148
1 WAGO Rail-Mounted Terminal Block Systems Full Line Catalog, Volume 1 – Edition 2019/2020 WAGO PCB Terminal Blocks and WAGO Connectors Full Line Catalog, Volume 2 – Edition 2019/2020 2 3 Automation Technology Full Line Catalog, Volume 3 – Edition 2019/2020 4 WAGO Electronic Interface Full Line Catalog, Volume 4 – Edition 2019/2020 5 WAGO Pluggable Connection System WINSTA® Full Line Catalog, Volume 5 – Edition 2019/2020 6 WAGO Marking Full Line Catalog, Volume 6 – Edition 2019/2020 Automation Technology and WAGO Electronic Interface Supplementary Catalog to Full Line Catalogs, Volumes 3/4/6 Edition 2020/1

Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

1WAGO Rail-Mounted Terminal Block SystemsFull Line Catalog, Volume 1 – Edition 2019/2020

WAGO PCB Terminal Blocks and WAGO ConnectorsFull Line Catalog, Volume 2 – Edition 2019/2020 2 3Automation Technology

Full Line Catalog, Volume 3 – Edition 2019/2020

Auto

mat

ion

Tech

nolo

gy

Full L

ine

Cata

log

2019

/202

0

4 4WAGO Electronic InterfaceFull Line Catalog, Volume 4 – Edition 2019/2020 5WAGO Pluggable Connection System WINSTA®

Full Line Catalog, Volume 5 – Edition 2019/2020

WAG

O Pl

ugga

ble

Conn

ectio

n Sy

stem

WIN

STA®

Fu

ll Lin

e Ca

talo

g 20

19/2

020

6WAGO MarkingFull Line Catalog, Volume 6 – Edition 2019/2020

Automation Technology and WAGO Electronic InterfaceSupplementary Catalog to Full Line Catalogs, Volumes 3/4/6 Edition 2020/1

0888

-100

2/01

20-6

901

- Sup

pl. C

at. A

utom

atio

n Te

chno

logy

and

Elec

troni

c In

terfa

ce 2

020/

1 US

- 03

/202

0-00

- Pr

inte

d in

Ger

man

y - S

ubje

ct to

cha

nges

Page 2: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

3

Automation Technology

Full Line Catalog, Volume 3 – Edition 2019/2020

Auto

mat

ion

Tech

nolo

gy

Full L

ine

Cata

log

2019

/202

0

4

4

WAGO Electronic Interface

Full Line Catalog, Volume 4 – Edition 2019/2020

6

WAGO Marking

Full Line Catalog, Volume 6 – Edition 2019/2020

N 3/4/6

The new items in this catalog supplement products found in the following main catalogs

Volume 3Automation Technology

Volume 4WAGO Electronic Interface

Volume 6WAGO Marking

Page 3: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

Supplementary Catalog – Automation Technology and WAGO Electronic Interface

Automation Technology Volume 3

WAGO Electronic Interface Volume 4

WAGO Tools

Item Number Index

WAGO Marking Volume 6

2

90

136

126

130

Page 4: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

Volume 3 | Automation Technology www.wago.com

2 Supplementary Catalog – Automation Technology

Volume 3, Automation Technology

Description Item No. Page

SolutionsEnergy Data Management Application; Energy Data Management Visualization 2759-206/261-1000; 2759-207/271-1000 4flexROOM® Application; Weather Station Application 2759-2110/261-1000; 2759-241/261-1000 6Lighting Management Application; Lighting Management Visualization 2759-204/261-1000; 2759-210x/271-1000 8Module Type Package (MTP); e!COCKPIT MTP and MTP Library 2759-120/1121-1000; 2759-208/211-1000 10Power Plant Control Library 2759-203/211-1000 12

Softwaree!COCKPIT SVN 2759-401/1420-1000 14e!RUNTIME; Sparkplug 2759-247/211-1000 16e!RUNTIME; IEC-61131 Runtime Environment; 600 2759-216/211-1000 17e!RUNTIME; EtherCAT Master 600 2759-266/211-1000 18e!RUNTIME; BACnet/IP 300 and BACnet/IP 600 2759-x283/211-1000; 2759-x286/211-1000 19

Operation and MonitoringTouch Panel 600; Standard Line; Resistive Touchscreen; 39.6 cm (15.6”); Control Panel 762-4305/8000-002 20Touch Panel 600; Standard Line; Resistive Touchscreen; 39.6 cm (15.6”); Visu Panel 762-4205/8000-001 20Touch Panel 600; Standard Line; Resistive Touchscreen; 54.7 cm (21.5”); Control Panel 762-4306/8000-002 21Touch Panel 600; Standard Line; Resistive Touchscreen; 54.7 cm (21.5”); Visu Panel 762-4206/8000-001 21Touch Panel 600; Advanced Line; Capacitive Touchscreen; 39.6 cm (15.6”); Control Panel 762-5305/8000-002 22Touch Panel 600; Advanced Line; Capacitive Touchscreen; 39.6 cm (15.6”); Visu Panel 762-5205/8000-001 22Touch Panel 600; Advanced Line; Capacitive Touchscreen; 54.7 cm (21.5”); Control Panel 762-5306/8000-002 23Touch Panel 600; Advanced Line; Capacitive Touchscreen; 54.7 cm (21.5”); Visu Panel 762-5206/8000-001 23Touch Panel 600; Marine Line; Resistive Touchscreen; 10.9 cm (4.3”); Control Panel 762-6301/8000-002 24Touch Panel 600; Marine Line; Resistive Touchscreen; 14.5 cm (5.7”); Control Panel 762-6302/8000-002 24Touch Panel 600; Marine Line; Resistive Touchscreen; 17.8 cm (7.0”); Control Panel 762-6303/8000-002 25Touch Panel 600; Marine Line; Resistive Touchscreen; 25.7 cm (10.1”); Control Panel 762-6304/8000-002 25

ControllersController PFC200; 2nd Generation; 4 x ETHERNET 750-8210 26Controller PFC200; 2nd Generation; 2 x ETHERNET, RS-232/-485, Mobile Radio Module 4G 750-8217 27Controller PFC200; 2nd Generation; 2 x ETHERNET, RS-232/-485; BACnet/IP 750-8212/000-100 28Controller PFC200; 2nd Generation; 4 x ETHERNET; Extreme 750-8210/040-000 29Controller PFC200; 2nd Generation; 2 x ETHERNET M12, RS-232/-485; Extreme 750-8212/040-010 30Controller PFC200; 2nd Generation; 2 x ETHERNET M12, CAN, CANopen; Extreme 750-8213/040-010 31Controller EtherNet/IPTM; SD Card Slot 750-893 32Controller EtherNet/IPTM; ECO 750-823 32Controller BACnet/IP; 4th Generation; 2 x ETHERNET; SD Card Slot 750-832; 750-832/000-002 33Controller Modbus TCP; Telecontrol Technology; Ext. Temperature 750-890/025-00x 34Controller Modbus TCP; Extreme 750-890/040-000; 750-890/040-001 35

I/O System Advanced General Product Information 36

Controller PFC200; I/O System Advanced; 2 x ETHERNET 768-3301 38Fieldbus Coupler; I/O System Advanced; EtherCAT® 768-2201 398-Channel Digital Input; I/O System Advanced; 24 VDC; Fast 763-1108 4016-Channel Digital Input; I/O System Advanced; 24 VDC 763-1116 408-Channel Digital Output; I/O System Advanced; 24 VDC 0.5 A; Fast 763-1508 4116-Channel Digital Output; I/O System Advanced; 24 VDC 0.5 A 763-1516 41Supply Module; I/O System Advanced; 24 VDC; Fuse Holder 763-5101 42System Power Supply; I/O System Advanced; 24 VDC 763-5120 43750 Series Gateway; I/O System Advanced 763-4750/010-000 44End Module; I/O System Advanced 763-5600 45Accessories 763-351; 763-353; 763-354; 763-301; 249-198 46

I/O System – 750 and 753 SeriesFieldbus Coupler EtherNet/IPTM 750-363 48Fieldbus Coupler BACnet/IP; SD Card Slot 750-332 498-Channel Analog Input; Thermocouple; Adjustable 750-498 504-Channel Analog Output; Voltage/Current 750-564 51DALI-2 Release: DALI-Multi-Master 753-647 52Safe Analog Input; 4 Channels; 0/4 … 20 mA; Differential Input; PROFIsafe 750-668/000-004; 753-668/000-004 53Release: 8-Channel Digital Input; NAMUR; Intrinsically Safe 750-439 544-Channel Analog Input; RTD/TC; Intrinsically Safe 750-489 55

Page 5: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

Volume 3 | Automation Technologywww.wago.com

3Supplementary Catalog – Automation Technology

Description Item No. Page

I/O System ‒ 750 XTR SeriesFieldbus Coupler Modbus TCP; Extreme 750-362/040-000 56Fieldbus Coupler EtherNet/IPTM; Extreme 750-363/040-000 57Fieldbus Coupler Modbus TCP M12; 4th Generation; Extreme 750-364/040-010 58Fieldbus Coupler EtherNet/IPTM M12; 4th Generation; Extreme 750-365/040-010 59

I/O System Field General Product Information 60

16-Channel Digital Input; PROFINET Slave; 24 VDC; 8 x M12 Connector 765-1101/100-000 6216-Channel Digital Output; PROFINET Slave; 24 VDC; 8 x M12 Connector 765-1103/100-000 6316-Channel Digital Input/Output; PROFINET Slave; 24 VDC; 8 x M12 Connector 765-1102/100-000 648-Channel Digital Input/Output; PROFINET Slave; 24 VDC; 4 x M12 Connector 765-1104/100-000 658-Channel Digital Input/Output; PROFINET Slave; 24 VDC; 8 x M8 Connector 765-1105/100-000 658-Port IO-Link Master Class A; PROFINET; 24 VDC 2.0 A; 8 x M12 Connector 765-4101/100-000 668-Port IO-Link Master Class B; PROFINET; 24 VDC 2.0 A; 8 x M12 Connector 765-4102/100-000 674-Port IO-Link Master Class A; PROFINET; 24 VDC 2.0 A; 4 x M12 Connector 765-4103/100-000 684-Port IO-Link Master Class B; PROFINET; 24 VDC 2.0 A; 4 x M12 Connector 765-4104/100-000 698-Channel Digital Input/Output; IO-Link Class A Hub; 24 VDC 2.0 A; 4 x M12 Connector 765-1701/200-000 708-Channel Digital Input/Output; IO-Link Class B Hub; 24 VDC 2.0 A; 4 x M12 Connector 765-1704/200-000 718-Channel Digital Input/Output; IO-Link Class A Hub; 24 VDC 2.0 A; 8 x M8 Connector 765-1702/200-000 728-Channel Digital Input/Output; IO-Link Class B Hub; 24 VDC 2.0 A; 8 x M8 Connector 765-1705/200-000 7316-Channel Digital Input/Output; IO-Link Class A Hub; 24 VDC 2.0 A; 8 x M12 Connector 765-1703/200-000 7416-Channel Digital Input/Output; IO-Link Class B Hub; 24 VDC 2.0 A; 8 x M12 Connector 765-1706/200-000 75Power Cable; L-Coded; 5-Pole 76ETHERNET/PROFINET Cable; D-Coded; 4-Pole 77

Industrial SwitchesIndustrial Managed Switch; 8 Ports 1000BASE-T; 4 Slots 1000BASESX/LX; USB 852-1305/000-001 78Industrial Managed Switch; 8 Ports 1000BASE-T; 4 Slots 1000BASESX/LX; 8 * Power over Ethernet; USB 852-1505/000-001 79Industrial Managed Switch; 8 Ports 1000BASE-T; MAC Security 852-1322 80Industrial Managed Switch; 6 Ports 1000BASE-T; 2 Slots 1000BASE-SX/LX; MAC Security 852-1328 81Industrial Managed Switch; 8 Ports 100BASE-TX; PROFINET; Ext. Temperature Range 852-602 82Industrial Managed Switch; 8 Ports 100Base-TX; 2 Slots 1000Base-SX/LX; PROFINET 852-603 83Industrial Managed Switch; 8 Ports 1000Base-TX; 4 Slots 1000Base-SX/LX; PROFINET 852-1605 84

Radio TechnologyWireless ETHERNET Gateway; External Antenna 758-918/000-001 86

Accessories and ToolsmicroSD Memory Card; pSLC-NAND; 8 GB SD Memory Card; pSLC-NAND; 8 GB

758-879/000-3108758-879/000-2108

87

Room Control Unit 2852-7110 … 2852-7115 88

Manually Operated Module 2852-7510 … 2852-7516 88

DALI-2 Sensors 2852-7210, 2852-7213 … 2852-7215, 2852-7220, 2852-7230 … 2852-7233

89

Room Control Unit; Modbus®; RBG1; Display; Glass Front; Aluminum Frame 2852-7601/000-00x 89

Products highlighted in RED are new items for Spring 2020

Page 6: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

4 Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

15-minute pulse(power supply)

S0 counter,pulse counter

Current and voltagemeasurement

Flow, pressure,temperature, etc.DI

DI 3-PH MBus

AI MBus wireless

ETHERNET

Modbus TCP/UDP

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON1

23

45

67

8

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

ETHERNET

FTP(S)ETHERNET

MQTTETHERNET

HTTP(S)ETHERNET

HTTP(S)ETHERNET

HTTP(S)ETHERNET

DO Switch on and offModbusTCP/UDP

ModbusRTU

Cloud

EnOcean

WAGO Energy Data Management

Advantages:

• Ready to go in a few easy steps• No programming experience required• Integrated cloud connectivity

With our energy data management solution, you can record and visualize your measurement data from different media and with different parameters in no time. Continuous collection and monitoring provide the basis for the resource-efficient energy usage – the environment will thank you and your operating costs will be minimized. And by the way, the normative confor-mity according to DIN EN 50001 for the energetic evaluation is part of the package.WAGO Energy Data Management consists of a web-based application software combined with a modular control system.

It records measurement data from different media and influential factors for energy monitoring and processes them for further analyses, archiving and reporting. The software automatically detects different signals from the connected meters and sensors, making them available for additional energy analysis tools via simple parameter settings. This allows you to optimize energy consumption in your building or production facility, whether it’s local or across the globe.

Item DescriptionItem No.

Application Energy Data Management; Single Licen-se; Online activation 2759-206/261-1000

Visualization Energy Data Management; Single License; Online activation 2759-207/271-1000

Compatible Controllers/Touch PanelsController PFC200; G2 750-821xController PFC200; G2; XTR 750-821x/000-040Touch Panel 600 Standard Line; PIO3 762-43xx/8000-0002Touch Panel 600 Advanced Line; PIO3 762-53xx/8000-0002

A single license allows installation on one controller/Touch Panel.One license per controller/Touch Panel is required.

Delivery type License certificate by email (software available for download)

Data sheet and additional infor-mation, see:

wago.com/2759-206/261-1000wago.com/2759-207/271-1000wago.com/energy-management

The “Energy Data Management” Software is a pre-programmed application based on the e!COCKPIT Development Environment and can be used for both PFC200 G2 Controllers or Touch Panels 600.

To download the application and the license to the device, the WAGOupload software is required, which can be obtained free of charge from the WAGO homepage. An Internet connection may be required to activate the license.

Page 7: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

5Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Modbus RTU

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

EXTE XT

S1 S2 S1 S2 S1 S2 S1 S2

POWER DO L1 L2 L3 N

L1 L2 L3 N24V GND GND DO

3-PHASE POWER MEASUREMENT MODULE3x400/690V / 1A - Modbus RTUItem No.: 2857-570/024-001

µSD

PWRERRDOTxD/RxDµSD

EXTE XTS1 S2 S1 S2 S1 S2 S1 S2

POWER DO L1 L2 L3 N

L1 L2 L3 N24V GND GND DO

3-PHASE POWER MEASUREMENT MODULE3x400/690V / 1A - Modbus RTUItem No.: 2857-570/024-001

µSD

PWRERRDOTxD/RxDµSD

EXTE XT

S1 S2 S1 S2 S1 S2 S1 S2

POWER DO L1 L2 L3 N

L1 L2 L3 N24V GND GND DO

3-PHASE POWER MEASUREMENT MODULE3x400/690V / 1A - Modbus RTUItem No.: 2857-570/024-001

µSD

PWRERRDOTxD/RxDµSD

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

Modbus TCP

ETHERNET

M-BUS

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

RS-485

Energy Data Management

Required Products Description Item No.

Software LicensesWAGO Cloud; 100 license points Licenses to use the WAGO Cloud as a data collector with data visualization; the number of

required license points depends on the functions used and the data volume (for details see www.wago.com/cloud).

2759-1061/651-010WAGO Cloud; 500 license points 2759-1061/651-050WAGO Cloud; 1000 license points 2759-1061/651-100

Digital I/O Modules4-Channel Digital Input; 24 VDC; 3 ms Ex: recording the PSC effective power pulse 750-4024-Channel Digital Output; 24 VDC; 0.5 A Ex: switching outputs when alarm thresholds are reached 750-5048-Channel Digital Output; 24 VDC; 0.5 A 750-530

Analog I/O Modules Recording temperature, pressure, flow meters and other analog signals8-Channel Analog Input; Resistance measurement; Adjustable 750-4518-Channel Analog Input; 0/4 … 20 mA; Single-Ended 750-4968-Channel Analog Input; 0 … 10 VDC/±10 V; Single-Ended 750-4972-Channel Analog Input; 0 … 20 mA; Differential Input 750-4524-Channel Analog Input; Voltage/Current; Differential Input; Electrically Isolated Channels 750-471

Power Measurement Modules Power measurement directly connected to the controller3-Phase Power Measurement Module; 480 VAC; 1 A With split-core or plug-in current transformers 750-4943-Phase Power Measurement Module; 690 VAC; 1 A With split-core or plug-in current transformers 750-4953-Phase Power Measurement Module; 690 VAC; 0.5 A With split-core or plug-in current transformers 750-495/000-0013-Phase Power Measurement; 690 VAC; RTC With Rogowski coils 750-495/000-002

Communication and Technology ModulesM-Bus Master Reading in separately recorded meter readings via M-Bus 753-649RS-232/RS-485 Serial Interface Reading in data via RS-232 or RS-485 gateways (e.g., EnOcean®) 750-6522-Channel Up/Down Counter; 24 VDC; 16 Bit; 500 Hz Recording S0 and pulse counter 750-638

Power SuppliesCompact Power Supply; switched-mode; 1-phase 24 VDC output voltage; 2.5 A output current 787-1012Pro 2 Power Supply; 1- or 3-phase 24 VDC output voltage; 5 … 40 A output current 2787-2xxx

Distributed Power Measurement Modules For distributed energy acquisition via Modbus RTU3-Phase Power Measurement Module; Input: Current transformer 1 A 2857-570/024-0013-Phase Power Measurement Module; Input: Current transformer 5 A 2857-570/024-0053-Phase Power Measurement Module; Input: Rogowski Coil 2857-570/024-000

GatewaysSTC65-RS-485 EVC EnOcean® Receiver/Sender with RS-485 EVC Interface Gateway for the acquisition of EnOcean® signals 2852-7101WLAN ETHERNET Gateway; 2.4 GHz Gateway for creating wireless ETHERNET connections 758-916

Energy Data Collection with Remote Devices via Modbus RTU

The products listed below are typically used in conjunction with the “Energy Data Management” application. Detailed information about the products as well as other variants and accessories can be found in our Full Line Catalog, Volume 3 or Volume 4.

Energy Data Collection with Remote Devices via Modbus TCP

Measured Value Acquisition via M-Bus Data Acquisition via EnOcean®

Page 8: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

6 Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

1 2 3 4 5 6 7 8 9 10

ETHERNET

Weather Sensors

from Di�erent Manufacturers

System Distribution Box

Weather Station

Parameter Setting

For each room, parameters can be individually stored for lighting, shad-ing and room control. All parameters are cyclically saved either directly in the distribution box or on a separate computer via network connection. A higher-level management station accesses the distribution box parameters via the open Modbus TCP/IP protocol. This ensures that all modifications can be implemented on site or via the management station. BACnet or KNX IP systems can also be connected via Modbus TCP/IP.

Configuring – Not Programming

Each WAGO flexROOM® Distribution Box has a Web interface. Both the commissioning technician and end user can configure the controls for each room via Web browser, regardless of the user’s location and the distribu-tion box in use. Complete wall relocations, room assignments, lighting and shading groups can be changed from the parameter interface. No additional software is required.

WAGO flexROOM® ApplicationA Flexible Room Concept

Solution

Planning, commissioning and building operation must demonstrate maximum efficiency and a high degree of adaptability. Pre-configured programs and pre-defined hardware significantly streamline planning and commissioning. The more applications created within a project, the greater the benefit. Flexible building operation (e.g., conversions and room remodeling) via special maintenance levels eliminates external service costs.Install, commission and configure according to project specifications – WAGO flexROOM® com-bines these strengths into a standard module. The integrated control unit and application software are precisely tailored to room requirements.

Item DescriptionItem No.

Application flexROOM; Single License; Online activation 2759-2110/261-1000

Application Weather Station; Single License; Online activation 2759-241/261-1000

Compatible ControllersController PFC200; G2; 2ETH RS 750-8212

A single license allows installation on one controller.One license per controller is required.

Delivery type License certificate by email (software available for download)

Data sheet and additional infor-mation, see:

wago.com/2759-2110/261-1000wago.com/2759-241/261-1000wago.com/roomautomation

Both “flexROOM” and “Weather Station“ pre-programmed software appli-cations are based on the e!COCKPIT Development Environment and can be used for PFC200 G2 Controllers.

To download the application and the license to the device, the WAGOupload software is required, which can be obtained free of charge from the WAGO homepage. An Internet connection may be required to activate the license.

Page 9: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

7Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Number of Room Segments

Subsystems (Support for other subsystems upon request)

Office Areas (Segments) Special AreasInputs Outputs Inputs Outputs

DALI

SMI

EnOc

ean

KNX

Mult

i-sen

sors

(co

nven

tiona

l)

Dew

poin

t de

tect

ors

Light

ing

(DAL

I)

Sun p

rote

ctio

n (S

MI)

Heat

ing/

cool

ing

Light

switc

hes

Sunb

lind

switc

hes

Dew

poin

t de

tect

ors

Light

ing

(re

lays)

Sun p

rote

ctio

n (re

lays)

Heat

ing/

cool

ing

8 segments x x x x x 8 x x 8 - - - - - -8 segments and 4 special areas x x x x x 8 x x 8 8 4 4 4 4 416 segments x x x x x 16 x x 16 - - - - - -16 segments and 4 special areas x x x x x 16 x x 16 8 4 4 4 4 424 segments x x x x x 24 x x 24 - - - - - -24 segments and 8 special areas x x x x x 24 x x 24 16 8 8 8 8 8Note: The table displays only a portion of the different flexROOM® Distribution Box versions that are available. For more information, please visit www.flexROOM.com.

flexROOM® Application

Required Products Description Item No.

I/O SystemSerial Interface Module RS-232/RS-485 Connects to devices with a serial interface (e.g., weather sensors, EnOcean receivers) 750-652End Module Properly terminates the I/O bus 750-600Power Supply 24 VDC, 2.5 A Supplies both controllers and modules 787-1012

I/O ModulesDigital Input Modules Connect to push-buttons, switches and sensors with a potential-free contact 75x-4xx, 750-14xxDigital Output Modules Connect to digital actuators and relays 75x-5xx, 750-15xxRelay Module For lamp loads 788-354Relay Module For sunblind actuators 788-304Analog Input Modules Connect to sensors with analog output signal (0 … 10 V) 75x-4xxAnalog Output Modules Connect to actuators with analog control signal (0 … 10 V) 750-5xx

DALI

DALI Multi-Master Module Connects to a maximum of 64 DALI actuators (ECGs) and a maximum of 16 DALI multi-sen-sors (max. 64 sensor addresses) 753-647

DALI Multi-Master DC/DC Converter Supplies (24 VDC/18 VDC) one DALI Multi-Master Module 753-620Power Supply to DALI Multi-Master Supplies a maximum of five DALI Multi-Master Modules 787-1007DALI-2 Certified Sensors and other DALI Sensors DALI compatibility list available at www.wago.com/roomautomation

SMISMI Master Connects to a maximum of 16 SMI drives (230 VAC) 753-1630SMI Master LoVo Connects a max. 16 SMI low-voltage drives (24 VDC) 753-1631

EnOceanEnOcean Receiver Receiver with serial interface for EnOcean switches, sensors and room control units 2852-7101

EnOcean Repeater Improves coverage – further information on planning can be found at www.enocean.com 2852-7102

EnOcean Light Button (2-channel) For one light circuit 758-940/001-000EnOcean Light Button (4-channel) For two light circuits 758-940/003-000EnOcean Sunblind Button (2-channel) For one blind 758-940/002-000EnOcean Sunblind Button (4-channel) For two blinds 758-940/004-000

EnOcean Room Control Unit, SR04 P With integrated temperature sensor and rotary wheel for setpoint correction, for surface mounting 2852-7112

EnOcean Room Control Unit with LCD, SR06-LCD With integrated temperature sensor and buttons for setpoint correction, for 55 x 55 switch programs 2852-7113

KNXKNX TP1 Module Connects to KNX TP1 components (e.g., room control units and buttons) 753-646

The products listed below are typically used in conjunction with the flexROOM® Application. Detailed information about the products as well as other variants and accessories can be found in our Full Line Catalog, Volume 3 or Volume 4.

Advantages:

The distribution box is delivered ready to operate and can be installed directly in a suspended ceiling or a sub-floor. Room segment configuration is per-formed directly in the distribution box via standard Web browser. No expert knowledge is required to configure rooms or convert them later. Several flexROOM® Distribution Boxes can be wired into a building automation network via ETHERNET to automate a building area, a floor or an entire office section. A standard Web browser also establishes communication between the distribution boxes. If electrical distribution boxes are present, flexROOM® components can also be installed or retrofitted during facility renovation. Space conversion costs are reduced with flexROOM® because expenses are transparent and thus predictable.

Page 10: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

8 Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

ETHERNET

HCL

GPS Converter

WAGO Lighting Management Application

WAGO Lighting Management is a proven concept based on predefined hardware and preconfigured software, which greatly simplifies planning, commissioning and operation. The basic idea: WAGO Lighting Management is based on the different lighting requirements in warehouses and production facilities. For example, a production facility is divided into virtual rooms in which the light can be flexibly adapted. Each virtual room receives signals from sensors and actu-ators in order to automatically set the appropriate light intensity. By using the virtual rooms, conversions and room remodeling can be implemented quickly and simply via Web configuration. A separate HTML5 user interface is available for convenient and intuitive operation of WAGO Lighting Management. Operation is optimized for display on different end devices, such as tablets, smartphones and touch panels.

Item DescriptionItem No.

Application Lighting Management; Single License; Online activation 2759-204/261-1000

Visualization Lighting Management; Single License; Online activation

Visualization – S 1 controller 2759-2101/271-1000Visualization – M up to 3 controllers 2759-2102/271-1000Visualization – L up to 10 controllers 2759-2103/271-1000

Compatible Controllers/Touch PanelsController PFC200; G2; 2ETH RS 750-8212Touch Panel 600 Advanced Line; PIO3 762-53xx/8000-0002

A single license allows installation on one controller/Touch Panel.One license per controller/Touch Panel is required.

Delivery type License certificate by email (software available for download)

Data sheet and additional infor-mation, see:

wago.com/2759-204/261-1000wago.com/2759-210x/271-1000wago.com/lighting-management

The “Lighting Management” Software is a pre-programmed application based on the e!COCKPIT Development Environment and can be used for both PFC200 G2 Controllers or Touch Panels 600.

To download the application and the license to the device, the WAGOupload software is required, which can be obtained free of charge from the WAGO homepage. An Internet connection may be required to activate the license.

Page 11: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

9Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Lighting Management ApplicationRequired Products Description Item No.Base Unit

DALI Multi-Master In addition to 64 DALI actuators (ECGs), a DALI Multi-Master Module supports up to 16 DALI Multi-sensors (max. 64 sensor addresses); max. 10 DALI modules per base package. 753-647

End Module An end module must be snapped onto the assembly at the end of a fieldbus node. 750-600

Power Supply to I/O Node 24 VDC supply voltage for controllers and additional modules 787-1012

Power Supply to DALI Multi-Master Supplies a maximum of five DALI Multi-Master Modules 787-1007

Extension for Inputs/Push-Buttons16-Channel Digital Input; 24 VDC; 3 ms For 1–16 light push-buttons/switch inputs; max. 4 extensions per base package 750-1405

Extension for Outputs/Actuators16-Channel Digital Output; 24 VDC; 0.5 A For 1–16 actuators/lamps/relays/ECG control; max. 2 extensions per base package 750-1504

Relay socket with relay and status indicator; 1 make contact; 24 VDC Light switching via relay 788-357

Extension for EnOcean Radio

Serial Interface RS-232/-485 Serial interface connects to STC65-RS-485 EVC EnOcean Radio Transmitter/Receiver (for 1-64 rocker switches) 750-652

EnOcean Receiver/Transmitter Receives EnOcean radio signals and transmits them to the I/O node 2852-7101

EnOcean Repeater Extends the transmission range (for more planning information, visit the EnOcean website) 2852-7102

Radio Transmitter; EnOcean easyfit PTM 250;2-channel lighting control

1–2 or 1–4 signals; range of 30 meters in buildings to the radio receiver758-940/001-000

Radio Transmitter; EnOcean easyfit PTM 250;4-channel lighting control 758-940/003-000

Extension for External Time RequestReal-Time Clock Module Time synchronization module, if no time server connection is possible 750-640

GPS DCF Converter Converter/external receiver for time synchronization 2852-7901

Extension for Energy Data Measurement

3-Phase Power Measurement; 690 VAC The 750-495 3-Phase Power Measurement Module measures electrical data in a three-phase supply network. 750-495/xxx-xxx

Current and voltage connections Pre-assembled terminal block assemblies for easy connection and short-circuiting of current transformers (for current transformers, see Full Line Catalog, Volume 4) 2007-8874; 2007-8877

Extension for KNX ButtonsKNX/EIB/TP1 Interface Connects KNX buttons to the I/O node; max. 1 module per base package 753-646

Extension for SensorsDALI Sensor; PD11-BMS-FLAT LOW BAY Sensor for offices (2 … 5 m) 2852-7210

DALI Sensor; PD4-BMS-GH HIGH BAY Sensor for warehouses (5 … 16 m) 2852-7213

DALI Sensor; PD4N-BMS MID BAY Sensor for open-plan offices, underground garages, entrance halls, production facilities (2 … 10 m) 2852-7214

Adapter; AP Assembly Kit IP54 Accessories for surface mounting of the PD4N-BMS (B.E.G.) 2852-7215

DALI Sensor; MSensor G3 SRC 30 PIR 5DPI WH LOW BAY Sensor for offices (up to 5 m) 2852-7220

DALI Sensor; MSensor G3 SSM 30 10DPI WH MID BAY Sensor for high-ceiling rooms (up to 10 m) 2852-7221

DALI Sensor; IR Quattro HD DALI-2 LOW/MID BAY Sensor for offices (2.5 … 10 m) 2852-7230

DALI Sensor; IR Quattro SLIM XS DALI-2 LOW BAY Sensor for offices, slim design (2.5 … 4 m) 2852-7231

DALI Sensor; IS3360 MX HIGH BAY DALI-2 HIGH BAY Sensor for industrial buildings, circular detection range (4 … 14 m) 2852-7232

DALI Sensor; IS345 MX HIGH BAY DALI-2 HIGH BAY Sensor for industrial buildings, rectangular detection range (4 … 14 m) 2852-7233

DALI XC G3 (DALI-2) Push-button coupler connects 4 conventional push-buttons to DALI. 2852-7225

DALI SensorsDALI Multi-Sensor kit Brightness measurement and motion sensor: Kit connects to a DALI bus system. 2851-8201

DALI Sensor Coupler Sensor coupler connects MULTI-3-CI Sensors to DALI (max. 16 DALI Sensor Couplers per 753-647DALI Multi-Master) 2851-8202

DALI HIGHBAY ADAPTER + HIGH BAY Brightness measurement and motion sensor for large installation heights (3–13 meters) 2852-7207, 2852-7201

DALI HIGHBAY ADAPTER + VISION Motion sensor for large areas, open offices, hallways or warehouses 2852-7207, 2852-7202

DALI LS/PD LI Motion sensor for office lighting (1 … 5 m) 2852-7203

DALI Sensor Coupler HF LS LI + Light and recessed ceiling sensor: combined daylight and motion detection, motion detection via radar

2852-7205

Radar Sensor HF LS LI 2852-7206

4p4c Connection Cable, 50 cm 2852-7208

DALI XC Push-button coupler connects 4 conventional push-buttons to DALI. 2852-7301

DALI Sensor Coupler E Sensor coupler connects standard sensors to DALI. 2852-7204

The products listed below are typically used in conjunction with the Lighting Management Application. Detailed information about the products as well as other variants and accessories can be found in our Full Line Catalog, Volume 3 or Volume 4.

Page 12: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

10 Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Module Type Package (MTP)

Advantages:

• Simple integration of system modules into control and visualization systems• Dynamic adaptation without great engineering effort• Uniform look and feel, even with modules from different manufacturers

Modular systems are increasingly being used in manufacturing and process engineering. Fluctuating quantities and highly specialized product needs require efficient production in small quantities. In other industries as well (e.g., shipbuilding), modular systems are used where simple integration into higher-level systems for a dedicated task is the key to success.

The following requirements must be met:• Fast creation of new systems by reusing ready-made modules• Simple adaptation of existing systems to changing operating

conditions (plug & produce)• E.g., product change – requires other modules• E.g., capacity change – requires more or less modules of the same type• E.g., maintenance/repair – requires module replacement

• Standardization of interfaces

Solution: MTP

With the Module Type Package (MTP), properties of process modules are functionally described – regardless of manufacturer and technology. The self-contained modules, which can come from different manufacturers, can be easily reused and interconnected with little effort to complex overall sys-tems. The encapsulation of the functionalities within the modules reduces the dependencies among each other and thus ensures largely interfer-ence-free behaviors.

An MTP includes the following information: • Description of the data objects• Description of the control image• In the future: Description of the services, etc.

This description file can be read in and processed by higher-level systems, such as visualization or process control systems, called Process Orchestra-tion Layer (POL) in the following. Based on this information:• the variable lists/process control points can be displayed and, if necessary,

input options are offered and• the pictures can be interpreted and displayed in the respective style.

Processes can be modified without much engineering effort and production quantities can be easily adapted by adding or removing modules.

The VDI/VDE/NAMUR 2658 standard adopted jointly by NAMUR, ZVEI and VDMA is a solution to these requirements. It makes it possible to meet the increasing requirements with regard to digitalization in terms of Industry 4.0 by defining how to describe system modules and how to integrate these into the process control technology of the entire system in a standardized manner.

Item Descriptione!COCKPIT MTP; Single License; Online activation Item No.e!COCKPIT add-on license for generating MTPs, single license per PC 2759-120/1121-1000

Library MTP; Single License; Online activationLibrary license to easily create programs for modules to be exported as MTP; Single license per Controller/Touch Panel

2759-208/211-1000

Compatible Controllers/Touch PanelsController PFC200; G2 750-821xController PFC200; G2; XTR 750-821x/000-040Touch Panel 600 Standard Line* 762-4xxx/xxx-xxxTouch Panel 600 Advanced Line* 762-5xxx/xxx-xxxTouch Panel 600 Marine Line* 762-6xxx/xxx-xxx

Depending on the factory license, an additional e!RUNTIME PLC 600 license may be required.

Minimum e!COCKPIT version V1.6Delivery type License certificate by email (soft-

ware available for download) Data sheet and additional informa-tion, see:

wago.com/2759-120/1121-1000wago.com/2759-208/211-1000

An Internet connection to the PC that’s equipped with e!COCKPIT may be required for license activation.

The simple creation of the MTP at the push of a button requires the use of a library requiring a license per controller. In addition, you need a license for the engineering add-on per PC. The software itself is available for download online via e!COCKPIT, or alternatively via the download area of the WAGO homepage.

AlarmManagement

HMI MTP

Safety & Security

ProcessControl

MaintenanceDiagnostics

Page 13: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

11Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Module Type Package (MTP)Required Products Description Item No.Software Licensese!COCKPIT Engineering software license for programming both Controllers and Touch Panels;

different license forms 2759-101/1110-xxxx

e!RUNTIME; IEC 61131 runtime environment; 600 License to upgrade a Touch Panel (hardware version PIO2) to a Control Panel 2759-216/211-1000Power SuppliesCompact Power Supply; switched-mode; 1-phase

24 VDC output voltage; 2.5 A output current787-1012

Pro 2 Power Supply; 1- or 3-phase 24 VDC output voltage; 5 … 40 A output current 2787-2xxx

xx is a placeholder for the exact item number. A detailed overview can be found in our current Full Line Catalog, Volume 3.

