM WORK S3 ISSUED KEY PLAN LEGEND A000 BRIDGEVIEW CLASSROOM RENOVATION AND WINDOW REPLACEMENT 205 ALBERT ST, POINT EDWARD, ON N7V 1R4 COVER PAGE, CONSULTANTS, DRAWING LIST, KEY PLAN MBV MFPU 2011 AS NOTED 2021-02-26 ISSUED FOR OWNER REVIEW 1 2021-03-04 ISSUED FOR TENDER 2 1 KEY PLAN SCALE = 1:200 BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM RENOVATIONS AND WINDOW REPLACEMENT #2021-AL84/89-214 ARCHITECT 17|21 ARCHITECTS INC. 280 QUEENS AVE. SUITE 1Q. LONDON, ONTARIO N6B 1X3 T: (519)439-0611 MECHANICAL AND ELECTRICAL CONSULTANTS CHORLEY & BISSET 369 YORK STREET, SUITE 2B LONDON, ONTARIO N6B 3R4 T: (519) 679-8660 STRUCTURAL CONSULTANT VANBOXMEER & STRANGES ENGINEERING LTD 1108 Dundas St., Suite 104 London, Ontario N5W 3A7 T: (519) 433-4661 ARCHITECTURAL DRAWINGS A000 - COVER PAGE, CONSULTANTS, DRAWING LIST, KEY PLAN D100 - DEMOLITION FLOOR PLAN A100 - FLOOR PLAN, ENLARGED FLOOR PLANS, REFLECTED CEILING PLAN, BUILDING ELEMENTS A300 - BUILDING ELEVATIONS, WINDOW TYPES A500 - WALL SECTIONS, WINDOW DETAILS A800 - INTERIOR ELEVATIONS, DOOR SCHEDULE, ROOM FINISH SCHEDULE, DOOR AND FRAMES TYPES. A900 - MILLWORK DETAILS STRUCTURAL DRAWINGS S-100 - PART ROOF FRAMING PLAN MECHANICAL DRAWINGS M100 - MECHANICAL LEGEND, DRAWING LIST & SCHEDULES M200 - PART FLOOR PLAN PLUMBING M300 - PART FLOOR PLAN HEATING M400 - PART FLOOR PLAN AIR DISTRIBUTION ELECTRICAL DRAWINGS E100 - ELECTRICAL LEGEND, KEYPLAN, ABBREVIATIONS, DRAWING LIST, SCHEDULES, DETAILS, AND NOTES E200 - PART FLOOR PLAN ELECTRICAL NEW AND DEMOLITION 2 WALL TYPES SCALE = 1:20 205 ALBERT ST, POINT EDWARD, ON N7V 1R4

BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

1CLASSROOM

2ROOM

RESOURCE

3CLASSROOM

VESTIBULEJK/SK

4KINDERGARTEN

5KINDERGARTEN

ROOM NAME

18

6STAFF ROOM

G2

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

B2

S111

12LIBRARY

G1

STORAGE

M1ROOM

BOILER

13CLASSROOM

14CLASSROOM

15CLASSROOM

S2

G.C.R.

GYM

STAGE

OFFICETREATMENT

16BNEEDS

SPECIAL

16ASPECIAL ED

16CB1STAFFOFFICE

S5

S4

STOR

17ROOMWORK

S3

ISSUED

KEY PLAN

LEGEND

A000

BRIDGEVIEW CLASSROOM RENOVATIONAND WINDOW REPLACEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

COVER PAGE, CONSULTANTS, DRAWING LIST, KEY PLAN

MBVMFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 KEY PLANSCALE = 1:200

BRIDGEVIEW ELEMENTARY SCHOOLCLASSROOM RENOVATIONS AND WINDOW REPLACEMENT

#2021-AL84/89-214

ARCHITECT

17|21 ARCHITECTS INC.280 QUEENS AVE. SUITE 1Q.LONDON, ONTARION6B 1X3T: (519)439-0611

MECHANICAL AND ELECTRICAL CONSULTANTS

CHORLEY & BISSET369 YORK STREET, SUITE 2BLONDON, ONTARION6B 3R4T: (519) 679-8660

STRUCTURAL CONSULTANT

VANBOXMEER & STRANGES ENGINEERING LTD1108 Dundas St., Suite 104London, OntarioN5W 3A7T: (519) 433-4661

ARCHITECTURAL DRAWINGS

A000 - COVER PAGE, CONSULTANTS, DRAWING LIST, KEY PLAND100 - DEMOLITION FLOOR PLANA100 - FLOOR PLAN, ENLARGED FLOOR PLANS, REFLECTED

CEILING PLAN, BUILDING ELEMENTSA300 - BUILDING ELEVATIONS, WINDOW TYPESA500 - WALL SECTIONS, WINDOW DETAILSA800 - INTERIOR ELEVATIONS, DOOR SCHEDULE, ROOM FINISH

SCHEDULE, DOOR AND FRAMES TYPES.A900 - MILLWORK DETAILS

STRUCTURAL DRAWINGS

S-100 - PART ROOF FRAMING PLAN

MECHANICAL DRAWINGS

M100 - MECHANICAL LEGEND, DRAWING LIST & SCHEDULESM200 - PART FLOOR PLAN PLUMBINGM300 - PART FLOOR PLAN HEATINGM400 - PART FLOOR PLAN AIR DISTRIBUTION

ELECTRICAL DRAWINGS

E100 - ELECTRICAL LEGEND, KEYPLAN, ABBREVIATIONS, DRAWINGLIST, SCHEDULES, DETAILS, AND NOTES

E200 - PART FLOOR PLAN ELECTRICAL NEW AND DEMOLITION

2 WALL TYPESSCALE = 1:20

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

Page 2: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

1CLASSROOM

2ROOM

RESOURCE

3CLASSROOM

VESTIBULEJK/SK

4KINDERGARTEN

5KINDERGARTEN

ROOM NAME

18

6STAFF ROOM

G2

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

B2

S111

12LIBRARY

G1

STORAGE

M1ROOM

BOILER

13CLASSROOM

14CLASSROOM

15CLASSROOM

S2

16BNEEDS

SPECIAL

16ASPECIAL ED

16CB1STAFFOFFICE

S5

S4

STOR

17ROOMWORK

GENERAL NOTES:

DEMOLITION NOTES:

LEGEND:

ISSUED

KEY PLAN

LEGEND

D100

BRIDGEVIEW CLASSROOM RENOVATIONAND WINDOW REPLACEMENT

***

DEMOLITION FLOOR PLAN

MBVMFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 DEMOLITION FLOOR PLANSCALE = 1:125

Page 3: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

1CLASSROOM

2ROOM

RESOURCE

3CLASSROOM

VESTIBULEJK/SK

4KINDERGARTEN

5KINDERGARTEN

ROOM NAME

18

6STAFF ROOM

G2

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

B2

S111

12LIBRARY

G1

STORAGE

M1ROOM

BOILER

13CLASSROOM

14CLASSROOM

15CLASSROOM

16BNEEDS

SPECIAL

16ASPECIAL ED

16CB1STAFFOFFICE

S5

S4

STOR

17ROOMWORK

18AUNIV. WR.

