TOPC-E4011E-02-07413
PASOLINK NEOi LCT PASOLINK NEOi LCT LOCAL CRAFT TERMINALLOCAL CRAFT TERMINALIssueIssue--11
Provided for Training FEB 2010
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 11
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE
COMMUNICATION BETWEEN THE LCT AND THE PASOLINK NEO IS VIA THE LCT PORT OF THE CTRL MODULE.THE LCT AND THE CTRL MODULE MOUNTED ON THE PASOLINK NEO MUST BE CONNECTED USING A USB A-B TYPE CABLE. TYPE-B CONNECTS TO THE LCT PORT.
LCT PC SPECIFICATION
CPU PENTIUM-M 1.6GHz OR BETTER
RAM 512MB OR MORE
HDD 100 MB OR MORE FREE CAPACITY
DISPLAY COLOR LCD (1024x768)
CD ROM DRIVE/USB-PORT / USB CABLE WITH USB-B CONNECTOR
SOFTWARE REQUIREMENT
OS WINDOWS 2000 (ENGLISH) WITH SP4 OR HIGHERWIN DOWS XP PROFESSIONAL (ENGLISH) SP2
IE 6 WITH SP2 PR HIGHER
JAVA RUNTIME ENVIRONMENT V1.5.0_05 OR HIGHER
LCT WEB SOFTWARE (VER 2.XX.XX)
IDU AND LCT COMPATIBILITY
Current LCT: 1.xx.xx NEW LCT: 2.xx.xx
Current NEO IDUCTRL: 2.xx.xxLCT: 1.xx.xx
Current start method(Open Browser and input URL)
Current start method(Open Browser and input URL)
NEW NEO IDUCTRL: 3.xx.xxLCT: 2.xx.xx
INCOMPATIBLEPlease change LCT
New Start Method(Open Application on LCT)
There are two types of LCT version corresponding to the IDU F/W version installed. LCT WEB applet Version 1.(Rev 1.xx.xx) is installed in the IDU and the LCT WEB Version (Rev 2.xx.xx) is installed in the PC.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 22
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE
MAKE THE LCT DIALUP CONNECTION
START THE LCT FOR STDLOGIN: Admin AND ENTER PASSWORD
INSTALL USB MODEM DRIVER (NEC)INSTALL JAVA 2 RUN TIMECREATE A DIAL UP CONNECTION NAMED LCT
1
3
DEFAULT PASSWORD: 12345678
INSTALL THE LCT WEB IN THE PC2
For LCT Ver. 2.xx.xx & CTRL Ver. 3.xx.xx
INSTALL FROM THE LCT WEB SETUP FILES CD,
JAVA RUN TIME *
USB DRIVER
LCT-WEB APPLET
* In later versions Java Run Time will be included in the LCT WEB Applet
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 33
LCT LOGINLCT LOGIN
ENTER THE USER NAME “Admin” AND PASSWORD
(DEFAULT PASSWORD IS”12345678”
CLICK THE “LOGIN”
LCT WEB OPENS TO ALARM/STATUS WINDOW
1
2
Two User ID’s are defined “Admin” (with Password) and “User” (without PW )
USER ID : AdminWITH PASSWORD, ACCESS LCT FOR MONITOR & CONTROL
USER ID : UserWITHOUT PASSWORD, ACCESS LCT FOR MONITOR ONLY
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 55
NEOi NEOi -- LCT MENULCT MENU
Por
t 1
Por
t 2
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 66
NEOi/c NEOi/c -- LCT MENULCT MENU
MAINTENANCE -1MaintenanceRX SW Manual ControlTX SW Manual ControlATPC Manual ControlTX Mute ControlCW ControlMain Loopback (Near End)Main Loopback (Far End)
MAINTENANCE -2CPU ResetDownload Configuration FileDownload Program FileUpload Configuration FileDate/Time SettingPassword SettingPMON Clear
Offline MaintenanceDADE AdjustRF SUB Band SettingAntenna Alignment Mode
PROVISIONINGCH Setting -1 CH# Used Not Used
CH # LAN (Status)
CH Usage Error Report Report Not ReportCH Setting -2 AIS Generation Report
AIS Received ReportAIS Received Condition Alarm StatusAIS Activation Condition LOF LOF+HBERE1 Port Impedance (CH#) 120 ohm 75 ohm
BER Threshold High BER ThresholdLow BER Threshold
SC Assignment RS-232C / V.11/ SC LAN
LAN Port SettingSwitching Function Disabled Enabled2M Frame
LAN Port Setting Port Usage Used Not UsedSpeed & DuplexFlow Control On OffCollision Report Report Not ReportLink Loss Forwarding Disabled Enabled
MTPC TX Power [dB]ATPC Threshold Level [dBm]
TX Power ControlAdditional ATT [dB]
ATPC Threshold Level [dBm]Additional ATT [dB]ATPC Range [Max] [dB]ATPC Range [Min] [dB]ATPC Power Mode Hold Max Min
TX SW Priority Non Priority Priority No.1Condition for TX/RX SW
RX SW Maintenance Mode Manual ForcedRX SW PriorityRX SW Condition Early warning Include EW Exclude EW
HK OUT 1 to 4 setting RL3 RL4 RL5 RL6Cluster ALM Out 1 to 4 setting
Relay Setting Pasolink ALM Out settingCluster ALM IN 1 to 4 setting Disabled Enabled
TCN Threshold 15mTCN Threshold 1 dayPMON Select RX Level TCN Threshold [dBm]
SES activation 30% 15%
Others EOW2 External setting Normal InvertAlarm Correlation Capability OFF ON
Frame ID Frame ID 1 – 32
TX Power Control MTPCATPCNot Used
LAN Port Usage (Main) P1-2 Shared/ 1Port Only (Main)P1-2 Shared/ 1Port Only (SC)P1-2 Separated (Main)
LAN Capacity (Main)
Modulation Scheme QPSK16 QAM10 MB
Transmission Capacity 20MB40Mb80Mb
TX RF Frequency [MHz]
RX RF Frequency [MHz]
(1+0)
Redundancy Setting (1+0) TERM(1+1) Hot Standby TERM(1+1) Twin Path TERM
Interface 16xE1 Standard PKG (E/W LAN)16xE1
SETUPInterface PDH E1
PDH E1 with LAN
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 77
LCT WINDOWLCT WINDOW
MAIN DISPLAY AREA
SUMMARY ALARM STATUS AREAPROGRESS AREA
MENU AREA
COMMON AREA
DISPLAY THE MAIN LCT MENU AND EXPANDED MENUS FOR PROVISIONING, MAINTENANCE AND PMON
COMMON AREA DISPLAY COMMON CONTROL BUTTONS SET, LOGOUT, RELOAD.
DISPLAY THE RESULTS OF THE SET CONTROLS: “OK’ OR “NG”
DISPLAY THE SUMMARY ALARMS OF NEO MAIN UNITS AND MAINTENANCE STATUS
DISPLAY THE LOGIN NAME AND SOFTWARE VER.