The engineering of a system modeled with MTP occurs in two steps:

1. Module engineering (project-independent)

• Defining information technology interfaces (process control points)• Creating the control logic• Creating the control images

2. System engineering (project-related)

• Integration of the modules into the POL• Parameterization of the modules• Network engineering• Coordination and procedure control of the modules among themselves (orchestration)

WAGO offers a complete automation system consisting of a modular control system with I/O modules for almost every signal, a Touch Panel portfolio and a matching engineering system. With the “WAGO MTP Library” it is possible to automate modules, and with e!COCKPIT and an additional add-on at the push of a button, the MTP module description can be easily integrated into a wide variety of visualization and control systems.

The following products are typically used in conjunction with the Module Type Package (MTP) solution. Detailed information about the products as well as other variants and accessories can be found in our Full Line Catalog, Volume 3 or Volume 4.

MTPExportModule engineeringLi

brar

y

MTP Import System engineering

Page 14: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

12 Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Item DescriptionWAGO Power Plant Control Library Item No.Single license 2759-203/211-1000Compatible controllersController PFC200; G2; 2ETH RS; Tele; T 750-8212/025-001Controller PFC200; G2; 2ETH RS; Tele; T; ECO 750-8212/025-002Controller PFC200; G2; 2ETH RS CAN DPS; Tele; T 750-8216/025-001

A single license allows installation on one controller. One license per controller is required.

The WAGO Power Plant Control Library is an e!COCKPIT library with a control algorithm for the active and/or reactive power in energy generation plants.

The control algorithm for active and/or reactive power and corresponding setpoint specifications required by the operator can be adjusted during operation per IEC 60870 by, e.g., telecontrol technology. The controller compares the specified setpoint values with the actual values measured at the network connection point and provides the calculated correction variables for the energy generation plant.

This library can be used on second-generation PFC200 Controllers and is certified per VDE-AR-N 4110 or 4120.

The library can be used for a thirty-day trial period at no cost after which a license for the respective controller is required. The license can be separately purchased under Item Number 2759-203/211-1000.

WAGO Power Plant Control Library

Functions:

• Pfix, Qfix: Fixed active/reactive power specifications • P(f): Frequency-dependent active power regulation• P(Uoff): Active power ramp – restart after network failure• Q(P): Reactive power control per active power characteristic• Q(U): Reactive power control per voltage characteristic• Q(Udb): Reactive power control per voltage characteristic with voltage limit-

ing function • cosφfix: Fixed displacement factor specification • PSM, QSM: Slave mode, looping through the external active/reactive power

specifications

Minimum e!COCKPIT version V1.6Certification VDE-AR-N 4110 / 4120Delivery type License certificate per email Data sheet and additional information, see: wago.com/2759-203/211-1000

An Internet connection to the PC that’s equipped with e!COCKPIT may be required for license activation.

Dece

ntra

lized

En

ergy

Sup

plie

rs

SCADA Direct Sellers

Grid Connection Point

Grid

Ope

rato

rs

Setpoint Value SpecificationIEC 60870-5-104Digital, AnalogVPN Tunnel

MQTT, FTPCustomer Web Portals

Modbus RTU, TCP/IPAnalog

3-Phase Power Measurement Modules

Modbus RTU, TCP/IPAnalog/DigitalPROFIBUSCAN, CANopen

Page 15: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

13Supplementary Catalog – Automation Technology

Volume 3, Section 1 | Solutions

Page 16: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

14 Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

Minimum e!COCKPIT version V1.6.1Hard disk space 50 MBDelivery type Installation file (download)Data sheet and additional information, see: wago.com/2759-401/1420-1000

An Internet connection to your PC may be required for license activation.

Source Code Management and Revision:

The e!COCKPIT SVN add-on provides an integrated connection to the software versioning system Apache® Subversion® (SVN). SVN is a tool for version and revision control of current or historical versions of documents. This version control system tracks and controls changes to the program source code and other information stored as computer files. It is most com-monly used in software development when a team works on the same files. The add-on integrates seamlessly into the e!COCKPIT Engineering Software.

Benefits:

• Change logging: Changes can always be traced. • Compare different revisions.• Restore old revisions: Accidental changes to files can be undone at any

time. • Archive specific revisions: An older version can always be restored. • Simultaneously work in several branches of a development project.

Main Functions:

The SVN functions are integrated directly into e!COCKPIT and expand the corresponding menus and icons so that the following properties of the documents are directly visible:• Object has been added• Object with conflict• Object has been deleted• Object was changed• Normal object• Object has deleted sub-objects• Object is ignored during transfer• External object• Unversioned object

e!COCKPIT SVN

Function:

The following functions can be performed via e!COCKPIT:• Import project into Subversion®• Connect the project archive to Subversion®• Separate project from Subversion®• Check out object for editing • Transfer • Compare object

• Comparison with HEAD revision• Comparison with revision• Comparison with project on server

• Add• Integration of external files • Ignore • Subversion® info • Show properties • Show log• Undo change (to specific revision)• Update file (to specific revision)• Merge changes

Item DescriptionItem No.

e!COCKPIT SVN; Single license 2759-401/1420-1000

Single license allows installation on one computer.

Subversion® is a trademark of the Apache Software Foundation.

Page 17: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

15

ETHERNET

PLC

MQTT Sparkplug

SCADA

MQTTBroker

Item Descriptione!RUNTIME; Sparkplug Item No.Single license 2759-247/211-1000Compatible controllersPFC200; G2; 2ETH RS 750-8212PFC200; G2; 2ETH CAN 750-8213PFC200; G2; 2ETH RS CAN 750-8214PFC200; G2; 4ETH CAN USB 750-8215PFC200; G2; 2ETH RS CAN DPS 750-8216

Besides the basic controller variants listed here, the license can also be used on these controllers’ variants. For details, see the product information of the corresponding controller.For detailed information on the controllers, go to: www.wago.com/itemnumbers

Minimum e!COCKPIT version V1.5.0Minimum firmware version 12Delivery type License certificate via email

(e!COCKPIT already contains the software itself)

Data sheet and further information, see: wago.com/2759-247/211-1000

An Internet connection to the PC with the e!COCKPIT installation may be required for license activation.The single license allows installation on one controller. One license per controller is required.

Function

MQTT is a powerful MQTT protocol that has become standard in many industrial automation applications. WAGO’s PFC200 Controller (second generation) supports the MQTT protocol and the Sparkplug specification that defines both topic and payload, allowing the controller to exchange data directly with Sparkplug-enabled systems (e.g., SCADA). This requires a license for the controller.

Configuration is performed via the controller’s Web-based management and the variables to be transmitted or received are defined by the e!COCKPIT Engineering Software and its library.

Runtime Software e!RUNTIME; Sparkplug

Advantages:

• The PFC200 communicates directly with Sparkplug-enabled systems (e.g., SCADA) without requiring any additional gateway.

Installation:

• Enter the licence into e!COCKPIT, assign it to a controller and load both license and project into the controller. No other installation steps are required.

Technical Data:

• Sparkplug B payload• Publish data• Subscribe to data

Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

Page 18: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

16

ETHERNET

PLC

Fieldbus

Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

Item Descriptione!RUNTIME; IEC 61131 runtime environment; 600 Item No.Single license 2759-216/211-1000Compatible Touch PanelsTouch Panel 600 Standard Line; PIO2 762-42xx/8000-0001Touch Panel 600 Advanced Line; PIO2 762-52xx/8000-0001Touch Panel 600 Marine Line; PIO2 762-62xx/8000-0001

xx is a wildcard; the license applies to all Touch Panel sizes.

Minimum e!COCKPIT version V1.5.1Delivery type License certificate via email

(e!COCKPIT already contains the software itself)

Data sheet and additional information, see: wago.com/2759-216/211-1000

An Internet connection to the PC that’s equipped with e!COCKPIT may be required for license activation.A single license allows installation on one device. One license per device is required.

Function:

This license allows a properly prepared device to expand into a programmable logic controller (PLC). A PLC is a device in which logical connections and operations are programmed, typically in graphical or textual languages adhering to IEC 61131-3. This can be either a device in a standard housing for control cabinet installation or a device with a completely different form factor (e.g., a touch panel).

The e!COCKPIT Engineering Software is used for programming, which in addition to pure programming is also responsible for configuring devices and creating visualization projects.

Technical Data:

• PLC functionality per IEC 61131-3• Performance dependent on target platform• Multitasking operation

Runtime Software e!RUNTIME; IEC 61131 runtime environment; 600

Advantages:

• Controlling processes• Reading in data via a fieldbus• Very compact automation solutions by combining several functions into one

device (e.g., controlling and visualizing)

Installation:

Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the device. No other installation steps are required.

Programming:

Programming the control function may also be performed in different graphical or textual programming languages.

TextualInstruction List Structured Text

LD VAR_1 Load value of Var_1AND %IX1.0 AND input 1.0OR %QX2.1 OR output 2.1ST Var_4 Save result in Var_4

IF Bed1 THENZ := -1;ELSEZ := 1

END_IF

Graphical

Ladder Diagram Function Block Sequential Function Chart

&

Page 19: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

17

ETHERNET

EtherCAT

PLC

Item Descriptione!RUNTIME EtherCAT Master 600 Item No.Single license 2759-266/211-1000Compatible devicesHardware configuration PIO3

Touch Panel 600 Standard Line 762-43xx/8000-0002Touch Panel 600 Advanced Line 762-53xx/8000-0002

Hardware configuration PIO2

Touch Panel 600 Standard Line *) 762-42xx/8000-0001Touch Panel 600 Advanced Line *) 762-52xx/8000-0001Touch Panel 600 Marine Line *) 762-62xx/8000-0001

xx is a wildcard; the license applies to all Touch Panel sizes.

*) The prerequisite for using the EtherCAT Master is the license equipment of the device with a PLC license as Control Panel.

Minimum e!COCKPIT version V1.5.1Delivery type License certificate via email

(e!COCKPIT already contains the software itself)

Data sheet and additional information, see: wago.com/2759-266/211-1000

An Internet connection to the PC that’s equipped with e!COCKPIT may be required for license activation.Single license allows installation on one device. One license per device is required.

EtherCAT® is a registered trademark and patented technology of Beckhoff Automation GmbH.

Function:

EtherCAT is a powerful real-time ETHERNET fieldbus system that has become standard in many industrial automation applications. Some WAGO devices can be operated as EtherCAT Masters. This requires a license.

The EtherCAT system is configured via special configuration dialogs in the e!COCKPIT Engineering Software. These specify: • That the device should function as an EtherCAT Master • What field devices should be addressed• What form the topology of the network takes• What parameter values should be sent to the slaves upon startup

Besides the protocol stack in the form of a library, the runtime system also provides components for direct access to the ETHERNET interface and diagnostics.

Runtime Software e!RUNTIME EtherCAT Master 600

Advantages:

• Using the device as an EtherCAT Master• Controlling WAGO slaves with the EtherCAT fieldbus system,

e.g., the EtherCAT fieldbus coupler of the WAGO-I/O-SYSTEM 750• Controlling additional field devices, which can be declared in e!COCKPIT via

a standardized device description

Installation:

Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the device. No other installation steps are required.

Technical Data:

• Distributed clocks• Hot connect• Bus diagnostics: In the configurator and with the PLC application• Supported layer 7 protocols:

• CoE (CANopen / CAN over EtherCAT) • FoE (File over EtherCAT), • VoE (Vendor over EtherCAT)

Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

Page 20: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

18 Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

ETHERNET

PLC

BACnet

12

34

56

78

ON

PLC

BACnet

Con�gurator

B-OWS

Management

Station

Web-Visu

e!RUNTIME;

BACnet/IP; 300 e!RUNTIME;

BACnet/IP; 600

Function:

“Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies communication between products from different manufacturers.The PFC200 Controller (2nd generation) or WAGO Touch Panel can be op-erated as a BACnet building controller and supports the B-BC device profile with all major BACnet objects and interoperability building blocks (BIBBs).The devices communicate via BACnet/IP and offer the functionality of a BACnet client and BACnet server.

To use BACnet/IP, it is necessary to equip the device with a license.

The BACnet network is configured using the WAGO BACnet Configurator and the e!COCKPIT Engineering Software.

Runtime Software e!RUNTIME; BACnet/IP

Benefits:

• Use the device as a BACnet Building Controller (B-BC)• Control and detect distributed I/O signals from WAGO BACnet/IP Couplers

via BACnet fieldbus protocol• Data exchange with other BACnet devices as a BACnet client or server

Installation:

Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the controller. No other steps are required.

Technical Data:

See “Protocol Implementation Conformance Statement” (PICS)

Item Description Features Item No.e!RUNTIME; BACnet/IP; 300; Single license

without limitation of the BACnet objects* 2759-283/211-1000

e!RUNTIME; BACnet/IP; 300; M; Single license

up to 256 BACnet objects 2759-2283/211-1000

Compatible controllersController PFC200; G2; 2ETH RS 750-8212Controller PFC200; G2; 2ETH RS; T 750-8212/025-000Controller PFC200; G2; 2ETH CAN 750-8213

Item Description Features Item No.e!RUNTIME; BACnet/IP; 600; Single license

without limitation of the BACnet objects* 2759-286/211-1000

e!RUNTIME; BACnet/IP; 600; M; Single license

up to 256 BACnet objects 2759-2286/211-1000

Compatible devicesTouch Panel 600 Standard Line; Hardware Configuration PIO 3 762-43xx/8000-002

Touch Panel 600 Advanced Line; Hardware Configuration PIO 3 762-53xx/8000-002

*Number of BACnet objects: without limitation – but depends on the appli-cation used

Minimum firmware version Firmware (16)Minimum e!COCKPIT version V1.6.1Delivery type License certificate via email

(e!COCKPIT already contains the software itself)

Data sheet and additional information, see:

wago.com/2759-283/211-1000wago.com/2759-286/211-1000

An Internet connection to the PC that’s equipped with e!COCKPIT may be required for license activation.A single license allows installation on one device. One license per device is required.

BACnet® is a registered trademark of the American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. (ASHRAE).

Page 21: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

19Supplementary Catalog – Automation Technology

Volume 3, Section 2 | Software

Page 22: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

20 Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Touch Panel 600 Standard Line; Resistive Touchscreen; 39.6 cm (15.6″)

Item Description Touch Panel; 39.6 cm (15.6”); 1920 x 1080 pixels; Resistive touchscreenVersion Hardware configuration PIO3; Control Panel Hardware configuration PIO2; Visu PanelItem No. 762-4305/8000-002 762-4205/8000-001

Order Text TP600; 15.6; 1920x1080; PIO3; CP TP600; 15.6; 1920x1080; PIO2; VP

Technical DataDisplay/front view Resistive touchscreenScreen size (diagonal) 39.6 cm (15.6″)Contrast ratio 800:1Graphics resolution 1920 x 1080Viewing angle (horizontal/vertical) 85° / 85°Brightness 500 cd/m²Communication EtherNet/IPTM Adapter (Slave), Library for e!RUNTIME1); Modbus TCP Master/Slave1);

EtherCAT® Master, requires an additional license1)

CANopen; Modbus (UDP); RS-232/-485 Interface; MQTT

ETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch)Processor Cortex A9, 1 GHzMain memory (RAM)/internal memory (flash) 2 GB / 4 GBProgram memory/data memory/non-volatile memory (software)

60 MB* / 60 MB* / 128 KB 60 MB* / 60 MB* / -*For memory configuration via e!RUNTIME, the program and data memory together have a maximum

size of 60 MB and can be distributed dynamically.Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB)RTC (Real-Time Clock) Maintenance-free, buffering min. 6 weeksInterfaces (USB) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable AudioDimensions (W x H x D) 420 x 283 x 78 mm 420 x 283 x 58 mmPanel cutout (W x H) 406 x 268 mmFront panel Anodized aluminum; polyester filmHousing material Anodized aluminumMounting Clamping elements (included) or VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %) with reverse voltage protectionInput current (24 V) 430 mA; without USB load 450 mA; without USB loadOperating power 10.3 W; without USB load 10.8 W; without USB loadSurrounding air temperature (operation) 0 … +55 °CProtection class IP65 (front side); IP20 (rear side), per EN 60529

Approvals 1Data sheet and additional information, see: wago.com/762-4305/8000-002 wago.com/762-4205/8000-001

Accessories Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108Clamping elements (included) 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included 2759-216/211-1000e!RUNTIME; EtherCAT® Master 600 2759-266/211-1000

1) Prerequisite is the e!RUNTIME license; IEC-61131 runtime environment; 600

Page 23: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

21Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Touch Panel 600 Standard Line; Resistive Touchscreen; 54.7 cm (21.5″)

Item Description Touch Panel; 54.7 cm (21.5”); 1920 x 1080 pixels; Resistive touchscreenVersion Hardware configuration PIO3; Control Panel Hardware configuration PIO2; Visu PanelItem No. 762-4306/8000-002 762-4206/8000-001

Order Text TP600; 21.5; 1920x1080; PIO3; CP TP600; 21.5; 1920x1080; PIO2; VP

Technical DataDisplay/front view Resistive touchscreenScreen size (diagonal) 54.7 cm (21.5″)Contrast ratio 1000:1Graphics resolution 1920 x 1080Viewing angle (horizontal/vertical) 89° / 89°Brightness 350 cd/m²Communication EtherNet/IPTM Adapter (Slave), Library for e!RUNTIME1); Modbus TCP Master/Slave1);

EtherCAT® Master, requires an additional license1)

CANopen; Modbus (UDP); RS-232/-485 Interface; MQTT

ETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch)Processor Cortex A9, 1 GHzMain memory (RAM)/internal memory (flash) 2 GB / 4 GBProgram memory/data memory/non-volatile memory (software)

60 MB* / 60 MB* / 128 KB 60 MB* / 60 MB* / -*For memory configuration via e!RUNTIME, the program and data memory together have a maximum

size of 60 MB and can be distributed dynamically.Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB)RTC (Real-Time Clock) Maintenance-free, buffering min. 6 weeksInterfaces (USB) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable AudioDimensions (W x H x D) 554 x 358 x 78 mm 554 x 358 x 58 mmPanel cutout (W x H) 540 x 344 mmFront panel Anodized aluminum; polyester filmHousing material Anodized aluminumMounting Clamping elements (included) or VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %) with reverse voltage protectionInput current (24 V) 330 mA; without USB load 350 mA; without USB loadOperating power 7.9 W; without USB load 8.4 W; without USB loadSurrounding air temperature (operation) 0 … +55 °CProtection class IP65 (front side); IP20 (rear side), per EN 60529

Approvals 1Data sheet and additional information, see: wago.com/762-4306/8000-002 wago.com/762-4206/8000-001

Accessories Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108Clamping elements (included) 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included 2759-216/211-1000e!RUNTIME; EtherCAT® Master 600 2759-266/211-1000

1) Prerequisite is the e!RUNTIME license; IEC-61131 runtime environment; 600

Page 24: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

22 Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Touch Panel 600 Advanced Line; Capacitive Touchscreen with a Glass Surface; 39.6 cm (15.6”)

Item Description Touch Panel; 39.6 cm (15.6”); 1920 x 1080 pixels; Capacitive touchscreen with a glass surfaceVersion Hardware configuration PIO3; Control Panel Hardware configuration PIO2; Visu PanelItem No. 762-5305/8000-002 762-5205/8000-001

Order Text TP600; 15.6; 1920x1080; PIO3; CP TP600; 15.6; 1920x1080; PIO2; VP

Technical DataDisplay/front view Multitouch glass front; Capacitive touchscreen with a glass surfaceScreen size (diagonal) 39.6 cm (15.6″)Contrast ratio 800:1Graphics resolution 1920 x 1080Viewing angle (horizontal/vertical) 85° / 85°Brightness 500 cd/m²Communication EtherNet/IPTM Adapter (Slave), Library for e!RUNTIME1); Modbus TCP Master/Slave1);

EtherCAT® Master, requires an additional license1)

CANopen; Modbus (UDP); RS-232/-485 Interface; MQTT

ETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch)Processor Cortex A9, 1 GHzMain memory (RAM)/internal memory (flash) 2 GB / 4 GBProgram memory/data memory/non-volatile memory (software)

60 MB* / 60 MB* / 128 KB 60 MB* / 60 MB* / -*For memory configuration via e!RUNTIME, the program and data memory together have a maximum

size of 60 MB and can be distributed dynamically.Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB)RTC (Real-Time Clock) Maintenance-free, buffering min. 6 weeksInterfaces (USB) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable AudioDimensions (W x H x D) 420 x 283 x 78 mm 420 x 283 x 58 mmPanel cutout (W x H) 406 x 268 mmFront panel Anodized aluminum; glassHousing material Anodized aluminumMounting Clamping elements (included) or VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %) with reverse voltage protectionInput current (24 V) 430 mA; without USB load 450 mA; without USB loadOperating power 10.3 W; without USB load 10.8 W; without USB loadSurrounding air temperature (operation) 0 … +55 °CProtection class IP65 (front side); IP20 (rear side), per EN 60529

Approvals 1Data sheet and additional information, see: wago.com/762-5305/8000-002 wago.com/762-5205/8000-001

Accessories Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108Clamping elements (included) 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included 2759-216/211-1000e!RUNTIME; EtherCAT® Master 600 2759-266/211-1000

1) Prerequisite is the e!RUNTIME license; IEC-61131 runtime environment; 600

Page 25: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

23Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Touch Panel 600 Advanced Line; Capacitive Touchscreen with a Glass Surface; 54.7 cm (21.5”)

Item Description Touch Panel; 54.7 cm (21.5”); 1920 x 1080 pixels; Capacitive touchscreen with a glass surfaceVersion Hardware configuration PIO3; Control Panel Hardware configuration PIO2; Visu PanelItem No. 762-5306/8000-002 762-5206/8000-001

Order Text TP600; 21.5; 1920x1080; PIO3; CP TP600; 21.5; 1920x1080; PIO2; VP

Technical DataDisplay/front view Multitouch glass front; Capacitive touchscreen with a glass surfaceScreen size (diagonal) 54.7 cm (21.5″)Contrast ratio 1000:1Graphics resolution 1920 x 1080Viewing angle (horizontal/vertical) 89° / 89°Brightness 350 cd/m²Communication EtherNet/IPTM Adapter (Slave), Library for e!RUNTIME1); Modbus TCP Master/Slave1);

EtherCAT® Master, requires an additional license1)

CANopen; Modbus (UDP); RS-232/-485 Interface; MQTT

ETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch)Processor Cortex A9, 1 GHzMain memory (RAM)/internal memory (flash) 2 GB / 4 GBProgram memory/data memory/non-volatile memory (software)

60 MB* / 60 MB* / 128 KB 60 MB* / 60 MB* / -*For memory configuration via e!RUNTIME, the program and data memory together have a maximum

size of 60 MB and can be distributed dynamically.Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB)RTC (Real-Time Clock) Maintenance-free, buffering min. 6 weeksInterfaces (USB) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable AudioDimensions (W x H x D) 554 x 358 x 78 mm 554 x 358 x 58 mmPanel cutout (W x H) 540 x 344 mmFront panel Anodized aluminum; glassHousing material Anodized aluminumMounting Clamping elements (included) or VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %) with reverse voltage protectionInput current (24 V) 330 mA; without USB load 350 mA; without USB loadOperating power 7.9 W; without USB load 8.4 W; without USB loadSurrounding air temperature (operation) 0 … +55 °CProtection class IP65 (front side); IP20 (rear side), per EN 60529

Approvals 1Data sheet and additional information, see: wago.com/762-5306/8000-002 wago.com/762-5206/8000-001

Accessories Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108Clamping elements (included) 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included 2759-216/211-1000e!RUNTIME; EtherCAT® Master 600 2759-266/211-1000

1) Prerequisite is the e!RUNTIME license; IEC-61131 runtime environment; 600

Page 26: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

24 Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Touch Panel 600 Marine Line; Resistive Touchscreen; 10.9 cm (4.3”) or 14.5 cm (5.7”)

Item Description Touch Panel; 10.9 cm (4.3”); 480 x 272 pixels; Resistive touchscreen; Marine version

Touch Panel; 14.5 cm (5.7”); 640 x 480 pixels; Resistive touchscreen; Marine version

Version Hardware configuration PIO3; Control Panel Hardware configuration PIO3; Control PanelItem No. 762-6301/8000-002 762-6302/8000-002

Order Text TP600; 4.3; 480x272; PIO3; CP TP600; 5.7; 640x480; PIO3; CP

Technical DataDisplay/front view Resistive touchscreen (black front) Resistive touchscreen (black front)Screen size (diagonal) 10.9 cm (4.3”) 14.5 cm (5.7”)Aspect 16:9 4:3Display colors 16 million 262.000Graphics resolution 480 x 272 640 x 480Control elements Two brightness settings (High and Low) on the

frontTwo brightness settings (High and Low) on the

frontCommunication with e!RUNTIME PLC 600 license

EtherNet/IPTM adapter (slave), library for e!RUN-TIME; Modbus TCP master/slave;

EtherCAT master, requires an additional license

EtherNet/IPTM adapter (slave), library for e!RUN-TIME; Modbus TCP master/slave;

EtherCAT master, requires an additional licenseCommunication CANopen; Modbus (UDP); RS-232/-485 interface;

MQTTCANopen; Modbus (UDP); RS-232/-485 interface;

MQTTETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSH DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3) e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch) Real-time Linux (with RT-Preempt patch)Processor Cortex A9 Cortex A9Main memory (RAM)/internal memory (flash) 2 GB / 4 GB 2 GB / 4 GBProgram/data memory 60 MB / 60 MB / 128 KB;

for memory configuration via e!RUNTIME, the pro-gram and data memory together have a maximum size of 60 MB and can be distributed dynamically.

60 MB / 60 MB / 128 KB; for memory configuration via e!RUNTIME, the pro-gram and data memory together have a maximum size of 60 MB and can be distributed dynamically.

Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB) microSD (max. 2 GB); microSDHC (max. 32 GB)Interfaces (USB) 2 x USB host 2.0 (type A) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable Audio; 4 x DIO, configurableDimensions (W x H x D) 155 x 135 x 78 mm 172 x 163 x 78 mmPanel cutout (W x H) 140 x 120 mm 157 x 148 mmMounting Clamping elements (included) or

VESA mount (4 x M4x8)Clamping elements (included) or

VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %);

with reverse voltage protection24 VDC, SELV (−25 ... +30 %);

with reverse voltage protectionSurrounding air temperature (operation) 0 … +55 °C 0 … +55 °C

Approvals 1; r OrdLoc 1; r OrdLocApprovals (pending) DNV GL DNV GLData sheet and additional information, see: wago.com/762-6301/8000-002 wago.com/762-6302/8000-002

Accessories Item No. Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102 758-879/000-3102

microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108 758-879/000-3108Clamping elements (included) 762-9001 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included Includede!RUNTIME; EtherCAT® Master 600 2759-266/211-1000 2759-266/211-1000

Page 27: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

25Supplementary Catalog – Automation Technology

Volume 3, Section 3 | Operation and Monitoring

Item Description Touch Panel; 17.8 cm (7.0”); 800 x 480 pixels; Resistive touchscreen; Marine version

Touch Panel; 25.7 cm (10.1”); 1280 x 800 pixels; Resistive touchscreen; Marine version

Version Hardware configuration PIO3; Control Panel Hardware configuration PIO3; Control PanelItem No. 762-6303/8000-002 762-6304/8000-002

Order Text TP600; 7.0; 800x480; PIO3; CP TP600; 10.1; 1280x800; PIO3; CP

Technical DataDisplay/front view Resistive touchscreen (black front) Resistive touchscreen (black front)Screen size (diagonal) 18 cm (7.0″) 25.7 cm (10.1″)Aspect 16:9 16:9Display colors 16 million 16 millionGraphics resolution 800 x 480 1280 x 800Control elements Two brightness settings (High and Low) on the

frontTwo brightness settings (High and Low) on the

frontCommunication with e!RUNTIME PLC 600 license

EtherNet/IPTM adapter (slave), library for e!RUN-TIME; Modbus TCP master/slave;

EtherCAT master, requires an additional license

EtherNet/IPTM adapter (slave), library for e!RUN-TIME; Modbus TCP master/slave;

EtherCAT master, requires an additional licenseCommunication CANopen; Modbus (UDP); RS-232/-485 interface;

MQTTCANopen; Modbus (UDP); RS-232/-485 interface;

MQTTETHERNET protocols DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSH DHCP; DNS; FTP; FTPS; HTTP; HTTPS; SSHProgramming environment e!COCKPIT (based on CODESYS V3) e!COCKPIT (based on CODESYS V3)Operating system Real-time Linux (with RT-Preempt patch) Real-time Linux (with RT-Preempt patch)Processor Cortex A9 Cortex A9Main memory (RAM)/internal memory (flash) 2 GB / 4 GB 2 GB / 4 GBProgram/data memory 60 MB / 60 MB / 128 KB;

for memory configuration via e!RUNTIME, the pro-gram and data memory together have a maximum size of 60 MB and can be distributed dynamically.

60 MB / 60 MB / 128 KB; for memory configuration via e!RUNTIME, the pro-gram and data memory together have a maximum size of 60 MB and can be distributed dynamically.

Memory expansion microSD (max. 2 GB); microSDHC (max. 32 GB) microSD (max. 2 GB); microSDHC (max. 32 GB)Interfaces (USB) 2 x USB host 2.0 (type A) 2 x USB host 2.0 (type A)Onboard I/Os Audio; 4 x DIO, configurable Audio; 4 x DIO, configurableDimensions (W x H x D) 213 x 167 x 78 mm 293 x 223 x 78 mmPanel cutout (W x H) 198 x 152 mm 278 x 208 mmMounting Clamping elements (included) or

VESA mount (4 x M4x8)Clamping elements (included) or

VESA mount (4 x M4x8)Supply voltage 24 VDC, SELV (−25 ... +30 %);

with reverse voltage protection24 VDC, SELV (−25 ... +30 %);

with reverse voltage protectionSurrounding air temperature (operation) 0 … +55 °C 0 … +55 °C

Approvals 1; r OrdLoc 1; r OrdLocApprovals (pending) DNV GL DNV GLData sheet and additional information, see: wago.com/762-6303/8000-002 wago.com/762-6304/8000-002

Accessories Item No. Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108 758-879/000-3108Clamping elements (included) 762-9001 762-9001

e!RUNTIME; IEC-61131 Runtime Environment; 600 Included Includede!RUNTIME; EtherCAT® Master 600 2759-266/211-1000 2759-266/211-1000

Touch Panel 600 Marine Line; Resistive Touchscreen; 17.8 cm (7.0”) or 25.7 cm (10.1”)

Page 28: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

26 Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

750-

8210

ACT

ACT

LNK

ETHLN

KX1

1X1

2

U6U5U4U3U2U1

SYSRUNI/OMSNSU7

RST

RUNSTOPRESET

SD

A

B

ACT

ACT

LNK

ETHLN

KX1

X2

24V 0V

+ +

— —

01 02

Fieldbus connection2 x RJ-45 (switched)

Fieldbus connection2 x RJ-45 (switched)

SD memory card slot

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

PFC200 Controller; 2nd Generation; 4 x ETHERNET

Item Description PFC200 Controller; 2nd Generation; 4 x ETHERNETVersion Standard Ext. temperatureItem No. 750-8210 750-8210/025-000Order Text PFC200; G2; 4ETH PFC200; G2; 4ETH; T

Technical DataCommunication Modbus (TCP, UDP, RTU); EtherNet/IPTM adapter (slave), library for e!RUNTIME; MQTT;

Telecontrol protocols (requires an additional license on the device)ETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHTelecontrol protocols IEC 60870-5-101/-103/-104; IEC 61850-7-4; IEC 61400-25; DNP3Connection technology: fieldbus input/output 4 x RJ-45Baud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3); e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

16 MB / 64 MB / 128 KB; for memory configuration via e!RUNTIME, the program and data memory together have a maximum size

of 60 MB and can be distributed dynamically.Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 words; configuring via e!RUNTIME: 32,000 words / 32,000 wordsSupply voltage (system) 24 VDC (−25 … 30 %); via wiring level (CAGE CLAMP® connection)Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 1700 mASurrounding air temperature (operation) 0 … +55 °C −20 … +60 °CDimensions W x H x D 78.6 x 100 x 64.7 mm

Approvals 1Data sheet and additional information, see: wago.com/750-8210

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

Page 29: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

27Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

24V 0V

+ +

— —

RUNSTOPRESET

SYS RSTRUNI/OMSNSUSR

SD

ACT

ACT

LNK

ETHLN

KX3

RS23

2/48

5X1

X2

CON

SIM

ANT

A

B

01 02

NETWDS

750-

8217

Serial interface

SD memory card slotSIM card slot

Antenna connection

Fieldbus connection2 x RJ-45 (switched)

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

PFC200 Controller; 2nd Generation; 2 x ETHERNET, RS232/-485, Mobile Radio Module 4G

Item Description PFC200 Controller; 2nd Generation; 2 x ETHERNET, RS232/-485, Mobile Radio Module 4GVersion Standard Ext. temperatureItem No. 750-8217 750-8217/025-000Order Text PFC200; G2; 2ETH RS; 4G PFC200; G2; 2ETH RS; 4G; T

Technical DataCommunication Modbus (TCP, UDP, RTU); EtherNet/IPTM adapter (slave), library for e!RUNTIME; MQTT;

Telecontrol protocols (requires an additional license on the device); RS-232/-485 interfaceETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHTelecontrol protocols IEC 60870-5-101/-103/-104; IEC 61850-7-4; IEC 61400-25; DNP3Radio technology GSM/Edge/UMTS/HSPA+; LTELTE category Cat. 4 (150 Mbps (DL) / 50 Mbps (UL))Frequency band GSM dual band (B3; B8); E-UTRA bands (B1; B3; B5; B7; B8; B20; B38; B40; B41)Services SMS (bidirectional); GPRS connection to InternetSecurity encryption OpenVPN; IPsec; firewallVisualization Web-VisuProgramming e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

16 MB / 64 MB / 128 KB; For memory configuration via e!RUNTIME, the program and data memory together have a maximum size

of 60 MB and can be distributed dynamically.Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 wordsSupply voltage (system) 24 VDC (−25 … 30 %); via wiring level (CAGE CLAMP® connection)Supply voltage (field) 24 VDC (−25 … 30 %); incoming via wiring level (CAGE CLAMP® connection); 24 VDC; outgoing via power

jumper contactsInput current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 700 mASurrounding air temperature (operation) 0 … +55 °C −20 … +60 °CDimensions W x H x D 102.5 x 100 x 71.9 mm

Approvals 1Data sheet and additional information, see: wago.com/750-8217

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108Antenna; GSM 758-965

Page 30: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

28

Controller PFC200; BACnet/IP

Item Description Controller PFC200; 2nd generation; 2 x ETHERNET; RS-232/-485; BACnet/IPVersion StandardItem No. 750-8212/000-100Order Text PFC200; G2; 2ETH RS; BACnet/IP

Technical DataCommunication BACnet/IP; Modbus (TCP, UDP, RTU); RS-232/-485 interfaceETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHBACnet/IP protocol ISO 16484-5

BACnet device profile B-BC (BACnet Building Controller)BACnet revision 14

Visualization Web-VisuProgramming e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

60 MB / 60 MB / 128 KB; for memory configuration via e!RUNTIME, the program and data memory together have a maximum size

of 60 MB and can be distributed dynamically.Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 32,000 words / 32,000 wordsSupply voltage (system) 24 VDC (−25 … 30 %); via wiring level (CAGE CLAMP® connection)Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 1700 mASurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 78.6 x 71.9 x 100 mm

Approvals 1BACnet approvals WSPCert certification: Pending; BTL listing: PendingData sheet and further information, see: wago.com/750-8212/000-100

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108BACnet Configurator Download: www.wago.com

U6U5U4U3

RUNSTOPRESET

U2U1

SYS RSTRUNI/OMS/BTNSU7

750-

8212

/000

-100

SD

24V 0V

+ +

— —

ACT

ACT

LNK

ETHLN

KX3

RS23

2/48

5X1

X2

A

B

01 02

Serial interface

Fieldbus connection2 x RJ-45 (switched)

SD memory card slot

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

Page 31: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

29Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

750-

8210

/040

-000

ACT

ACT

LNK

ETHLN

KX1

1X1

2

U6U5U4U3U2U1

SYSRUNI/OMSNSU7

RST

RUNSTOPRESET

SD

ACT

ACT

LNK

ETHLN

KX1

X2

ABCD

24V 0V

+ +

— —

01 02

Fieldbus connection2 x RJ-45 (switched)

Fieldbus connection2 x RJ-45 (switched)

SD memory card slot

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

PFC200 Controller; 2nd Generation; 4 x ETHERNET; Extreme

Item Description PFC200 Controller; 2nd Generation; 4 x ETHERNETVersion ExtremeItem No. 750-8210/040-000Order Text PFC200; G2; 4ETH; XTR

Technical DataCommunication Modbus (TCP, UDP, RTU); EtherNet/IPTM adapter (slave), library for e!RUNTIME; MQTT;

Telecontrol protocols (requires an additional license on the device)ETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHTelecontrol protocols IEC 60870-5-101/-103/-104; IEC 61850-7-4; IEC 61400-25; DNP3Connection technology: fieldbus input/output 4 x RJ-45Baud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3); e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

16 MB / 64 MB / 128 KB; For memory configuration via e!RUNTIME, the program and data memory together have a maximum size

of 60 MB and can be distributed dynamically.Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 words; configuring via e!RUNTIME: 32000 words / 32000 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power

jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 78.6 x 100 x 64.7 mm

Approvals 1Data sheet and additional information, see: wago.com/750-8210/040-000

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

Page 32: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

30 Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

Controller PFC200 G2; 2 x ETHERNET M12, RS-232/485; Extreme

Item Description Controller PFC200 G2; 2 x ETHERNET M12, RS-232/-485Version ExtremeItem No. 750-8212/040-010Order Text PFC200 G2 2ETH M12 RS; XTR

Technical DataCommunication Modbus (TCP, UDP, RTU); RS-232/485 interfaceETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHConnection technology: fieldbus input/output Modbus TCP/UDP: 2 x D-coded M12 socket; Modbus RTU; RS-232/485 interfaceBaud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3); e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

16 MB / 64 MB / 128 KB; for memory configuration via e!RUNTIME, the program and data memory together have a maximum size

of 60 MB and can be distributed dynamically.Number of modules per node (max.) 64Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 words; configuring via e!RUNTIME: 32,000 words / 32,000 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power

jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 112 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLocApprovals (pending) 4 ATEX/IECExData sheet and additional information, see: wago.com/750-8212/040-010

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

U6U5U4U3

RUNSTOP

RESET

U2U1

SYS RSTRUNI/OMSNSU7

750-

8212

/040

-010

SD

X3 RS

232/4

85

ETH

X2

ETH

X1

ABCD

24V 0V

+ +

— —

01 02

Fieldbus connectionETHERNET M12

Fieldbus connectionETHERNET M12

Serialinterface

SD card slot

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Page 33: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

31Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

Controller PFC200 G2; 2 x ETHERNET M12, CAN, CANopen; Extreme

Item Description Controller PFC200 G2; 2 x ETHERNET M12, CAN, CANopenVersion ExtremeItem No. 750-8213/040-010Order Text PFC200 G2 2ETH M12 CAN; XTR

Technical DataCommunication Modbus (TCP, UDP); CANopenETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHConnection technology: fieldbus input/output Modbus TCP/UDP: 2 x D-coded M12 socket; CANopen: 1 x D-Sub 9 plugBaud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3); e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 128 KB

Program memory/data memory/non-volatile memory (software)

16 MB* / 64 MB* / 128 KB *For memory configuration via e!RUNTIME, the program and data memory together have a maximum

size of 60 MB and can be distributed dynamically.Number of modules per node (max.) 64Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 words; configuring via e!RUNTIME: 32,000 words / 32,000 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power

jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 550 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 112 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLocApprovals (pending) 4 ATEX/IECExData sheet and additional information, see: wago.com/750-8213/040-010

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

U6U5U4U3

RUNSTOP

RESET

U2U1

SYS RSTRUNI/OMSNSCAN

750-

8213

/040

-010

SD

ETH

X2

ETH

X1

X3 CA

N

ABCD

24V 0V

+ +

— —

01 02

Fieldbus connectionETHERNET M12

Fieldbus connectionETHERNET M12

Fieldbus connectionCAN, CANopen

SD card slot

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Page 34: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

32

Item Description Controller EtherNet/IPTM Controller EtherNet/IPTM

Version SD Card Slot ECOItem No. 750-893 750-823Order Text Controller EtherNet/IP; SD Controller EtherNet/IP; ECO

Technical DataCommunication EtherNet/IPTM adapter (slave) EtherNet/IPTM adapter (slave)ETHERNET protocols HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMP HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x RJ-45 2 x RJ-45Baud rate 10/100 Mbit/s 10/100 Mbit/sProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3) WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)Type of memory card SD and SDHC to 32 GB*Program memory/data memory/non-volatile memory (software)

8192 KB / 8192 KB / 32 KB 2048 KB / 2048 KB / 16 KB

Number of modules per node (max.) 250 250Input/output (internal) process image (max.) 1020 words / 1020 words 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interface (CAGE

CLAMP® connection)24 VDC (−25 … +30 %); via wiring interface

Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 500 mA 300 mACurrent consumption – system supply (5 V) 440 mA 390 mATotal current (system supply) 1700 mA 700 mASurrounding air temperature (operation) 0 … +55 °C 0 … +55 °CDimensions W x H x D 61.5 x 71.9 x 100 mm 49.5 x 71.9 x 96.8 mm

Approvals 1; ; Marine; r OrdLoc/HazLoc; 4 ATEX/IECEx

1; ; Marine; r OrdLoc/HazLoc; 4 ATEX/IECEx

Data sheet and further information, see: wago.com/750-893 wago.com/750-823

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

*All guaranteed specifications are only valid with the WAGO Memory Card listed as an accessory.

