WEB LCT ALFOplus80 Software application for the management of ALFOplus80 equipment Release 1.2 User manual MN.00286.E - 003

WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

Embed Size (px)

Citation preview

Page 1: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCTALFOplus80

Software application for the management ofALFOplus80 equipment

Release 1.2

User manual

MN.00286.E - 003

Page 2: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

The information contained in this handbook is subject to change without notice.Property of SIAE MICROELETTRONICA. All rights reserved according to the law and according to the inter-national regulations. No part of this document may be reproduced or transmitted in any form or by anymeans, electronic or mechanical, without written permission from SIAE MICROELETTRONICA.Unless otherwise specified, reference to a Company, name, data and address produced on the screen dis-played is purely indicative aiming at illustrating the use of the product.MS-DOS®, MS Windows® are trademarks of Microsoft CorporationHP®, HP OpenView NNM and HP–UX are Hewlett Packard Company registered trademarks.UNIX is a UNIX System Laboratories registered trademark.Oracle® is a Oracle Corporation registered trademark.Mozilla Firefox is a Mozilla Foundation registered trademark.Linux term is a trademark registered by Linus Torvalds, the original author of the Linux operating system.Linux is freely distributed according the GNU General Public License (GPL). Other products cited here in are constructor registered trademarks.

Page 3: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1

WEB LCT ALFOplus80Contents

MANUAL CONTENT ................................................................................................................... 9

WEB LCT APPLICATION.......................................................................................................... 10

FUNCTIONALITIES.............................................................................................................. 11

LIMITS.............................................................................................................................. 12

INSTALLATION................................................................................................................... 13

WEB LOCAL CRAFT TERMINAL (WEB LCT) PAGE..................................................................... 14

OPEN/CLOSE THE WEB LCT PAGE ......................................................................................... 15

Open the WEB LCT page from Browser (Ethernet connection) ............................................. 15

Open the WEB LCT page from SCT/LMT ........................................................................... 15

Open more WEB LCT pages............................................................................................ 16

Close the WEB LCT page................................................................................................ 16

ELEMENTS OF WEB LCT PAGE .............................................................................................. 17

Equipment Menu area ................................................................................................... 18

Equipment info area...................................................................................................... 19

Users area................................................................................................................... 20User Profile parameter............................................................................................. 20[Logout] parameter ................................................................................................ 20[Logged Users] parameter ....................................................................................... 20

Verify the users connected to the equipment ........................................................ 21Force the logout of a user .................................................................................. 21

[Open Far End] parameter ....................................................................................... 21Open the WEB LCT page of an equipment (Remote Link) ........................................ 22

[Help] parameter.................................................................................................... 22

Remote elements list area ............................................................................................. 23Verify the remote equipment list ............................................................................... 23Add a station to the list ........................................................................................... 24Rename a station of the list ..................................................................................... 24Remove a station of the list...................................................................................... 24Add an equipment to the list .................................................................................... 25Remove an equipment from the list........................................................................... 25Reset the remote equipment list ............................................................................... 25

Page 4: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

2 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Open the WEB LCT page of an equipment of the list (Remote Link)................................ 26Remote equipment list (info) .................................................................................... 26

Contextual area............................................................................................................ 27

Equipment status area .................................................................................................. 28Verify the active manual operations .......................................................................... 29Verify/modify the manual operation timeout............................................................... 29

MESSAGES DISPLAYED IN WEB LCT PAGE ............................................................................. 30

MENU AND COMMANDS (EQUIPMENT MENU) ......................................................................... 31

MAIN ................................................................................................................................ 32

Equipment Properties .................................................................................................... 33Verify the equipment properties (type, ID, SNMP IP address, etc.) ................................ 33Modify the equipment identifier ................................................................................ 33Modify the IP address of the SNMP agent of the equipment .......................................... 33Align the reference date/time of the equipment to the current date/time of the PC .......... 34Verify the equipment addresses................................................................................ 34Verify the functionalities enabled for the equipment .................................................... 34Enable the new functionalities .................................................................................. 34Verify the equipment units ....................................................................................... 35Execute the equipment software reset ....................................................................... 35Equipment Properties contextual area........................................................................ 36

General Info tab ............................................................................................... 36Network tab ..................................................................................................... 36Equipment Features tab..................................................................................... 37Equipment Units tab.......................................................................................... 37

Port Configuration ........................................................................................................ 39Verify/modify the network address and the supervision parameters of the equipment ...... 39Restore the access to equipment CPU........................................................................ 40Execute the equipment software reset ....................................................................... 40Port Configuration contextual area ............................................................................ 41

Ethernet tab..................................................................................................... 41Management configurations (info) ............................................................................. 42

Routing Table............................................................................................................... 43Verify the Routing Table and the Default Gateway used by the equipment ...................... 43Add an element to the Routing Table......................................................................... 43Remove one or more elements from the Routing Table ................................................ 44Set/modify the IP Address used as Default Gateway .................................................... 44Delete the IP Address used as Default Gateway .......................................................... 44Routing Table contextual area .................................................................................. 45Routing Table and Default Gateway (info) .................................................................. 46

Routing Table ................................................................................................... 46Running Routing Table....................................................................................... 46Stored Routing Table......................................................................................... 46Default Gateway ............................................................................................... 46

Stored Routing Table .................................................................................................... 47Verify the Routing Table and the Default Gateway present into the backup memory of the con-troller.................................................................................................................... 47Add an element into the Stored Routing Table ............................................................ 47Remove one or more elements from the Stored Routing Table ...................................... 48

Page 5: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 3

Set/modify the IP Address used as Default Gateway into the Stored Routing Table .......... 48Delete the IP address used as Default Gateway into the Stored Routing Table................. 48Stored Routing Table contextual area ........................................................................ 49

Performance Monitoring................................................................................................. 50Verify the status, the results and the threshold exceeding alarms of a PM measure.......... 50Activate one or more PM measures ........................................................................... 51Deactivate one or more PM measures ........................................................................ 51Reset the threshold exceeding alarms of one or more PM measures............................... 51Reset the values of the records daily and primary of one or more PM measures............... 51Set the thresholds of the control parameters and alarms of a PM measure...................... 52Performance Monitoring contextual area .................................................................... 54Measures available for ALFOplus80 equipment ............................................................ 58

G828 > Radio 1A .............................................................................................. 58RxPwr > Radio 1A............................................................................................. 58TxPwr > Radio 1A ............................................................................................. 58

PM measures (info) ................................................................................................. 60

Report & Loggers Maint. ................................................................................................ 61Save the configuration, the alarms and the operations executed by the users to file ........ 61Delete the alarms stored into the equipment controller ................................................ 61Delete the operations list stored into the equipment controller ...................................... 62Report & Loggers Maint contextual area..................................................................... 63Report WEB page.................................................................................................... 64

SNTP & Wake Up Config. ............................................................................................... 65Verify the status of SNTP functionality ....................................................................... 65Set the execution parameters and activate the SNTP functionality ................................. 65Disable the SNTP functionality .................................................................................. 66Verify the Wake Up functionality status...................................................................... 66Set the execution parameters and activate the Wake Up functionality ............................ 66Disable the Wake Up functionality ............................................................................. 66SNTP & Wake Up Config. contextual area ................................................................... 67

SNTP tab ......................................................................................................... 67Wake Up tab .................................................................................................... 67

SNTP functionality (info) .......................................................................................... 69Wake Up functionality (info) ..................................................................................... 69

Software Info & Maint. .................................................................................................. 70Verify the firmware version of the equipment ............................................................. 70Update the firmware of the equipment....................................................................... 70Switch the operation of the memory benches relevant to the main controller .................. 71Verify the WEB LCT version present into the equipment ............................................... 71Update the WEB LCT application ............................................................................... 72Verify the communication stack in use ....................................................................... 72Restore Factory Default of the equipment .................................................................. 72Execute the equipment software reset ....................................................................... 73Software Info & Maint contextual area ....................................................................... 74

Equipment Firmware tab.................................................................................... 74WEB LCT tab .................................................................................................... 75IP/OSI stack switch tab ..................................................................................... 75

Equipment firmware (info) ....................................................................................... 76Factory Default of the equipment (info) ..................................................................... 76Rescue connection (info).......................................................................................... 76

Backup/Restore Config. ................................................................................................. 77

Page 6: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

4 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Save the whole equipment configuration (backup configuration) ................................... 77Transfer the equipment configuration previously saved (restore configuration)................ 77Retrieve the equipment configuration automatically saved by the program before the last op-eration of configuration restore (revert configuration).................................................. 78Backup/Restore Config. contextual area..................................................................... 79Backup/restore of the equipment configuration (info) .................................................. 80

Alarm Severity Config. .................................................................................................. 81Verify the severity level and the enabling/forwarding status of the alarms ...................... 81Enable/disable an alarm .......................................................................................... 81Enable/disable the forwarding of the trap of an alarm .................................................. 81Change the severity level of an alarm........................................................................ 82Alarm Severity Config. contextual area ...................................................................... 83Alarms (info).......................................................................................................... 84

Alarm and status signals .................................................................................... 84Enabling/disabling the alarms ............................................................................. 84Enabling/disabling the forwarding of the alarm traps.............................................. 84Alarm severity .................................................................................................. 84

User Manager .............................................................................................................. 85Verify the user list .................................................................................................. 85Add a user to the list............................................................................................... 85Modify a user into the list......................................................................................... 86Delete a user from the list ....................................................................................... 86Change the password and the timeout of the System user............................................ 86Change the network password and timeout ................................................................ 87Change the password and the timeout of NMS5UX user ............................................... 87Verify/modify the IP address of Permanent Login ........................................................ 88User Manager contextual area .................................................................................. 89User list (info) ........................................................................................................ 90

EQUIPMENT ....................................................................................................................... 91

BW & Mod./Link ID ....................................................................................................... 92Verify/modify the reference band/modulation ............................................................. 92Verify/modify the link identification number ............................................................... 92BW & Mod./Link ID contextual area ........................................................................... 93

General Preset ............................................................................................................. 94Verify/modify the threshold level of the signal at reception........................................... 94Verify/modify the radio branch label .......................................................................... 94Verify/modify the generation of the antenna aiming signal ........................................... 94General Preset contextual area ................................................................................. 95

SYNCHRONISATION............................................................................................................ 96

Verify/modify the management of synchronisation ............................................................ 96

Verify the status and configuration of the T0 synchronism.................................................. 96

Force the status of T0 synchronisation............................................................................. 97

Set the Hold Off Time parameter .................................................................................... 97

Set the WTR Time parameter ......................................................................................... 97

Set the threshold levels of LTI alarm ............................................................................... 97

Enable/disable the use of a synchronism source................................................................ 98

Modify the use priority of a synchronism source................................................................ 98

Force the use of a synchronism source ............................................................................ 98

Set a synchronism source as preferential ......................................................................... 99

Page 7: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 5

Restore the availability of a source for the selection of the T0 synchronism without waiting for the expiry of Wait Time....................................................................................................... 99

Synchronisation contextual area ....................................................................................100General tab...........................................................................................................100T0 tab ..................................................................................................................101

Synchronisation (info) ..................................................................................................102Management of synchronisation...............................................................................102Synchronism sources .............................................................................................102

Enabling of the synchronism sources ..................................................................102Priority of the synchronism source......................................................................102Forcing of a synchronism source ........................................................................103Function of preferential synchronism source ........................................................103

Internal synchronism T0 .........................................................................................103

BASE BAND ......................................................................................................................104

Ethernet Switch...........................................................................................................105Verify/modify the Eth Type value in the S_Tag QinQ field ............................................105Verify/modify the maximum size of the accepted packet .............................................105Verify/modify the address learning modality in MAC Table ...........................................106Verify/modify the aging time of the addresses stored in the MAC Table .........................106Reset the MAC Table ..............................................................................................106Verify/modify the emptying algorithm of the packets present in the output queue ..........107Verify/assign the output queue to a packet according to its Tag 802.1p (level 2) ............107Verify/assign the output queue to a packet according to its PTOS/DSCP field (level 3).....107Verify/modify the hysteresis of the Link Loss Forwarding modality................................108Verify the existing virtual LANs ................................................................................108Create a virtual Lan ...............................................................................................109Modify the configuration of a virtual Lan ...................................................................110Delete a virtual Lan................................................................................................110Ethernet Switch contextual area ..............................................................................111

General tab.....................................................................................................111LLF tab...........................................................................................................112PTOS/DSCP Config. tab.....................................................................................112Virtual Lan Config. tab......................................................................................113

Ethernet Switch (info) ............................................................................................114Limitations in the configuration of the Ethernet Switch ..........................................114Addition of S-TAG (QinQ – Double Tag) in a packet with C-TAG..............................117Analysing the priority .......................................................................................117MAC Table ......................................................................................................118

LAN 1, LAN 2 ..............................................................................................................119Verify/modify the enabling status of the LAN .............................................................120Verify/modify the inversion status of the Tx and Rx lines of the LAN .............................120Verify/modify the enabling status of the auto negotiation and, if the auto negotiation is inac-tive, the operation modality and the transmission speed used by the LAN......................120Verify/modify the enabling status of the flow control of the LAN ...................................121Verify/modify the automatic learning of the addresses in MAC Table for the LAN ............121Restart the auto negotiation procedure for the LAN ....................................................121Verify/modify the operating modality of the line synchronism (role) for the LAN .............122Verify/modify the activation status of the autonegotiation between the roles of the line syn-chronism for the LAN..............................................................................................122Verify/modify the default VID value of the LAN ..........................................................122Verify/modify the management of 802.1Q field on the messages in input from the LAN...123Verify/modify the traffic transport modality (point-point or Bridge)...............................123

Page 8: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

6 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the management of Provider Tag in the packets in input from the LAN ......124Verify/overwrite the C-VID value of the packets in input from the LAN and forwarded to the Radio with a different VID.......................................................................................124Verify the list of VIDs registered in VLAN Table Unit and associated to the LAN ..............125Verify/modify the management of the LAN in Provider mode........................................125Verify/modify the ports through which the messages in input from the LAN can transit ...125Verify/modify the priority criterion used to associate the packets in input from the LAN to the output queue ........................................................................................................126Verify/modify the value of default priority 802.1p.......................................................126Verify/remap the priority (802.1p) inside the Tag VLan of the LAN ...............................126Verify/modify the enabling status of Link Loss Forwarding modality of the LAN...............127Activate/deactivate the loop on line side of the LAN....................................................127Verify the status and the configuration of the laser (LAN)............................................128Modify the enabling status of the laser (LAN).............................................................128Modify the transmission mode of the laser (LAN)........................................................128Enable manually the laser transmission (LAN)............................................................129Execute the test laser operating status (LAN) ............................................................129LAN 1, LAN 2 contextual area ..................................................................................130

Interface tab ...................................................................................................130802.1Q Management tab...................................................................................132Port Based VLAN tab ........................................................................................133Priority Management tab...................................................................................134LLF tab...........................................................................................................134Line Loop tab ..................................................................................................135Laser Control tab .............................................................................................135

Port A ........................................................................................................................137Verify/modify the enabling status of the internal port .................................................137Verify/modify the enabling status of the flow control of the internal port .......................137Verify/modify the automatic learning of the addresses in the MAC Table for the internal port .....................................................................................................................138Verify/modify the control of Tag Vlan Id on the messages in input from the internal port .138Verify/modify the default VID value of the internal port...............................................139Verify/overwrite the C-VID value of the packets in input from the internal port and forwarded to a LAN, with a different C-VID...............................................................................139Verify/modify the ports through which the messages in input from the internal port .......139Verify/modify the priority criterion used to associate the packets in input from the internal port to the output queue of the LAN................................................................................140Verify/modify the default value of priority .................................................................140Verify/modify the mapping of the priority (802.1p) inside the Tag VLan of the internal port .....................................................................................................................140Port A contextual area............................................................................................141

Interface tab ...................................................................................................141802.1q Management tab ...................................................................................141Port Based VLan tab.........................................................................................142Priority Management tab...................................................................................142

RADIO BRANCH.................................................................................................................144

Verify/modify the duplex frequency................................................................................144

Verify/modify the frequency which the equipment transmitter is tuned on ...........................144

Verify/modify the modulation status of the RF carrier .......................................................145

Verify/modify the operation of the transmitter .................................................................145

Verify/modify the resolution of the received power (Prx) ...................................................145

Verify/modify the resolution of the transmitted power (Ptx)...............................................146

Page 9: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 7

Verify/modify ATPC operating status ..............................................................................146

Verify/modify the maximum output power value at the transmitter ....................................146

Verify/modify the ATPC regulation range.........................................................................146

Verify/modify the thresholds of ATPC device....................................................................147

Radio Branch contextual area........................................................................................148Settings tab ..........................................................................................................148Powers tab............................................................................................................149

MAINTENANCE ..................................................................................................................150

Lan Statistics ..............................................................................................................151Verify the counters of the packets/bytes in input/output from the Ethernet ports subdivided by each port .........................................................................................................151Reset the counters’ results......................................................................................151Lan Statistics contextual area..................................................................................152

Lan Stat. Summary......................................................................................................154Verify the summary of the main counters of the Ethernet ports....................................154Reset the counters’ results......................................................................................154Lan Stat. Summary contextual area .........................................................................155

Advanced Stat. Mon.....................................................................................................156Verify/manage the main counters of the Radio port whose traffic is filtered according to Inter-nal Priority value ...................................................................................................156Verify/manage the main counters of the Radio port whose traffic is filtered according to C-VID identifier...............................................................................................................157Verify/manage the main counters of the Radio port whose traffic is filtered according to the S-VID and C-VID identifiers.....................................................................................159Advanced Stat. Mon. contextual area........................................................................161

RMon .........................................................................................................................162Verify the collection status of the statistic counters of the equipment Ethernet ports .......162Activate the collection of the statistic counters for an Ethernet port ..............................162Deactivate the collection of the statistic counters for an Ethernet port...........................162Display the values of statistical counters of an Ethernet port........................................163RMon contextual area.............................................................................................164

Remote Monitoring window ...............................................................................164Implementation of the RMon standard in the equipment managed by WEB LCT ..............166

RMon Standard................................................................................................166Outline on the operation of RMon standard..........................................................166Management from Web LCT of the statistics counters foreseen by RMON standard....166Ethernet counters (RMon) .................................................................................167

S/N Meas ...................................................................................................................168Verify the value of the S/N measure.........................................................................168Update the value of the S/N measure .......................................................................168S/N Meas. contextual area ......................................................................................169

Radio BER ..................................................................................................................170Verify the status and the configuration parameters of Radio BER measure .....................170Activate the measure (BER and error count)..............................................................170Deactivate the measure (BER and error count) ..........................................................170Radio BER contextual area ......................................................................................171

Radio Loop .................................................................................................................172Verify the radio loops status....................................................................................172Activate a radio loop ..............................................................................................172Deactivate a radio loop...........................................................................................172Radio Loop contextual area .....................................................................................173

Page 10: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

8 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Loop (info)............................................................................................................174

ALARMS LIST ....................................................................................................................... 175

OPERATIONS LIST ............................................................................................................... 179

PARAMETERS LIST ............................................................................................................... 185

ASSISTANCE SERVICE.......................................................................................................... 189

Page 11: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 9

MANUAL CONTENT

This manual describes the commands and functionalities of WEB Local Craft Terminal application (re-lease 1.2) present in ALFOplus80 equipment (Full Outdoor version).

The WEB LCT release present in the equipment can be verified opening the relevant WEB Local Craft Ter-minal page and selecting, in Equipment Menu area, one of the following commands:

• Main > Equipment Properties - General Info tab - WEB LCT Version parameter.• Main > Software Info & Maint. - Web LCT tab - Current Version parameter.

In this manual, to make the writing easier, the wording:• WEB LCT identifies the WEB Local Craft Terminal application for ALFOplus80.• WEB LCT page identifies the WEB Local Craft Terminal page for ALFOplus80.

Page 12: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

10 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

WEB LCT APPLICATION

WEB LCT application allows an user connecting to an equipment via his own machine (PC, Workstation,etc.) using the operating system and the Web browser at his disposal.

WEB LCT is an application resident in the equipment controller. It does not require any additional moduleinstalled on the user PC (see Installation).

At start-up of WEB LCT application, the browser displays the WEB Local Craft Terminal (WEB LCT) page.

The WEB LCT page can be opened directly from browser or from SCT/LMT program (see Open/close theWEB LCT page).In the first case, the WEB LCT interface of the equipment, whose IP is entered in the address bar of thebrowser, is opened (see Fig.1).In the second case, the WEB LCT interface of the equipment selected in SCT/LMT application is opened(see Fig.2).

Through WEB LCT application, the user can check the equipment operating status and directly interveneto manage it, verifying/modifying the configuration parameters (see Functionalities and Menu and com-mands (Equipment Menu).

Fig.1 WEB LCT application (start-up of WEB LCT page from browser)

Fig.2 WEB LCT application (start-up of WEB LCT page from SCT/LMT)

Controller

Equipment(e.g. 172.18.60.33)

Supervisionport

NEmanagement

WEB LCTapplication

WEB LCT pageequipment

(172.18.60.33)

SCT/LMTor

Web Lct Console

User PCBrowser

FTPHelp Web Server

Internet(HTTP)

Controller

Equipment(e.g. 172.18.60.33)

Supervisionport

NE management

WEB LCTapplication

User PC

Internet(HTTP)

FTPHelp Web Server

WEB LCTpage

equipment(172.18.60.33)

Equipment(172.18.60.33)

SCT/LMT

Page 13: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 11

FUNCTIONALITIES

Through the WEB LCT application, it is possible to manage:• The properties (identifier, addresses, reference date/time, hardware, features key, etc.) and to

execute the reset of the equipment software (Equipment Properties).• The network address and the supervision parameters of the equipment (Port Configuration).• The stating Routing Table and the Default Gateway address currently used by the equipment

(Running Routing Table and Running Default Gateway) (Routing Table).• The static Routing Table and the Default Gateway address stored in the equipment (Stored Rout-

ing Table and Stored Default Gateway) (Stored Routing Table).• The measures of Performance Monitoring (Performance Monitoring).• The saving to file of the equipment configuration, of the status/alarm signals and of the opera-

tions executed by the users (Report & Loggers Maint.).• The automatic acquisition of the reference date/time of the equipment from a network element

and the Wake Up trap (SNTP & Wake Up Config.).• The equipment firmware, the WEB LCT software present in the equipment, the communication

stack used by the equipment and the restore of the default equipment settings (Software Info& Maint.).

• The backup/restore of the whole equipment configuration (Backup/Restore Config.).• The forward status of the alarms and their severity level (Alarm Severity Config.).• The equipment users list (User Manager).• The equipment general configuration (Equipment).• The sources and the synchronism parameters (Synchronisation).• The Ethernet Switch (Base Band).• The radio parameters (Radio Branch).• The LAN statistics, RMon, S/N, Radio BER and radio loops (Maintenance).• The Remote elements list area• The manual operations and the relevant timeout (Equipment status area).• The users connected to the equipment ([Logged Users] parameter).

Page 14: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

12 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

LIMITS

Maximum number of... Limit

Equipment in remote equipment list 100

Stations in remote equipment list 30

Equipment which can be connected contemporarily via a single WEB LCT page

1

Users (WEB LCT, SCT/LMT and NMS5UX) contemporarily connected to an equipment via the WEB LCT page

2

Signals in the Events area 400

Page 15: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 13

INSTALLATION

WEB LCT is an application resident in the equipment controller. It does not require any installation on theuser PC.To install or update the WEB LCT application present in an equipment, see Update the WEB LCT application.

The program SCT/LMT or WEB Lct Console (1) must be used as help for the WEB LCT application, in orderto manage the transfer of files between PC and equipment (FTP) and of the help-on-line of WEB LCT (HelpWeb Server).The instructions for the installation of the SCT/LMT and Web Lct Console programs are reported in the rel-evant manuals.

(1) The programs SCT/LMT and WEB LCT Console work in MS Windows® environment. For operating sys-tems different from MS Windows®, the user must install a FTP server and a Help WEB server on one’s PC.

Page 16: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

14 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

WEB LOCAL CRAFT TERMINAL (WEB LCT) PAGE

Open/close the WEB LCT pageElements of WEB LCT pageMessages displayed in WEB LCT page

Page 17: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 15

OPEN/CLOSE THE WEB LCT PAGE

Open the WEB LCT page from Browser (Ethernet connection)Open the WEB LCT page from SCT/LMTOpen more WEB LCT pagesClose the WEB LCT page

Open the WEB LCT page from Browser (Ethernet connection)

WARNING If Ethernet connection is used, checks or settings are not generally necessary. Only if more net-work cards are equipped, it will be necessary to select the card you wish to use (Host Adapter) (see WebLct Console user manual).When the equipment is connected to the PC via LAN network, the relevant WEB LCT page can be openedalso selecting the equipment from the address book of Web Lct Console (see relevant documentation).The following procedure requires that:

• The relevant WEB LCT application is present on the equipment which you are connecting to. • The user, you wish to use to open the WEB LCT page, is valid. With valid user (username and

password) we mean an user present in the users list stored in the controller (see User list (info).

1. Run WEB Lct Console program (see relevant documentation).The WLC program must be used as help for the WEB LCT application, in order to manage the FTP, PPPand Help Web Server

2. Run a browser.

3. Type in the address box: http://<IP address of the equipment>

With IP address we mean the address of the equipment supervision port from which you wish to reachthe equipment itself.The WEB LCT login page opens.

4. Type the name of the SCT/LMT user, in the Username box.

5. Type the access, in the Password box,

6. Check the Remember Me box if you wish that, on the next opening of the application, the current username and password are automatically displayed; otherwise uncheck the considered box.

7. Press Login. If the typed values are correct, the system displays the WEB LCT page of the equipment (see Fig.3).As regards the messages that can be displayed during the start procedure of WEB LCT see Messagesdisplayed in WEB LCT page.

Open the WEB LCT page from SCT/LMT

WARNING The following procedure requires that:• The relevant WEB LCT application is present on the equipment you are connecting to. • The user, you wish to use to open the WEB LCT page, is valid. With valid user (username and

password) we mean an user present in the users list stored in the controller (see User list (info).• The SCT/LMT is installed on the PC. More information about the SCT/LMT program is reported

in the relevant documentation.

Page 18: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

16 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

1. Run SCT/LMT program (see relevant documentation).

2. Activate the connection with the wished equipment (see relevant documentation).

3. Execute one of the following operations:• Double click on the record representing the equipment in the SCT/LMT window.• Select the record of the equipment and then the Equipment > LCT Interface command.

The system displays the WEB LCT page of the equipment (see Fig.3).As regards the messages that can be displayed during the start procedure of WEB LCT see Messagesdisplayed in WEB LCT page.At the opening of the WEB LCT page, the user will be connected to the equipment with the user/profileof the equipment in the SCT/LMT window.In any moment, it is possible to execute the logout and re-execute the login using the same or a dif-ferent user with respect to that used for the login.

In this case, there is no need to differentiate the opening of the WEB LCT page according to the connectiontype, as the connection management is executed by the SCT/LMT program itself. For more information,refer to the relevant documentation.

Open more WEB LCT pages

It is possible to open:• More WEB LCT pages on more machines or on the same machine, using the same user or dif-

ferent users.• Only one WEB LCT page relevant to the same equipment.• More WEB LCT pages relevant to different equipment.

For more information about the limits of the application, refer to the Limits paragraph.