DISPLAY THE DETAILS OR CONTROL ITEMS OF THE SELECTED LCT MENU ITEM
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 88
ALARM & STATUS ALARM & STATUS --PDHPDH
Modem Detail
ODU Detail
Interface Detail PMON Detail
CTRL Detail
Alarm/Status Color Code
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 99
ALARM / STATUS ALARM / STATUS -- COMMONCOMMONODU DETAIL ALARM
TX POWER: ALARM WHEN ODU TX RF POWER IS LOW (3 dB)TX INPUT: ALARM WHEN ODU IF INPUT LEVEL IS LOSTRX LEVEL: ALARM WHEN THE ODU RX RF LEVEL IS BELOW THRESHOLDAPC: ALARM WHEN THE ODU SYNTHESIZER IS UNLOCKEDODU CPU/CABLE OPEN: ALARM WHEN ODU CPU COMMUNICATION FAILS OR IF CABLE IS OPENMUTE STATUS: INDICATE THE ODU RF POWER ON /OFF STATUSTX SW STATUS: INDICATE WHICH CH IS TRANSMITTING (1+1), HOT STBY ONLY
MODEM DETAIL ALARM (COMMON)UNEQUIPPED: ALARM WHEN THE MODEM MODULE IS NOT MOUNTEDMODULE: ALARM WHEN MODEM MODULE FAIL (LSI FAILURE)LOF: ALARM WHEN RX RADIO FRAME IS ASYNCFRAME ID: ALARM WHEN THE RX RADIO FRAME ID IS DIFFERENT FROM EXPECTEDHIGH BER: ALARM WHEN RX RADIO BER REACH HBER THRESHOLD (PROVISIONING)LOW BER: ALARM WHEN RX RADIO BER REACH LBER THRESHOLD (PROVISIONING)EARLY WARNING: ALARM WHEN RX RADIO BER REACH 1X10-9 THRESHOLDMOD: ALARM WHEN MOD VCO UNLOCK AND MOD OUTPUT LOWDEM: ALARM WHEN DEM SIDE OF MODEM FAILSINPUT VOLTAGE: ALARM WHEN INPUT VOLTAGE IS OUT OF SPECIFIED LIMITSPOWER SUPPLY: ALARM WHEN PS FAILS (1+1) CONFIGURATIONIF CABLE SHORT: ALARM WHEN THERE IS A SHORT CIRCUIT IN THE IF CABLECABLE EQL: ALARM WHEN IF CABLE EQUALIZER CONTROL FAILSLINEARIZER FUNCTION: OPERATIONAL STATUS OF THE BB LINEARIZER & NOT USED STATUSLINEARIZER: ALARM WHEN THE BB LINEARIZER FAILS
RX SW STATUS: INDICATE WHICH CH IS RECEIVING (1+1) CONFIGURATION
CTRL MODULE: ALARM WHEN CTRL MODULE FAIL MMC: INDICATE MEMORY CARD INSERTED OR NOT STATUSAPS SW FAIL: ALARM WHEN APS SW OPERATION FAIL APC ONLINE STATUS: INDICATE APS ONLINE STATUS ( WORKING OR PROTECTION)
CTRL – SDH (APS)
INDICATE THE STATUS OF CH1 AND CH2 IN (1+1) CONFIGURATION
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1010
ALARM / STATUS ALARM / STATUS -- PDHPDH
PDH E1 INTFC ALARM / STATUS
INPUT LOSS CH# – WHEN NO INPUT E1 SIGNAL IS DETECTED FROM MUX
AIS GENERATED CH# – WHEN AIS IS GENERATED AND SENT TO MUXUSAGE ERROR CH# – IN A NOT USED CH, E1 SIGNAL IS DETECTED
AIS RECEIVED CH# – WHEN AIS IS DETECTED FROM MUX
Alarm-RedNormal-GrayNormal-Green
Generated-Red
Normal-WhiteNormal-Green
Generated-WhiteNormal -Gray
Received-Red
Normal-WhiteNormal-Green
Received-WhiteNormal -Gray
Alarm-RedNormal-GreenNormal-Gray
INPHASE – WHEN MAIN AND DIVERSITY PATH DELAY NOT IN PHASE (For (1+1))(In phase /Out phase)
MODULE – INTFC MODULE FAILURE ALARM (Normal / Alarm)TYPE MISMATCH – WHEN MOUNTED INTFC IS DIFFERENT FROM THE CONFIGURED (Normal/Alarm)
Items displayed here depends on the provisioning & equipment setup setting
Click to open the detail window
UNEQUIPPED – WHEN THE INTERFACE IS NOT MOUNTED (Normal/Alarm)
Gray –CH Selected not used
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1111
ALARM / STATUS ALARM / STATUS -- PDHPDH
LINK LOSS FORWARDING – WHEN ENABLED SHOW THE LLF CONDITION
SPEED & DUPLEX – INDICATE THE SPEED & DUPLEX SETTING FOR EACH PORT (SEE PROVISIONING)
LAN COLLISION – INDICATE THE COLLISION STATUS IN HALF DUPLEX MODE
LAN LINK – INDICATE THE LINK CONNECTED / LINK DISCONNECTED ALARM STATUS
Alarm-RedLink-Green
Collision-WhiteNormal-WhiteNormal -Gray
Alarm-RedNormal-GreenNormal -Gray
Alarm-RedNormal-GreenNormal -Gray
LAN related Items displayed when in Equipment Setup LAN Port usage is selected. Click to open the detail window
Click to open the detail window
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1212
ALARM & STATUS ALARM & STATUS --SDHSDH
Modem Detail
ODU Detail
Interface Detail
PMON Detail
CTRL Detail
Alarm/Status Color Code
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1313
ALARM & STATUS ALARM & STATUS --SDHSDH
Modem Detail
ODU Detail
Main/Sub Interface Detail
PMON Detail
CTRL Detail
Unavailability status
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1414
ALARM / STATUS ALARM / STATUS -- SDHSDHMODEM DETAIL ALARM (SDH)
XIF: ALARM WHEN CROSS IF INPUT LEVEL IS LOW (XPIC CONFIGURATION)XCTRL: ALARM WHEN XPIC CONTROL FAIL (XPIC CONFIGURATION)XPIC STATUS: SHOW THE XPIC STATUS “ON” OR “RESET” (XPIC CONFIGURATION)XREF: INDICATE THE REF OSCILLATOR STATUS (XPIC CONFIGURATION)LINEARIZER FUNCTION: INDICATE THE STATUS OF THE LINEARIZER FUNCTION OPR/NON OPR
TYPE MISMATCH: ALARM WHEN THE MOUNTED INTFC IS DIFFERENT FROM CONFIGUREDMODULE: ALARM WHEN THE INTFC MODULE FAILLOS (MUX): ALARM WHEN THE STM-1 INPUT FROM MUX IS LOSTLOF (MUX): ALARM WHEN THE STM-1 FRAME SYNCHRONIZATION IS LOST FROM MUXE-BER (MUX): ALARM WHEN EXCESSIVE BER IS DETECTED ON THE STM-1 FROM MUXSD (MUX): ALARM WHEN SIGNAL DEGRADE IS DETECTED FROM THE STM-1 (MUX)
INPHASE: WHEN THE PATH DELAY BETWEEN CH1 & CH2 NOT IN PHASETF: TRANSMIT FAIL (WHEN THERE IS NO STM-1 OUTPUT TO MUX)OUTPUT CONTROL: WHEN MS-AIS GENERATION IS DISABLED AND NO STM-1 OUTPUT, INDICATE
LINEARIZER: ALARM WHEN THE LINEARIZER IS NOT OPERATING PROPERLY OR FAILURE
UNEQUIPPED: ALARM WHEN THE MAIN OR SUB INTFC IS NOT MOUNTED AS PER CONFIGURATION
LOS (DMR): ALARM WHEN THE STM-1 INPUT FROM DMR IS LOSTLOF (DMR): ALARM WHEN THE STM-1 FRAME SYNCHRONIZATION IS LOST FROM DMRE-BER (DMR): ALARM WHEN EXCESSIVE BER IS DETECTED ON THE STM-1 FROM DMR SD (DMR): ALARM WHEN SIGNAL DEGRADE IS DETECTED FROM THE STM-1 (DMR)
UNDER EXECUTION
INTFC – SDH (APS)
IN SDH CONFIGURATION, MAIN (1) FOR ELECTRICAL OR OPTICAL OR LAN INTERFACE
SUB (2) INTERFACE IS USED FOR WS/SC LAN OR AS PROTECTION CHANNEL FOR APS
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1515
ALARM / STATUS ALARM / STATUS -- PMONPMONTCN ALARM STATUS - SDH
TCN ALARM STATUS - PDH
THRESHOLD CROSSING NOTIFICATION (TCN) OF PERFORMANCE MONITOR ITEMS FOR RADIO AND BASEBAND SIGNALS ARE DISPLAYED HERE. WHEN THE PMON ITEM EXCEED ITS ALARM THRESHOLD SETTING ALARM IS INDICATED FOR THAT ITEM.