2

A100

CUST

1

A300

2

A300

3

A300

4

A300

3

A100

18

6STAFF ROOM

18AUNIV. WR.

CUST

9CLASSROOM

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

18

6STAFF ROOM

S111

18AUNIV. WR.

CUST

ISSUED

KEY PLAN

LEGEND

A100

BRIDGEVIEW CLASSROOM RENOVATIONAND WINDOW REPLACEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

FLOOR PLAN, ENLARGED FLOOR PLANSREFLECTED CEILING PLAN

MBVMFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 FLOOR PLANSCALE = 1:125

2 ENLARGED FLOOR PLAN - STAFF ROOMSCALE = 1:50

3 ENLARGED FLOOR PLAN - TYPICAL CLASSROOMSCALE = 1:50

4 REFLECTED CEILING PLANSCALE = 1:125

Page 4: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

ISSUED

KEY PLAN

LEGEND

A900

BRIDGEVIEW CLASSROOM RENOVATION AND WINDOW REPLANCEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

MILLWORK DETAILS

MBVMFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 MILLWORK SECTIONSCALE = 1:102 MILLWORK SECTION

SCALE = 1:103 MILLWORK SECTIONSCALE = 1:104 MILLWORK SECTION

SCALE = 1:105 MILLWORK SECTIONSCALE = 1:10

6 MILLWORK SECTIONSCALE = 1:10

Page 5: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

1

A900

2

A900

3

A900

4

A900

1

A900

3

A900

6

A900

5

A900

2

A900

1

A900

1

A900

2

A900

ISSUED

KEY PLAN

LEGEND

A800

BRIDGEVIEW CLASSROOM RENOVATION AND WINDOW REPLANCEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

INTERIOR ELEVATIONSDOOR SCHEDULE, ROOM FINISH SCHEDULEDOOR AND FRAME TYPES

MBVMFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 INTERIOR ELEVATION - STAFF ROOMSCALE = 1:50 2 INTERIOR ELEVATION - STAFF ROOM

SCALE = 1:50

3 TYPICAL CLASSROOMSCALE = 1:50 4 CLASSROOM 09 ELEVATION

SCALE = 1:50 6 TYPICAL CLASSROOM ELEVATIONSCALE = 1:505 CLASSROOM 09 ELEVATION

SCALE = 1:50

10 CUSTODIAN ROOMSCALE = 1:50 11 TYP CLASSROOM MILLWORK

SCALE = 1:50

16 DOOR TYPESSCALE = 1:3015 FRAME TYPE

SCALE = 1:5

12 TYP CLASSROOM MILLWORKSCALE = 1:50

13 TYPICAL CLASSROOM ELEVATIONSCALE = 1:50 14 TYPICAL CLASSROOM ELEVATION

SCALE = 1:50

7 UNIVERSAL WASHROOMSCALE = 1:50 8 UNIVERSAL WASHROOM

SCALE = 1:50 9 UNIVERSAL WASHROOMSCALE = 1:50

Page 6: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

13

A500

12

A500

5

A500

6

A500

8

A500

7

A500

8

A500

9

A500

10

A500

..\..\..\..\Production\17l21 Branding\1721 architects_ Logo Package\11_21 architects_ Logo Package\FOR DIGITAL (MS Office, Social Media, Web...)\17_21 architects_LOGO_RGB.jpg

ISSUED

KEY PLAN

LEGEND

A500

BRIDGEVIEW CLASSROOM RENOVATION AND WINDOW REPLANCEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

WALL SECTIONS, WINDOW DETAILS

MFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

1 TYPICAL UNIT VENTALATOR SECTIONSCALE = 1:202 WINDOW W3 TYP. WALL SECTION

SCALE = 1:203 WINDOW W2 TYP. WALL SECTIONSCALE = 1:204 WINDOW W1 TYP. WALL SECTION

SCALE = 1:20

11 TYPICAL JAMB DETAIL AT COLUMNSCALE = 1:5 6 TYPICAL W3 SILL DETAIL

SCALE = 1:5

5 TYPICAL W3 HEAD DETAILSCALE = 1:57 TYPICAL W2 HEAD DETAIL

SCALE = 1:5

8 TYPICAL W2 & W3 SILL DETAILSCALE = 1:20

9 TYPICAL W1 HEAD DETAILSCALE = 1:5

10 TYPICAL W3 SETION DETAILSCALE = 1:5

12 TYPICAL W3 SILL DETAILSCALE = 1:513 TYPICAL W3 SILL DETAIL

SCALE = 1:5

Page 7: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

2

A500

1

A500

TYPTYP4

A500

3

A500

TYP TYP

..\..\..\..\Production\17l21 Branding\1721 architects_ Logo Package\11_21 architects_ Logo Package\FOR DIGITAL (MS Office, Social Media, Web...)\17_21 architects_LOGO_RGB.jpg

ISSUED

KEY PLAN

LEGEND

A300

BRIDGEVIEW CLASSROOM RENOVATION AND WINDOW REPLANCEMENT

205 ALBERT ST, POINT EDWARD, ON N7V 1R4

BUILDING ELEVATIONSWINDOW TYPES

MFPU2011

AS NOTED

2021-02-26 ISSUED FOR OWNER REVIEW 1

2021-03-04 ISSUED FOR TENDER 2

2 PART NORTH BUILDING ELEVATIONSCALE = 1:100 1 PART NORTH BUILDING ELEVATION

SCALE = 1:100

3 PART SOUTH BUILDING ELEVATIONSCALE = 1:100

4 PART WEST BUILDING ELEVATIONSCALE = 1:100

5 WINDOW TYPESSCALE = 1:50

Page 8: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …
Page 9: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

MECHANICAL LEGEND

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

CONDENSATE DRAIN

HOT WATER HEATING RETURN

HOT WATER HEATING SUPPLY

REFRIGERANT LIQUID

REFRIGERANT SUCTION

SANITARY DRAIN

SHUT OFF VALVE

CHECK VALVE

COMBINATION SHUT-OFF, BALANCE & CHECK VALVE

PRESSURE REDUCING VALVE

TWO-WAY CONTROL VALVE

BALL VALVE

FLOW CONTROL VALVE

COMBINATION SHUT-OFF & BALANCING VALVE

SUPERVISED VALVE

PRESSURE GAUGE COCK

DRAIN WITH HOSE CONNECTION

FREEZE PROOF WALL HYDRANT

UNION

CLEANOUT IN WALL

CLEANOUT PLUG

CLEANOUT IN FLOOR

CONCENTRIC REDUCER

STRAINER

STRAINER C/W BLOW OFF

THREE-WAY CONTROL VALVE

TEMPERATURE-PRESSURE RELIEF VALVE (TPV) OR PRESSURE

EXISTING PIPING TO REMAIN

EXISTING PIPING TO BE REMOVED

RELIEF VALVE (RV)