Close the WEB LCT page

Select the [Logout] parameter.

Page 19: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 17

ELEMENTS OF WEB LCT PAGE

1 - Equipment Menu area2 - Equipment info area3 - Users area4 - Remote elements list area5 - Contextual area6 - Equipment status area

Fig.3 shows an example of WEB LCT page of ALFOplus80 equipment.

Fig.3 Elements of the WEB LCT page (ALFOplus80)

1 23

45

6

Page 20: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

18 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Equipment Menu area

The Equipment Menu area contains the commands to manage the equipment configuration (see Fig.3).

The commands are subdivided in groups:Main. Commands to manage the general equipment parameters: supervision ports, Routing Table,Performance Monitoring measures, etc.Equipment, Synchronisation, etc. Commands to manage the configuration parameters typical ofthe equipment type which the WEB LCT page refers to.

The description of every group/command is reported in paragraph Menu and commands (EquipmentMenu).

The selection of a group expands or compresses the list of the underlaying commands.At each selection, the list takes the status complementary to the previous one (if compressed it becomesexpanded, or vice versa).The symbol:

• identifies an expanded group.• identifies a compressed group.

It is possible:• Expand all the groups at the same time, pressing • Compress all the groups at the same time, pressing .

The symbol identifies a command which, once selected, displays the parameters associated to it in thecontext area (see Contextual area).

When the WEB page is opened, the Equipment Menu area is displayed.

In any moment, it can be hidden pressing present in the area itself (see Fig.3).

To display the area again, press the relevant button .

Page 21: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 19

Equipment info area

The Equipment info area indicates the equipment general properties:

Equipment Type. Equipment type.

Equipment ID. Equipment identifier.

Agent IP Address. IP Address assigned to the SNMP agent of the equipment.

The left table (see Fig.3) shows the status and radio parameters of the transmitter and receiver.Every row of the table corresponds to a radio branch for which is displayed:

Branch which the data, present in the relevant row, refer to:• Tx1A. Operating status and radio parameters of the branch relevant to transmission.• Rx1A. Operating status and radio parameters of the branch relevant to reception.

RF frequency. The wording ODU Hardware Failure indicates a hardware problem.

Power in input to the receiver (line Rx1A) and in output to the transmitter (line Tx1A). Both thepowers are measured at the antenna flange.The wording Tx Off (line Tx1A) indicates that the transmitter is off because of an action of the user(see Verify/modify the operation of the transmitter - selection of Off or Permanent Off option) orbecause of the activation of one or more alarms which cause the switch-off of the transmitter (forexample, RADIO Vco Fail Alarm).

The right table (see Fig.3) shows the channel/modulation and the Ethernet radio traffic (Tx/Rx):

Bandwidth & Modulation. Current channel and modulation.

ETH Capacity. Radio capacity reserved to Ethernet tributaries.

The information in the Equipment Info area can be updated pressing .

When the WEB page is opened, the Equipment Info area is displayed.

In any moment, it can be hidden pressing present in the area itself (see Fig.3).

To display the area again, press the relevant push-button .

Page 22: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

20 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Users area

In the Users area is present:User Profile parameter[Logout] parameter[Logged Users] parameter[Open Far End] parameter[Help] parameter

User Profile parameter

The User Profile parameter shows the login and profile of the user who has opened the WEB LCT page:

System. The equipment is in connected/login status and the user has System profile. The System user can both verify the parameters and send commands or change the equipment con-figuration with no exception.

Station Op. The equipment is in connected/login status and the user has Station Operator profile. The Station Operator user can as check the parameters as send commands or execute changes tothe equipment configuration except for the following operations: modifying the user list, aligningthe date/time of the equipment, force the logout of an user and all those operations available onlyto the System user (or NMS5UX).

Read & Write. The equipment is in connected/login status and the user has Read & Write profile. The Read & Write user can check the parameters and execute only maintenance operations (MANOP).

Monitor. The equipment is in connected/monitor status or in connected/login status and the userhas Read Only profile.The Read Only user can check the parameters but it can not forward commands or execute changingto the equipment configuration.

At the opening of the WEB LCT page, the user will be connected to the equipment with the user/profileentered during the login request.In any moment it is possible to execute the logout and re-execute the login using the same or a differentuser with respect to that used for the login.

If the equipment is managed also by the NMS5UX/NMS5UX-B/NMS5LX supervisory system, the supervi-sory system considers the connection of a SCT/LMT user with Read Only profile a WEB LCT connection inMonitoring mode.While the supervisory system considers the connection to the equipment of a SCT/LMT user with Read &Write, Station Operator or System profile a WEB LCT connection in Configuration mode.

[Logout] parameter

The [Logout] parameter executes the logout of the current user. When selected, the WEB LCT page to login to the equipment is displayed.To reconnect equipment, set Username and Password and press Login.

[Logged Users] parameter

The [Logged Users] parameter manages the users connected to the equipment.

Page 23: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 21

In detail, the parameter allows:Verify the users connected to the equipmentForce the logout of a user

Verify the users connected to the equipment

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select the [Logged Users] parameter.The Current Logged User window displays the list of the users connected to the equipment when thecommand is selected.For each users, is pointed out in the column:

• User. User name.The wording NMS5UX shows the user of the NMS5UX/NMS5UX-B/NMS5LX supervisory systemor a remote user (different from WEB LCT, SCT/LMT or NMS5UX user) who has the possibility tobe connected to the equipment (Permanent Login).The other wordings identify the WEB LCT or SCT/LMT users connected to the equipment.

• Profile. User profile.• Timeout. Timeout of the WEB LCT session:

• No Timeout. Session timeout disabled. WEB LCT session opened by the user (even if dis-connected) will be kept for an indefinite period of time.

• <number> Seconds. Session timeout enabled. WEB LCT session opened by the user, ifdisconnected, will be automatically ended once reached the set time limit.

With disconnected session we mean a WEB LCT session whose relevant WEB LCT has beenclosed but for which the disconnection from the equipment has not been executed (user logout).

• User IP Address. Machine IP address.With the wording machine, it is intended the PC (for the WEB LCT and SCT/LMT users) or theserver/ workstation (for the NMS5UX users and remote users) on which the application used bythe user is actually running.

Press Refresh to update the data present in the window.

Force the logout of a user

User Profile | System

WARNING Logging out oneself is not possible.If the logout of a NMS5UX user is forced, the NMS5UX/NMS5UX-B/NMS5LX supervisory system automati-cally executes the restore of the user login.

1. Select the [Logged Users] parameter.

2. Select the wished user.

3. Press Force Logout and confirm.The system removes the line relevant to the selected user.If the push-button is not available, this means that the record relevant to one’s user has been selected.

[Open Far End] parameter

The [Open Far End] parameter allows to Open the WEB LCT page of an equipment (Remote Link) containedin the Remote Element Table.

Page 24: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

22 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Open the WEB LCT page of an equipment (Remote Link)

User Profile | System

1. Select the [Open Far End] parameter.If the remote equipment list contains:

• Only one equipment of type Remote Link, the WEB LCT login page of the remote equipment isdisplayed.Type the name (Username box) and the access code (Password box) of the SCT/LMT user to useto activate the connection and press Login. In a new page the WEB LCT of the remote equip-ment is displayed.If the WEB LCT login page is not displayed when the login is required, this means that the remoteequipment is unreachable.

• No equipment of type Remote Link, a message is displayed pointing out the absence of the re-mote equipment.

• More equipment of type Remote Link, the Available Remote Elements window is displayed, con-taining the list of equipment configured as Remote Link present in the remote equipment list.For each equipment, the following characteristics are reported:

• Station. Station name.• Equipment ID. Equipment identifier.• IP Address. IP address.

Select the remote equipment and press Open or double click on the equipment.The WEB LCT page to login to the remote equipment opens.Type the name (Username box) and the access code (Password box) of the SCT/LMT user to useto activate the connection and press Login. In a new page the WEB LCT of the remote equip-ment is displayed.

[Help] parameter

The [Help] parameter opens the help online of application.

Page 25: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 23

Remote elements list area

In the Remote elements list area, you can manage the remote equipment list stored in the equipment con-troller.In detail, it possible:

Verify the remote equipment listAdd a station to the listRename a station of the listRemove a station of the listAdd an equipment to the listRemove an equipment from the listReset the remote equipment listOpen the WEB LCT page of an equipment of the list (Remote Link)

The area Remote elements list can be hidden pressing the button present in the area itself (see Fig.3).

To display the area again, press the relevant push-button .

When the WEB page is opened, the Remote elements list area is hidden.

In order to deepen this topic, see Remote equipment list (info)

Verify the remote equipment list

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. In WEB LCT page, expand the area Remote elements list selecting the push-button present in thearea itself (see Fig.3).The area indicates the remote equipment list stored in the equipment controller.Equipment is subdivided into stations.The symbol identifies the station.Selecting the symbol of a station expands or compress the list of underlaying equipment. At each se-lection, the list takes the status complementary to the previous one (if compressed it becomes expand-ed and vice versa).For each station, the name of the station is displayed in the Station/Equip. column.The name of the station is assigned by the user during the creation of the station itself.The stations are displayed in the same order as they are inserted in the listAn empty station, that is a station without associated equipment, cannot be stored in the list.The symbol or identifies the equipment. The first symbol represents the equipment of type Managed by SCT, Elem. Manager, Not Managed; thesecond symbol represents the equipment of type Remote Link (see column Type). In the Station/Equip. column, the equipment name is displayed. The name of the equipment is auto-matically assigned by the application during the creation of the equipment itself: Equipment <progres-sive number>.Within the station, the equipment are listed in increasing order with respect to the IP address.For each equipment is pointed out in the column:

• IP Addr. IP address (Agent SNMP).• Type. Type of equipment:

• Managed by SCT. Equipment managed by WEB LCT and/or SCT/LMT application.• Remote Link. Equipment, managed by WEB LCT and/or SCT/LMT application, constituting

the equipment placed on the other end of the radio connection with respect to the localequipment (equipment which the user is connected to by WEB LCT).

• Elem. Manager. Element Manager of the equipment (IP address of the machine wherethe NMS5UX/NMS5UX-B/NMS5LX system resides).

Page 26: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

24 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Not Managed. Element not managed by the WEB LCT and/or SCT/LMT application. This option can be used to insert into the remote equipment list for instance the couplingbetween the IP address and the NSAP (Gosip) one of an equipment inserted into an OSInetwork.

• OSI. Equipment NSAP (GOSIP) Address.Parameter available only for the equipment managed with the OSI protocol.

Press Refresh to refresh the list.

Add a station to the list

User Profile | Station Operator, System

WARNING A maximum of 30 stations can be inserted in a list.

1. In the Remote elements list area, press Add (Station group).

2. Type, in the text box, the name to be assigned to the station (alphanumeric string with minimum 1 andmaximum 11 characters).The program does not create two stations with the same name in the same list. Moreover, a digit cannotbe used as first character and the space character cannot be used at the beginning or within the namestring.

3. Press OK.The application displays the new station into the Remote elements list area, at the end of the list rele-vant to the already existing stations.

4. Press Apply and confirm.An empty station, that is a station without associated equipment, is not saved in the list.

Rename a station of the list

User Profile | Station Operator, System

1. In the Remote elements list area, select the station to be renamed.

2. Press Rename.

3. Type, into the text box, the new name (alphanumeric string with minimum 1 and maximum 11 char-acters).The program does not create two stations with the same name in the same list. Moreover, a digit cannotbe used as first character and the space character cannot be used at the beginning or within the namestring.

4. Press OK.The application displays the new name of the station into the Remote elements list area.

5. Press Apply and confirm.

Remove a station of the list

User Profile | Station Operator, System

WARNING Deleting the station causes even the removal of all the equipment associated to this station.

1. In the Remote elements list area, select the station to be removed.

2. Press Remove (Station group).The application removes the station from the Remote elements list area.

3. Press Apply and confirm.

Page 27: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 25

Add an equipment to the list

User Profile | Station Operator, System

WARNING A maximum of 100 equipment can be added to the list.An equipment cannot be created if at least one station has not been created before.

1. In the Remote elements list area, select the station to which the equipment has to be coupled.If the user does not select any station, the application will automatically associated the equipment tothe last selected station.

2. Press Add (Element group).

3. Type the IP address of the equipment in IP Address box.The program does not create two equipment with the same IP Address in the same list (even if in dif-ferent stations).

4. Only if the equipment is inserted into an OSI network, set the NSAP address (Gosip Address box) open-ing the popup menu and setting in the box:

• AFI, IDI, Ver, Auth, Reserv. e Sel, the value of the corresponding byte/s.• Domain, the values of the bytes that represent the Domain.• Area, the values of the bytes that represent the area.• Sys. ID, the value of the wished System ID.

5. Press OK.

6. Set the Type of element box, selecting the option relevant to the element type to be inserted:• Managed by SCT. Equipment managed by the WEB LCT and/or SCT/LMT application.• Remote Link. Equipment managed by the WEB LCT and/or SCT/LMT application that constitutes

the equipment placed on the other end of the radio connection with respect to the local equip-ment (equipment which the user is connected to by WEB LCT).

• Element Manager. Element Manager of the equipment (IP address of the machine where theNMS5UX/NMS5UX-B/NMS5LX system resides).

• Not Managed. Element not managed by the WEB LCT and/or SCT/LMT application.This option can be used to insert in the remote equipment list for instance, the association be-tween the IP address and the NSAP (Gosip) address of an equipment inserted in an OSI network.

7. Press OK.In the Remote elements list area, under the selected station, a record named Equipment <progressivenumber> is displayed with the characteristics of the new equipment.

8. Press Apply and confirm.

Remove an equipment from the list

User Profile | Station Operator, System

1. In the Remote elements list area, select the equipment to be removed.

2. Press Remove (Equipment group).The application removes the station from the Remote elements list area.

3. Press Apply and confirm.

Reset the remote equipment list

User Profile | Station Operator, System

1. In the Remote elements list area, press Clear.The application clears all the records (stations and equipment) present into the Remote elements listarea.

2. Press Apply and confirm.

Page 28: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

26 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Open the WEB LCT page of an equipment of the list (Remote Link)

User Profile | Station Operator, System

1. In the Remote elements list area, select the equipment of Remote Link type to be opened the WEB LCTpage.

2. Press Open.The WEB LCT page to login to the remote equipment opens.

3. Type the name (Username box) and the access code (Password box) of the SCT/LMT user to use toactivate the connection and press Login. In a new page the WEB LCT of the remote equipment is displayed.

Remote equipment list (info)

Every equipment has a remote equipment list stored in its own controller.

With remote equipment list we mean a list containing all the network remote equipment which you wishto connect to.

For a better vision of the equipment during the setting of the list, the equipment can be subdivided intostations in such a way that, when a station is selected, the application will display only the detail of theequipment associated with this specific station. The station does not have any particular meaning: it hasbeen simply introduced to help the user during the localization of the equipment.

In every remote equipment list, a maximum of 100 equipment and 30 stations can be created.

The remote equipment list can be used to connect, at the same time, to more equipment only if the pro-gram SCT/LMT is available.

When the user requests the connection to a generic equipment present into the network (local equipment),at the connection of this equipment, SCT/LMT program reads its remote equipment list and automaticallyforwards the connection command to all the equipment present into the list.

In this way, the application displays, in the Station List area of SCT/LMT graphical interface, all the stationsthat group the equipment and, in the Equipment List area (selecting the relevant station), it displays thefunctional status of the local equipment (that results in connected/login status) and the functional statusof all the remote equipment present in the list. The equipment which have answered to the connectionrequest of the application will result in connected/monitor status.

The application will cyclically forward the connection command, to the equipment which have not answeredto the connection request, until to:

• The connection with the local equipment is deactivated.• The user disables the equipment.• The equipment is deleted from the remote equipment list of the local equipment.

More details about SCT/LMT program are reported into the relevant manuals.

Page 29: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 27

Contextual area

The contextual area is the part of the WEB LCT page where the equipment parameters are displayed.Its content changes accordingly to the selected command in the Equipment Menu area.

In the top part of the contextual area, there are push-buttons used to confirm or update the data presentin the area itself. Usually, there are:

Apply. Selecting it makes the changes, executed on the parameters present in the contextual area,effective.Its selection opens a confirmation window. The confirmation windows are timed. When this periodis elapsed (pointed out by the progress bar), if the user has not confirmed the operation, the windowis closed and the operation cancelled.If the push-button is not available:

• It is not possible to execute changes because the user profile does not allow this or theequipment is in connected/monitor status.

• No parameter present in the window has been modified. In this case, the push-button be-comes available when the value of a parameter is changed.

• Another push-button is present in the contextual area for the confirmation of the operationor the change of the parameters.

Refresh. Force the reading of the data from equipment.If the push-button is not available, the connection with the equipment is not active.

Help. Open the help on-line.

For some commands, other push-buttons are displayed relevant only to the context which contains them.These push-buttons are described in the paragraph relevant to the specific command.

Besides the push-buttons, the top part of the contextual area dynamically displays the group and the com-mand selected in Equipment Menu area and which the displayed parameters refer to.

For some commands, the parameters are subdivided in tabs. The selection of a tab dynamically changesthe content of the contextual area.

The parameters present in the contextual area can be read-only or set or modified.The description of the single commands (see Menu and commands (Equipment Menu) indicates the param-eters which can be modified and modalities to do that.Generally, for the parameter setting, the following rules are valid:

• Entering a value (alphanumeric string) in a text box.If a red line is displayed below the text box, the entered value is not allowed because, for ex-ample, a number of characters greater than the allowed one or an invalid value has been entered(for example, entering of value 172.18.70.334 as IP address).

• Box with possible values displayed in a drop-down menu.When the value is changed, a red triangle is displayed in the top left edge of the box. It signalsthat the value has been changed, but the change has not been communicated yet to the equip-ment (pressure of push-button Apply).

Page 30: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

28 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Equipment status area

The Equipment status area indicates the functional status of the equipment. Area/box:

Events. List of the status/alarm signals of the equipment.Each signal corresponds to a record that is displayed:

• Coloured box. Signal type and alarm gravity:• Green/Status. Status signal.• Light blue/Warning. Alarm detected with Warning severity.• Yellow/Minor. Alarm detected with Minor severity.• Orange/Major. Alarm detected with Major severity.• Red/Critical. Alarm detected with Critical severity.• White/Cleared. Alarm detected/cleared.

• Alphanumeric string which details the nature of the signal.• Logic group which the signal belongs to: COMMON, etc.• Date/time of the signal detection.

If the row refers to a detected/cleared alarm, the date/time of alarm detection will be pointedout under the date/time of alarm clearing.The date/time is set by the network element that has generated the signal. The format of date/time changes depending on the setting made in the operating system.

When the WEB page is opened, the Events area is displayed. Press to hide the area (see Fig.3). Press to display the area again.

Press to dynamically update information and remove the detected and cleared alarms (box White/Cleared).

URGENT <alarms number>. Number of Critical and/or Major alarms. Colour box:• Orange. The most serious alarm present into the equipment has Major severity• Red. The most serious alarm present into the equipment has Critical severity.• Grey. The equipment has no active alarms with Critical or Major severity.

Select the box to display the detail of the active alarm.

NOT URG. <alarms number>. Number of Minor and/or Warning alarms. Colour box:• Light blue. The most serious alarm present into the equipment has Warning severity.• Yellow. The most serious alarm present into the equipment has Minor severity.• Grey. The equipment has no active alarms with Minor or Warning severity.

Select the box to display the detail of the active alarm.

DOWNLOAD. Update of the equipment firmware. Colour box:• Light blue. The firmware update is in progress.• Grey. The firmware update is not in progress.

MAN. OP. Activation of the manual operations. Colour box:• Light blue. A manual forcing is enabled (e.g. a loop).• Grey. No manual forcing is active.

Select the box to:Verify the active manual operationsVerify/modify the manual operation timeout

The information displayed in the Equipment status area are updated at regular intervals depending on thetimeout set by the user.The progress of the bar ( ) indicates the time between two successive updates.Select the bar to display the current timeout.To change the parameter, move the cursor to the new value (number between 5 and 30 seconds).

In order to deepen this topic, see Alarms (info)

Page 31: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 29

Verify the active manual operations

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select the MAN. OP box.A window displays the manual operations actually activated into the equipment.The wording None active manual operation indicates that no manual operation is active.The information are not dynamically updated. Press to update the information.

Verify/modify the manual operation timeout

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The timeout setting is common for all the manual forcing operations of the equipment.

1. Select the MAN. OP box.The Manual Operation Timeout box displays the current timeout of the manual operations.Value 0 indicates that the timeout has not been activated, this means that the activation of a manualoperation remains active until when the user deactivates it. The activation of a manual forcing (for in-stance a loop) affects the traffic.

2. To change the parameter, set a value between 0 and 172800 sec. (48 hours).The setting of the value 0 corresponds to the disabling of the timeout.

3. Press Change and confirm.

Page 32: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

30 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

MESSAGES DISPLAYED IN WEB LCT PAGE

At the opening of WEB LCT page, one of the following messages can be displayed:

Welcome in the WebLct Software upload utility.... The WEB LCT program is not present on the equip-ment you wish to connect to. Update the WEB LCT application.

Invalid User!. It means that the typed username is wrong and/or not present in the equipment user listor that the user password is wrong.

The equipment is update protected by element manager, retry to login as Read Only user. It meansthat the equipment is managed also by the NMS5UX/NMS5UX-B/NMS5LX supervisory system and theNMS5UX user has prevented the possibility, for the SCT/LMT user, to be able to execute the login ofthe equipment. In this case, it is necessary that the NMS5UX user enables again the SCT/LMT user forthe execution of the operation.

Too many WEB users!. It means that the equipment has been connected to the maximum number ofallowed users (see Limits).

Compatibility issue found. The Equipment software version is greater/lower than WebLct version. Thismay cause unpredictable problems, means that the firmware version present on the equipment is notcompatible with the version of WEB LCT. Update the firmware of the equipment.

This is a split mount version, software download and factory default are the only operations allowed.The equipment you wish to connect to is an ALFOplus80 in version Spit Mount not Full Outdoor. Thesystem opens the WEB LCT page. The only available operations are Update the firmware of the equip-ment, Update the WEB LCT application and Restore Factory Default of the equipment.

When the WEB LCT page is open, self-explanatory messages are usually displayed about the result of anoperation or the impossibility to carry out an action because of the incongruence of the selected parame-ters.Moreover, one of the following messages can be displayed:

SYSTEM OFFLINE. The equipment is in disconnected status. In this condition, the parameters cannotbe verified/modified. The browser sends the command of reconnection at regular intervals (timeout: 20 seconds) until whenthe equipment returns in connected status or the WEB LCT page is closed. The Status parameter indi-cates the operation in progress:

• Wait next attempt. The equipment has not replied to the first reconnection attempt. When time-out is expired, the browser will attempt again.

• Reconnection failed. The equipment has not replied to next reconnection attempts. When time-out is expired, the browser will attempt again.

• Reconnection in progress. The equipment is transmitting the re-connection command. The Info: New attempt in... parameter indicates the period (expressed in seconds) between a connec-tion attempt and the next one. In any moment, it is possible to execute an immediate connection at-tempt, pressing Retry.

WARNING. Access enabled only for SYSTEM users. The selected command is available only to the userwith profile System.

You are forcing a manual operation. Operation timeout: <value>. The setting you wish to execute is amanual operation subjected to timeout.For each equipment, a timeout can be set after which the relevant active manual operations are auto-matically deactivated. The wording No Timeout indicates that the timeout is disabled; this means thata manual operation remains active until when the user deactivates it.

Loading... The request of data is in progress between the PC and the equipment

Updating..., Applying Changes... The sending of data is in progress between the PC and the equipment.

Operation Fail! Unable to Get or Update parameter(s). Wrong user profile or not logged yet! The oper-ation cannot be executed because the user profile in use is not enabled to execute the action or is notlogged to the equipment yet.

Not Implemented Yet!. The command is not available for the current version of the program.

The command is rejected to save system reachability. The operation is rejected not to compromise thesystem reachability. Verify that the made settings are compatible with the management configurationset for the equipment (see Management configurations (info).

Page 33: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 31

MENU AND COMMANDS (EQUIPMENT MENU)

Main. It manages the general equipment parameters: supervision ports configuration, Routing Table,Performance Monitoring measures, etc.Equipment. It manages the equipment general configuration.Synchronisation. It manages the sources and the outputs of synchronism.Base Band. It manages the base band parameters.Radio Branch. It manages the radio parameters.Maintenance. It manages the loops, Radio BER, LAN statistics, RMON counters, etc.

The description of every single command indicates the status of login/user profile (User Profile parameter)necessary to use the command itself or execute the relevant procedures.

Page 34: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

32 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

MAIN

Equipment Properties. It manages the properties (identifier, addresses, reference date/time, etc.) andexecutes the equipment software reset.Port Configuration. It manages the network address and the supervision parameters of the equipment.Routing Table. It manages the static Routing Table and the Default Gateway address currently used bythe equipment (Running Routing Table and Running Default Gateway).Stored Routing Table. It manages the static Routing Table and the Default Gateway address stored inthe equipment (Stored Routing Table and Stored Default Gateway).Performance Monitoring. It manages the Performance Monitoring measures.Report & Loggers Maint. It saves to file the equipment configuration, the status/alarm signals and theoperations executed by the users.SNTP & Wake Up Config. It manages the automatic acquisition of the reference date/time of the equip-ment from a network element and the Wake Up trap.Software Info & Maint. It manages the equipment firmware, the WEB LCT software present in the equip-ment, the communication stack used by the equipment and the restore of the default equipment set-tings.Backup/Restore Config. It manages the backup/restore from file of the whole equipment configuration.Alarm Severity Config. It manages the alarm transmission and their severity level.User Manager. It manages the list of the equipment users.

Page 35: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 33

Equipment Properties

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Equipment Properties command allows managing the equipment properties and executing the soft-ware reset.In detail, the command allows:

GENERAL INFO

Verify the equipment properties (type, ID, SNMP IP address, etc.)Modify the equipment identifierModify the IP address of the SNMP agent of the equipmentAlign the reference date/time of the equipment to the current date/time of the PC

EQUIPMENT ADDRESSES

Verify the equipment addresses

EQUIPMENT FEATURES

Verify the functionalities enabled for the equipmentEnable the new functionalities

EQUIPMENT UNITS

Verify the equipment units

SOFTWARE RESET

Execute the equipment software reset

The selection of the command displays the Equipment Properties contextual area

Verify the equipment properties (type, ID, SNMP IP address, etc.)

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Equipment Properties.The General Info tab displays the equipment general properties.

Modify the equipment identifier

User Profile | Station Operator, System

1. Select Main > Equipment Properties.

2. Press Change at the side of the Equipment ID parameter.

3. Type an alphanumeric string with minimum 1 and maximum 31 characters.

4. Press Apply and confirm.

Modify the IP address of the SNMP agent of the equipment

User Profile | Station Operator, System

1. Select Main > Equipment Properties.

Page 36: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

34 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

2. Press Change at the side of the Agent IP Address parameter.

3. Type the new IP address.

4. Press Apply and confirm.

Align the reference date/time of the equipment to the current date/time of the PC

User Profile | System

WARNING The operation could cause the logout of the user.

1. Select Main > Equipment Properties.The Equipment Date/Time parameter indicates the reference date/time of the equipment.