INDICATE UN-AVAILABLE EVENT OCCURRENCE FROM RADIO AND MUX SIDES
INDICATE WHEN THE RECEIVE LEVEL IS BELOW THE RX THRESHOLD LEVEL SET IN PROVISIONING FOR THE RADIO
WORK AND PROT INDICATED IN APS CONFIGURATION
RX LEVEL BELOW RX THRESHOLD LEVEL SET IN PROVISIONING FOR CH1 AND CH2
INDICATE FOR PDH CONFIGURATION, TOTAL ALARM FOR 15 MIN OR 1-DAY, PMON ITEMS EXCEEDING THEIR THRESHOLD SETTING
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1616
NEOi NEOi -- EQUIPMENT SETUP EQUIPMENT SETUP -- PDHPDHLCT EQUIPMENT SETUP
User Interface PDH E1 PDH E1 with LAN PDH 4Port LAN with E1
Redundant Setting
1+0 (TERM) 1+0 (TERM) 1+0 (TERM) 1+0 (TERM) 1+0 (TERM)
1+1 (Hot standby TERM) 1+1 (Hot standby TERM) 1+1 (Hot standby TERM) 1+1 (Hot standby TERM) 1+1 (Hot standby TERM)
1+1 (Twin Path TERM) 1+1 (Twin Path TERM) 1+1 (Twin Path TERM) 1+1 (Twin Path TERM) 1+1 (Twin Path TERM)
2-WAY PDH
INTFC Main (Work) 48 x E1 PKG16E1 Standard PKG
( E/W LAN)16E1 2-way/XC PKG
(E/W LAN)32E1 Standard PKG
(E/W LAN)4Port LAN with E1
XPIC (SDH Only)
INTFC SUB (Prot)(SDH ONLY)
APS Function(SDH ONLY)
Modulation Scheme QPSK/16QAM/32QAM QPSK / 16QAM QPSK / 16QAM QPSK/16QAM/32QAM QPSK/16QAM/32QAM
Transmission Capacity (Mbps)
40 40 40 40 40 40 40 40 40 40
80 100 80 80 80 100 80 100
For Dir-A & Dir-B
TX RF Freq-1 (1+0) or (1+1) HSBY or (1+1) Twin Path TX RF Freq Dir-A (1+0) or (1+1) HSBY or (1+1) Twin Path
TX RF Freq-2 (1+1) Twin Path TX RF Freq Dir-B (1+1) Twin Path
RX RF Freq-1 RX RF Freq Dir-A
RX RF Freq-2 RX RF Freq Dir-B
LAN Usage Yes (Main/SC) Yes (Main/SC) Yes (Main/SC) Yes (Main)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1717
NEOi NEOi -- EQUIPMENT SETUP EQUIPMENT SETUP -- SDHSDH
LCT EQUIPMENT SETUP
User Interface SDH STM-1 SDH 2Port LAN over STM-1 SDH GbE over STM-1
Redundant Setting
1+0 (TERM) 1+0 (TERM) 1+0 (TERM)
1+1 (Hot standby TERM) 1+1 (Hot standby TERM) 1+1 (Hot standby TERM)
1+1 (Twin Path TERM) 1+1 (Twin Path TERM) 1+1 (Twin Path TERM)
INTFC Main (Work)STM-1 (Electrical) 2Port LAN over STM-1 GbE over STM-1
STM-1 (Optical)
INTFC SUB (Prot)
STM-1 Optical for APS Mode
WS / LAN WS / LAN
WS WS
Not Used
XPIC
Not Used
Used (Main Mater)
Used (SUB Mater)
APS FunctionUn Available
Available
Modulation Scheme 126QAM 128QAM 128QAM
Transmission Capacity (Mbps) 156 156 156
TX RF Freq-1 (1+0) or (1+1) HSBY or (1+1) Twin Path
TX RF Freq-2 (1+1) Twin Path
LAN Usage Yes (SC) Yes (Main/SC) Yes (Main/SC)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1818
NEOi/c NEOi/c -- EQUIPMENT SETUPEQUIPMENT SETUP
User Interface PDH E1 PDH E1 with LAN
Redundant Setting1+0 1+0 (TERM)
1+1 (Hot standby TERM)1+1 (Twin Path TERM)
INTFC 16x E1 16xE1 Standard PKG (E/W LAN)
Modulation Scheme QPSK 16QAM QPSK 16QAM
Transmission Capacity
10 10 10 10
20 20 20 2040 40 40 40
80 80
TX RF Frequency (No.1)(MHz) (1+0) (1+0 FIX) or (1+1) Hot Standby or (1+1) Twin Path
TX RF Frequency (No.2)(MHz) (1+1) Twin Path
RX RF Frequency (No.1)(MHz) (1+0) (1+0 FIX) or (1+1) Hot Standby or (1+1) Twin Path
RX RF Frequency (No.2)(MHz) (1+1) Twin Path
Frame ID 1 to 32
TX Power Control ATPC or MTPC
LAN Port Usage
Not UsedP1-2 Shared/1 Port only (Main)
P1-2 Separated (Main)P1-2 Shared/ 1 Port (SC)
LAN CapacitySelect the transmission capacity used for LAN
Remaining capacity is for E1 traffic
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 1919
EQUIPMENT SETUPEQUIPMENT SETUP
WHEN SDH INTFC IS SELECTED
AFTER SELECTING ALL THE CONFIGURATION SETTINGS CLICK THE
SET BUTTON TO IMPLEMENT THE
SETTING
WHEN PDH INTFC IS SELECTED
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2020
EQUIPMENT SETUPEQUIPMENT SETUP--PDH SETTINGPDH SETTING
User Interface:- Select the BB interface to be configured, the drop down menu shows the currently available options
Redundancy Setting:- Select the redundancy setting from the drop down menu options
Interface (Work):- In the case of PDH only one (work) interface slot is available. Select the interface to be used
Interface (PROT):- Available for SDH configuration only, used for APS or WS/LAN options
Modulation Scheme:- Available Modulation scheme depends on the selected user interface and Interface Package
Transmission capacity:- Available Transmission capacity depends on the User Interface & INTFC setting
Click the Arrow to see the available options in the drop down menu
1
2
3
4
5
6
16 E1 Standard PKG (E/Q LAN)
16 E1 Standard PKG (E/W LAN)
48 x E1 PKG
E3 PKG (E/W LAN)
123
65
4
REDUNDANCY SETTING
THE FIRST SECTION IN THE EQUIPMENT SETUP IS USED TO SELECT:
THE TYPE OF USER INTERFACE
MODULATION SETTINGTRANSMISSION CAPACITY SETTING
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2121
EQUIPMENT SETUP EQUIPMENT SETUP –– FREQUENCY SETTINGFREQUENCY SETTING
TX START FREQUENCY
TO OBTAIN THE ODU FREQ INFORMATION ODU SHOULD BE CONNECTED TO THE IDU VIA THE IFL CABLE.
NO. 2 INFORMATION IS SHOWN FOR (1+1) REDUNDANCY CONFIGURATION ONLY.
FOR 6/7/8 GHz BANDS SET THE TX FREQUENCY MARKED ON THE ODU LABEL
FOR OTHER FREQUENCY BANDS ENTER A TX POINT FREQUENCY AT LEAST HALF THE CHANNEL SPACING INSIDE THE ODU START AND STOP FREQUENCIES.
FOR (1+0) AND (1+1) HOT STANDBY REDUNDANCY CONFIGURATION ENTER ONLY ONE TX FREQUENCY.
FOR (1+1) TWIN PATH REDUNDANCY CONFIGURATION ENTER NO.1 & NO.2 TX FREQUENCIES.
RX FREQUENCY IS AUTOMATICALLY SET USING THE ASSIGNED SHIFT FREQUENCY
FOLLOWING ODU FREQUENCY INFORMATION ARE SHOWN:
TX STOP FREQUENCY
RX START FREQUENCY
RX STOP FREQUENCY
SYNTHESIZER FREQUENCY STEPSHIFT FREQUENCY ( DIFFERENCE BETWEEN TX AND RX FREQUENCIES)UPPER/LOWER ( ODU IS FOR TX LOWER OR TX UPPER FREQUENCY)
SUB BAND ( SUB BAND USED IN THE ODU)
1
23
4
56
78
1
2
3
4
5
6
7
8
9
10
9
10
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2222
EQUIPMENT SETUP EQUIPMENT SETUP –– OTHEROTHER
CLICK AND SELECT THE FRAME ID. FROM THE DROP DOWN MENU. IN THE CASE OF TWIN PATH IT IS POSSIBLE TO SET THE FRAME ID FOR BOTH NO.1 & NO.2 FREQUENCIES. FRAME ID SELECTABLE RANGE IS ID1 TO ID32.
SELECT P1-2 SHARED/1 PORT ONLY (MAIN) TO SHARE THESELECTED TRANSMISSION CAPACITY WITH E1 AND LANTRAFFIC.
FRAME ID:
SELECT THE TX POWER CONTROL MODE TO BE USED MTPC OR ATPC.
TX POWER CONTROL:
THIS ITEM IS ACTIVE IF THE PDH INTFC IS EQUIPPED WITH LAN PORTS.