Controller EtherNet/IPTM

Figure: 750-893

1

8

ON

0: WBM255: DHCP I/O

NS

MS

LINKACT 1LINKACT 2

EtherNet/IP

USRSD

12

34

56

78

ON 24V 0V

+ +

— —

750-

893

X1

X2

A

B

01 02

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

24VX3

1

8

ON

0: WBM255: DHCP

0V

I/O

NS

MS

LINKACT 1LINKACT 2

EtherNet/IP

USR

12

34

56

78

ON

750-

823

X1

X2

Address

Fieldbus connection2 x RJ-45 (switched)

Supply voltage (system)

Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

Page 35: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

33

Item Description Controller BAcnet/IP; 4th generation; 2 x ETHERNET; SD card slot

Controller BACnet/IP; 4th generation; 2 x ETHERNET; SD card slot

Version ECOItem No. 750-832 750-832/000-002Order Text Controller BACnet/IP; G4; 2xETH; SD Controller BACnet/IP; G4; 2xETH; SD; Eco

750-832/000-002 Controllers support a maxi-mum of 256 BACnet objects.

Technical DataCommunication BACnet/IP; Modbus (TCP, UDP) BACnet/IP; Modbus (TCP, UDP)ETHERNET protocols HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMP HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x RJ-45 2 x RJ-45Baud rate 10/100 Mbit/s 10/100 Mbit/sProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3) WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)Type of memory card SD and SDHC to 32 GB* SD and SDHC to 32 GB*BACnet device profile B-BC (BACnet Building Controller) B-BC (BACnet Building Controller)BACnet revision 12 12Program memory/data memory/non-volatile memory (software)

8192 KB / 8192 KB / 28 KB 8192 KB / 8192 KB / 28 KB

Number of modules per node (max.) 250 250Input/output (internal) process image (max.) 1020 words / 1020 words 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interface (CAGE

CLAMP® connection)24 VDC (−25 … +30 %); via wiring interface (CAGE

CLAMP® connection)Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contacts 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 500 mA 500 mACurrent consumption – system supply (5 V) 440 mA 440 mATotal current (system supply) 1700 mA 1700 mASurrounding air temperature (operation) 0 … +55 °C 0 … +55 °CDimensions W x H x D 61.5 x 71.9 x 100 mm 61.5 x 71.9 x 100 mm

Approvals 1 1BACnet approvals WSPCert certification; BTL listing WSPCert certification; BTL listingData sheet and further information, see: wago.com/750-832 wago.com/750-832/000-002

Accessories Item No. Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108 758-879/000-2108BACnet Configurator Download: www.wago.com Download: www.wago.com

*All guaranteed specifications are only valid with the WAGO Memory Card listed as an accessory.

*All guaranteed specifications are only valid with the WAGO Memory Card listed as an accessory.

Controller BACnet/IP; 4th generation; 2 x ETHERNET; SD card slot

Figure: 750-832

X1

1

8

ON

0: WBM255: DHCP

X2

I/O

NS

LINKACT 1LINKACT 2

USRSD

12

34

56

78

ON 24V 0V

+ +

— —

750-

832

MS/BT

BACnet/IP A

B

01 02

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

X1

1

8

ON

0: WBM255: DHCP

X2

I/O

NS

LINKACT 1LINKACT 2

USRSD

12

34

56

78

ON 24V 0V

+ +

— —

MS/BT

BACnet/IP

750-

832/

000-

002

A

B

01 02

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

Page 36: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

34 Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

X1

1

8

ON

0: WBM255: DHCP

X2

I/O

NS

MS

LINKACT 1LINKACT 2

Modbus TCP

USRSD

12

34

56

78

ON 24V 0V

+ +

— —

01 02

750-

890

A

B

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Controller Modbus TCP

Item Description Controller Modbus TCP; 4. Generation; SD Card SlotVersion Standard Ext. temperature Telecontrol technol-

ogy; ext. temperature

Telecontrol technol-ogy; ext. temperature; Eco

Item No. 750-890 750-890/025-000 750-890/025-001 750-890/025-002Order Text Controller Modbus TCP;

G4; SDController Modbus TCP; G4; SD; T

Controller Modbus TCP; G4; SD; Tele; T

Controller Modbus TCP; G4; SD; Tele; T; Eco

Technical DataCommunication Modbus (TCP, UDP) Modbus (TCP, UDP); Telecontrol protocolsETHERNET protocols HTTP(S); BootP; DHCP; DNS; SNTP; (S)FTP; SNMPTelecontrol protocols IEC 60870-5-101/-103/-104; IEC 61850-7-4;

IEC 61400-25; DNP3Connection technology: fieldbus input/output 2 x RJ-45Baud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)Memory card type SD and SDHC up to 32 GB; All guaranteed specifications are only valid with the WAGO Memory Card

listed as an accessory.Program memory/data memory/non-volatile memory (software)

8192 KB / 8192 KB / 32 KB

Number of modules per node (max.) 250 4Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interface (CAGE CLAMP® connection) Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 500 mAPower consumption – system supply (5 V) 440 mATotal current (system supply) 1700 mASurrounding air temperature (operation) 0 … +55 °C −20 … +60 °CDimensions W x H x D 61.5 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLoc; 4 ATEX/IECExData sheet and additional information, see: wago.com/750-890

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

Page 37: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

35Supplementary Catalog – Automation Technology

Volume 3, Section 4 | Controllers

X1

1

8

ON

0: WBM255: DHCP

X2

I/O

NS

MS

LINKACT 1LINKACT 2

750-

890/

040-

000

USRSD

12

34

56

78

ON

ABCD

24V 0V

+ +

— —

01 02

Modbus TCP

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Controller Modbus TCP; Extreme

Item Description Controller Modbus TCP; 4. Generation; SD Card SlotVersion Extreme Telecontrol technology; extremeItem No. 750-890/040-000 750-890/040-001

Order Text Controller Modbus TCP; G4; SD; XTR Controller Modbus TCP; G4; SD; Tele; XTR

Technical DataCommunication Modbus (TCP, UDP) Modbus (TCP, UDP); Telecontrol protocolsETHERNET protocols HTTP(S); BootP; DHCP; DNS; SNTP; (S)FTP; SNMPTelecontrol protocols IEC 60870-5-101/-103/-104;

IEC 61850-7; IEC 61400-25; DNP3Connection technology: fieldbus input/output 2 x RJ-45Baud rate 10/100 Mbit/sVisualization Web-VisuProgramming WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)Memory card type SD and SDHC up to 32 GB; All guaranteed specifications are only valid with the WAGO Memory Card

listed as an accessory.Program memory/data memory/non-volatile memory (software)

8192 KB / 8192 KB / 32 KB

Number of modules per node (max.) 64Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via

power jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 500 mAPower consumption – system supply (5 V) 440 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 61.5 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLoc; 4 ATEX/IECExData sheet and additional information, see: wago.com/750-890/040-000 wago.com/750-890/040-001

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108

Page 38: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

36

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

WAGO I/O System AdvancedGeneral Product Information

Your Benefits:

• An open, innovative and future-proof automation system for mechanical engineering• The WAGO I/O System Advanced combines the proven benefits and functionality of

the 750 Series with an ergonomic design, error-preventing mechanics, and outstand-ing performance.

• The new WAGO Controller PFC200 ADV 2ETH combines the vast possibilities of PFC technology with the I/O System Advanced.

Top Performance for Industrial Auto-mation

Short reaction times, high signal trans-mission synchronicity and the ability to use fast ETHERNET fieldbuses like PROFINET, EtherCAT® and EtherNet/IPTM make the I/O System Advanced the new benchmark for high-end industrial automation systems.

The inherent strengths of the I/O System Advanced mean that more performance is with the integration of communica-tion protocols via TSN (Time-Sensitive Networking).

WAGO I/O System AdvancedUnites the Proven with Peak Performance

The WAGO I/O System Advanced capital-izes on the continuous development of the proven WAGO I/O System 750, uniting its industry-proven strengths with outstanding performance in a fresh and user-friendly design.The Controller PFC200 Advanced for the new I/O System is based on technology that is both time-tested and future-proof. These controllers connect the industry-proven PFC functionalities of the WAGO 750 Series I/O System with the I/O System Advanced. The new controller is a bridge to various IT and OT technologies. Sending data to the cloud and leveraging all the benefits of cloud com-puting are simple thanks to a large number of interfaces and the highest cybersecurity standards.

At the same time, operators profit from the system’s added value. Thus, programming with intuitive e!COCKPIT Engineering Soft-ware comes into play for automation tasks. To fulfill special requirements, the possibil-ities of the open Linux® operating systems and Docker process visualization can be used.The gateway offers a direct start with the broad product range of the 750 Series I/O System. Thanks to a wide variety of I/O mod-ules available, the system’s ready for use in virtually any application today.

Made for TSN

Connectivity and speed are the founda-tions of modern production facilities. With the WAGO I/O System Advanced, WAGO has developed a new IP20 solution that integrates cutting-edge technologies such as TSN and OPC UA. This means the new I/O system readily meets all the require-ments placed on a future-proof automation system.  

Page 39: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

37

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

A

C

E

a)

b)

c)

B

G

F

d)

f)

e)a)

b)

c)

d)

b)

c)

d)

b) d)

D

H

a) a)

a) e)

WAGO I/O System AdvancedInterfaces and Types

• Including supply module to power downstream I/O modules (a)

• Connection technology (system/field supply): Push-in CAGE CLAMP®; Conductor cross-section (mechanical): solid/fine-stranded: 0.25 … 2.5 mm² / 22 … 14 AWG

• Address switch (b)• Fieldbus interface 2 x RJ-45 (c)• Service interface (d)• W x H x D (mm) 63 x 105 x 75

Housing Design: Controller PFC200 (A)

• Start/stop switch (e)• microSD card slot for external storage media (f)

Housing Design: Fieldbus Coupler (B)

• Supply modules consist of an electronic unit with integrated base unit (a) and pluggable wiring unit (c).

• Conductor cross-section (mechanical): solid/fine-stranded: 0.25 … 2.5 mm² / 22 … 14 AWG

• W x H x D (mm) 12 x 105 x 75

Housing Design: Power Supply with Fuse Holder (E)

• Fuse holder (e) for (5 x 20) mm fuse

• 4 connection points (Push-in CAGE CLAMP®) for field supply

Housing Design: System Power Supply (F)

• 6 connection points (Push-in CAGE CLAMP®) for system/field supply

Housing Design: End Modul (G)

• The end module completes the internal data bus and protects the contacts.

• W x H x D (mm) 8.5 x 105 x 75

Housing Design: 750 Series Gateway (H)

• The 750 Series Gateway connects the 750/753 Series Modules to an I/O node of the WAGO I/O System Advanced.

• W x H x D (mm) 12 x 105 x 65

Housing Design: I/O Module (C, D)

• Function differentiation by color coding (a) yellow = digital input; red = digital output; gray = supply

• I/O modules consist of an electronic unit (b), a base unit (c) and a pluggable wiring unit (d).

• 16 connection points (Push-in CAGE CLAMP®) Conductor cross-section (mechanical): solid/fine-stranded: 0.25 … 1.5 mm² / 22 … 16 AWG

• W x H x D (mm) 12 x 105 x 75

Page 40: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

38

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

+

+

DSH11

ECH12

RUNAPP

RST

X3

768-

3301

PFC2

00 AD

V 2ET

H

SF

1

2

3

4

5

6

PS

ACT

ACT

LNK

LNK

X1X2

RUNSTOPRESET

12

34

56

78

ON

DIP

0=DH

CP/SW

255=

BootP

µSD

Power jumper contacts

0 V Field

0 V Field

+ Field

+ Field

0 V System

+24 V System

System bus contacts

Device statusError codeModule statusNetwork statusIEC RUNapplication

Fieldbus connectionRJ-45

Fieldbus connectionRJ-45

Service interface USB-C

System supplyField supply

Power status

Controller PFC200; I/O System Advanced; 2 x ETHERNET

Item Description Controller PFC200; I/O System Advanced; 2 x ETHERNETItem No. 768-3301Order Text PFC200 ADV 2ETH

Technical DataCommunication Modbus (TCP, UDP)ETHERNET protocols DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSHVisualization Web-VisuProgramming e!COCKPIT (based on CODESYS V3)CPU Cortex A8; 1 GHzOperating system Real-time Linux (with RT-Preempt patch)Main memory (RAM)/internal memory (flash)/non-volatile memory (hardware)

512 MB / 4 GB / 64 KB

Program memory/data memory/non-volatile memory (software)

60 MB / 60 MB / 64 KB; for memory configuration via e!RUNTIME, the program and data memory together have a maximum size of 60 MB and can be distributed dynamically.

Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsInput/output (Modbus®) process image (max.) 1000 words / 1000 wordsSupply voltage (system) SELV 24 VDC (-25 … +30 %)Power consumption – system supply (power supply) at max. local bus supply

850 mA

Power consumption – system supply (power supply) without local bus supply

180 mA

Total current for system supply (local bus) (max.)

3000 mA

Supply voltage (field) SELV 24 VDC (-25 … +30 %)Current carrying capacity (power jumpercontacts)

12 A (requires external fusing of the field supply)

Isolation – field/system min. 1000 VDC (1 min); per EN/UL 61010-2-201Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installationDimensions W x H x D 63 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/768-3301

Accessories Item No.microSD Memory Card; SLC-NAND; 2 GB 758-879/000-3102microSD Memory Card; pSLC-NAND; 8 GB 758-879/000-3108

Page 41: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

39

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

+

+

DS

0: OFFID 1-255

x 16

x 1

RNECER

RST

X3

768-

2201

FC AD

V Ethe

rCAT

0F

EDCBA98 7 6 543210F

EDCBA98 7 6 54321

SF

1

2

3

4

5

6

PS

100

100

L/AL/A

IN

OUT

X1X2

Device statusError codeEtherCAT RUNEtherCAT ERROR

Fieldbus connectionRJ-45

Fieldbus connectionRJ-45

0 V Field

0 V Field

+ Field

+ Field

0 V System

+24 V System

System bus contacts

Service interface USB-C

System supplyField supply

Power status

Power jumper contacts

Fieldbus Coupler; I/O System Advanced; EtherCAT®

Item Description Fieldbus Coupler; I/O System Advanced; EtherCAT®Item No. 768-2201Order Text FC ADV ETHERCAT

Technical DataFieldbus EtherCAT®Protocols EtherCAT® (direct mode)Connection technology: fieldbus input/output 2 x RJ-45Baud rate 100 Mbit/sTransmission medium Shielded Twisted Pair S/FTP, F/FTP or SF/FTP; 100 Ω; Cat. 6Transmission performance Class D per EN 50173-1Number of modules per node (max.) 250Input/output (internal) process image (max.) 1000 words / 1000 wordsSupply voltage (system) SELV 24 VDC (-25 … +30 %)Power consumption – system supply (power supply) at max. local bus supply

900 mA

Power consumption – system supply (power supply) without local bus supply

160 mA

Total current for system supply (local bus) (max.)

3000 mA

Supply voltage (field) SELV 24 VDC (-25 … +30 %)Current carrying capacity (power jumper contacts)

12 A (requires external fusing of the field supply)

Isolation – field/system min. 1000 VDC (1 min); per EN/UL 61010-2-201Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installationDimensions W x H x D 63 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/768-2201

EtherCAT® is a registered trademark and patented technology of Beckhoff Automation GmbH.

Page 42: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

40

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

10 µs

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

DI 1+24 VDCDI 2+24 VDCDI 3+24 VDCDI 4+24 VDCDI 5+24 VDCDI 6+24 VDCDI 7+24 VDC

DI 8+24 VDC

+ Field

0 V Field

3 ms

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

+ Field

0 V

DI 1DI 2DI 3DI 4DI 5DI 6DI 7DI 8DI 9DI 10DI 11DI 12DI 13DI 14

DI 15DI 16

U+U+U+U+U+U+U+U+U+U+U+U+U+U+

U+U+

Digital Input; I/O System Advanced; 24 VDC

Figure: 763-1108

Item Description 8-Channel Digital Input; I/O System Advanced; 24 VDC

16-Channel Digital Input; I/O System Advanced; 24 VDC

Version FastItem No. 763-1108 763-1116Order Text 8DI ADV 24V DC HS 16DI ADV 24V DC

Technical DataNumber of digital inputs 8 16Signal type 24 VDC 24 VDCInput characteristic Type 3, per IEC 61131-2 Type 3, per IEC 61131-2Sensor connection 8 x (2-wire) 16 x (1-wire)Total current – sensor supply (max.) 600 mAInputs

Input characteristic High-side switching High-side switchingInput filter 1 μs 3 msPulse width (min.) 10 μsDelay time T_on from 0 to 1 < 3 μs 3 msDelay time T_off from 1 to 0 < 6 μs 3 msInput current 2.4 mA at 24 V 2.4 mA at 24 V

Dielectric strength up to ±35 V, at the digital input up to ±35 V, at the digital inputGround reference of the inputs Common ground (0 V) Common ground (0 V)Supply voltage (field) SELV 24 VDC (-25 … +30 %) SELV 24 VDC (-25 … +30 %)Current consumption, field supply (module with no external load)

14 mA 5 mA

Power consumption, system supply (local bus) 47 mA 47 mAData width 8-bit channel status 16-bit channel statusCurrent carrying capacity (power jumpercontacts)

12 A 12 A

Isolation – field/system min. 1000 VDC (1 min); per EN/UL 61010-2-201

min. 1000 VDC (1 min); per EN/UL 61010-2-201

Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installation

−25 … +60 °C; horizontal, typical control cabinet installation

Dimensions W x H x D 12 x 105 x 75 mm 12 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2 per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4 per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLoc 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-1108 wago.com/763-1116

Page 43: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

41

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

0.5 A

+ Field

0 V

DO 10 VDO 20 VDO 30 VDO 40 VDO 50 VDO 60 VDO 70 V

DO 80 V

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

0.5 A

+ Field

0 V

U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒U‒

DO 1DO 2DO 3DO 4DO 5DO 6DO 7DO 8DO 9DO 10DO 11DO 12DO 13DO 14

DO 15DO 16

Digital Output; I/O System Advanced; 24 VDC 0.5 A

Item Description 8-Channel Digital Output; I/O System Advanced; 24 VDC 0.5 A

16-Channel Digital Output; I/O System Ad-vanced; 24 VDC 0.5 A

Version FastItem No. 763-1508 763-1516Order Text 8DO ADV 24V DC 0.5A HS 16DO ADV 24V DC 0.5A

Technical DataNumber of digital outputs 8 16Signal type 24 VDC 24 VDCActuator connection 8 x (2-wire) 16 x (1-wire)Outputs

Output characteristic Semiconductor, push-pull Semiconductor, high-side switchingOutput current per channel 0.5 A; short-circuit-protected; self-resetting 0.5 A; short-circuit-protected; self-resettingOutput current (module) (max.) 4 A 8 AOutput voltage 24 VDC 24 VDCDelay time T_on from 0 to 1 < 2 μsDelay time T_off from 1 to 0 < 2 μsLoad type Resistive: 48 Ω … 16 kΩ, at 24 V;

Inductive: DC13;Lamp load: up to 5 W

Resistive: 48 Ω … 16 kΩ, at 24 V;Inductive: DC13;

Lamp load: up to 5 WSwitching frequency (max.) with load type 15 kHz, resistive load;

3 Hz, inductive load;500 Hz, lamp load

1 kHz, resistive load;3 Hz, inductive load;

500 Hz, lamp loadSupply voltage (field) SELV 24 VDC (-25 … +30 %) SELV 24 VDC (-25 … +30 %)Current consumption, field supply (module with no external load)

24 mA 26 mA

Power consumption, system supply (local bus) 70 mA 75 mAData width 8-bit channel status 16-bit channel statusGround reference of the outputs Common ground (0 V) Common ground (0 V)Current carrying capacity (power jumpercontacts)

12 A 12 A

Isolation – field/system min. 1000 VDC (1 min);per EN/UL 61010-2-201

min. 1000 VDC (1 min);per EN/UL 61010-2-201

Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installation

−25 … +60 °C; horizontal, typical control cabinet installation

Dimensions W x H x D 12 x 105 x 75 mm 12 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2 per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4 per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLoc 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-1508 wago.com/763-1516

Figure: 763-1508

Page 44: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

42

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

1

2

3

4+ 24 V

0 V

+ Field

+ Field

0 V Field

0 V Field

Supply Module; I/O System Advanced; 24 VDC; Fuse Holder

Item Description Supply Module; I/O System Advanced; 24 VDC; Fuse Holder

Item No. 763-5101Order Text PS ADV 24V DC FUSE

Technical DataSupply voltage (field) SELV 24 VDC (-25 … +30 %)Total current for field supply (24 V) 6.3 ADC (max.)Replaceable fuse 5 x 20; T 6.3 A (not included);

PV (max.) = 1.6 W; Observe the fuse derating!Data width 2 bits;

Bit 0: Power supply status (field) in front of the fuse;Bit 1: Power supply status (field) behind the fuse (at

the power jumper contacts)Power consumption, system supply (local bus) 43 mACurrent consumption, field supply (module with no external load)

6 mA

Current carrying capacity (power jumpercontacts)

12 A

Isolation – field/system min. 1000 VDC (1 min);per EN/UL 61010-2-201

Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installation

Dimensions W x H x D 12 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-5101

This I/O module provides the applied supply voltage, protected by fuse, to the field devices connected to downstream I/O modules. A blown fuse failure and the field power supply status are indicated by a LED.

Page 45: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

43

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

3

4

5

6

1

2

24 V

5 V

+ 24 V

0 V

+ Field

+ Field

+24 V System

0 V System

0 V Field

0 V Field

System Power Supply; I/O System Advanced; 24 VDC

Item Description System Power Supply; I/O System Advanced; 24 VDC

Item No. 763-5120Order Text PS SYSTEM ADV 24V DC

Technical DataSupply voltage, system (24 V) SELV 24 VDC (-25 … +30 %)Power consumption, system supply (power supply) at max. local bus supply

900 mA

Power supply efficiency (typ.) at nominal load (24 V)

95 %

Total current for system supply (local bus) (max.)

3900 mA

Supply voltage (field) SELV 24 VDC (-25 … +30 %)Current consumption, field supply (module with no external load)

3 mA

Data width 1 bit;Bit 0: Power supply status (field)

Current carrying capacity (power jumper contacts)

12 A (external fusing of the field supplyrequired)

Isolation – field/system min. 1000 VDC (1 min);per EN/UL 61010-2-201

Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installation

Dimensions W x H x D 12 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-5120

This I/O module provides the applied supply voltage to the field devices connected to down-stream I/O modules. It also serves as an additional system supply for large nodes, covering the power demands of the I/O modules themselves.

Page 46: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

44

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

+ Field

0 V Field

WAG

O I/

O S

yste

m A

dvan

ced

WAG

O I/

O S

yste

m 7

50

750 Series Gateway; I/O System Advanced

Item Description 750 Series Gateway; I/O System AdvancedItem No. 763-4750/010-000Order Text GW 750 ADV

Technical DataSupply voltage (field) SELV 24 VDC (-25 … +30 %)Number of modules (max.) 32Power consumption, system supply (local bus) 80 mATotal current for system supply (5 V) 700 mACurrent carrying capacity (power jumper contacts)

10 A (external fusing of the field supplyrequired)

Isolation – field/system min. 500 VDC (1 min);per EN/UL 61010-2-201

Surrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installation

Dimensions W x H x D 12 x 105 x 65 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-4750/010-000

Page 47: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

45

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

End Module; I/O System Advanced

Item Description End Module; I/O System AdvancedItem No. 763-5600Order Text End Module

Technical DataSurrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet

installationDimensions W x H x D 8.5 x 105 x 75 mmEMC immunity to interference per EN 61000-6-1, -2EMC emission of interference per EN 61000-6-3, -4

Approvals 1; r OrdLoc/HazLocData sheet and additional information, see: wago.com/763-5600

An end module must be snapped onto the assem-bly at the end of a fieldbus node.The end module completes the internal data bus and protects the contacts.Two fuses (e.g., for the 763-5101 Field Supply Module) can be plugged into the end module as a reserve.

Page 48: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

46

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

Item Description Base Module; I/O System AdvancedItem No. 763-301Order Text BASE MODULE ADV 24 V

Technical DataColor Light grayPower consumption – system supply (5 V) 2 mANumber of incoming power jumper contacts 2Number of outgoing power jumper contacts 2Supply voltage (field) SELV 24 VDC (-25 … +30 %)Total current for system supply (local bus) (max.)

12 A

Isolation – field/system min. 1000 VDC (1 min); per EN/UL 61010-2-201Dimensions W x H x D 12 x 105 x 75 mmWeight 69 gSurrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installationSurrounding air temperature (storage) −40 … +85 °CRelative humidity (without condensation) 95 %Pollution degree 2Operating altitude Without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 3000 m (0.5 K/100 m)

Item Description Wiring Unit; I/O System AdvancedVersion 16-pole 6-pole 4-poleItem No. 763-351 763-353 763-354Order Text CONNECTOR ADV 16p CONNECTOR ADV 6p CONNECTOR ADV 4p

Technical DataColor Light grayNumber of connections 16 6 4Rated voltage 50 V 300 VNominal current 6 A 16 AConnection technology Push-in CAGE CLAMP®Conductor cross-section (mechanical) Solid/fine-stranded:

0.25 … 1.5 mm² / 22 … 16 AWG; With insulated ferrule: 0.75 mm²

(max.)

Solid/fine-stranded: 0.25 … 2.5 mm² / 22 … 14 AWG;

With insulated ferrule: 0.75 mm² (max.)

Strip length 8 … 9 mm / 0.33 inchDimensions W x H 12 x 75 mm 12 x 60 mmWeight 16 g 12 g 9 gSurrounding air temperature (operation) −25 … +60 °C; horizontal, typical control cabinet installationSurrounding air temperature (storage) −40 … +85 °CRelative humidity (without condensation) 95 %Pollution degree 2Operating altitude Without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 3000 m (0.5 K/100 m)

Accessories I/O System Advanced

A module consists of a base module, an electronic module and a pluggable connector. Optionally, the wiring unit and the base unit can be ordered separately.

Wiring unit

Electronic unit

Base Unit

Page 49: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

47

Volume 3 | I/O System Advanced

Supplementary Catalog – Automation Technology

Screwless end stop; 14 mm wide; for 35 x 15 and 35 x 7.5 DIN-railsColor Item No. Pack. Unitgray 249-198 10

TS35 14

16,54060

59,5

Micro-WSB-Inline; 2000 pieces on roll; plain; snap-on typeColor Item No. Pack. Unitwhite 2009-141 1

Accessories I/O System Advanced

Page 50: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

48

Fieldbus Coupler EtherNet/IPTM

Item Description Fieldbus Coupler EtherNet/IPTM

Version StandardItem No. 750-363Order Text FC EtherNet/IP

Technical DataFieldbus EtherNet/IPTM adapter (slave)Protocols HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x RJ-45Bus segment length (max.) 100 mBaud rate 10/100 Mbit/sTransmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; Line length

(max.): 100 mNumber of modules per node (max.) 250Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interfaceInput current (typ.) at nominal load (24 V) 280 mACurrent consumption – system supply (5 V) 350 mATotal current (system supply) 700 mASurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 49.5 x 71.9 x 96.8 mm

Approvals 1; ; Marine; r OrdLoc/HazLoc; 4 ATEX/IECEx

Data sheet and further information, see: wago.com/750-363

24VX3

1

8

ON

0: WBM255: DHCP

0V

I/O

NS

MS

LINKACT 1LINKACT 2

12

34

56

78

ON

750-

363

X1

X2

EtherNet/IP

Address

Fieldbus connection2 x RJ-45 (switched)

Supply voltage (system)

Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Page 51: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

49

Fieldbus Coupler BACnet/IP

Item Description Fieldbus Coupler BACnet/IPItem No. 750-332Order Text FC BACnet/IP

Technical DataFieldbus BACnet/IP; Modbus (TCP, UDP)Protocols HTTP(S), BootP, DHCP, DNS, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x RJ-45Transmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; Line length

(max.): 100 mBaud rate 10/100 Mbit/sTransmission performance Class D per EN 50173Type of memory card SD and SDHC to 32 GB*BACnet device profile B-BC (BACnet Building Controller)BACnet revision 12Number of modules per node (max.) 250Supply voltage (system) 24 VDC (−25 … +30 %); via wiring interface (CAGE

CLAMP® connection)Supply voltage (field) 24 VDC (−25 … +30 %); via power jumper contactsInput current (typ.) at nominal load (24 V) 500 mACurrent consumption – system supply (5 V) 440 mATotal current (system supply) 1700 mASurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 61.5 x 71.9 x 100 mm

Approvals 1BACnet approvals WSPCert certification: Pending;BTL listingData sheet and further information, see: wago.com/750-332

Accessories Item No.SD Memory Card; SLC-NAND; 2 GB 758-879/000-001

SD Memory Card; pSLC-NAND; 8 GB 758-879/000-2108BACnet Configurator Download: www.wago.com

*All guaranteed specifications are only valid with the WAGO Memory Card listed as an accessory.

X1

1

8

ON

0: WBM255: DHCP

X2

I/O

NS

MS/BT

LINKACT 1LINKACT 2

BACnet/IP

SD

12

34

56

78

ON 24V 0V

+ +

— —

750-

332

A

B

01 02

Address

SD memory card slotFieldbus connection2 x RJ-45

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Page 52: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

50 Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

1

2

3

4

5

6

7

8

13

12

11

10

9

14

15

16

24 V

0 V

‒TC 1

‒TC 6+TC 6

+TC 1

‒TC 2

‒TC 3

‒TC 4

‒TC 5

+TC 2

+TC 3

+TC 4

+TC 5

‒TC 7

‒TC 8

+TC 7

+TC 8

Analog Input; Thermocouple; Adjustable

Item Description 8-Channel Analog Input; Thermocouple; Adjustable

Version Standard with 16 connectorsItem No. 750-498Order Text 8AI; TC; Adjust

Technical DataNumber of analog inputs 8Signal type Temperature and voltagesSignal characteristic Single-endedSensor types Type K, J, B, E, N, R, S, T, C;

Voltage measurement: ±30 mV; ±60 mV;±120 mV; ±240 mV

Sensor connection 2-wireInput resistance ≥ 10MΩResolution 0.1 °C for temperature measurements;

0.01 mV at ±240 mV; 0.005 mV at ±120 mV; 0.0025 mV at ±60 mV;0.00125 mV at ±30 mV

Conversion time ≤ 100 ms (per channel), activated notch filter;≤ 50 ms (per channel), deactivated notch filter

Measurement error at 25 °C and in nominal mounting position

with internal cold junction compensation≤ ±1 K (type E, N, K, T, J) at ≥ -50 °C;

≤ ±2 K (type S, R, C) at ≥ 100 °C;≤ ±3 K (type B) at ≥ 350 °C;

(More information on measurement erroris available in the manual)

Temperature error (max.) Type K: ±0.05 K/K of the upper-range value;Voltage measurements: ±50 ppm/K of the up-

per-range valueCold junction compensation Module-internal based on a cold junction tem-

perature measurementSupply voltage (field) 24 VDC (−25 … +30 %); via power jumper contacts

(power supply via blade contact; transmission via spring contact)

Power consumption – system supply (5 V) 100 mAData width 8 x 16-bit data; 8 x 8-bit control/status (optional)Isolation 500 V system/fieldSurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 12 x 69 x 100 mm

Approvals 1; r OrdLocData sheet and additional information, see: wago.com/750-498

Page 53: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

51Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Analog Output; Voltage/Current

Item Description 4-Channel Analog Output; Voltage/CurrentVersion Standard with 16 connectorsItem No. 750-564Order Text 4 AO U/I

Technical DataNumber of analog outputs 4Signal type 0 … 5 V; 1 … 5 V; ±5 V; 0 … 10 V; 2 … 10 V; ±10 V;

0 … 10 mA; 2 … 10 mA; ±10 mA; 0 … 20 mA; 4 … 20 mA; ±20 mA;

0 … 12 V; ±12 V; 0 … 22 mA; ±22 mA; 0 … 12 mA; ±12 mA

Actuator connection I: 2-wire; U: 2-wire; 4-wireLoad impedance ≥1 kΩ (voltage); ≤600 Ω (current)Resolution 16 bitsConversion time ≤3 msOutput error (max.) at 25 °C U/I: ±0.05 % of the upper-range value

0 … 12 V / ±12 V: ±0.075 % of the upper-range value

Temperature error (max.) U: ±25 ppm/K of the upper-range value;I: ±50 ppm/K of the upper-range value

Supply voltage (field) 24 VDC (−15 … +30 %); via power jumper contacts (power supply via blade contact; transmission via

spring contact)Power consumption – system supply (5 V) 55 mAData width 4 x 16-bit data; 4 x 8-bit control/status (optional)Isolation 500 V system/fieldSurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 12 x 69 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLoc; 4 ATEX/IECEx

Data sheet and additional information, see: wago.com/750-564

1

2

3

4

5

6

7

8

13

12

11

10

9

14

15

16

U/I

+S3

+AO1

+S1

+AO2

+S2

+AO3

+AO4

+S4

-AO1-S1

-AO2-S2

-AO3-S3

-AO4-S4

-AO1

-S3

-S1

-AO2

-S2

-AO3

-AO4

-S4

24 V

0 V

Page 54: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

52 Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

DALI Multi-Master

Item Description DALI Multi-Master This manufacturer-independent DALI standard ensures interoperability of DALI devices in light-ing applications. This standard is substitute for the 1–10 V dimmer interface.