2. Press Align to PC time and confirm.The value present in the box Equipment Date/Time is updated by the value of one’s PC.

Verify the equipment addresses

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Equipment Properties.

2. Select the Network tab.The tab displays the following equipment addresses (Ethernet port, MAC address).

Verify the functionalities enabled for the equipment

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Equipment Properties.

2. Select the Equipment Features tab.The tab displays the functionalities enabled on demand.

Enable the new functionalities

User Profile | System

WARNING In order to enable one or more functionalities, IT IS NECESSARY to require the enabling certif-icate, represented by a file (with sfc extension), to the company that provides the equipment. For each equipment you wish to enable one or more functionalities, a specific enabling certificate is re-quired, because there is an univocal link between each single certificate and each specific equipment.

1. Select Main > Equipment Properties.

2. Select the Equipment Feature tab.

3. Press Browse.

4. Select the enabling certificate (file with sfc extension).

5. Press Open.The selected file is indicated in the File name box.

6. Press Send Certificate File.

Page 37: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 35

A message indicates the end and the result of the operation:• Operation Done. The operation has been executed with success. When the equipment is restart-

ed, the new enabled features will be available.• Invalid operation for this equipment…. The selected certificate and equipment are not compati-

ble (wrong serial number or wrong MIB version, etc.).

Verify the equipment units

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Equipment Properties.

2. Select the Equipment Units tab.The tab displays the characteristics of the equipment units.

Execute the equipment software reset

User Profile | Station Operator, System

WARNING After the reset, all the values activated before the operation result as valid ones.

1. Select Main > Equipment Properties.

2. Press Restart Equip. and confirm.

Page 38: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

36 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Equipment Properties contextual area

In the contextual area are present the:General Info tab. The tab displays the equipment properties (type, ID, SNMP IP address, firmware ver-sion, WEB LCT ID and version, date/time, communication stack)Network tab. The tab displays the equipment addresses (Ethernet port, MAC address).Equipment Features tab. The tab displays the functionalities enabled for the equipment.Equipment Units tab. The tab displays the equipment units.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Restart Equip. Execute the equipment software resetHelp. Open the help on-line.

General Info tab

The tab displays the general equipment parameters.

Equipment Type. Equipment type.

Equipment ID. Equipment identifier. Select the Change option Modify the equipment identifier.

Agent IP Address. IP Address assigned to the agent SNMP of the equipment. Select the Change optionModify the IP address of the SNMP agent of the equipment.

Firmware Version. File name and version of the equipment firmware present on the memory benchin use.

WEB LCT Version. WEB LCT ALFOplus80 version present into the equipment.

WEB LCT Product Code. Identification code of the WEB LCT ALFOplus80 application present into theequipment.

Equipment Date/Time. Reference date/time of the equipment. Select the Align to PC time optionAlign the reference date/time of the equipment to the current date/time of the PC. The format of date/time changes according to the setting made in the operating system.

IP/OSI Stack. Communication stack in use.

Related TopicsUpdate the firmware of the equipmentUpdate the WEB LCT application

Network tab

The tab displays the following equipment addresses:

Ethernet IP Address. IP Address of the communication port with the LAN network (Ethernet port).

Ethernet IP NetMask. Mask for the network address definition of the Ethernet port.

Ethernet MAC Address. Physical address of the equipment.

Related TopicsVerify/modify the network address and the supervision parameters of the equipment

Page 39: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 37

Equipment Features tab

The tab displays the list of the equipment functionalities enabled on demand.

Upgrade up to 4QAM. Maximum equipment modulation up to 4QAM.

Upgrade up to 750M. Channel spacing up to 750M.

Upgrade up to 1000M. Channel spacing up to 1000M.

1+0 Stand alone configuration. Enabling of stand-alone (without IDU) operation of the equipment.

1+1 Stand alone configuration. Enabling of stand-alone (without IDU) operation of the equipmentin protected configuration.

Radio payload Encryptions. Protection of radio data through encryption algorithm.

Eth transport. Enabling of Ethernet transport.

Eth OAM. OAM-FM feature for Ethernet network.

SyncE. Use of Ethernet synchronism sources.

SSM G8264 (quality sync). Management of synchronisation quality.

OSPF. Management of OSPF routing protocol.

1588 support. Enabling of PTP IEEE1588 protocol for the synchronisation of Ethernet traffic.

packet processor (1). Optional Ethernet processing.

packet processor (2). Optional Ethernet processing.

Enhanced eth monitoring. Monitoring of enhanced Ethernet.

G8032 (Eth ring protection). Protection of the Ethernet traffic in a ring topology.

Security package (+SSH + SFTP). Protected access to the unit for management purposes.

For every functionality, the relevant enabling status is pointed out:Enabled. The functionality is enabled.Disabled. The functionality is not enabled.

Related TopicsEnable the new functionalities

Equipment Units tab

The table present in the tab, displays the characteristics of the equipment unitsEvery row of the table corresponds to an unit for which is displayed in the column:

Real Type. Unit type really present into the equipment. The wording Unequipped indicates that theunit is not physically present into the equipment.

Expected Type. Foreseen unit type. The wording Unequipped indicates that the unit is not foreseen.

HW Ver. Unit version.

Part Number. Part Number of the unit.

Par. Part Num. Part Number of the group that contains the unit. Usually the group represents theequipment part that can be replaced. Not all the unit are into a group. In this case the field will resultempty and the part that can be replaced will correspond to the unit itself.

Serial Number. Series Number of the group that contains the unit. If the unit is not contained into agroup (Par Part Num field empty), the Series Number refers to the unit.

Unit Alarms. Functional status of the unit. Each box identifies an alarm:• Fail. The units is affected by a serious malfunctioning.• Missing. The unit is not present in the equipment (Unequipped wording - Real Type param-

eter) even if foreseen (unit name - Expected Type parameter).

Page 40: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

38 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Not Resp. The unit does not answer to the program interrogations.• HW Mism. The real unit (Real Type parameter) is different from the foreseen one (Expected

Type parameter). • SW Mism. The firmware version present into the controller of the peripheral unit (Actual Re-

lease) is different from the one of the memory bench in Running status (Release Bench...)(see Verify the firmware version of the equipment).

The colour of the boxes represents the alarm status and severity:• Red, Orange, Yellow, Light blue. Alarm active, respectively of Critical, Major, Minor, Warning

severity.• Green. Alarm active with Status severity level.• White. Alarm deactivated.

Page 41: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 39

Port Configuration

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The command Port Configuration manages the network address and the supervision parameters of theequipment and allows resetting the equipment software.In detail, the command allows:

SUPERVISION PARAMETERS

Verify/modify the network address and the supervision parameters of the equipmentRestore the access to equipment CPU

SOFTWARE RESET Execute the equipment software reset

The selection of the command displays the Port Configuration contextual area

In order to deepen this topic, see Management configurations (info)

Verify/modify the network address and the supervision parameters of the equipment

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The management configuration allowed for the equipment are shown in Tab.1.

1. Select Main > Port Configuration.The Ethernet tab displays the IP address and the supervision parameters of the equipment:

• IP Address. IP address of the communication port with the LAN network.To change the parameter, type the new IP address in the box.The typed number has to be compatible with the setting of the relevant Net Mask field.

• Net Mask. Mask for the network address definition. To change the parameter, type the new value in the box.

• LAN 1. Activation status of the supervision on the LAN 1:• Disabled. The supervision is not active.• In Band. The in band supervision is active. In this case, the parameter In Band VLan Id

must be configured.To change the parameter, select the wished value in the box.

• LAN 2. Activation status of the supervision on the LAN 2:• Disabled. The supervision is not active.• Local Access Only. LAN 2 can access only to local controller. The supervision network is

not connected to radio side.• In Band. The in band supervision is active. In this case, the parameter In Band VLan Id

must be configured.• Out Of Band. Out Of Band supervision is active.• Drop Node. The port is reserved to the supervision and represents a point for the access

to the supervision network over the traffic.• In Band VLan Id. VLAN identifier reserved for in band supervision.

When in band supervision is active (at least one LAN box set to In Band) IT IS NECESSARY toreserve a VLan for this management.To change the parameter, set a value between 1 and 4095. The activation of In Band Manage-ment is immediately achieved by the activation of the box relevant to a port (restart is not nec-essary).Entering a value of In Band VLan Id already present in the VLAN table causes the display of aproper warning message.

Page 42: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

40 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

2. Press Apply and confirm. If the displayed message is:

• The command is rejected to save system reachability. The operation is rejected not to compro-mise the system reachability. Verify that the made settings are compatible with the manage-ment configuration set for the equipment (see Tab.1).

• Warning: when you enable In Band management, In Band VLan ID should be different from both101 and 102. Continue anyway? The value 101 or 102 has been set as VLan ID reserved for thein band supervision. These values should not be used with the set supervision scheme. Press:

• Yes and confirm if you wish, however, to use the value.• No if you wish to cancel the operation.

• In Band VLan Id is used as port default VID. Continue anyway?. A value already used as defaultVLAN ID of a port has been set as VLan ID reserved for the in band supervision. Press:

• Yes and confirm if you wish, however, to use the value.• No if you wish to cancel the operation.

3. Press Store and confirm.

4. Press Restart and confirm.

Restore the access to equipment CPU

User Profile | Station Operator, System

1. Connect to the equipment through the console port (round power supply connector) with the followingsettings:

• Rate: 115200 baud/sec• Parity bit: none• 8 data bits• 1 stop bit

2. Open a terminal window.

3. Login with the credentials (username and password) of WEB LCT.

4. Type the command: lao The following access modality is restored:

• LAN 1: Disable • LAN 2: Local Access Only

Execute the equipment software reset

User Profile | Station Operator, System

WARNING After the reset, all the values activated before the operation result as valid ones.

1. Select Main > Port Configuration.

2. Press Restart and confirm.

Page 43: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 41

Port Configuration contextual area

In the contextual area is present the:Ethernet tab. The tab displays the IP address and supervision parameters of the equipment.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Restart. Execute the equipment software reset.Store. Store the values into the equipment controller.Retrieve. Read again the values set into the equipment controller.Help. Open the help on-line.

Ethernet tab

The tab displays the equipment IP address and supervision parameters of the equipment.

IP Address. IP address of the communication port with the LAN network.

Net Mask. Mask for the network address definition.

LAN 1. Activation status of the supervision on the LAN 1:• Disabled. The supervision is not active.• In Band. The in band supervision is active. In this case, LAN 1 must have option 802.1Q en-

abled in order to properly manage the single VLAN’s and the parameter In Band VLan Id mustbe configured.

LAN 2. Activation status of the supervision on the LAN 2:• Local Access Only. LAN 2 can access only to local controller. The supervision network is not

connected to radio side.• In Band. The in band supervision is active. In this case, LAN 2 must have option 802.1Q en-

abled in order to properly manage the single VLAN’s and the parameter In Band VLan Id mustbe configured.

• Out Of Band. Out Of Band supervision is active.• Drop Node. The port is reserved to the supervision and represents a point for the access to

the supervision network over the traffic.

In Band VLan Id. VLAN identifier reserved for in band supervision.

Related TopicsManagement configurations (info)

Page 44: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

42 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Management configurations (info)

The ports of the Ethernet Switch of ALFOplus80 equipment can be configured for the transport of the trafficonly or for the contemporary transport of traffic and supervision.For the transport of the supervision, the traffic Ethernet interfaces use a logic separation, based on VLANTag (In Band Management), or a physical independence avoiding that the traffic shares this interface (OutOf Band Management). The available management configurations are reported in Tab.1. Setting a specificmanagement configuration introduces some restrictions on the setting of the Ethernet Switch parameters(see Limitations in the configuration of the Ethernet Switch).

WARNING In case of wrong configuration relevant to Ethernet management settings, the access to theequipment CPU can be restored (see Restore the access to equipment CPU).

Tab.1 - Management configurations (ALFOplus80)

Management configuration Characteristics

LAN 1 LAN 2

Disabled Local Access Only

The purpose of this configuration is to enable one port only to traffic and the other port only to thesupervision of the local unit.The supervision transits only through LAN2 (Untagged).The traffic transits only through LAN1 (Tagged/Untagged).From LAN2 it is possible to reach only the local CPU. The local CPU cannot be reached from Radio port.

Out of Band The purpose of this configuration is to enable one port only to traffic and the other port only to thesupervision.The supervision transits only through LAN2 (Untagged) (out of band supervision active).The traffic transits only through LAN1 (Tagged/Untagged).The whole network can be reached from LAN2 and from the Radio port.

In Band Not available

Disabled Not available

Drop Node Not available

In Band Local Access Only

The purpose of this configuration is to enable one port only to traffic with a management VLAN associ-ated. The other port is reserved to the local access.The supervision transits both through LAN1 (Tagged) and LAN2 (Untagged).The traffic transits only through LAN1 (Tagged/Untagged).The whole network can be reached from LAN1 and from the Radio port. From LAN2 only the local CPUcan be reached.

Drop Node The purpose of this configuration is to enable one port only to traffic and to a supervision VLAN. Thesecond port is reserved to the supervision and represents a point for the access to the supervision net-work over the traffic.The supervision transits both through LAN1 (Tagged/Tag=In Band VLan ID) and from LAN2 (Un-tagged).The traffic transits only through LAN1 (Tagged/Untagged).The whole network can be reached from LAN1, LAN2 and the Radio port.

In Band The purpose of this configuration is to enable two traffic ports with a supervision VLAN associated toboth of them. There is visibility among all the ports (bridge) on all the VLAN’s.The supervision transits both through LAN1 (Tagged/Tag=In Band VLan ID) and from LAN2 (Tagged/Tag=In Band VLan ID).The traffic transits both from LAN1 and LAN2.The whole network can be reached from LAN1, LAN2 and the Radio port.

Disabled The purpose of this configuration is to enable two traffic ports: a supervision VLAN is associated onlyto the first port. There is visibility among all the ports (bridge) on all the VLAN’s, except for supervisionone.The supervision transits only through LAN1 (Tagged/Tag=In Band VLan ID).The traffic transits both from LAN1 and LAN2. The whole network can be reached from LAN1 and from the Radio port.

Out of Band Not available

Page 45: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 43

Routing Table

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING When all the equipment belongs to the same IP network and sending packets to other networksis not necessary, the Routing Table and the address of the Gateway equipment must not be necessarilydefined because the network can manage its own internal traffic.Setting the Routing Table and Default Gateway is necessary when equipment must send packets betweentwo different networks, then the traffic must be re-routed from a network to another one (routing func-tionality of the equipment).

The Routing Table command manages the static Routing Table and the Default Gateway address current-ly used by the equipment (Running Routing Table and Running Default Gateway).In detail, the command allows:

Verify the Routing Table and the Default Gateway used by the equipmentAdd an element to the Routing TableRemove one or more elements from the Routing TableSet/modify the IP Address used as Default GatewayDelete the IP Address used as Default Gateway

The selection of the command displays the Routing Table contextual area

In order to deepen this topic, see Routing Table and Default Gateway (info)

Verify the Routing Table and the Default Gateway used by the equipment

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Routing Table.The Routing Table contextual area displays the setting of the static Routing Table and the Default Gate-way address currently used by the equipment (Running Routing Table and Running Default Gateway).

Add an element to the Routing Table

User Profile | Station Operator, System

1. Select Main > Routing Table.

2. Press Add.

3. Into the Destination box, type the IP Address of the IP network or of the destination element.

4. Into the NetMask box, type the mask for the destination IP network

5. Into the Hop box, type the IP Address of the equipment acting as Gateway for the destination network.

6. Press Apply.The new element is inserted into the table. The system records the new element into the currently usedRouting Table (Running Routing Table) and into the backup memory of the equipment (Stored RoutingTable).

Page 46: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

44 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Remove one or more elements from the Routing Table

User Profile | Station Operator, System

1. Select Main > Routing Table.

2. Select the element of the Routing Table.Multiple selections can be executed using the Ctrl or Shift keys.Items automatically inserted by the controller (items with Local protocol) cannot be deleted.

3. Press Remove and confirm.The system deletes the element into the currently used Routing Table (Running Routing Table) and intothe backup memory of the equipment (Stored Routing Table).

Set/modify the IP Address used as Default Gateway

User Profile | Station Operator, System

1. Select Main > Routing Table.

2. Into the Default Gateway box, type the IP Address of the equipment used as Default Gateway.In the next box is automatically indicates the supervision port which the IP address of the Gatewayequipment corresponds to.

3. Press Apply (next to Delete push-button) and confirm.The system inserts the new Default Gateway IP address into the currently used Routing Table (RunningRouting Table) and into the backup memory of the equipment (Stored Routing Table).The insertion of a new IP address used as Default Gateway can fail if the new IP address does not belongto an IP network directly connected to the equipment interface.

Delete the IP Address used as Default Gateway

User Profile | Station Operator, System

1. Select Main > Routing Table.

2. Press Delete and confirm.The system deletes the Default Gateway IP address into the currently used Routing Table (RunningRouting Table) and into the backup memory of the equipment (Stored Routing Table).

Page 47: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 45

Routing Table contextual area

The contextual area shows the setting of the static Routing Table and the Default Gateway address cur-rently used by the equipment (Running Routing Table and Running Default Gateway).

The table represents the Running Routing Table. Each row of the table corresponds to an item of the Rout-ing Table. For every item, is pointed out in the column:

Destination. IP address of the IP network or of the destination element.

Net Mask. IP NetMask of the IP network or of the destination element.

Hop. IP address of the equipment that acts as Gateway.

Interface. Supervision port of the local equipment which the Gateway equipment is connected to:• Lan. Communication port with the LAN network.• <no wording>. Inner port (internal loopback).

Protocol. Modality of connection (direct or indirect) between specific port (Interface) and destinationIP network:

• Local. The IP network or the element are directly connected to the equipment interface. TheIP network or the element are automatically inserted by the equipment software.

• NetMgmt. The IP network or the element are not directly reachable from the equipment in-terfaces. The IP network or the element have been manually inserted by the user (static el-ement).

• Other. All the other situations not falling in one of the previous cases (this label generallydoes not shown; it has been anticipated for future uses).

The Default Gateway parameter indicates the IP address of the equipment that acts as Running DefaultGateway. The following box indicates the supervision port which the IP address of the Gateway equipmentcorresponds to.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on-line.

Add. Add an element to the Routing Table.Remove. Remove one or more elements from the Routing Table.Apply. Set/modify the IP Address used as Default Gateway.Delete. Delete the IP Address used as Default Gateway.

Related TopicsRouting Table and Default Gateway (info)

Page 48: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

46 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Routing Table and Default Gateway (info)

Routing TableRunning Routing TableStored Routing TableDefault Gateway

Routing Table

The function of the Routing Table is the one to check the routing of the supervisory messages exchangedamong the elements (PCs, equipment, etc.), that use the TCP/IP protocol, from one network to the otherone.

Running Routing Table

Each equipment at its initialisation (start-up operation) automatically sets the elements of the Routing Ta-ble that identify the supervisory ports of the equipment (communication ports provided with the equipmentfor the input/output of the supervisory signal).These elements are set according to the IP addresses assigned to each port. If the user changes the IP address of a supervisory port, the system does not dynamically change it intothe equipment Routing Table. The equipment must be reset, because the elements of the Routing Tableare set at the equipment start-up.If necessary, the user can add some other elements to these ones (automatically set).The system records each new element (manually set) into the currently used Routing Table (Running Rout-ing Table) and into the backup memory of the equipment controller (Stored Routing Table); the systemdoes not record the elements (automatically set) into the backup memory of the controller because theyare newly set at every equipment start-up.The Running Routing Table is a static. The system updates this table, with the elements present in theStored Routing Table, at every equipment start-up.

Stored Routing Table

The equipment does not currently use the Stored Routing Table. This table becomes operative on theequipment restart.In fact, in this case, the system inserts the elements of the Stored Routing Table into the Routing Tableused by the equipment (Running Routing Table). What just said is valid only for the elements whose routerequipment (Hop) is associated to an active interface.The setting of the Stored Routing Table id necessary, for instance, when the user wants to change an ad-dress of the equipment supervisory ports.In this case, the currently used Routing Table (Running Routing Table) cannot be changed.The changes have to be inserted into the Stored Routing Table. At the next equipment start-up, the systeminserts the elements of the Stored Routing Table into the Routing Table used by the equipment.

Default Gateway

The system forwards to the equipment with the Default Gateway function the data that have a receiverunreachable through the routes present into the Routing Table.

Page 49: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 47

Stored Routing Table

User Profile | System

The Stored Routing Table command manages the static Routing Table and the Default Gateway addressstored in the equipment (Stored Routing Table and Stored Default Gateway).In detail, the command allows:

Verify the Routing Table and the Default Gateway present into the backup memory of the controllerAdd an element into the Stored Routing TableRemove one or more elements from the Stored Routing TableSet/modify the IP Address used as Default Gateway into the Stored Routing TableDelete the IP address used as Default Gateway into the Stored Routing Table

The selection of the command displays the Stored Routing Table contextual area

In order to deepen this topic, see Routing Table and Default Gateway (info)

Verify the Routing Table and the Default Gateway present into the backup memory of the controller

User Profile | System

1. Select Main > Stored Routing Table.The Stored Routing Table contextual area displays the setting of the static Routing Table and the De-fault Gateway address present in the backup memory of the equipment controller (Stored Routing Tableand Stored Default Gateway).

Add an element into the Stored Routing Table

User Profile | System

1. Select Main > Stored Routing Table.

2. Press Add.

3. Into the Destination box, type the IP Address of the IP network or of the destination element.

4. Into the NetMask box, type the mask for the destination IP network

5. Into the Hop box, type the IP Address of the equipment acting as Gateway for the destination network.

6. Into the Interface box, set the supervisory port of the local equipment which the Gateway equipmentis connected to:

• Lan. Communication port with the LAN network.

7. Press Apply.The system inserts the new element into the table.

8. Press Save and confirm.The system saves the new element into the backup memory of the equipment.The system records the new element ONLY into the backup memory of the equipment (Stored RoutingTable). At the next equipment start-up, the system will insert this new element also in the current rout-ing table (Running Routing Table). What just said is valid only for the elements whose equipment (Hop)is associated to an active interface.

Page 50: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

48 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Remove one or more elements from the Stored Routing Table

User Profile | System

1. Select Main > Stored Routing Table.

2. Select the element of the Stored Routing Table.Multiple selections can be executed using the Ctrl or Shift keys.

3. Press Remove and confirm.

4. Press Save and confirm.The system removes the element from the backup memory of the equipment.The system deletes the element ONLY from the backup memory of the equipment (Stored Routing Ta-ble). At the next equipment start-up, the system will delete this element even in the current RoutingTable (Running Routing Table).

Set/modify the IP Address used as Default Gateway into the Stored Routing Table

User Profile | System

1. Select Main > Stored Routing Table.

2. Into the Default Gateway box, type the IP Address of the equipment used as Default Gateway.

3. Into the next box, set the supervision port which the IP address of the Gateway equipment correspondsto:

• Lan. Communication port with the LAN network.

4. Press Apply (next to Delete push-button) and confirm.

5. Press Save and confirm.The system saves the new IP address of Default Gateway into the backup memory of the equipment.The system records the IP address of Default Gateway ONLY into the backup memory of the equipment(Stored Routing Table). The equipment will display this IP address only at the next restart of the equip-ment.

Delete the IP address used as Default Gateway into the Stored Routing Table

User Profile | System

1. Select Main > Stored Routing Table.

2. Press Delete and confirm.

3. Press Save and confirm.The system removes the IP address of Default Gateway from the backup memory of the equipment.

Page 51: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 49

Stored Routing Table contextual area

The contextual area shows the setting of the static Routing Table and the Default Gateway address presentin the backup memory of the equipment controller (Stored Routing Table and Stored Default Gateway).

The table represents the Stored Routing Table. Every row of the table corresponds to an element of theRouting Table. For every element, is pointed out in the column:

Destination. IP address of the IP network or of the destination element.

Net Mask. IP NetMask of the IP network or of the destination element.

Hop. IP address of the equipment that acts as Gateway.

Interface. Supervision port of the local equipment which the Gateway equipment is connected to:• Lan. Communication port with the LAN network.

The Default Gateway parameter indicates the IP address of the equipment that acts as Stored DefaultGateway. The next box indicates the supervision port which the IP address of the Gateway equipment cor-responds to.

Push-button:Apply. Not available in this context.Refresh. Read again the data from the memory of the equipment after a Retrieve command. For in-stance, if the user wants updating the Stored Routing Table displaying the elements manually addedby the user into the Running Routing Table, he has to press Retrieve and later the Refresh one.Help. Open the help on-line.

Add. Add an element into the Stored Routing Table.Remove. Remove one or more elements from the Stored Routing Table.Retrieve. Read again the data from the backup memory and load them into the equipment memory.Save. Save the elements of the table into the backup memory of the equipment.Apply. Set/modify the IP Address used as Default Gateway into the Stored Routing Table.Delete. Delete the IP address used as Default Gateway into the Stored Routing Table.

Related TopicsRouting Table and Default Gateway (info)

Page 52: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

50 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Performance Monitoring

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Performance Monitoring command manages the Performance Monitoring measures.In detail, the command allows:

Verify the status, the results and the threshold exceeding alarms of a PM measureActivate one or more PM measuresDeactivate one or more PM measuresReset the threshold exceeding alarms of one or more PM measuresReset the values of the records daily and primary of one or more PM measuresSet the thresholds of the control parameters and alarms of a PM measure

The selection of the command displays the Performance Monitoring contextual area

In order to deepen this topic, see:Measures available for ALFOplus80 equipmentPM measures (info)

Verify the status, the results and the threshold exceeding alarms of a PM measure

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.The Performances [none selected] window displays the PM measures. The measures are subdivided in groups. The group and the relevant measures (group > measure) available for the ALFOplus80 equipment arethe following:

G828 > Radio 1A, checks the quality of the received signal at radio side. RxPwr > Radio 1A, checks the power of the signal at reception.TxPwr > Radio 1A, checks the power of the signal at transmission.

3. Select the group that contains the measure and than the wished measure.For every measure is pointed out the status:

• (Stop.). The measure is not on progress.• (Run.). The measure is on progress.

Below the measure, more options are pointed out: seconds, blocks, Rlts, etc. depending on the type ofselected measure.Every option indicates the measurement unit of the control parameters for which you wish to displaythe results and the threshold exceeding alarms.This subdivision is necessary because the results of the control parameters cannot be graphically dis-played by means of different measurement units.

4. Select the wished measuring unit.The Performances [group / measure / measurement unit] window displays the results of the controlparameters, in graphic and table format, and the status of the threshold exceeding alarms.If the measurement has never been activated, the window will result empty.The items in the Performances window are described in Fig.4.

It is possible to open more Performances... window pressing again Open new performance windowor pressing Open New Window present in the Performances.... window itself.

Page 53: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 51

Activate one or more PM measures

User Profile | Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.

3. To activate:• All measures in a group, select the group.• Single measure, select the group that contains the measure and than the wished measure.

4. Press Start and confirm.The not active measure(s) are started and their status passes from (Stop.) to (Run.).

Deactivate one or more PM measures

User Profile | Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.

3. To deactivate:• All measures in a group, select the group.• Single measure, select the group that contains the measure and than the wished measure.

4. Press Stop and confirm.The active measure(s) are stopped and their status passes from (Run.) to (Stop.).

Reset the threshold exceeding alarms of one or more PM measures

User Profile | Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.