CAP

THERMOMETER

PRESSURE GAUGE

EXISTING DUCTWORK TO REMAIN

EXISTING DUCTWORK TO BE REMOVED

NEW DUCTWORK

INTERNALLY INSULATED DUCTWORK

FORCE FLOW HEATER OR FAN COIL UNIT

SUPPLY DIFFUSER/GRILLE/REGISTER

RETURN GRILLE/REGISTER

EXHAUST GRILLE/REGISTER

WALL-FIN ENCLOSURE AND ELEMENT

BALANCING DAMPER

FIRE DAMPER

OPPOSED BLADE DAMPER - AUTOMATIC OPERATOR

BD

REHEAT COIL - HYDRONIC OR ELECTRIC

FD

PLUMBING FIXTURE TAG DESIGNATION

HEATING ELEMENT WITH THREE WAY CONTROL VALVE3

WALL-FIN/CONVECTOR DESIGNATOR

TYPE

ELEMENT LENGTH

(INCHES OR MM)

TYPE

AIR QUANTITY

(CFM OR L/S)

DIFFUSER/REGISTER/GRILLE DESIGNATOR

VALVE FLOW RATE

MECHANICAL EQUIPMENT TAG

FIRE EXTINGUISHER - SURFACE MOUNTED

FEX

THERMOSTAT

FLOOR DRAIN

ROOF DRAIN

-

- - -

- -

CD

HWR

HWS

RL

RS

SAN

V

S

CO

CO

CO

T

FD

RD

NAME(E)

NAME(E)

100

SD-1

A-1

24

EF-1

EF

201

0.00

L/S

A1

UNIT VENTILATORS

DRAWING

REFERENCE

SERVICE MANUFACTURER MODEL

AIR FLOW

(L/s)

E.S.P.

(Pa)

SUPPLY FAN

HP

MINIMUM

O.A.

(L/s)

DX COOLING HEATING ELECTRICAL ENERGY RECOVERY WHEEL - HEATING ENERGY RECOVERY WHEEL - COOLING

REMARKS

TOTAL

(kW)

FLOW

(L/s)

W.P.D.

(kPa)

EWT (°C) LWT (°C) EAT (°C) LAT (°C)

TOTAL

(kW)

V/Ph/Hz MCA

OA

(L/s)

OA

DB (°C)

ROOM AIR

DB (°C)

LAT

DB (°C)

CAPACITY

(kW)

OA

(L/s)

OA DB/WB

(°C)

ROOM AIR

DB/WB (°C)

LAT

DB/WB (°C)

CAPACITY

(kW)

UV-401 CLASSROOMS CHANGE'AIR HRA ERW 470 63 1/2 210 9.6 0.22 2.76 71.1 54.6 7.2 32.4 15 208/3/60 23.4 210 -19.4 22.2 7.75 8.5 210 30/22.2 23.9/17.2 25.8/19.3 2.4 TWO STAGES OF COOLING

GRILLES, REGISTERS AND DIFFUSERS

DRAWING

REFERENCE

MANUFACTURER MODEL

PANEL SIZE

(mm)

NECK SIZE

(mm)

AIR VOLUME

(L/s)

REMARKS

SD-1 PRICE SPD/31/B12 600x600 150Ø 0-70 STEEL CONSTRUCTION SQUARE PLAQUE DIFFUSER, EQUALIZING GRID, WHITE FINISH

SD-2 PRICE SPD/31/B12 600x600 200Ø 71-110 STEEL CONSTRUCTION SQUARE PLAQUE DIFFUSER, EQUALIZING GRID, WHITE FINISH

SD-3 PRICE SPD/31/B12 600x600 250Ø 111-150 STEEL CONSTRUCTION SQUARE PLAQUE DIFFUSER, EQUALIZING GRID, WHITE FINISH

RG-1 PRICE PDDR/3/B12 600x600 250x250 0-260 STEEL CONSTRUCTION PERFORATED FACE GRILLE, HINGED FACE, WHITE FINISH

RG-2 PRICE PDDR/3/B12 600x600 550x550 0-1000 STEEL CONSTRUCTION PERFORATED FACE GRILLE, HINGED FACE, WHITE FINISH

EG-1 PRICE 80/F/B12 250x250 250x250 0-140 EXTRUDED ALUMINUM CONSTRUCTION EGG CRATE GRILLE, ALUMINUM GRID CORE, FLAT BORDER, WHITE FINISH

MECHANICAL DRAWING LIST

M100MECHANICAL LEGEND, SCHEDULES & DRAWINGS LIST

M200 PART FLOOR PLAN - PLUMBING

M300 PART FLOOR PLAN - HEATING

M400 PART FLOOR PLAN - AIR DISTRIBUTION

HEATING UNITS

DRAWING

REFERENCE

SERVICE MANUFACTURER MODEL

SIZE HEIGHT X DEPTH

(mm)

CAPACITY

(W)

TEMPERATURE

REMARKS

EAT (°C) EWT (°C) LWT (°C)

A-1 PERIMETER HEAT SIGMA SWE-24S SEE DRAWINGS 1600 W/m 18 82 71 TWO ROW, PROVIDE ENCLOSURE LENGTH TO SUIT REVISIONS.

SPLIT SYSTEM AIR CONDITIONING UNITS

DRAWING

REFERENCE

LOCATION SERVICE MANUFACTURER MODEL

NORMAL

COOLING

CAPACITY

(kW)

ELECTRICAL

OA TO UNIT

(L/s)

REMARKS

EAT (°C) EWT (°C)

INDOOR UNIT

AC-521

CUSTODIAL

OFFICE

CUSTODIAL

OFFICE

DAIKIN FDXS09LVJU 2.5 208/1/60 8 15 CONCEALED UNIT IN CEILING SPACE, c/w 50MM FILTER BOX

OUTDOOR UNIT

CU-621 ROOF AC-521 DAIKIN RXS09LVJU 2.50 - 8 - OUTDOOR UNIT

SPLIT SYSTEM FAN COIL WITH FILTER BOX DETAILS

N.T.S.

NOTE: ARRANGEMENT TYPICAL FOR FAN COIL UNITS.

ELEVATION

FAN COIL UNIT

FAN

COIL

UNIT

SUPPLY AIR OUTLET

SUPPLY AIR OUTLET

RETURN AIR INLET

FILTER BOX BY FAN COIL

UNIT MANUFACTURER.

FILTER

CLEARANCE

FLEXIBLE DUCT

CONNECTION

FILTER

PLAN

RETURN AIR INLET

FLEXIBLE DUCT

CONNECTION

FILTER BOX BY FAN COIL

UNIT MANUFACTURER.

FILTER

FLEXIBLE DUCT

CONNECTION

FLEXIBLE DUCT

CONNECTION

STAND MOUNTED CONDENSING UNIT

ROOF

N.T.S.

INSTALLATION DETAIL

PRECAST CONCRETE

PAVING STONE

25mm RIGID

INSULATION

CONDENSING UNIT SUPPORT

FRAME. FASTENED TO PAVING

STONE. SEE SPECIFICATION FOR

DETAILS.

CONDENSING UNIT

H

W

S

H

W

R

H

E

A

T

I

N

G

C

O

I

L

N.T.S.

