PASOLINK NEO LCT PASOLINK NEO LCT 11TOPC-E4011E-01-xxxxxx

LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE

COMMUNICATION BETWEEN THE LCT AND THE PASOLINK NEO IS VIA THE LCT PORT OF THE CTRL MODULE.THE LCT AND THE CTRL MODULE MOUNTED ON THE PASOLINK NEO MUST BE CONNECTED USING A USB A-B TYPE CABLE. TYPE-B CONNECTS TO THE LCT PORT.

LCT PC SPECIFICATION

CPU PENTIUM-M 1.6GHz OR BETTER

RAM 512MB OR MORE

HDD 100 MB OR MORE FREE CAPACITY

DISPLAY COLOR LCD (1024x768)

CD ROM DRIVE/USB-PORT / USB CABLE WITH USB-B CONNECTOR

JAVA RUNTIME ENVIRONMENT V1.5.0_05 OR HIGHER

LCT WEB SOFTWARE (VER 2.XX.XX)

IE 6 WITH SP2 PR HIGHER

WINDOWS 2000 (ENGLISH) WITH SP4 OR HIGHERWIN DOWS XP PROFESSIONAL (ENGLISH) SP2

OS

SOFTWARE REQUIREMENT

(Open Application on LCT)INCOMPATIBLEPlease change LCT

CTRL: 3.xx.xx

(Open Browser and input URL)(Open Browser and input URL)CTRL: 2.xx.xx

LCT: 2.xx.xxLCT: 1.xx.xx

IDU AND LCT COMPATIBILITY

There are two types of LCT version corresponding to the IDU F/W version installed. LCT WEB applet Version 1.(Rev 1.xx.xx) is installed in the IDU and the LCT WEB Version (Rev 2.xx.xx) is installed in the PC.

Page 3: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 22TOPC-E4011E-01-xxxxxx

LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE

MAKE THE LCT DIALUP CONNECTION

OPEN THE IE BROWSER AND ENTER THE URL

LOGIN: Admin AND ENTER PASSWORD

INSTALL USB MODEM DRIVER (NEC)INSTALL JAVA 2 RUN TIMECREATE A DIAL UP CONNECTION NAMED LCT

1

3

DEFAULT PASSWORD: 12345678

2

For LCT Ver. 1.xx.xx & CTRL Ver. 2.xx.xx

Http://172.17.254.253INSTALL FROM THE LCT WEB SETUP FILES CD,

JAVA RUN TIME

USB DRIVER

Page 4: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 33TOPC-E4011E-01-xxxxxx

LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACE

MAKE THE LCT DIALUP CONNECTION

START THE LCT FOR STDLOGIN: Admin AND ENTER PASSWORD

INSTALL USB MODEM DRIVER (NEC)

INSTALL JAVA 2 RUN TIMECREATE A DIAL UP CONNECTION NAMED LCT

1

3

DEFAULT PASSWORD: 12345678

INSTALL THE LCT WEB IN THE PC2

For LCT Ver. 2.xx.xx & CTRL Ver. 3.xx.xx

INSTALL FROM THE LCT WEB SETUP FILES CD,

JAVA RUN TIME *

USB DRIVER

LCT-WEB APPLET

* In later versions Java Run Time will be included in the LCT WEB Applet

Page 5: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 44TOPC-E4011E-01-xxxxxx

LCT LOGINLCT LOGIN

ENTER THE USER NAME “Admin” AND PASSWORD

(DEFAULT PASSWORD IS”12345678”

CLICK THE “LOGIN”

LCT WEB OPENS TO ALARM/STATUS WINDOW

1

2

Two User ID’s are defined “Admin” (with Password) and “User” (without PW )

USER ID : AdminWITH PASSWORD, ACCESS LCT FOR MONITOR & CONTROL

USER ID : UserWITHOUT PASSWORD, ACCESS LCT FOR MONITOR ONLY

Page 6: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 55TOPC-E4011E-01-xxxxxx

