46
All-Flash Solution Invicta Name Presenter Titel Presenter Datum A New Generation of Performance

All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

All-Flash Solution Invicta

Name Presenter Titel Presenter

Datum

A New Generation of Performance

Page 2: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 2© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Overview of Storage Concepts HDD/SSD Basics UCS Invicta OS UCS Invicta Series UCS Invicta Management Cisco UCS Services Use Cases

Topics

Page 3: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 3© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Overview of Storage Concepts

Page 4: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 4© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Source: Lazard Capital Market Research

Storage Decisions

Tape Capacity Disk Performance Disk Flash Memory/Solid State

Backup and Archiving

Data optimization technologies (e.g.

Backup and Archiving

Data optimization technologies (e.g.

All-Flash-Arrays

Capacity OptimizedPerformance Optimized

Hybrid Arrays

Caching SWCaching SW PCIe Flash Cards/SSD

Enterprise Disk Arrays

PCIe card deployment will require advanced caching in combination with some form of capacity optimized disk array in order to replicate benefits of shared storage.

Most legacy storage vendors now support standard form factor SSDs within disk arrays as Tier-1 performance optimized capacity and could be considered “hybrid” arrays.

SSD in Array Designed for HDD

Tape

Optical

7,200 RPM7,200 RPM 10,000 RPM10,000 RPM 15,0000 RPM15,0000 RPM Solid State Solid State

Overview of Enterprise Storage Concepts

Page 5: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 5© 2013-2014 Cisco and/or its affiliates. All rights reserved.

All-Flash-Architectures

Scale Up Array

•Performance is driven by controllers •Adding Storage Shelves Increases capacity

•Can’t Increase IOPS or Throughput without upgrading controllers

•Presents a Single Storage Pool

Scale Up Array

•Performance is driven by controllers •Adding Storage Shelves Increases capacity

•Can’t Increase IOPS or Throughput without upgrading controllers

•Presents a Single Storage Pool

Scale Up/Out Array

•Leverages the capacity, power and capabilities of each node (appliance)

•Specialized routers manage nodes as one or more storage pools

•Adding Nodes increases capacity and IOPS

•Presents Multiple Storage Pools

Scale Up/Out Array

•Leverages the capacity, power and capabilities of each node (appliance)

•Specialized routers manage nodes as one or more storage pools

•Adding Nodes increases capacity and IOPS

•Presents Multiple Storage Pools

Appliance •Single unit•Does not scale•Can offer a variety of features/capabilities

•Presents a Single Storage Pool

Appliance •Single unit•Does not scale•Can offer a variety of features/capabilities

•Presents a Single Storage Pool

Scale Out Storage Cluster • Increase capacity and performance by adding a node

•Each node adds a small amount of capacity, IOPS and throughput to the cluster

•Nodes are generally uniform•Presents a Single Storage Pool

Scale Out Storage Cluster • Increase capacity and performance by adding a node

•Each node adds a small amount of capacity, IOPS and throughput to the cluster

•Nodes are generally uniform•Presents a Single Storage Pool

All Flash Architectures General Rules

All Flash Architectures General Rules

Page 6: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 6© 2013-2014 Cisco and/or its affiliates. All rights reserved.

HDD/SSD Basics

Page 7: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 7© 2013-2014 Cisco and/or its affiliates. All rights reserved.

HDD Story• Access Time

- Rotational latency- Seek time

• Performance still since 1st

developed 15k rpm disk in 1999- Random r/w performance is

where spinning disks fall short – on average 200 IOPS

• Techniques to optimize performance- Short stroking- Read-ahead, Write-back

Drive level cache• RAID penalty effects

- Disk sprawl• Hard Disk easy to overwrite

- Magnetic process

Page 8: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 8© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Flash Cell vs HDD

NAND Flash Cell

Mechanical Hard Drive

Flash memory is a type of EEPROM chip consisting of a Floating gate transistor which uses a dielectric layer between the Control Gate and an additional Floating Gate:• NAND logic: all inputs=‘1’ > output=‘0’; all

other combinations > output=‘1’

Unlike HDD, data cannot be directly overwritten in SSD (P/E Cycle)

Page 9: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 9© 2013-2014 Cisco and/or its affiliates. All rights reserved.