In addition to 64 DALI actuators (ECGs), a DALI Multi-Master Module supports up to 16 multi-sensors (max. 64 sensor addresses). Each DALI ECG can be assigned to 16 groups and 16 scenes. The DALI Multi-Master Module also of-fers 16 additional virtual groups on the DALI bus.

DALI control devices can be seamlessly integrat-ed with all other building systems. Several DALI masters can be connected to a single fieldbus node. The maximum number of modules that can be connected to a controller depends on the memory required by the application. Func-tion blocks prepared for DALI are available for programming fieldbus nodes.

Alternatively, an “EASY Mode” allows lighting functions to be readily controlled without any PLC programming.

The DALI Configurator simplifies commissioning of the DALI network. It provides the following functions: easy commissioning, configuration, service, support and maintenance of the DALI network.

Version Pluggable

Item No. 753-647

Order Text DALI Multi-Master

Technical DataPluggable connector ●Number of control gears/control devices(DALI)

Addressable: 64 control gears + 64 control devices

Baud rate 1200 bit/sBus length (max.) 300 mBus topology Star/line/combinationSupply voltage (DALI) 18 V (external)Number of control gear groups 16 (+ 16 virtual groups)Number of scenes 16Power consumption – system supply (5 V) 85 mAData width (internal) 24 bytesIsolation 2100 VDC DALI bus/local busSurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 12 x 69 x 100 mm

Approvals 1; ; Marine; r OrdLoc IEC 62386: DALI-2

Data sheet and additional information, see: wago.com/753-647

Accessories Item No.DALI Multi-Master DC/DC Converter (for supplying a single module)

753-620

Switched-Mode Power Supply; for DALI Multi-Master (753-647); 1-phase; Output volt-age: 18 VDC; Output current: 1.1 A

787-1007

Plug includedCoding keys included

-U -U

+U +U

-DALI -DALI

+DALI +DALI

Page 55: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

53Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Safe Analog Input; 4 Channels; 0/4 … 20 mA; Differential Input; PROFIsafe

Item Description Safe Analog Input; 4 Channels; 0/4 … 20 mA; Differential Input; PROFIsafe

Version Default Pluggable (delivery without connector)

Item No. 750-668/000-004 753-668/000-004Order Text 4FAI 0/4-20 mA Diff

PROFIsafe4FAI 0/4-20 mA Diff PROFIsafe

Technical DataPluggable connector ●Number of analog inputs 4Achievable safety classes SIL 3; Category 4, PLe (two-channel);

SIL 2; Category 2; PLd (one-channel)Protocol PROFIsafe V2Configuration options PROFIsafe address adjustable via DIP switch or

engineering softwareSensor connection 2-wire; 3-wire; 4-wireSignal characteristic DifferentialResolution 16 bitsLoad impedance < 300 ΩCommon mode voltage ±60 V (max.)Sampling frequency 100 Hz, 60 Hz, 50 Hz, 10 Hz; configurableMeasurement error (max.) at 25 °C ±0.05 % of the upper-range valueTemperature error (max.) 0.0065 %/K of the upper-range valueSensor supply Outputs L1 … L4Output current per channel/module (total) 1.5 A / 1.5 ASupply voltage (field) 24 VDC, SELV/PELV (−25 … +30 %); via power

jumper contacts (power supply via blade contact; transmission via spring contact)

Power consumption, field supply (modulewith no external load)

40 mA

Supply voltage (system) 5 VDC; via data contactsPower consumption – system supply (5 V) 120 mASurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 24 x 70.9 x 100 mm

Safety standards IEC 61508, parts 1-7: 2010; EN ISO 13849-1: 2015;

EN 62061Approvals 1; Marine; r OrdLoc/HazLoc; 4 ATEX/IECExData sheet and additional information, see: wago.com/

750-668/000-004wago.com/

753-668/000-004

Accessories Item No.Pluggable connector, safety 753-120

Coding keys 753-150

Figure: 750-668/000-004

Figure: 753-668/000-004

9

10

11

12

13

14

15

16

24 V

AI1+AI1-

AI2+AI2-

AI3+AI3-

AI4+AI4-

L4+L4-

L3+L3-

L2+L2-

L1+L1-

24 V

0 V µC

µC

AD

+‒

+‒

µC

µC

Logic

Systemsupply

AIx+

24�VDC

AIx−

LogicLx+

Sens

or

24�VDC

Lx− 0�V

Page 56: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

54 Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Digital Input; NAMUR; Ex i

Item Description 8-Channel Digital Input; NAMUR; Intrinsically safe

The process image can be used to define the sensor type (break or make contact) as well as to switch off the diagnostics (e.g., if contact monitoring in order to suppress the LED diagnostics).

Item No. 750-439Order Text 8DI; NAMUR; Ex i

Technical DataNumber of digital inputs 8Signal type NAMURSensor connection 2-wireInput characteristic High-side switchingInput filter (digital) 3 msOpen-circuit voltage 8.2 VDCDiagnostics Short circuit; wire break (can be switched off)Supply voltage (sensor) 8.2 VDC; short-circuit-protected;

isolated channelsSupply voltage (field) 24 VDC (Ex i power supply: Uo = max. 27.3 V); via

power jumper contacts (power supply via blade contact; transmission via spring contact)

Power consumption, field supply (module with no external load)

11 mA

Power consumption – system supply (5 V) 56 mAData width (internal) 16 bitsIsolation 300 VAC system/supplySurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 24 x 67.8 x 100 mm

Explosion protectionSafety-relevant data (circuit) Uo = 11.76 V; Io = 12.4 mA; Po = 36.67 mW;

Linear characteristic curveReactances Ex ia IIC Lo = 100 mH; Co = 1 μF Reactances without accounting for the concur-

rence of capacitance (Co) and inductance (Lo)Reactances Ex ia IIB Lo = 100 mH; Co = 9.9 μFReactance Ex ia IIA Lo = 100 mH; Co = 39 μFReactances Ex ia I Lo = 100 mH; Co = 30 μF

Ex standard EN IEC 60079-0, -7, -11Approvals 1; ; Marine; r OrdLoc/HazLoc/AEx;

4 ATEX/IECEx; INMETROIdentification 4 ATEX/IECEx: I (M1)

II 3 (1) GII (1) D

[Ex ia Ma] IEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC

Data sheet and additional information, see: wago.com/750-439

24 V

0 V

9

10

11

12

13

14

15

16

3 ms

--

A

--

A

--

A

--

A

--

A

--

A

--

A

--

A

DI 1DI 2

DI 5

0 V 0 V

0 V 0 V

DI 3DI 4

DI 7

DI 6

DI 8

Page 57: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

55Supplementary Catalog – Automation Technology

Volume 3, Section 5 | I/O System ‒ 750 and 753 Series

Analog Input; RTD/TC; Ex i

Item Description 4-Channel Analog Input; RTD/TC; Intrinsically safeItem No. 750-489Order Text 4AI; RTD/TC; Ex i

Technical DataNumber of analog inputs 4Signal type Resistance thermometers; Resistors; Potentiometer setting; Thermocouples; mV sensorsSensor connection RTD/R: 2 wires; 3 wires; 4 wires; TC/U: 2 wiresMeasurement ranges Resistance thermometers:

Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Ni1000-TK5000; Resistors: 250 Ω, 500 Ω, 1 kΩ, 2 kΩ, 4 kΩ, PTC; Potentiometer setting: 0 … 100 %;

Thermocouples: Type B, C, E, J, K, N, R, S, T; mV sensors: ±30 mV; ±60 mV; ±120 mV; ±250 mV; ±500 mV; ±1.000 mV; ±2.000 mV

Resolution 0.1 K of full scale value; 0.01 K of full scale value (restricted to -50 °C ...+150 °C)Conversion time ≥10 ms/2 wires (per channel); ≥20 ms/3 wires, 4 wires (per channel)Measurement error typ. (25 °C) ±0.2 % of the upper-range value; after user calibration: ±0.05 %Temperature error (typ.) ±0.001 %/K of the upper-range valueCold junction compensation IntegratedSupply voltage (field) 24 VDC (Ex i power supply: Uo = max. 27.3 V); via power jumper contacts (power supply via blade contact;

transmission via spring contact)Power consumption, field supply (module with no external load)

120 mA

Power consumption – system supply (5 V) 60 mAData width 4 x 16-bit data; 4 x 8-bit control/status (optional)Isolation acc. to EN/IEC 60079-11: 300 VAC system/supply;

acc. to EN/UL 61010-2-201: 1200 VDC system/supply/channelSurrounding air temperature (operation) 0 … +55 °CDimensions W x H x D 24 x 67.8 x 100 mm

Explosion protectionSafety-relevant data (circuit) Uo = 4 V; Io = 13.46 mA; Po = 13.46 mW; Linear characteristic curveReactances Ex ia IIC Lo = 0,19 H; Co = 100 μFReactances Ex ia IIB Lo = 0,78 H; Co = 1000 μFReactance Ex ia IIA Lo = 1,57 H; Co = 1000 μFReactances Ex ia I Lo = 2,57 H; Co = 1000 μFReactances Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Ex standard EN IEC 60079-0, -7, -11Approvals 1; ; Marine; r OrdLoc/HazLoc/AEx; 4 ATEX/IECExIdentification 4 ATEX/IECEx: II 3 (1) G

II (1) DI (M1)

Ex ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC[Ex ia Ma] I

Data sheet and additional information, see: wago.com/750-489

24 V

0 V

9

10

11

12

13

14

15

16

–E1

–I1

–I2

–E2

–E3

–I3

–I4

–E4

+E1

+I1

+I2

+E2

+E3

+I3

+I4

+E4

2 / 3 / 4 wiresTC

Page 58: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

56 Supplementary Catalog – Automation Technology

Volume 3, Section 6 | I/O System – 750 XTR Series

24VX3

X1

1

8

ON

0: WBM255: DHCP

X2

0V

I/O

NS

MS

LINKACT 1LINKACT 2

Modbus TCP

750-

362/

040-

000

12

34

56

78

ON

Address

Fieldbus connection2 x RJ-45

Supply voltage (system)

Fieldbus Coupler Modbus TCP; Extreme

Item Description Fieldbus Coupler Modbus TCP; 4th GenerationVersion ExtremeItem No. 750-362/040-000Order Text FC Modbus TCP; G4; XTR

Technical DataFieldbus Modbus (TCP, UDP)Protocols HTTP(S), BootP, DHCP, DNS, (S)FTP, SNMPConnection technology: fieldbus input/output RJ-45Bus segment length (max.) 100 mBaud rate 10/100 Mbit/sTransmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5Number of modules per node (max.) 64Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interfaceInput current (typ.) at nominal load (24 V) 280 mAPower consumption – system supply (5 V) 350 mATotal current (system supply) 700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 49.5 x 71.9 x 96.8 mm

Approvals 1; Marine*; r OrdLoc*/HazLoc*; 4 ATEX*/IECEx*

Data sheet and additional information, see: wago.com/750-362/040-000

*pending

Page 59: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

57Supplementary Catalog – Automation Technology

Volume 3, Section 6 | I/O System – 750 XTR Series

24VX3

X1

1

8

ON

0: WBM255: DHCP

X2

0V

I/O

NS

MS

LINKACT 1LINKACT 2

12

34

56

78

ON

750-

363/

040-

000

EtherNet/IPTM

Address

Fieldbus connection2 x RJ-45

Supply voltage (system)

Fieldbus Coupler EtherNet/IPTM; Extreme

Item Description Fieldbus Coupler EtherNet/IPTM; 4th GenerationVersion ExtremeItem No. 750-363/040-000Order Text FC EtherNet/IP; G4; XTR

Technical DataFieldbus EtherNet/IPTM adapter (slave)Protocols HTTP(S), BootP, DHCP, DNS, SNTP, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x RJ-45Bus segment length (max.) 100 mBaud rate 10/100 Mbit/sTransmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; Line length

(max.): 100 mNumber of modules per node (max.) 64Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC (−25 … +30 %); via wiring interfaceInput current (typ.) at nominal load (24 V) 280 mAPower consumption – system supply (5 V) 350 mATotal current (system supply) 700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 49.5 x 71.9 x 96.8 mm

Approvals 1; Marine*; r OrdLoc*/HazLoc*; 4 ATEX*/IECEx*

Data sheet and additional information, see: wago.com/750-363/040-000

*pending

Page 60: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

58 Supplementary Catalog – Automation Technology

Volume 3, Section 6 | I/O System – 750 XTR Series

Fieldbus Coupler Modbus TCP M12; 4th Generation; Extreme

Item Description Fieldbus Coupler Modbus TCP M12; 4th GenerationVersion ExtremeItem No. 750-364/040-010Order Text FC Modbus TCP M12; G4; XTR

Technical DataFieldbus Modbus (TCP, UDP)Protocols HTTP(S), BootP, DHCP, DNS, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x D-coded M12 socketNumber of fieldbus nodes on master (max.) Limited by ETHERNET specificationBaud rate 10/100 Mbit/sTransmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; Line length (max.): 100 mNumber of modules per node (max.) 64Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power

jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 500 mAPower consumption – system supply (5 V) 350 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 112 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLocApprovals (pending) 4 ATEX/IECExData sheet and additional information, see: wago.com/750-364/040-010

750-

364/

040-

010

ABCD

ETHX2

ETHX1

I/O

NS

MS

LINKACT 1LINKACT 2

x1

x16

00: WBMFF: DHCP

ADDRESS0FEDC B A98765

43

21

0FEDC B A9876543

21 24V 0V

+ +

— —

01 02

Fieldbus connectionETHERNET M12

Fieldbus connectionETHERNET M12

Address

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Page 61: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

59Supplementary Catalog – Automation Technology

Volume 3, Section 6 | I/O System – 750 XTR Series

Fieldbus Coupler EtherNet/IPTM M12; 4th Generation; Extreme

Item Description Fieldbus Coupler EtherNet/IPTM M12; 4th GenerationVersion ExtremeItem No. 750-365/040-010Order Text FC EtherNet/IP M12; G4; XTR

Technical DataFieldbus EtherNet/IPTM

Protocols HTTP(S), BootP, DHCP, DNS, (S)FTP, SNMPConnection technology: fieldbus input/output 2 x D-coded M12 socketNumber of fieldbus nodes on master (max.) Limited by ETHERNET specificationBaud rate 10/100 Mbit/sTransmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; Line length (max.): 100 mNumber of modules per node (max.) 64Input/output (internal) process image (max.) 1020 words / 1020 wordsSupply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power

jumper contacts; Derating must be observed!Derating (supply voltage) Surrounding air temperature under laboratory conditions: (−25 … +30 %);

For −40 … +55 °C: 24 V (−25 … +20 %);For +55 … +70 °C: 24 V (−25 … +10 %);

Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)Input current (typ.) at nominal load (24 V) 500 mAPower consumption – system supply (5 V) 350 mATotal current (system supply) 1700 mASurrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 112 x 71.9 x 100 mm

Approvals 1; Marine; r OrdLoc/HazLocApprovals (pending) 4 ATEX/IECExData sheet and additional information, see: wago.com/750-365/040-010

750-

365/

040-

010

ABCD

ETHX2

ETHX1

I/O

NS

MS

LINKACT 1LINKACT 2

x1

x16

00: WBMFF: DHCP

ADDRESS0FEDC B A98765

43

21

0FEDC B A9876543

21 24V 0V

+ +

— —

01 02

Fieldbus connectionETHERNET M12

Fieldbus connectionETHERNET M12

Address

Supp

ly vo

ltage

(sys

tem

)Su

pply

volta

ge (fi

eld)

Page 62: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

60 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

WAGO I/O System Field

Integrated Load Management

Innovative load management ensures that the system’s power is fully utilized via sup-ply and output current load management. Current and voltage can be recorded and evaluated per channel. Overload limits can be set for individual channels. As a result, errors can be detected faster and more clearly differentiated in the event of faults – errors are also more easily predicted, which is essential for future topics such as predictive maintenance.

All-in-One Solution via IO-Link

In combination with IO-Link, the I/O System Field fully demonstrates its strengths as a flexible “IO distributor” for both data collection and distribution. The prominent communication standard enables seamless data flow from the control to the sensor and actuator level. This considerably simplifies configuration and cabling. Furthermore, completely new possibilities arise for diagnostics, parameterization and device identification.  

General Product Information

Advantages:

• Platform-independent data exchange through OPC UA• System information provided via MQTT• Fast on-site access to data through Bluetooth®• Status information of the system via integrated Webserver• Ready for future TSN implementation• Fully encapsulated IP67 metal housings for extreme environments• Non-encapsulated, lightweight IP67 plastic housings for mobile applications• WAGO standard marking (WMB Inline markers and marking strips)

Automate and Network Modular Machines for the Future

High performance, designed for time-sensitive networking (TSN) and un-shakeable in the harshest environmental conditions: The WAGO I/O System Field for cabinet-free automation with IP67 protection and an impressive variety of functions.

Extended Network Connectivity

Modern, decentralized production facil-ities require automation solutions that ensure the highest level of connectivity while providing maximum performance outside the control cabinet.

WAGO developed its upgradable I/O System Field with IP67 protection to meet these needs today and tomorrow: It combines fast ETHERNET-based fieldbuses such as PROFINET, technol-ogies such as OPC UA, Bluetooth® and Webserver, and MQTT as a protocol for cloud connectivity.

Combines Functionality and Aesthetics

The IP67 I/O System Field offers no-compromise protection with pres-sure cast zinc housings for extremely harsh environments, or robust and lightweight plastic housings for mobile applications. The modules operate reli-ably at temperatures from −25 to +70°C (−13 … +158°F) and, thanks to internal shielding, are immune to electromag-netic interference. Slim housing variants and lateral mounting options open up more space.

Industrial Ethernet and PROFINET on the field level provide the basis for digitalization with WAGO I/O Sys-tem Field. EtherNet/IPTM and EtherCAT® are planned in as ETHERNET-based standards and the I/O System Field is #made for TSN (Time-Sensitive Networking).

The WAGO I/O System Field supports MQTT as an open message protocol for data transmission.

Equipped with an OPC UA server, OPC UA clients can access the widest range of device data, e.g., parameter data, status information, identification and diagnostics data as well as containers.

Fieldbus modules equipped with IO-Link masters and IO-Link hubs as devices facilitate effective, versatile connection of intelligent sensors/actuators to the automation system.

An app which enables direct access to a WAGO Field Device by identifi-cation of a data matrix code and through communication via BLE (Bluetooth® Low Energy) is available for wireless access with a mobile device.

An integrated Webserver enables HTTP and HTTPS communication. With this capability, many different kinds of system information can be accessed with popular commercial browsers.

Page 63: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

61Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

PROFINET

®

OPC UA

DIO

Sensors/

Actuators

PROFINET

®

OPC UA

IO-Link Master

IO-Link Sensors/

Actuators

IO-Link

IO-Link

Hub

Sensors/

Actuators

A a)b)

c)

d)

B

d)

e)

C a)b)

c)

d)

D a)b)

c)

d)

E a)

b)

F a)

b)

c)

a)b)

c)

I/O System FieldInterfaces and Types

Fieldbus Module as PROFINET Slave

• 16 DI, 16 DO or 16 DIO, with A-coded M12; 5-pole

• 8 DIO with A-coded M12; 5-pole or M8; 3-pole

IO-Link Master as PROFINET Slave

• with A-coded M12; 5-pole• 8 or 4 IO-Link ports, Class A• 8 or 4 IO-Link ports, Class B

IO-Link Hub

• 16 DIO with A-coded M12; 5-pole• 8 DIO with A-coded M12; 5-pole or

M8; 3-pole

Housing Design (A) • Fieldbus: 2 x D-coded M12; 5-pole (a) • Bluetooth® (b)• Supply: L-coded M12; 5-pole (c) • Inputs/Outputs: A-coded M12; 5-pole (d) • W x H x D (mm): 60 x 30 x 210

Housing Design (B)• Fieldbus: 2 x D-coded M12; 5-pole (a) • Bluetooth® (b)• Supply: L-coded M12; 5-pole (c) • Inputs/Outputs: A-coded M12; 5-pole (d) or M8;

3-pole (e)• W x H x D (mm): 35 x 30 x 210

Housing Design (C) • Fieldbus: 2 x D-coded M12; 5-pole (a) • Bluetooth® (b)• Supply: L-coded M12; 5-pole (c) • IO-Link ports: A-coded M12; 5-pole (d) • W x H x D (mm): 60 x 30 x 210

Housing Design (D)• Fieldbus: 2 x D-coded M12; 5-pole (a) • Bluetooth® (b)• Supply: L-coded M12; 5-pole (c) • IO-Link ports: A-coded M12; 5-pole (d)• W x H x D (mm): 35 x 30 x 210

Housing Design (E)• IO-Link hub: A-coded M12; 5-pole (a) • Inputs/Outputs: A-coded M12; 5-pole (b) • W x H x D (mm): 60 x 30 x 158.5

Housing Design (F) • IO-Link hub: A-coded M12; 5-pole (a) • Inputs/Outputs: A-coded M12; 5-pole (b) or M8;

3-pole (c)• W x H x D (mm): 35 x 30 x 158.5

Page 64: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

62 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-1101/0100-0000

SYS

BFSF

POWER

X02

1L

2

6

10

14

3

7

11

15

2L

X04

X06

X08

X010

4

8

12

1

5

9

13

X03

X05

X07

P

N E T

R O F I

4

3

21

FE

1L+/1L-

DI

4

3

21

FE

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

1L+/1L-

DI

DI

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1, 3, … 15

2, 4, … 16

1 2

4

5 5

3

2 3

1 4

1: 1L+3: 1L-

4: DI A2: DI B

- + - +

DI 1, DI 2

DI 5, DI 6

DI 9, DI 10

DI 13, DI 14

PROFINET input 2PROFINET input 1

DI 3, DI 4

DI 7, DI 8

DI 11, DI 12

DI 15, DI 16

Mounting holes

DM code

Bluetooth®

Channel marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

Power supply: 1L

Output Input

X01 ... X08Digital inputs

16-Channel Digital Input; I/O System Field; PROFINET Slave; 24 VDC; 8 x M12 Connector

Item Description 16-Channel Digital Input; I/O System Field; PROFINET Slave; 24 VDCVersion 8 x M12 connectorItem No. 765-1101/100-000Order Text 16DI FLD PN DC 24V

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

Digital InputsNumber of digital inputs 16Connection technology: inputs A-coded M12; 5-poleSignal type (voltage) 24 VDCSensor current 2 A (max.) per channelInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1101/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

» Power Cable; ETHERNET/PROFINET Cablesee page 76 and 77

Page 65: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

63Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-1103/0100-0000

SYS

BFSF

POWER

X02

1L

2

6

10

14

3

7

11

15

2L

X04

X06

X08

X010

4

8

12

1

5

9

13

X03

X05

X07

P

N E T

R O F I

4

3

21

FE

DO

4

3

21

FE

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

DO

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1, 3, … 15

2, 4, … 16

1 2

4

5 5

3

2 3

1 4

3: 2L-

4: DO A2: DO B

- + - +

DO 1, DO 2

DO 5, DO 6

DO 9, DO 10

DO 13, DO 14

PROFINET input 2PROFINET input 1

DO 3, DO 4

DO 7, DO 8

DO 11, DO 12

DO 15, DO 16

Mounting holes

DM code

Bluetooth®

Channel marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

Power supply: 2L

Output Input

X01 ... X08Digital outputs

16-Channel Digital Output; I/O System Field; PROFINET Slave; 24 VDC; 8 x M12 Connector

Item Description 16-Channel Digital Output; I/O System Field; PROFINET Slave; 24 VDCVersion 8 x M12 connectorItem No. 765-1103/100-000Order Text 16DO FLD PN DC 24V

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

Digital OutputsNumber of digital outputs 16Connection technology: outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCOutput current 2 A (max.) per channel for DOSupply current per port 2L: max. 4 A

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1103/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 66: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

64 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-1102/0100-0000

SYS

BFSF

POWER

X02

1L

2

6

10

14

3

7

11

15

2L

X04

X06

X08

X010

4

8

12

1

5

9

13

X03

X05

X07

P

N E T

R O F I

4

3

21

FE

1L+/1L-

DIO

4

3

21

FE

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

9, 11, 13, 151, 3, 5, 7

2, 4, 6, 810, 12, 14, 16

1 2

45 5

3

2 3

1 4

1: 1L+/2L+3: 1L-/2L-

4: DIO A2: DIO B

- + - +

X05 ... X08

1 2

45 5

3

2 3

1 4

DIO 1, DIO 2

DIO 5, DIO 6

DIO 9, DIO 10

DIO 13, DIO 14

PROFINET input 2PROFINET input 1

DIO 3, DIO 4

DIO 7, DIO 8

DIO 11, DIO 12

DIO 15, DIO 16

Mounting holes

DM code

Bluetooth®

Channel marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

Power supply: 1L/2L

Output InputX01 ... X04

Digital inputs/outputs

16-Channel Digital Input/Output; I/O System Field; PROFINET Slave; 24 VDC; 8 x M12 Connector

Item Description 16-Channel Digital Input/Output; I/O System Field; PROFINET Slave; 24 VDCVersion 8 x M12 connectorItem No. 765-1102/100-000Order Text 16DIO FLD PN DC 24V

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

Digital Inputs/OutputsNumber of digital inputs/outputs 16Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L/2L: max. 4 A

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1102/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

» Power Cable; ETHERNET/PROFINET Cablesee page 76 and 77

Page 67: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

65Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-1104/0100-0000

SYS

BFSF

POWER

X01

1L

0

2

4

6

1

3

5

7

2L

X02

X03

X04

P

N E T

R O F I

4

3

21

FE 4

3

21

FE

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1, 3, 5, 7

2, 4, 6, 8

4: DIO A

2: DIO B

1: 1L+/2L+

3: 1L-/2L-

- + - +

DIO 1, DIO 2

DIO 5, DIO 6

DIO 7, DIO 8

DIO 3, DIO 4

5

2 3

1 4

X03 ... X04

5

2 3

1 4

X01 ... X02

Power supply: 1L/2L

Output Input

Digital inputs/outputs

LNK

LNK

ACT

ACT

765-1105/0100-0000

SYS

BFSF

POWER

1L

2L

X02

X04

X06

X08

X07

X05

X03

X01

P

N E T

R O F I

4

3

21

FE

1L+/1L-

DIO

4

3

21

FE

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1

3

5

7

0

2

4

6

4: DIO

1: 1L+/2L+

3: 1L-/2L-

- +

X05 ... X08

X01 ... X04

3 41

4 13

3 41

4 13

1 … 4, 5 … 8

DIO 1

DIO 3

DIO 5

DIO 7

DIO 2

DIO 4

DIO 6

DIO 8

Power supply: 1L/2L

Output Input

Digital inputs/outputs

8-Channel Digital Input/Output; I/O System Field; PROFINET Slave; 24 VDC

Item Description 8-Channel Digital Input/Output; I/O System Field; PROFINET Slave; 24 VDCVersion 4 x M12 connector 8 x M8 connectorItem No. 765-1104/100-000 765-1105/100-000Order Text 8DIO FLD PN DC 24V 8DIO FLD PN DC 24V

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

Digital Inputs/OutputsNumber of digital inputs/outputs 8Connection technology: inputs/outputs A-coded M12; 5-pole M8; 3-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L/2L: max. 4 A

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1104/100-000 wago.com/765-1105/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Figure: 765-1104/100-000

Figure: 765-1105/100-000

Page 68: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

66 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-4101/0100-0000

SYS

BFSF

POWER

X02

1L

2

6

10

14

3

7

11

15

2L

X04

X06

X08

X010

4

8

12

1

5

9

13

X03

X05

X07

P

N E T

R O F I

A

A

A

A A

A

A

A

4

3

21

FE

1L+/1L-

2L+/2L-

DIO

4

3

21

FE

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1 2

4 3

2 3

1 4

1: 1L+3: 1L-

4: C/Q DIO A (DI/DQ)

2: DIO B (DI/DQ)

5 5

- + - +

Port 1

IO-Link Class A

Port 3

Port 5

Port 7

PROFINET input 2PROFINET input 1

Port 2

Port 4

Port 6

Port 8

Mounting holes

DM code

Bluetooth®

Port marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

X01 ... X08IO-Link Class A Port

Power supply: 1L

Output Input

8-Port IO-Link Master Class A; I/O System Field; PROFINET; 24 VDC 2.0 A; 8 x M12 Connector

Item Description 8-Port IO-Link Master Class A; I/O System Field; PROFINET; 24 VDC 2.0 AVersion 8 x M12 connectorItem No. 765-4101/100-000Order Text 8PORT IOL-A FLD PN DC 24V 2.0A

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

IO-Link Master Class A Specification V1.1Port mode IO-Link: autoconfig, manual, tool-based; DI; DOCycle time 400 μs (min.)Operating modes IO-Link master, DI or DO (adjustable for pin 4 per port); DI or DO (adjustable for pin 2 per port)

IO-Link PortsNumber of digital inputs/outputs 16Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L: 1 A for IO-Link; 4 A (max.) for DIO

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-4101/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

» Power Cable; ETHERNET/PROFINET Cablesee page 76 and 77

Page 69: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

67Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-4102/0100-0000

SYS

BFSF

POWER

X02

1L

2

6

10

14

3

7

11

15

2L

X04

X06

X08

X010

4

8

12

1

5

9

13

X03

X05

X07

P

N E T

R O F I

B

B

B

B B

B

B

B

4

3

21

FE

1L+/1L-

2L+/2L-

4

3

21

FE

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1 2

45 5

3

2 3

1 4

1: 1L+ 2: 2L+

5: 2L-3: 1L-

4: C/Q DIO A (DI/DQ)

- +

Port 1

IO-Link Class B

Port 3

Port 5

Port 7

PROFINET input 2PROFINET input 1

Port 2

Port 4

Port 6

Port 8

Mounting holes

DM code

Bluetooth®

Port marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

X01 ... X08IO-Link Class B Port

Power supply: 1L/2L

Output Input

8-Port IO-Link Master Class B; I/O System Field; PROFINET; 24 VDC 2.0 A; 8 x M12 Connector

Item Description 8-Port IO-Link Master Class B; I/O System Field; PROFINET; 24 VDC 2.0 AVersion 8 x M12 connectorItem No. 765-4102/100-000Order Text 8PORT IOL-B FLD PN DC 24V 2.0A

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

IO-Link Master Class B Specification V1.1Port mode IO-Link: autoconfig, manual, tool-based; DI; DOCycle time 400 μs (min.)Operating modes IO-Link master, DI or DO (adjustable for pin 4 per port); Supply voltage 2L (fixed for pin 2 per port)

IO-Link PortsNumber of digital inputs/outputs 16Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput/output characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L: 1 A for IO-Link; 4 A (max.) for DIO; 2L (via pin 2): 4 A (max.)

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-4102/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 70: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

68 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-4103/0100-0000

SYS

BFSF

POWER

X01

1L

0

2

4

6

1

3

5

7

2L

X02

X03

X04

P

N E T

R O F I

A

A

A

A

4

3

21

FE 2L+/2L- 4

3

21

FE

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

DIO

C/Q

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1 2

4 3

2 3

1 45 5

- + - +

1: 1L+3: 1L-

4: C/Q DIO A (DI/DQ)

2: DIO B (DI/DQ)

IO-Link Class A

PROFINET input 2PROFINET input 1

Port 1

Port 2

Port 3

Port 4

Mounting holes

DM code

Bluetooth®

LED indicators (module)

Module marking

X01 ... X04IO-Link Class A Port

Port marking (WMB Inline)

LED indicators (channel)

Power supply: 1L

Output Input

4-Port IO-Link Master Class A; I/O System Field; PROFINET; 24 VDC 2.0 A; 4 x M12 Connector

Item Description 4-Port IO-Link Master Class A; I/O System Field; PROFINET; 24 VDC 2.0 AVersion 4 x M12 connectorItem No. 765-4103/100-000Order Text 4PORT IOL-A FLD PN DC 24V 2.0A

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

IO-Link Master Class A Specification V1.1Port mode IO-Link: autoconfig, manual, tool-based; DI; DOCycle time 400 μs (min.)Operating modes IO-Link master, DI or DO (adjustable for pin 4 per port); DI or DO (adjustable for pin 2 per port)

IO-Link PortsNumber of digital inputs/outputs 8Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L: 1 A for IO-Link; 4 A (max.) for DIO

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-4103/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

» Power Cable; ETHERNET/PROFINET Cablesee page 76 and 77

Page 71: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

69Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

LNK

LNK

ACT

ACT

765-4104/0100-0000

SYS

BFSF

POWER

X01

1L

0

2

4

6

1

3

5

7

2L

X02

X03

X04

P

N E T

R O F I

B

B

B

B

4

3

21

FE 4

3

21

FE

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

1L+/1L-

2L+/2L-

C/Q

2L+/2L-

1L+/1L-

FLDAPL

X31

X32

X21

X22 BT

1 2

45 5

3

2 3

1 4

1: 1L+ 2: 2L+

5: 2L-3: 1L-

4: C/Q DIO A (DI/DQ)

- +IO-Link Class B

PROFINET input 2PROFINET input 1

Port 1

Port 2

Port 3

Port 4

Mounting holes

DM code

Bluetooth®

Port marking (WMB Inline)

LED indicators (module)

LED indicators (channel)

Module marking

Power supply: 1L/2L

Output Input X01 ... X04IO-Link Class B Port

4-Port IO-Link Master Class B; I/O System Field; PROFINET; 24 VDC 2.0 A; 4 x M12 Connector

Item Description 4-Port IO-Link Master Class B; I/O System Field; PROFINET; 24 VDC 2.0 AVersion 4 x M12 connectorItem No. 765-4104/100-000Order Text 4PORT IOL-B FLD PN DC 24V 2.0A

Technical DataFieldbus

Communication interface PROFINETConnection technology: Fieldbus D-coded M12; 4-poleInterface type 10BASE-T/100BASE-TX; potential-freeAutonegotiation; Autocrossover YesPROFINET IO features PROFINET IO device; 2-port switch, LLDP, MRP, SNMP

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; OvertemperatureDevice Functions Bluetooth®; MQTT; OPC UA serverVisualization Android/iOS app; Webserver

IO-Link Master Class B Specification V1.1Port mode IO-Link: autoconfig, manual, tool-based; DI; DOCycle time 400 μs (min.)Operating modes IO-Link master, DI or DO (adjustable for pin 4 per port); Supply voltage 2L (fixed for pin 2 per port)

IO-Link PortsNumber of digital inputs/outputs 8Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput/output characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A (typ.) per channel for DOSupply current per port 1L: 1 A for IO-Link; 4 A (max.) for DIO; 2L (via pin 2): 4 A (max.)