TYPICAL PIPING ARRANGEMENT FOR

HEATING COILS WITH 2-WAY CONTROL VALVE

45° MAX.30° MAX.

PLAN

ELEVATION

AIR FLOW AIR FLOW

HEATING COIL INSTALLATION

N.T.S.

ACCESS DOOR

BOTTOM OF DUCT

ACCESS DOOR

BOTTOM OF DUCT

HEATING COIL

HEATING COILS

MAY BE DIRECTLY

CONNECTED TO

DUCT

HEATING COIL

ACCESS DOOR

BOTTOM OF DUCT

AIR FLOWAIR FLOW

FIL

E N

AM

E:

91

38

DM

01

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 1

1:2

4 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 1

1:2

6 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

MECHANICAL LEGEND,DRAWING LIST & SCHEDULES

JDFKDM

1:100M100

Page 10: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

18

6

G27

8

9

10

B2

S111

18A

18

6G2

7 8

910

B2

S111

M1

CUST

SS1

SS1 EX

REM REM

EXREM

CO(E)

CO(E)

CO

SS1

SS2

A

M200 M200

FPWH(E)

FPWH(E)

REM

PART FLOOR PLAN

PLUMBING

SCALE: 1:100

PART FLOOR PLAN

PLUMBING DEMOLITION

15

15

1515

– (E)

– (E

)

– (E

)

– (E

)

– (E

)

15

15

1515

– (E)– (E)

– (E

)

– (E

)

– (E

)

– (E

)

– (E)

– (E

)

SAN(E)SAN(E)

SA

N(E

)

75 75

SAN(E)

40

75

75

SA

N(E

)

SAN(E)SAN(E)

150

100

SA

N(E

)

150

SAN(E)SAN(E)

SA

N(E

)

75 75

SAN(E)

40

75

75

SA

N(E

)

SAN(E)SAN(E)

150

100

SA

N(E

)

150

150

CTE

CTE

CTE

CTE

SAN

CTE

CTE

CTE

CTE

CTE

CTE

75

– –

(E

)

– –

(E

)

15

15

2020

– (E)

– (E

)

– –

(E

)

– –

(E

)

15

15

2020

15

– – (E)

– – – (E)

– (E)

15

– (E

)

15

– (E

)

CTECTECTE

CTE

150

20

CTE

FD(E)

FD(E)

SA

N

75

FD(E)

FD(E)

REM

WC

REM

LAV

– – (E)

– – – (E)

– – (E)

– – – (E)

– – (E)

– – – (E)

– – (E)

– – – (E)

– – (E)

– – – (E)

SCALE: 1:100

NOTES:

1. MINIMUM BELOW GRADE PIPE SIZE IS 75MM.

75

FFD

18A

WC1

LA1

SS1

CTE

DETAIL

SCALE: 1:50

A

M200M200

15

15

15

15

20

20

– (E

)

– – (E

)

15

FIL

E N

AM

E:

91

38

DM

02

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 9

:5

9 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 1

1:2

6 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

PART FLOOR PLANSPLUMBINGDEMOLITION & NEW

JDFKDM

1:100M200

Page 11: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

REM

4.4

EX

4.4

EX

4.4

REM

4.4

EX

4.4

EX

4.4

EX

5.9

EX

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

REM

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

REM

WFC

REM

WFC

EX

FF

EX

UH

EX

FF

EX

FF

T

T

T

T

TT

T

T

T

T

T

T

T

T

EX

5.9

EX

2.2

T

T

EX

2.2

UV

401

EX

4.4

EX

4.4

A-1

4.4

EX

4.4

EX

4.4

EX

5.9

EX

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

A-1

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

EX

4.4

EX

FF

EX

UH

EX

FF

EX

FF

T

T

T

T

TT

T

T

T

T

T

T

EX

5.9

EX

2.2

T

T

EX

2.2

18 6 G2

7

8

9

10

B2

S1

11

18A

18

6

G2

7 8

910

B2

S111

M1

CUST

HC

1

T

A-1

800

AC

521

CU

621

UV

401

A-1

4.4

UV

401

UV

401

MV

PART FLOOR PLAN

HEATING

SCALE: 1:100

PART FLOOR PLAN

HEATING DEMOLITION

32

32

5050

20

5065

32

25 HWS/HWR DN

40

32

20

20 HWS/HWR DN

32

50

25

32

32

HW

R(E

)

HW

S(E

)

HW

R(E

)

HW

S(E

)

HWS(E)

HWR(E) HWR(E)

HWS(E)

HWS(E)

HWR(E)

HW

S(E

)

HW

R(E

)

HW

R(E

)

HW

S(E

)

32

HW

S(E

)

HW

R(E

)

32

HW

R(E

)

HW

S(E

)

32

32

5050

20

5065

32

25 HWS/HWR DN

40

32

20

32

50

25

32

32

HW

R(E

)

HW

S(E

)

HW

R(E

)

HW

S(E

)

HWS(E)

HWR(E) HWR(E)

HWS(E)

HW

S(E

)

HW

R(E

)

HWS(E)

HWR(E)

HW

S(E

)

HW

R(E

)

HW

R(E

)

HW

S(E

)

32

HW

S(E

)

HW

R(E

)

32

HW

R(E

)

HW

S(E

)

RL

RS

HW

S

HW

R

20

CTE

(ON ROOF)

HW

S(E

)

HW

R(E

)

CTE

CTE

CTE

CTE

CTE

RS

RL

N.T.S.

DETAIL OF CONDENSATE

PIPE TERMINATION AT WALL

C.O.

25

STAINLESS STEEL

EXTERIOR WALL

CD FROM UNIT

GRADE

75

300

ENCLOSURE BY

MECHANICAL

CONTRACTOR.

N.T.S.

TYPICAL PIPING ARRANGEMENT FOR

CONVECTORS W/ 2 ROWS - 2 WAY VALVE

H

W

R

H

W

S

M

V

C

O

N

V

E

C

T

O

R

S

E

N

C

L

O

S

U

R

E

HW

R

HW

S

UNIT VENTILATOR PIPING ARRANGEMENT

WITH TWO-WAY CONTROL VALVE

N.T.S.

DIV

. 1

5U

.V

. S

UP

PL

IE

R

UNIT

VENTILATOR

20

CD

20 CD DN TO FFD. SEE DETAIL

ON THIS DRAWING.

SCALE: 1:100

NOTE:

1. MINIMUM PIPE SIZE IS 20MM.

32

32

32

HWS

HWR

20

MOUNT FUNNEL FLOOR

DRAIN WITH STRAINER

FLUSH WITH BOTTOM OF

MILLWORK CABINET.

FLOOR

MILLWORK

CD

RUN CONDENSATE IN

WALL AND ENTER

MILLWORK AT LOW

LEVEL.

N.T.S.

MILLWORK MOUNTING DETAIL

FUNNEL FLOOR DRAIN

PROVIDE FUNNEL COVER

NOTCHED TO SUIT

CONDENSATE PIPING.