LAN PORT USAGE:
SELECT P1-2 SHARED/1 PORT ONLY (SC) TO USE THE SERVICE CHANNELS FOR THE LAN TRAFFIC
IF THE LAN PORT USAGE IS (MAIN), THEN SELECT THE CAPACITY FOR LAN TRAFFIC
LAN CAPACITY:
IF THE LAN PORT USAGE IS (SC), THEN SELECT THE CAPACITY FOR LAN TRAFFIC FROM THE SERVICE CHANNELS 1 TO 4
SELECT NOT USED IF LAN PORTS ARE NOT USED
FRAME ID IDENTIFIES THE CORRECT TRANSMITTED RADIO SIGNAL AT THE RECEIVING END
SELECT P1-2 SEPARATED (MAIN) TO MAKE THE TRANSMISSION OF PORT 1 AND PORT 2 SEPARATE.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2323
EQUIPMENT SETUP EQUIPMENT SETUP –– SDH SETTINGSDH SETTING
User Interface:- Select the BB interface to be configured, the drop down menu shows the currently available options
Redundancy Setting:- Select the redundancy setting from the drop down menu options
Main (Work):- In the case of SDH Select Electrical or optical or( LAN Future)
Sub (PROT):- Available for SDH configuration only, Select SC LAN/WS or Optical INTFC for APS
XPIC Usage:- Select XPIC used or not. If used select the NE to be set as Main Master or Sub Master
Modulation Scheme:- For SDH configuration only 128 QAM can be selected
Click the Arrow to see the available options in the drop down menu
APS Function:- If the Main Interface and SUB Interface are Optical then select APS Function usage
Transmission capacity:- For SDH configuration only 156MB can be selected
1
2
3
4
5
6
7
8
123
65
4
GbE over STM-1
GbE over STM-1
Not Used
WS / LANWS
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 242424
- Separated modeGUARANTEED BANDWIDTH
16 E1 with 2 – Port LAN INTFC
32E1 with 2 – Port LAN INTFC 4 Port LAN INTFC
LAN Port Usage
Port 1 -2 separated (main) Port 1 -2 separated (main) Port 1 - 4 separated (main)
Transmission Capacity
10* 20* 40 80 10* 20* 40 80 100 10* 20* 40 80 100
P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4
- - 10 10 4 4 24 24 - - - - 10 10 8 8 18 18 - - 6 6 6 6
- - 10 10 30 30 - - - - 20 20 10 10 20 20 - - 10 10 10 10
- - 20 20 40 40 - - - - 20 20 30 30 - - 16 16 16 16
- - 30 30 40 40 - - 20 20 20 20
40 40 50 50 - - 25 25 25 25
E1 CAPACITY
5 16/10/0 16/10/0 5 10/0 20/10/0 32/30/20/10/0
32/30/20/10/0
- - 8 & 0 8 & 0 4
* Not applicable to NEOi
2 Port LAN INTFC (SDH)
LAN Port Usage Port 1 – 2 Separated
Port-1 Port-2
75 75
100 50
100 disable
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2525
Separated mode
GUARANTEED BANDWIDTH
Interfaces:16 E1 with 2 Port LAN (with & without XC) INTFC (PDH)
2 Port LAN INTFC (SDH)
32 E1 with 2 Port LAN INTFC (PDH)4 Port LAN INTFC (PDH) (INTFC-E with VLAN)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 262626
SEPARATED MODE (PDH)
P1P2
16 E1 & 2 PORT LAN INTFC
P1P2
32 E1 & 2 PORT LAN INTFC
P1&P2 SHAREDP3&P4 SHARED
P1
P2
P3
P4
4 PORT LAN INTFC
QPSK16 QAM
32 QAM
QPSK16 QAM
32 QAM
QPSK16 QAM
32 QAM
QPSK16 QAM
32 QAM
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 272727
SHARED MODE (PDH)
16E1 with 2-Port LAN INTFC 32E1 with 2-Port LAN INTFC 4-Port LAN INTFC ( with 8E1)
Port 1-2 Shared / 1 Port only (Main) Port 1-2 Shared / 1 Port only (Main) Port 1-4 Shared / Port 1 only (Main)
Tran
smissio
n C
apacity
10* 20* 40 80 10* 20* 40 80 100 10* 20* 40 80 100
P1 – P2 Shared P1 – P2 Shared P1 – P4 Shared
0 0 8 48 0 16 36 24 64 100
2 2 10 50 2 18 38 26 66
4 4 12 52 4 20 40 28 68
6 6 14 54 6 22 42 30 70
8 8 16 56 8 24 44 32 72
10 10 18 58 10 26 46 34 74
12 20 60 12 28 48 36 76
14 22 62 14 30 50 38 78
16 24 64 16 32 52 40 80
18 26 66 18 34 54
20 28 68 20 36 56 P1 – P2 Shared / P3 –P4 Shared
30 70 22 38 58 12/12 32/32 50/50
32 72 24 40 60 20/20 40/40
34 74 26 42 62
36 76 28 44 64
38 78 30 46 66
40 80 32 48 68
34 50 70
36 52 72
38 2M steps 2M steps *not for NEOi
* Not for NEOi *not for NEOi 40 80 100 Yellow no E1
E1 Capacity 5 to 0 10 to 0 16 to 0 16 to 0 20 to 0 32 to 0 32 to 0 8 to 0 8 to 0 4
Switching Function Enabled – Switching HUB Enabled – Switching HUB Enabled – Switching HUB
Disabled – Data Distribution Disabled – Data Distribution Disabled – data distribution
Switching HUB Data distribution
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 282828
SHARED MODE (PDH)
PORTS 1 & 2 SHARED
PORTS 1 ~ 4 SHARED32 QAM
32 QAM
16 QAM
32 QAM
16 QAM
QPSK/16 QAM
QPSK/16 QAM
QPSK/16 QAM
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 2929
BEST EFFORT / E1 NETWORK CONNECTIONBEST EFFORT / E1 NETWORK CONNECTION
THIS MODE IS AVAILABLE FOR 2 PORT LAN INTERFACE FOR (SDH)
TWO PORTS ARE SEPARATED AND THE RADIO BAND IS SHARED IN ACCORDANCE WITH THE TRAFFIC QUANTITY OF EACH PORT. IT DOES NOT GUARANTEE CAPACITY FOR EACH PORT
BEST EFFORT
E1 NETWORKING
THIS MODE IS USED TO SEND AN ETRHERNET SIGNAL OVER AN E1 NETWORK
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3030
ETHERNET CONFIGURATIONS – 2WAY XC16E1 INTFC + 2way XC Mode
Separated Shared Shared/Switching Star Mixed
Terminal yes yes yes No No
2 Way No yes yes yes yes
40Mbps(20E1) 80Mbps(40E1)
Main LAN yes yes
SC LAN no no
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3131
PROVISIONING PROVISIONING –– PDH/SDHPDH/SDH
16E1 & 2Port LAN 16E1 & 2Port
LAN with 2Way DXC
STM-1 Interface STM-1 INTFC with sub Interface WS/LAN
LAN INTFC with sub Interface WS/LAN
PDH INTFC SDH INTFC
48E1 Interface
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3232
PROVISIONING PROVISIONING –– PDHPDH
WHEN MTPC IS SELECTED IN EQUIPMENT SETUP
WHEN ATPC IS SELECTED IN EQUIPMENT SETUP
TOPC-E4011E-02-07413 PASOLINK NEO/c LCT PASOLINK NEO/c LCT 3333
PROVISIONING PROVISIONING –– SC ASSIGNMENT SC ASSIGNMENT
NEOi/c
A TOTAL OF 3 SERVICE CHANNEL INTERFACE CAN BE USED. SC1 CAN BE USED BY EITHER RS232C-1 OR V11-1 PORT (V11-1 AND RS232C-1 CANNOT BE USED AT THE SAME TIME). SC2 CAN BE USED BY RS232C-2 PORT AND SC3&4 CAN BE USED BY V11-2 PORT.
RS232C-1 &2 IS 9.6 KBPS AND V11-1 IS 64KBPS AND V11-2 IS 9.6 KBPS
IF V11-1 IS USED, DIRECTION SETTING IS ENABLED.
IF SC LAN IS USED, THE AVAILABLE SERVICE CHANNEL THAT CAN BE USED WILL BE CHANGED DEPENDING ON THE SC LAN CAPACITY SET IN EQPT CONFIGURATION
CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL .
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
NEOi
TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE DIRECTION OF MUX OR RADIO (DMR).
E1 (MUX) E1 (DMR)F1 (DMR)F1 (MUX)
E1 (MUX)F1 (MUX)
DCCr (MUX)V.11
DSC1 TO 4V.11 & RS-232C
DCCr (DMR) DCCr (MUX)
SC LAN DSC1 TO 4
V.11 & RS-232CV.11 & RS-232C
SDH
CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL . WHEN V.11 CH IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3434
PROVISIONING PROVISIONING –– PDH LAN SETTINGPDH LAN SETTING
WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARS
THIS MENU CONFIGURE THE LAN PORT PARAMETERS WITHIN THE LAN CAPACITY (MAIN) AND LAN PORT USAGE (MAIN) SETTING IN THE EQUIPMENT SETUP
LAN PORT SETTING FOR 16E1 AND 2-PORT LAN INTERFACE CARD
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3636
PROVISIONING PROVISIONING –– BER THRESHOLD SETTING (SDH)BER THRESHOLD SETTING (SDH)
SELECT THE BER THRESHOLD SETTING FOR THE RADIO LINK AND FOR THE STM-1 SIGNAL FROM MUX & RADIO DIRECTIONS.
TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE DIRECTION OF MUX OR RADIO (DMR).
E1 (MUX) E1 (DMR)F1 (DMR)F1 (MUX)
E1 (MUX)F1 (MUX)
DCCr (MUX)V.11
DSC1 TO 4V.11 & RS-232C
DCCr (DMR) DCCr (MUX)
SC LAN DSC1 TO 4
V.11 & RS-232CV.11 & RS-232C
SDH
CLICK ON THE APPROPRIATE RADIO BUTTON TO SELECT THE THRESHOLD SETTING
CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL . WHEN V.11 CH IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3737
PROVISIONING PROVISIONING –– STMSTM--1 SETTING1 SETTING
MS-AIS GENERATION SETTING IS USED TO STOP SENDING MS-AIS SIGNAL DUE TO RADIO LINK OR EQUIPMENT FAILURE.
WHEN DISABLED:- DURING FAILURE OPTICAL INTFC WILL STOP TRANSMITTING THE OPTICAL SIGNAL, ELECTRICAL INTFC WILL SEND UNFRAMED AIS.
WHEN ENABLED:- SEND MS-AIS DUE TO RADIO LINK OR EQUIPMENT FAILURE.
AUTOMATIC LASER SHUT DOWN (ALS) FUNCTION IS AVAILABLE ONLY FOR OPTICAL INTFC . DURING LOS OF SIGNAL AT THE INPUT OF THE OPTICAL INTFC IT WILL CUT THE LASER OUTPUT FROM THE OUTPUT OF THE OPTICAL INTFC. DURING THIS TIME AT DEFINED INTERVALS INTFC WILL OUTPUT A 2 SEC LASER PULSE.