3. To reset the threshold exceeding alarms of:• All measures in a group, select the group.• Single measure, select the group that contains the measure and than the wished measure.

4. Press Clear Alarms and confirm.For the selected measure, active alarms are deactivated except for the unavailability alarms.

Reset the values of the records daily and primary of one or more PM measures

User Profile | Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.

3. To reset the values of the records daily and primary of:• All measures in a group, select the group.• Single measure, select the group that contains the measure and than the wished measure.

4. Press Clear Counters and confirm.The values displayed into table are reset.

Page 54: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

52 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Set the thresholds of the control parameters and alarms of a PM measure

User Profile | Station Operator, System

1. Select Main > Performance Monitoring.

2. Press Open new performance window.

3. Select the group that contains the measure and than the wished measure.

4. Press Commons.

If G828 > Radio 1A measure is selected, the Commons window displays the following parameters:• General area. Threshold levels of the UAS and SES parameters:

• N Ses Set UAS(P) (sec.). Threshold (expressed as number of consecutive seconds withSES) over which starts the UAS unavailability period.To change the parameter set a value between 1 and 10 sec (default 10), press Applyand confirm.

• N Ses Reset UAS(Q) (sec.). Threshold (expressed as number of consecutive secondswithout SES) over which ends the UAS unavailability period.To change the parameter set a value between 1 and 10 sec (default 10), press Applyand confirm.

• N BBE Set Ses (%.). Threshold (expressed as percentage of the errored blocks) overwhich it is declared a SES.To change the parameter set a value between 1 and 100% (default 30%), press Applyand confirm.

Press to compress the area. Press to expand the area.• 15M Es Threshold (sec.). Threshold (expressed as number of seconds, within a 15 minute peri-

od, when ES has occurred) over which it is activated the alarm 15M Es.To change the parameter set a value between 1 and 900 (default 0), press Apply and confirm.The value 0 represents the deactivation of the threshold and accordingly of the alarm.

• 24H Es Threshold (sec.). Threshold (expressed as number of seconds, within a 24 hour period,when ES has occurred) over which it is activated the alarm 24H Es.To change the parameter set a value between 1 and 86400 (default 0), press Apply and con-firm. The value 0 represents the deactivation of the threshold and accordingly of the alarm.

• 15M Ses Threshold (sec.). Threshold (expressed as number of seconds, within a 15 minute pe-riod, when SES has occurred) over which it is activated the alarm 15M Ses.To change the parameter set a value between 1 and 900 (default 0), press Apply and confirm.The value 0 represents the deactivation of the threshold and accordingly of the alarm.

• 24H Ses Threshold (sec.). Threshold (expressed as number of seconds, within a 24 hour period,when SES has occurred) over which it is activated the alarm 24H Ses.To change the parameter set a value between 1 and 86400 (default 0), press Apply and con-firm. The value 0 represents the deactivation of the threshold and accordingly of the alarm.

• 15M Sep Threshold (events). Threshold (expressed as number of SEP events within a 15 minuteperiod) over which it is activated the alarm 15M Sep.To change the parameter set a value between 1 and 900 (default 0), press Apply and confirm.The value 0 represents the deactivation of the threshold and accordingly of the alarm.

• 24H Sep Threshold (events). Threshold (expressed as number of SEP events within a 24 hourperiod) over which it is activated the alarm 24H Sep.To change the parameter set a value between 1 and 86400 (default 0), press Apply and con-firm. The value 0 represents the deactivation of the threshold and accordingly of the alarm.

If RxPwr > Radio 1A measure is selected, the Commons window displays the following parameters:• 15M Rlts Thresholds area. 15M Rlts alarms threshold:

• Rlts 1 (sec.), Rlts 2 (sec.), Rlts 3 (sec.), Rlts 4 (sec.), Rlts 5 (sec.). Threshold levels (ex-pressed as number of seconds, within a 15 minute period, when the received power islower than the RLT1, RLT2, RLT3, RLT4, RLT5 threshold levels) over which the systemactivates the relevant alarms.To change a threshold, set into the relevant box, a number between 1 and 900 (default0), press Apply and confirm. The value 0 represents the deactivation of the thresholdand accordingly of the alarm.

• 24H Rlts Thresholds area. 24H Rlts alarms threshold:

Page 55: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 53

• Rlts 1 (sec.), Rlts 2 (sec.), Rlts 3 (sec.), Rlts 4 (sec.), Rlts 5 (sec.). Threshold levels (ex-pressed as number of seconds, within a 24 hour period, when the received power is lowerthan the RLT1, RLT2, RLT3, RLT4, RLT5 threshold levels) over which the system activatesthe relevant alarms.To change a threshold, set into the relevant box, a number between 1 and 86400 (default0), press Apply and confirm. The value 0 represents the deactivation of the thresholdand accordingly of the alarm.

• Rlt Thresholds area. Threshold levels of the received power:• Rlt 1 (dBm), Rlt 2 (dBm), Rlt 3 (dBm), Rlt 4 (dBm), Rlt 5 (dBm). Respectively the first,

the second, the third, the fourth and the fifth threshold level of the received power.To change a threshold, set into the relevant box, a number between -100dBm and -20dBm. Default: Rlt 1: -30 dBm, Rlt 2: -40 dBm, Rlt 3: -50 dBm, Rlt 4: -60 dBm, Rlt 5:-70 dBm.

Press to compress an area. Press to expand the area.

If TxPwr > Radio 1A measure is selected, the Commons window displays the following parameters:• 15M Tlts Thresholds area. 15M Tlts alarms threshold:

• Tlts 1 (sec.), Tlts 2 (sec.), Tlts 3 (sec.), Tlts 4 (sec.). Threshold levels (expressed as num-ber of seconds, within a 15 minute period, when the transmitted power is higher than theTLT1, TLT2, TLT3, TLT4 threshold levels) over which the system activates the relevantalarms.To change a threshold, set into the relevant box, a number between 1 and 900 (default0), press Apply and confirm. The value 0 represents the deactivation of the thresholdand accordingly of the alarm.

• 24H Tlts Thresholds area. 24H Tlts alarms threshold:• Tlts 1 (sec.), Tlts 2 (sec.), Tlts 3 (sec.), Tlts 4 (sec.). Threshold levels (expressed as num-

ber of seconds, within a 24 hour period, when the transmitted power is higher than theTLT1, TLT2, TLT3, TLT4 threshold levels) over which the system activates the relevantalarms.To change a threshold, set into the relevant box, a number between 1 and 86400 (default0), press Apply and confirm. The value 0 represents the deactivation of the thresholdand accordingly of the alarm.

• Tlt Thresholds area. Threshold levels of the transmitted power:• Tlt 1 (dBm), Tlt 2 (dBm), Tlt 3 (dBm), Tlt 4 (dBm). Respectively the first, the second, the

third and the fourth threshold level of the transmitted power.To change a threshold, set into the relevant box, a number between -40dBm and 35dBm,press Apply and confirm. Default: Tlt 1: 10dBm, Tlt 2: 13dBm, Tlt 3: 15dBm, Tlt 4:18dBm.

Press to compress an area. Press to expand the area.

Page 56: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

54 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Performance Monitoring contextual area

In the contextual area is present the Open new performance window push-button.Pressing it, the Performances window is displayed, which allows:

• Manage the PM measures (activation, deactivation, threshold setting).• Display the activation status of the PM measures• Display the results of the measures in graphic and table format.• Display the status of the threshold exceeding alarms.

The items of the Performances window are described in Fig.4.

It is possible to open more Performances... window pressing again Open new performance window orpressing Open New Window present in the Performances.... window itself.

Related TopicsVerify the status, the results and the threshold exceeding alarms of a PM measureActivate one or more PM measuresDeactivate one or more PM measuresReset the threshold exceeding alarms of one or more PM measuresReset the values of the records daily and primary of one or more PM measuresSet the thresholds of the control parameters and alarms of a PM measure

Measures available for ALFOplus80 equipmentPM measures (info)

Fig.4 Performances window

1

2

3 64

5

Page 57: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 55

(1) Title bar. When the window is opened, the title bar displays Performances [none selected].When you select an option which allows displaying the results of a measure ( see note 3), Perfor-mances [Selected group / Selected measure / Selected measurement unit] will be displayed, forexample Performances [G828 / Radio 1A / seconds].Push-button:

. Compress the window.

. Expand the window.

. Expand the window to the size of the Browser page

. Restore the original size of the window.

. Close the window.

(2) Push-buttons bar:Start. Activate one or more PM measures.Stop. Deactivate one or more PM measures.Clear Alarms. Reset the threshold exceeding alarms of one or more PM measures.Clear Counters. Reset the values of the records daily and primary of one or more PM measuresstored into the equipment and displayed into the window. Refresh. Update the data.Commons. Set the thresholds of the control parameters and alarms of a PM measure. Push-button meaningful only if one group is selected.Open New Window. Open a new Performances window. Help. Open the help on-line.

The push-buttons Start, Stop, Clear Alarms and Clear Counters, if a group is selected, executetheir action for all the measures present in the group. Otherwise, if one measure or one option belowthe measure is selected, they execute their action only for the selected measure.

(3) List of the PM measures. The measures are subdivided in groups. Selecting a group, the list of the measures associated to the group can be expanded.Selecting one measure, the options pointing out the measurement units of the parameters associ-ated to the measure are displayed. This subdivision is necessary because it is not possible to graph-ically represent the results of the control parameters by means of different measurement units.Selecting one measurement unit in the right part of the window (see note 4), the result of the con-trol parameters and the threshold exceeding alarms are displayed. If the measure has never beenactivated, the graph and the table will be empty.

The symbol: identifies an expanded group or measure. identifies a compressed group or measure.

identifies a measuring unit.

To every measure, the status is displayed:(Stop.). The measure is not on progress.(Run.). The measure is on progress.

The group and the relevant measures (group > measure) available for the ALFOplus80 equipmentare the following:

G828 > Radio 1A, checks the quality of the received signal at radio side.The results of the control parameters are shown subdivided into the following measuring units:

• seconds. Seconds: ES, SES, SEP, UAS.• blocks. Blocks: BBE.

RxPwr > Radio 1A, checks the power of the signal at reception.The results of the control parameters are shown subdivided into the following measuring units:

• Rlts. Seconds: Rlts1, Rlts2, Rlts3, Rlts4, Rlts5.• TM. dBm: TMMax, TMMin, Average Lev.

TxPwr > Radio 1A, checks the power of the signal at transmission.The results of the control parameters are shown subdivided into the following measuring units:

• Tlts. Seconds: Tlts1, Tlts2, Tlts3, Tlts4.

Page 58: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

56 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• TM. dBm: TMMax, TMMin, Average Lev.

Press to hide the list of measures. Press to display the list again.

(4) Graphical representation of the measure results. This area displays, in graphical format, theresults of the control parameters of the selected measure/measurement unit.Every bar represents the result of the measure of one parameter in a given observation period (dailyor primary record). The position of the bar on the x-axis indicates the daily or primary record which it is referred to:

• C.D. X100. Current daily record (24 hours). The displayed value must be multiplied by 100to obtain the real measured value.

• L. D. x100. Preceding daily record. The displayed value must be multiplied by 100 to obtainthe real measured value.

• Curr. 15 Min. Current primary record (15 minutes).• 15Min. ÷ 4 Hours. 16 preceding primary records (each record is of 15 minutes).

Moreover, for every record the relevant status is displayed: (ML), (MF), (IN), (LO), (RE). The de-scription of every single status is reported in the following note. If the status indication is not pre-sent, the record is not available, because the measure was not active during the consideredobservation period.

The colour of the bar indicates the control parameter that corresponds to the value. The key of theparameters and their colours is always pointed out above the graph. The displayed control param-eters changes according to the selected measure/measuring unit (see note 3).

The position on the y-axis indicates the value achieved by the parameter during the specific obser-vation period (record). The measurement unit on the y-axis changes depending on the type of pa-rameter represented in the graph. Moreover the y-scale dynamically changes depending on theentity of the represented values.

(5) Table representation of the measure results. This area displays, in table format, the results ofthe control parameters of the selected measure/measurement unit.For every parameter, the result of the measure is pointed out relevant to a given observation period(daily or primary record). In detail, the column:

• Type. Control parameters. The control parameters changes according to the selected meas-ure/measuring unit (see note 3).

• Curr. Day. Current daily record (24 hours).• Last Day. Preceding daily record.• Curr. 15 Min. Current primary record (15 minutes).• 15Min. ÷ 4 Hours. 16 preceding primary records (each record is of 15 minutes).

What just said is valid from the second row of the table on, because the first row indicates the statusof the records (Count. Status). In detail, the wording:

• Meaningless (ML) (green) The record has been completely acquired and the measure is notaffected by errors.

• Meaningful (MF) (green) The record has been completely acquired and the measured controlparameters have not exceeded their threshold value.

• Incomplete (IN) (yellow) The record has not been completely acquired during the corre-sponding observation period.The measure starting record is always in this status. The daily record gets this status alsowhen only one primary record of the corresponding day is in incomplete status.The daily record of the current date will be always an incomplete one because the daily re-cords are acquired at 23.59 of each day.

• Lost (LO) (red) The record has not reached the main controller of the equipment for instancebecause the corresponding peripheral card has been physically extracted before it could haveforwarded the record itself or for generic hardware/software troubles.

• Restarted (RE) (red) The record has been lost after a reset of the equipment.When the equipment has a software restart and checks that the measure is activated for acertain measure point, all the record coupled with such a measure point will result in thisstatus.

• ---. The record is not an available one because, during the observation period under exam-ination, the measure was not activated.

Page 59: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 57

(6) Status of the threshold exceeding alarms. This area displays the status of the threshold ex-ceeding alarms of the selected measure/measurement unit.Each box represents an alarm:

• 15M <control parameter>. Threshold exceeding alarm of the specific control parameter intoone of the primary observation periods (15 minutes) present into the window.

• 24H <control parameter>. Threshold exceeding alarm of the specific control parameter intoone of the daily observation periods (24 hours) present into the window.

• UAS. Unavailability alarm.

The colour of the boxes represents the alarm status and severity:• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-

jor, Minor, Warning severity.• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

The Rlt Thresh. boxes point out the threshold levels of the received power actually set. These pa-rameters can be configured by the user.

The Tlt Thresh. boxes point out the threshold levels of the transmitted power actually set. Theseparameters can be configured by the user.

Page 60: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

58 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Measures available for ALFOplus80 equipment

The measures available for the ALFOplus80 equipment are the following:G828 > Radio 1ARxPwr > Radio 1ATxPwr > Radio 1A

G828 > Radio 1A

The Radio 1A measure (G828 group) checks the quality of the received signal at radio side.The check consists of measuring the following quality parameters:

• BBE (Background Block Error). Number of blocks where it has been detected at least one er-rored bit not belonging to SES.

• ES (Errored Second). The second when there have been one or more errored blocks.• SES (Severely Errored Second). The second when there have been a percentage of errored

blocks > N% (the N value can be configured) or the second when it has been activated an alarmequivalent to the interruption of the signal at reception (Loss of Signal Alarm, Loss of FrameAlarm, B2 Excessive Ber Alarm, etc.).

• SEP (Severely Errored Period). Number of periods with a number of consecutive SES comprisedbetween 3 and 9. The sequence is ended by a second without SES.

• UAS (UnAvailable Seconds). Number of unavailability seconds.The counting of the seconds starts after P consecutive seconds with SES presence and it endsat the beginning of a period of Q consecutive seconds without SES. The P seconds are countedinto the unavailability period. The Q and P values can be configured.

The parameters are implemented according to G.828 ITU-T Rec.

RxPwr > Radio 1A

The Radio 1A measure (RxPwr group) checks the power of the signal at reception.The check consists of measuring the following quality parameters:

• TMMax (Tide Mark Max). Maximum value reached by the power at reception (RL) during theobservation period (15 min or 24 hours).

• TMMin (Tide Mark Min). Minimum value reached by the power at reception (RL) during the ob-servation period (15 min or 24 hours).

• Average Level. Average level of the power at reception (RL) during the observation period (15min or 24 hours).

• Rlts (Received Level Threshold Second). Number of seconds where it has been detected thatthe value of the power at reception (RL - Received Level) is lower than the pre-defined thresholdlevel. It is possible to define up to a maximum of 5 threshold levels.

The parameters are implemented according to Standard EN 301 129 of the ETSI.

TxPwr > Radio 1A

The Radio 1A measure (TxPwr group) checks the power of the signal at transmission.The check consists of measuring the following quality parameters:

• TMMax (Tide Mark Max). Maximum value reached by the power at transmission (TL) during theobservation period (15 min or 24 hours).

• TMMin (Tide Mark Min). Minimum value reached by the power at transmission (TL) during theobservation period (15 min or 24 hours).

Page 61: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 59

• Average Level. Average level of the power at transmission (TL) during the observation period(15 min or 24 hours).

• Tlts (Transmitted Level Threshold Second). Number of seconds where it has been detected thatthe value of the power at transmission (TL - Transmitted Level) is higher than the pre-definedthreshold level. It is possible to define up to a maximum of 4 threshold levels.

The parameters are implemented according to Standard EN 301 129 of the ETSI.

Page 62: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

60 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

PM measures (info)

A PM measure consists of recording, during a pre-defined time range (observation period), the values ofspecific parameters.Some threshold limits have been assigned to these control parameters (the setting of the thresholds canbe changed).The exceeding of the threshold limit indicates a more or less serious degradation of the signal. This condi-tion generates an alarm.The alarms relevant to the threshold exceeding are treated by the equipment and by the application asnormal alarms. The only exception is that the alarm is not automatically reset at the return into the thresh-old limit but the user has to execute the reset of this kind of alarms.The control parameters under examination change according to the equipment type and to the measuretype supported by that type of equipment. Usually, all the executed measures refer to ITU-T Recommen-dations (for instance G.828, G.826, etc.).

The activation (and the deactivation) of the PM measures can be executed only after a command forwardedby the user.When it has been activated a PM measure, the main controller of the equipment starts the storing of thevalues relevant to the control parameters. The results of the measures are sub-divided into records. Eachrecord contains the values recorded into a specific time range (observation period).If at the end of the observation period, the measure has not yet been deactivated the system starts anotherobservation period and so on until when the operator stops the measure.The equipment group the results of the PM measures into observation period of 15 minutes (primary re-cords) and of 24 hours (daily records).

The observation periods cannot be synchronized with the instant when the measure is activated, but thisrecords refer, for the primary records, to the quarter of an hour (00.00, 00.15, 00.30, etc.) and, for thedaily records, to the time 00.00 UTC (Universal Time, Coordinated).For instance, if a measure starts at 11.40, the first primary record will have as observation period the time11.40...11.45 (corresponding to the time range 11.30...11.45), while the first daily record will have as ob-servation period 11.40...00.00.

When the user requires the display of the results of the PM measures, the daily and primary records rele-vant to the running PM measures are displayed in the WEB LCT page of the equipment.

For each type of measure, the equipment keeps stored the current records and also the last 16 primaryrecords (corresponding to the last 4 hours) and the last daily one (corresponding to the preceding day).The preceding records are overwritten. When the operator stops a measure, the system stores the uncompleted current record.

If the operator activates and deactivates the measure more times during the same observation period, thesystem will store the record that contains the results of the last executed measure. For instance if the measure has been activated at 9.02 and deactivated at 9.07, then it has been newlyactivated at 9.09, the record relevant to the observation period 9.00...9.15 will contain the results of themeasures relevant to the period 9.09...9.15, while the ones relevant to the period 9.02...9.07 will not bestored.

If some PM measures are in progress on an equipment and this is restarted or turned off, at the next re-start/start-up the measures active before the turn-off will be automatically restarted. The records (primary and daily), relevant to the period when the measure has been stopped, will resultempty and when the limit of 16 primary records and 1 daily one is reached, they will overwrite the previousrecords.

Page 63: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 61

Report & Loggers Maint.

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Report & Loggers Maint. command saves to file the equipment configuration, the status/alarm sig-nals and the operations executed by the users.In detail, the command allows:

Save the configuration, the alarms and the operations executed by the users to fileDelete the alarms stored into the equipment controllerDelete the operations list stored into the equipment controller

The selection of the command displays the Report & Loggers Maint contextual area

Save the configuration, the alarms and the operations executed by the users to file

User Profile | Read Only, Read & Write, Station Operator, System

WARNING In order to execute this operation, the display of menu bar in the browser must be active.

1. Select Main > Report & Loggers Maint.

2. Activate, in the Report Options area, the information you wish to save to file:• Inventory report. Whole equipment configuration: WEB LCT version, properties, list of units, sta-

tus/version of the firmware, addresses, routing table, default gateway, remote equipment list,User Inputs, User Outputs, operating parameters, etc.

• Fault report. List of status/alarm signals currently active on the equipment (current alarms) andsignals stored in the equipment controller (alarm history).

• Command Log. List of the operations, executed by the WEB LCT, SCT/LMT or NMS5UX users,stored in the equipment controller.

It is possible to select one or more options. Depending on the activated options, a file will be createdcontaining the relevant data.

3. Press Generate Report.In sequence, are displayed:

• Report WEB page, where the information, which will be saved to file depending on the activatedoptions, are pointed out.

• A window displaying the save mode of the file according to the browser currently in use.

4. Follow the instructions in the window to save the file.The format, used to save the data to file, is the same displayed in the Report WEB page.

Delete the alarms stored into the equipment controller

User Profile | System

1. Select Main > Report & Loggers Maint.

2. Press Delete all alarm logger events and confirm.A message indicates the end and the result of the operation.

Page 64: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

62 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Delete the operations list stored into the equipment controller

User Profile | System

1. Select Main > Report & Loggers Maint.

2. Press Delete all command logger items and confirm.A message indicates the end and the result of the operation.

Page 65: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 63

Report & Loggers Maint contextual area

The contextual area displays the information which can be saved to file.

Inventory report. Whole equipment configuration: WEB LCT version, properties, list of units, status/version of the firmware, addresses, routing table, default gateway, remote equipment list, User Inputs,User Outputs, operating parameters, etc.

Fault report. List of status/alarm signals currently active on the equipment (current alarms) and sig-nals stored in the equipment controller (alarm history).

Command Log. List of the operations, executed by the WEB LCT, SCT/LMT or NMS5UX users, storedin the equipment controller.

It is possible to select one or more options. Depending on the activated options, a file will be created con-taining the relevant data.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on-line.

Generate Report. Save the configuration, the alarms and the operations executed by the users to fileDelete all alarm logger events. Delete the alarms stored into the equipment controllerDelete all command logger items. Delete the operations list stored into the equipment controller

Page 66: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

64 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Report WEB page

The WEB page Report, depending on the activated options, indicates:

Web LCT Version. WEB LCT ALFOplus80 version present into the equipment.

Equipment Configuration, General Preset, etc. Equipment parameters. The whole equipment pa-rameters are subdivided in groups. The format of the parameters present in each group is self-explica-tive and changes according to the type of represented data.

Command Logger. Operations list. Every record identifies an operation for which are reported:• Date/Time. Date and time when it has been executed the operation. The format of date/time

changes according to the setting made in the operating system.• Source address. IP address of the machine from which it has been executed the operation.• User. Name of the user who has executed the operation.• Object. Object to which the operation refers.• Instance. Name of the equipment instance to which the operation refers.• Value Set. Set value.

The presence of the symbol … indicates that the information is not available, because not meaningfulfor the relevant type of operation.

Current Alarm. Each record identifies a signal, for which the system reports:• Severity. Type of signal:

• Status. Status signal• Warning, Minor, Major or Critical. Alarm detected coupled respectively with the Warning,

Minor, Major or Critical severity.• Date/Time. Detection or reset date and time of the signal. The format of date/time changes ac-

cording to the setting made in the operating system.• Description. Alphanumeric string that specify the type of the signal.

Alarm Log. Alarms history. Every record identifies a signal for which is reported:• Severity. Type of signal:

• Disable. Alarm signal reset• Status. Status signal• Warning, Minor, Major or Critical. Alarm detected coupled respectively with the Warning,

Minor, Major or Critical severity.• Date/Time. Detection or reset date and time of the signal. The format of date/time changes ac-

cording to the setting made in the operating system.• Description. Alphanumeric string that specify the type of the signal. If:

• The wording CLEARED is absent, the record refers to a detected alarm.• The wording CLEARED is present, the record refers to a cleared alarm.

Page 67: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 65

SNTP & Wake Up Config.

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The SNTP & Wake Up Config. command manages the automatic acquisition of the reference date/timeof the equipment from a network element (SNTP functionality) and the Wake Up trap (Wake Up function-ality).In detail, the command allows:

Verify the status of SNTP functionalitySet the execution parameters and activate the SNTP functionalityDisable the SNTP functionalityVerify the Wake Up functionality statusSet the execution parameters and activate the Wake Up functionalityDisable the Wake Up functionality

The selection of the command displays the SNTP & Wake Up Config. contextual area

In order to deepen this topic, see:SNTP functionality (info)Wake Up functionality (info)

Verify the status of SNTP functionality

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > SNTP & Wake Up Config.The SNTP tab displays the activation status of SNTP functionality and the current setting of the relevantexecution parameters.

Set the execution parameters and activate the SNTP functionality

User Profile | Station Operator, System

WARNING The execution parameters (Main Server IP Address, Reserve Server IP Addr, etc.) can be mod-ified even when the SNTP functionality is already active.

1. Select Main > SNTP & Wake Up Config.

2. Set the IP address of the main element present in the network, from which the equipment automaticallygets the reference date/time, in the Main Server IP Address box.Typing a valid value (different from 0.0.0.0) involves the activation of the automatic acquisition of thereference date/time.

3. Set the IP address of the secondary element present in the network, from which the equipment auto-matically gets the reference date/time, in the Reserve Server IP Addr box.

4. Set the time interval between a request of refresh of the reference date/time and the next one in thePolling Interval (Sec.) box.Typing or selecting the arrows of the box, set a number between 1 and 16777215 seconds.

5. Set the time interval (t) the equipment must wait for, before re-attempting the transmission of a re-quest to the main or secondary element in the Polling Timeout (Sec.) box.Typing or selecting the arrows of the box, set a number between 1 and 30 seconds.

6. Set the number of times that the equipment must re-attempt the transmission of a request to the mainor secondary element in the Polling Retries box.Typing or selecting the arrows of the box, set a number between 1 and 10.

7. Press Apply and confirm.

Page 68: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

66 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Disable the SNTP functionality

User Profile | Station Operator, System

1. Select Main > SNTP & Wake Up Config.

2. Reset the value present in the Main Server IP Address box.The value can be reset deleting the IP address present in the box or setting the value 0.0.0.0.

3. Reset the value present in the Reverse Server IP Address box.The value can be reset deleting the IP address present in the box or setting the value 0.0.0.0.

4. Press Apply and confirm.

Verify the Wake Up functionality status

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > SNTP & Wake Up Config.

2. Select the Wake Up tab.The tab displays the sending status of the Wake Up trap and the current setting of the relevant sendingparameters.

Set the execution parameters and activate the Wake Up functionality

User Profile | Station Operator, System

WARNING The execution parameters (NMS IP Address, Timeout, etc.) cannot be modified when the WakeUp functionality is already active. First it is necessary Disable the Wake Up functionality and then the pa-rameters can be changed.