NAND Flash Types

Single Layer Cell (SLC)• 100,000 P/E cycles• ExpensiveMulti-layer Cell (MLC)• Used in Invicta• 5000 P/E cycles• 4 times lower costTriple Level (TLC) • 1000-1500 P/E cycles• Low cost and low enduranceeMLC (Enterprise) • Mitigates degradation of

MLC

NAND ARRAYSLC MLC TLC

1 bit/cell 2 states

2 bits/cell 4 states

3bits/cell8 states

34nm 2x nm 2x nm100K (P/E) cycles/cell

3K - 5K (P/E) cycles/cell

1K (P/E) cycles/cell

000

000001

01010011

110

100101

11110111

Page 10: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 10© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Nature of flash: P/E cycles and wear out

ERASE

PROGRAM(WRITE)

NAND example

Page 11: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 11© 2013-2014 Cisco and/or its affiliates. All rights reserved.

erasing takes much more time than programing

organize erase data in greater units than program (write) data: data unit: 4KB page erase unit: 1MB block (256x 4KB pages) as Erase Block (EB)

Freeing up 4KB pages to an entire EB for erase is so called“garbage collection“.

moving valid data for garbage collection is so called “writeamplification“. Frontend writes will be amplified at thebackend and therefore wearing out cells.

Garbage Collection / Write Amplification

Page 12: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 12© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Write Amplification, Garbage Collection, Wear Levelling

• This is what happens in standard Drive controller• In UCS Garbage Collection is background task managed by UCS Invicta OS• Wear Levelling is managed by UCS Invicta OS logging of drive media usage

Write amplification!Causes more wear and write IO than necessary

More data writtenOriginal pages

Marked unusableBlock now full

Initial write toSpare pages

Garbage collection

Wear levelling tries tochoose block for copy with even distribution

1 2 3

Any change In data within Block causes

Data to be moved To new block

Page 13: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 13© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Invicta OS

Page 14: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 14© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Invicta OS Eliminates Trade-Offs

Data Persistence

Fastest Performance

Highest Protection

Write Protection Buffer

Block Translation Layer

RAID Layer

Flash Media

Page 15: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 15© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Invicta Datamanagement (dedupe off)

1. Protect • Store in Write Buffer 1. Protect • Store in Write Buffer

2. Organize • Create Write Blocks2. Organize • Create Write Blocks

3. Optimize • Write Aligned for Flash Media & RAID Protection

3. Optimize • Write Aligned for Flash Media & RAID Protection

Page 16: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 16© 2013-2014 Cisco and/or its affiliates. All rights reserved.

1. Protect • Store in Write Buffer 1. Protect • Store in Write Buffer

2. Pattern Match & Organize • Deduplicate 4K Blocks• Create Write Blocks

2. Pattern Match & Organize • Deduplicate 4K Blocks• Create Write Blocks

3. Optimize • Write Aligned for Flash Media & RAID Protection

3. Optimize • Write Aligned for Flash Media & RAID Protection

Invicta Datamanagement (dedupe addon)

Page 17: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 17© 2013-2014 Cisco and/or its affiliates. All rights reserved.

4. Optimize Writes• Write speeds are symmetric to read speeds

4. Optimize Writes• Write speeds are symmetric to read speeds

5. Virtual Garbage Collection• Evaluated and Managed by the Invicta OS

5. Virtual Garbage Collection• Evaluated and Managed by the Invicta OS

6. Virtual Garbage Collection• Blocks are invalidated in large chunks to speed up drive level garbage collection

6. Virtual Garbage Collection• Blocks are invalidated in large chunks to speed up drive level garbage collection

Invicta Datamanagement (con’t)

Page 18: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 18© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Only unique data segments are written.

AB

CD

Data is already there, so only additional pointers are stored –not the second instance of the data.

A B C D

Blocks of Data Written

E

E New data segment identified and written

First Instance Duplicate Instance Modified Instance

A B

C D

A B

C D

B

C D

E

Page 19: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 19© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Invicta OS Data Reduction details

• Every incoming write is hashed a 4K boundary• Hash function is high performance (MM3)

• Hash is compared to all existing hashes in MEMORY• Using the hash as an array index

• Upon match• Media read verifies the duplication

• A miss-match forces a unique store• A full match stores a pointer

* VAAI is only supported in performance nodes

Page 20: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 20© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Invicta FeaturesAppliance Scaling System

Architecture INVICTA OS 5.0.0 5.0.1

Symmetric Read/Writes ✔ ✔

RAID Protection ✔ ✔

Asynchronous Replication ✔ ✔

Snapshots – Copy on Write ✔ ✔

Mirroring ✔

Web Based UI/API ✔ ✔

Role Based Access Controls ✔ ✔

Data Reduction Option ✔ ✔

Thin Provisioning ✔ ✔

iSCSI, Fibre Channel ✔ ✔

Enhanced Data Protection ✔ ✔

VAAI Support* ✔ ✔

Ethernet, Fibre Channel ✔ ✔

Increase Performance and Capacity ✔

Scaling System Fabric Point to Point

Max. Routers 2

Max Nodes 6* VAAI is only supported in performance nodes

Page 21: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 21© 2013-2014 Cisco and/or its affiliates. All rights reserved.