SELECT ENABLE OR DISABLE FROM THE ALS FUNCTION RADIO BUTTON
IF ENABLE IS SELECTED, SELECT ALS INTERVAL FROM 60, 180, AND 300 SEC .
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3838
PROVISIONING PROVISIONING -- APSAPS
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
APS CONDITION –SF (PROT) APPLIES WHEN FORCED MANUAL SWITCHOVER TO PROTECTION INTFC IS MADE
PRIORITY HIGH: WHEN SIGNAL FAIL (SF) OCCURS IN THE PROTECTION INTFC, KEEPS THE ONLINE, ON WORK INTFC
PRIORITY LOW: IGNORE THE SIGNAL FAIL CONDITION IN FORCED MANUAL, SWITCHOVER TO PROT INTFC
THIS MENU ITEM APPEARS WHEN APS FUNCTION AVAILABLE, IS SET IN THE SETUP CONFIGURATION. OPTICAL INTFC SHOULD BE MOUNTED IN MAIN & SUB SLOTS
APS MAINTENANCE MODE:
MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED INTFC (ROUTE)
FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED INTFC DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)
APS CONDITION –SD (B1)
INCLUDE SD: SELECT THIS TO CONSIDER STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
EXCLUDE SD: SELECT THIS TO EXCLUDE STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
LOCK IN USAGE
USED: WHEN FREQUENT SWITCHING OCCURS BETWEEN WORK & PROT, PAUSE SWITCHOVER UNTIL CONDITIONS SET IN LOCK IN COUNT, LOCK IN DETECT TIME & LOCK IN HOLD TIME ARE MET
NOT USED: ALLOW FREQUENT SWITCH OVER BETWEEN WORK & PROT INTFC.
LOCK IN USAGE SET TO USED
LOCK IN COUNT: NUMBER OF SWITCHOVERS DETECTED WITHIN LOCK IN DETECT TIME TO PAUSE SWITCHOVER ACTION
LOCK IN DETECT TIME: SET THE TIME IN MINUTES. DURING WHICH THE NUMBER OF SWITCHOVER ARE COUNTED FOR LOCK IN FUNCTION
LOCK IN HOLD TIME: SET THE DURATION OF SWITCHOVER PAUSE IN HOURS AFTER LOCK IN IS SET.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 3939
PROVISIONING PROVISIONING –– COMMONCOMMON
RX SW MAINTENANCE MODE:
MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED CHANNEL (ROUTE)
FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED CH DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)
RX SW CONDITION EARLY WARNING:
INCLUDE EW: SELECT THIS TO INCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION
EXCLUDE EW: SELECT THIS TO EXCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION
EARLY WARNING BER SETTING IS 1E-9
TX & RX SW PRIORITY
NON PRIORITY: SELECT THIS FOR NON HOMING SWITCHING.
PRIORITY NO.1: SELECT THIS FOR HOMING SWITCHING. WHEN BOTH CHANNELS ARE NORMAL USE No.1 AS ONLINE. CH NO.1 FAILS SWITCH TO CH NO.2, WHEN CH NO.1 IS NORMALIZED SWITCH BACK TO CH NO.1 AUTOMATICALLY
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4040
PROVISIONING PROVISIONING –– TX POWER CONTROLTX POWER CONTROL
No.1 & No.2 IS INDICATED FOR (1+1) TWIN PATH CONFIGURATION
MTPC MODE:
MPTC TX POWER : ENTER A NEGATIVE VALUE IN dB (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE
(SET IN 1 dB STEPS)
TX POWER CONTROL - ATPC TX POWER CONTROL - MTPC
ATPC MODE:
ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE
ADDITIONAL ATT: 0 TO 5 dB ADDITIONAL ATTENUATION IN 1 DB STEPS ( IN ADDITION TO THE ATPC RANGE) (DEPENDS ON THE MODULATION)
ATPC RANGE (MAX): MAXIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC RANGE (MIN): MINIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)
ATPC POWER MODE: THIS ITEM DEFINED THE ODU TX POWER SETTING DURING ATPC CONTROL FAILURE
HOLD: TO MAINTAIN THE CURRENT TX POWER AT THE TIME OF ATPC CONTROL FAILURE
SELECT : MAX: TO TRANSMIT AT ATPC MAX POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE
MIN: TO TRANSMIT AT ATPC MIN POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE
AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4141
PROVISIONING PROVISIONING –– RELAY SETTINGRELAY SETTING
WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARSA: HOUSE KEEPING CONTROL SETTING
B: CLUSTER ALARM OUTPUT SETTING
C: PASOLINK ALARM RELAY ASSIGNMENT FOR PARALLEL ALARM OUTPUT
CLUSTER ALARM INPUT ENABLE / DISABLE
IMPORTANT: FOR CLUSTER ALARM INPUT/OUTPUT, CORRESPONDING CLUSTER ALARM OUTPUT/INPUT IN THE OPPOSITE STATION MUST BE ASSIGNED OR ENABLED.
CLICK ON A BUTTON TO ASSIGN TO RELAYS
IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY ( FROM A OR B OR C)
PASOLINK NEO IDU HAS 6 RELAYS WHICH CAN BE ASSIGNED TO OUTPUT PASOLINK ALARMS, CLUSTER ALARM OUTPUT AND HOUSEKEEPING ALARMS.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4242
PROVISIONING PROVISIONING –– TCN THRESHOLD SETTINGTCN THRESHOLD SETTING
TCN THRESHOLD (15MIN): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION
TCN THRESHOLD (1 DAY): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION
TCN THRESHOLD (15 MIN)
TCN THRESHOLD (1 DAY)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4343
PROVISIONING PROVISIONING –– PMON SELECTPMON SELECT
RX LEVEL TCN THRESHOLD: ENTER THE RX LEVEL THRESHOLD FOR TCN ALARM. No.1 or 2 FOR (1+1) CONFIGURATION
SES ACTIVATION CONDITION: SELECT THE APPROPRIATE RADIO BUTTON FOR PERCENTAGE OF BLOCKS IN ERROR FOR SES ACTIVATION
PMON SELECT
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4444
PROVISIONING PROVISIONING -- OTHERSOTHERS
XPIC CONDITION LOCAL FAIL: (ONLY FOR XPIC CONFIGURATION) SELECT THE APPROPRIATE RADIO BUTTON .
REF LO>> SELF LO: WHEN REF OSCILLATOR FAILS, USE THE LOCAL OSCILLATOR IN THE ODU. IN THIS CONDITION VERTICAL & HORIZONTAL ODUs ARE NOT SYNCHRONIZED. XPIC OPERATE IRREGULARLY.
MUTE : WHEN REF OSCILLATOR FAILS, MUTE THE TX OUTPUT. XPIC FUNCTION IS NOT USED IN THIS MODE.
OTHERS
EOW2 EXTERNAL SETTTING: THIS SETTING IS FOR BACK TO BACK CONNECTION OF EOW CALLING SIGNAL BETWEEN DIFFERENT TYPES OF PASOLINK EQUIPMENT.
INVERT : SELECT THIS FOR CONNECTION BETWEEN PASOLINK+ / MX IDU & NEO IDU
NORMAL: SELECT THIS FOR CONNECTION BETWEEN PASOLINK IDU & NEO IDU
ALARM CORRELATION CAPABILITY: THIS SETTING IS TO FILTER THE ALARMS AND GIVE THE MAIN (ROOT) CAUSE OF THE ALARM
OFF : CORRELATION OFF GIVES THE MAIN ALARM AS WELL AS THE SECONDARY ALARMS
NORMAL: CORRELATION ON, GIVES MAIN CAUSE OF THE FAILURE
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4545
METERINGMETERING
(1+0) configuration
(1+1) Configuration Hot Standby
+09.0-50.4
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4646
INVENTORYINVENTORY
ODU Information
IDU module Information
IDU module FPGA Information
Modem Version Information
IDU Network Properties
Softkey related information
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4747
AUXILIARY I/OAUXILIARY I/O
INPUT:
Close: Indicate HK ALM inputcondition
Close: Indicate HK control sent out
Shading indicates HK controls are not assigned
Click on the arrow and select Open or Close to send a Control signal and click the SET Button
Inputs 3, 4, 5 and 6 are common to HK alarm input and Cluster alarm input. When Cluster alarms are enabled in Provisioning it cannot be used for HK ALM Input
OUTPUT:
Outputs 1, 2, 3 and 4 are common to both HK Controls and Cluster Alarm outputs. Only one type should be assigned to each output.
CLICK “SET” TO SEND SELECTED CONTROL SIGNAL
HOUSE KEEPING ALM INPUT CAN BE MONITORED ONLY FROM LCT.PNMx
CLUSTER ALM INPUTS CAN BE TAKEN OUT FROM THE OPPOSITE STATION CLUSTER ALM OUT RELAY.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4848
MAINTENANCE 1 & 2 MAINTENANCE 1 & 2
SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON
MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.