1. Select Main > SNTP & Wake Up Config.

2. Select the Wake Up tab.

3. Set the IP address of the server, which the Wake Up trap must be sent to, in the NMS IP Address box.

4. Set, in the Timeout (Minutes) box, the time interval for which the Wake Up trap is sent. When the time-out expires, the trap is automatically disabled.Typing or selecting the arrows of the box, set a number between 0 and 1440 minutes.The setting of the value 0 indicates that the trap is sent until when the user manually disables it or theNMS server automatically disables it when intercepts it.

5. Set the physical location (for example, the name of the site) of the equipment in the NE Location box.The setting of the parameter is optional.

6. Select the Enable option.

7. Press Apply and confirm.

Disable the Wake Up functionality

User Profile | Station Operator, System

1. Select Main > SNTP & Wake Up Config.

2. Select the Wake Up tab.

3. Select the Disable option or reset the value present in the NMS IP Address box (value 0.0.0.0).

4. Press Apply and confirm.

Page 69: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 67

SNTP & Wake Up Config. contextual area

In the contextual area is present the:SNTP tab. The tab displays the configuration parameters of the SNTP functionality.Wake Up tab. The tab displays the configuration parameters of the Wake Up functionality.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

SNTP tab

The tab displays the configuration parameters of the SNTP functionality.

Main Server IP Address / Reserve Server IP Addr. Activation status and IP address of the mainNE (Main) and of the secondary NE (Reserve) present in the network which the equipment automati-cally gets the reference date/time from. In detail, the automatic acquisition of the reference date/timeof the equipment is:

• Active, when a valid value (different from 0.0.0.0) is present in the Main Server IP Addressand/or Reverse Server IP Address box.

• Inactive, when the value 0.0.0.0 (IP address reset) is present in the boxes Main Server IPAddress and Reverse Server IP Address.

Polling Interval (Sec.). Time interval (expressed in seconds) between a request of reference date/time update and the next one.

Polling Timeout (Sec.). Time interval (expressed in seconds) that the equipment must wait beforere attempting the transmission of a request to the main or secondary element.

Polling Retries. Number of times that the equipment must re attempt the transmission of a requestto the main or secondary element.

NTP Server Lost Alarm. The activation of the NTP Server Lost Alarm indicates that none of the setnetwork elements is reachable, as consequence the reference date/time of the equipment is notaligned. The colour of the boxes represents the alarm status and severity:

• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-jor, Minor, Warning severity.

• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

Related TopicsSet the execution parameters and activate the SNTP functionalityDisable the SNTP functionality

SNTP functionality (info)

Wake Up tab

The tab displays the configuration parameters of the Wake Up functionality.

Status. Transmission status of Wake Up trap. The sending of the Wake Up trap is:• Active, when the Enable option is selected and a valid value (different from 0.0.0.0) is set

as IP address of the server (option NMS IP Address).• Inactive, when the Disable option is selected and the value 0.0.0.0 is set as IP address of

the server (option NMS IP Address).

Page 70: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

68 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

NMS IP Address. IP address of the server which the Wake Up trap must be sent to. With server wemean the machine where the supervision system NMS5UX, NMS5UX-B or NMS5LX or a different man-agement system, able to manage the reception of the Wake Up trap, is installed.

Gosip Address. Not available in this context.

Timeout (Minutes). Time interval for which the Wake Up trap, when enabled, is sent to the server.The setting of the value 0 indicates that the trap is sent until when the user manually disables it or theNMS server automatically disables it when intercepts it.

NE Location. Optional parameter. The user can insert the physical location (for example the name ofthe site) of the equipment in this field. This information is communicated to the remote manager to-gether with the characteristics of the equipment. The supervision system NMS5UX, NMS5UX-B orNMS5LX does not use this information.

Related TopicsSet the execution parameters and activate the Wake Up functionalityDisable the Wake Up functionality

Wake Up functionality (info)

Page 71: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 69

SNTP functionality (info)

ALFOplus80 equipment, via SNTP (Simple Network Time Protocol) protocol, can update its date/time usingan element within the network as reference (SNTP functionality).

Via WEB LCT (or SCT/LMT) application, a maximum of two elements can be defined, one main (set in theMain Server IP Address box) and one secondary (set in the Reserve Server IP Addr box), from which theequipment automatically gets the reference date/time each n seconds (set in the Polling Interval box). En-tering a valid value for the main and/or secondary element activates the functionality.

If the main element does not answer to the request of updating of the equipment reference date/time, thisrequest is sent for n times (set in the Polling Retries box) each t seconds (set in the Polling Timeout box).At the end of this requests, if the main element does not answer, the equipment requires the updating ofthe date/time to the secondary element.

If the secondary element does not answer to the request of updating of the equipment reference date/time, this request is sent for n times each t seconds. At the end of this request, if the secondary elementdoes not answer the equipment, the system activates the SNTP servers lost Alarm and requires the updateof the date/time of the main element and so on.

If no network element set can be reached, the reference date/time of the equipment is not updated. Thiscondition is signalled by the activation of NTP Server Lost Alarm (SNTP tab).

To deactivate the automatic acquisition of the reference date/time, the IP address of the main and second-ary elements must be reset.

Wake Up functionality (info)

The Wake Up functionality allows the user enabling the spontaneous forward, from the equipment to a re-mote server, of a SNMP trap for the notification of the equipment commissioning (Wake Up trap).

This functionality has been implemented as help to the Auto Discovery modality available in the supervisionsystems NMS5UX, NMS5UX-B and NMS5LX.

The Auto Discovery mode has the purpose to point out new equipment in the network, not managed bythe supervision system yet. More information about the Auto Discovery modality is reported in the relevantdocumentation.

This chapter shows only the management of the Wake Up trap by the equipment. In detail, the implemen-tation of the Wake Up functionality is the following.

Via WEB LCT (or SCT/LMT) application, it is possible:• Define the IP address of the server where the supervision system, which the trap must be sent

to (NMS IP Address option - Wake Up tab) is installed.• Define the time interval for which the trap must be sent, after which the sending of the trap is

automatically disabled (Timeout option).If the value 0 is set for the Timeout option, the Wake Up trap will be sent until when the usermanually disables it or the NMS server automatically disables it when intercepts it.

• Activate and deactivate the sending of the trap.To activate the Wake Up functionality, it is necessary to set a valid value (different from 0.0.0.0)for the IP address of the server (NMS IP Address option) and select the Enable option.To deactivate the functionality, it is necessary to select the Disable option or reset the NMS IPAddress option (value 0.0.0.0).

When the Wake Up functionality is activated, the equipment starts sending the Wake Up trap every minutefor the time interval defined by the user (Timeout option). For example, if the value 60 has been set astimeout, the trap is sent each 60 minutes. At the end of 60 minutes, the sending of the trap is automaticallydisabled.

If, in the period when the sending of the trap is enabled, the supervision system intercepts the Wake Upnotification records the presence of the new equipment in its database and disables the sending of theWake Up trap by the equipment (trap switch-off).

Page 72: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

70 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Software Info & Maint.

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Software Info & Maint. command manages the equipment firmware, the WEB LCT software presentin the equipment, the communication stack used by the equipment and the restore of the default equip-ment settings.In detail, the command allows:

EQUIPMENT FIRMWARE

Verify the firmware version of the equipmentUpdate the firmware of the equipmentSwitch the operation of the memory benches relevant to the main controller

WEB LCTVerify the WEB LCT version present into the equipmentUpdate the WEB LCT application

COMMUNICATION STACK/FACTORY DEFAULT

Verify the communication stack in useRestore Factory Default of the equipment

SOFTWARE RESET

Execute the equipment software reset

The selection of the command displays the Software Info & Maint contextual area

In order to deepen this topic, see:Equipment firmware (info)Factory Default of the equipment (info)Rescue connection (info)

Verify the firmware version of the equipment

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Software Info & Maint.The Equipment Firmware tab shows version, status and composition of the equipment firmware.

Update the firmware of the equipment

User Profile | Station Operator, System

WARNING The application automatically updates the firmware of the memory bench not on progress or notpresent (Bench Status parameter - Loaded or Not Loaded value). This operation cannot be executed when the firmware update is already in progress (Download Status pa-rameter - Downloading value). The firmware update procedure could change the equipment functions.

1. If not already active, run the WEB LCT Console program or the SCT/LMT program, necessary to managethe operation of FTP for the file transfer.

2. Select Main > Software Info & Maint.

3. Press Upgrade.

Page 73: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 71

4. In the box Download file path, type the path and the name of the file you wish to use for update.The file you wish to use for the operation must be on the local PC (PC where the browser used for thedisplay of WEB LCT is running).

5. Set the download type to be executed, selecting the option:• Forced, if you are updating the firmware of main controller of the equipment.• Only difference or not present / peripheral, if you are updating the firmware of peripheral units

(FPGA file and/or application code).

6. Activate the Bench Switch? box, if at the end of the download, the system has automatically to executea switching of the memory bench, in such a way to use the bench with the firmware that has beenupdated.

7. Press Start and confirm.Before executing the updating, the system executes a compatibility check between the file to be for-warded to the equipment and the one present on the terminal.The check consists of comparing the technology type of the equipment.If the parameters are incompatible, the application does not executes the firmware update: the wordingInterrupted is displayed in the Download Status box of the branch whose firmware you are updating.If the parameters are compatible, the operation is started and the Download Status box of the branchwhose firmware you are updating dynamically updates the progress of the operation, which requiressome minutes:

• Downloading. The operation is running.The Abort push-button, present in the Download Status box during the firmware update, canbe used to stop the operation. Its selection requires the confirmation.During the updating, the system deletes the firmware present into the bench memory and it up-dates the firmware of the equipment one component at a time.If the operation is stopped, into the memory bench there will be only the already updated com-ponents. In this case, the new version can result unusable because not integral (the bench willbe in Not Loaded status).In this case, the controller keeps the minimum functions necessary to allow a new firmware up-date.

• Complete. The update operation is ended.The Software Version box indicates the new firmware version.

Switch the operation of the memory benches relevant to the main controller

User Profile | Station Operator, System

WARNING Memory benches cannot be switched during the firmware update (Download Status parameter- Downloading value) and when the firmware of the equipment is not present on a bench (Bench Statusparameter - Not Loaded value).Usually, the switch of the memory benches of main controller does NOT interrupt the traffic. This operationcan temporarily interrupt the traffic if the new loaded version contains a new FPGA version.

1. Select Main > Software Info & Maint.

2. Press Bench Switch and confirm.The equipment is restarted; on the reconnection, the bench in Running status is forced to Loaded statusand vice versa.

Verify the WEB LCT version present into the equipment

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Software Info & Maint.

2. Select the WEB LCT tab tab.The tab displays the characteristics of WEB LCT application present in the equipment.

Page 74: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

72 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Update the WEB LCT application

User Profile | Station Operator, System

1. Select Main > Software Info & Maint.

2. Select the Web LCT tab.

3. Press Browse.

4. Select the file (with tar extension) you wish to use for the update.The File name box displays the selected file.

5. Press Upload and the confirm.Before starting the update, the compatibility between the WEB LCT which must be sent to the equip-ment and the one present in the terminal is checked.The check consists in comparing the type of equipment.If the parameters are not compatible, the application does not execute the update of WEB LCT (thesystem displays the message Upload aborted. Probable cause wrong...).If the parameters are compatible, the operation is started. The update requires some minutes.At the end of the operation, to avoid the misalignment between the displayed data and the new appli-cation, the WEB LCT page is closed and the page Login is displayed.

Verify the communication stack in use

User Profile | System

1. Select Main > Software Info & Maint.

2. Select the IP/OSI stack switch tab.The tab displays the communication stack in use.

Restore Factory Default of the equipment

User Profile | System

WARNING The operation, if executed on an equipment subjected to the radio supervision, could cause theloss of the link because the restore of the factory settings involves the re-channelling of the radios to thedefault values.

1. Select Main > Software Info & Maint.

2. Select the IP/OSI stack switch tab.

3. Activate the Factory Default check-box.

4. Press Apply.

5. Into the Please insert system password box, type the access code of System user and press OK.At the end of the operation, the message The new settings will be active after a software restart is dis-played.

6. Press OK to close the window.

7. Press Restart and confirm.The default configuration will be automatically applied at the equipment restart (see Factory Default ofthe equipment (info).

Page 75: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 73

Execute the equipment software reset

User Profile | System

WARNING After the reset, all the values activated before the operation result as valid ones.

1. Select Main > Software Info & Maint.

2. Select the IP/OSI stack switch tab.

3. Press Restart and confirm.

Page 76: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

74 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Software Info & Maint contextual area

In the contextual area is present the:Equipment Firmware tab. The tab displays the version and the status of the equipment firmware.WEB LCT tab. The tab displays the characteristics of the WEB LCT application present in the equipment.IP/OSI stack switch tab. The tab displays the communication stack in use.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on-line.

Equipment Firmware tab

The tab shows the version, the status and the composition of the equipment firmware.The tab contains two tables.

The first table displays the version and the status of the equipment firmware.

Software Version. File name and version of the equipment firmware respectively present on thememory bench 1 (Bench 1 column) and 2 (Bench 2 column).

Bench Status. Operating status of memory benches 1 (Bench 1 column) and 2 (Bench 2 column):• Running. The firmware is running on the relevant memory bench.• Loaded. The firmware is present on the bench, but it is not currently running (standby).• Not Loaded. The firmware is not present in the memory bench.

Download Status. Status of the update operation of the firmware respectively present on memorybench 1 (Bench 1 column) and 2 (Bench 2 column):

• ---. Firmware update is not in progress.• Downloading. The update of the firmware relevant to the memory bench is in progress.• Interrupted. The update of the firmware has been interrupted.• Complete. The update operation is ended.

The second table displays the list of the codes and of the FPGA files composing the equipment firmware.Every row corresponds to a firmware element (code or FPGA) for which is pointed out in the column:

Unit. Name of the unit or of the equipment part where there is the controller (code) or the program-mable device (FPGA file).

Software. Firmware name. Usually the name indicates the component type:• FW_boot. Boot code. This part of code cannot be updated. In fact, it is not provided with a

version of the memory benches.• FW_appl. Application code.• Conf_... or FPGA... Configuration file of the programmable devices.

Actual Release. Version of the code or of the FPGA file present into the controller.For some elements, the system indicates the version and also the relevant identification code composedby the letter E or N followed by a number (each number identifies a different code type).

Release Bench 1. Firmware version present into the memory bench 1 of the controller.

Release Bench 2. Firmware version present into the memory bench 2 of the controller.

Push-button:Upgrade. Update the firmware of the equipment.Bench Switch. Switch the operation of the memory benches relevant to the main controller.

Page 77: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 75

Related TopicsEquipment firmware (info)

WEB LCT tab

The tab displays the characteristics of WEB LCT application present in the equipment.

Description. Application type present into the equipment (WEB LCT).

Code. Identification code of WEB LCT application present into the equipment.

Current version. WEB LCT version present into the equipment.

Push-button:Browse. Open the window of O.S. for the selection of the file you wish to use for the update.Upload. Update the WEB LCT application.

IP/OSI stack switch tab

WARNING Tab available only to System.

The tab displays the communication stack in use.

Current Stack. Communication stack in use:• IP. Communication stack Full IP. • OSI. Communication stack IP Over OSI (not available).

Push-button:Apply. Restore Factory Default of the equipment.Restart. Execute the equipment software reset.

Related TopicsFactory Default of the equipment (info)Rescue connection (info)

Page 78: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

76 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Equipment firmware (info)

The firmware of the equipment is the assembly of all the firmware necessary for the management of theentire equipment (firmware of the main controller and firmware of the peripheral units).

The firmware of the equipment is present into the main controller that is provided with two memory bench-es (bench) the first one on service and the other one in waiting status.

Each bench can contain one firmware version (also different from the other one) of the equipment.

It is possible to update the equipment sw/fw relevant to one memory bench only at a time. The applicationautomatically updates the firmware of the memory bench not running or not present (Bench Status pa-rameter - Loaded or Not Loaded value).

Factory Default of the equipment (info)

Through the graphical interface WEB LCT, the Factory Default settings of an equipment can be restored.

At the restart or at the new switch-on of the equipment, the Factory Default configuration will be applied.

All the settings executed until then by the user will be deleted (for example, user list, remote equipmentlist, etc.).

In Factory Default status, the connection to the equipment and to the link takes place by means of theEthernet port AUX and using the connection modality Out of Band.

In order to login to the equipment, the default user must be used. Username: SYSTEM - Password: siae-micr.

The communication ports of the equipment will be restored to the addresses pointed out in Tab.2.

These addresses differ depending on the type (High or Low) of ODU. The equipment keeps always in mem-ory the type (High or Low) of the last connected ODU.

Tab.2 Factory Default - ALFOplus80

IF THE EQUIPMENT IS INSERTED INTO AN IP NETWORK

Rescue connection (info)

If the user has lost the connection with the equipment because of a wrong configuration of the connectionparameters, the recovery procedure can be used (rescue connection).

At switch-on, the equipment opens a time window of 20 seconds during which it makes itself reachable onthe LAN 1 and LAN 2 using the rescue connection address and accepts the user login through the correctusername and password. In this modality, the LAN 1 and LAN 2 accepts only frames without VLAN tag.

The rescue connection IP address is: 172.20.253.13.

Once logged in, the user can configure the equipment and possible, restore the Factory Default condition.

The detection of the time window during which the rescue connection can be attempted is managed by anexternal software application.

Parameter IP Address NetMask ODU

Ethernet port 172.20.254.14 255.255.0.0 Low

172.20.255.15 255.255.0.0 High

Default Gateway null - Low

null - High

Agent IP Address Local Ethernet address

Page 79: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 77

Backup/Restore Config.

User Profile | Station Operator, System

The Backup/Restore Config. command manages the backup/restore from file of the whole equipmentconfiguration.In detail, the command allows:

Save the whole equipment configuration (backup configuration)Transfer the equipment configuration previously saved (restore configuration)Retrieve the equipment configuration automatically saved by the program before the last operation ofconfiguration restore (revert configuration)

The selection of the command displays the Backup/Restore Config. contextual area

In order to deepen this topic, see Backup/restore of the equipment configuration (info)

Save the whole equipment configuration (backup configuration)

User Profile | Station Operator, System

1. If not already active, start the WEB LCT Console or SCT/LMT program, necessary to manage the oper-ation of FTP for the file transfer.

2. Select Main > Backup/Restore Config.

3. Type, in the Backup file name box, the path where you wish to save the file and the name of the filewith bak extension.It is possible to set a name already existing for the file in the chosen path. In this case, the data presentin the file will be overwritten.

4. Press Backup and confirm.A window shows the progress of the operation. To stop the operation, press Abort and confirm.A message displays the result of the operation.

Transfer the equipment configuration previously saved (restore configuration)

User Profile | Station Operator, System

1. If not already active, start the WEB LCT Console or SCT/LMT program, necessary to manage the oper-ation of FTP for the file transfer.

2. Select Main > Backup/Restore Config.

3. Set, in the Restore file name box, the name of the file you wish to use to restore the configuration.

4. Press Restore and confirm.A window shows the progress of the operation. To stop the operation, press Abort and confirm.A message displays the result of the operation.

Page 80: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

78 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Retrieve the equipment configuration automatically saved by the program before the last operation of configuration restore (revert configuration)

User Profile | Station Operator, System

1. If not already active, start the WEB LCT Console or SCT/LMT program, necessary to manage the oper-ation of FTP for the file transfer.

2. Select Main > Backup/Restore Config.The Reverte parameter indicates the date/time of the backup file automatically created by the programbefore the last restore operation.The format of date/time changes according to the setting made in one’s operating system.The wording --- indicates that the file is not available.

3. Press Revert and confirm.A window shows the progress of the operation. To stop the operation, press Abort and confirm.A message displays the result of the operation.

Page 81: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 79

Backup/Restore Config. contextual area

The contextual area contains the items to manage the backup/restore of the file of the whole equipmentconfiguration.

Backup file name. Type, in this box, the path and the name of the file which you wish to save thewhole equipment configuration to.

Restore file name. Type, in this box, the path and the name of the file which you wish to use for therestore of the previously saved configuration.

Reverte. This parameter indicates the date/time of the backup file automatically created by the pro-gram before the last restore operation. The format of date/time changes according to the setting madein one’s operating system. The wording --- indicates that the file is not available.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on-line.

Backup. Save the whole equipment configuration (backup configuration).Restore. Transfer the equipment configuration previously saved (restore configuration).Reverte. Retrieve the equipment configuration automatically saved by the program before the last op-eration of configuration restore (revert configuration).

Related TopicsBackup/restore of the equipment configuration (info)

Page 82: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

80 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Backup/restore of the equipment configuration (info)

The WEB LCT program allows Save the whole equipment configuration (backup configuration). The savedfile is in binary format and can be saved on PC or external support according to the user needs.

Then, in any moment, the user can restore the equipment configuration saved to file transferring the dataof the file to the same equipment (configuration restore - Transfer the equipment configuration previouslysaved (restore configuration)).

Before restoring the configuration, the equipment saves its own current configuration and keeps it availableuntil the successive restore operation.

In any moment, the user can Retrieve the equipment configuration automatically saved by the programbefore the last operation of configuration restore (revert configuration).

In this way, two backup versions will be always available for an equipment: one executed by the user andthe other automatically executed by the program before the last restore operation.

Page 83: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 81

Alarm Severity Config.

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Alarm Severity Config. command manages the alarm transmission and their severity level.In detail, the command allows:

Verify the severity level and the enabling/forwarding status of the alarmsEnable/disable an alarmEnable/disable the forwarding of the trap of an alarmChange the severity level of an alarm

The selection of the command displays the Alarm Severity Config. contextual area

In order to deepen this topic, see Alarms (info)

Verify the severity level and the enabling/forwarding status of the alarms

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Main > Alarm Severity Config.The Alarm Severity Config. contextual area displays the alarms configuration.

Enable/disable an alarm

User Profile | Station Operator, System

1. Select Main > Alarm Severity Config.

2. Select the alarm and press Edit Alarm Config or double click on the alarm.

3. Set the Severity parameter, selecting:• Disable, to disable the alarm.• Status, Warning, Minor, Major or Critical to enable the alarm. Select the option relevant to the

severity level to be assigned to the alarm

4. Press Ok.The settings are reported in the Alarm Severity Config. contextual area. The symbol [*] is displayednext to the name of the changed alarm.

5. Press Apply and confirm.

Enable/disable the forwarding of the trap of an alarm

User Profile | Station Operator, System

WARNING The forwarding status of the trap can be changed only if the alarm is enabled (see Enable/disablean alarm).

1. Select Main > Alarm Severity Config.

2. Select the alarm and press Edit Alarm Config or double click on the alarm.

3. Set the Trap parameter, selecting:• Enable, to enable the forwarding of the alarm trap to the management system.

Page 84: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

82 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Disable, to disable the forwarding of the alarm trap to a possible management system externalto the equipment (for example SCT/LMT and/or NMS5UX/NMS5UX-B/NMS5LX).

4. Press Ok.The settings are reported in the Alarm Severity Config. contextual area. The symbol [*] is displayednext to the name of the changed alarm.

5. Press Apply and confirm.

Change the severity level of an alarm

User Profile | Station Operator, System

1. Select Main > Alarm Severity Config.

2. Select the alarm and press Edit Alarm Config or double click on the alarm.

3. Set the Severity parameter, selecting the severity you wish to associate to the alarm: Status, Warning,Minor, Major or Critical.If the alarm was disabled (Disable option selected), the selection of a different option, besides modify-ing the alarm severity level, automatically enables it.

4. Press Ok.The settings are reported in the Alarm Severity Config. contextual area. The symbol [*] is displayednext to the name of the changed alarm.

5. Press Apply and confirm.

Page 85: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 83

Alarm Severity Config. contextual area

The contextual area displays the alarms configuration.

Alarms are subdivided into groups.When contextual area is opened, only the groups are displayed (Group/Alarm column).To expand and compress the list of alarms associated to a group, select the symbol next to the nameof the group. Every selection of the symbol makes the list assumes the status complementary to the pre-vious one (if compress it becomes expanded and vice versa). The groups and the alarms change according to the equipment configuration.

When a group is expanded, for every alarm is pointed out in the column:

Group/Alarm. Alarm name.A coloured box is before the name, pointing out the alarm status and severity:

• White box with red X. Alarm disabled.• Green box. Alarm enabled with severity equivalent to a status signal.• Light blue box. Alarm enabled with Warning severity.• Yellow box. Alarm enabled with Minor severity.• Orange box. Alarm enabled with Major severity.• Red box. Alarm enabled with Critical severity.

The presence of an asterisk [*] between the box and the alarm name indicates that at least one char-acteristic of the alarm has been changed.

Severity. Enabling status of the alarm and, if enabled, relevant severity level:• Disabled. Alarm disabled.• Status. Alarm enabled with severity equivalent to a status signal.• Warning, Minor, Major or Critical. Alarm enabled with severity respectively Status, Warning,

Minor, Major or Critical.• Not available in this SW version. Alarm not supported by the current firmware version pre-

sent into the equipment controller.

Trap Notification. Forwarding status of the trap:• Enabled. The transmission of the alarm trap to the management system is enabled.• Disabled. The transmission of the alarm trap to a possible external management system is

disabled (for example SCT/LMT and/or NMS5UX/NMS5UX-B/NMS5LX).• ---. Information not meaningful because the alarm is disabled.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Edit Alarm Config. Enable/disable an alarm, Enable/disable the forwarding of the trap of an alarm orChange the severity level of an alarm

Related TopicsAlarms (info)

Page 86: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

84 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Alarms (info)

Alarm and status signalsEnabling/disabling the alarmsEnabling/disabling the forwarding of the alarm trapsAlarm severity

Alarm and status signals

The term alarm defines the fault signal generated by an error or malfunction of the equipment or of anycomponent that composes it.The term status identifies instead the signals referring to any event that does not indicates a malfunctionbut a status change, an operation in progress or an operating indication.The term event defines each single signal of status, detected alarm and cleared alarm.A maximum of 400 events are recorded in the equipment controller. When this limit is exceeded, each newevent will overwrite the oldest event.

Enabling/disabling the alarms

The equipment alarms can be disabled and re-enabled by the user according to the needs.Disabling an alarm means that, on the detection of the alarm itself, this is not registered in the equipmentcontroller and, as consequence, is not communicated to a possible management program: as the alarmhad never occurred.On the contrary, enabling an alarm (default condition) means that, when the alarm is detected, this is reg-istered in the equipment controller and, if the forwarding of the relevant trap is enabled (see next item),the alarm is communicated to the management system and displayed in the current alarms and the historyalarms.

WARNING The enabling/disabling of the alarm is independent for each alarm and local to the equipmentwhich the operation is executed for. This means that the setting must be executed for each single alarmof each single equipment.

Enabling/disabling the forwarding of the alarm traps

The trap is a message (in this case of detection or clearing of an alarm) spontaneously sent by the equip-ment to a possible external management system, for example SCT/LMT and/or NMS5UX/NMS5UX-B/NMS5LX.The forwarding of the trap of each alarm can be disabled and re-enabled by the user according to his ownneeds.Disabling a trap means that, on the detection of the alarm, this is not registered in the equipment controllerand, as consequence, is not communicated to a possible management program.On the contrary, enabling a trap (default condition) means that, on the detection of the alarm, this is reg-istered in the equipment controller and communicated to the management system, which displays it in thecurrent alarms and the history alarms.