LCT MENULCT MENU

CH Setting-1

CH Setting-2

BER Threshold Setting

SC Assignment

LAN Port Setting

TX Power Control

Condition for TX/RX SW

Relay Setting

TCN Threshold (15min)TCN Threshold (1day)

PMON Select

Others

User Interface

Redundancy Setting

INTFC (Work)

INTFC (Prot)

XPIC Usage

APS Function

Modulation Scheme

Transmission Capacity

TX RF Frequency[MHz]RX RF Frequency[MHz]

Frame ID

TX Power Control

STM-1 Setting

ALS Function

Condition for APS

LAN Port Usage (Main)

LAN Capacity (Main)

PDH E1 with LANPDH E1

PDH E3 with LANSDH STM-1

1 + 1 (Hot Standby TERM)1 + 0 (TERM)

1 + 1 (Twin Path TERM)

48 x E1 PKG16 x E1 Standard PKG (E/W LAN)

4 Port LAN with E1

4 Port LAN with E1

2 WAY PDH (REP)

STM-1 (Optical)STM-1 (Electrical)1 x E3 +4E1 PKG (E/W LAN)2 x E3 +8E1 PKG (E/W LAN)

E3 Setting

STM-1 (Optical) for APSNot Used

WS / LAN

Used (Main Master)Not Used

Used (SUB Master)

UnavailableAvailable

16QAMQPSK

32QAM128QAM

10 [MB]20 [MB]40 [MB]80 [MB]80 [MB]100 [MB]156 [MB]

Frame ID 1 - 32

ATPCMTPC

NOT USEDP1-2 Shared/1 Port Only(Main)P1-2 Shared/1 Port Only(SC)P1-2 Separated(Main)

CH # LAN ( Status)CH #

CH Usage Error Report

AIS Activation Condition

AIS Generation ReportAIS Received ReportAIS Received Condition

E1 Port Impedance (CH#)

High BER ThresholdLow BER ThresholdE-BER (DMR)SD (DMR)E-BER (MUX)SD (MUX)

ATPC Trehsold Level [dBm]Additional ATT [dB]ATPC Range [MAX] [dB]ATPC Range [MIN] [dB]ATPC Power Mode

ATPC Trehsold Level [dBm]Additional ATT [dB]

MTPC TX Power [dB]

MS - AIS Generation

ALS FunctionALS Interval

TX SW Priority

RX SW PriorityRX SW Maintenance Mode

RX SW Condition Early Warning

APS Maintenance ModeAPS Condition-SF(PROT)APS Condition-SD (B1)

Lock in Count (times)Lock in Usage

Lock in Detect Time (mins)Lock in Hold Time (mins)

HK OUT 1 to 4 setting

CLUSTER ALM OUT 1 to 4 settingPASOLINK ALM OUT settingCLUSTER ALM IN 1 to 4 setting

RX Level TCN Threshold [dBm]SES Activation

EOW2 Wxternal SettingAlarm Correlation Capability

Switching Function2M Frame

Port UsageSpeed & DuplexFlow ControlCollision ReportLink Loss Forwarding

LAN PORT SETTING

Por

t 1 P

ort 2

RX SW Manual ControlTX SW Manual ControlTX Mute ControlCW ControlAPS Manual Control

DADE Adjust

Linearizer Control

XPIC Control

RF SettingAntenna Alignment Mode

Main Loopback(Near End)IF Loopback

Main Loopback(Far End)

ALS Restart

Maintenance

OFFLine Maintenance

Download Configuration File

Password SettingDate / Time Setting

PMON Clear

CPU Reset

Download Program FileDownload Equip Config FileUpload Configuration FileUpload Equip Config File

Maintenance -1

Maintenance -2

ProvisioningEquipment Setup

XPIC Condition - Local Fail REF LO>>Self LONormal InvertOFF OFF

Mute

30% 15%

Disabled Enabled

RL-3RL-4RL-5RL-6

Manual ForcedPriority High Priority LowInclude SD Exclude SDUsed Notused

Include EW Exclude EWManual Forced

Non Priority Priority No.1

Hold Max Min

Disabled180Sec 300Sec60Sec

Enabled

Disabled Enabled

Disabled EnabledReport Not ReportON OFF

Used Not Used

Disabled Enabled

120 Ohms 75 OhmsLOF+HBER LOFAlarm Status

Report Not Report

Used Not Used

Page 7: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 66TOPC-E4011E-01-xxxxxx