MAINTENANCE 1 , HAS TWO SECTIONS ONLINE AND OFFLINE. OFFLINE MAINTENANCE ITEMS MAY CAUSE INTERRUPTION IN THE RADIO LINK
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 4949
MAINTENANCE 1 & 2 (SDH)MAINTENANCE 1 & 2 (SDH)
SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON
MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5050
MAINTENANCE 1 (COMMON) MAINTENANCE 1 (COMMON)
TX SW MANUAL CONTROL
THIS CONTROL APPLIES TO (1+1) HOT STANDBY CONFIGURATION.
SELECT THE CH# TO SWITCH TO OR KEEP (CH1 OR CH2) AND CLICK THE SET BUTTON TO SWITCH TO THE SELECTED TX CHANNEL
TO NORMALIZE THE MAINT CONTROL SELECT AUTO AND CLICK THE SET BUTTON
AFTER EACH MAINTENANCE CONTROL SELECTION CLICK ON THE “SET” BUTTON TO IMPLEMENT THE MAINTENANCE CONTROL. THE CHANGED STATUS IS SHOWN UNDER THE “VALUE” COLUMN HIGHLIGHTED IN YELLOW
MAINT MODE CONTROL
SELECT ON AND CLICK SET BUTTON FOR MAINTENANCE MODE
SELECT OFF AND CLICK SET BUTTON TO NORMALIZE MAINTENANCE MODE
BEFORE EXISTING THE MAINTENANCE MODE NORMALIZE ALL MAINT CONTROL ITEMS (ITEMS IN YELLOW IN THE VALUE COLUMN)
RX SW MAINTENANCE MODE
THIS IS SET FROM THE PROVISIONING UNDER “CONDITIONS FOR TX/RX SW” MENU
“MANUAL” MEANS IT IS ONLY POSSIBLE TO SW TO A RX CH THAT IS NORMAL
“FORCED MANUAL” MEANS IT IS POSSIBLE TO SW TO A RX CH EVEN IF IT IS IN ALARM CONDITION
RX SW MANUAL CONTROL
SELECT THE CH TO SWITCH TO OR KEEP (CH1 OR CH2) AND CLICK THE SET BUTTON TO SWITCH TO THE SELECTED RX CHANNEL
TO NORMALIZE THE MAINT CONTROL SELECT AUTO AND CLICK THE SET BUTTON
1234
1
2
4
3
THIS CONTROL MOMENTARILY INTERRUPT THE RADIO LINK
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5151
MAINTENANCE 1 (COMMON) MAINTENANCE 1 (COMMON)
CW CONTROL
THIS CONTROL IS USED TO TRANSMIT AN UN-MODULATED CARRIER FOR MEASUREMENT PURPOSE.SELECT ON AND CLICK THE SET BUTTON TO TRANSMIT AN UN-MODULATED CARRIER
SELECT THE LAN PORT TO BE RESET FROM THE DROP DOWN MENU, AND CLICK THE SET BUTTON
TX MUTE CONTROL
THIS MAINT ITEM SET THE SELECTED ODU’S RF OUTPUT POWER CONTROL TO OFF MODE AND OVERWRITE SWITCHING LOGIC CONTROL COMMAND. SELECT ON AND CLICK SET BUTTON TO CUT THE RF OUTPUT POWER OFF (MUTE ON) THE ODU
LAN DEVICE RESET
THIS CONTROL IS USED TO GIVE AN IF LOOP BACK AT THE OUTPUT OF THE MODEM WITHIN THE IDU
IN THE CASE OF (1+1) CONFIGURATION MAKE SURE THAT THE IF LOOP BACK IS GIVEN ON THE CH THAT IS RECEIVING. DURING IF LOOP BACK THE ODU RF OUTPUT IS MUTED.
THIS CONTROL IS USED TO RESET THE LAN PORT
IF LOOP BACK CONTROL
1
2
3
BEFORE APPLYING THIS CONTROL CHECK THE TX STATUS LED ON THE FRONT PANEL OF THE IDU TO IDENTIFY THE ONLINE CH.SELECT OFF AND CLICK SET BUTTON TO RESTORE THE RF OUTPUT OFF CONTROL TO THE SWITCHING LOGIC CONTROL
SELECT OFF AND CLICK THE SET BUTTON TO NORMALIZE THIS MAINT CONTROL
4
SELECT ON AND CLICK THE SET BUTTON TO GIVE THE IF LOOP BACKSELECT OFF AND CLICK THE SET BUTTON TO GIVE THE NORMALIZE THE IF LOOP BACK
1
2
3
4
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5252
MAINTENANCE 1 (BB LOOP BACK MAINTENANCE 1 (BB LOOP BACK -- PDH) PDH)
MAIN CH LOOP BACK (NEAR END)
THIS CONTROL IS USED TO GIVE BB LOOP BACK FROM THE INTFC CARD ON SELECTED E1 CHANNELS TOWARDS THE MUX DIRECTION.
1
2
TO GIVE A NEAR END LOOP BACK, SELECT THE E1 CHANNELS BY CLICKING THE ON RADIO BUTTONS AND CLICK THE EXECUTE BUTTON
TO RELEASE THE LOOPBACK CONTROL, SELECT OFFRADIO BUTTON ON EACH CHANNEL AND CLICK THE EXECUTE BUTTON
SELECT ON OR OFF AND CLICK SET BUTTON TO SET ON OR OFF ON ALL E1 CHANNELS. CLICK EXECUTE TO CARRY OUT THE SELECTED LOOPBACK CONTROL.
ALL SETTING
MAIN CH LOOP BACK (FAR END)
THIS CONTROL IS USED TO GIVE FAR END BB LOOP BACK FROM THE INTFC CARD ON SELECTED E1 CHANNELS FROM THE OPPOSITE STATION TOWARDS THE RADIO.TO GIVE A FAR END LOOP BACK, ON THE REQUIRED E1 CHANNELS SELECT THE ON RADIO BUTTON AND CLICK THE EXECUTE BUTTON
TO RELEASE THE LOOPBACK CONTROL, SELECT OFFON EACH CHANNEL AND CLICK THE EXECUTE BUTTON
SELECT ON OR OFF AND CLICK SET BUTTON TO SET ON OR OFF ON ALL E1 CHANNELS. CLICK EXECUTE TO CARRY OUT THE SELECTED LOOPBACK CONTROL.
ALL SETTING
1
2
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5353
MAINTENANCE 1 (OFFLINE) MAINTENANCE 1 (OFFLINE)
IN (1+1) CONFIGURATION, CH1 AND CH2 RX PATH DELAY AT THE INPUT OF THE SWITCH MAY NOT BE EQUAL. AUTOMATIC DADE ADJUSTMENT INSERT ADDITIONAL DELAY IN ONE CH TO MAKE THEM IN PHASE FOR THE HITLESS SWITCH TO OPERATE PROPERLY.
DADE ADJUST
1
2
3
DADE SELECT DADE AND CLICK SET TO MEMORIZE THE DELAY SETTING ADJUSTED UNDER AUTO DADE. THIS DELAY IS ADJUSTED ONLY IN THE STANDBY PATH.
OFFSET DADE SELECT OFFSET DADE AND CLICK SET TO REDUCE THE ABSOLUTE DELAY BETWEEN THE TWO RX CHANNELS. THIS ADJUSTMENT MAY INTERRUPT THE RADIO LINK.
DADE OFF SELECT DADE OFF AND CLICK SET WHEN DADE ADJUSTMENT IS NOT REQUIRED.
NEO ODU CAN CHANGE THE FREQUENCY SUB BAND BY CHANGING THE TX/RX RF BPF. AFTER CHANGING THE SUBBAND FILTER NEW SUB BAND LETTER USED SHOULD BE SET IN THE ODU USING THIS OFFLINE CONTROL. IF YOU CHANGE THIS PARAMETER WITHOUT CHANGING THE SUB BAND FILTER RADIO LINK MAY FAIL.
RF SUB BAND SELECT
SELECT FROM THE DROP DOWN LIST THE SUB BAND LETTER TO BE USED AND CLICK THE SET BUTTON
DURING ANTENNA POINTING ADJUSTMENT, IT IS POSSIBLE TO MONITOR THE RX AGC VOLTAGE FROM THE ODU RX LEV MONITOR POINT IN THE ODU BY CONNECTING A VOLTMETER. TO ACCURATELY MEASURE THIS VOLTAGE SET THIS PARAMETER TO ON.
ANTENNA ALIGNMENT MODE
1
2
3
SET ANTENNA ALIGNMENT MODE TO ON AND CLICK THE SET BUTTON
TAKE CARE TO SET ANTENNA ALIGNMENT MODE TO OFF AND CLICK THE SET BUTTON AFTER THE ANTENNA ALIGNMENT IS OVER
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5454
MAINTENANCE MAINTENANCE -- 22
To change the password
Enter the old password
Enter the new password
Re-Enter the new password for confirmation
Click Execute to change the password
Click Close to exit the change password window
Clear PMON data
This maintenance control clear the Performance Data from the IDU memory.