WARNING The enabling/disabling of the forwarding of the trap is independent for each alarm and local tothe equipment which the operation is executed for. This means that the setting must be executed for eachsingle alarm of each single equipment.

Alarm severity

Each alarm acknowledged and managed by the management program has an associated severity levelwhich determinates the importance of the alarm.This severity is not fixed, but can be changed by the user as he likes.

Page 87: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 85

User Manager

User Profile | System

The User Manager command manages the list of the equipment users.In detail, the command allows:

Verify the user listAdd a user to the listModify a user into the listDelete a user from the listChange the password and the timeout of the System userChange the network password and timeoutChange the password and the timeout of NMS5UX userVerify/modify the IP address of Permanent Login

The selection of the command displays the User Manager contextual area

In order to deepen this topic, see User list (info)

Verify the user list

User Profile | System

1. Select Main > User Manager.The User Manager contextual area displays the user list currently stored in the equipment is displayed.

Add a user to the list

User Profile | System

WARNING For every list, a maximum of 4 users can be defined for every profile (totally up to 12 users).

1. Select Main > User Manager.

2. Select Add.

3. In the User box, type the user name (alphanumeric string with a number of characters from 1 up to 8).The same name cannot be assigned to two different users present in the same list. Then, when the username has been assigned, it cannot be changed later.

4. Into the Password box, type the access code of the (alphanumeric string with a number of charactersfrom 1 up to 8).

5. Into the Confirm Password box, type newly the access code of the user.

6. Into the User Profile box, set the profile to be assigned to the user:• Read Only. The user with this profile can check the parameters but it can not forward commands

or execute changing to the equipment configuration.• Read & Write. The user with this profile can check the parameters and execute only maintenance

operations (MAN OP).• Station Op. The user with this profile can as check the parameters as send commands or execute

changes to the equipment configuration except for the following operations: modifying the userlist, aligning the date/time of the equipment, force the logout of an user and all those operationsavailable only to the System user (or NMS5UX).

It is not possible to create a user with System profile.

7. Set the timeout of the WEB LCT session opened by the user. In detail, if you wish:

Page 88: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

86 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• The session of WEB LCT opened by the user (even if disconnected) is kept for an undefined pe-riod (session timeout disabled), deactivate the box Login Timeout.

• The session of WEB LCT opened by the user, if disconnected, is automatically terminated oncereached a specific time limit (session timeout disabled), activate the box Login Timeout and typea value between 1 and 43200 sec. (12h) in the box User Keep Alive (Sec.).With disconnected session we mean a WEB LCT session whose relevant WEB LCT has beenclosed but for which the disconnection from the equipment has not been executed (user logout).

8. Press Apply and confirm.The new user is inserted in the list and communicated to the equipment.

Modify a user into the list

User Profile | System

1. Select Main > User Manager.

2. Select the user and press Modify or double click on the user.

3. Execute the changing.The setting modes of the parameters are the same ones above pointed out into the par. Add a user tothe list.Each time even a single parameter is changed, the access code (parameter Password, Confirm pass-word) must be inserted. The user name (parameter User) cannot be modified.

4. Press Apply and confirm.

Delete a user from the list

User Profile | System

1. Select Main > User Manager.

2. Select the user.

3. Press Remove and confirm.

Change the password and the timeout of the System user

User Profile | System

WARNING If you wish to change only the timeout, it is necessary to input the current password of the Sys-tem user in the Password and Confirm Password fields.

1. Select Main > User Manager.

2. Press System.

3. To change the password:

a. Into the Password box, type the new access code of System user (alphanumeric string with anumber of characters from 1 up to 8).

b. Into the Confirm Password box, type newly the access code.

4. To change the timeout of the WEB LCT session opened by System user:• Disable the Login Timeout box. The WEB LCT session opened by the System user (even if dis-

connected) will be kept for an indefinite period of time (session timeout disabled).• Enable the Login Timeout box. The WEB LCT session opened by the System user, if disconnect-

ed, will be automatically ended once reached the set time limit (Session timeout enabled).

Page 89: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 87

To set time limit type, in the User Keep Alive (Sec.) box, a value between 1 and 43200 sec.(12h).

With disconnected session we mean a WEB LCT session whose relevant WEB LCT has been closed butfor which the disconnection from the equipment has not been executed (user logout).

5. Press Apply and confirm.

Change the network password and timeout

User Profile | System

WARNING If you wish to change only the timeout, it is necessary to input the current network password inthe Password and Confirm Password fields.

1. Select Main > User Manager.

2. Press Network.

3. To change the password:

a. Into the Password box, type the new network password (alphanumeric string with a number ofcharacters from 1 up to 8).

b. Into the Confirm Password box, type newly the new network password.

4. To change the timeout of the WEB LCT session of the remote equipment:• Disable the Login Timeout box. The WEB LCT session of the remote equipment (even if discon-

nected) will be kept for an indefinite period of time (session timeout disabled).• Enable the Login Timeout box. The WEB LCT session of the remote equipment, if disconnected,

will be automatically ended once reached the set time limit (Session timeout enabled).To set time limit type, in the User Keep Alive (Sec.) box, a value between 1 and 43200 sec.(12h).

With disconnected session we mean a WEB LCT session whose relevant WEB LCT has been closed butfor which the disconnection from the equipment has not been executed (user logout).

5. Press Apply and confirm.

Change the password and the timeout of NMS5UX user

User Profile | System

WARNING The change of NMS5UX user (CEM password) has to be executed only if the default passwordused by the NMS5UX/NMS5UX-B/NMS5LX supervisory system is changed. If you wish to change only the timeout, it is necessary to type the current NMS5UX user password into thePassword and Confirm Password fields.

1. Select Main > User Manager.

2. Press CEM.

3. To change the password:

a. Into the Password box, type the new NMS5UX user password (alphanumeric string with a num-ber of characters from 1 up to 8).

b. Into the Confirm Password box, type newly the access code.

4. To change the timeout of the WEB LCT session opened by NMS5UX user:• Disable the Login Timeout box. The WEB LCT session opened by the NMS5UX user (even if dis-

connected) will be kept for an indefinite period of time (session timeout disabled).• Enable the Login Timeout box. The WEB LCT session opened by the NMS5UX user, if disconnect-

ed, will be automatically ended once reached the set time limit (Session timeout enabled).To set time limit type, in the User Keep Alive (Sec.) box, a value between 1 and 43200 sec.(12h).

Page 90: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

88 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

With disconnected session we mean a WEB LCT session whose relevant WEB LCT has been closed butfor which the disconnection from the equipment has not been executed (user logout).

5. Press Apply and confirm.

Verify/modify the IP address of Permanent Login

User Profile | System

WARNING The remote user has the same characteristics of the NMS5UX user with the only exception thathe does not need for a login password. A maximum of 2 remote users can be set.

1. Select Main > User Manager.

2. Press Permanent Login.The box:

• Manager IP Address 1 indicates the IP address of the machine relevant the first remote user.• Manager IP Address 2 indicates the IP address of the machine relevant the second remote user.

Value 0.0.0.0 indicates the parameter is disabled.The setting of the box Trap Version 2 present below every box indicates the version (SNMP) used forthe trap sending. In detail, if the box is:

• Active. For the specific remote user, the sending of trap in version 2 is enabled.• Inactive. For the specific remote user, the sending of trap in version 1 is enabled.

3. To change the IP address of the machine relevant the first remote user, type a valid IP address in theManager IP Address 1 box.

4. To change the IP address of the machine relevant the second remote user, type a valid IP address inthe Manager IP Address 2 box.

5. Activate the Trap Version 2 option, under the relevant Manager IP Address… box, to set the trap man-agement of version 2 (SNMP).If the option is not activated, the version 1 (SNMP) of the traps is used.

6. Press Apply and confirm.

Page 91: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 89

User Manager contextual area

The table, present in the contextual area, displays the user list currently stored in the equipment is dis-played.Every row of the table corresponds to one user. For every user, is pointed out in the column:

User name. User name.

Profile. User profile:• Read Only. The user with this profile can check the parameters but it can not forward com-

mands or execute changing to the equipment configuration.• Read & Write. The user with this profile can check the parameters and execute only mainte-

nance operations (MAN OP).• Station Op. The user with this profile can as check the parameters as send commands or

execute changes to the equipment configuration except for the following operations: modi-fying the user list, aligning the date/time of the equipment, force the logout of an user andall those operations available only to the System user (or NMS5UX).

User Keep Alive. Timeout of WEB LCT session opened by the user:• No Timeout. Session timeout disabled. WEB LCT session opened by the user (even if discon-

nected) will be kept for an indefinite period of time.• <number> Seconds. Session timeout enabled. WEB LCT session opened by the user, if dis-

connected, will be automatically ended once reached the set time limit.With disconnected session we mean a WEB LCT session whose relevant WEB LCT page has been closedbut for which the disconnection from the equipment has not been executed (user logout).

The System and NMS5UX users are not pointed out into the list.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on-line.

Add. Add a user to the list.Modify. Modify a user into the list.Remove. Delete a user from the list

System. Change the password and the timeout of the System user.Network. Change the network password and timeout.CEM. Change the password and the timeout of NMS5UX user

Permanent Login. Verify/modify the IP address of Permanent Login

Related TopicsUser list (info)

Page 92: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

90 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

User list (info)

The users list is a list of users that can be connected and ask for the login to the equipment.If a user is not present in the users list memorized in the equipment controller, this user will not be ableto connect and/or to execute the login to that equipment.Each equipment, that can be managed by the WEB LCT or SCT/LMT application, is equipped with two presetusers:

SYSTEM. User of the WEB LCT application or SCT/LMT program with the following features:User name: System (unchangeable parameter).Timeout: No Timeout (changeable parameter).Profile: System (unchangeable parameter).Password: Siaemicr (default) (changeable parameter - see Change the password and thetimeout of the System user).

The System user is single one for every equipment and he can not be deleted.The user with System profile can create, modify and delete users in the user list; check the param-eters (reading operation), send commands or modify the equipment configuration (writing opera-tion). NMS5UX. User of the NMS5UX/NMS5UX-B/NMS5LX system, with the following features:

User name: NMS5UX (unchangeable parameter).Timeout: No Timeout (changeable parameter).Profile: System (unchangeable parameter).Password: Pre-define (changeable parameter - see Change the password and the timeout ofNMS5UX user).

The NMS5UX user can not be deleted.More information about the NMS5UX/NMS5UX-B/NMS5LX system is reported in the relevant docu-mentation.

In every user list, up to 12 different users can be created besides the predefined users (see Add a user tothe list); the user configuration can be modified (see Modify a user into the list) and deleted (see Delete auser from the list).All the users of the users list relevant to an equipment (with the exception of the System and NMS5UX),have to be set by the WEB LCT application, the SCT/LMT program or NMS5UX/NMS5UX-B/NMS5LX system.

Page 93: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 91

EQUIPMENT

BW & Mod./Link ID. It manages the parameters relevant to modulation/capacity and link identificationnumber.General Preset. It manages the modem and radio parameters.

Page 94: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

92 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

BW & Mod./Link ID

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The BW & Mod./Link ID command manages the parameters relevant to modulation/capacity and the linkidentification number.In detail, the command allows:

Verify/modify the reference band/modulationVerify/modify the link identification number

The selection of the command displays the BW & Mod./Link ID contextual area.

Verify/modify the reference band/modulation

User Profile | Station Operator, System

1. Select Equipment > BW & Mod./Link ID.The Bandwidth & Modulation parameter indicates the equipment operating band/modulation:

• 750 MHz - 4QAM• 1 GHz - 4QAM

2. To change the parameter, select the wished value in the box.

3. Press Apply and confirm.

Verify/modify the link identification number

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Equipment > BW & Mod./Link ID.The Local Link ID parameter indicates the link identification number.

2. To change the parameter, type the new value in the box (value between 1 and 255).Setting the value 0 corresponds to not selecting the identification number.

3. Press Apply and confirm.The setting so executed does NOT automatically modify also the identification number of the remoteequipment.

Page 95: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 93

BW & Mod./Link ID contextual area

The BW & Mod./Link ID contextual area displays the parameters:

Local Link ID. Link identification number.

Bandwidth & Modulation. Channelling and modulation of the radio.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Related TopicsVerify/modify the reference band/modulationVerify/modify the link identification number

Page 96: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

94 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

General Preset

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The General Preset command manages the modem and radio parameters.In detail, the command allows:

Verify/modify the threshold level of the signal at receptionVerify/modify the radio branch labelVerify/modify the generation of the antenna aiming signal

The selection of the command displays the General Preset contextual area

Verify/modify the threshold level of the signal at reception

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Equipment > General Preset.The Rx Signal Level Alarm Threshold: <current value> dBm parameter indicates the threshold level ofthe signal at reception. Under this threshold level, the relevant alarm is activated.

2. To change the parameter, move the cursor to the wished level.

3. Press Apply and confirm.

Verify/modify the radio branch label

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Equipment > General Preset.The Radio Branch Label parameter indicates the label that identifies the radio branch.

2. To change the parameter, type the new label (alphanumeric string with maximum 30 characters).

3. Press Apply and confirm.

Verify/modify the generation of the antenna aiming signal

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Equipment > General Preset.The RSSI (Received Signal Strength Indication) parameter indicates the enabling state of the genera-tion of the antenna aiming.

• Enable. The function is enabled.• Disable. The function is disabled.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

4. Execute the equipment software reset.

Page 97: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 95

General Preset contextual area

The General Preset contextual area shows the modem and radio parameters.

Rx Signal Level Alarm Threshold: <current value> dBm. Threshold of the signal at reception.

Radio Branch Label. Label that identifies the radio branch.

RSSI. Enabling state of the generation of the antenna aiming:• Enable. The function is enabled (default configuration).• Disable. The function is disabled.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Related TopicsVerify/modify the threshold level of the signal at receptionVerify/modify the radio branch labelVerify/modify the generation of the antenna aiming signal

Page 98: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

96 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

SYNCHRONISATION

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Synchronisation command manages the sources and the outputs of synchronism In detail, the command allows:

Verify/modify the management of synchronisation Manage the T0 synchronism:

Verify the status and configuration of the T0 synchronismForce the status of T0 synchronisationSet the Hold Off Time parameterSet the WTR Time parameterSet the threshold levels of LTI alarm

Manage the synchronism sources:Enable/disable the use of a synchronism sourceModify the use priority of a synchronism sourceForce the use of a synchronism sourceSet a synchronism source as preferentialRestore the availability of a source for the selection of the T0 synchronism without waiting forthe expiry of Wait Time

The selection of the command displays the Synchronisation contextual area

In order to deepen this topic, see Synchronisation (info)

Verify/modify the management of synchronisation

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Synchronisation.The Synchronisation parameter indicates the management of synchronisation:

• Enabled box unchecked. Synchronisation disabled.• Enabled box checked ( ). Synchronisation enabled.

2. To change the parameter, check/uncheck the box.

3. Press Apply and confirm.

Verify the status and configuration of the T0 synchronism

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Synchronisation.The General tab displays the configuration parameters and the alarms status of the T0 synchronism.

Page 99: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 97

Force the status of T0 synchronisation

User Profile | Read & Write, Station Operator, System

WARNING Operation of maintenance (MAN. OP).

1. Select Synchronisation.The Status Control parameter indicates the status of T0 synchronism:

• Free Running. The status of Free Running is forced (synchronism T0 is generated by the equip-ment internal reference - Internal Source).

• Hold Over. The status of Hold Over is forced.• Locked. The synchronism is locked to an external source.

2. To change the parameter, select the wished option.

3. Press Apply. Only if you are activating the forcing (selection of the Free Running or Hold Over option) a messagewarns that you are executing a forcing and displays the current setting of timeout.

4. Confirm the operation. The activation of the forcing activates the MAN. OP alarm. If the equipment is switched off and, then,switched on, the forcing results inactive, independently from the previous setting.

Set the Hold Off Time parameter

User Profile | Station Operator, System

1. Select Synchronisation.The Hold Off Time parameter indicates the time (expressed in ms) during which the system keeps theevaluated frequency of an invalid synchronism source (absent or degraded).At the end of the Hold Off time, the invalid source will be rejected and it will be used the first inputsource having a valid signal.

2. To change the parameter, set in the box a value between 300 and 1800 msec.

3. Press Apply.

Set the WTR Time parameter

User Profile | Station Operator, System

1. Select Synchronisation.The WTR Time parameter indicates the time (expressed in minutes) that has to pass in such a way toallow to the selected input source having a valid signal to be really used within the process for the se-lection of T0 synchronism.

2. To change the parameter, set in the box a value between 0 and 12 minutes.

3. Press Apply.

Set the threshold levels of LTI alarm

User Profile | Station Operator, System

1. Select Synchronisation.The LTI Set Time and LTI Reset Time parameters indicate the threshold level of LTI alarm (Timing SynkLoss Alarm). In detail:

Page 100: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

98 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• LTI Set Time. Threshold value - expressed as number of consecutive seconds with the presenceof the LTI alarm - over which the system activates the alarm itself.

• LTI Reset Time. Threshold value - expressed as number of consecutive seconds without thepresence of the LTI alarm - over which the system deactivates the alarm itself.

2. To change the parameter, set the new values in the specific boxes (allowed interval between 0 and 60seconds).

3. Press Apply.

Enable/disable the use of a synchronism source

User Profile | Station Operator, System

1. Select Synchronisation.

2. Select the T0 tab.The Priority column shows the usage status of each single source.

3. To enable the use of a source, select the specific Priority box and then a number between 1 and 9 ac-cording to the desired priority level to be assigned to the source (1: maximum priority, 9: minimumpriority).To disable the use of the source, select the specific Priority box and then the Dis. value.Pressing Revert changes cancels all the changes executed.

4. Press Apply changes and confirm.

Modify the use priority of a synchronism source

User Profile | Station Operator, System

WARNING Operation available and meaningful only when the use of the synchronism source is active.

1. Select Synchronisation.

2. Select the T0 tab.The Priority column shows the priority level of each single source.

3. To change the priority level of a source, select the specific Priority box and then a number between 1and 9 according to the desired priority level to be assigned to the source (1: maximum priority, 9: min-imum priority).Pressing Revert changes cancels all the changes executed.

4. Press Apply changes and confirm.

Force the use of a synchronism source

User Profile | Read & Write, Station Operator, System

WARNING Operation of maintenance (MAN. OP).Operation meaningful only when the use of the synchronism source is active.

1. Select Synchronisation.

2. Select the T0 tab.The Forced Switch column shows the forcing status of each single source.

3. To change the forcing status of a source, select the specific Forced Switch box and then the option:• Off, not to force the use of the source for the generation of the synchronism.

Page 101: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 99

• On, to force the use of the source for the generation of the synchronism.Pressing Revert changes cancels all the changes executed.

4. Press Apply changes.Only if you are activating the forcing a message warns that you are executing a forcing and displaysthe current setting of timeout.

5. Confirm the operation. The activation of the forcing activates the MAN. OP alarm. If the equipment is switched off and, then,switched on, the forcing results inactive, independently from the previous setting.

Set a synchronism source as preferential

User Profile | Station Operator, System

WARNING Operation meaningful only when the use of the synchronism source is active.

1. Select Synchronisation.

2. Select the T0 tab.The Preferential Switch column shows if the source is used as preferential.

3. To change the preferential status of a source, select the specific Preferential Switch box and then theoption:

• Off. The synchronism source is not preferential as opposed to the other enabled synchronismsources.

• On. The synchronism source is preferential as opposed to the other enabled synchronism sourc-es and (in absence of alarms causing its degrade or forced sources) is used for the generationof the synchronism.

Pressing Revert changes cancels all the changes executed.

4. Press Apply changes and confirm.

Restore the availability of a source for the selection of the T0 synchronism without waiting for the expiry of Wait Time

User Profile | Station Operator, System

WARNING Operation meaningful only when the use of the synchronism source is active.

1. Select Synchronisation.

2. Select the T0 tab.

3. Select the source, with valid signal, whose availability you wish to restore for the generation of T0 syn-chronism.

4. Press WTR Clear and confirm.The source is immediately used for the generation of T0 synchronism. The period Wtr Time is consid-ered elapsed.

Page 102: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

100 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Synchronisation contextual area

In the contextual area is present the:General tab. The tab displays the configuration parameters and the alarms status of T0 synchronism.T0 tab. The tabs display the configuration parameters and the status of the synchronism sources.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Related TopicsSynchronisation (info)

General tab

The tab displays the configuration parameters and the alarms status of T0 synchronism.

Alarms area. Alarms status of the T0 synchronism (Free Running, Hold Over and T0 boxes). The colourof each box displays the status of the specific alarm:

• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-jor, Minor, Warning severity.

• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

Synchronisation (Settings area). Management of synchronisation. Enabled box:• Unchecked. Synchronisation disabled.• Checked ( ). Synchronisation enabled.

Status Control (Settings area). Status of T0 synchronism:• Free Running. The status of Free Running is forced (synchronism T0 is generated by the

equipment internal reference - Internal Source).• Hold Over. The status of Hold Over is forced.• Locked. The synchronism is locked to an external source.

Hold Off Time (area Time). Time (expressed in ms) during which the system keeps the evaluated fre-quency of an invalid synchronism source (absent or degraded). At the end of the Hold Off time, theinvalid source will be rejected and it will be used the first input source having a valid signal.

WTR Time (area Time). Time (expressed in minutes) that has to pass in such a way to allow to theselected input source having a valid signal to be really used within the process for the selection of T0synchronism.

LTI Set Time / LTI Reset Time (area Time). Threshold level of LTI alarm (TimingSynkLossAlarm). Indetail:

• LTI Set Time. Threshold value - expressed as number of consecutive seconds with the pres-ence of the LTI alarm - over which the system activates the alarm itself.

• LTI Reset Time. Threshold value - expressed as number of consecutive seconds without thepresence of the LTI alarm - over which the system deactivates the alarm itself.

Related TopicsForce the status of T0 synchronisationSet the Hold Off Time parameterSet the WTR Time parameterSet the threshold levels of LTI alarm

Page 103: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 101

T0 tab

The tabs display the configuration parameters and the status of the synchronism sources.The table present in the specific tab displays the sources for T0 synchronism. Every table row correspondsto one source, for which is pointed out in the column:

Name. Synchronism source name:• TE LAN-1. Source extracted from the LAN 1 of Ethernet Switch (electrical or optical inter-

face).• TE LAN-2. Source extracted from the LAN 2 of Ethernet Switch (electrical interface).• T2 Radio. Source extracted from the Radio 1A.• Internal. Source extracted from an its own internal reference (12,8MHz STRATUM 3). The

Internal source has not configuration parameters.If the TE LAN-1 and TE LAN-2 sources are not available, this means that the SyncE functionality is notenabled for the equipment (see Verify the functionalities enabled for the equipment).

Priority. Status and priority use of the source:• Dis. The synchronism source is not used.• <1 ÷ 9>. The synchronism source is enabled and has a priority level pointed out by the num-

ber (1: maximum priority, 9: minimum priority).

Forced Switch. Forced use of the source:• Off. The source has not been manually forced for the generation of T0 synchronism. • On <light blue box>. The source has been manually forced for the generation of T0 synchro-

nism (Manual Operation).

Preferential Switch. Status of preferential usage of the source:• Off. The synchronism source is not preferential as opposed to the other enabled synchronism

sources.• On. The synchronism source is preferential as opposed to the other enabled synchronism

sources and (in absence of alarms causing its degrade or forced sources) is used for the gen-eration of the synchronism.

Sync Loss / Sync Drift. Respectively status of the alarm Timing Synk Loss Alarm and Timing SynkDrift Alarm relevant to the source. The colour of each box displays the status of the specific alarm:

• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-jor, Minor, Warning severity.

• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

The source of synchronism whose row has red border indicates the source which the equipment extractsthe synchronization T0 from.When the source, which the synchronization is extracted from, changes, the row relevant to the new sourcewill become yellow and will blink before taking the red border.

Push-button:Refresh. Update the context.Apply changes. Confirm the changes.Revert changes. Cancel the changes not confirmed yet.WTR Clear. Restore the availability of a source for the selection of the T0 synchronism without waitingfor the expiry of Wait Time.

Related TopicsEnable/disable the use of a synchronism sourceModify the use priority of a synchronism sourceForce the use of a synchronism sourceSet a synchronism source as preferential

Page 104: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

102 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Synchronisation (info)

Management of synchronisationSynchronism sources

Enabling of the synchronism sourcesPriority of the synchronism sourceForcing of a synchronism sourceFunction of preferential synchronism source

Internal synchronism T0

Management of synchronisation

ALFOplus80 equipment can be configured to operate with synchronisation enabled or disabled.When the synchronisation is disable, the synchronisation is not managed: the clocks are generated by thelocal internal reference.When the synchronisation is enabled, the synchronism source, enabled with the highest priority, is usedto synchronise the equipment (if a forcing or a preferential is not active).The user can enable or disable the management of synchronisation as he wishes (see Synchronisation).

Synchronism sources

The equipment has more synchronism sources.TE LAN-1. Source extracted from the LAN 1 of Ethernet Switch (electrical or optical interface).TE LAN-2. Source extracted from the LAN 2 of Ethernet Switch (electrical interface).T2 Radio. Source extracted from the Radio 1A.Internal. Source extracted from an its own internal reference (12,8MHz STRATUM 3).

WARNING If the TE LAN-1 and TE LAN-2 sources are not available, this means that the SyncE functionalityis not enabled for the equipment (see Verify the functionalities enabled for the equipment).

Enabling of the synchronism sources

A synchronism source, in order to be used, must be enabled by the user (see Enable/disable the use of asynchronism source).

Priority of the synchronism source

A priority level can be associated to every synchronism source (see Modify the use priority of a synchronismsource).

The source with the highest priority level and whose signal is valid, is used to synchronize the equipment(if a forcing or a preferential source is not active).

The priority level of the synchronism source is pointed out by a number between 1 and 9, where 1 indicatesthe highest priority and 9 the lowest one.

Generally the equipment takes the synchronism from the source with the highest priority level: if thissource is missing or is degraded, the synchronism is taken from the source with priority level immediatelylower.

Page 105: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 103

When the source with highest priority level returns to be valid, the equipment after the WTR time will au-tomatically start to use it to take the synchronism. If all the synchronism sources (set by the user) becomeunavailable, the equipment automatically takes the synchronism from its own internal reference.

The degradation of the signal is caused by the presence of, at least, one of the following conditions:• The source is not physically present.• The difference between the source frequency and the internal reference source (STRATUM 3) is

greater than ± 7 ppm.

If two or more sources with the same priority are activated, these sources will be inserted into a circularand not Revertive list.

Forcing of a synchronism source

This function foresees the user can force the selection of one synchronism source (see Force the use of asynchronism source).

This forcing is made without considering the status and the priority of the source.

This function must not be used for the normal operation of the synchronism. It is a maintenance operationand remains active until the user disables it or the Timeout period of the manual operations expires (if set).

Function of preferential synchronism source

This function foresees the choice of a source to use as preferential among those enabled (see Set a syn-chronism source as preferential).

When the function of preferential source is not active, the internal synchronism is taken from the enabledsource with highest priority.

When the function of preferential source is activated for a source, this source will be used (in absence ofalarms causing its degradation or forced sources) to take the internal synchronism independently from itspriority level.

This condition is maintained until when the user disables the function of preferential source or the sourcesignal becomes degraded.