LCT WINDOWLCT WINDOW

MAIN DISPLAY AREA

SUMMARY ALARM STATUS AREAPROGRESS AREA

MENU AREA

COMMON AREA

DISPLAY THE MAIN LCT MENU AND EXPANDED MENUS FOR PROVISIONING, MAINTENANCE AND PMON

COMMON AREA DISPLAY COMMON CONTROL BUTTONS SET, LOGOUT, RELOAD.

DISPLAY THE RESULTS OF THE SET CONTROLS: “OK’ OR “NG”

DISPLAY THE SUMMARY ALARMS OF NEO MAIN UNITS AND MAINTENANCE STATUS

DISPLAY THE LOGIN NAME AND SOFTWARE VER.

DISPLAY THE DETAILS OR CONTROL ITEMS OF THE SELECTED LCT MENU ITEM

Page 8: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 77TOPC-E4011E-01-xxxxxx

ALARM & STATUS ALARM & STATUS --PDHPDH

Modem Detail

ODU Detail

Interface Detail PMON Detail

CTRL Detail

Alarm/Status Color Code

Page 9: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 88TOPC-E4011E-01-xxxxxx

ALARM & STATUS ALARM & STATUS --SDHSDH

Modem Detail

ODU Detail

Interface Detail

PMON Detail

CTRL Detail

Alarm/Status Color Code

Page 10: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 99TOPC-E4011E-01-xxxxxx

ALARM & STATUS ALARM & STATUS --SDHSDH

Modem Detail

ODU Detail

Main/Sub Interface Detail

PMON Detail

CTRL Detail

Unavailability status

Page 11: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1010TOPC-E4011E-01-xxxxxx

EQUIPMENT SETUPEQUIPMENT SETUP

WHEN SDH INTFC IS SELECTED

AFTER SELECTING ALL THE CONFIGURATION SETTINGS CLICK THE

SET BUTTON TO IMPLEMENT THE

SETTING

WHEN PDH INTFC IS SELECTED

Page 12: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1111TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– PDHPDH

WHEN MTPC IS SELECTED IN EQUIPMENT SETUP

WHEN ATPC IS SELECTED IN EQUIPMENT SETUP

Page 13: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1212TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– PDHPDH

Page 14: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1313TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– PDH LAN SETTINGPDH LAN SETTING

WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARS

THIS MENU CONFIGURE THE LAN PORT PARAMETERS WITHIN THE LAN CAPACITY (MAIN) AND LAN PORT USAGE (MAIN) SETTING IN THE EQUIPMENT SETUP

LAN PORT SETTING FOR 16E1 AND 2-PORT LAN INTERFACE CARD

Page 15: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1414TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– SDHSDH

SELECT THE BER THRESHOLD SETTING FOR THE RADIO LINK AND FOR THE STM-1 SIGNAL FROM MUX & RADIO DIRECTIONS.

TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE DIRECTION OF MUX OR RADIO (DMR).

E1 (MUX) E1 (DMR)F1 (DMR)F1 (MUX)

E1 (MUX)F1 (MUX)

DCCr (MUX)V.11

DSC1 TO 4V.11 & RS-232C

DCCr (DMR) DCCr (MUX)

SC LAN DSC1 TO 4

V.11 & RS-232CV.11 & RS-232C

SDH

CLICK ON THE APPROPRIATE RADIO BUTTON TO SELECT THE THRESHOLD SETTING

CLICK ON THE ARROW AND SELECT FROM THE DROP DOWN MENU THE USAGE FOR EACH USER CHANNEL . WHEN V.11 CH IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

Page 16: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1515TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– STMSTM--1 SETTING1 SETTING

MS-AIS GENERATION SETTING IS USED TO STOP SENDING MS-AIS SIGNAL DUE TO RADIO LINK OR EQUIPMENT FAILURE.