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5555
MAINTENANCE MAINTENANCE -- 22
SELECT CTRL TO RESET THE CTRL MODULE. MOMENTARILY AFFECT THE NETWORK MONITORING
SELECT ODU NO.1 OR NO.2 TO RESET THE SELECTED ODU CPU. AFFECT THE RADIO LINK FROM THAT ODU
SELECT WITH ROM (PROGRAM) SWITCHING, ONLY AFTER A CTRL PROGRAM OR ODU PROGRAM DOWNLOAD
AFTER SELECTING THE MODULE FOR RESET CLICK THE EXECUTE BUTTON
CLICK CLOSE TO CLOSE THE CPU RESET CONTROL WINDOW
CLICK ON THE CPU RESET BUTTON TO OPEN CPU RESET CONTROL WINDOW
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5656
MAINTENANCE MAINTENANCE -- 22
When NEO network is designed using the NetConfigToolj software, two config files for each NE are created. The “Download Configuration File” menu is used to download these config files.
Select the Configuration File Type to down load
CLICK CLOSE TO CLOSE THE DOWNLOAD CONFIGURATION WINDOW
CLICK ON THE CONFIGURATION FILE TO OPEN THE DOWNLOAD CONFIGURATION CONTROL WINDOW
Repeat the above steps for the second config file
Click Browse and select the path to the file selected in the file type.
Click Execute button to down load the file
Click the Update button to update the configuration
1
2
3
4
5
Update operation reset the CTRL & disconnect the LCT
Select the Configuration File Type to UPLOAD to PC
Repeat the above steps for the second config file
Enter or Click Browse and select the location where the selected file to be uploaded
Click Execute button to up load the file
1
2
3
4
Upload Configuration file menu is used to upload the configuration files in the IDU and save them in the PC
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5757
MAINTENANCE MAINTENANCE -- 22
THIS MENU ITEM IS USED TO DOWNLOAD PROGRAM FILES TO THE IDU AND ODU.
To download CTRL Program select CTRL radio button and Main or Boot depending on the type of CTRL File to be downloaded.
CLICK ON THE PROGRAM FILE BUTTON TO OPEN PROGRAM FILE DOWNLOAD CONTROL WINDOW
To download ODU Program select ODU radio button and No.1 or No.2 ODU.
Select FPGA radio button, and the module that needs FPGA update..
Select Package Program radio button Program when multiple program modules need to be downloaded
Select the Download program type and module1
Enter the location of the program file or click “Browser” and select the file.
2
Click on the Execute button to down load the program file.3
After completing the down load click on the “CPU Reset” button4
Select the module to reset. Tick the “with ROM Program Switching”box and click on the Execute button
5
This control may affect the radio link connection
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5858
MAINTENANCE MAINTENANCE -- 22
CLICK THE EQUIPMENT CONFIG FILE BUTTON IN THE UPLOAD SECTION TO OPEN THE UPLOAD EQUIPMENT CONTROL WINDOW
CLICK ON THE DOWNLOAD EQUIPMENT CONFIG FILE BUTTON TO OPEN DOWNLOAD EQUIPMENT CONTROL WINDOW
CLICK ON THE UPLOAD EQUIPMENT CONFIG FILE BUTTON TO OPEN UPLOAD EQUIPMENT CONTROL WINDOW
1
ENTER OR BROWSE TO THE LOCATION THE FILE IS TO BE UPLOADED AND ENTER THE FILE NAME
2
CLICK ON THE EXECUTE BUTTON TO UPLOAD 3
CLICK THE EQUIPMENT CONFIG FILE BUTTON IN THE DOWNLOAD SECTION TO OPEN THE DOWNLOAD EQUIPMENT CONTROL WINDOW
1
ENTER OR BROWSE TO THE LOCATION THE FILE TO BE DOWNLOADED AND SELECT THE FILE NAME2
CLICK ON THE EXECUTE BUTTON TO DOWNLOAD 3
AFTER THE DOWN LOAD IS OVER CLICK THE UPDATE BUTTON TO UPDATE THE EQUIPMENT CONFIGURATION
4
NEO IDU EQUIPMENT CONFIGURATION CAN BE SAVED (UPLOADED) TO A PC USING THE UPLOAD CONFIGURATION FILE MENU. WHEN THE IDU OR THE CTRL MODULE IS FAULTY AND IS REPLACED BY A SPARE, DOWN LOAD THE SAVED EQUIPMENT CONFIGURATION FILE , USING THE DOWN LOAD MENU
CLICK THE CLOSE BUTTON TO EXIT THE CONTROL WINDOW
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 5959
MAINTENANCE MAINTENANCE -- 22
DATE AND TIME OF THE NE CAN BE SET LOCALLY FROM THIS MENU ITEM
CLICK DATE/TIME SETTING BUTTON TO OPEN THE DATE/TIME SETTING WINDOW. THE DATE AND TIME FIELDS SHOW THE CURRENT IDU SETTING.
CLICK THE DATE/TIME SETTING BUTTON TO OPEN THE DATE/TIME SETTING CONTROL WINDOW
ENTER THE DATE AND TIME IN THE RESPECTIVE FIELDS AND CLICK EXECUTE TO CHANGE THE IDU DATE/TIME SETTING.
SET THE DISPLAY PC TIME CHECK BOX AND CLICK THE EXECUTE TO SHOW THE PC DATE AND TIME. CLICK EXECUTE AGAIN TO CHANGE THE IDU DATE/TIME SETTING TO THE PC DATE/TIME.
OR
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6060
PERFORMANCE MONITOR PERFORMANCE MONITOR -- HISTORYHISTORY
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6262
ALARM TABLEALARM TABLEALM ITEM DESCRIPTION ALM ITEM DESCRIPTION
ODU SDH INTFCODU ALM ODU TOTAL ALARM UNEQUIPPED SDH INTFC NOT MOUNTEDTX PWR ALM ODU OUT POWER DECREASED TYPEMISMATCH MOUNTED INTFC DIFFERENT FROM CONFIGURED
TX INPUT ALM TX IF INPUT LEVEL DECREASED MODULE ALM INTFC UNIT FAILUREAPC ALM ODU LOCAL OSCCILATOR UNLOCKED LOS (MUX) LOSS OF STM-1 SIGNAL FROM MUXODU CPU/CBL OPN ALM ODU CPU FAILURE OR IF CABLE OPEN LOF (MUX) LOSS OF STM-1 FRAME FROM MUXRX LEV ALM ODU RECEIVED RF LEVEL LOW E-BER (MUX) EXCESSIVE BER DETECTED FROM MUXLO REF ALM REFERENCE LO SIGNAL IS LOST E-BER (DMR) EXCESSIVE BER DETECTED FROM RADIO DIRECTION
MODEM SD (MUX) SIGNAL DEGRADE DETECTGED FROM MUXUN EQUIPPED MODEM UNIT NOT MOUNTED LOS (DMR) LOSS OF STM-1 SIGNAL DETECTED FROM RADIOMODULE ALM MODEM UNIT AILURE LOF (DMR) LOSS OF STM-1 FRAME DETECTED FROM RADIOLOF LOSS OF RADIO FRAME SYNCHRONZATION IN MODEM SD (DMR) SIGNAL DGRADE DETECTED FROM RADIOFRAME ID FRAME ID MISMATCH TF ALM TX FAIL ; NO STM-1 OUT PUT TO MUX HIGH BER HIGH BER LEVEL DETECTED IN MODEM UAE (MUX) UNAVAILABLE COMDITION FROM MUX EXISTSLOW BER LOW BER LEVEL DETECTED IN MODEM UAE (DMR) UNAVAILABLE CONDITION FROM RADIO EXISTSEARLY WARNING EARLY WARNING CONDITION DETECTED IN CH # APS SW FAIL APS SW FAILUREMOD ALM MODEM PLL UNLOCK, OUTPUT DOWN, CLOCK LOSS OUTPUT CONTROL STM-1 OUTPUT CONTROL APPLIED (MS-AIS GENERATION)DEM ALM CARRIER / FRAME ASYNCH AT MODEMINPUT VOLTAGE INPUT DC VOLTAGE HIGH OR LOW XPICPOWERSUPPLY POWER SUPPLY FAILURE (1+1) ONLY XCTRL ALM XPIC CONTROL FAILUREIF CABLE SHORT IF CABLE CONNECTED TO ODU IS SHORT CIRCUIT X IF ALM XIF SIGNAL IS LOW OR LOSTCABLE EQUALIZER CABLE EQUALIZER CONTROL IS LOST IN MODEM XREF ALM XPIC REF FREQUENCY IS LOSTLINEARIZER BB LNZ CONTROL IS LOST WS
PDH INTFC WS CH INPUT LOSS LOSS OF WS CH # INPUT SIGNALUNEQUIPPED INTFC NOT MOUNTED WS AIS RCVD AIS RECEIVED ON WS CH #, FROM MUX TYPE MISMATCH MOUNTED INTFC DIFFERENT FROM CONFIGURED WS AIS GENERATED AIS IS GENERATED IN WS CH#MODULE ALM INTFC HARDWARE FAILURE WS CH USAGE ERROR WS SIGNAL DETECTED IN NOT USED WS CHINPUT LOSS CH # LOSS OF INPUT SIGNAL CH# FROM MUX ( E1 OR E3) LANAIS RCVD CH # AIS RECEIVED FROM CH # FROM MUX (E1 OR E3) LAN LINK LAN LINK FAILUREAIS GENERATED CH # AIS GENERATED ON CH # (E1 OR E3) LAN COLLISION COLLISION OCCURRED IN LAN CH USAGE ERROR CH# E1 SIGNAL DETECTED IN CH SET TO NOT USED LINK LOSS FORWARDING REMOTE LAN LINK FAILURE DETECTEDUAE UN AVAILABLE CONDITION FROM RADIO EXISTS
CTRL ALM CONTROL UNIT TOTAL ALARM
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6363
2 PORT LAN INTFC (SDH)2 PORT LAN INTFC (SDH)
WS /SC LAN INTFC (SDH)WS /SC LAN INTFC (SDH)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6464