Internal synchronism T0

The synchronism source, which the internal synchronism T0 is extracted from, is determined by the SETSof the equipment according to the following order of criteria:

• Status of the source (enabled/disabled)• Forcing of the source• Status of the signal (valid/degraded)• Preferential source• Source priority

The internal synchronism T0 can assume one of the following statuses:• Free Running. The status of Free Running is forced (synchronism T0 is generated by the equip-

ment internal reference - Internal Source).• Hold Over. The status of Hold Over is forced.• Locked. The synchronism is locked to an external source.

The user can force the status of the internal synchronism T0 (see Force the status of T0 synchronisation).The forcing of the status Hold Over or Free Running is not the normal operation of the synchronism T0.These forcings are maintenance operations and remain active until when the user does not disable themor the Timeout period of the manual operation expires (if set).

Page 106: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

104 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

BASE BAND

Ethernet Switch. It manages the general configuration of the Ethernet functionality.LAN 1, LAN 2. It manages the Ethernet external ports. Port A. It manages the Ethernet internal port.

Page 107: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 105

Ethernet Switch

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Setting a specific management configuration introduces some restrictions on the setting of theEthernet Switch parameters (see Management configurations (info) and Tab.3).

Ethernet Switch command manages the general configuration parameters of the Ethernet functionality.In detail, the command allows:

GENERAL SETTINGS OF ETHERNET SWITCH

Verify/modify the Eth Type value in the S_Tag QinQ fieldVerify/modify the maximum size of the accepted packetVerify/modify the address learning modality in MAC TableVerify/modify the aging time of the addresses stored in the MAC TableReset the MAC TableVerify/modify the emptying algorithm of the packets present in the output queueVerify/assign the output queue to a packet according to its Tag 802.1p (level 2)Verify/modify the hysteresis of the Link Loss Forwarding modality

PTOS/DSCP PRIORITY PARAMETERS

Verify/assign the output queue to a packet according to its PTOS/DSCP field (level 3)

VIRTUAL LANVerify the existing virtual LANsCreate a virtual LanModify the configuration of a virtual LanDelete a virtual Lan

The selection of the command displays the Ethernet Switch contextual area

In order to deepen this topic, see Ethernet Switch (info)

Verify/modify the Eth Type value in the S_Tag QinQ field

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Ethernet Switch.The QinQ ETH Type 0x parameter indicates the Eth Type value in the S_Tag (Service Tag) QinQ field.

2. To change the parameter, type the new value.

3. Press Apply and confirm.

Verify/modify the maximum size of the accepted packet

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The Max Packet Size parameter is evaluated in a different way for electrical and optical ODUversion.In electrical version the max packet size configured by the user is intended as packet size including theVLAN Tag (4 bytes) possibly added on radio port egress (Fallback-Provider mode) or LAN egress (Providermode). For example, if the Max Packet Size parameter is set to 1522 the max packet size admitted to betransported is 1518 bytes.

Page 108: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

106 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

In optical version the max packet size configured by the user is intended as packet size excluding the VLANTag (4 bytes) possibly added on radio port or LAN egress. For example, if the Max Packet Size parameteris set to 1522 the max packet size admitted to be transported is 1522 bytes.When the in-band supervision is active (see Port Configuration) and the Double Tag function is enabled(see LAN 1, LAN 2/Port A), for the correct transit of the supervision packets it is suggested to set the value2048 as maximum packet size.

1. Select Base Band > Ethernet Switch.The Max Packet Size parameter indicates the maximum size (in bytes) of the accepted packet:

• 1522. Maximum size for standard Ethernet (IEEE Tagged Frames). • 2048. Maximum dimension of the packet extendable up to 2048.• 10240 (Jumbo). Maximum dimension of the packet extendable up to 10240 (Jumbo).

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the address learning modality in MAC Table

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING If some VLANs have been already created, when the partition and the indexing on VID (VLANIdentifier) basis of the addresses in MAC Table (selection of option Enable), IT IS NECESSARY to executea software reset.

1. Select Base Band > Ethernet Switch.The parameter MAC Learning Vid basis indicates the address learning modality of MAC address in therelevant table:

• Disable. Learning of MAC Address in MAC Table is never partitioned in presence of VLAN 802.1Qregistered in VLAN Table Unit (VTU).

• Enable. The partition and the indicization on VID basis of MAC Addresses in MAC Table are en-abled. Their learning is registered in a segment of MAC Table whose index is the value of VIDcontained in the VLANs entering the Switch and registered in VTU.

2. To change the parameter, select the wished value.

3. Press Apply and confirm.

Verify/modify the aging time of the addresses stored in the MAC Table

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Ethernet Switch.The MAC Addr. Aging Time parameter indicates the validity period of the MAC addresses, dynamicallyacquired and stored in the specific table.

2. To change the parameter, set the wished value (numeric value between 15 and 3825 seconds).

3. Press Apply and confirm.

Reset the MAC Table

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Press Mac Table clear and confirm.The system resets the MAC Table.

Page 109: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 107

Verify/modify the emptying algorithm of the packets present in the output queue

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.The Egress Priority Policy parameter indicates the emptying algorithm of the output queues:

• Strict Priority, the queue with highest priority is completely emptied (sending of all the messag-es) before sending a message of the queue with lower priority.

• 8421 WRR, a part (8 messages) of the queue with highest priority is empties, then a part of thequeue with lower priority (4 messages), then a part of the queue with further lower priority (2messages), then a part of the queue with lowest priority (1 message) and so on restarting fromthe queue with highest priority.

• Strict 3, the high priority queue 3 is completely emptied (sending of all the messages). The otherqueues (2, 1, 0) are managed with a WRR 421 mechanism.

• Strict 3 and 2, the high priority queue 3 and queue 2 are completely emptied. The other queues(1, 0) are managed with a WRR 21 mechanism.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/assign the output queue to a packet according to its Tag 802.1p (level 2)

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.The 802.1p Priority Management table indicates which output queue a packet, in input to any Ethernetport, must be assigned to, depending on its 802.1p priority Tag.The rows of the table correspond to the output queue available in the equipment. Each Ethernet portof the equipment has four output queue, which the packets in input from other ports are sent to:

• Queue 0. Queue with 0 priority (low priority).• Queue 1. Queue with 1 priority.• Queue 2. Queue with 2 priority. • Queue 3. Queue with 3 priority (high priority).

The columns of the table (0 ÷ 7) correspond to the Tag 802.1p value of the packet in input to a portof the equipment.The active option indicates which output queue (Queue…) the packet in input is associated to, whosevalue of priority Tag (802.1p) corresponds to the value 0, 1, 2, 3, 4, 5, 6 or 7. The 802.1p Priority Management table is COMMON to all the Ethernet port of the equipment.

2. To change the parameter, select the option corresponding to the wished combination output queue -Tag 802.1p.For the same value of Tag 802.1p, it is possible to select only one queue at a time.

3. Press Apply and confirm.

Verify/assign the output queue to a packet according to its PTOS/DSCP field (level 3)

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The setting of the parameters is common to all the ports of the Ethernet Switch.

1. Select Base Band > Ethernet Switch.

2. Select the PTOS/DSCP Config tab.

The table present in the tab displays, for each PTOS/DSCP value, the relevant output queue.Every row of the table corresponds to a possible value for the relevant PTOS/DSCP field. For every val-ue, is pointed out in the column:

Page 110: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

108 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Value. The value expressed in binary digits.• Precedence, Delay, Throug., Reliab., DSCP. For the description of the parameter present in these

columns refer to RFC 2474, 2597 and 2598 (Request For Comments). • Internal Priority (Queue). The queue which the packet in input to the specific port, whose PTOS/

DSCP has the value displayed in the row, is assigned to is displayed:• Queue 0. Output queue with 0 priority (low priority). • Queue 1. Output queue with 1 priority. • Queue 2. Output queue with 2 priority. • Queue 3. Output queue with 3 priority (high priority).

The List Filter parameter allows to activate the filters to the list of value. If set the option: • View All. The list displays all the values. • View Queue 0. The list displays only the values associated to the 0 output queue. • View Queue 1. The list displays only the values associated to the 1 output queue.• View Queue 2. The list displays only the values associated to the 2 output queue.• View Queue 3. The list displays only the values associated to the 3 output queue.

To modify the displaying of the list, select the wished values.

The Filter parameter allows to set the IP format which the DSCP field refers to:• IP v4 DSCP. The DSCP column is meaningful for traffic incoming in the Switch in the IPv4 format.• IP v6 DSCP. The DSCP column is meaningful for traffic incoming in the Switch in the IPv6 format.

3. To modify the output queue, which a PTOS/DSCP value is associated to, select, in the Filter box, the IPformat which the DSCP field refers to.

4. Double click on the box (column Internal Priority (Queue) relevant to the output queue you wish tochange and select the wished option.

5. Repeat the previous step to change the output queue of all the wished PTOS/DSCP value.

6. Press Apply and confirm.

Verify/modify the hysteresis of the Link Loss Forwarding modality

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Select the LLF tab.The LLF Hysteresis parameter indicates the time interval (hysteresis) after which the Link Loss Forward-ing modality is activated and deactivated.

3. To change the parameter, move the cursor to the wished value.

4. Press Apply and confirm.

Verify the existing virtual LANs

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Select the Virtual Lan Config. tab.The tab displays the existing virtual LANs.

Page 111: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 109

Create a virtual Lan

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Select the Virtual Lan Config. tab.

3. Press Add.

4. Type, in VLan ID box, the identifier (within 2 and 4094) you wish to assign to the virtual LAN.The parameter cannot be modified later.

5. If you wish to create more VLAN’s at the same time, type in the End Block box the identifier of the lastVLAN of the group (between 2 and 4094).The value of End Block must be greater than the value of VLan ID and no VLAN with identifier withinthe range End Block - VLan ID must be present in the list.The system creates a number of VLAN’s (and inserts the relevant rows in the table) equal to the differ-ence between the values of the parameters End Block and VLan ID, with identifiers in progression fromthe lowest to the higher value, and automatically assigns the relevant Label using the format <Label><identifier>.All the VLANs created at the same time get the same policy regarding the transit of packets throughthe ports of the Ethernet switch.

6. Type, in Label box, the name (alphanumeric string up to 20 characters) you wish to assign to the virtualLAN.The system automatically suggest, as name of the virtual Lan, Vlan <identifier>. This name can bechanged as you wish.

7. In the box relevant to each external port (Lan 1, Lan 2) and internal port (Port A), select the option: • Disable, not to enable the port for the transit of the packets with VLan ID equal to that of the

virtual Lan.• Tagged, to enable the port to the transit of the packets with VLan ID equal to that of the virtual

Lan. To the packets without Tag, in output from this port, is automatically added the Tag com-posed by the information:

• Of priority; the value is defined in the Priority box of the origin port of the packet itself. • Of Vlan ID which corresponds to the default Vlan ID (Default Vid box) of the origin port

of the packet.The Vlan Table can be used, in case of traffic without Tag, only if the default Vlan ID of the inputport is contained as routing row in the table itself. If this condition is not satisfied, the Vlan Tableis not meaningful for all the traffic without Tag.

• Untag., to enable the port to the transit of the packets with VLan ID equal to that of the virtualLan. The tag 802.1Q (information of priority and VLAN identifier) is removed to the packets inoutput from the port.

• Unmodif., to enable the port to the transit of the packets with VLan ID equal to that of the virtualLan. The tag 802.1Q (priority and VLAN identifier) are not removed or added to the packets inoutput from the port.

In order to create the VLAN, the transit of the packets must be enabled at least for one port (a valuedifferent from Disable is set).

8. Press Apply and confirm.The Virtual Lan Config. tab displays the row relevant to the new virtual Lan.If the displayed message is:

• Warning! VLAN ID already in the list. The set identifier corresponds to that of an already existingVLAN. Change the value in the VLan ID box.

• The command is rejected to save system reachability. The operation is rejected not to compro-mise the system reachability. Verify that the made settings are compatible with the manage-ment configuration set for the equipment (see Tab.3).

Page 112: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

110 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Modify the configuration of a virtual Lan

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Select the Virtual Lan Config. tab.

3. Double click on the box relevant to the parameter of VLan you wish to change.Except for the identifier (VLAN ID), all the parameters of a VLan can be modified (Label, Lan 1, Lan 2,Port A). The parameter setting modes are the same pointed out in par. Create a virtual Lan.Pressing Revert changes cancels all the changes executed and not communicated yet to the equip-ment.

4. Press Apply changes and confirm.The changes are confirmed in Virtual Lan Config tab. If the displayed message is:

• The command is rejected to save system reachability. The operation is rejected not to compro-mise the system reachability. Verify that the made settings are compatible with the manage-ment configuration set for the equipment (see Tab.3).

Delete a virtual Lan

User Profile | Station Operator, System

1. Select Base Band > Ethernet Switch.

2. Select the Virtual Lan Config. tab.

3. Select the virtual Lan you wish to delete.The multiple selection can be executed using the Ctrl or Shift keys.

4. Press Remove and confirm.The selected virtual Lans are removed from the list. If the displayed message is:

• The command is rejected to save system reachability. The operation is rejected not to compro-mise the system reachability. Verify that the made settings are compatible with the manage-ment configuration set for the equipment (see Tab.3).

Page 113: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 111

Ethernet Switch contextual area

In the contextual area is present the:General tab. The tab displays the general configuration parameters of the Ethernet Switch. LLF tab. The tab displays the hysteresis of the Link Loss Forwarding modality.PTOS/DSCP Config. tab. The tab displays, for each PTOS/DSCP value, the relevant output queue.Virtual Lan Config. tab. The tab displays the existing virtual LANs.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Related TopicsEthernet Switch (info)

General tab

The tab displays the general configuration parameters of the Ethernet Switch.

QinQ ETH type 0x. Eth Type value in the S_Tag (Service Tag) QinQ field

Max Packet size. Maximum size (in bytes) of the accepted packet:• 1522. Maximum size for standard Ethernet (IEEE Tagged Frames). • 2048. Maximum dimension of the packet extendable up to 2048.• 10240 (Jumbo). Maximum dimension of the packet extendable up to 10240 (Jumbo).

MAC Learning Vid basis. Address learning modality of MAC address in the relevant table:• Disable. The learning of MAC Address in MAC Table is never partitioned in presence of VLAN

802.1Q registered in VLAN Table Unit (VTU).• Enable. The partition and the indicization on VID (VLAN Identifier) basis of MAC Addresses

in MAC Table are enabled. Their learning is registered in a segment of MAC Table whose in-dex is the value of VID contained in the VLANs entering the Switch and registered in VTU.

MAC Addr. Aging Time. Validity period of the MAC addresses, stored in the MAC Table.

Egress Priority Policy. Emptying algorithm of the packets present in the output queue: • 8421 WRR, indicates that a part (8 messages) of the queue with highest priority is empties,

then a part of the queue with lower priority (4 messages), then a part of the queue with fur-ther lower priority (2 messages), then a part of the queue with lowest priority (1 message)and so on restarting from the queue with highest priority.

• Strict Priority, indicates that the queue with highest priority is completely emptied (sendingof all the messages) before sending a message of the queue with lower priority.

• Strict 3, indicates that the high priority queue 3 is completely emptied (sending of all themessages). The other queues (2, 1, 0) are managed with a WRR 421 mechanism.

• Strict 3 and 2, indicates that the high priority queue 3 and queue 2 are completely emptied.The other queues (1, 0) are managed with a WRR 21 mechanism.

802.1p Priority Management. This table indicates which output queue a packet, in input to anyEthernet port, must be assigned to, depending on its 802.1p priority Tag.The rows of the table correspond to the output queue available in the equipment. Each Ethernet portof the equipment has four output queue, which the packets in input from other ports are sent to:

• Queue 0. Queue with 0 priority (low priority).• Queue 1. Queue with 1 priority.• Queue 2. Queue with 2 priority. • Queue 3. Queue with 3 priority (high priority).

Page 114: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

112 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

The columns of the table (0 ÷ 7) correspond to the Tag 802.1p value of the packet in input to a portof the equipment.The active option indicates which output queue (Queue…) the packet in input is associated to, whosevalue of priority Tag (802.1p) corresponds to the value 0, 1, 2, 3, 4, 5, 6 or 7. The 802.1p Priority Management table is COMMON to all the Ethernet port of the equipment.

Push-button:Mac Table clear. Reset the MAC Table.

Related TopicsVerify/modify the Eth Type value in the S_Tag QinQ fieldVerify/modify the maximum size of the accepted packetVerify/modify the address learning modality in MAC TableVerify/modify the aging time of the addresses stored in the MAC TableVerify/modify the emptying algorithm of the packets present in the output queueVerify/assign the output queue to a packet according to its Tag 802.1p (level 2)

LLF tab

The tab displays the hysteresis of the Link Loss Forwarding modality.

LLF Hysteresis. Time interval (hysteresis) after which the Link Loss Forwarding modality is activatedand deactivated.

Related TopicsVerify/modify the hysteresis of the Link Loss Forwarding modality

PTOS/DSCP Config. tab

The table present in the tab displays, for each PTOS/DSCP value, the relevant output queue.Every row of the table corresponds to a possible value for the relevant PTOS/DSCP field. For every value,is pointed out in the column:

Value. The value expressed in binary digits.

Precedence, Delay, Throug., Reliab., DSCP. For the description of the parameter present in thesecolumns refer to RFC 2474, 2597 and 2598 (Request For Comments).

Internal Priority (Queue). The queue which the packet in input to the specific port, whose PTOS/DSCP has the value displayed in the row, is assigned to is displayed:

• Queue 0. Output queue with 0 priority (low priority). • Queue 1. Output queue with 1 priority. • Queue 2. Output queue with 2 priority. • Queue 3. Output queue with 3 priority (high priority).

The List Filter parameter allows to activate the filters to the list of value. If set the option: • View All. The list displays all the values. • View Queue 0. The list displays only the values associated to the 0 output queue. • View Queue 1. The list displays only the values associated to the 1 output queue.• View Queue 2. The list displays only the values associated to the 2 output queue.• View Queue 3. The list displays only the values associated to the 3 output queue.

To change the displaying of the list, select the wished values.

Page 115: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 113

The Filter parameter allows to set the IP format which the DSCP field refers to:• IP v4 DSCP. The DSCP column is meaningful for traffic incoming in the Switch in the IPv4 format.• IP v6 DSCP. The DSCP column is meaningful for traffic incoming in the Switch in the IPv6 format.

Related TopicsVerify/assign the output queue to a packet according to its PTOS/DSCP field (level 3)

Virtual Lan Config. tab

The table present in the tab, displays the existing virtual LANs.Every row of the table corresponds to a VLAN for which is pointed out in the column:

VLan ID. Identifier assigned to the virtual Lan by the user during its creation.

Label. Name assigned to the virtual Lan by the user during its creation or modification.

Lan1. Enabling of the LAN 1 to the transit of packets with VLan ID equal to that of the virtual LAN: • Disable. The port is not enabled to the transit of the packets with VLan ID equal to that of

the virtual Lan. • Untag. The port allows the transit of the packets with VLan ID equal to that of the virtual

Lan. The tag 802.1Q (information of priority and VLAN identifier) is removed to the packetsin output from the port.

• Tagged. The port is enabled to the transit of the packets with VLan ID equal to that of thevirtual Lan. To the packets without Tag, in output from this port, is automatically added theTag composed by the information:

• Of priority; the value is defined in the Priority box of the origin port of the packet it-self.

• Of Vlan ID which corresponds to the default Vlan ID (Default Vid box) of the originport of the packet.

The Vlan Table can be used, in case of traffic without Tag, only if the default Vlan ID of theinput port is contained as routing row in the table itself. If this condition is not satisfied, theVlan Table is not meaningful for all the traffic without Tag.

• Unmodif. The port is enabled to the transit of the packets with VLan ID equal to that of thevirtual Lan. The tag 802.1Q (priority and VLAN identifier) are not removed or added to thepackets in output from the port.

Lan2. Enabling of the LAN 2 to the transit of packets with VLan ID equal to that of the virtual LAN. Forthe description of the values, refer to the Lan1 note.

PortA. Enabling of the internal port to the transit of packets with VLan ID equal to that of the virtualLAN. For the description of the values, refer to the Lan1 note.

The Default VLan ID area displays the default VLan identifier of each Ethernet port of the equipment.

Push-button:Add. Create a virtual Lan.Remove. Delete a virtual Lan.Apply changes. Confirm the changes made to VLANs.Revert changes. Cancel the changes made to VLANs and not confirmed yet.

Related TopicsModify the configuration of a virtual Lan

Page 116: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

114 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Ethernet Switch (info)

Limitations in the configuration of the Ethernet SwitchAddition of S-TAG (QinQ – Double Tag) in a packet with C-TAGAnalysing the priority MAC Table

Limitations in the configuration of the Ethernet Switch

The ports of the Ethernet Switch of ALFOplus80 equipment can be configured for the transport of the trafficonly or for the contemporary transport of traffic and supervision (see Management configurations (info).Setting a specific management configuration introduces some restrictions on the setting of the EthernetSwitch parameters, as indicated in Tab.3, Tab.4, Tab.5 e Tab.6.

Tab.3 Restrictions on the Switch Ethernet parameters vs. management configuration

Key. LAO Local Access Only. OOB Out Of Band. NR No Restriction.

(1) Static VLANs, not removable.(1) During the creation of VLAN, LAN 2 must be set to Disable. Any other setting will involve the rejectionof the operation.(2) When the management configuration is activated, the following (not removable) VLANs are created:

• VLan ID 101 - LAN 1 (Unmodified) - LAN 2 (Disable) - Port A (Unmodified).• VLan ID 1 - LAN 1 (Disable) - LAN 2 (Unmodified) - Port A (Unmodified).

(3) When the management configuration is activated, the following (not removable) VLANs are created:• VLan ID 101 - LAN 1 (Unmodified) - LAN 2 (Disable) - Port A (Unmodified).• VLan ID <In Band VLan Id value> - LAN 1 (Unmodified) - LAN 2 (Untagged) - Port A (Unmodi-

fied).(4) When the management configuration is activated, the following (not removable) VLANs are created:

• VLan ID 101 - LAN 1 (Unmodified) - LAN 2 (Disable) - Port A (Unmodified).• VLan ID <In Band VLan Id value> - LAN 1 (Tagged) - LAN 2 (Untagged) - Port A (Tagged).

(5) When the management configuration is activated, the following (not removable) VLANs are created:• VLan ID 101 - LAN 1 (Unmodified) - LAN 2 (Unmodified) - Port A (Unmodified).• VLan ID 102 - LAN 1 (Unmodified) - LAN 2 (Unmodified) - Port A (Unmodified).• VLan ID <In Band VLan Id value> - LAN 1 (Unmodified) - LAN 2 (Unmodified) - Port A (Unmod-

ified).

SwitchEthernet

parameter

Management configuration

Lan1 DisabledLan2 LAO

Lan1 DisabledLan2 OOB

Lan1 In BandLan2 LAO

Lan1 In BandLan2 Drop Node

Lan1 In BandLan2 In Band

Lan1 In BandLan2 Disabled

General tab

All NR NR NR NR NR NR

LLF tab

LLF Hysteresis NR NR NR NR NR NR

PTOS/DSCP Config. tab

All NR NR NR NR NR NR

Virtual Lan Config. tab

VLAN Table (1) (1) (2) (1) (3) (1) (4) (5) (5)

Page 117: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 115

Tab.4 Restrictions on the LAN 1 parameters vs. management configuration

Key. LAO Local Access Only. OOB Out Of Band. NR No Restriction. RO Read Only (unchangeable param-eter). A Value automatically set at the activation of the management configuration.

LAN 1parameter

Management configuration

Lan1 DisabledLan2 LAO

Lan1 DisabledLan2 OOB

Lan1 In BandLan2 LAO

Lan1 In BandLan2 Drop Node

Lan1 In BandLan2 In Band

Lan1 In BandLan2 Disabled

Interface tab

Master/Slave NR NR NR NR NR NR

M/Sautonegotiation

NR NR NR NR NR NR

Rate Control NR NRA Full Rate

Full RateRO

Full RateRO

Full RateRO

Full RateRO

Flow Control NR NR NR NR NR NR

Cable Crossover NR NR NR NR NR NR

Mac Learning NR NR NR NR NR NR

Speed/Duplex NR NR NR NR NR NR

802.1Q Management tab

Default VID NRA 101

NRA 101

NRA 101

NRA 101

NRA 101

NRA 101

802.1Q Setting NR NRA Disabled

Disabled notallowed

A Fallback

Disabled notallowed

A Fallback

NRA Fallback

NRA Fallback

Traffic Treatment Transparent Port to Port Transport

RO

Transparent Port to Port Transport

RO

Transparent Port to Port Transport

RO

TransparentPort to PortTransport

RO

NRA Transparent

Bridge PortBased

NRA Transparent

Bridge PortBased

Selective Provider Tag

NR NR NRA Disable

NRA Disable

NRA Disable

NRA Disable

Port Based VLAN tab

LAN2 DisableRO

DisableRO

DisableRO

EnableRO

NRA Enabled

NRA Enabled

Port A NR NR NRA Enabled

NRA Enabled

NRA Enabled

NRA Enabled

Priority Management tab

All NR NR NR NR NR NR

LLF tab

All NR NR NRA Disable

NRA Disable

NRA Disable

NRA Disable

Line Loop tab

All NR NR NRA Disable

NRA Disable

NRA Disable

NRA Disable

Laser Control tab

All NR NR NR NR NR NR

Page 118: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

116 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Tab.5 Restrictions on the LAN 2 parameters vs. management configuration

Key. LAO Local Access Only. OOB Out Of Band. NR No Restriction. RO Read Only (unchangeable param-eter). A Value automatically set at the activation of the management configuration.

LAN 2parameter

Management configuration

Lan1 DisabledLan2 LAO

Lan1 DisabledLan2 OOB

Lan1 In BandLan2 LAO

Lan1 In BandLan2 Drop Node

Lan1 In BandLan2 In Band

Lan1 In BandLan2 Disabled

Interface tab

Master/Slave NR NR NR NR NR NR

M/Sautonegotiation

NR NR NR NR NR NR

Rate Control Full RateRO

Full RateRO

Full RateRO

Full RateRO

Full RateRO

NR

Flow Control NR NR NR NR NR NR

Cable Crossover NR NR NR NR NR NR

Mac Learning DisableRO

NR DisableRO

NR NR NR

Speed/Duplex NR NR NR NR NR NR

802.1Q Management tab

Default VID NRA 102

1RO

ValueIn Band VLan Id

RO

ValueIn Band VLan Id

RO

NRA 102

NRA 102

802.1Q Setting NRA Disabled

DisabledRO

SecureRO

SecureRO

NRA Fallback

NRA Fallback

Traffic Treatment Transparent Port to Port Transport

RO

Transparent Port to Port Transport

RO

Transparent Port to Port Transport

RO

TransparentPort to PortTransport

RO

NRA Transparent

Bridge Port Based

NRA Transparent

Bridge Port Based

Selective Provider Tag

NRA Disable

DisableRO

DisableRO

DisableRO

NRA Disable

NRA Disable

Port Based VLAN tab

LAN1 DisableRO

DisableRO

DisableRO

EnableRO

NRA Enabled

NRA Enabled

Port A DisableRO

NRA Enable

DisableRO

NRA Enable

NRA Enable

NRA Enable

Priority Management tab

Priority Selection Port DefaultRO

NRA Port Default

Port DefaultRO

Port DefaultRO

NR NR

Default Priority 7RO

NRA 7

7RO

7RO

NR NR

802.1p Remapping - NR - - NR NR

LLF tab

All DisableRO

DisableRO

DisableRO

DisableRO

NRA Disable

NR

Line Loop tab

Line Loop DisableRO

DisableRO

DisableRO

DisableRO

NRA Disable

NR

Page 119: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 117

Tab.6 Restrictions on the Port A parameters vs. management configuration

Key. LAO Local Access Only. OOB Out Of Band. NR No Restriction. RO Read Only (unchangeable param-eter). A Value automatically set at the activation of the management configuration.