FIL

E N

AM

E:

91

38

DM

03

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 1

0:5

4 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 1

1:2

7 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

PART FLOOR PLANHEATING

JDFKDM

1:100M300

Page 12: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

SCALE: 1:100

PART FLOOR PLAN

AIR DISTRIBUTION

37

5x1

50

37

5x2

50

37

5x1

50

37

5x1

75

375x150

550x550 E.A.(E)

UP TO EF

475x300

375x300

EG-1

25

350x175

32

5x1

75

350x175

27

5x1

75

22

5x1

25

20

0x1

25

EX

EG

SCALE: 1:100

PART FLOOR PLAN

AIR DISTRIBUTION DEMOLITION

450x300

32

5x1

50

37

5x1

50

37

5x2

50

37

5x1

50

37

5x1

75

375x150

350x300

32

5x1

50

325x150

550x550 E.A.(E)

UP TO EF

475x300

375x300

EX

EG

REM

EG

REM

150

EX

EG

REM

EG

REM

EG

REM

EG

350x175

32

5x1

75

350x175

27

5x1

75

22

5x1

25

20

0x1

25

EX

EG

EX

EG

EX

EG

EX

EG

EX

EG

150MM WIDE SHROUD

PROVIDED BY UNIT

VENTILATOR

MANUFACTURER.

18

6

G2

7

8

910

B2

S1

11

18A

18

6CLASSROOM

G2

7CLASSROOM

8CLASSROOM

9STAFF ROOM

10CLASSROOM

B2

S111

M1

CUST

150ø

150ø

150ø

150ø

150ø

200ø

200ø

200ø

200ø

200ø

55

0x2

50

55

0x2

50

1025x950 LOUVRE.

REFER TO STRUCTURAL

DRAWINGS FOR NEW

OPENINGS.

150MM WIDE SHROUD

PROVIDED BY UNIT

VENTILATOR MANUFACTURER.

SD-1

50

15

SD-1

65

TYPICAL

OF 6

15

20

0x1

00

REM

EG

15

0x7

5

225x100

20

0x1

00

15

0x7

5

225x100

CAP

350x150

15

BD

30

0x1

50

AC

521

SD-3

135

RG-1

120

300x200 BRICK VENT

HC

1

CTE

200ø

200ø

200ø

200ø

300x200

BRICK VENT

RANGE HOOD

UV

401

UV

401

UV

401

200ø

200ø

200ø

200ø

200ø

55

0x2

50

SD-2

80

TYPICAL

OF 6

150MM WIDE SHROUD

PROVIDED BY UNIT

VENTILATOR

MANUFACTURER.

1025x950 LOUVRE.

REFER TO STRUCTURAL

DRAWINGS FOR NEW

OPENINGS.

150MM WIDE SHROUD

PROVIDED BY UNIT

VENTILATOR MANUFACTURER.

UV

401

CAP

350x300325x150

EX

EG

CAP

CAP

CAP

450x300

400x400 E.A.(E)

UP TO EF

200ø

150ø

1025x950 LOUVRE.

REFER TO STRUCTURAL

DRAWINGS FOR NEW

OPENINGS.

EX

EG

EX

EG

EX

EG

EX

EG

EX

EG

200ø

1

M400 M400

55

0x2

50

SD-2

80

TYPICAL

OF 6

SD-2

80

TYPICAL

OF 6

200ø

150x75

BD

N.T.S.

TYPICAL FLEXIBLE RUNOUT TO SUPPLY DIFFUSER

MIN 300

SUPPORT IN AT LEAST

TWO LOCATIONS

FLEXIBLE DUCTWORK

(MIN. LENGTH = 1830MM)

SCREW, TAPE AND SEAL ALL

CONNECTIONS AS SPECIFIED

SUPPLY DIFFUSER

FLEX-FLO ELBOW

SUPPORT ACCESSORY

D

C

A

B

N.T.S.

CEILING RETURN GRILLE & BOOT DETAIL

E

NOTE:

1. INTERNALLY LINE DUCTWORK.

RG-2

DIMENSIONS

A B C D E

550 550 300 200 300

RG-2

-

RG-2

-

RG-2

-

RG-2

-

RG-2

-

RG-2

-

RG-2

-

RG-2

-

TYPICAL

100ø

EXTENSION PROVIDED BY

UNIT MANUFACTURER. FINISH

TO MATCH UNIT VENTILATOR.

EXTEND TO NEW ACT

CEILING.

SUPPLY AIR FAN ON

VIBRATION ISOLATORS

HOT WATER HEATING

COIL

CONDENSER COIL &

COMPRESSOR

PUNCHED RETURN AIR

GRILLE

DX COOLING COIL

RETURN AIR DAMPER

FLEXIBLE CONNECTION

950x1025H LOUVRE SUPPLIED

BY MECHANICAL CONTRACTOR.

PROVIDE CONTINUOUS FOAM

GASKET WHERE UNIT MEETS

THE WALL. ANY GAP AT THE

WALL WILL BE UNACCEPTABLE.

ENERGY RECOVERY WHEEL

SECTION

SCALE: 1:25

1

M400M400

SEE PLANS FOR

SIZE

EXTERNALLY INSULATED SLEEVE C/W

DIVIDER PANEL TO BE PROVIDED BY

MECHANICAL CONTRACTOR, PROVIDE 1

PIECE TRIM TO CONCEAL SLEEVE, PANEL

ETC. CONFIRM EXACT DIMENSIONS ON

SITE. FASTENERS TO BE CONCEALED.

FIL

E N

AM

E:

91

38

DM

04

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 1

0:0

7 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 1

1:3

0 A

M

201 QUEENS AVE., UNIT 800LONDONON N6A 1J1,

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

PART FLOOR PLANAIR DISTRIBUTION

JDFKDM

1:100

Page 13: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

MECHANICAL EQUIPMENT SCHEDULE

EQUIPMENT SUPPLIED AND INSTALLED

BY DIVISION 15, WIRED BY DIVISION 16

CONTROL EQUIPMENT

SUPPLIED AND

INSTALLED BY

DIVISION 16

BR

EA

KE

R/F

US

E S

IZ

E

PO

LE

S

CO

ND

UC

TO

R S

IZ

E

CO

ND

UIT

S

IZ

E

ITEM DESCRIPTION LOCATION

hp

MCA PHASE VOLTS

STARTER/CONTROL

TYPE

FED FROM NOTES

AC 521

AIR CONDITIONING UNIT INDOOR

UNIT

CUSTODIAL 2#12 1/2"PROVIDE 3#12, 1/2"C FROM CU TO AC UNIT

CU 621

AIR CONDITIONING UNIT OUTDOOR

UNIT

ROOF 8 1 208 PANEL B 15 2 2#12 1/2"

UV 401 UNIT VENTILATORS CLASSROOMS 23.4 3 208 PANEL RM 9 30 3 3#10 3/4"

NOTES:

1. DIVISION 16 TO OBTAIN COPIES OF MECHANICAL EQUIPMENT SHOP DRAWINGS AND COORDINATE ELECTRICAL SERVICES.

2. PROVIDE LOCAL NON-FUSED DISCONNECT SWITCHES AT MOTORS IN ACCORDANCE WITH SECTION 28-604 OF THE ONTARIO ELECTRICAL SAFETY CODE.