Module Power SupplyConnection technology: power supply L-coded M12; 5-poleSupply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 16 A (max.) per supply line; overload- and short-circuit-protectedReverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 210 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-4104/100-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 72: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

70 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1701/0200-0000

X010

2

4

6

1

3

5

7

X02

X03

X04

X21

A

1L+/1L-

DIO

DIO

1L+/1L-

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1, 3, 5, 7

2, 4, 6, 8

1 2

45 5

3

2 3

1 4

1: 1L+3: 1L-

4: DIO A2: DIO B

- + - +

Power supply: 1L

DIO 1, DIO 2

DIO 3, DIO 4

DIO 5, DIO 6

DIO 7, DIO 8

Mounting holes

X01 ... X04Digital inputs/outputs

IO-Link Class A PortModule marking

DM code

Channel marking (WMB Inline)

LED indicators (channel)

8-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 A; 4 x M12 Connector

Item Description 8-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 AVersion 4 x M12 connectorItem No. 765-1701/200-000Order Text 8DIO FLD IOL-A HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class A SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 8Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L)Supply voltage 1L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A + load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1701/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 73: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

71Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1704/0200-0000

X010

2

4

6

1

3

5

7

X02

X03

X04

X21

B

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

1L+/1L-

1, 3, 5, 7

2, 4, 6, 8

1: 1L+/2L+3: 1L-/2L-

4: DIO A2: DIO B

- + - +

5

2 3

1 4

X03 ... X04

5

2 3

1 4

Power supply: 1L/2L

X01 ... X02Digital inputs/outputs

DIO 1, DIO 2

DIO 3, DIO 4

DIO 5, DIO 6

DIO 7, DIO 8

Mounting holes

IO-Link Class B PortModule marking

DM code

Channel marking (WMB Inline)

LED indicators (channel)

8-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 A; 4 x M12 Connector

Item Description 8-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 AVersion 4 x M12 connectorItem No. 765-1704/200-000Order Text 8DIO FLD IOL-B HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class B SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 4Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L/2L)Supply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A; 2L: 0.1 A; + load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1704/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 74: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

72 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1702/0200-0000

X21

A

X02

X04

X06

X08

X07

X05

X03

X01

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

1

3

5

7

0

2

4

6

1: 1L+3: 1L-

4: DIO

3 41

4 13

- +

Mounting holes

IO-Link Class A PortModule marking

DM code

Channel marking (WMB Inline)

LED indicators (channel)

X01 ... X08Digital inputs/outputs

DIO 1

DIO 3

DIO 5

DIO 7

DIO 2

DIO 4

DIO 6

DIO 8

Power supply: 1L

8-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 A; 8 x M8 Connector

Item Description 8-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 AVersion 8 x M8 connectorItem No. 765-1702/200-000Order Text 8DIO FLD IOL-A HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class A SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 8Connection technology: inputs/outputs M8; 3-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L)Supply voltage 1L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A + load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1702/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 75: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

73Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1705/0200-0000

X21

B

1

3

5

7

0

2

4

6

X02

X04

X06

X08

X07

X05

X03

X01

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

1L+/1L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

DIO

2L+/2L-

1L+/1L-

1: 1L+/2L+3: 1L-/2L-

4: DIO

3 41

4 13

- +

1 … 4, 5 … 8

X05 ... X08

3 41

4 13

Mounting holes

IO-Link Class B PortModule marking

DM code

Channel marking (WMB Inline)

LED indicators (channel)

X01 ... X04Digital inputs/outputs

DIO 1

DIO 3

DIO 5

DIO 7

DIO 2

DIO 4

DIO 6

DIO 8

Power supply: 1L/2L

8-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 A; 8 x M8 Connector

Item Description 8-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 AVersion 8 x M8 connectorItem No. 765-1705/200-000Order Text 8DIO FLD IOL-B HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class B SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 4Connection technology: inputs/outputs M8; 3-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L/2L)Supply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A; 2L: 0.1 A; load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 35 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1705/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 76: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

74 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1703/0200-0000

X020

2

4

6

1

3

5

7

X04

X06

X08

X21

A

X010

4

8

12

1

5

9

13

X03

X05

X07

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

1, 3, … 15

2, 4, … 16

1 2

45 5

3

2 3

1 4

1: 1L+3: 1L-

4: DIO A2: DIO B

- + - +

DIO 1, DIO 2

DIO 5, DIO 6

DIO 9, DIO 10

DIO 13, DIO 14

DIO 3, DIO 4

DIO 7, DIO 8

DIO 11, DIO 12

DIO 15, DIO 16

Mounting holes

X01 ... X08Digital inputs/outputs

Power supply: 1LIO-Link Class A PortModule marking

DM codeChannel marking

(WMB Inline)LED indicators (channel)

16-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 A; 8 x M12 Connector

Item Description 16-Channel Digital Input/Output; I/O System Field; IO-Link Class A Hub; 24 VDC 2.0 AVersion 8 x M12 connectorItem No. 765-1703/200-000Order Text 16DIO FLD IOL-A HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class A SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 16Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L)Supply voltage 1L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A + load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1703/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 77: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

75Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

IOL

2L

765-1706/0200-0000

X020

2

4

6

1

3

5

7

X04

X06

X08

X21

B

X010

4

8

12

1

5

9

13

X03

X05

X07

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

1L+/1L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

DIO

DIO

2L+/2L-

1L+/1L-

DIO 1, DIO 2

DIO 5, DIO 6

DIO 9, DIO 10

DIO 13, DIO 14

DIO 3, DIO 4

DIO 7, DIO 8

DIO 11, DIO 12

DIO 15, DIO 16

Mounting holes

X01 ... X08Digital inputs/outputs

IO-Link Class B PortModule marking

DM codeChannel marking

(WMB Inline)LED indicators (channel)

Power supply: 1L/2L

1 2

45 5

3

2 3

1 4

1: 1L+/2L+3: 1L-/2L-

4: DIO A2: DIO B

- + - +

9, 11, 13, 151, 3, 5, 7

2, 4, 6, 810, 12, 14, 16

X05 ... X08

1 2

45 5

3

2 3

1 4

16-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 A; 8 x M12 Connector

Item Description 16-Channel Digital Input/Output; I/O System Field; IO-Link Class B Hub; 24 VDC 2.0 AVersion 8 x M12 connectorItem No. 765-1706/200-000Order Text 16DIO FLD IOL-B HUB DC 24V 2.0A

Technical DataIO-Link

Communication interface IO-Link Class B SlaveConnection technology: IO-Link A-coded M12; 5-pole

Device FunctionsParameters Input filter; Output current; TemperatureDiagnostics Undervoltage; Overcurrent; Overload; Overtemperature

Digital Inputs/OutputsNumber of digital inputs/outputs 8Connection technology: inputs/outputs A-coded M12; 5-poleSignal type (voltage) 24 VDCInput characteristic High-side switchingInput filter 0.2 … 20 msInput characteristic Type 3; per IEC 61131-2Output current 2 A per channel

Power SupplyConnection technology: power supply A-coded M12; 5-pole; via IO-Link port (1L/2L)Supply voltage 1L/2L: 24 VDC (-25 … +30 %)Power consumption 1L: 0.2 A; 2L: 0.1 A; + load current; 4 A (max.)Reverse voltage protection Yes

Surrounding air temperature (operation) -25 … +70 °CDimensions W x H x D 60 x 30 x 158.5 mm

Approvals 1Approvals (pending) r OrdLocData sheet and additional information, see: wago.com/765-1706/200-000

Accessories Item No.Marking strips 2009-110

WMB-Inline 2009-115

Page 78: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

76 Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

M12 socket M12 plug

43 2

1FE

432

1FE Pin 1 … 4/FE: 1.5 mm²

1 brown2 white3 blue4 blackFE gray

L*58

(mm)SW13

ø15

(mm)

L*40

35

ø15

SW13

L*63

ø15

(mm)SW13

(mm)

L*40

40

ø15

SW13

(mm)

L*58 63

ø15 ø15

SW13 SW13

(mm)

L*

SW13

40 40

40SW13

35

ø15ø15

Operating voltage 60 VDCOperating current 16 A / 40 °C (max.)Surrounding air temperature (operation)

-30 … +90 °C

Protection class IP67Cable diameter 9.9 mm ±0.3

Power cable; pre-assembled on one end; M12 straight socket; L-codedCable length Item No. Pack. Unit2 m 756-3501/050-020 15 m 756-3501/050-050 17.5 m 756-3501/050-075 110 m 756-3501/050-100 115 m 756-3501/050-150 1

Power cable; pre-assembled on one end; M12 angled socket; L-codedCable length Item No. Pack. Unit2 m 756-3502/050-020 15 m 756-3502/050-050 17.5 m 756-3502/050-075 110 m 756-3502/050-100 115 m 756-3502/050-150 1

Power cable; pre-assembled on one end; M12 straight plug; L-codedCable length Item No. Pack. Unit2 m 756-3503/050-020 15 m 756-3503/050-050 17.5 m 756-3503/050-075 110 m 756-3503/050-100 115 m 756-3503/050-150 1

Power cable; pre-assembled on one end; M12 angled plug; L-codedCable length Item No. Pack. Unit2 m 756-3504/050-020 15 m 756-3504/050-050 17.5 m 756-3504/050-075 110 m 756-3504/050-100 115 m 756-3504/050-150 1

Power cable; pre-assembled on both ends; M12 straight socket/M12 straight plug; L-codedCable length Item No. Pack. Unit0.3 m 756-3505/050-003 10.5 m 756-3505/050-005 11 m 756-3505/050-010 12 m 756-3505/050-020 15 m 756-3505/050-050 17.5 m 756-3505/050-075 110 m 756-3505/050-100 115 m 756-3505/050-150 1

Power cable; pre-assembled on both ends; M12 angled socket/M12 angled plug; L-codedCable length Item No. Pack. Unit0.3 m 756-3506/050-003 10.5 m 756-3506/050-005 11 m 756-3506/050-010 12 m 756-3506/050-020 15 m 756-3506/050-050 17.5 m 756-3506/050-075 110 m 756-3506/050-100 115 m 756-3506/050-150 1

Power Cable; L-Coded; 5-Pole

Page 79: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

77Supplementary Catalog – Automation Technology

Volume 3 | I/O System Field

M12 plug

4

1

3

2

Pin 1 - 4: 0.34 mm²

1 yellow2 white3 orange4 blue

L*)52,3 35±2

(mm)

ø15

M12

x1

SW13

35,3

L*)37,5 35±2

(mm)

ø15M12x1

SW13

L*)52,3

ø15

M12

x1

52,3

ø15

M12

x1

(mm)SW13 SW13

L*)

35,3

37,5

35,3

37,5

ø15M12x1

ø15M12x1

(mm)

SW13 SW13

Operating voltage 250 VOperating current 4 ARated surge voltage 2 kVDrag chain suitability ≥ 3 million bending cyclesSurrounding air (operating) temperature (dynamic)

−40 … +70 °C

Protection class IP67Cable diameter 6.5 mm ±0.2

ETHERNET/PROFINET cable; pre-assembled on one end; M12 straight plug; D-codedCable length Item No. Pack. Unit2 m 756-1201/060-020 15 m 756-1201/060-050 110 m 756-1201/060-100 120 m 756-1201/060-200 1

ETHERNET/PROFINET cable; pre-assembled on one end; M12 angled plug; D-codedCable length Item No. Pack. Unit2 m 756-1202/060-020 15 m 756-1202/060-050 110 m 756-1202/060-100 115 m 756-1202/060-200 1

ETHERNET/PROFINET cable; pre-assembled on both ends; M12 plug – M12 plug; straight; D-codedCable length Item No. Pack. Unit2 m 756-1203/060-020 15 m 756-1203/060-050 110 m 756-1203/060-100 120 m 756-1203/060-200 1

ETHERNET/PROFINET cable; pre-assembled on both ends; M12 plug – M12 plug; angled; D-codedCable length Item No. Pack. Unit2 m 756-1204/060-020 15 m 756-1204/060-050 110 m 756-1204/060-100 120 m 756-1204/060-200 1

ETHERNET/PROFINET Cable; D-coded; 4-pole

Page 80: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

78 Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Industrial Managed Switch; 8-port 1000BASE-T; 4-slot 1000BASESX/LX; Extended temperature range; USB

Item Description Industrial Managed Switch; 8-port 1000BASE-T; 4-slot 1000BASESX/LX; Extended temperature range; USB

Item No. 852-1305/000-001Order Text Industrial Managed Switch; 8Port 1000BASE-T; 4Slot 1000BASE-SX/LX; EXT; USB

Technical DataSwitching mode Store‐and‐forward, non-blockingNumber of copper ports 8 x 1000BASE-TNumber of FOC ports 4 x 1000BASE-SX/LXCommunication standards IEEE 802.3 10BASE-T;

IEEE 802.3u 100BASE-TX;IEEE 802.3ab 1000BASE-T;

IEEE 802.3z 1000BASE-SX/LX;IEEE 802.3x Flow Control;

IEEE 802.1d Spanning Tree Protocol (STP);IEEE 802.1w Rapid Spanning Tree Protocol (RSTP);

IEEE 802.1s Multiple Spanning Tree Protocol (MSTP);IEEE 802.1Q VLAN Tagging;IEEE 802.1p Prioritization;

IEEE 802.1x Port Authentication;IEEE 802.1ab Link Layer Discovery Protocol (LLDP);

IEEE 802.3ad Link Aggregation;IEEE 1588v2 Precision Time Protocol (PTP);

ITU-T G8032v1/v2 Ethernet Ring Protection Switching (ERPS)Redundancy functions Redundant DC power supply; STP; RSTP; MSTP; Jet Ring < 300 ms;

Xpress Ring < 20 ms; Dual Homing < 20 ms; Dual Ring; ERPSv2 < 50 ms; LCAP

Configuration DIP switch for signal contact; Web-Based-Management; Command Line Interface; SNMPv1/v2c/v3; USB storage medium

Diagnostics Signal contact; Modbus TCP; Port status; Port statistics; Port load; Traffic monitor; SFP information; Syslog; Mail alarm; SNMP traps; Loop detection; …

MAC table (large) 16,000 addressesJumbo frame size 10 KBSupply voltage 12 … 48 VDCPower consumption (max.) 18 WESD (contact/air discharge) 8 KV / 15 KVConnection technology (communication) 8 x RJ-45; 4 x SFP; 1 x RJ-45 (RS-232)Surrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 50 x 120 x 162 mm

Approvals 1; r OrdLocData sheet and further information, see: wago.com/852-1305/000-001

11

ALMPWR

RPS

12

9 10

1000M

10/100M

USB

(FAT

32)

9 10 1211SFP

POST

852-1305/000-001852 1305/00

RS2

32 C

ON

SOLE

1

3

5

7

2

4

6

8

TX-Ports 10/100/1000 Mbit/s

1000BASE-SX/LX, LC, Fiber Optic (SFP-type)

USB storage medium

RS-232 Port (RJ-45)

Page 81: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

79Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Industrial Managed Switch; 8-port 1000BASE-T; 4-slot 1000BASESX/LX; Extended temperature range; 8 * Power over Ethernet; USB

Item Description Industrial Managed Switch; 8-port 1000BASE-T; 4-slot 1000BASESX/LX; Extended temperature range; 8 * Power over Ethernet; USB

Item No. 852-1505/000-001Order Text Industrial Managed Switch; 8Port 1000BASE-T; 4Slot 1000BASE-SX/LX; EXT; 8PoE; USB

Technical DataSwitching mode Store‐and‐forward, non-blockingNumber of copper ports 8 x 1000BASE-T; 8 x PoE+ (Power over Ethernet)Number of FOC ports 4 x 1000BASE-SX/LXCommunication standards IEEE 802.3 10BASE-T;

IEEE 802.3u 100BASE-TX;IEEE 802.3ab 1000BASE-T;

IEEE 802.3z 1000BASE-SX/LX;IEEE 802.3x Flow Control;

IEEE 802.1d Spanning Tree Protocol (STP);IEEE 802.1w Rapid Spanning Tree Protocol (RSTP);

IEEE 802.1s Multiple Spanning Tree Protocol (MSTP);IEEE 802.1Q VLAN Tagging;IEEE 802.1p Prioritization;

IEEE 802.1x Port Authentication;IEEE 802.1ab Link Layer Discovery Protocol (LLDP);

IEEE 802.3ad Link Aggregation;IEEE 1588v2 Precision Time Protocol (PTP);

IEEE 802.3af Power over Ethernet (PoE);IEEE 802.3at High Power over Ethernet (PoE+);

ITU-T G8032v1/v2 Ethernet Ring Protection Switching (ERPS)Redundancy functions Redundant DC power supply; STP; RSTP; MSTP; Jet Ring < 300 ms; Xpress Ring < 20 ms; Dual Homing

< 20 ms; Dual Ring; ERPSv2 < 50 ms; LCAPConfiguration DIP switch for signal contact; Web-Based-Management; Command Line Interface; SNMPv1/v2c/v3; USB

storage mediumDiagnostics Signal contact; Modbus TCP; Port status; Port statistics; Port load; Traffic monitor; SFP information;

Syslog; Mail alarm; SNMP traps; Loop detection; …MAC table (large) 16,000 addressesJumbo frame size 10 KBSupply voltage 24 ... 57 VDCPower consumption (max.) 18 W; 258 W with 8 PoE+ESD (contact/air discharge) 8 KV / 15 KVConnection technology (communication) 8 x RJ-45; 4 x SFP; 1 x RJ-45 (RS-232)Surrounding air temperature (operation) −40 … +70 °C; −10 … +60 °C at UL 61010Dimensions W x H x D 50 x 120 x 162 mm

Approvals 1; r OrdLocData sheet and further information, see: wago.com/852-1505/000-001

11

ALMPWR

RPS

1 2 43

12

9 10

1000M

10/100M

PoE9 10 1211

SFP

5 6 87

POST

852-1505/000-001852 1505/00

1

3

5

7 8

2

4

6

RS2

32 C

ON

SOLE

USB

(FAT

32)

TX-Ports 10/100/1000 Mbit/s

1000BASE-SX/LX, LC, Fiber Optic (SFP-type)

USB storage medium

RS-232 Port (RJ-45)

Page 82: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

80 Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

1

3

2

4

852-1322

LNK/ACT

100M/1G

PWRRPS

ALM

5

7

6

8

TX-Ports 10/100/1000 Mbit/s

Industrial Managed Switch; 8 Ports 1000BASE-T; MAC Security

Item Description Industrial Managed Switch; 8 Ports 1000BASE-T; MAC SecurityItem No. 852-1322Order Text Managed Switch; 8Port Gb; MACsec

Technical DataSwitching mode Store‐and‐forward (non-blocking)Number of copper ports 8 x 10/100/1000BASE-T (RJ-45)Communication standards IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TXIEEE 802.3ab 1000BASE-TIEEE 802.3x Flow ControlIEEE 802.1p Prioritization

IEEE 802.1X Port AuthenticationIEEE 802.3az Energy Efficient Ethernet

IEEE 802.1AE MAC SecurityRedundancy functions Redundant DC power supplyConfiguration Web-based (HTTP(S)), SNMPv1/v2c/v3Diagnostics Modbus TCP; Port status; Syslog; SNMP trapsMAC table (large) 16,000 addressesSupply voltage 9 ... 48 VDCPower consumption (max.) 5.8 WESD (contact/air discharge) 8 KV / 15 KVConnection technology (communication) 8 x RJ-45Surrounding air temperature (operation) −20 … +70 °CDimensions W x H x D 45.3 × 92 × 110 mm

Approvals 1; r OrdLoc (E482462)Data sheet and additional information, see: wago.com/852-1322

Page 83: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

81Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

1

3

5

2

4

6

7

LNK/ACT

100M/1G

8

PWRRPS

ALM

852-1328

TX-Ports 100 Mbit/s/1 Gbit/s

1000BASE-FX, LC, Fiber Optic (SFP-type)

Industrial Managed Switch; 6 Ports 1000BASE-T; 2 Slots 1000BASE-SX/LX; MAC Security

Item Description Industrial Managed Switch; 6 Ports 1000BASE-T; 2 Slots 1000BASE-SX/LX; MAC SecurityItem No. 852-1328Order Text Managed Switch; 6Port Gb; 2FOC Gb; MACsec

Technical DataSwitching mode Store‐and‐forward (non-blocking)Number of copper ports 6 x 10/100/1000BASE-T (RJ-45)Number of FOC ports 2 x 1000BASE-SX/LX (SFP)Communication standards IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TXIEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-SX/LXIEEE 802.3x Flow ControlIEEE 802.1p Prioritization

IEEE 802.1X Port AuthenticationIEEE 802.3az Energy Efficient Ethernet

IEEE 802.1AE MAC SecurityRedundancy functions Redundant DC power supplyConfiguration Web-based (HTTP(S)), SNMPv1/v2c/v3Diagnostics Modbus TCP; Port status; Syslog; SNMP trapsMAC table (large) 16,000 addressesSupply voltage 9 ... 48 VDCPower consumption (max.) 5.8 WESD (contact/air discharge) 8 KV / 15 KVConnection technology (communication) 8 x RJ-45Surrounding air temperature (operation) −20 … +70 °CDimensions W x H x D 45.3 × 92 × 110 mm

Approvals 1; r OrdLoc (E482462)Data sheet and additional information, see: wago.com/852-1328

Page 84: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

82 Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Industrial Managed Switch; 8 Ports 100BASE-TX; PROFINET;Extended Temperature Range

Item Description Industrial Managed Switch; 8 Ports 100BASE-TX; PROFINET; Extended Temperature RangeItem No. 852-602Order Text Industrial Managed Switch; 8Port 100BASE-TX; PROFINET; T

Technical DataSwitching mode Store‐and‐forward (non-blocking)Number of copper ports 8 x 10/100Base-TXCommunication standards IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TXIEEE 802.3x Flow Control

IEEE 802.1d Spanning Tree Protocol (STP)IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)

IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)IEEE 802.1Q VLAN Tagging

IEEE 802.1p Class of ServiceIEEE 802.1ab Link Layer Discovery Protocol (LLDP)

PROFINET Conformance Class BRedundancy functions Redundant DC power supply; STP; RSTP; MSTP;

Media redundancy protocol as manager or clientConfiguration DIP switch for signal contact; Web-Based-Management; Command Line Interface; SNMPv1/v2/v3Diagnostics Signal contact; Port status; Port statistics; Port load; Traffic monitor; SFP information; Syslog; SNMP

traps; PN diagnostics (cyclic and acyclic)MAC table (large) 16000 addressesJumbo frame size 10 KBSupply voltage 12 ... 60 VDCPower consumption (max.) 12 WESD (contact/air discharge) 8 kV / 15 kVConnection technology (communication) 8 x RJ-45; 1 x RJ-45 (RS-232)Surrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 50 x 162 x 122 mm

Approvals 1; r OrdLocData sheet and additional information, see: wago.com/852-602

LNK/ACT

10/100100

Reset

852-0602

RS23

2 CO

NSO

LE

852 0

1

3

5

7

2

4

6

8

ALMPWR

RPS

POST

TX ports 10/100 Mbit/s

RS-232 port (RJ-45)

Page 85: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

83Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Industrial Managed Switch; 8 Ports 100Base-TX;2 Slots 1000BASE-SX/LX; PROFINET; Extended Temperature Range

Item Description Industrial Managed Switch; 8 Ports 100BASE-TX; 2 Slots 1000BASE-SX/LX; PROFINET; Extended Temperature Range

Item No. 852-603Order Text Industrial Managed Switch; 8Port 100BASE-TX; 2Slot 1000BASE-SX/LX; PROFINET; T

Technical DataSwitching mode Store‐and‐forward (non-blocking)Number of copper ports 8 x 10/100Base-TXNumber of FOC ports 2 x SFP slots, each configurable (100BASE-FX or 1000BASE-SX/LX)Communication standards IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TX/FXIEEE 802.3z 1000BASE-SX/LX

IEEE 802.3x Flow ControlIEEE 802.1d Spanning Tree Protocol (STP)

IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)

IEEE 802.1Q VLAN TaggingIEEE 802.1p Class of Service

IEEE 802.1ab Link Layer Discovery Protocol (LLDP)PROFINET Conformance Class B

Redundancy functions Redundant DC power supply; STP; RSTP; MSTP; Media redundancy protocol as manager or client

Configuration DIP switch for signal contact; Web-Based-Management; Command Line Interface; SNMPv1/v2/v3Diagnostics Signal contact; Port status; Port statistics; Port load; Traffic monitor; SFP information;

Syslog; SNMP traps; PN diagnostics (cyclic and acyclic)MAC table (large) 16000 addressesJumbo frame size 10 KBSupply voltage 12 ... 60 VDCPower consumption (max.) 12 WESD (contact/air discharge) 8 kV / 15 kVConnection technology (communication) 8 x RJ-45; 2 x SFP; 1 x RJ-45 (RS-232)Surrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 50 x 162 x 122 mm

Approvals 1; r OrdLocData sheet and additional information, see: wago.com/852-603

LNK/ACT

10/100

9

100

10

Reset

852-0603

RS23

2 CO

NSO

LE

852 0

1

3

5

7

2

4

6

8

9

ALM

LNK/A

CT

1000OFF

LINE

PWR

RPS

10

POST

LASE

R ON

TX ports 10/100 Mbit/s

1000BASE-SX/LX, LC, fiber optic (SFP type)

RS-232 port (RJ-45)

Page 86: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

84 Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Industrial Managed Switch; 8 Ports 1000BASE-T;4 Slots 1000BASE-SX/LX; PROFINET; Extended Temperature Range

Item Description Industrial Managed Switch; 8 Ports 1000BASE-T; 4 Slots 1000BASE-SX/LX; PROFINET; Extended Temperature Range

Item No. 852-1605Order Text Industrial Managed Switch; 8Port 1000BASE-T; 4Slot 1000BASE-SX/LX; PROFINET; T

Technical DataSwitching mode Store‐and‐forward (non-blocking)Number of copper ports 8 x 10/100/1000BASE-TNumber of FOC ports 4 x 1000Base-SX/LXCommunication standards IEEE 802.3 10BASE-T

IEEE 802.3u 100BASE-TXIEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-SX/LXIEEE 802.3x Flow Control

IEEE 802.1d Spanning Tree Protocol (STP)IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)

IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)IEEE 802.1Q VLAN Tagging

IEEE 802.1p Class of ServiceIEEE 802.1ab Link Layer Discovery Protocol (LLDP)

PROFINET Conformance Class BRedundancy functions Redundant DC power supply; STP; RSTP; MSTP;

Media redundancy protocol as manager or clientConfiguration DIP switch for signal contact; Web-Based-Management; Command Line Interface; SNMPv1/v2/v3Diagnostics Signal contact; Port status; Port statistics; Port load; Traffic monitor; SFP information;

Syslog; SNMP traps; PN diagnostics (cyclic and acyclic)MAC table (large) 16000 addressesJumbo frame size 10 KBSupply voltage 12 ... 60 VDCPower consumption (max.) 12 WESD (contact/air discharge) 8 kV / 15 kVConnection technology (communication) 8 x RJ-45; 4 x SFP; 1 x RJ-45 (RS-232)Surrounding air temperature (operation) −40 … +70 °CDimensions W x H x D 50 x 162 x 120 mm

Approvals 1; r OrdLocData sheet and additional information, see: wago.com/852-1605

11

ALMPWR

RPS

9 10 1211

12

9 10

1

3

5

7

2

4

6

8

1000M

10/100M

SFP

POST

852-1605

RS23

2 CO

NSO

LE

852 1

Rese

t

T-ports 1000 Mbit/s

1000BASE-SX/LX, LC, fiber optic (SFP type)

RS-232 port (RJ-45)

Page 87: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

85Supplementary Catalog – Automation Technology

Volume 3, Section 7 | Industrial Switches

Page 88: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

86 Supplementary Catalog – Automation Technology

Volume 3, Section 8 | Radio Technology

WLAN ETHERNET Gateway

Item Description Wireless ETHERNET Gateway; External antenna The Wireless ETHERNET Gateway simplifies the creation of a wireless transmission link for ETHERNET protocols (e.g., PROFINET, Modbus/TCP, EtherNet/IPTM).The gateway is used as a cable substitute to create a robust, industry-proven Bluetooth® or WLAN link between two automation devices. The gateway supports various configurations and can therefore also be operated as an access point.IP65 protection type and an external antenna al-low installation of the Wireless ETHERNET Gate-way within a conductive housing. The external antenna must be mounted on the outside of the housing. Simple push-button operation rapidly connects two Wireless ETHERNET Gateways.Additional settings can be made via Web-Based Management.

Note:Two Wireless ETHERNET Gateways of the same type are required to establish a peer-to-peer connection.

Item No. 758-918/000-001Order Text Wireless ETHERNET Gateway; External Antenna

Technical DataRadio technology Bluetooth®: 4.0;

WLAN: 802.11a/b/g/d/e/i/hTopology Peer-to-peer connectionSecurity authentication WLAN: WPA/WPA2 PSK; LEAP; PEAPSecurity encryption WLAN: none; WEP64; WEP128; TKIP; AES/CCMPFrequency band ISM band; 2.4 GHz (Bluetooth®, WLAN);

ISM band; 5 GHz (WLAN)Transmission range Up to 400 m*Antenna External dipole antenna (3dBi);

included in deliverySupply voltage 24 VDC (9 … 30 V)Connectors ETHERNET connector:

M12 socket, D-codedPower connector:

M12 plug, A-coded; RP-SMA socket for external antenna

Configuration Simple push-button operation and Web-Based Management

Number of inputs 1 (trigger input: 9 … 30 VDC)Surrounding air temperature (operation) −30 … +65 °CDimensions W x H x D 67.8 × 33.2 x 92.7Protection type IP65

Approvals 1Data sheet and further information, see: wago.com/758-918/000-001

*The maximum range in the field decreases within buildings and varies depending on build-ing materials and spatial geometry. Therefore, range specifications within buildings can only represent a typical value that can normally be achieved. More detailed information is available in the manual.

1: Vin + (9 … 30 VDC)2: Digital input GND3: Vin GND (0 V)4: Digital input + (9 … 30 VDC)5: Functional ground

1: Transmit +2: Receive +3: Transmit -4: Receive -

ETHERNET connector:M12 socket, D-coded

Power connector:M12 plug, A-coded

Page 89: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

87Supplementary Catalog – Automation Technology

Volume 3, Section 10 | Accessories and Tools

Item Description microSD Memory Card; Temperature range: −40 … +90 °C

SD Memory Card; Temperature range: −40 … +90 °C

Version pSLC-NAND; 8 GB pSLC-NAND; 8 GBItem No. 758-879/000-3108 758-879/000-2108

Technical DataMemory 8 GB (pSLC) 8 GB (pSLC)Read/write cycles (max.) 48 MB/s / 45 MB/s 50 MB/s / 45 MB/sMTBF 2,000,000 h 2,000,000 hService life 20.000 write cycles (per cell) 20.000 write cycles (per cell)Data storage 10 years 10 yearsSurrounding air temperature (operation) −40 … +90 °C −40 … +90 °C Surrounding air temperature (storage) −40 … +90 °C −40 … +90 °C Relative humidity 95 %, non-condensing 95 %, non-condensingDimensions W x H x D 15 x 11 x 1 mm 24 x 32 x 2.1 mmVibration resistance 15g 15g Shock resistance 50g 50g

Memory Cards

Page 90: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

88 Supplementary Catalog – Automation Technology

Volume 3, Section 10 | Accessories and Tools

Accessories

Room Control UnitItem No. Pack. Unit

WRF04-P Room Control Unit, Passive, Surface-mount, Pt1000, 5 kOhm 2852-7110 1WRF07-P Room Control Unit, Passive, Flush-mount, Pt1000, 5 kOhm 2852-7111 1SR04-P Room Control Unit, Radio, Surface-mount, EnOcean 2852-7112 1SR06-LCD Room Control Unit, Radio, Flush-mount, EnOcean, 2 push buttons

2852-7113 1

WRF04-P-RS-485 Room Control Unit, MODBUS, Surface-mount, Temperature, Set point value

2852-7114 1

WRF07-P-RS-485 Room Control Unit, MODBUS, Flush-mount, Temperature, Set point value

2852-7115 1

Manual Operation ModuleItem No. Pack. Unit

RBT10 Signaling Module, 12 LEDs 2852-7510 1RBT20 Output Module, 4 switches, 8 LEDs 2852-7511 1RBT30 Output Module, 4 push-buttons, 4 LEDs + 12 LEDs 2852-7512 1RBT40 Analog Module, 4 rotary encoders, 4 bar displays 2852-7513 1RBT50 Operating Module, 2 analog, 2 digital 2852-7514 1

Connection BoardItem No. Pack. Unit

RBT-AK Connection Board for Robutec Series 2852-7515 1

RackItem No. Pack. Unit

RTR4050S Rack 4 HE, 50TE 2852-7516 1

Figure: 2852-7110

Figure: 2852-7510

Page 91: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

89Supplementary Catalog – Automation Technology

Volume 3, Section 10 | Accessories and Tools

Accessories

DALI SensorsItem No. Pack. Unit

DALI Sensor; PD11-BMS-FLAT 2852-7210 1DALI Sensor; PD4-BMS-GH 2852-7213 1DALI Sensor; PD4N-BMS 2852-7214 1Adapter; AP assembly kit IP54; Accessories for 2852-7214 2852-7215 1DALI Sensor; MSensor G3 SRC 30 PIR 5DPI WH 2852-7220 1DALI Sensor; IR Quattro HD DALI-2 2852-7230 1DALI Sensor; IR Quattro SLIM XS DALI-2 2852-7231 1DALI Sensor; IS3360 MX HIGH BAY DALI-2 2852-7232 1DALI Sensor; IS345 MX HIGH BAY DALI-2 2852-7233 1

Room Control UnitsItem No. Pack. Unit

Room Control Unit; Modbus®; RBG1; Display; Glass front; Aluminum frame; black

2852-7601/000-001 1

Room Control Unit; Modbus®; RBG1; Display; Glass front; Aluminum frame; white

2852-7601/000-002 1

Figure: 2852-7601/000-001

Figure: 2852-7214

Page 92: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

Volume 4, WAGO Electronic Interface

Page 93: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4 | WAGO Electronic Interface

Volume 4, WAGO Electronic Interface

Page1-Phase Power Measurement Module; Digital Output; Configuration via Software 92Energy Meter with Push-in CAGE CLAMP® and Lever 94

Split-Core Current Transformer 100

Power Supply; Pro 2; 1-Phase; 24 VDC / 5 A 104Power Supply; Pro 2; 1-Phase; 24 VDC / 10 A 105Power Supply; Pro 2; 1-Phase; 24 VDC / 20 A 106Power Supply; Pro 2; 1-Phase; 24 VDC / 40 A 107Power Supply; Pro 2; 1-Phase; 48 VDC / 10 A 108Power Supply; Pro 2; 3-Phase; 24 VDC / 10 A 109Power Supply; Pro 2; 3-Phase; 24 VDC / 20 A 110Power Supply; Pro 2; 3-Phase; 24 VDC / 40 A 111Modbus RTU Communication Module; for Pro 2 Power Supplies 112IO-Link Communication Module; for Pro 2 Power Supplies 113

Power Supply; Compact; 1-Phase; 12 VDC / 2.5 … 8 A 114Power Supply; Compact; 1-Phase; 24 VDC / 1.25 A 116

Pure Lead Battery Module; 24 VDC / 20 … 40 A 117

Redundancy Module; 24 VDC / 25 … 76 A; Ex Approval 119

Electronic Circuit Breaker; 1 Channel; 24 VDC / 0.5 A 121Electronic Circuit Breaker; 4 Channels; 24 VDC / 1 … 10 A; NPN Signaling 122

Ground Resistance Signaling Module 124Volume 4, WAGO Electronic InterfaceProducts highlighted in RED are new items for Spring 2020.

91

Page 94: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

OUT-

OUT+

OUT-

OUT+

GND 2

US+

GND 2

4.4

4.3

4.2

4.1

5.2

5.1

6.2

6.1

5.4

5.3

1.4

1.3

1.2

1.1

14

11

12

N.C.

500 V

N (GND 1)

30 V

250 V

N (GND 1)

8 A

5 A

1 A

2.1

2.4

2.3

2.2

3.4

3.3

3.2

3.1 DO (GND 2)

GND 2

Supply

Voltage

Supply

Voltage

Voltage

IN

Current

IN US+

Relay

Output

Analog

Output

(AO)

Digital

Output

(DO)

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

1-Phase Power Measurement Module; Current and voltage input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC

Item No. Pack. Unit2857-569 1

Short description:WAGO’s 1-Phase Power Measurement Module monitors and reports signal states with up to two switching thresh-olds. The sensor and status information that is collected is also converted to a standard analog signal. Current, volt-age, effective power, apparent power or reactive power can be selected as the measured variable.Additionally, both frequency and phase angle are dis-played.Features:• A relay with changeover contact reacts to configured

measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values).