RAID Effect: Reducing backend IOpS

Page 22: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 22© 2013-2014 Cisco and/or its affiliates. All rights reserved.

The RAID EffectProtecting data requires writing data

RAID 1/10 • Comprises mirroring (without parity or striping).

• Write Penalty = 2

RAID 5 • Comprises block-level striping with distributed parity.

• Write Penalty = 4

RAID 6 • Comprises block-level striping with double distributed parity

• Write Penalty = 6

Every protected write must be included in the total IOPS consideration

The protected writes are a penalty because they represent overhead subtracted from the IOPS pool

Page 23: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 23© 2013-2014 Cisco and/or its affiliates. All rights reserved.

RAID Effect

Storage SystemStorage System

• RAID 5• 2,500 IOPS

ApplicationApplication

•1,000 IOPS• 50/50 Write/Read

Storage SystemStorage System

• RAID 5 • 4,000 IOPS

ApplicationApplication

• 1,000 IOPS• 100% Write

Not @ Invicta!

Page 24: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 24© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Invicta Series

Page 25: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 25© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Cisco UCS Invicta Series

Up to 1.2 Million IOPSUp to 9.6 GBps** BandwidthUp to 144 TB Raw

UCS Invicta Appliance

UCS InvictaScaling System

Scalability

Modularity

Application Acceleration

Data Optimization

Multiple Workloads

Tuning-Free Performance

250,000 IOPS1.2 GBps Bandwidth3, 6, 12, 24 TB Raw

6 Node Configuration

Page 26: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 26© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Single Control PlaneAppliance Breakdown

Page 27: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 27© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Invicta Appliance

UCS Invicta Appliance

Mode ApplicationAcceleration

Data Reduction

Throughput (GBps) 1.2 1.2100% Read IOPS 220,000 250,000Blended IOPS (50%read/50%write)

205,000 180,000

100% Write IOPS 200,000 120,000Latency (Microseconds) <100 <100Size 2 RU 2 RUMax Capacity (TB) 24 TB Raw 64 TB**

**addressable capacity

Page 28: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 28© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Cisco UCS Invicta Appliance Hardware and Management Connectivity Details

• Sizes are 3TB, 6TB, 12TB and 24TB –always uses 24 drives, no hot spare

• Different part numbers depending on capacity

• Dual redundant 1200W PSU and Fans - 6 internal hot swap fans

• Power draw around 350W

• Hardware is UCS C-240 M3 • 5 x PCIe slots for IO cards and

switching fabric connection• Dedicated CIMC management

port• Use ports 1 and 2 on LOM for

Management GUI access

• Replication software – one part number

24 Drive baysKVM

connectivityPowerbutton

LEDs

Powersupplies 4 x 1Gbps LOM

P1&2 - 1Gbps mgmt.Serial

CIMC.

Page 29: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 29© 2013-2014 Cisco and/or its affiliates. All rights reserved.

DistributedControl Plane

Scaling System Breakdown

Page 30: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 30© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Adapter Installation for C710R Scaling System Router

User can populate slots 2 and 5 with the following options:• UCSW-PCIE-IM4TG – Interface

Masters 32714L Quad Port 10 GbE Server Adapter SFP+

• UCSW-PCIE-Q2564 – Qlogic QLE2564 Quad Port 8Gb Fibre Channel HBA SFP+

PCIe Slot Description1 Mellanox Infiniband HCA2 Interface Card 13 Mellanox Infiniband HCA4 Mellanox Infiniband HCA5 Interface Card 2

Page 31: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 31© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Adapter Installation for UCS Invicta Scaling System Nodes

• No user-selectable interface cards on Nodes

• Mellanox IB HCA Card for connectivity to the low latency backplane to SSRs only

• LSI RAID controller is for connectivity of locally installed SSDs

PCIe Slot Description1 NVRAM Card2 Mellanox Infiniband HCA3 Not Populated (Reserved)4 LSI RAID Controller5 Not Populated (Reserved)

Page 32: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 32© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Invicta Scaling System Architecture

Silicon Routers

Workload Acceleration

and Data Reduction

Silicon Nodes

UP TO 6UP

TO 6

Page 33: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 33© 2013-2014 Cisco and/or its affiliates. All rights reserved.