3. UNLESS INDICATED OTHERWISE ALL CONTROL WIRING IS BY DIVISION 15.

4. CONTROLLER PROVIDED BY MECHANICAL DIVISIONS, INSTALLED AND WIRED BY DIVISION 16.

5. PROVIDE 2#12, 1/2"C FROM OUTDOOR UNIT TO INDOOR UNIT FOR AC-521.

ABBREVIATIONS

P POLE

HOUSE KEEPING

EXISTING TO REMAIN

DIGITAL METERING SYSTEM

DIRECT CURRENT

FLUSH CEILING MOUNTED

NEW DEVICE

ISOLATED GROUND

MOISTURE PROOF

ABOVE COUNTER - 230mm (9")

GROUND FAULT DEVICEGFCI

MP

NEW

OC

H

IG

DC

DMS

EX

C

CL

CONDUIT

EXPLOSION PROOF

TAMPER PROOF

EXISTING TO BE REMOVED

PATIENT SERVICE COLUMN

WEATHERPROOF

UNINTERRUPTIBLE POWER SUPPLY

EXISTING TO BE REPLACED WITH NEW

TP

XP

WP

WG

UPS

WIRE GUARD

REL

REM

REP

PH

PSC

PHASE

T/S TIME SWITCH

WIREMOLDWM

IF DASHED - EXISTING TO BE RELOCATED

REL IF SOLID - EXISTING IN NEW LOCATION

CHILDPROOF/TAMPER PROOF OUTLETCP

REMOVE AND REINSTALLRR

ALST ALTERNATOR STARTER

COMB COMBINATION DISCONNECT SWITCH & STARTER ON WALL ADJACENT MOTOR

CON CONTACTOR

DC DIRECT CONNECTION

DS UN-FUSED DISCONNECT SWITCH

DPS DOUBLE-POLE SWITCH

FDS FUSED DISCONNECT SWITCH

FHP FRACTIONAL HORSE POWER

FVNR FULL VOLTAGE NON-REVERSING STARTER C/W H.O.A. SWITCH

FLA FULL LOAD AMPS

HOA HAND-OFF-AUTO SELECTOR SWITCH

MAN MANUAL STARTER

MCA MINIMUM CIRCUIT AMPACITY

MCC MOTOR CONTROL CENTRE

PL PILOT LIGHT

2S HIGH-OFF-LOW-SPEED SELECTOR SWITCH C/W 15 SECOND TIME DELAY FROM HIGH SPEED TO LOWER SPEED AND

H.O.A. SWITCH

REC DUPLEX RECEPTACLE

SPS SINGLE POLE SWITCH

SS START-STOP

VFD VARIABLE SPEED DRIVE

MOTOR CONTROL ABBREVIATIONS

1. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS, VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH THE

EXISTING BUILDING, EQUIPMENT AND SYSTEMS TO DETERMINE THE FULL EXTENT OF DEMOLITION AND RENOVATION

WORK.

2. RENOVATIONS SHALL BE MADE ON THE EXISTING BUILDING AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN.

REMOVE ALL REDUNDANT ELECTRICAL EQUIPMENT AND CONDUITS. ONLY CONDUITS AND DEVICE BOXES THAT ARE IN

VERY GOOD CONDITION MAY REMAIN AND BE REUSED. ALL EQUIPMENT REMOVED AND NOT REUSED SHALL BE HANDED

OVER TO THE OWNER AND/OR BE DISCARDED AT THE OWNER'S DISCRETION.

3. REMOVE, PROTECT AND REINSTALL IN THE SAME OR NEW LOCATION ON NEW SURFACES ALL EXISTING ELECTRICAL

EQUIPMENT THAT WILL BE REUSED. EQUIPMENT IDENTIFIED FOR REUSE THAT IS LOST OR DAMAGED MUST BE REPLACED

AT NO COST TO THE OWNER.

4. CONCEAL ALL CONDUITS AND BOXES IN EXISTING WALLS WHERE POSSIBLE. PROVIDE WIREMOLD 700 SERIES SURFACE

RACEWAY FOR NEW DEVICES ON EXISTING WALLS THAT CANNOT HAVE CONCEALED SERVICES. PROVIDE APPROPRIATE

SURFACE RACEWAY DEVICE BOXES.

ELECTRICAL GENERAL NOTES

ELECTRICAL DRAWING LIST

E-100 ELECTRICAL LEGEND, KEYPLAN, ABBREVIATIONS, DRAWING LIST,

SCHEDULES, DETAILS, AND NOTES

E-200 PART FLOOR PLAN LIGHTING AND FIRE ALARM, POWER AND SYSTEMS

E-300 PART FLOOR PLAN DEMOLITION

E-400 ELECTRICAL DETAILS

LUMINAIRE SCHEDULE

TYPE MANUFACTURER

MOUNTING

LAMPS

SYSTEM

WATTAGE

VOLTS EQUAL MANUFACTURERS REMARKS

TYPE HEIGHT

A LITHONIA LIGHTING CAT # 2TL4-48L-FW-A19-MVOLT-LP840 RECESSED CEILING 4700 LU LED 42 120

CFI, LITHONIA, METALUX, THOMAS, WILLIAMS,

VISIONEERING

NOTES:

1. REFER TO ARCHITECTURAL REFLECTED CEILING DRAWINGS TO CONFIRM LUMINAIRE MOUNTING PRIOR TO ORDERING. SUPPLY APPROPRIATE MOUNTING CLIPS AND/OR TRIMS AS REQUIRED.

2. PROVIDE ALL ACCESSORIES AS REQUIRED. PROVIDE LOW PROFILE SURFACE RACEWAY TO CONCEAL ALL EXPOSED WIRING.

3. CONFIRM RUN LENGTHS WITH MILLWORK SHOP DRAWINGS PRIOR TO ORDERING.

4. EQUAL MANUFACTURERS TO SUBMIT WORKING SAMPLES TO CONSULTANT MINIMUM OF 5 WORKING DAYS PRIOR TO TENDER CLOSING.

5. ALL INTERIOR LUMINARIES CONNECTED TO DIMMABLE ROOM CONTROLLERS TO BE 0-10V DIMMABLE.

6. PROVIDE ALL ACCESSORIES AND TRANSFORMER AS REQUIRED FOR A COMPLETE SYSTEM. LUMINAIRE SCHEDULE IS DENOTED AS 4'-0" LENGTH REFER TO FLOOR PLANS FOR ACTUAL RUN LENGTHS.