• Adjustable software filter• Simulation of input/output response via WAGO Interface

Configuration Display• Analog unipolar/bipolar signals (current/voltage) at out-

put• Additional digital signal output for configured measure-

ment range limits• The digital output can be configured as a frequency

generator or pulse output (S0 interface).

Note:Additional setting options via WAGO Interface Configura-tion Software or WAGO Configuration Display

1-Phase Power Measurement Module; Digital Output; Configuration via Software2857 Series

ConfigurationConfiguration options WAGO Interface Configuration Software;

WAGO Configuration Display

InputInput signal type Voltage; CurrentInput signal (voltage) 500 V AC/DC (IN 2.1; per EN 61010-1);

300 V AC/DC (IN 2.1; per UL 61010-1); 250 V AC/DC (IN 2.2) ; 30 V AC/DC (IN 2.3)

Input signal (current) 1 A AC/DC (IN 3.1); 5 A AC/DC (IN 3. 2); 8 A AC/DC (IN 3. 3)

Frequency range 15 … 400 Hz (AC)Input voltage (max.) 1.2 × UN

Input current (max.) 1.2 × IN (≤ 60 °C); 1 × IN (60 … 70 °C)Response threshold (voltage) 500 mVAC / 600 mVDC (IN 2.1);

50 mVAC / 500 mVDC (IN 2.2); 20 mVAC / 100 mVDC (IN 2.3)

Response threshold (current) 1.5 mAAC / 7.5 mADC (IN 3.1); 3 mAAC / 10 mADC (IN 3.2); 7.5 mAAC / 12 mADC (IN 3.3)

Resolution (voltage) 50 mV (IN 2.1); 30 mV (IN 2.2); 5 mV (IN 2.3)Resolution (current) 1 mA (for all measurement ranges)

Output – AnalogOutput signal type Current; VoltageOutput signal (voltage) ±12 V (SELV)Output signal (current) ±24 mA (SELV)Load impedance (voltage output) ≥ 2 kΩLoad impedance (current output) ≤ 600 Ω

Output – DigitalSwitching voltage (DO) (max.) Supply voltage (applied) – 0.3 VContinuous current (DO) (max.) 100 mA (no internal restriction)Number of switching thresholds (DO) 2 (max.)Configurable rise/fall delay time (DO) 0 … 60 s (via software)Configurable functions (DO) Inactive; US/GND switching; Threshold value switch;

Frequency generator; Pulse output (S0 interface)Setting range (frequency generator) 0.3 … 100 HzSetting range (pulse output) 1 … 1000 pulses/kWh

Output – RelaysNumber of changeover/switchover contacts 1Switching voltage (max.) 250 VACLimiting continuous current (relay; module assembly) 6 A (≤ 60 °C); 3 A (60 … 70 °C)Dielectric strength, open contact (AC, 1 min) 1 kVrms

Number of switching thresholds (relay) 1 or 2 (adjustable)Configurable rise/fall delay time (relay) 0 … 60 s (via software)

Signal ProcessingMeasurement method True RMS measurement (TRMS)Measured variables (calculated) Effective power; Apparent power; Reactive power;

Phase angle; FrequencyLimit frequency 2 kHzSoftware filter (adjustable) Adjustable: 1 … 30Step response (max.) ≤ 350 ms (default settings)

Measurement ErrorTransmission error (max.) ≤ 0.5 % for current and voltage (of the full scale value)

Power SupplyNominal supply voltage US 24 VDC (SELV)Supply voltage range -30 … +30 %Power consumption at nominal supply voltage ≤ 70 mA (+ IDO)

92

Page 95: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

22,5 mm/0.89 inch

10

7 m

m/4

.21

in

ch

110 mm/4.33 inch

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Specialty Functions:

Configuration via:

Safety and ProtectionTest voltage

Test voltage (input IN 2.1/relay output; per EN 61010-1)

5.4 kVAC; 50 Hz; 5 s / 3.6 kVAC; 50 Hz; 1 min

Test voltage (input IN 2.1/relay output; per UL 61010-1)

3.51 kVAC; 60 Hz; 1 min

Test voltage (input/supply and analog output/relay output)

3.51 kVAC; 50 … 60 Hz; 1 min

Test voltage (supply/analog output) 3.6 kVAC; 50 … 60 Hz; 1 minMeasurement category per EN/UL 61010-2-030 Cat. III (input)Insulation parameters per EN/UL 61010-1

External/Neutral conductor voltage 300 VACOvervoltage category IIIPollution degree 2Insulation type (input/supply and analog output/relay output)

Reinforced insulation

Insulation parameters per EN 61010-1

External/Neutral conductor voltage 600 VACOvervoltage category IIIPollution degree 2Insulation type (input IN 2.1/relay output) Reinforced insulationInsulation type (input/supply and analog output/relay output)

Double insulation (impedance and basic insulation) Requirement: The N (GND 1) input is dangerous when active!

Insulation type (supply/analog output) Basic insulationNote on insulation parameters The digital output (DO) is at the potential of the supply.

The service interface is located on the analog output potential.

Protection class IP20

Connection DataConnection technology Push-in CAGE CLAMP®WAGO Connector picoMAX® 5.0Solid conductor 0.2 … 2.5 mm² / 24 … 12 AWGFine-stranded conductor 0.2 … 2.5 mm² / 24 … 12 AWGStrip length 9 … 10 mm / 0.35 … 0.39 inch

Physical DataWidth 22.5 mm / 0.886 inchHeight from upper-edge of DIN-rail 107 mm / 4.213 inchDepth 110 mm / 4.331 inch

Mechanical DataMounting type DIN-35 rail

Material DataWeight 149 g

Environmental RequirementsSurrounding air temperature (operation) −40 … +70 °CSurrounding air temperature (storage) −40 … +85 °CTemperature range of connecting cable per EN 61010-2-201

≥ (Tsurrounding air + 25 K)

Temperature range of connecting cable per UL 61010-2-201

≥ 95 °C

Relative humidity 5 … 85 % (non-condensing)Operating altitude (max.) 2000 m

Standards and SpecificationsConformity marking CEEMC immunity to interference EN 61000-6-2; EN 61326-2-3EMC emission of interference EN 61000-6-3; EN 61326-2-3Standards/Specifications EN 61010-1; UL 61010-1; UL 61010-2-201

93

Page 96: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

45 m

m

72 mm 63 mm

48 mm

92 m

m

140

mm

Tariff 230 V~

Tariff 230 V~

N

L3

L3

L2

+ (M-bus)

A (RS485)SO2GNDSO1

B/- (RS485)

L2

L1

L1

987654

11

10

OUT

IN

OUT

IN

OUT

IN

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Energy Meter; with Push-in CAGE CLAMP® and Lever; Direct Connection (4PU)

Item No. Pack. Unit879-3000 1

Short description:Comprehensive energy measurement is necessary for op-timizing energy consumption. WAGO now has new energy meters in its portfolio that simplify this task while providing several key advantages. They use the push-in connection technology with a lever, making them connect quickly and easily. The devices have a width of just 72 mm for direct measurement. These widths save a tremendous amount of control cabinet space. In addition to the values for ac-tive and reactive energy, the energy meters also record the mains frequency as well as current, voltage and power for all phases. And the user can conveniently see all of these energy characteristics at a glance on a large, illumi-nated display.

Features:• Saving time at every level thanks to the Push-in CAGE

CLAMP® and lever • Real space savings: 72 mm wide (4PU)• The communications pro: M-Bus and

Modbus® interface and 2 S0 pulse outputs• Full transparency at a glance:

Display energy quality characteristics on an illuminated full-format display

• Intuitive configuration: Touch-sensitive controls and configuration app via Bluetooth®

Energy Meter (MID); with Push-in CAGE CLAMP® and Lever; Direct Connection (4PU)879 Series

ConfigurationConfiguration options Touch-sensitive controls;

Configuration app via Bluetooth®

InputInput voltage range 3 x 230 … 400 VAC; ±20 % Reference current Iref 5 AInput current 65 AFrequency range 45 … 65 HzNetwork configuration Two-wire, three-wire and four-wire networksPower consumption Pmax. ≤ 2 W/phase; ≤ 10 VA/phaseMeasured variable Active and reactive energy in supply and reference

direction

CommunicationCommunication Modbus®; M-Bus; Bluetooth®Interface RS-485 (2-wire); 2x S0 interfaces (configurable)Rate control input 230 VAC/VDCIndicators LCD with backlight

Measurement ErrorAccuracy class Class B (= 1 % error); Active energy per EN 50470-3Calibration validity period 8 years

Power SupplyPower supply type Via measurement circuit

Safety and ProtectionDielectric strength 4 kV, 1 min; 1.2/50 µs at 6 kVProtection class IP51 (front side); IP20 (connection)Protection class IIPollution degree 2

Connection DataConnection type (1) Voltage/Current

Connection technology Push-in CAGE CLAMP®Actuation type LeverWAGO Connector 2616 SeriesSolid conductor 0.75 … 16 mm² / 18 … 4 AWGFine-stranded conductor 0.75 … 25 mm² / 18 … 4 AWGFine-stranded conductor; with insulated ferrule 0.75 … 16 mm²Fine-stranded conductor; with uninsulated ferrule 0.75 … 16 mm²Fine-stranded conductor; with twin ferrule 0.75 … 6 mm²Strip length 18 … 20 mm / 0.71 … 0.79 inch

Connection type 2 Communication and rate control inputConnection technology 2 Push-in CAGE CLAMP®Actuation type 2 LeverWAGO Connector 2 2604 SeriesSolid conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor; with insulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with uninsulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with twin ferrule 2 0.25 … 1.5 mm²Strip length 2 9 … 11 mm / 0.35 … 0.43 inch

Physical DataWidth 72 mmHeight 140 mmDepth 63 mmNote (dimensions) Height without cover: 92 mm

Mechanical DataMounting type DIN-35 rail (EN 60715)

Material DataHousing material PC 940A

Environmental RequirementsSurrounding air temperature (operation) –40 … +70 °C

94

Page 97: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Relative humidity ≤ 75 % (during storage ≤ 95 %)

Standards and SpecificationsConformity marking 1Standards/Specifications EN 50470-1/3;

MID-compliant

95

Page 98: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

N

L3

L2

L1

L3

L2

L1

OUT IN

OUT

OUT

IN

IN

+ (M-bus)

A (RS485)SO2GNDSO1

B/- (RS485)987654

Tariff 230 V~

Tariff 230 V~

11

10

45 m

m

72 mm 63 mm

48 mm

92 m

m

140

mm

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Energy Meter; with Push-in CAGE CLAMP® and Lever; Direct Connection (4PS)

Item No. Pack. Unit879-3020 1

Energy Meter (MID); with Push-in CAGE CLAMP® and Lever; Direct Connection (4PS)879 Series

ConfigurationConfiguration options Touch-sensitive controls;

Configuration app via Bluetooth®

InputInput voltage range 3 x 230 … 400 VAC; ±20 % Reference current Iref 5 AInput current 65 AFrequency range 45 … 65 HzNetwork configuration Two-wire, three-wire and four-wire networksPower consumption Pmax. ≤ 2 W/phase; ≤ 10 VA/phaseMeasured variable Active and reactive energy in supply and reference

direction

CommunicationCommunication Modbus®; M-Bus; Bluetooth®Interface RS-485 (2-wire); 2x S0 interfaces (configurable)Rate control input 230 VAC/VDCIndicators LCD with backlight

Measurement ErrorAccuracy class Class B (= 1 % error); Active energy per EN 50470-3Calibration validity period 8 years

Power SupplyPower supply type Via measurement circuit

Safety and ProtectionDielectric strength 4 kV, 1 min; 1.2/50 µs at 6 kVProtection class IP51 (front side); IP20 (connection)Protection class IIPollution degree 2

Connection DataConnection type (1) Voltage/Current

Connection technology Push-in CAGE CLAMP®Actuation type LeverWAGO Connector 2616 SeriesSolid conductor 0.75 … 16 mm² / 18 … 4 AWGFine-stranded conductor 0.75 … 25 mm² / 18 … 4 AWGFine-stranded conductor; with insulated ferrule 0.75 … 16 mm²Fine-stranded conductor; with uninsulated ferrule 0.75 … 16 mm²Fine-stranded conductor; with twin ferrule 0.75 … 6 mm²Strip length 18 … 20 mm / 0.71 … 0.79 inch

Connection type 2 Communication and rate control inputConnection technology 2 Push-in CAGE CLAMP®Actuation type 2 LeverWAGO Connector 2 2604 SeriesSolid conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor; with insulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with uninsulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with twin ferrule 2 0.25 … 1.5 mm²Strip length 2 9 … 11 mm / 0.35 … 0.43 inch

Physical DataWidth 72 mmHeight 140 mmDepth 63 mmNote (dimensions) Height without cover: 92 mm

Mechanical DataMounting type DIN-35 rail (EN 60715)

Material DataHousing material PC 940A

Environmental RequirementsSurrounding air temperature (operation) –40 … +70 °C

Short description:Comprehensive energy measurement is necessary for op-timizing energy consumption. WAGO now has new energy meters in its portfolio that simplify this task while providing several key advantages. They use the push-in connection technology with a lever, making them connect quickly and easily. The devices have a width of just 72 mm for direct measurement. These widths save a tremendous amount of control cabinet space. In addition to the values for ac-tive and reactive energy, the energy meters also record the mains frequency as well as current, voltage and power for all phases. And the user can conveniently see all of these energy characteristics at a glance on a large, illumi-nated display.

Features:• Saving time at every level thanks to the Push-in CAGE

CLAMP® and lever • Real space savings: 72 mm wide (4PS)• The communications pro: M-Bus and

Modbus® interface and 2 S0 pulse outputs• Full transparency at a glance:

Display energy quality characteristics on an illuminated full-format display

• Intuitive configuration: Touch-sensitive controls and configuration app via Bluetooth®

96

Page 99: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Relative humidity ≤ 75 % (during storage ≤ 95 %)

Standards and SpecificationsConformity marking 1Standards/Specifications EN 50470-1/3;

MID-compliant

97

Page 100: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

N

U3

U2

U1

SO2

GND

SO1

CT3

CT3

CT2

CT2

CT1

CT1

OUT

IN

OUT

IN

OUT

IN

Tariff 230 V~

Tariff 230 V~

9

8

7

6

5

4

11

10

+ (M-bus)

A (RS485)

B/- (RS485)

45 m

m

36 mm 63 mm

48 mm

97 m

m

140

mm

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Energy Meter; with Push-in CAGE CLAMP® and Lever; Transformer Connection (2PCT)

Item No. Pack. Unit879-3040 1

Energy Meter (MID); with Push-in CAGE CLAMP® and Lever; Transformer Connection (2PCT)879 Series

ConfigurationConfiguration options Touch-sensitive controls; Configuration app via Blue-

tooth®

InputInput voltage range 3 x 230 … 400 VAC; ±20 % Reference current Iref 1 AInput current 6 ACurrent transformer (secondary) 1 A / 5 ACurrent transformer ratio 1 … 10,000Frequency range 45 … 65 HzNetwork configuration Two-wire, three-wire and four-wire networksPower consumption Pmax. ≤ 2 W/phase; ≤ 10 VA/phaseMeasured variable Active and reactive energy in supply and reference

direction

CommunicationCommunication Modbus®; M-Bus; Bluetooth®Interface RS-485 (2-wire); 2x S0 interfaces (configurable)Rate control input 230 VAC/VDCIndicators LCD with backlight

Measurement ErrorAccuracy class Class B (= 1 % error); Active energy per EN 50470-3Calibration validity period 8 years

Power SupplyPower supply type Via measurement circuit

Safety and ProtectionDielectric strength 4 kV, 1 min; 1.2/50 µs at 6 kVProtection class IP51 (front side); IP20 (connection)Protection class IIPollution degree 2

Connection DataConnection type (1) Voltage/Current

Connection technology Push-in CAGE CLAMP®Actuation type LeverWAGO Connector 2604 SeriesSolid conductor 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor; with insulated ferrule 0.25 … 2.5 mm²Fine-stranded conductor; with uninsulated ferrule 0.25 … 2.5 mm²Fine-stranded conductor; with twin ferrule 0.25 … 1.5 mm²Strip length 9 … 11 mm / 0.35 … 0.43 inch

Connection type 2 Communication and rate control inputConnection technology 2 Push-in CAGE CLAMP®Actuation type 2 LeverWAGO Connector 2 2604 SeriesSolid conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor 2 0.2 … 4 mm² / 24 … 12 AWGFine-stranded conductor; with insulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with uninsulated ferrule 2 0.25 … 2.5 mm²Fine-stranded conductor; with twin ferrule 2 0.25 … 1.5 mm²Strip length 2 9 … 11 mm / 0.35 … 0.43 inch

Physical DataWidth 36 mmHeight 140 mmDepth 63 mmNote (dimensions) Height without cover: 98.2 mm

Mechanical DataMounting type DIN-35 rail (EN 60715)

Material DataHousing material PC 940A

Environmental RequirementsSurrounding air temperature (operation) –40 … +70 °C

Short description:Comprehensive energy measurement is necessary for op-timizing energy consumption. WAGO now has new energy meters in its portfolio that simplify this task while providing several key advantages. They use the push-in connection technology with a lever, making them connect quickly and easily. Versions for current transformers are even slimmer at only 35 mm. These widths save a tremendous amount of control cabinet space. In addition to the values for ac-tive and reactive energy, the energy meters also record the mains frequency as well as current, voltage and power for all phases. And the user can conveniently see all of these energy characteristics at a glance on a large, illumi-nated display.

Features:• Saving time at every level thanks to the Push-in CAGE

CLAMP® and lever • Real space savings: 35 mm wide (2PCT)• The communications pro: M-Bus and

Modbus® interface and 2 S0 pulse outputs• Full transparency at a glance:

Display energy quality characteristics on an illuminated full-format display

• Intuitive configuration: Touch-sensitive controls and configuration app via Bluetooth®

98

Page 101: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 3 | WAGO Signal Conditioners

Relative humidity ≤ 75 % (during storage ≤ 95 %)

Standards and SpecificationsConformity marking 1Standards/Specifications EN 50470-1/3;

MID-compliant

99

Page 102: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 4 | WAGO Current and Energy Measurement Technology

Short description:The compact WAGO Split-Core Current Transformers are ideal for retrofitting existing systems. They are perfect for applications in which the current path must not be disrupt-ed. The transformer’s accuracy permits extremely precise current measurements. WAGO’s Split-Core Current Trans-formers are capable of supplying the specified rated pow-er at the end of the secondary cable. All transformers are supplied with color-coded cables. Two UV-resistant cable ties are also included for secure and easy mounting.

Features:• Current ratios from 75 A up to 800 A (primary side) and 1

A or 5 A (secondary side)• No primary cable interruption• Ideal for use in very confined spaces• Rapid mounting• For use around insulated cables up to 42 mm diameter• Compact and hinged• Color-coded connection cables up to 5 m

Note:Additional variants, visit www.wago.com

Split-Core Current Transformer855 Series

Input – Current TransformersRated continuous thermal current Icth 100 %Rated short-time thermal current Ith 60 x IN/1 sRated surge current Idyn 2.5 x Ith

Rated frequency 50 … 60 Hz

Safety and ProtectionTest voltage 3 kVAC; 50 Hz; 1 minProtection class IP20Highest voltage for equipment Um 720 VAC

Mechanical DataMounting type Split-core current transformer

Material DataInsulation class EFlammability class per UL94 V2Housing material PA 66

Environmental RequirementsSurrounding air temperature (operation) −10 … +55 °CSurrounding air temperature (storage) −20 … +70 °CRelative humidity 5 … 85 % (no condensation)Operating altitude (max.) 2000 m

Standards and SpecificationsConformity marking CEStandards/Specifications EN 61869-1; EN 61869-2

100

Page 103: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 4 | WAGO Current and Energy Measurement Technology

Split-Core Current Transformer; Primary cable feedthrough: 18 mm Ø

Prim. Rated Current

Sec. Rated Current Rated Power Accuracy

ClassCable Length

Conductor Cross-Sec-tion

Item No. Pack. Unit

125 A 1 A 0.2 VA 1 3 m 0.5 mm² 855-4001/125-001 1

200 A 5 A 1 VA 1 0.5 m 1.5 mm² 855-4005/200-101 1

250 A 1 A 0.2 VA 0,5 3 m 0.5 mm² 855-4001/250-000 1

250 A 5 A 1 VA 0,5 0.5 m 1.5 mm² 855-4005/250-100 1

Split-Core Current Transformer855 Series

Split-Core Current Transformer; Primary cable feedthrough: 18 mm Ø

Prim. Rated Current

Sec. Rated Current Rated Power Accuracy

ClassCable Length

Conductor Cross-Sec-tion

Item No. Pack. Unit

75 A 1 A 0.2 VA 3 3 m 0.5 mm² 855-3001/075-003 1

125 A 1 A 0.2 VA 3 3 m 0.5 mm² 855-3001/125-003 1

150 A 1 A 0.2 VA 3 3 m 0.5 mm² 855-3001/150-003 1

Split-Core Current Transformer; Primary cable feedthrough: 28 mm Ø

Prim. Rated Current

Sec. Rated Current Rated Power Accuracy

ClassCable Length

Conductor Cross-Sec-tion

Item No. Pack. Unit

300 A 1 A 0.2 VA 1 3 m 0.5 mm² 855-4101/300-001 1

300 A 5 A 1 VA 1 0.5 m 1.5 mm² 855-4105/300-101 1

500 A 1 A 0.2 VA 0,5 3 m 0.5 mm² 855-4101/500-000 1

500 A 5 A 1 VA 1 0.5 m 1.5 mm² 855-4105/500-101 1

101

Page 104: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 4 | WAGO Current and Energy Measurement Technology

Split-Core Current Transformer; Primary cable feedthrough: 42 mm Ø

Prim. Rated Current

Sec. Rated Current Rated Power Accuracy

ClassCable Length

Conductor Cross-Sec-tion

Item No. Pack. Unit

300 A 1 A 0.5 VA 1 5 m 0.5 mm² 855-5001/300-001 1

300 A 5 A 0.5 VA 1 3 m 1.5 mm² 855-5005/300-001 1

500 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5001/500-000 1

500 A 5 A 0.5 VA 1 3 m 1.5 mm² 855-5005/500-001 1

750 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5001/750-000 1

750 A 5 A 0.5 VA 0,5 3 m 1.5 mm² 855-5005/750-000 1

800 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5001/800-000 1

800 A 5 A 0.5 VA 0,5 3 m 1.5 mm² 855-5005/800-000 1

Split-Core Current Transformer; Primary cable feedthrough: 2 x Ø 42 mm

Prim. Rated Current

Sec. Rated Current Rated Power Accuracy

ClassCable Length

Conductor Cross-Sec-tion

Item No. Pack. Unit

250 A 1 A 0.5 VA 1 5 m 0.5 mm² 855-5101/250-001 1

300 A 1 A 0.5 VA 1 5 m 0.5 mm² 855-5101/300-001 1

300 A 5 A 0.5 VA 1 3 m 1.5 mm² 855-5105/300-001 1

400 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5101/400-000 1

400 A 5 A 0.5 VA 1 3 m 1.5 mm² 855-5105/400-001 1

500 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5101/500-000 1

500 A 5 A 0.5 VA 1 3 m 1.5 mm² 855-5105/500-001 1

600 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5101/600-000 1

600 A 5 A 0.5 VA 0,5 3 m 1.5 mm² 855-5105/600-000 1

750 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5101/750-000 1

750 A 5 A 0.5 VA 0,5 3 m 1.5 mm² 855-5105/750-000 1

800 A 1 A 0.5 VA 0,5 5 m 0.5 mm² 855-5101/800-000 1

800 A 5 A 0.5 VA 0,5 3 m 1.5 mm² 855-5105/800-000 1

Split-Core Current Transformer855 Series

102

Page 105: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 4 | WAGO Current and Energy Measurement Technology

103

Page 106: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3N

L

DI− DI+ DO− DO+

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 1-phase; Output voltage: 24 VDC; Output current: 5 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2144 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 1-Phase; 24 VDC / 5 A2787 Series

InputNominal input voltage Ui nom 100 … 240 VACInput voltage range 90 … 264 VAC; 130 … 373 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii 1.8 … 1 A (nominal load)Inrush current ≤ 9 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 20 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 5 A (24 VDC)Nominal output power 120 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 1 W (stand-by); ≤ 2 W (no load); ≤ 10 W (nominal load)Efficiency (typ.) 93.8 % (230 VAC; 5 A; 25 °C)

Fuse ProtectionInternal fuse T 6.3 A / 250 VACRecommended backup fusing 16 A (for USA/Canada: 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 1,000,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating See instruction leafletPollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 35 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 166 mm

Mounting type DIN-35 rail (EN 60715)Weight 650 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

104

Page 107: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3N

L

DI− DI+ DO− DO+

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 1-phase; Output voltage: 24 VDC; Output current: 10 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2146 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 1-Phase; 24 VDC / 10 A2787 Series

InputNominal input voltage Ui nom 100 … 240 VACInput voltage range 90 … 264 VAC; 130 … 373 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii 2.7 … 1.2 A (nominal load)Inrush current ≤ 11 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 25 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 10 A (24 VDC)Nominal output power 240 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 1 W (stand-by); ≤ 2.2 W (no load);

≤ 12 W (nominal load / 230 VAC)Efficiency (typ.) 95.3 % (230 VAC; 10 A; 25 °C)

Fuse ProtectionInternal fuse T 6.3 A / 250 VACRecommended backup fusing 16 A (for USA/Canada: 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 1,200,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating −3 %/K (> +55 °C and Ui < 230 VAC);

−3 %/K (> +60 °C and Ui ≥ 230 VAC)Pollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 50 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 166 mm

Mounting type DIN-35 rail (EN 60715)Weight 1000 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

105

Page 108: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3N

L

DI− DI+ DO− DO+

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 1-phase; Output voltage: 24 VDC; Output current: 20 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2147 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 1-Phase; 24 VDC / 20 A2787 Series

InputNominal input voltage Ui nom 100 … 240 VACInput voltage range 90 … 264 VAC; 130 … 373 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii 5.9 … 2.2 A (nominal load)Inrush current ≤ 12 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 24 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 20 A (24 VDC)Nominal output power 480 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 1.3 W (stand-by); ≤ 2.6 W (no load);

≤ 24 W (nominal load / 230 VAC)Efficiency (typ.) 95.4 % (230 VAC; 20 A; 25 °C)

Fuse ProtectionInternal fuse T 10 A / 250 VACRecommended backup fusing 16 A (for USA/Canada: 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 900,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating −1 %/V (> +40 °C and Ui < 100 VAC);

−3 %/K (> +55 °C and Ui < 230 VAC); −3 %/K (> +60 °C and Ui ≥ 230 VAC); −5 %/V (Uo > 24 VDC)

Pollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 70 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 1450 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

106

Page 109: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3N

L

DI− DI+ DO− DO+

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 1-phase; Output voltage: 24 VDC; Output current: 40 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2448 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 1-Phase; 24 VDC / 40 A2787 Series

InputNominal input voltage Ui nom 200 ... 240 VACInput voltage range 180 … 264 VAC; 255 … 373 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii 5.1 … 4.3 A (nominal load)Inrush current ≤ 10 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 25 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 40 A (24 VDC)Nominal output power 960 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 1.5 W (stand-by); ≤ 2.4 W (no load);

≤ 40 W (nominal load / 230 VAC)Efficiency (typ.) 96.1 % (230 VAC; 40 A; 25 °C);

96.3 % (230 VAC; 30 A; 25 °C)

Fuse ProtectionInternal fuse T 10 A / 250 VACRecommended backup fusing 16 A (for USA/Canada: 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 900,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating -3 %/K (> +55 °C)Pollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 120 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 1950 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

107

Page 110: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3N

L

DI− DI+ DO− DO+

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

2787 Series

Power Supply;Pro 2; 1-Phase; 48 VDC / 10 A

Power Supply; Pro 2; 1-phase; Output voltage: 48 VDC; Output current: 10 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2157 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

InputNominal input voltage Ui nom 100 … 240 VACInput voltage range 90 … 264 VAC; 130 … 373 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii 5.9 … 2.2 A (nominal load)Inrush current ≤ 12 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 24 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 48 VDC (SELV) / ≤ 1 %Output voltage range 48 … 56 VDC (adjustable)Nominal output current Io nom 10 A (48 VDC)Nominal output power 480 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 1.3 W (stand-by); ≤ 2.6 W (no load);

≤ 24 W (nominal load / 230 VAC)Efficiency (typ.) > 94 % (230 VAC; 20 A; 25 °C)

Fuse ProtectionInternal fuse T 10 A / 250 VACRecommended backup fusing 16 A (for USA/Canada: 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 900,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating −1 %/V (> +40 °C and Ui < 100 VAC);

−3 %/K (> +55 °C and Ui < 230 VAC); −3 %/K (> +60 °C and Ui ≥ 230 VAC); −5 %/V (Uo > 48 VDC)

Pollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 70 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 1450 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

108

Page 111: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3L3

L2

DI− DI+ DO− DO+

L1

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 3-phase; Output voltage: 24 VDC; Output current: 10 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2346 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 3-Phase; 24 VDC / 10 A2787 Series

InputNominal input voltage Ui nom (2/3) x 400 … 500 VACInput voltage range (2/3) x 340 … 550 VAC; 480 … 780 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii ≤ 3 x 0.6 A (400 VAC; 10 ADC)Inrush current ≤ 3 x 15 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 20 ms (3 x 400 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 20 A (24 VDC)Nominal output power 480 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 3 W (stand-by); ≤ 3 W (no load); ≤ 18 W (nominal load)Efficiency (typ.) > 93 % (400 VAC; 10 A; 25 °C)

Fuse ProtectionInternal fuse 3 x T 2.5 A / 500 VACRecommended backup fusing 3 x 16 A (for USA/Canada: 3 x 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 1,000,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating See instruction leafletPollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 50 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 1000 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

109

Page 112: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3L3

L2

DI− DI+ DO− DO+

L1

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 3-phase; Output voltage: 24 VDC; Output current: 20 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2347 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 3-Phase; 24 VDC / 20 A2787 Series

InputNominal input voltage Ui nom (2/3) x 400 … 500 VACInput voltage range (2/3) x 340 … 550 VAC; 480 … 780 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii ≤ 3 x 0.8 A (400 VAC; 20 ADC)Inrush current ≤ 3 x 15 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 20 ms (3 x 400 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 20 A (24 VDC)Nominal output power 480 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl ≤ 3.6 W (stand-by); ≤ 4.4 W (no load); ≤ 21 W (nominal

load)Efficiency (typ.) 95.9 % (400 VAC; 20 A; 25 °C)

Fuse ProtectionInternal fuse 3 x T 2.5 A / 500 VACRecommended backup fusing 3 x 16 A (for USA/Canada: 3 x 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 800,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating See instruction leafletPollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 70 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 1400 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

110

Page 113: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

+

+

3L3

L2

DI− DI+ DO− DO+

L1

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Pro 2; 3-phase; Output voltage: 24 VDC; Output current: 40 A; TopBoost + PowerBoost; DI/DO; Communication interface

Item No. Pack. Unit2787-2348 1

Features:• Power supply with TopBoost, PowerBoost and configu-

rable overload behavior• Configurable digital signal input and output, optical sta-

tus indication, function keys• Communication interface for configuration and monitor-

ing• Optional connection to IO-Link• Suitable for both parallel and series operation • Natural convection cooling when horizontally mounted• Pluggable connection technology• Electrically isolated output voltage (SELV/PELV) per

EN 61010/UL 61010• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Power Supply;Pro 2; 3-Phase; 24 VDC / 40 A2787 Series

InputNominal input voltage Ui nom (2/3) x 400 … 500 VACInput voltage range (2/3) x 340 … 550 VAC; 480 … 780 VDCNominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii ≤ 3 x 1.7 A (240 VAC; 40 ADC)Inrush current ≤ 3 x 15 A (after 1 ms)Power factor correction (PFC) ActiveMains failure hold-up time ≥ 20 ms (3 x 400 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 1 %Output voltage range 24 … 28 VDC (adjustable)Nominal output current Io nom 40 A (24 VDC)Nominal output power 960 WResidual ripple ≤ 70 mV (peak-to-peak)Overload behavior TopBoost/PowerBoost/Time-limited constant current

mode (other overload behaviors can be set)

Signaling and CommunicationSignaling Optical status indication (DC OK; load; warning and error

states); Digital signal input and output (DI/DO)Communication Communication interface, can be used with

WAGO USB Communication Cable (750-923) or IO-Link Communication Module (2789-9080) or Modbus RTU Communication Module (2789-9015)

Efficiency/Power LossesPower loss Pl See manualEfficiency (typ.) 96.3 % (400 VAC; 40 A; 25 °C)

Fuse ProtectionInternal fuse 3 x T 3.2 A / 500 VACRecommended backup fusing 3 x 16 A (for USA/Canada: 3 x 15 A)

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec-GND/sec.-DI/sec.-DO)

3.51 kVAC / 2.2 kVAC / 0.5 kVAC / 0.5 kVAC / 0.5 kVAC

Protection class/type I / IP20 (per EN 60529)Overvoltage category III (≤ 2000 m a. s.l.); II (> 2000 m a. s.l.)Short-circuit-protected YesParallel/series operation Yes/YesMTBF > 800,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °C (device starts at −40 °C, type-tested)Relative humidity 5 … 96 % (no condensation permissible)Derating See instruction leafletPollution degree 2

Connection DataConnection technology CAGE CLAMP®Input/signaling (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGOutput (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 120 x 130 x 130; Depth from upper-edge of DIN-rail;

Height without connector; Height with connector: 169 mm

Mounting type DIN-35 rail (EN 60715)Weight 2000 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

111

Page 114: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Modbus RTU Communication ModuleItem No. Pack. Unit2789-9015 1

Features:• Communication module snaps onto Pro 2 Power Sup-

plies’ communication interface• Modbus RTU (RS-485)• Suitable for monitoring the subordinate power supply• Function blocks for standard control systems available

upon request• Pluggable connection technology• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips• Requires RJ-45 terminating resistor (120 Ω) for long ca-

bles (2789-9915)

Accessories for Pro 2 Power SuppliesModbus RTU Communication Module

InputNominal input voltage Ui nom 5 VDC (SELV)Input voltage range 4.5 … 5.5 VDC (SELV)Input current Ii ≤ 40 mA

Signaling and CommunicationSignaling 1 green LED (PWR); 1 yellow LED (RxD); 1 yellow LED

(TxD)Communication Modbus RTU via RS-485Baud rate 4.8 … 115.2 kBdNumber of devices (max.) 247

Safety and Protection/Environmental RequirementsTest voltage (input/output) 2 kVAC; 50 Hz; 1 minTest voltage (input/output/shield) 1 kVAC; 50 Hz; 1 minOvervoltage category IIIPollution degree 2Insulation type Functional insulationProtection class IP20Surrounding air temperature (operation) –40 … +70 °CSurrounding air temperature (storage) –40 … +85 °CRelative humidity 5 … 95 % (non-condensing)Operating altitude (max.) 5000 m

Connection DataConnection technology 2 x RJ-45Transmission medium Shielded copper cable

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 35 x 80 x 22Mounting type Snaps onto Pro 2 Power Supplies’ communication

interface (X4)Weight 35 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

UL 61010-1; UL 61010-2-201

112

Page 115: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

IO-Link Communication ModuleItem No. Pack. Unit2789-9080 1

Features:• Communication module snaps onto Pro 2 Power Sup-

plies’ communication interface• IO-Link device supports IO-Link specification 1.1• Suitable for configuring and monitoring the subordinate

power supply• Function blocks for standard control systems available

upon request• Pluggable connection technology• Marker slot for WAGO Marker Cards (WMB) and WAGO

Marking Strips

Accessories for Pro 2 Power SuppliesIO-Link Communication Module

InputNominal input voltage Ui nom 24 VDC (SELV; via IO-Link master)Input voltage range 18 … 30 VDC (SELV; via IO-Link master)Input current Ii ≤ 15 mA

Signaling and CommunicationSignaling Red LED (ERR); Green LED (COM)Communication IO-LinkIO-Link version 1.1Baud rate 230.4 kbit/s (COM 3)Data width 5 bytesData update rate 25 ms

Safety and Protection/Environmental RequirementsIsolation 0.63 kVDCProtection class/type III / IP20 (per EN 60529)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 5 … 96 % (no condensation permissible)Pollution degree 2

Connection DataConnection technology CAGE CLAMP®Solid/fine-stranded conductor 0.08 … 2.5 mm² / 28 … 12 AWGCable length ≤ 20 m (IO-Link)