WHEN DISABLED:- DURING FAILURE OPTICAL INTFC WILL STOP TRANSMITTING THE OPTICAL SIGNAL, ELECTRICAL INTFC WILL SEND UNFRAMED AIS.

WHEN ENABLED:- SEND MS-AIS DUE TO RADIO LINK OR EQUIPMENT FAILURE.

AUTOMATIC LASER SHUT DOWN (ALS) FUNCTION IS AVAILABLE ONLY FOR OPTICAL INTFC . DURING LOS OF SIGNAL AT THE INPUT OF THE OPTICAL INTFC IT WILL CUT THE LASER OUTPUT FROM THE OUTPUT OF THE OPTICAL INTFC. DURING THIS TIME AT DEFINED INTERVALS INTFC WILL OUTPUT A 2 SEC LASER PULSE.

SELECT ENABLE OR DISABLE FROM THE ALS FUNCTION RADIO BUTTON

IF ENABLE IS SELECTED, SELECT ALS INTERVAL FROM 60, 180, AND 300 SEC .

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

Page 17: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1616TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING -- APSAPS

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

APS CONDITION –SF (PROT) APPLIES WHEN FORCED MANUAL SWITCHOVER TO PROTECTION INTFC IS MADE

PRIORITY HIGH: WHEN SIGNAL FAIL (SF) OCCURS IN THE PROTECTION INTFC, KEEPS THE ONLINE, ON WORK INTFC

PRIORITY LOW: IGNORE THE SIGNAL FAIL CONDITION IN FORCED MANUAL, SWITCHOVER TO PROT INTFC

THIS MENU ITEM APPEARS WHEN APS FUNCTION AVAILABLE, IS SET IN THE SETUP CONFIGURATION. OPTICAL INTFC SHOULD BE MOUNTED IN MAIN & SUB SLOTS

APS MAINTENANCE MODE:

MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED INTFC (ROUTE)

FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED INTFC DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)

APS CONDITION –SD (B1)

INCLUDE SD: SELECT THIS TO CONSIDER STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING

EXCLUDE SD: SELECT THIS TO EXCLUDE STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING

LOCK IN USAGE

USED: WHEN FREQUENT SWITCHING OCCURS BETWEEN WORK & PROT, PAUSE SWITCHOVER UNTIL CONDITIONS SET IN LOCK IN COUNT, LOCK IN DETECT TIME & LOCK IN HOLD TIME ARE MET

NOT USED: ALLOW FREQUENT SWITCH OVER BETWEEN WORK & PROT INTFC.

LOCK IN USAGE SET TO USED

LOCK IN COUNT: NUMBER OF SWITCHOVERS DETECTED WITHIN LOCK IN DETECT TIME TO PAUSE SWITCHOVER ACTION

LOCK IN DETECT TIME: SET THE TIME IN MINUTES. DURING WHICH THE NUMBER OF SWITCHOVER ARE COUNTED FOR LOCK IN FUNCTION

LOCK IN HOLD TIME: SET THE DURATION OF SWITCHOVER PAUSE IN HOURS AFTER LOCK IN IS SET.

Page 18: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1717TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– COMMONCOMMON

RX SW MAINTENANCE MODE:

MANUAL: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, PREVENT SWITCHING TO AN ALARMED CHANNEL (ROUTE)

FORCED: WHEN SWITCHING MANUALLY UNDER MAINTENANCE MODE, FORCIBLY SWITCH TO THE SELECTED CH DISREGARDING IT’S ALARM STATUS ( THIS MAY INTERRUPT TRAFFIC)

RX SW CONDITION EARLY WARNING:

INCLUDE EW: SELECT THIS TO INCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION

EXCLUDE EW: SELECT THIS TO EXCLUDE EW AS A CRITERIA FOR AUTO REDUNDANCY SWITCHING IN (1+1) CONFIGURATION

EARLY WARNING BER SETTING IS 1E-9

TX & RX SW PRIORITY

NON PRIORITY: SELECT THIS FOR NON HOMING SWITCHING.