SSNSSN

SSNSSN

SSRSSR

SSNSSN

SSRSSR

SSNSSN

SSNSSN

SSNSSN

P

M

P

M

P

M

UCS Invicta Scaling System Mirroring

Page 34: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 34© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Flexible Replication Options

Appliances to Scaling Array Scaling Array to Scaling Array

Appliance to Appliance Appliance to Open Target

Linux/WindowsLinux/Windows

Page 35: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 35© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS InvictaManagement

Page 36: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 36© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Administrative GUI

• Main management tool now for Appliance and Scaling System

• Simple intuitive GUI driven by mouse left and right click operations

• Works with a browser

• Actions • Configuration management• Alerting and monitoring• Capacity planning• Protection management• Operational changes

Page 37: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 37© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Cisco Management Overview

Manages multiple UCS

Domains

Manages ACI Fabric

UCS CENTRAL

UCS DIRECTOR Centralized infrastructure control point for data center

APIC

INTELLIGENT AUTOMATION FOR CLOUD Private Cloud, PaaS (DevOps), Hybrid Cloud

Manages: UCS Invicta, Nexus, Heterogeneous and

Converged infrastructures

Manages Single UCS domain

UCS MANAGER

Page 38: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 38© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Cisco UCS Service

Page 39: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 39© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Advanced Service Fixed

Cisco UCS Preproduction Pilot ServiceProvides planning, design, and implementation expertise to conduct a pilot deployment in the customer's environment. The goal is to verify that the project will deliver the expected business and technical objectives within three weeks in one segment of the data center.

Cisco UCS Accelerated Deployment ServiceProvides planning, design, and implementation expertise to bring a unified computing project into production within four weeks in one segment of your customer’s data center.

Page 40: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 40© 2013-2014 Cisco and/or its affiliates. All rights reserved.

UCS Customized Services

Cisco UCS Planning, Design, and Implementation Service

Provides field-proven activities and deliverables along with industry-leading expertise that can be customized to a specific scope for Cisco UCS B-Series Blade Servers and C-Series Rack Servers and Cisco UCS Invicta Scaling Systems

Cisco UCS Data Migration Service

Helps customers smoothly migrate workloads to Cisco UCS; includes customizable migration planning and support to enable successful transitions to Cisco UCS solutions, including Cisco UCS Invicta Scaling Systems

Cisco UCS Application Services

Helps customers with a variety of application needs, including portfolio rationalization, cloud enablement, migration, modernization, and management and automation

Page 41: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 41© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Technical Service

Cisco SMARTnet® Service for Unified Computing helps customers optimize uptime and availability and quickly resolve issues. Cisco SMARTnet Service for Cisco UCS includes:

• Worldwide access 24 hours a day, 365 days a year to specialized technical experts in the Cisco Technical Assistance Center (TAC)

• Triage support for third-party software• Flexible hardware replacement options including: 8x5xNBD, 8x5x4, 24x7x4

and 24x7x2• Extensive self-help support • All warranty features

Cisco SMARTnet for UCS is required for the first year with the purchase of the Cisco UCS Invicta products

Page 42: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 42© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Software Application Support Service SAS

Cisco Software Application Support Service is essential to keeping business-critical applications available, secure, and operating optimally. Cisco SAS includes:

• Registered access to Cisco.com

• 24 x 7 x 365 access to Cisco Technical Assistance Center (TAC), Cisco software specialists

• Maintenance and minor software release updates

Cisco SAS is required for the first year with the purchase of the UCS InvictaDedupe Software and/or the purchase of UCS Invicta Replication software.

Page 43: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 43© 2013-2014 Cisco and/or its affiliates. All rights reserved.

Use Cases

Page 44: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Cisco Confidential 44© 2013-2014 Cisco and/or its affiliates. All rights reserved.

What workloads for UCS Invicta

Workload Details Solution

Non Persistent VDI Application StreamingGraphic Intensive VDI

Standard Non PersistentVDI

Appliance

Persistent VDI Standard Persistent VDI Scaling with DeDupe

Databases OracleMicrosoft SQL

Scaling

Analytics Cassandra,Hortonworks, MongoDB

Grid ArchitecturesIndex’s

Appliance

Page 45: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Questions?

Page 46: All-Flash Solution Invicta - Cisco...Cisco UCS Invicta Series Up to 1.2 Million IOPS Up to 9.6 GBps** Bandwidth Up to 144 TB Raw UCS Invicta Appliance UCS Invicta Scaling System Scalability

Thank you.