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 35 x 95 x 22; height including connector;

Depth in mounted stateMounting type Snaps onto Pro 2 Power Supplies’ communication

interface (X4)Weight 35 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61010-1; EN 61010-2-201; EN 61204-3;

EN 61000-6-2; EN 61000-6-3; UL 61010-1; UL 61010-2-201

113

Page 116: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

PELN

DC+DC+DC -DC -

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Compact; 1-Phase; 12 VDC / 2.5 A787 Series

InputNominal input voltage Ui nom 100 … 240 VAC; 140 … 340 VDCInput voltage range 90 … 264 VAC; 125 … 375 VDCInput voltage derating −1.5 %/V (< 100 VAC)Nominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii ≤ 0.6 A (100 VAC; 2.5 ADC)Inrush current ≤ 30 A (NTC)Power factor ≥ 0.5Power factor correction (PFC) PassiveMains failure hold-up time ≥ 100 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 12 VDC (SELV) / ≤ 1 %Output voltage range 10 … 14 VDC (adjustable)Nominal output current Io nom 2.5 ANominal output power 30 WResidual ripple ≤ 100 mV (peak-to-peak)Overload behavior Constant power (in overload range: 1.05 ... 1.35 x Io nom);

Shutdown and automatic restart in the event of a short circuit or permanent overload

Signaling and CommunicationSignaling 1 x LED DC OK (green)

Efficiency/Power LossesPower loss Pl ≤ 0.5 W (230 VAC; no load)Power loss (max.) Pl max. ≤ 4.5 W (100 VAC / 12 VDC; 2.5 A)Efficiency (typ.) 88 % (230 VAC; nominal load); 87.5 % (110 VAC; nominal

load);

Fuse ProtectionInternal fuse T 1 A / 250 VACRecommended backup fusing Circuit breaker: 6 A, 10 A or higher;

Tripping characteristic: B

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND) 4.242 kVDC / 2.12 kVDCProtection class/type I / IP20 (per EN 60529)Overvoltage category IIShort-circuit-protected YesParallel/series operation Yes, for devices of the same type/Yes, for two devices of

the same typeMTBF > 3,500,000 h (at 25 °C; per IEC 61709);

> 800,000 h (at 40 °C; per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 20 … 90 % (no condensation permissible)Derating −0.8 %/K (> 45 °C)Pollution degree 2

Connection DataConnection technology Push-in CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 0.2 … 2.5 mm² / 0.2 … 2.5 mm² / 24 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 54 x 90 x 52,5; Depth from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715); Screw mount (back/side)Weight 319 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61204-3; EN 60335-1; UL 508

Features:• Stepped profile, ideal for distribution boards/box-

es• Removable front panel and screw mounts for al-

ternative installation in distribution boxes or de-vices

• Pluggable picoMAX® Connection Technology (tool-free)

• Electrically isolated output voltage (SELV) per EN 60335-1

• Suitable for both parallel and series operation

Power Supply; Compact; 1-phase; Output voltage: 12 VDC; Output current: 2.5 A

Item No. Pack. Unit787-1201 1

114

Page 117: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

PELN

DC+DC+DC -DC -

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Power Supply; Compact; 1-Phase; 12 VDC / 8 A787 Series

InputNominal input voltage Ui nom 100 … 240 VAC; 140 … 340 VDCInput voltage range 90 … 264 VAC; 125 … 375 VDCInput voltage derating −2 %/V (<100 VAC); −1.33 %/V (< 140 VDC)Nominal mains frequency range 47 … 63 Hz; 0 HzInput current Ii ≤ 1.6 A (100 VAC; 8 ADC)Inrush current ≤ 30 A (NTC)Power factor ≥ 0.5Power factor correction (PFC) PassiveMains failure hold-up time ≥ 50 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 12 VDC (SELV)Output voltage range 10 … 14 VDC (adjustable)Nominal output current Io nom 8 ANominal output power 96 WResidual ripple ≤ 100 mV (peak-to-peak)Overload behavior Constant power (in overload range: 1.05 ... 1.35 x Io nom);

Shutdown and automatic restart in the event of a short circuit or permanent overload

Signaling and CommunicationSignaling 1 x LED DC OK (green)

Efficiency/Power LossesPower loss Pl ≤ 0.7 W (230 VAC; no load) Power loss (max.) Pl max. ≤ 11.8 W (100 VAC / 12 VDC; 8 A)Efficiency (typ.) 91.5 % (230 VAC; nominal load); 90 % (110 VAC; nominal

load);

Fuse ProtectionInternal fuse T 3.15 A / 250 VACRecommended backup fusing Circuit breaker: 6 A, 10 A or higher;

Tripping characteristic: B

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND) 4.242 kVDC / 2.12 kVDCProtection class/type I / IP20 (per EN 60529)Overvoltage category IIShort-circuit-protected YesParallel/series operation Yes/Yes, for 2 devices of the same typeMTBF > 1,300,000 h (at 25 °C; per IEC 61709);

> 250,000 h (at 40 °C; per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 20 … 90 % (no condensation permissible)Derating −2 %/K (> 45 °C)Pollution degree 2

Connection DataConnection technology Push-in CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 0.2 … 2.5 mm² / 0.2 … 2.5 mm² / 24 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 108 x 90 x 52.5; Depth from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715); Screw mount (back)Weight 423 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61204-3; EN 60335-1; UL 508

Features:• Stepped profile, ideal for distribution boards/box-

es• Pluggable picoMAX® Connection Technology

(tool-free)• Electrically isolated output voltage (SELV) per EN

60335-1• Suitable for both parallel and series operation

Power Supply; Compact; 1-phase; Output voltage: 12 VDC; Output current: 8 A

Item No. Pack. Unit787-1221 1

115

Page 118: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

GND

GND

GND

24 V24 V24 V

L

N

3

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Features:• Stepped profile for installation in standard distri-

bution boards• Connection technology with Push-in CAGE-

CLAMP®• Suitable for both parallel and series operation• Electrically isolated output voltage (SELV) per EN/

UL 61010-1 or EU/UL 61010-2-201

Power Supply; Compact; 1-phase; Output voltage: 24 VDC; Output current: 1.25 A

Item No. Pack. Unit787-2850 1

Power Supply; Compact; 1-Phase; 24 VDC / 1.25 A787 Series

InputNominal input voltage Ui nom 110 ... 240 VACInput voltage range 100 ... 264 VACNominal mains frequency range 47 … 63 HzInput current Ii ≤ 0.55 A (110 VAC); ≤ 0.33 A (240 VAC)Inrush current ≤ 24 A (NTC)Mains failure hold-up time ≥ 95 ms (230 VAC)

OutputNominal output voltage Uo nom/adjustment accuracy 24 VDC (SELV) / ≤ 2 %Output voltage range 24 VDC (fixed setting)Nominal output current Io nom 1.25 A (24 VDC)Nominal output power 30 WResidual ripple ≤ 60 mV (peak-to-peak)Overload behavior Hiccup

Signaling and CommunicationSignaling 1 x Status indication LED (green)

Efficiency/Power LossesPower loss Pl ≤ 0.5 W (230 VAC; no load); ≤ 4 W (230 VAC; nominal

load)Power loss (max.) Pl max. ≤ 5 W (110 VAC / 24 VDC; 1.35 A)Efficiency (typ.) 88 %

Fuse ProtectionInternal fuse T 1.25 A / 250 VACRecommended backup fusing Circuit breaker: 16 A;

Tripping characteristic: B or C

Safety and Protection/Environmental RequirementsIsolation voltage (pri.-sec./pri.-GND/sec.-GND) 3.5 kVDC / 1.4 kVDC / 0.5 kVDCProtection class/type I / IP20 (per EN 60529)Overvoltage category IIIShort-circuit-protected YesParallel/series operation Yes/YesMTBF > 2,500,000 h (per EN/IEC 61709 at +40 °C)Surrounding air temperature (operation) −20 … +70 °C (in nominal mounting position);

−20 … +55 °C (in any mounting position)Relative humidity 5 … 96 % (no condensation permissible)Derating −1.7 %/K (> +55 °C)Pollution degree 2

Connection DataConnection technology Push-in CAGE CLAMP®Input (solid/fine-stranded/AWG) 0.25 … 2.5 mm² / 0.25 … 2.5 mm² / 20 … 12 AWGOutput (solid/fine-stranded/AWG) 0.2 … 1.5 mm² / 0.2 … 1.5 mm² / 24 … 16 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 36 x 90 x 55; Depth from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715)Weight 120 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61204-3; EN 61010-1; EN 61010-2-201;

cULus 61010-1; cULus 61010-2-201; DNV GL

116

Page 119: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

DC+ DC–CTRL+CTRL–

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Pure Lead Battery Module; 24 VDC / 20 A787 Series

InputNominal input voltage Ui nom 24 VDC

OutputNominal output voltage Uo nom 24 VDCNominal output current Io nom 20 A

Energy Storage SystemBattery capacity 2.5 AhCharging current ≤ 5 AEnd-of-charge voltage 27 VDC (25 °C)

Signaling and CommunicationSignaling Battery control (C+; C-)

Fuse ProtectionInternal fuse T 25 A

Safety and Protection/Environmental RequirementsProtection class/type III / IP20 (per EN 60529)Parallel operation YesService life (typ.) 15 / 8 / 4 a (20 / 30 / 40 °C)Surrounding air temperature (operation) −40 … +60 °CPollution degree 2Self-discharge 3 % per month at 20 °CCommissioning < 6 months at 30 … 40 °C

Connection DataConnection technology CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGBattery control (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGLine length (max.) ≤ 3 m

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 86 x 186 x 160Mounting type Direct screw connection;

optional DIN-rail-mount (EN 60715)Weight 3800 g

Standards and SpecificationsApprovals/standards/specifications CE

Features:• Pure lead battery module:

12 x CYCLON battery (D cell) per module• Various mounting options• Intelligent battery management (battery control)• Optional coated PCB• Pluggable connection technology

(WAGO MULTI CONNECTION SYSTEM)

Pure Lead Battery Module;Input voltage: 24 VDC;Output current: 20 A;Capacity: 2.5 Ah; with battery control

Item No. Pack. Unit787-878/000-2500 1

117

Page 120: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

DC+ DC–CTRL+CTRL–

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Pure Lead Battery Module; 24 VDC / 40 A787 Series

Features:• Pure lead battery module:

2 x Genesis EPX battery per module• Intelligent battery management (battery control)• Optional coated PCB• Pluggable connection technology

(WAGO MULTI CONNECTION SYSTEM)

InputNominal input voltage Ui nom 24 VDC

OutputNominal output voltage Uo nom 24 VDCNominal output current Io nom 40 A

Energy Storage SystemBattery capacity 13 AhCharging current ≤ 5 AEnd-of-charge voltage 27 VDC (25 °C)

Signaling and CommunicationSignaling Battery control (C+; C-)

Fuse ProtectionInternal fuse 2 x T 25 A

Safety and Protection/Environmental RequirementsProtection class/type III / IP20 (per EN 60529)Parallel operation YesService life (typ.) 15 / 8 / 4 a (20 / 30 / 40 °C)Surrounding air temperature (operation) −40 … +60 °CPollution degree 2Self-discharge 3 % per month at 20 °CCommissioning < 6 months at 30 … 40 °C

Connection DataConnection technology CAGE CLAMP®; Push-in CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWGBattery control (solid/fine-stranded/AWG) 0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWGLine length (max.) ≤ 3 m

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 217 x 186 x 199.5Mounting type Direct screw connectionWeight 12300 g

Standards and SpecificationsApprovals/standards/specifications CE

Pure Lead Battery Module;Input voltage: 24 VDC;Output current: 40 A;Capacity: 13 Ah; with battery control

Item No. Pack. Unit787-878/001-3000 1

118

Page 121: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

IN

1+−

+−

+

−2

OUT

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Redundancy Module; Input voltage: 2 x 9 … 54 VDC; Input current: 2 x 12.5 A; Output voltage: 9 … 54 VDC; Output current: 25 A

Item No. Pack. Unit787-783/000-040 1

Features:• Redundancy module with two inputs for decoupling two

power supplies• For redundant and fail-safe power supply• With LED for input voltage monitoring on site

Redundancy Module; 24 VDC / 25 A; Ex Approval787 Series

InputNominal input voltage Ui nom 2 x 24 VDCInput voltage range 2 x 9 … 54 VDCNominal mains frequency range 0 HzInput current Ii ≤ 12.5 A (per path)

OutputNominal output voltage Uo nom 24 VDCOutput voltage range 9 … 54 VDC (Ui − Voltage drop)Voltage drop ≤ 0.8 V (input/output)Nominal output current Io nom 25 AOutput power (max.) 1350 WNominal output power 600 W

Signaling and CommunicationSignaling 1 x IN1 LED (green); 1 x IN2 LED (green); 1 x OUT LED

(green)

Efficiency/Power LossesPower loss Pl ≤ 19 W (nominal load)Efficiency (typ.) 96 %

Safety and Protection/Environmental RequirementsIsolation voltage (connectors – housing) 500 VDCProtection class/type III / IP20 (per EN 60529)Short-circuit-protected NoParallel/series operation Yes/NoMTBF > 10 million h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity ≤ 95 % (no condensation permissible)Derating −2.66 %/K (55 °C < Tu ≤ 70 °C)Pollution degree 2

Connection DataConnection technology Push-in CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 0.5 … 6 mm² / 0.5 … 6 mm² / 20 … 10 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 50 x 130 x 92; Depth from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715)Weight 470 g

Standards and SpecificationsApprovals/standards/specifications CE; UL 508; ATEX; IEC Ex;

ANSI/ISA 12.12.01 (Class I Div. 2)

Similar to illustration

119

Page 122: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

IN

1+−

+−

+

−2

OUT

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Redundancy Module; 24 VDC / 76 A; Ex Approval787 Series

Redundancy Module; Input voltage: 2 x 9 … 54 VDC; Input current: 2 x 40 A; Output voltage: 9 … 54 VDC; Output current: 76 A

Item No. Pack. Unit787-785/000-040 1

Features:• Redundancy module with two inputs for decoupling two

power supplies• For redundant and fail-safe power supply• With LED for input voltage monitoring on site

InputNominal input voltage Ui nom 2 x 24 VDCInput voltage range 2 x 9 … 54 VDCNominal mains frequency range 0 HzInput current Ii ≤ 40 A (per path); ≤ 76 A (in total)

OutputNominal output voltage Uo nom 24 VDCOutput voltage range 9 … 54 VDC (Ui − Voltage drop)Voltage drop ≤ 0.5 V (input/output)Nominal output current Io nom 76 A (UL: max. 65 A)Output power (max.) 4104 WNominal output power 1824 W

Signaling and CommunicationSignaling 1 x IN1 LED (green); 1 x IN2 LED (green); 1 x OUT LED

(green)

Efficiency/Power LossesPower loss Pl ≤ 38 W (nominal load)Efficiency (typ.) 97 %

Safety and Protection/Environmental RequirementsIsolation voltage (connectors – housing) 500 VDCProtection class/type III / IP20 (per EN 60529)Short-circuit-protected NoParallel/series operation Yes/NoMTBF > 10 million h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity ≤ 95 % (no condensation permissible)Derating −2.66 %/K (55 °C < Tu ≤ 70 °C)Pollution degree 2

Connection DataConnection technology Push-in CAGE CLAMP®Input/output (solid/fine-stranded/AWG) 1.5 … 16 mm² / 1.5 … 16 mm² / 16 … 6 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 83 x 130 x 153; Depth from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715)Weight 960 g

Standards and SpecificationsApprovals/standards/specifications CE; UL 508; ATEX; IEC Ex;

ANSI/ISA 12.12.01 (Class I Div. 2)

Similar to illustration

120

Page 123: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

S1

Vout+

Vout+

GND

S2

Vin+

Vin+

GND

5

6

1

2

3

4

7

8

µC

<________ 94 mm/3.68 inch ________> 6 mm/0.23 inch

<________

97,

8 m

m/3

.85

inch ______>

____________ _>

_>

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Electronic Circuit Breaker; 24 VDC / 0.5 A787 Series

InputNominal input voltage Ui nom 24 VDCInput voltage range 18 … 30 VDC

OutputTotal number of channels (module) 1Nominal output voltage Uo nom 1 x 24 VDCOutput voltage range 18 … 30 VDC (Ui − Voltage drop)Voltage drop ≤ 50 mVNominal output current Io nom 1 x 0.5 A (fixed setting)Trip time 4 ms … 100 sSwitch-on capacity > 50000 µF per channelSwitch-on behavior Time-delayed channel switching (load-dependent, min.

170 ms/max. 500 ms)Active current limitation No

Signaling and CommunicationSignaling 1 x Status LED (green/yellow/red/blue); 1 x Control input;

1 x Active signal output (Ui, max. 4 mA)Remote input 18 … 30 VDC signal, switches on/off and resets the

channel

Efficiency/Power LossesPower loss Pl ≤ 0.3 W (no load)Efficiency (typ.) 99 %

Fuse ProtectionInternal fuse T 15 A

Safety and Protection/Environmental RequirementsIsolation voltage (connectors – housing) 500 VDCProtection class/type III / IP20 (per EN 60529)Reverse voltage protection NoParallel operationof single channels Not permittedSeries operation NoMTBF 1,263,074 h (per MIL-HDBK-217F2)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 10 ... 95 % (no condensation permissible)Derating No deratingPollution degree 2

Connection DataNumber of jumper slots 8Connection technology Push-in CAGE CLAMP®Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWGFine-stranded conductor 0.34 … 2.5 mm² / 22 … 14 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 6 x 97.8 x 94; height from upper-edge of DIN-railMounting type DIN-35 rail (EN 60715)Weight 38 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 61000-6-2; EN 61000-6-3; UL 61010-2-201

DNV GL* (*pending)

Features:• Space-saving WAGO ECB with one channel• Reliably and safely trips in the event of an overload and

short circuit on the secondary side• Switch-on capacity > 50,000 μF• Enables the use of an economical, standard power sup-

ply• Minimizes wiring via two voltage outputs and maximizes

commoning options on both input and output sides (e.g., commoning of the output voltage on WAGO 857 and 2857 Series devices)

• Status signal – as single or group message• Reset, switch on/off via remote input or local switch• Prevents power supply overload due to total inrush cur-

rent thanks to time-delayed switching on during inter-connected operation

Electronic Circuit Breaker; 1-channel; Input voltage: 24 VDC; 0.5 A; communication-capable

Item No. Pack. Unit787-2861/050-000 1

Similar to illustration

121

Page 124: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

S2 S3S1

OUT1 (+)DC 24 V (+)

0 V

OUT2 (+)

OUT3 (+)

OUT4 (+)

0 V

2..10 A

2..10 A

2..10 A

2..10 A

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Electronic Circuit Breaker; 4-channel; Input voltage: 24 VDC; Adjustable: 2 … 10 A; communication-capable; NPN signaling

Item No. Pack. Unit787-1664/000-011 1

InputNominal input voltage Ui nom 24 VDCInput voltage range 18 … 30 VDC

OutputTotal number of channels (module) 4Nominal output voltage Uo nom 4 x 24 VDCOutput voltage range 18 … 30 VDC (Ui − Voltage drop)Voltage drop ≤ 200 mV (10 A)Nominal output current Io nom 4 x 2 / 3 / 4 / 6 / 8 / 10 A (adjustable for each channel via

selector switch)Trip time 16 ms … 100 s (load-dependent)Switch-on capacity > 50000 µF per channelSwitch-on behavior Time-delayed channel switching (load-dependent,

min. 50 ms / max. 5 s)Active current limitation No

Signaling and CommunicationSignaling 4 x LED (green/red/orange); 1 x remote control input with

inverted logic (S1); 2 x active signal output, low-side switching (S2; S3)

Remote input Reactivation of all tripped channels via 15 … 30 VDC pulse for min. 500 ms; Switching on/off any number of channels via pulse sequence

Efficiency/Power LossesPower loss Pl ≤ 0.84 W (no load); ≤ 10 W (4 x 10 A)Efficiency (typ.) 99 %

Fuse ProtectionInternal fuse T 15 A per channel

Safety and Protection/Environmental RequirementsIsolation voltage (connectors – housing) 500 VDCProtection class/type III / IP20 (per EN 60529)Reverse voltage protection NoParallel operation of single channels Not permittedSeries operation NoMTBF > 500,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 5 … 96 % (no condensation permissible)Derating ≥ 50 °C (see instruction manual)Pollution degree 2

Connection DataConnection technology CAGE CLAMP®; Push-in CAGE CLAMP®Input (+) (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWGInput (–); Output; Signaling (solid/fine-stranded/AWG)

0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 45 x 90 x 115.5; Depth from upper-edge of DIN-35 railMounting type DIN-35 rail (EN 60715)Weight 170 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 60950; EN 61000-6-2; EN 61000-6-3;

UL 508; UL 2367; DNV GL

Features:• WAGO ECB with four channels, parametrizable• Signal and control contacts with inverted logic

(low-side switching signal outputs)• Time-delayed switching of channels• One illuminated, three-colored button per channel sim-

plifies switching (on/off), resetting, and on-site diagnos-tics

• Message reports status for each channel via pulse se-quence

• Group signal reports “channel switched off” and “tripped channel”

• Remote control input for switching on/off any number of channels via pulse sequence

• Remote control input for resetting all tripped channels

Electronic Circuit Breaker; 24 VDC / 2 … 10 A; NPN Signaling787 Series

122

Page 125: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

S2 S3S1

OUT1 (+)DC 24 V (+)

0 V

OUT2 (+)

OUT3 (+)

OUT4 (+)

0 V

1..6 A

1..6 A

1..6 A

1..6 A

T

H

B

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 5 | WAGO Power Supplies

Electronic Circuit Breaker; 4-channel; Input voltage: 24 VDC; Adjustable: 1 … 6 A; communication-capable; NPN signaling

Item No. Pack. Unit787-1664/106-011 1

Features:• WAGO ECB with four channels, parametrizable• Signal and control contacts with inverted logic

(low-side switching signal outputs)• Time-delayed switching of channels• One illuminated, three-colored button per channel sim-

plifies switching (on/off), resetting, and on-site diagnos-tics

• Message reports status for each channel via pulse se-quence

• Group signal reports “channel switched off” and “tripped channel”

• Remote control input for switching on/off any number of channels via pulse sequence

• Remote control input for resetting all tripped channels

Electronic Circuit Breaker; 24 VDC / 1 … 6 A; NPN Signaling787 Series

InputNominal input voltage Ui nom 24 VDCInput voltage range 18 … 30 VDC

OutputTotal number of channels (module) 4Nominal output voltage Uo nom 4 x 24 VDCOutput voltage range 18 … 30 VDC (Ui − Voltage drop)Voltage drop ≤ 120 mV (6 A)Nominal output current Io nom 4 x 1 / 2 / 3 / 4 / 5 / 6 A (adjustable for each channel via

selector switch)Trip time 16 ms … 100 s (load-dependent)Switch-on capacity > 50000 µF per channelSwitch-on behavior Time-delayed channel switching (load-dependent,

min. 50 ms / max. 5 s)Active current limitation No

Signaling and CommunicationSignaling 4 x LED (green/red/orange); 1 x remote control input with

inverted logic (S1); 2 x active signal output, low-side switching (S2; S3)

Remote input Reactivation of all tripped channels via 15 … 30 VDC pulse for min. 500 ms; Switching on/off any number of channels via pulse sequence

Efficiency/Power LossesPower loss Pl ≤ 0.84 W (no load); ≤ 4.2 W (4 x 6 A)Efficiency (typ.) 99 %

Fuse ProtectionInternal fuse T 15 A per channel

Safety and Protection/Environmental RequirementsIsolation voltage (connectors – housing) 500 VDCProtection class/type III / IP20 (per EN 60529)Reverse voltage protection NoParallel operation of single channels Not permittedSeries operation NoMTBF > 500,000 h (per IEC 61709)Surrounding air temperature (operation) −25 … +70 °CRelative humidity 5 … 96 % (no condensation permissible)Derating No deratingPollution degree 2

Connection DataConnection technology CAGE CLAMP®; Push-in CAGE CLAMP®Input (+) (solid/fine-stranded/AWG) 0.5 … 10 mm² / 0.5 … 10 mm² / 20 … 8 AWGInput (–); Output; Signaling (solid/fine-stranded/AWG)

0.08 … 2.5 mm² / 0.08 … 2.5 mm² / 28 … 12 AWG

Physical Data/Mechanical Data/Material DataWidth x Height x Depth (mm) 45 x 90 x 115.5; Depth from upper-edge of DIN-35 railMounting type DIN-35 rail (EN 60715)Weight 170 g

Standards and SpecificationsApprovals/standards/specifications CE; EN 60950; EN 61000-6-2; EN 61000-6-3;

UL 508; UL 2367; DNV GL

123

Page 126: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

54 m

m

90 mm

45 mm18 mm

23 m

m 61,3

mm

20,5

mm

X1.1

X1.2

X1.3

X2.1

X2.2+24 V US+ 0 V

Iso OK

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 8 | WAGO Interface Modules with Specialty Functions

Ground Resistance Signaling Module; Iso OK contact; Supply voltage: 24 VDC; Module width: 18 mm

Item No. Pack. Unit789-665 1

Short description:This module signals a value falling below a non-adjustable, asymmetric isolation resistance between +24 V or 0 V of the supply voltage and ground by means of a poten-tial-free Iso OK contact and status LED. The Iso OK con-tact can be evaluated via a PLC. This status is maintained until the next measurement interval.

Features:• Can be used in grounded/ungrounded control circuits• Grounded or ungrounded control circuit mode can be

selected via slide switch• Iso OK is indicated via potential-free optocoupler con-

tact and LEDs

Iso OK ContactSwitching voltage (max.) 48 VDC (SELV)Continuous current (max.) 500 mA (no internal restriction)Number of Iso OK contacts connected in series (max.) 25 (Limit value type: 1);

32 (Limit value type: 2 and 3)Function 1 make contact (NO); closed with applied power supply

and insulation resistance > limit value

SignalingOperation status indicator 1 x LED “Status OK” (green);Signaling 1 x LED “Iso Alarm” (red);

1 x LED “Iso Alarm” 24 V – Ground (yellow);1 x LED “Iso Alarm” 0 V – Ground (yellow);1 x Signal output “Iso OK”

Supply and Power LossNominal supply voltage US 24 VDC (SELV)Supply voltage range -25 … +30 %Power consumption at nominal supply voltage ≤ 40 mAPower loss Pl ≤ 1.7 W

Fuse ProtectionRequired backup fusing The fuse must be placed in the output circuit of the

power supply.The fuse must be adapted to the power supply used and must trip safely in case of a short circuit.The module is designed for use with a 10 A circuit break-er (characteristic B or C).

Safety and ProtectionMode: grounded control circuit

Alarm at nominal voltage 4 kΩ (±1 kΩ)Hysteresis (typ.) 1 kΩResponse time 10 s

Mode: ungrounded control circuitAlarm at nominal voltage 4 kΩ (±1 kΩ)Hysteresis (typ.) 1 kΩResponse time 1 sCurrent at ground fault (24 VDC) (max.) 56 mA

Test voltageTest voltage (supply/”Iso OK” contact) 1.5 kVAC; 50 … 60 Hz; 1 min

Insulation parameters per EN/UL 61010-2-201External/Neutral conductor voltage 300 VACOvervoltage category IIPollution degree 2Insulation type (supply/”Iso OK” contact) Basic insulation

Protection class IP20

Connection DataConnection type X1.x

Connection technology Push-in CAGE CLAMP®WAGO Connector picoMAX® eCOMSolid conductor 0.25 … 1.5 mm² / 24 … 14 AWGFine-stranded conductor 0.25 … 1.5 mm² / 24 … 14 AWGFine-stranded conductor; with insulated ferrule 0.25 … 0.75 mm²Fine-stranded conductor; with uninsulated ferrule 0.25 … 1.5 mm²Strip length 8 … 9 mm / 0.31 … 0.35 inch

Connection type 2 X2.xConnection technology 2 Push-in CAGE CLAMP®WAGO Connector 2 picoMAX® eCOMSolid conductor 2 0.2 … 2.5 mm² / 24 … 12 AWGFine-stranded conductor 2 0.2 … 2.5 mm² / 24 … 12 AWGFine-stranded conductor; with insulated ferrule 2 0.25 … 1.5 mm²Fine-stranded conductor; with uninsulated ferrule 2 0.25 … 2.5 mm²Strip length 2 9 … 10 mm / 0.35 … 0.39 inch

Ground Resistance Signaling Module789 Series

124

Page 127: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

Supplementary Catalog – WAGO Electronic Interface

Volume 4, Section 8 | WAGO Interface Modules with Specialty Functions

Physical DataWidth 18 mmDepth from upper edge of DIN-rail 51 mmHeight 90 mm

Mechanical DataMounting type DIN-35 rail

Material DataWeight 40 g

Environmental RequirementsSurrounding air temperature (operation) −40 … +70 °CSurrounding air temperature (storage) −40 … +85 °CRelative humidity 5 … 95 % (non-condensing)Operating altitude (max.) 3000 m

Standards and SpecificationsConformity marking CEEMC immunity to interference EN 61000-6-2EMC emission of interference EN 61000-6-3; EN 61000-6-4

125

Page 128: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

Volume 6, WAGO Marking

ORDER

PDF Documentation

CAD Data

Marking

Parts List

Page 129: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

127Supplementary Catalog – WAGO Marking

www.wago.com Volume 6, Section 2 | WAGO Smart Data

PageWAGO Marking Software Smart Script 128

WAGO Configuration Software Smart Designer 129

Volume 6, WAGO Marking

Volume 6, WAGO Marking

Page 130: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

128 Supplementary Catalog – WAGO Marking

www.wago.comVolume 6, Section 2 | WAGO Smart Data

WAGO Marking Software Smart ScriptIntuitive Marking Software

Smart Script is WAGO’s new software for the compact Thermal Trans-fer Smart Printer. The self-explanatory and intuitive software perfectly fits all control cabinet marking requirements.

Combining superior usability with a modern design, Smart Script helps the user complete the task quickly and easily with just a few clicks. For example, Smart Script can be used to easily customize type labels, as well as define and print barcodes and graphic ele-ments.

Modern design:Appealing and intuitive workflow

All applications in one Software:Fast and easy to use, printer driver and all settings inte-grated

For any control cabinet marking application:Professional marking of terminal blocks, labels, type plates and conductor markers

Page 131: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

129Supplementary Catalog – WAGO Marking

www.wago.com Volume 6, Section 2 | WAGO Smart Data

WAGO Configuration Software Smart DesignerSmart Designer in HTML5

Updated to HTML5, WAGO’s Smart Designer Configuration Software comes with a new design and additional features. The new software offers a modern and intuitive user interface for maximum usability. In addition, mobile devices are better supported, expanding the scope of applications and allowing the software to be used at any time and from anywhere. With this future-ready web application standard, WAGO offers a tool that perfectly supports the engineering process.

All known and proven functions of the previous Smart Designer version have been retained. The updated tool allows projects from different CAE planning tools to be imported via an interface and, for example, a plausibility check to be performed. Based on WAGO’s expertise, a check is made as to whether the configured setup is possible and for rail-mount terminal blocks, e.g., the correct jumpers are set according to the planning. Alternatively, a combination of rail-mount terminal blocks or a custom connector can be created directly in the software and an offer can be requested with a click.

Future-ready web application standard

Modern, intuitive user interface

Better support for mobile devices

All known functions have been retained

Page 132: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

130

www.wago.com

Supplementary Catalog

WAGO Tools

Cable Stripper

Cable knife; for Ø 8 … 28 mm / 0.31 … 1.10 inch; with a unique, changeable cable bracket system; including cable bracket

Cable knife set; for Ø 4 … 70 mm / 0.16 … 2.75 inch; including all cable brackets in a Sortimo® Box

Item No. Pack. Unit Item No. Pack. Unit206-1403 1 206-1400 1

Item-Specific AccessoriesCable bracket; for Ø 4 … 16 mm / 0.16 … 0.63 inch

206-1411 1

Cable bracket; for Ø 8 … 28 mm / 0.31 … 1.10 inch206-1412 1

Cable bracket; for Ø 27 … 35 mm / 1.06 … 1.38 inch206-1413 1

Cable bracket; for Ø 35 … 50 mm / 1.38 … 1.97 inch206-1414 1

Cable bracket; for Ø 50 … 70 mm / 1.97 … 2.75 inch206-1415 1

AccessoriesSpare inside blade Spare hook blade

206-1418 3 206-1419 1

Never use this tool on or near live electrical circuits!

To replace the cable bracket, use the new bracket as an operating tool and pull it upwards.

The cutting depth of the hook blade can be adjusted with the slider.

The cutting depth of the inner knife can be adjusted with the screw.

Release the fuse before using the hook blade.Strip large cross sections with the hook blade.

Page 133: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

131

www.wago.com

Supplementary Catalog

WAGO Tools

Cable Stripper

In-socket cable stripper; for Ø 8 … 13 mm / 5/16 … 1/2 inch

Universal cable stripper; for Ø 8 … 13 mm / 5/16 … 1/2 inch

Data cable stripper; for Ø 4.5 … 10 mm / 3/16 … 3/8 inch

Item No. Pack. Unit Item No. Pack. Unit Item No. Pack. Unit206-1441 1 206-1442 1 206-1451 1

Product features:• Extra long design and improved force transmission sim-

plifies stripping in deep device connection sockets• Special four-blade design for an even more precise

round cut• No cutting depth adjustment required• TiN-coated blades, TÜV/GS tested• Ø 8 … 13 mm / 5/16 … 1/2 inch• Strips all standard round cables, including NYM

3 x 1.5 mm²/16 AWG … 5 x 2.5 mm²/14 AWG

Product features:• Strip outer insulation and foil sheathing with one tool• Ideal for stripping PVC-insulated data cables with thin

insulation (e.g., Cat. 5, Cat. 6, Cat. 7, twisted pair cable)• TiN-coated blades• Ø 4.5 … 10 mm / 3/16 … 3/8 inch

Sheath stripping: longitudinal cut

Product features:• Secure grip achieved with soft padding for non-slip

grips• Technically improved functionality• New locking mechanism prevents the unwanted open-

ing of the tool• Absolutely straightforward, quick and easy longitudinal

cuts – with innovative internal cable duct• Redesigned blade layout and intake to stop cable waste

from jamming the tool• Durable and ergonomically designed pocket clip• Ø 8 … 13 mm / 5/16 … 1/2 inch

Stripping a cable sheath.

Stripping a wire insulation.Built-in handy knife

Page 134: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

132

www.wago.com

Supplementary Catalog

WAGO Tools

Cable Stripper

Stripping pliers; for sensor cables; for Ø 3.2 … 4.4 mm / 0.13 … 0.17 inch

Stripping pliers; for control cables; for Ø 4.4 … 7 mm / 0.17 … 0.27 inch

Item No. Pack. Unit Item No. Pack. Unit206-1481 1 206-1482 1

Item-Specific Accessories Item-Specific AccessoriesReplacement blade set; for Ø 3.2 … 4.4 mm / 0.13 … 0.17 inch

Replacement blade set; for Ø 4.4 … 7 mm / 0.17 … 0.27 inch

206-1491 1 206-1492 1

The stripping pliers for sensor cables have a blade geom-etry specially designed for sensor cables with a smaller cross section and a working range from Ø 3.2 mm / 0.13 inch (for stranded cables and round cables with Ø 3.2 mm … 4.4 mm / 0.13 … 0.17 inch).

The stripping pliers for control cables are designed for stronger cables from Ø 4.4 mm / 0.17 inch (for stranded cables and round cables with Ø 4.4 mm … 7 mm / 0.17 … 0.27 inch).

These stripping pliers quickly and safely strip cables for connecting, e.g., sensor/actuator distribution boxes, bus couplers and pluggable connectors.

Suitable for:• Halogen-free PUR sensor/actuator cables• Highly flexible TPE-U cables• Control cables• PUR cables• PUR/PVC cables• PVC cables• Multi-core cables• Shielded and unshielded cables

Never use this tool on or near live electrical circuits!

Page 135: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

133

www.wago.com

Supplementary Catalog

WAGO Tools

Wire Stripper

Cutting a conductor.

Partially stripping a conductor.