PRIORITY NO.1: SELECT THIS FOR HOMING SWITCHING. WHEN BOTH CHANNELS ARE NORMAL USE No.1 AS ONLINE. CH NO.1 FAILS SWITCH TO CH NO.2, WHEN CH NO.1 IS NORMALIZED SWITCH BACK TO CH NO.1 AUTOMATICALLY

Page 19: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1818TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– TX POWER CONTROLTX POWER CONTROL

No.1 & No.2 IS INDICATED FOR (1+1) TWIN PATH CONFIGURATION

MTPC MODE:

MPTC TX POWER : ENTER A NEGATIVE VALUE IN dB (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)

ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE

(SET IN 1 dB STEPS)

TX POWER CONTROL - ATPC TX POWER CONTROL - MTPC

ATPC MODE:

ATPC THRESHOLD: ENTER THE RX THRESHOLD VALUE TO BE USED WHEN OPPOSITE STATION IS IN ATPC MODE

ADDITIONAL ATT: 0 TO 5 dB ADDITIONAL ATTENUATION IN 1 DB STEPS ( IN ADDITION TO THE ATPC RANGE) (DEPENDS ON THE MODULATION)

ATPC RANGE (MAX): MAXIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)

ATPC RANGE (MIN): MINIMUM POWER LEVEL UNDER ATPC CONTROL IS DEFINED BY THIS ITEM (AMOUNT OF ATTENUATION FROM THE ODU NOMINAL TX POWER)

ATPC POWER MODE: THIS ITEM DEFINED THE ODU TX POWER SETTING DURING ATPC CONTROL FAILURE

HOLD: TO MAINTAIN THE CURRENT TX POWER AT THE TIME OF ATPC CONTROL FAILURE

SELECT : MAX: TO TRANSMIT AT ATPC MAX POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE

MIN: TO TRANSMIT AT ATPC MIN POWER LEVEL AT THE TIME OF ATPC CONTROL FAILURE

AFTER SETTING THE PROVISIONING ITEMS CLICK THE SET BUTTON TO APPLY THE PROVISIONING SETTING.

Page 20: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 1919TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– RELAY SETTINGRELAY SETTING

WHEN THE LAN CAPACITY IS SET TO 2MB, 2M FRAMING ITEM APPEARSA: HOUSE KEEPING CONTROL SETTING

B: CLUSTER ALARM OUTPUT SETTING

C: PASOLINK ALARM RELAY ASSIGNMENT FOR PARALLEL ALARM OUTPUT

CLUSTER ALARM INPUT ENABLE / DISABLE

IMPORTANT: FOR CLUSTER ALARM INPUT/OUTPUT, CORRESPONDING CLUSTER ALARM OUTPUT/INPUT IN THE OPPOSITE STATION MUST BE ASSIGNED OR ENABLED.

CLICK ON A BUTTON TO ASSIGN TO RELAYS

IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY ( FROM A OR B OR C)

PASOLINK NEO IDU HAS 6 RELAYS WHICH CAN BE ASSIGNED TO OUTPUT PASOLINK ALARMS, CLUSTER ALARM OUTPUT AND HOUSEKEEPING ALARMS.

Page 21: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2020TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– TCN THRESHOLD SETTINGTCN THRESHOLD SETTING

TCN THRESHOLD (15MIN): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION

TCN THRESHOLD (1 DAY): ENTER THE TCN THRESHOLD VALUES FOR ALARM OCCUR AND ALARM RECOVER FOR MUX DIRECTION AND DMR DIRECTION

TCN THRESHOLD (15 MIN)

TCN THRESHOLD (1 DAY)

Page 22: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2121TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING –– PMON SELECTPMON SELECT