ELECTRICAL LEGEND

SYMBOL DESCRIPTION MOUNTING

VFD VARIABLE FREQUENCY DRIVE

MOTOR

MOTOR c/w DISCONNECT SWITCH

MOTOR c/w FUSED DISCONNECT SWITCH

NONFUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

MANUAL STARTER

MAGNETIC STARTER

COMBINATION MAGNETIC STARTER

CONTACTOR

AS NOTED

C

ELECTRICAL PANEL

JUNCTION BOXJB

EMERGENCY CALL STATION AND INDICATOR - ROUGH-IN ONLY,

COORDINATE WITH HARDWARE SUPPLIER

CORRIDOR DOME LIGHT AND AUDIBLE ALARM - ROUGH-IN

ONLY, COORDINATE WITH HARDWARE SUPPLIER

AUTOMATIC DOOR LOCK SENSOR - ROUGH-IN ONLY

COORDINATE WITH HARDWARE SUPPLIER

OCCUPIED WHEN LIT - ROUGH-IN ONLY

COORDINATE WITH HARDWARE SUPPLIER

DOOR JAM DOOR STRIKE - ROUGH-IN ONLY

COORDINATE WITH HARDWARE SUPPLIER

POWER DOOR OPERATOR AND INDICATOR - ROUGH-IN

ONLY, COORDINATE WITH HARDWARE SUPPLIER

PUSH TO LOCK BUTTON - ROUGH-IN ONLY

COORDINATE WITH HARDWARE SUPPLIER

REFER TO ARCHITECTURAL

DRAWINGS

REFER TO ARCHITECTURAL

DRAWINGS

PTLB

PDO

DJS

CDL

ECS

ADLS

OWL

REFER TO ARCHITECTURAL

DRAWINGS

REFER TO ARCHITECTURAL

DRAWINGS

REFER TO ARCHITECTURAL

DRAWINGS

REFER TO ARCHITECTURAL

DRAWINGS

REFER TO ARCHITECTURAL

DRAWINGS

D HAND DRYER

T TRANSFORMER AS NOTED

PAGING SPEAKER

CEILING MOUNTED (SURFACE)

PS

LUMINAIRE - NORMAL POWER RECESSEDA

EMERGENCY BATTERY PACK c/w DUAL HEADS WALL MOUNTED

OCCUPANCY SENSOR SWITCH

1100mm (43") A.F.F.

15/20 AMP 120 VOLT 3 WIRE GROUNDED DUPLEX RECEPTACLE CSA

5-20R

460mm (18") A.F.F.

15/20 AMP 120 VOLT 3 WIRE GROUNDED DUPLEX RECEPTACLE CSA

5-20R

ABOVE COUNTER

DIRECT POWER CONNECTION

50 AMP 250 VOLT 4 WIRE GROUNDED RANGE RECEPTACLE

200mm (8") A.F.F.

AS NOTED

R

FIRE ALARM VISUAL SIGNAL (15 CD)

WALL 2300mm (91") A.F.F.

MAX 2400 (95") A.F.F.

PADDLE FAN

INTERCOM

IC

A.F.F. AWAY FROM FLOOR

A.F.C. AWAY FROM CEILING

SCALE: 1:200

MAIN FLOOR PLAN

AREA OF WORK

FIL

E N

AM

E:

91

38

DE

01

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 9

:3

1 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 9

:3

5 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

ELECTRICAL LEGEND, KEYPLANABBREVIATIONS, DRAWING LIST,SCHEDULES, AND NOTES

RDGTJR

1:100 E100

Page 14: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

PART FLOOR PLAN

LIGHTING AND FIRE ALARM

18 G2

B2

S111

18A

M1

PART FLOOR PLAN

POWER AND SYSTEMS

18G2

B2

S111

18A

M1

GFCI

WP

UV

401

UV

401

UV

401

AC

521

CU

621

ON ROOF

AA

A A

A A

NOTE 1

NOTE 2

SCALE: 1:100

NOTES:

1. CONNECT TO NEAREST FIRE ALARM

VISUAL SIGNALING CIRCUIT SERVING THE

AREA. REPLACE EXISTING END OF LINE

RESISTOR AS REQUIRED. IF NECESSARY,

RUN BACK TO MAIN FIRE ALARM IN MAIN

ELECTRICAL ROOM.

2. CONNECT NEW SWITCHES EMERGENCY

BATTERY PACK AND LUMINARIES TO

EXISTING CIRCUIT SERVING THE AREA.

3. CONNECT NEW LIGHTING TO EXISTING

CIRCUITS AND SWITCHING.

4. PROVIDE WIREMOLD DOWN TO SWITCH.

5. RELOCATE EXISTING INTERCOM. PROVIDE

SURFACE BOX.

ON ROOF

SEE DETAIL

MICROWAVE

FRIDGE

GFCI GFCI

60" A.F.F.

R

STOVE

HOOD FAN

(120V)

GFCI

GFCI

FRIDGE

EXISTING PANEL

ROOM 9

EXISTING PANEL B

EXISTING PANEL

ROOM 9

EXISTING PANEL B

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

PSECS

PDOPTLB

OWLCDLPDO

DJS

ADLS

D

T

A

A

A

A

A

A

A

A

A

A

A

A

NOTE 3 NOTE 3

NOTE 3NOTE 3

NOTE 2

SCALE: 1:100

NOTES:

1. RELOCATED WIFI ANTENNA DOWN TO NEW

CEILING.

2. PROVIDE NEW BREAKERS FOR EXISTING

SIEMENS PANELS. SEE PANEL SCHEDULE.

3. REFER TO WASHROOM EMERGENCY CALL

SCHEMATIC FOR ALL REQUIREMENTS IN

UNIVERSAL WASHROOMS.

6STAFF ROOM

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

6STAFF ROOM

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOM

RM9 - 7,9,11RM9 - 13,15,17

RM9 - 19, 21,23

NOTE 2

RM9 - 20

RM9 - 18

RM9 - 29

RM9 - 27

B - 18, 20

B - 27, 29

B - 22

B - 24

B - 26

B - 28

B - 30

B - 25

B - 25

NOTE 1 NOTE 1

NOTE 1NOTE 1

UV

401

B - 19, 21,23

NOTE 4

NOTE 5

IC

IC

EX

8" A.F.C.

NOTE 3

FIL

E N

AM

E:

91

38

DE

02

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 9

:3

1 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 9

:3

5 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

PART FLOOR PLANLIGHTING AND FIRE ALARM,POWER AND SYSTEMS

RDGTJR

1:100 E200

Page 15: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

PART FLOOR PLAN

DEMOLITION

18

6STAFF ROOM

G2

7CLASSROOM

8CLASSROOM

9CLASSROOM

10CLASSROOMB2

S111

CUST

EXISTING PANEL

ROOM 9

EXISTING PANEL BEXISTING PANEL B

NOTE 2

SCALE: 1:100

NOTES:

1. DISCONNECT & REMOVE LIGHTING &

PADDLE FANS IN THIS ROOM.

2. DISCONNECT & REMOVE ELECTRICAL IN

THIS AREA.

REM

REM

REM REM

NOTE 1

REM

REM

REM REM

NOTE 1

REM

REM

REM REM

NOTE 1

REM

REM

REM REM

NOTE 1

REL

IC

FIL

E N

AM

E:

91

38

DE

03

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 9

:3

1 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 9

:3

5 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

PART FLOOR PLANDEMOLITION

RDGTJR

1:100E300

Page 16: BRIDGEVIEW ELEMENTARY SCHOOL CLASSROOM …

RECEPTACLE ROOF MOUNTING DETAIL

NOTES:

1. MAINTAIN A MINIMUM CLEARANCE OF 308mm (12") ON ALL SIDES

OF ROOF PENETRATION FROM WALLS, CURBS, AND OTHER

PROJECTIONS TO FACILITATE PROPER FLASHING.