Wire Stripper:• Automatically adjust to conductor size• Stripping blades cause no damage to conductor strands• Gripping pressure of jaws adjusts automatically to con-

ductor insulation diameter• Clamping jaws and stripping blades automatically open

once the stripping process is completed – no splaying of the conductor strands

• Exact strip length may be set by sliding black setting stop

• Stripping blades can be replaced• Self-sharpening, fully protected cutter (replaceable)• Entire body made of glass-fiber-reinforced polyamide• Cutting capacity of the wire cutter of fine-stranded con-

ductors up to 16 mm² (6 AWG)Wire stripper “Quickstrip Vario”; 0.03 … 16 mm² / 34 … 6 AWG; with wire cutter

Item No. Pack. Unit206-1125 1

AccessoriesBlade set; Standard; 0.03 … 16 mm² / 34 … 6 AWG

206-1126 1

Blade set; V-blade; 0.14 … 4 mm² / 24 … 12 AWG206-1127 1

Blade set; Oval blade; 10 … 16 mm² / 8 … 6 AWG206-1128 1

Spare stripping stop206-1129 1

Spare cut protector206-1131 1

Spare clamping jaws206-1132 1

Page 136: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

134

www.wago.com

Supplementary Catalog

WAGO Tools

Crimping tool “Variocrimp 4”; for insulated and uninsulated ferrules; Crimping range: 0.25 … 4 mm² (24 … 12 AWG)

Crimping tool “Variocrimp 16”; for insulated and uninsu-lated ferrules; Crimping range: 6 mm² (10 AWG), 10 mm² (8 AWG) and 16 mm² (6 AWG)

Item No. Pack. Unit Item No. Pack. Unit206-1204 1 206-1216 1

Spring clamp; large Spring clamp; small206-1205 1 206-1206 1

Spring clamp; small206-1206 1

Crimping Tool

Insert the ferruled conductor into the crimping station. Squeeze handles until ratchet mechanism is released.

Only for “Variocrimp 16”:Adjust conductor cross section with crimping tool in open position.

Application notes:• The built-in crimping pressure control of “Variocrimp 4”

automatically adjusts the crimping force to the conduc-tor cross section. Select the wire gauge on “Variocrimp 16” before crimping.

• Only one crimping station is needed to handle the speci-fied conductor range.

• Uniform, compact crimping on all four sides for high conductor retention.

• No need to center the ferrules into the terminal blocks.• Crimping can be performed from either side (for left- or

right-handed users).• Built-in ratchet mechanism ensures gas-tight crimp con-

nection.• Crimping tools open automatically after crimping opera-

tion is complete.• Ergonomically designed handles.

A perfect gas-tight crimp – both electrically and mechani-cally reliable

Page 137: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

135

www.wago.com

Supplementary Catalog

WAGO Tools

Crimping tool 25; for insulated and uninsulated ferrules; crimping range: 10 mm² (8 AWG), 16 mm² (6 AWG) and 25 mm² (4 AWG)

Crimping tool 50; for insulated and uninsulated ferrules; crimping range: 35 mm² (2 AWG) and 50 mm² (1/0 AWG)

Item No. Pack. Unit Item No. Pack. Unit206-1225 1 206-1250 1

Crimping Tool

Insert the ferruled conductor into the crimping station. Squeeze handles until ratchet mechanism is released.

Application notes:• Improved crimping for higher conductor retention• Crimping can be performed from either side (for left- or

right-handed users).• Built-in ratchet mechanism ensures gas-tight crimp con-

nection.• Crimping tools open automatically after crimping opera-

tion is complete.• Ergonomically designed handles.

What is a “gas-tight” connection?In a gas-tight connection, the conductor and the ferrule are compressed, eliminating all spaces. Under normal atmospheric conditions, neither a liquid nor gaseous medium can penetrate the crimped connection.Oxidation between crimped single conductors is pre-vented, virtually eliminating the possibility of any increase in the crimped connection’s resistance. In some excep-tional cases, minute, isolated spaces may be present. However, these instances can be considered as closed off due to the twisted conductor.Inadequate crimping can allow the conductor to be pulled out of the connection. Hollow spaces also remain, permit-ting oxidation formation and an increase in contact resis-tance.Elevated resistance is detrimental for both signal trans-mission (signal flow is damped) and power transmission, resulting in power loss and contact heating (risk of fire).Crimping tools with built-in ratchets are recommended (e.g., WAGO Crimping Tools). These tools open automati-cally after the crimping operation is complete. Space-sav-ing crimping from all four sides is ideal for spring clamp termination.Ferruled conductor cross sections specified for WAGO products are based on this crimping method.

Page 138: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

136

206 Series206-1125 133206-1126 133206-1127 133206-1128 133206-1129 133206-1131 133206-1132 133

206-1204 134206-1205 134206-1206 134206-1216 134206-1225 135206-1250 135

206-1400 130206-1403 130206-1411 130206-1412 130206-1413 130206-1414 130206-1415 130206-1418 130206-1419 130206-1441 131206-1442 131206-1451 131206-1481 132206-1482 132206-1491 132206-1492 132

249 Series249-198 47

750 Series750-332 49750-362/040-000 56750-363 48750-363/040-000 57750-364/040-010 58750-365/040-010 59

750-439 54750-489 55750-498 50

750-564 51

750-668/000-004 53

750-823 32750-832 33750-832/000-002 33750-890 34750-890/025-000 34750-890/025-001 34750-890/025-002 34750-890/040-000 35750-890/040-001 35750-893 32

750-8210 26750-8210/025-000 26750-8210/040-000 29750-8212/000-100 28750-8212/040-010 30750-8213/040-010 31750-8217 27750-8217/025-000 27

753 Series753-647 52753-668/000-004 53

756 Series756-1201/060-020 77756-1201/060-050 77756-1201/060-100 77756-1201/060-200 77756-1202/060-020 77756-1202/060-050 77756-1202/060-100 77756-1202/060-200 77756-1203/060-020 77756-1203/060-050 77756-1203/060-100 77756-1203/060-200 77756-1204/060-020 77756-1204/060-050 77756-1204/060-100 77756-1204/060-200 77

756-3501/050-020 76756-3501/050-050 76756-3501/050-075 76756-3501/050-100 76756-3501/050-150 76756-3502/050-020 76756-3502/050-050 76756-3502/050-075 76756-3502/050-100 76756-3502/050-150 76756-3503/050-020 76756-3503/050-050 76756-3503/050-075 76756-3503/050-100 76756-3503/050-150 76756-3504/050-020 76756-3504/050-050 76756-3504/050-075 76756-3504/050-100 76756-3504/050-150 76756-3505/050-003 76756-3505/050-005 76756-3505/050-010 76756-3505/050-020 76756-3505/050-050 76756-3505/050-075 76756-3505/050-100 76756-3505/050-150 76756-3506/050-003 76756-3506/050-005 76756-3506/050-010 76756-3506/050-020 76756-3506/050-050 76756-3506/050-075 76756-3506/050-100 76756-3506/050-150 76

758 Series758-879/000-001 26758-879/000-2108 87758-879/000-3102 20758-879/000-3108 87

758-918/000-001 86

762 Series762-4205/8000-001 20762-4206/8000-001 21762-4305/8000-002 20762-4306/8000-002 21

762-5205/8000-001 22762-5206/8000-001 23762-5305/8000-002 22762-5306/8000-002 23

762-6301/8000-002 24762-6302/8000-002 24762-6303/8000-002 25762-6304/8000-002 25

763 Series763-301 46763-351 46763-353 46763-354 46

763-1108 40763-1116 40

763-1508 41763-1516 41

763-4750/010-000 44

763-5101 42763-5120 43763-5600 45

765 Series765-1101/100-000 62765-1102/100-000 64765-1103/100-000 63765-1104/100-000 65765-1105/100-000 65

765-1701/200-000 70765-1702/200-000 72765-1703/200-000 74765-1704/200-000 71765-1705/200-000 73765-1706/200-000 75

765-4101/100-000 66765-4102/100-000 67765-4103/100-000 68765-4104/100-000 69

768 Series768-2201 39768-3301 38

787 Series787-783/000-040 119787-785/000-040 120787-878/000-2500 117787-878/001-3000 118

787-1201 114787-1221 115787-1664/000-011 122787-1664/106-011 123

787-2850 116787-2861/050-000 121

789 Series789-665 124

852 Series852-1305/000-001 78852-1322 80852-1328 81852-1505/000-001 79852-1605 84

852-602 82852-603 83

Supplementary Catalog

Indexes and Addresses

PageItem No.

Item Number Index

PageItem No. PageItem No.

Page 139: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

137

855 Series855-3001/075-003 101855-3001/125-003 101855-3001/150-003 101

855-4001/125-001 101855-4001/250-000 101855-4005/200-101 101855-4005/250-100 101

855-4101/300-001 101855-4101/500-000 101855-4105/300-101 101855-4105/500-101 101

855-5001/300-001 102855-5001/500-000 102855-5001/750-000 102855-5001/800-000 102855-5005/300-001 102855-5005/500-001 102855-5005/750-000 102855-5005/800-000 102

855-5101/250-001 102855-5101/300-001 102855-5101/400-000 102855-5101/500-000 102855-5101/600-000 102855-5101/750-000 102855-5101/800-000 102855-5105/300-001 102855-5105/400-001 102855-5105/500-001 102855-5105/600-000 102855-5105/750-000 102855-5105/800-000 102

879 Series879-3000 94879-3020 96879-3040 98

2009 Series2009-110 622009-115 622009-141 47

2759 Series2759-120/1121-1000 10

2759-203/211-1000 122759-204/261-1000 82759-206/261-1000 42759-207/271-1000 42759-208/211-1000 102759-216/211-1000 162759-241/261-1000 62759-247/211-1000 152759-266/211-1000 172759-283/211-1000 182759-286/211-1000 18

2759-401/1420-1000 14

2759-2101/271-1000 82759-2102/271-1000 82759-2103/271-1000 82759-2110/261-1000 6

2759-2283/211-1000 182759-2286/211-1000 18

2787 Series2787-2144 1042787-2146 1052787-2147 1062787-2157 1082787-2346 1092787-2347 1102787-2348 1112787-2448 107

2789 Series2789-9015 1122789-9080 113

2852 Series2852-7110 882852-7111 882852-7112 882852-7113 882852-7114 882852-7115 88

2852-7210 892852-7213 892852-7214 892852-7215 892852-7220 892852-7230 892852-7231 892852-7232 892852-7233 89

2852-7510 882852-7511 882852-7512 882852-7513 882852-7514 882852-7515 882852-7516 88

2852-7601/000-001 892852-7601/000-002 89

2857 Series2857-569 92

Products highlighted in RED are new items for Spring 2020

Supplementary Catalog

Indexes and Addresses

PageItem No. PageItem No. PageItem No.

Page 140: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

138 Supplementary Catalog

Indexes and Addresses

Algeriaplease contact WAGO France

ArgentinaBruno Schillig S.A.Arenales 4030, B1604CFDFlorida, PBAPhone +54 11 4730 1100Fax +54 11 4761 [email protected]

ArmeniaROOT ITSP LLC33 Halabyan str.0038, [email protected]

AustraliaWAGO Pty. Ltd.2-4 Overseas DriveNoble Park Victoria 3174Phone +61 03 8791 6300Fax +61 03 9701 [email protected]

AustriaWAGO Kontakttechnik Ges.m.b.H.Europaring F15 602Campus 212345 Brunn am GebirgePhone +43 1 6150780Fax +43 1 [email protected]

AzerbaijanAZ Technics LTDZulfi V. AlizadeY.Safarov str.33, AZ1025,BakuPhone +994 50 210 24 49Fax +994 12 496 83 [email protected]

Bangladeschplease contact WAGO India

BelarusDemsEnergo LLCSmolyachkova Str. 16, Office 2220005 MinskPhone: +375 17 2102189Fax: +375 17 [email protected]

ATAVA Techno Ltd.Ul. Denisovskaya 47, Office 1220006 MinskPhone: [email protected]

BelgiumWAGO BeLux nvExcelsiorlaan 111930 ZaventemPhone +32 2 717 9090Fax +32 2 717 [email protected]

BoliviaISOTEK S.R.L.Zona Casco ViejoCalle Isso #578, B/San Roque Santa CruzPhone +591 721 000 [email protected]

Bosnia & Herzegovinaplease contact WAGO Bulgaria

AM-ELEKTRIK dooDzemala Bijedica 160F71000 SarajevoPhone +38762 59 99 54Fax +38733 92 23 [email protected]

BrazilWAGO Eletroeletrônicos LtdaRua Trípoli, 640, Lotamento Multivias IIJardim Ermida IJundiaí - SP CEP 13212-217Phone +55 (11) 2923 [email protected]

BulgariaWAGO Kontakttechnik GmbH & Co. KGRepresentative Office SofiaBusiness Center Serdika2E Akad. Ivan Geshov Blvd. Building 1, Floor 4, Office 4171330 SofiaPhone +359 2 489 46 09/10Fax +359 2 928 28 [email protected]

CanadaWAGO Canada, Inc.1550 Yorkton Court - Unit 1Burlington, ON L7P 5B7Phone [email protected]

ChileDesimat ChileAv Puerto Vespucio 9670Pudahuel SantiagoPhone +56 2 747 0152Fax +56 2 747 [email protected]

ChinaWAGO Electronic (Tianjin) Co., Ltd.No.5, Quan Hui RoadWuqing Development AreaTianjin 301700Phone +86 22 5967 7688Fax +86 22 5961 [email protected]

ColombiaT.H.L. Ltda.Cra. 49 B # 91-33BogotáPhone +57 1 621 85 50Fax +57 1 621 60 [email protected]

CroatiaM.B.A. d.o.o.Frana Supila 551211 MatuljiPhone +385 51 275-736Fax +385 51 [email protected]

MICROSTAR d.o.o.Siget 18 b10020 ZagrebPhone +385 1 3647 849Fax +385 1 3636 [email protected]

Czech RepublicWAGO Elektro spol. sr. o.Rozvodova 1116/36143 00 Praha 4 - ModřanyPhone +420 261 090 143Fax +420 261 090 [email protected]@wago.com

DenmarkWAGO Denmark A/SLejrvej 173500 VærløsePhone +45 44 357 [email protected]

EcuadorECUAINSETEC CIA LTDAYugoslavia N34-110 y AzuayQuitoPhone +593 2 24 50 475Fax +593 2 22 51 [email protected]

Egyptplease contact WAGO Middle East

EstoniaEltarko OÜTreiali tee 2 door 6Peetri külaRae vald75312 HarjumaaPhone +372 651 7731Fax +372 651 [email protected]

FinlandWAGO Finland OyPerintötie 2 C01510 VantaaPhone +358 9 7744 060Fax +358 9 7744 [email protected]

FranceWAGO Contact SASParis Nord 283 Rue des Chardonnerets93290 - Tremblay en FranceB.P. 95947 - ROISSY CDG CEDEXPhone +33 1 4817 2590Fax +33 1 4863 [email protected]

GermanyWAGO Kontakttechnik GmbH & Co. KGHansastraße 2732423 MindenPhone +49 571 887-0Fax +49 571 [email protected]

GermanyWAGO Kontakttechnik GmbH & Co. KGWaldstraße 199706 SondershausenPhone +49 3632 659-0Fax +49 3632 [email protected]

Great BritainWAGO LimitedTriton Park, Swift Valley Industrial EstateRUGBYWarwickshire, CV21 1SGPhone +44 1788 568 008Fax +44 1788 568 [email protected]

GreecePANAGIOTIS SP. DIMOULASDIMOULAS AUTOMATIONSKritis Str. 2610439 AthensPhone +30 210 883 3337Fax +30 210 883 [email protected]

HondurasCILASAS S.A. de C.V.Barrio Los Andes7 Calle entre 14 y 15 Ave. N.O.P.O. Box. 1061San Pedro SulaPhone +504 2557 1146/7Fax +504 2557 [email protected]

Hong KongNational Concord Eng., Ltd.Unit A-B, 5/F.Southeast Industrial Building611-619 Castle Peak RoadTsuen Wan, N.T.Phone +852 2429 2611Fax +852 2429 [email protected]

HungaryWAGO Hungá¡ria KFTIpari Park, Gyár u. 22040 BudapestPhone +36 23 502-170Fax +36 23 [email protected]

IcelandJohan Rönning ehf / S.GudjonssonSmidjuvegur 3200 KopavogurPhone +354 520-4500Fax +354 [email protected]

IndiaWAGO Private LimitedC-27, Sector-58, Phase-IIINoida-201 301Gautam Budh Nagar (U.P)Phone +91 120 438 8700Fax +91 120 438 [email protected]

Indonesiaplease contact WAGO Singapore

Iraqplease contact WAGO Middle East

IrelandDrives & ControlsUnit F4, Riverview Business ParkNangor RoadDublin 12Phone +353 1 4604474Fax +353 1 [email protected]

IsraelComtel Israel Electronic Solutions Ltd.Bet Hapaamon20 Hataas StreetP.O. Box 6644425 Kefar-SabaPhone +972 9 76 77 240Fax +972 9 76 77 [email protected]

ItalyWAGO Elettronica SRL a Socio UnicoVia Parini 140033 Casalecchio di Reno (BO)Phone +39 051 6132112Fax +39 051 [email protected]

JapanWAGO Co. of JAPAN Ltd.Kinshicho Prime Tower1-5-7, Kameido, Koto-kuTokyo 136-0071Phone +81 3 5627 2050Fax +81 3 5627 [email protected]

JordanOxgen for Engineering Systems Co. L.L.CP.O Box: 2154 Amman11953 JordanPhone +962 79 9 860 869Fax +962 655 211 [email protected]

KazakhstanAxima LLP232/2, Ryskulov avenue050061 AlmatyPhone +7 727 356 52 91/92/93Fax +7 727 327 14 92/[email protected]@axima.kz

TOO Technik-Tradeul. i. A. Protosanova, 81070004 Ust-KamenogorskPhone +7 7232 254 064Fax +7 7232 253 [email protected] KoreaWAGO Korea Co., Ltd.Room 205 AnyangMegaValley,268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 14056, South KoreaPhone +82 31 421 [email protected]

Kosovoplease contact WAGO Bulgaria

LatviaINSTABALT LATVIA SIAVestienas iela 6Rīga, LV-1035Phone +371 6790 1188Fax +371 6790 [email protected]

LebanonGemayel Trading & ContractingRue 55, Antonins Project-Bloc LP.O. BOX 70-1096Antelias, LebanonPhone +961 3 22 30 29Fax +961 4 52 10 [email protected]

LithuaniaINSTABALT LIT UABSavanorių 187Vilnius, 2053Phone +370 52 322 295Fax +370 52 322 [email protected]

Luxembourgplease contact WAGO Belgium

MalaysiaWAGO Representative Office MalaysiaNo 806, Block A4, Leisure Commerce Square,No 9, Jalan PJS 8/9, 46150 Petaling Jaya,Selangor Darul Ehsan, MalaysiaPhone +60 3 7877 1776Fax +60 3 7877 [email protected]

HPH Materials (M) Sdn BhdNo. 4, Jalan Nilam 1/6Suban Hi-Tech Industrial Park40000 Shah AlamSelangor, D.E. MalaysiaPhone +60 3 5638 2213Fax +60 3 5638 [email protected]

Macedoniaplease contact WAGO Bulgaria

Kompjunet InzeneringVladimir Komarov 1A-3/91000 SkopjePhone +389 2 521 12 00

Maledivesplease contact WAGO India

MexicoWAGO SA de CVCarretera estatal 431 Km. 2+200Lote 99 Módulo 6Parque Industrial Tecnológico InnovsciónQuerétaroEl Marqués, Qro. 76246Phone +52 442 221 5946Fax +52 442 221 [email protected]

WAGO WorldwideCompanies and Representatives

Page 141: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

139Supplementary Catalog

Indexes and Addresses

Algeriaplease contact WAGO France

ArgentinaBruno Schillig S.A.Arenales 4030, B1604CFDFlorida, PBAPhone +54 11 4730 1100Fax +54 11 4761 [email protected]

ArmeniaROOT ITSP LLC33 Halabyan str.0038, [email protected]

AustraliaWAGO Pty. Ltd.2-4 Overseas DriveNoble Park Victoria 3174Phone +61 03 8791 6300Fax +61 03 9701 [email protected]

AustriaWAGO Kontakttechnik Ges.m.b.H.Europaring F15 602Campus 212345 Brunn am GebirgePhone +43 1 6150780Fax +43 1 [email protected]

AzerbaijanAZ Technics LTDZulfi V. AlizadeY.Safarov str.33, AZ1025,BakuPhone +994 50 210 24 49Fax +994 12 496 83 [email protected]

Bangladeschplease contact WAGO India

BelarusDemsEnergo LLCSmolyachkova Str. 16, Office 2220005 MinskPhone: +375 17 2102189Fax: +375 17 [email protected]

ATAVA Techno Ltd.Ul. Denisovskaya 47, Office 1220006 MinskPhone: [email protected]

BelgiumWAGO BeLux nvExcelsiorlaan 111930 ZaventemPhone +32 2 717 9090Fax +32 2 717 [email protected]

BoliviaISOTEK S.R.L.Zona Casco ViejoCalle Isso #578, B/San Roque Santa CruzPhone +591 721 000 [email protected]

Bosnia & Herzegovinaplease contact WAGO Bulgaria

AM-ELEKTRIK dooDzemala Bijedica 160F71000 SarajevoPhone +38762 59 99 54Fax +38733 92 23 [email protected]

BrazilWAGO Eletroeletrônicos LtdaRua Trípoli, 640, Lotamento Multivias IIJardim Ermida IJundiaí - SP CEP 13212-217Phone +55 (11) 2923 [email protected]

BulgariaWAGO Kontakttechnik GmbH & Co. KGRepresentative Office SofiaBusiness Center Serdika2E Akad. Ivan Geshov Blvd. Building 1, Floor 4, Office 4171330 SofiaPhone +359 2 489 46 09/10Fax +359 2 928 28 [email protected]

CanadaWAGO Canada, Inc.1550 Yorkton Court - Unit 1Burlington, ON L7P 5B7Phone [email protected]

ChileDesimat ChileAv Puerto Vespucio 9670Pudahuel SantiagoPhone +56 2 747 0152Fax +56 2 747 [email protected]

ChinaWAGO Electronic (Tianjin) Co., Ltd.No.5, Quan Hui RoadWuqing Development AreaTianjin 301700Phone +86 22 5967 7688Fax +86 22 5961 [email protected]

ColombiaT.H.L. Ltda.Cra. 49 B # 91-33BogotáPhone +57 1 621 85 50Fax +57 1 621 60 [email protected]

CroatiaM.B.A. d.o.o.Frana Supila 551211 MatuljiPhone +385 51 275-736Fax +385 51 [email protected]

MICROSTAR d.o.o.Siget 18 b10020 ZagrebPhone +385 1 3647 849Fax +385 1 3636 [email protected]

Czech RepublicWAGO Elektro spol. sr. o.Rozvodova 1116/36143 00 Praha 4 - ModřanyPhone +420 261 090 143Fax +420 261 090 [email protected]@wago.com

DenmarkWAGO Denmark A/SLejrvej 173500 VærløsePhone +45 44 357 [email protected]

EcuadorECUAINSETEC CIA LTDAYugoslavia N34-110 y AzuayQuitoPhone +593 2 24 50 475Fax +593 2 22 51 [email protected]

Egyptplease contact WAGO Middle East

EstoniaEltarko OÜTreiali tee 2 door 6Peetri külaRae vald75312 HarjumaaPhone +372 651 7731Fax +372 651 [email protected]

FinlandWAGO Finland OyPerintötie 2 C01510 VantaaPhone +358 9 7744 060Fax +358 9 7744 [email protected]

FranceWAGO Contact SASParis Nord 283 Rue des Chardonnerets93290 - Tremblay en FranceB.P. 95947 - ROISSY CDG CEDEXPhone +33 1 4817 2590Fax +33 1 4863 [email protected]

GermanyWAGO Kontakttechnik GmbH & Co. KGHansastraße 2732423 MindenPhone +49 571 887-0Fax +49 571 [email protected]

GermanyWAGO Kontakttechnik GmbH & Co. KGWaldstraße 199706 SondershausenPhone +49 3632 659-0Fax +49 3632 [email protected]

Great BritainWAGO LimitedTriton Park, Swift Valley Industrial EstateRUGBYWarwickshire, CV21 1SGPhone +44 1788 568 008Fax +44 1788 568 [email protected]

GreecePANAGIOTIS SP. DIMOULASDIMOULAS AUTOMATIONSKritis Str. 2610439 AthensPhone +30 210 883 3337Fax +30 210 883 [email protected]

HondurasCILASAS S.A. de C.V.Barrio Los Andes7 Calle entre 14 y 15 Ave. N.O.P.O. Box. 1061San Pedro SulaPhone +504 2557 1146/7Fax +504 2557 [email protected]

Hong KongNational Concord Eng., Ltd.Unit A-B, 5/F.Southeast Industrial Building611-619 Castle Peak RoadTsuen Wan, N.T.Phone +852 2429 2611Fax +852 2429 [email protected]

HungaryWAGO Hungá¡ria KFTIpari Park, Gyár u. 22040 BudapestPhone +36 23 502-170Fax +36 23 [email protected]

IcelandJohan Rönning ehf / S.GudjonssonSmidjuvegur 3200 KopavogurPhone +354 520-4500Fax +354 [email protected]

IndiaWAGO Private LimitedC-27, Sector-58, Phase-IIINoida-201 301Gautam Budh Nagar (U.P)Phone +91 120 438 8700Fax +91 120 438 [email protected]

Indonesiaplease contact WAGO Singapore

Iraqplease contact WAGO Middle East

IrelandDrives & ControlsUnit F4, Riverview Business ParkNangor RoadDublin 12Phone +353 1 4604474Fax +353 1 [email protected]

IsraelComtel Israel Electronic Solutions Ltd.Bet Hapaamon20 Hataas StreetP.O. Box 6644425 Kefar-SabaPhone +972 9 76 77 240Fax +972 9 76 77 [email protected]

ItalyWAGO Elettronica SRL a Socio UnicoVia Parini 140033 Casalecchio di Reno (BO)Phone +39 051 6132112Fax +39 051 [email protected]

JapanWAGO Co. of JAPAN Ltd.Kinshicho Prime Tower1-5-7, Kameido, Koto-kuTokyo 136-0071Phone +81 3 5627 2050Fax +81 3 5627 [email protected]

JordanOxgen for Engineering Systems Co. L.L.CP.O Box: 2154 Amman11953 JordanPhone +962 79 9 860 869Fax +962 655 211 [email protected]

KazakhstanAxima LLP232/2, Ryskulov avenue050061 AlmatyPhone +7 727 356 52 91/92/93Fax +7 727 327 14 92/[email protected]@axima.kz

TOO Technik-Tradeul. i. A. Protosanova, 81070004 Ust-KamenogorskPhone +7 7232 254 064Fax +7 7232 253 [email protected] KoreaWAGO Korea Co., Ltd.Room 205 AnyangMegaValley,268, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, 14056, South KoreaPhone +82 31 421 [email protected]

Kosovoplease contact WAGO Bulgaria

LatviaINSTABALT LATVIA SIAVestienas iela 6Rīga, LV-1035Phone +371 6790 1188Fax +371 6790 [email protected]

LebanonGemayel Trading & ContractingRue 55, Antonins Project-Bloc LP.O. BOX 70-1096Antelias, LebanonPhone +961 3 22 30 29Fax +961 4 52 10 [email protected]

LithuaniaINSTABALT LIT UABSavanorių 187Vilnius, 2053Phone +370 52 322 295Fax +370 52 322 [email protected]

Luxembourgplease contact WAGO Belgium

MalaysiaWAGO Representative Office MalaysiaNo 806, Block A4, Leisure Commerce Square,No 9, Jalan PJS 8/9, 46150 Petaling Jaya,Selangor Darul Ehsan, MalaysiaPhone +60 3 7877 1776Fax +60 3 7877 [email protected]

HPH Materials (M) Sdn BhdNo. 4, Jalan Nilam 1/6Suban Hi-Tech Industrial Park40000 Shah AlamSelangor, D.E. MalaysiaPhone +60 3 5638 2213Fax +60 3 5638 [email protected]

Macedoniaplease contact WAGO Bulgaria

Kompjunet InzeneringVladimir Komarov 1A-3/91000 SkopjePhone +389 2 521 12 00

Maledivesplease contact WAGO India

MexicoWAGO SA de CVCarretera estatal 431 Km. 2+200Lote 99 Módulo 6Parque Industrial Tecnológico InnovsciónQuerétaroEl Marqués, Qro. 76246Phone +52 442 221 5946Fax +52 442 221 [email protected]

WAGO WorldwideCompanies and Representatives

MoldovaSmart Delight SRLBulgara Str. 9/62001 ChisinauMoldauPhone +373 (373) 69 10 22 [email protected]

MoroccoAutomatisme & Connection Maroc23, Rue Boured2ème étage, appt4Roche Noire20300 CasablancaPhone +212 522 24 21 72/73Fax +212 522 24 21 [email protected]

Nepalplease contact WAGO India

NetherlandsWAGO Nederland B.V.Laan van de Ram 197234 BW APELDOORNPhone +31 55 36 83 500Fax +31 55 36 83 [email protected]

New Zealandplease contact WAGO Australia

Engineering Computer Services Ltd7-19 Ruffell RdHamilton, 3200New ZealandPhone +64 (0) 7 849 2211Fax +64 (0) 7 849 [email protected]

NigeriaGIL Automations Ltd.Daily Times Complex2 Lateef Jakande Rd., Agidingbi100271 Ikeja, Lagos StatePhone +234 [email protected]

NorwayWAGO Norge ASJerikoveien 201067 OsloPhone +47 22 30 94 50Fax +47 22 30 94 [email protected]

Omanplease contact WAGO Middle East

PakistanFuziLogiX Automation & ControlSuit No. 14, 5th Floor, Shan ArcadeNew Garden Town, LahorePhone +92 42 594 1503 - 4Fax +92 42 585 [email protected]

PakistanS.A. Hamid & Co.7 Brandreth RoadLahore, 54000Phone +92 42 376 500 99Fax +92 42 376 513 [email protected]

ParaguayAESAAv. Madame Lynchc/Antolin Irala2309 AsunciónPhone +59 [email protected]

Philippinesplease contact WAGO Singapore

PolandWAGO ELWAG sp. z o. o.ul. Piękna 58 a50-506 WrocławPhone +48 71 3602970Fax +48 71 [email protected]

PortugalMORGADO & CA. LDA - SEDEEstrada Exterior daCircunvalação 3558/3560Apartado 10574435 Rio TintoPhone +351 22 9770600Fax +351 22 [email protected] - Gulf European Business Development - Company W.L.L.)PO Box: 20 000Doha, QuatarPhone +974 5591 [email protected]

RomaniaWAGO Kontakttechnik GmbH & Co. KGRepresentative Office RomaniaSos. Pipera-Tunari nr. 1/1building 1, 2nd floor077190 Voluntari, IlfovPhone +40-(0)31 421 85 [email protected]

VDR & Servicii srlStr. Valeriu Branişte, nr. 60, ap.1, sector 3Phone +40 21 322 5074/76Fax +40 21 322 [email protected]

RussiaООО WAGO Contact RusIlimskaya strret 5, bldg. 2127576 MoscowPhone +7 495 [email protected]

OOO Prosoftul. Profsouznaya, 108117437 MoscowPhone +7 495 2340636Fax +7 495 [email protected]

Saudi ArabiaSaudi Electronic TradingP.O. Box 60712Riyadh 11555Phone +966 11 2063 377Fax +966 11 4633 [email protected]

Serbiaplease contact WAGO Bulgaria

Mehatronik Sistem d.o.o.Bul. Oslobodjenja 3032000 CacakPhone +381 (0)32 310 088Fax +381 (0)32 371 571Mobil +381 (0)64 877 22 [email protected]

Sigma Controls Engineering dooJovana Skerlica 2218000 NisMobil +381 (0)63 403 [email protected]

SingaporeWAGO Electronic Pte Ltd138 Joo Seng Road #06-01Singapore 368361Phone +65 62866776Fax +65 [email protected]

SlovakiaProelektro spol. s r.o.Na barine 22841 03 Bratislava - LamačPhone +421 2 4569 [email protected]

SloveniaIC elektronika d.o.o.Vodovodna cesta 1001000 LjubljanaPhone: +386 1568 01 26Fax: +386 1568 91 [email protected]

South AfricaShorrock Automation CCNellmapius drive5 Regency Drive, Route 21 Corp. Park0051 CenturionPhone +27 12 4500300Fax +27 12 [email protected]

SpainDICOMAT S.L.Avda. de la Industria, 36Apartado Correos, 1.17828108-Alcobendas (Madrid)Phone +34 91 662 1362Fax +34 91 661 [email protected]

Sri Lankaplease contact WAGO India

SwedenWAGO Sverige ABBox 11127, 161 11 BROMMABesöksadress: Adolfsbergsv. 31Phone +46 [email protected]

SwitzerlandWAGO CONTACT SARte. de l’Industrie 19Case Postale 1681564 DomdidierPhone +41/26 676 75 00Fax +41/26 676 75 [email protected]

Syriaplease contact WAGO Middle East

Taiwan R.O.C.WAGO Contact, Ltd.5F., No.168, Jiankang RdZhonghe CityTaipei County 23585, TaiwanPhone +886 2 2225 0123Fax +886 2 2225 [email protected]

ThailandWAGO Representative Office Thailand4th Floor, KS Building213/6-8 Rachada-Phisek RoadDingdaeng, Bangkok 10400Phone +66 2 6935611Fax +66 2 [email protected]

US Power Distribution Co., Ltd.4th Floor, KS Building213/6-8 Rachada-Phisek RoadDingdaeng, Bangkok 10400Phone +66 2 2763040Fax +66 2 [email protected]

Itthirit Technology Co., Ltd.Vision Business Park 2 Floor 4Soi Raminthra 55/8, Watcharapon RoadTharaeng, Bangkhen DistrictBangkok Thailand 10220Phone +66 2 347 0780Fax +66 2 347 [email protected]

Tunisiaplease contact WAGO France

TurkeyWAGO Elektronik Sanayi ve Ticaret Ltd. Şti.Tatlısu Mahallesi Arif Ay Sokak No: 1034775 Ümraniye - IstanbulPhone +90 216 472 1133Fax +90 216 472 [email protected]

UkraineNPP LogiconPredslavinskaya street, 39, Office 30303150 KievPhone +380 44 5228019Fax +380 44 [email protected]

Micropribor Ltd.4, Krzhizhanovsky Str.03142 KievPhone +380 44 392 93 86Fax +380 44 392 93 [email protected]

United Arab Emirates (UAE)WAGO Middle East (FZC)SAIF Zone, Q4-282P.O. Box 120665Sharjah, UAEPhone +971 6 5579920Fax +971 6 [email protected]

UruguayFivisa ElectricidadAvda. Urugay 127411100 MontevideoPhone +59 829 020 808Fax +59 829 021 [email protected]

USAWAGO CORPORATIONN120 W19129 Freistadt RoadGermantown, WI 53022Phone +1 262 255 6222Fax +1 262 255 3232Toll-Free: 1-800 DIN Rail (346-7245)[email protected]

VenezuelaPETROBORNAS, C.A.C.C. PLAZA AEROPUERTO - PISO 1 - LOCAL P1-B-03(8015) UNARE - PUERTO ORDAZ - ESTADO BOLÍVARREPÚBLICA BOLIVARIANA DE VENEZUELAPhone +58 286 951 3382Fax +58 286 951 [email protected]

Vietnamplease contact WAGO Germany (Minden)

Version: 02/2020Current adresses at www.wago.com

Page 142: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

140 Supplementary Catalog

Indexes and Addresses

Notes

Page 143: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

141Supplementary Catalog

Indexes and Addresses

Notes

Page 144: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

142 Supplementary Catalog

Indexes and Addresses

Notes

Page 145: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

www.wago.com

143Supplementary Catalog

Indexes and Addresses

Notes

Page 146: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies
Page 147: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies
Page 148: Automation Technology and WAGO Electronic Interface · “Building Automation and Control Networks” (BACnet) is a data transfer protocol for building automation that simplifies

0888

-100

2/01

20-6

901

- Sup

pl. C

at. A

utom

atio

n Te

chno

logy

and

Elec

troni

c In

terfa

ce 2

020/

1 US

- 03

/202

0-00

- Pr

inte

d in

Ger

man

y - S

ubje

ct to

cha

nges

WAGO Kontakttechnik GmbH & Co. KGPostfach 2880 · D · 32385 MindenHansastraße 27 · D · 32423 [email protected]

Headquarters +49 571 887 - 0Sales +49 571 887 - 44222Order Service +49 571 887 - 44333Fax +49 571 887 - 844169

WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbH.“Copyright – WAGO Kontakttechnik GmbH & Co. KG – All rights reserved. The content and structure of the WAGO websites, catalogs, videos and other WAGO media are sub-ject to copyright. Distribution or modification to the contents of these pages and videos is prohibited. Furthermore, the content may neither be copied nor made available to third parties for commercial purposes. Also subject to copyright are the images and videos that were made available to WAGO Kontakttechnik GmbH & Co. KG by third parties.”