RX LEVEL TCN THRESHOLD: ENTER THE RX LEVEL THRESHOLD FOR TCN ALARM. No.1 or 2 FOR (1+1) CONFIGURATION

SES ACTIVATION CONDITION: SELECT THE APPROPRIATE RADIO BUTTON FOR PERCENTAGE OF BLOCKS IN ERROR FOR SES ACTIVATION

PMON SELECT

Page 23: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2222TOPC-E4011E-01-xxxxxx

PROVISIONING PROVISIONING -- OTHERSOTHERS

OTHERS

EOW2 EXTERNAL SETTTING: THIS SETTING IS FOR BACK TO BACK CONNECTION OF EOW CALLING SIGNAL BETWEEN DIFFERENT TYPES OF PASOLINK EQUIPMENT.

INVERT : SELECT THIS FOR CONNECTION BETWEEN PASOLINK+ & MX IDU

NORMAL: SELECT THIS FOR CONNECTION BETWEEN PASOLINK IDU & NEO IDU

ALARM CORRELATION CAPABILITY: THIS SETTING IS TO FILTER THE ALARMS AND GIVE THE MAIN (ROOT) CAUSE OF THE ALARM

OFF : CORRELATION OFF GIVES THE MAIN ALARM AS WELL AS THE SECONDARY ALARMS

NORMAL: CORRELATION ON, GIVES MAIN CAUSE OF THE FAILURE

Page 24: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2323TOPC-E4011E-01-xxxxxx

METERINGMETERING

(1+0) configuration

(1+1) Configuration Hot Standby

+09.0-50.4

Page 25: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2424TOPC-E4011E-01-xxxxxx

INVENTORYINVENTORY

ODU Information

IDU module Information

IDU module FPGA Information

Modem Version Information

IDU Network Properties

Softkey related information

Page 26: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2525TOPC-E4011E-01-xxxxxx

AUXILIARY I/OAUXILIARY I/O

INPUT:

Close: Indicate HK ALM inputcondition

Close: Indicate HK control sent out

Shading indicates HK controls are not assigned

Click on the arrow and select Open or Close to send a Control signal and click the SET Button

Inputs 3, 4, 5 and 6 are common to HK alarm input and Cluster alarm input. When Cluster alarms are enabled in Provisioning it cannot be used for HK ALM Input

OUTPUT:

Outputs 1, 2, 3 and 4 are common to both HK Controls and Cluster Alarm outputs. Only one type should be assigned to each output.

CLICK “SET” TO SEND SELECTED CONTROL SIGNAL

HOUSE KEEPING ALM INPUT CAN BE MONITORED ONLY FROM LCT.PNMx

CLUSTER ALM INPUTS CAN BE TAKEN OUT FROM THE OPPOSITE STATION CLUSTER ALM OUT RELAY.

Page 27: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2626TOPC-E4011E-01-xxxxxx

MAINTENANCE 1 & 2 (PDH)MAINTENANCE 1 & 2 (PDH)

SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON

MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.

MAINTENANCE 1 , HAS TWO SECTIONS ONLINE AND OFFLINE. OFFLINE MAINTENANCE ITEMS MAY CAUSE INTERRUPTION IN THE RADIO LINK

Page 28: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2727TOPC-E4011E-01-xxxxxx

MAINTENANCE 1 & 2 (SDH)MAINTENANCE 1 & 2 (SDH)

SELECT THE MAINTENANCE CONTROL ITEM AND CLICK ON THE CORRESPONDING SET BUTTON

MAINTENANCE CONTROL STATUS IS INDICATED IN THE VALUE COLUMN. YELLOW INDICATES MAINT CONTROL APPLIED.

Page 29: 77637237 2 NEO LCT Training Manual 18 July

PASOLINK NEO LCT PASOLINK NEO LCT 2828TOPC-E4011E-01-xxxxxx

MAINTENANCE MAINTENANCE -- 22

To change the password

Enter the old password

Enter the new password

Re-Enter the new password for confirmation

Click Execute to change the password

Click Close to exit the change password window

Clear PMON data

This maintenance control clear the Performance Data from the IDU memory.

Page 30: 77637237 2 NEO LCT Training Manual 18 July