2. FLANGES OF ADJACENT FLASHINGS SHALL NOT BE CUT OR

OVERLAPPED.

3. COORDINATE FLASHINGS INSTALLATION WITH GENERAL

CONTRACTOR TO ENSURE PROPER METHODS AND MATERIALS

ARE USED TO MAINTAIN ROOF WARRANTY.

4. COORDINATE PRECAST CONCRETE BASE REQUIREMENTS WITH

OTHER TRADES.

5. ALL UNISTRUT AND ASSOCIATED MOUNTING HARDWARE TO BE

ALUMINIUM.

6. COORDINATE WITH DIVISION 15 FOR SHARED USE OF FLASHING

WHERE SPECIFIED AND PRACTICABLE.

A

A

LOCKABLE, WEATHERPROOF

DISCONNECT SWITCH

LOCKABLE CAST METAL "IN-USE"

WEATHERPROOF COVER & GFCI

RECEPTACLE - DEDICATED

CIRCUIT

DRILL HOLES IN BOTTOM OF

ENCLOSURE FOR DRAINAGE

SEAL TIGHT RACEWAY

PVC JUNCTION BOX

SEAL TIGHT RACEWAY

PORTALS PLUS FLASHING

REFER TO SPECIFICATION

BATT INSULATION

DUCT SEAL

JUNCTION BOX

RECEPTACLE AND

MECHANICAL UNIT POWER

PRECAST

CONCRETE

PAD

ANCHOR UNISTRUT

TO CONCRETE PAD

UNISTRUT

CAST METAL NEMA

3R JUNCTION BOX

WITH THREADED HUB

MECHANICAL UNIT

ELEVATION SECTION "A-A"

750m

m

30" M

IN

N.T.S.

ELECTRONIC FAUCET CONTROL

N.T.S.

NOTES:

1. MOUNT TRANSFORMER AND JUNCTION BOX IN ACCESSIBLE CEILING

SPACE ABOVE SINKS.

2. DIVISION 16 TO PROVIDE ALL WIRING AND TERMINATIONS.

3. COORDINATE WITH DIVISION 15 EXACT LOCATION OF SINK TO

MINIMIZE EXPOSED WIRING. WIRING TO BE STUBBED OUT OF WALL

AT MAXIMUM 25mm BELOW BACK LEDGE OF SINK. PROVIDE 16mm

FLEX CONDUIT TO FAUCET.

2#18 IN 16mmC

(TYPICAL)

NOTE 3

2#12 IN 21mmC

TRANSFORMER

SUPPLIED BY

DIVISION 15

ELECTRONIC FAUCETS

BY DIVISION 15, REFER

TO FLOOR PLAN FOR

LOCATION AND

QUANTITY

WASHROOM EMERGENCY CALL SCHEMATIC

PS

120VAC BY

ELECTRICAL

CONTRACTOR

120VAC BY

ELECTRICAL

CONTRACTOR

WIRING BY

OTHERS

DEVICE LEGEND

WIRING BY

ELECTRICAL

CONTRACTOR

1

2

3

4

5

6

7

8

9

10

11

1 2 2 34 5 6

87

9

11

10

PUSH TO LOCK BUTTON BY DOOR HARDWARE

CONTRACTOR, DENOTED 'PTLB' ON FLOOR PLANS, NOTE 1

POWER DOOR OPERATOR SWITCH INSIDE/OUTSIDE

WASHROOM BY DOOR HARDWARE CONTRACTOR, DENOTED

'PDO' ON FLOOR PLANS, NOTE 1

OCCUPIED WHEN LIT BY DOOR HARDWARE CONTRACTOR,

DENOTED 'OWL' ON FLOOR PLANS NOTE 1

AUTOMATIC DOOR LOCK SENSOR BY DOOR HARDWARE

CONTRACTOR, DENOTED 'ADLS' ON FLOOR PLANS, NOTE 1

EMERGENCY CALL SWITCH AND INDICATOR LIGHT BY DOOR

HARDWARE CONTRACTOR, DENOTED 'ECS' ON FLOOR

PLANS, NOTE 1

DOOR JAMB DOOR STRIKE BY DOOR HARDWARE

CONTRACTOR, DENOTED 'DJS' ON FLOOR PLANS, NOTE 1

CORRIDOR DOME LIGHT AND BUZZER BY DOOR HARDWARE

CONTRACTOR, DENOTED 'CDL' ON FLOOR PLANS, NOTE 1

POWERED DOOR OPERATOR BY DOOR HARDWARE

CONTRACTOR, NOTE 1

UNIVERSAL/BARRIER FREE WASHROOM INTEGRATION

MODULE BY DOOR HARDWARE CONTRACTOR, NOTE 1

PAGING SPEAKER WITH TWO WAY COMMUNICATION

PROVIDED BY INTERCOM CONTRACTOR, NOTE 2

MOMENTARY CONTACT CLOSURE MODULE PROVIDED BY

INTERCOM CONTRACTOR FOR PA INTEGRATION, NOTE 2

N.T.S.

NOTES:

1. ELECTRICAL CONTRACTOR TO PROVIDE BACK BOX AND 21mm

(3/4") CONDUIT TO ACCESSIBLE CEILING SPACE. CONFIRM BACK

BOX REQUIREMENTS WITH HARDWARE SUPPLIER PRIOR TO

ROUGH-IN.

2. PAGING SPEAKER TO HAVE TWO WAY COMMUNICATION WITH

THE MAIN OFFICE. EMERGENCY CALL SWITCH TO ACT AS CALL

SWITCH TO INITIATE COMMUNICATION.

FIL

E N

AM

E:

91

38

DE

04

1.D

WG

DA

TE

S

AV

ED

:0

5-M

ar-2

02

1 9

:3

1 A

M

DA

TE

P

LO

TT

ED

:0

5-M

ar-2

02

1 9

:3

5 A

M

Chorley+

Bisset

CONSULTINGENGINEERS

chorleycom

250 CITYCENTREAVE

.

, SUITE

OTTAWAON, K1R6K7403201 QUEENS AVE., UNIT 800

LONDONON N6A 1J1,.

AREA OF WORK

ISSUED

ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION ARE COPYRIGHT

PROPERTY OF 17l21 ARCHITECTS INC. AND MUST BE RETURNED UPON REQUEST.

REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTATION IN

PART OR IN WHOLE IS WRITTEN FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF

17l21 ARCHITECTS INC.

DO NOT SCALE DRAWINGS

CONTRACTOR MUST CHECK AND VERIFY ALL DIMENSION OF THE JOB.

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE

ARCHITECT

BRIDGEVIEW CLASSROOMRENOVATION AND WINDOW REPLANCEMENT

205 Albert St, Point Edward, ON N7V 1R4

AREA OF WORK

9138

ELECTRICAL DETAILS

RDGTJR

1:100 E400