2 2 –– PORT LAN INTFC (SDH) PORT LAN INTFC (SDH) –– EQUIPMENT SETUPEQUIPMENT SETUP
In User Interface Select SDH 2 Port LAN over STM-1 from the drop down list
In LAN Capacity (MAIN) , 150 Mbps
In INTFC MAIN (Work) Select 2 Port LAN over STM-1 from the drop down list
In LAN Port Usage (MAIN) select :
1
2
3
4
P1 =75MB / P2 =75 MB (Default)
P1 =100MB / P2 =50 MB
P1 =100MB / P2 =Not used
Best Effort
Click SET button in the Common section5
1
2
34
5
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6565
2 2 –– PORT LAN INTFC (SDH) PROVISIONINGPORT LAN INTFC (SDH) PROVISIONING
In the LCT MENU, select Provisioning and from the expanded menu select LAN Port Setting
In INTFC (MAIN) Setting, select the clock source used by the LAN Port
In PORT 1 & PORT 2 Setting select:
1
2
3
Port Usage: select whether selected LAN Port is used or not used
1
3
4
Internal ClockDMR >>Internal Clock (use DMR clock if it fails use Internal clock)
Speed & Duplex: Set this according to the external equipment port setting
Flow Control: Select Flow control ON or OFF
Collision Report: In Half Duplex mode, Select whether to consider collision condition as an alarm event . Select Report or Not ReportLink Loss Forwarding: Select whether to enable or disable Link Loss Forwarding
4 After finishing the LAN Port Setting , click on the SET button in the common section
2
Auto
Neg
otia
tion
10 B
ase-
T /H
alf D
uple
x
10 B
ase-
T /F
ull D
uple
x
100
Base
-TX
/Hal
f Dup
lex
100
Base
-TX
/Ful
l Dup
lex
10 B
ase-
T /H
alf (
Fix)
100
Base
-TX
/Hal
f (Fi
x)
Auto Negotiation (Auto MD/MDI-X)
10 Base-T /Half Duplex (MDI/MDI-X)
10 Base-T /Full Duplex (MDI/MDI-X)
100 Base-T /Half Duplex (MDI/MDI-X)
100 Base-T /Full Duplex (MDI/MDI-X)
IDU PORT SETTING
EXTERNAL EQUIPMENT
MDI/MDI-X is selected according to the cable type or terminal type to be used (Straight or Cross Type)
Link Loss Forwarding
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6666
2 2 –– PORT LAN INTFC (SDH) PORT LAN INTFC (SDH) -- ALARM & STATUSALARM & STATUS
In the LCT MENU, select ALARM & STATUS
In INTFC MAIN (1) area the summary alarms & status information for the 2 Port LAN card is displayed. To see details for each port click on any alarm or status item for LAN Port., separate detailed port information window open
1
2
Normal Normal Normal
ALARMS & STATUS Information for the 2 Port LAN Card depends on the Port configuration in Provisioning
Click on the Alarm/Status area to see details for each Port
Grayed status means alarm/status item is selected Not Report
LLF- Link Loss Forwarding
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6767
WS / LAN INTFC (SDH) WS / LAN INTFC (SDH) –– EQUIPMENT SETUPEQUIPMENT SETUP
In User Interface Select SDH STM-1 from the drop down list
In LAN Port Usage (Sub) , Select: P1- 2 shared / 1 Port Only (WS)
In INTFC (Work) Select STM-1 Optical, STM-1 Electrical or GbE over STM-1 from the drop down list
In INTFC (PROT) Select
1
2
3
4
WS / LANSTM-1 Optical
WS
Not used
Click SET button in the Common section5
5
1
2
3
4
P1 -2 Shared /1 Port only (SC)
In LAN Capacity (SUB) select: 2MB if Port usage selected is P1-2 Shared /1 Port Only (WS)5
64KB/128KB/192KB or 256KB if P1-2 Shared/ 1 Port Only (SC)
Capacity RFCOH RSOH WS
64 Kbps SC 1 E1 or F1
128 Kbps SC 1 and 2
192 Kbps DCCr
256 Kbps SC 1 to 4
2 Mbps WS
5
SC, RSOH Bytes and WS can be selected for LAN capacity selection
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6868
WS/LAN INTFC (SDH) PROVISIONINGWS/LAN INTFC (SDH) PROVISIONING
In the LCT MENU, select Provisioning and from the expanded menu select LAN Port Setting
In INTFC (SUB) Setting, select Switching Function Enabled or Disabled
In PORT 1 & PORT 2 Setting select:
1
2
3
Port Usage: select whether selected LAN Port is Used or Not used
1
3
4
Speed & Duplex: Set this according to the external equipment port setting
Flow Control: Select Flow control ON or OFF
Collision Report: In Half Duplex mode, Select whether to consider collision condition as an alarm event . Select Report or Not ReportLink Loss Forwarding: Select whether to enable or disable Link Loss Forwarding
4 After finishing the LAN Port Setting , click on the SET button in the common section
2
Auto
Neg
otia
tion
10 B
ase-
T /H
alf D
uple
x
10 B
ase-
T /F
ull D
uple
x
100
Base
-TX
/Hal
f Dup
lex
100
Base
-TX
/Ful
l Dup
lex
10 B
ase-
T /H
alf (
Fix)
100
Base
-TX
/Hal
f (Fi
x)
Auto Negotiation (Auto MD/MDI-X)
10 Base-T /Half Duplex (MDI/MDI-X)
10 Base-T /Full Duplex (MDI/MDI-X)
100 Base-T /Half Duplex (MDI/MDI-X)
100 Base-T /Full Duplex (MDI/MDI-X)
IDU PORT SETTING
EXTERNAL EQUIPMENT
MDI/MDI-X is selected according to the cable type or terminal type to be used (Straight or Cross Type)
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 6969
WS/LAN INTFC (SDH) WS/LAN INTFC (SDH) -- ALARM & STATUSALARM & STATUS
In the LCT MENU, select ALARM & STATUS
In INTFC Sub (2) area the summary alarms & status information for the WS / LANINTFC card is displayed. To see details for each port click on any alarm or status item for WS/LAN INTFC, separate detailed Sub Port information window open
1
2
ALARMS & STATUS Information for the 2 Port LAN Card depends on the Port configuration in Provisioning
Click on the Alarm/Status area to see details for each Port
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 7070
Control Card Replacement ( Using Memory Card)Control Card Replacement ( Using Memory Card)
Insert MMC Card to IDU Card Slot
Starts to Backup IDU Equipment Configuration
Set Protect SW to ON(Upper Position)
Parameter Backup Completed
Remove Control Card
MAINT
MEMORY
IDU
SD / MMCCard Slot
PROTECT SW
MAINT LED Starts to Blink slowly. MEM Off
Mount NEW Control CardBefore mounting the spare Control Card, set Protect SW to ON position
MAINT LED Starts to Blink
Insert Memory Card with Equip Config data to NEW Control Card
Slot. MEM LED Blinks fast
MAINT LED Stop Blinking (Steady ON)
Yes
Yes
YesSet Protect SW to OFF
Remove MMC
Equipment Configuration data Restored
MAINT LED lights,MEM LED blink fast for few
seconds
Control Card should be removed with the protection SW in ON position
Remove MMC card
NoNo
Each time NEO equipment configuration is changed please take a back up to a MMC card. The back up can be used to restore the equipment configuration during CTRL module replacement
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 7171
Connect LCT
Set IDU to MAINT
Put PROT SW to ON & Remove Control Card
MAINT
MEMORY
IDU
PROTECT SW
Mount NEW Control Card Before mounting Control Card, set Protect SW to ON position
MAINT LED Starts to Blink
Connect LCT and Download Equipment Config File
Download completed
Yes
Yes
Execute Update from LCT
MAINT LED Steady ON
Upload Equip. Config file using LCT Menu
Equipment Configuration data Restored
Set Protect SW to OFF
Yes
Control Card Replacement ( Using LCT)Control Card Replacement ( Using LCT)
Each time NEO equipment configuration is changed please take a back up. The back up can be used to restore the equipment configuration during CTRL module replacement
TOPC-E4011E-02-07413 PASOLINK NEO LCT PASOLINK NEO LCT 7272
Thank youThank you
This training document describes the current version of the equipment.The specifications or configuration contained in this document are subject to change without notice.