Addition of S-TAG (QinQ – Double Tag) in a packet with C-TAG

This functionality allows adding a second TAG (S-TAG) in output to an already tagged packet in input, onthe basis of the values of the port in input.Necessary conditions are:

• The input/radio ports of the local switch are configured in Fallback and the output ports of re-mote switch in Fallback (Provider Enable).

• In VLAN table, a VLAN is configured equal to the parameter Default Vid of the port in input, de-fined as Unmodified for the input port and Tagged for the port in output.

The S-TAG added to the packet in output from the switch will be composed by:• Ethernet Type defined in Ethernet Switch QinQ Eth type (default 0x9100)• Default VID of the input port which the packet comes from.• Default Pbit of the input port which the packet comes from, if 802.1p is disabled• Origin Pbit (possibly re-mapped) of the packet in input if 802.1p is enabled (or remapping is

enable)Notes:

• When the Switch works at S-TAG level, C-TAG is left unchanged.

Analysing the priority

The equipment allows analysing the priority at level 2, according to the standard 802.1p (values 0…7), orat level 3 (PTOS/DSCP field).

Porta Aparameter

Management configuration

Lan1 DisabledLan2 LAO

Lan1 DisabledLan2 OOB

Lan1 In BandLan2 LAO

Lan1 In BandLan2 Drop Node

Lan1 In BandLan2 In Band

Lan1 In BandLan2 Disabled

Interface tab

Port NR NR NR NR NR NR

Flow Control NR NR NR NR NR NR

MAC Learning NR NRA Enable

NR NR NR NR

802.1q Management tab

Ingress Filtering Check

NR FallbackRO

NRA Fallback

NRA Fallback

NRA Fallback

NRA Fallback

Default VID NR 111RO

NRA 111

NRA 111

NRA 111

NRA 111

C Vid/S Vid Rewrite NR NRA Instances reset

NRA Instances reset

NRA Instances reset

NRA Instances reset

NRA Instances reset

Port Based VLan tab

LAN1 NR NR NRA Enable

NRA Enable

NRA Enable

NRA Enable

LAN2 DisableRO

NRA Enable

DisableRO

NRA Enable

NRA Enable

NRA Enable

Priority Management tab

All NR NR NR NR NR NR

Page 120: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

118 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

If the analysis of the priority at level 2 is active and prioritary, a packet in input from any Ethernet port ofthe equipment, with a valid Tag value of priority 802.1p, will be automatically assigned to one of the fourqueues of the output port, according to what pointed out in the table 802.1p Priority Management.

If the analysis of the priority at level 3 is active and prioritary, the field PTOS/DSCP present in the headingof the IP packets (values 0÷63) will be considered.

The priority standard can be modified by the user and is common to all the Ethernet ports.

MAC Table

The MAC Table is a table created by the Ethernet Switch to keep trace of the reachability of the equipmentpresent in the network.For the editing of the MAC Table, the Switch uses the MAC address (source) of the packets in input and thenumber of the port through which a packet enters in the Switch as information source.The source MAC of a packet in input to the Switch is subjected to Learning operation and possibly registeredin MAC Table.The destination MAC of a packet in input to the Switch is subjected to search operation. If it is found inMAC Table as source MAC of another user, the port associated to it is used as destination of the consideredtraffic.If the destination MAC Address is not present in the MAC Table, the Switch transmits the frame on all itsown interfaces, excluding only that where the frame itself has been received.A MAC address stored in the table is automatically deleted from the table itself if not used within a giventime period (Aging Time).

The address learning in MAC Table is usually automatic.ALFOplus80 equipment allow enabling/disabling the learning of Source MAC Addresses according to differ-ent criteria select able by the user:

1.Automatic learning on a single MAC Table.2.Automatic learning on different MAC Tables indicized by:

a. Native VID of a VLAN 802.1Q, if the input port is in Fallback or Secure and the considered VLANis registered in VLAN Table Unit (VTU).

b. Port default VID, if the incoming traffic is Untagged or, if tagged, the option 802.1Q is disabledon the considered port or if the native VID of the incoming traffic is NOT registered in VTU. Inpractice, in this condition the partition of MAC Table is made on port basis.

3.Learning disabled; in this condition MAC Table is not used.

The learning on VID basis is common to all the ports and the option is select able at global level.The learning on port basis can be selected independently for every different LAN.The automatic learning on a single MAC Table and the possible disabling of Learning can be selected on thesingle LANs (LAN) and internal port (Radio).If options a. and b. are selected at the same time, option a. has priority.

By means of the application, it is possible:• Delete the content of the MAC Table on the equipment.• Define the validity period of the addresses stored in the MAC Table of the equipment (parameter

MAC Addr. Aging Time).• Define if the learning of the Source Addresses must be made on a common MAC Table or on

specific partitions for every single VID registered in VLAN Table Unit (VTU) (parameter MACLearning Vid basis).

• Enable/disable the automatic learning of MAC Address within the VTU for every single port ofthe Ethernet Switch and, if enabled, to define if this learning must be made on a single MACTable common to the whole Switch or on a partition specific for the port (parameter MAC Learn-ing).

Page 121: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 119

LAN 1, LAN 2

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Setting a management configuration introduces some restrictions on the setting of the EthernetSwitch parameters (see Management configurations (info), Tab.4 and Tab.5).

The LAN 1 e LAN 2 commands manage the Ethernet external ports. When one of two commands is selected, the LAN <number relevant to the selected Lan> contextual areaopens, where the specific LAN can be managed.In detail, the command allows:

STATUS AND COMMUNICATION PARAMETERS

Verify/modify the enabling status of the LANVerify/modify the inversion status of the Tx and Rx lines of the LANVerify/modify the enabling status of the auto negotiation and, if the auto negotiation is inactive, theoperation modality and the transmission speed used by the LANVerify/modify the enabling status of the flow control of the LANVerify/modify the automatic learning of the addresses in MAC Table for the LANRestart the auto negotiation procedure for the LANVerify/modify the operating modality of the line synchronism (role) for the LANVerify/modify the activation status of the autonegotiation between the roles of the line synchronism forthe LAN

VIRTUAL LAN PARAMETERS Verify/modify the default VID value of the LANVerify/modify the management of 802.1Q field on the messages in input from the LANVerify/modify the traffic transport modality (point-point or Bridge)Verify/modify the management of Provider Tag in the packets in input from the LANVerify/overwrite the C-VID value of the packets in input from the LAN and forwarded to the Radio witha different VIDVerify the list of VIDs registered in VLAN Table Unit and associated to the LANVerify/modify the management of the LAN in Provider modeVerify/modify the ports through which the messages in input from the LAN can transit

PRIORITY PARAMETERS Verify/modify the priority criterion used to associate the packets in input from the LAN to the outputqueueVerify/modify the value of default priority 802.1pVerify/remap the priority (802.1p) inside the Tag VLan of the LAN

LLF PARAMETERS

Verify/modify the enabling status of Link Loss Forwarding modality of the LAN

LOOP

Activate/deactivate the loop on line side of the LAN

LASER PARAMETERS

Verify the status and the configuration of the laser (LAN)Modify the enabling status of the laser (LAN)Modify the transmission mode of the laser (LAN)Enable manually the laser transmission (LAN)Execute the test laser operating status (LAN)

The selection of the command displays the LAN 1, LAN 2 contextual area.

Page 122: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

120 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the enabling status of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.The Rate Control parameter indicates the enabling status of the port:

• Disable. The LAN is not enabled to the use.• Full Rate. The LAN is enabled to the use of the maximum bit rate relevant to the port. • ...Kb/...Mb. The LAN is enabled to the use with bit rate limited to the specific value.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the inversion status of the Tx and Rx lines of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only for ports with electrical interface for which the use ofthe LAN is enabled (see Verify/modify the enabling status of the LAN).

1. Select Base Band > LAN 1 or LAN 2.The Cable Crossover parameter indicates the inversion status of the Tx and Rx lines:

• MDI (NIC). The inversion of the Tx and Rx lines is not active (Network Interface Card modality).• MDIX (switch). The inversion of the Tx and Rx lines is active (Switch modality).• Auto. The inversion of the Tx and Rx lines is active in automatic modality.

2. To change the parameter, select the wished option

3. Press Apply and confirm.

Verify/modify the enabling status of the auto negotiation and, if the auto negotiation is inactive, the operation modality and the transmission speed used by the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.The Speed/Duplex parameter indicates the enabling status of the auto negotiation and, if the auto ne-gotiation is inactive, the operation modality and the transmission speed used by the LAN.For LAN 1 and LAN 2 with electrical interface, the following values are available:

• Full-Duplex-10M. The auto negotiation is disabled, the transmission type is Full-Duplex and thedata transmission speed through the LAN is 10Mbit/s.

• Half-Duplex-10M. The auto negotiation is disabled, the transmission type is Half-Duplex and thedata transmission speed through the LAN is 10Mbit/s.

• Full-Duplex-100M. The auto negotiation is disabled, the transmission type is Full-Duplex and thedata transmission speed through the LAN is 100Mbit/s.

• Half-Duplex-100M. The auto negotiation is disabled, the transmission type is Half-Duplex andthe data transmission speed through the LAN is 100Mbit/s.

• Auto. The auto negotiation is enabled.For LAN 1 with optical interface, the following values are available:

• Full-Duplex-100M. The auto negotiation is disabled, the transmission type is Full-Duplex and thedata transmission speed through the LAN is 100Mbit/s.

• Full-Duplex-1G. The auto negotiation is disabled, the transmission type is Full-Duplex and thedata transmission speed through the LAN is 1GMbit/s.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Page 123: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 121

Verify/modify the enabling status of the flow control of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.The Flow Control Full Dplx/Back Pressure Half Dplx parameter indicates the activation status of the flowcontrol of the LAN:

• Disable. The flow control is forced inactive.• Enable. The flow control is forced active.• Auto. The flow control is automatic (automatically activated or deactivated by the auto negoti-

ation procedure). Option available only if the auto negotiation is active for the port (Speed/Duplex box - Auto op-tion).

In Full-Duplex modality, the flow control is regulated according to the 802.3x normative. In Half-Duplexmodality, the flow control is regulated according to the Back Pressure technique.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the automatic learning of the addresses in MAC Table for the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The MAC-based routing functionality in the Ethernet Switch is available only if enabled this func-tion.

1. Select Base Band > LAN 1 or LAN 2.The MAC Learning parameter indicates the enabling status of the automatic learning of the MAC Ad-dress in the specific table (MAC Table):

• Disable. The automatic learning of the MAC Address is disabled.• Enable. The automatic learning of MAC Address is enabled. Learning of the addresses in the table

takes place analysing only the field MAC Address and is registered in a single MAC Table.• Learn. on port basis. The automatic learning of MAC Address is enabled. Learning of the address-

es in the table takes place associating the MAC Address to the segment of MAC Table indicizedby the Default VID value associated to the port which the traffic is income from.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Restart the auto negotiation procedure for the LAN

User Profile | Station Operator, System

WARNING Operation available only if the auto negotiation is enabled (Speed/Duplex and/or Flow Control...box - Auto option).

1. Select Base Band > LAN 1 or LAN 2.

2. Press Restart Autonegotiation and confirm.

Page 124: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

122 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the operating modality of the line synchronism (role) for the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only for ports with electrical interface for which the auton-egotiation is active and the 1000Base-T configuration is active (see Verify/modify the enabling status ofthe auto negotiation and, if the auto negotiation is inactive, the operation modality and the transmissionspeed used by the LAN).

1. Select Base Band > LAN 1 or LAN 2.The Master/Slave parameter indicates the operating modality of the line synchronism (role) of the LAN:

• Master. The line synchronism is generated starting from the local clock.• Slave. The line synchronism is generated with the clock retrieved from the line (Loop Time).

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the activation status of the autonegotiation between the roles of the line synchronism for the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only for ports with electrical interface for which the auton-egotiation is active and the 1000Base-T configuration is active (see Verify/modify the enabling status ofthe auto negotiation and, if the auto negotiation is inactive, the operation modality and the transmissionspeed used by the LAN).

1. Select Base Band > LAN 1 or LAN 2.The M/S Autoneg. parameter indicates the activation status of the autonegotiation between the rolesof the line synchronism of the LAN:

• Enable. The autonegotiation between the roles Master and Slave of the line synchronism is au-tomatic.

• Disable. The autonegotiation between the roles Master and Slave of the line synchronism isforced. In this case, the role defined in the Master/Slave box is used.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the default VID value of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The Default Vid parameter indicates the default VLAN Identifier value of the port.The default VID of a port is used a S-VID in the field 802.1Q of the packets came from the port in sub-ject without Tag and destined to exit with Tag from any port of the Switch.

3. To change the parameter, type a numeric value between 2 and 4094.

4. Press Apply and confirm.

Page 125: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 123

Verify/modify the management of 802.1Q field on the messages in input from the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The 802.1q Settings parameter indicates the management of the 802.1Q field on the messages in inputfrom the LAN:

• Disabled. The LAN does not analyse the Tag (802.1Q) of the packets in input. They will be sentonly to the ports indicated in the Port Based VLAN area.

• Fallback. Packets are not discarded if the VLAN, which the packets belong to, is not registeredin VLAN Table Unit (VTU).If VID (VLAN Identifier) of incoming packet is registered in VTU, it can be forwarded only on theports belonging to the VLANs registered in VTU and included in VLAN on port basis.If VID of incoming packet is NOT registered in VTU, it can be forwarded only on the ports includ-ed in VLAN on port basis.

• Secure. VID must be contained in VTU and the input pot must be member of this VLAN, other-wise the packet is discarded.A packet can exit from the ports belonging to the VLAN registered in VTU and are included inVLAN on port basis.

For each configuration (selection of the Disabled, Fallback or Secure option) the table of Port BasedVLAN must be ALWAYS configured even if the traffic management is executed only on Tag base (seeVerify/modify the ports through which the messages in input from the LAN can transit). If you wish to obtain a bidirectional traffic routed according the Vlan table, the control of the Tag 802.1Q(Fallback or Secure) must be activated on all the ports.

3. To change the parameter, select the wished option.

4. Press Apply and confirm.If the user sets a parameter value not allowed by the equipment, the system displays the Commandrejected: incompatible equipment status message.

Verify/modify the traffic transport modality (point-point or Bridge)

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the parameter 802.1q Settings has value Disabled orFallback.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The Traffic Treatment parameter indicates the traffic transport modality (point-point or Bridge):

• Transparent Port to Port Transport. The traffic entering from a local LAN will automatically exitonly from the equivalent remote LAN, unless the single VLANs registered in VLAN Table Unit(VTU) and routed by the user in different mode.

• Transparent Bridge Port Based. The traffic entering from a local LAN will automatically exit fromall the remote LANs enabled by VLAN per port, unless the single VLANs registered in VTU androuted by the user in different mode.

3. To change the parameter, select the wished option.

4. Press Apply and confirm.If the user sets a parameter value not allowed by the equipment, the system displays the Commandrejected: incompatible equipment status message.

Page 126: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

124 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the management of Provider Tag in the packets in input from the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the parameter 802.1q Settings has value Fallback.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The parameter Selective Provider Tag indicates the insertion modality of Provider Tag in the packets ininput from the LAN in selective mode and not on port basis:

• Disable. Option disabled: the Provider Tag is not inserted in the packets in selective mode.• C_Vid Based. Option enabled: the Provider Tag is inserted in the packets according to C-VID

(Customer VLAN Identifier) value.• C_Vid + Internal Priority. Option enabled: the Provider Tag is inserted in the packets according

to C-VID (Customer VLAN Identifier) value and Internal Priority value.

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Verify/overwrite the C-VID value of the packets in input from the LAN and forwarded to the Radio with a different VID

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the parameter 802.1q Settings has value Fallback.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The table Lan to Radio C_Vid Rewrite... indicates the correspondence between the C-VID value of thepackets in input from the LAN and the identifier used to replace C-VID in the packets forwarded to theRadio port.The name and the column of the table change according to the value set for the parameter SelectiveProvider Tag. In detail, if for the parameter Selective Provider Tag the set value is:

• Disable, the tab contains the table Lan to Radio C_Vid Rewrite. In the column:• Input C Vid. Value C-VID (Customer VLAN Identifier) of the packets in input from the LAN

you wish to overwrite.• Output C Vid. New value of C-VID you wish to forward to Radio port.

To add a value to the list press Add. Set the Input C Vid and Output C Vid parameters with thewished value. Press Apply and confirm.To delete a value select the relevant row. Press Remove and confirm.

• C_Vid Based, the tab contains the table Lan to Radio C_Vid Rewrite & Selective QinQ. In thecolumn:

• Input C Vid. C-VID value of the packets in input from the LAN which you wish to addS_TAG.

• Output C Vid. New value of C-VID you wish to forward to Radio port. This value can beequal to or different from the native C-VID incoming from LANs.

• Output S VID. New value of S-TAG added to the set C-VID value.To add a value to the list press Add. Set the Input C Vid, Output C Vid and Output S VID pa-rameters with the wished value. Press Apply and confirm.To delete a value select the relevant row. Press Remove and confirm.

• C_Vid + Internal Priority, the tab contains the table Lan to Radio C_Vid Rewrite & Selective QinQ.In the column:

• Input C Vid. C-VID value of the packets in input from the LAN which you wish to addS_TAG to.

• Internal Priority. Value of priority associated to the packets incoming from the consideredLAN with the specific C-VID selected, which you wish to add a S-TAG to.

Page 127: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 125

• Output S VID. New value of S-TAG added to set C-VID value and priority.To add a value to the list press Add. Set the Input C Vid, Internal Priority e Output S VID pa-rameters with the wished value. Press Apply and confirm.To delete a value select the relevant row. Press Remove and confirm.

Verify the list of VIDs registered in VLAN Table Unit and associated to the LAN

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Operation available and meaningful only if the parameter 802.1q Settings has value Fallback orSecure.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.

The Port C_Vid table displays the list of C-VIDs (Customer VLAN Identifier) registered in VLAN TableUnit (VTU) and associated to the LAN. In the column:

• C_Vid. C-VID value registered in VTU.• VLan Label. Possible name associated to the registered C-VID value.• Frame Forwarding. Modality used to manage the registered C-VID.

Table available when the parameter 802.1q Settings has value Fallback or Secure (box Provider inac-tive).

The Port S_Vid table displays the list of S-VIDs (Service VLAN Identifier) registered in VTU and associ-ated to the LAN. In the column:

• S_Vid. S-VID value registered in VTU.• VLan Label. Possible name associated to the registered S-VID value.• Frame Forwarding. Modality used to manage the registered S-VID.

Table available when the parameter 802.1q Settings has value Secure (box Provider active).

Verify/modify the management of the LAN in Provider mode

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the parameter 802.1q Settings has value Secure.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the 802.1Q Management tab.The Provider parameter indicates the management of the LAN in Provider Mode.Active box ( ) means that for the LAN the Provider mode (Double Tag active) is set; inactive box in-dicates that for the LAN the Provider mode (Double Tag inactive) is not set.

3. To change the parameter, check or uncheck the relevant box.

4. Press Apply and confirm.

Verify/modify the ports through which the messages in input from the LAN can tran-sit

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the Port Based VLan tab.

Page 128: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

126 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

The Port Based VLAN area indicates the enabling status of the ports through which can transit the mes-sages in input from the LAN:

• Disable, the packets in input from the LAN, are not enabled to transit from the specific internalor LAN.

• Enable, the packets in input from the LAN, are enabled to transit from the specific internal orLAN (bidirectional connection).

The box relevant to the LAN, which the tab refers to, is not displayed.

3. To change the parameter, select the wished option.Enabling a port involves the automatic enabling of the corresponding port. For example, if you enableLAN 1 in the Port A contextual area, the Port A is automatically enabled in the LAN 1 contextual area.

4. Press Apply and confirm.

Verify/modify the priority criterion used to associate the packets in input from the LAN to the output queue

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the Priority Management tab.The Priority Selection parameter indicates the priority criterion used to associated the packets, in inputto the LAN, to the output queue:

• Disable, to disable the priority management.• 802.1P, to analyse the value of priority 802.1p (level 2) for the selection of the output queue.• IpTOS, to analyse the value of TOS (Type Of Service) (level 3).

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Verify/modify the value of default priority 802.1p

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the Priority Management tab.The parameter Default Priority indicates the value to insert in 802.1p field of the packets entering inthe LAN, which the Tag is added to (0: lowest priority, 7: highest priority).

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Verify/remap the priority (802.1p) inside the Tag VLan of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the analysis of the value of the priority 802.1p (pa-rameter Priority Selection set to the Native 802.1p (C_Vid) value) is active.

1. Select Base Band > LAN 1 or LAN 2.

2. Select the Priority Management tab.The tab, if the analysis of the priority 802.1p value is active, displays a table pointing out the mappingof priority 802.1p within Tag VLan (priority 802.1p present into a packet in input to a port can be rem-apped in output from the Switch with a different priority value).

Page 129: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 127

Table rows (802-1p INPUT Priority - 7÷0) correspond to Tag 802.1p value of the packet in input to theSwitch.Table columns (802.1p OUTPUT Priority Remapping - 0÷7) correspond to Tag 802.1p value of the pack-et in output from the Switch.The active option indicates, for every priority of the packet in input to the Switch (802-1p INPUT...),the relevant priority in output from the Switch (802.1p OUTPUT...).

3. In order to change a value, select in the table the option corresponding to the wished combination:values of Tag 802.1p in input to the port - value of Tag 802.1p in output from the Switch.

4. Press Apply and confirm.

Verify/modify the enabling status of Link Loss Forwarding modality of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > LAN 1 or LAN 2.

2. Select the LLF tab.The LLF parameter indicates the enabling status of the Link Loss Forwarding modality:

• Disable. The LLF modality is disabled. • Local. The LLF modality is enabled: the port is disabled in presence of radio alarms (BASE BAND

Link Loss Forwarding Alarm, RADIO Link Id. Alarm) or if the internal port is disabled.Only if the Local option is active, the activation of the check-box:

• Rem. LAN-1, indicates that the port is disabled even in presence of a LOS alarm on the remoteLAN 1 port associated to it.

• Rem. LAN-2, indicates that the port is disabled even in presence of a LOS alarm on the remoteLAN 2 port associated to it.

3. To change the parameter, select the wished options.

4. Press Apply and confirm.

Activate/deactivate the loop on line side of the LAN

User Profile | Read & Write, Station Operator, System

WARNING Operation of maintenance (MAN. OP). The loop activation can compromise the transit of supervision (see Tab.8).

1. Select Base Band > LAN 1 or LAN 2.

2. Select the Line Loop tab.The Line Loop parameter displays the status of the loop on line side of the LAN:

• Enable. Loop on line side active.• Disable. Loop on line side inactive.

3. To change the parameter, select the wished option.

4. Press Apply.Only if you are activating the loop a message warns that you are executing a forcing and displays thecurrent setting of timeout.

5. Confirm the operation. The activation of a loop activates the MAN. OP alarm. If the equipment is switched off and, then,switched on, the loop is inactive, independently from the previous setting.

Page 130: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

128 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify the status and the configuration of the laser (LAN)

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Operation available only for LAN 1 with optical interfaces.

1. Select Base Band > LAN 1.

2. Select the Laser Control tab.The tab displays the current status and the configuration parameters of the laser.

Modify the enabling status of the laser (LAN)

User Profile | Read & Write, Station Operator, System

WARNING Operation available only for LAN 1 with optical interfaces. Operation of maintenance (MAN. OP).

1. Select Base Band > LAN 1.

2. Select the Laser Control tab.In the Transmitter Control area the enabling status of the laser is pointed out:

• On. The laser is enabled for transmission. • Off. The laser is not enabled for transmission.

3. To change the parameter, select the wished option.

4. Press Apply. Only if you are disabling the laser (selection of the Off option), a message warns that you are executinga forcing and displays the current setting of the timeout.

5. Confirm the operation. The laser disabling activates the MAN. OP alarm. If the equipment is switched off and switched off, thelaser is enabled to transmit independently from the previous setting.

Modify the transmission mode of the laser (LAN)

User Profile | Read & Write, Station Operator, System

WARNING Operation available only for LAN 1 with optical interfaces. Operation of maintenance (MAN. OP).

1. Select Base Band > LAN 1.

2. Select the Laser Control tab.The Mode parameter indicates the transmission mode of the laser:

• Disable. The laser transmission is affected only by its enabling status and not by the real pres-ence of the optical signal.

• Auto. The transmission of the laser is affected by the presence of the optical signal: when thesignal is present, the laser transmits, when the signal is not present, the laser does not transmit. In this last condition, the controller automatically turns the laser on for 2 seconds every x sec-onds (value adjustable in Auto Restart Time box) to activate the remote transmitter: if the signalat reception is present, the laser will continue to transmit, otherwise, after x seconds, the laserwill be turned on again for 2 seconds and so on.To change the Auto Restart Time interval set into the relevant box a value between 60 and 300sec. (default 120 sec.). Select the Apply and confirm.

• Manual. The laser transmission is manually enabled by the operator.• Test. The laser transmits for x seconds (operation of laser functioning status).

Page 131: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 129

3. To change the parameter, select the wished option.

4. Press Apply.Only if you are setting Disable, Manual or Test as transmission modality for the laser, a message warnsthat you are executing a forcing and displays the current setting of the timeout.

5. Confirm the operation. The selection of a modality different from Auto activates the MAN. OP alarm. If the user turns off theequipment and then turns it on again, without taking into any account the preceding setting, the trans-mission mode of the laser is Auto.

Enable manually the laser transmission (LAN)

User Profile | Read & Write, Station Operator, System

WARNING Operation available only for LAN 1 with optical interfaces Operation of maintenance (MAN. OP).

1. Select Base Band > LAN 1.

2. Select the Laser Control tab.

3. Select the Manual option.

4. Press Apply.A message warns that you are executing a forcing and shows the current setting of timeout.

5. Confirm the operation. The setting of the Manual modality, activates the MAN. OP alarm.

6. Press Restart and confirm. The laser transmits for 2 seconds and then stops itself.

Execute the test laser operating status (LAN)

User Profile | Read & Write, Station Operator, System

WARNING Operation available only for LAN 1 with optical interfaces. Operation of maintenance (MAN. OP).

1. Select Base Band > LAN 1.

2. Select the Laser Control tab.

3. Set, into the Test Time box, the number of seconds during which the user wants to turn on the laser.To change the time interval set into the box a value between 1 and 100 sec. (default 90 sec.).

4. Select the Test option.

5. Press Apply. A message warns that you are executing a forcing and shows the current setting of timeout.

6. Confirm the operation.The setting of the Test modality, activates the MAN. OP alarm.

7. Press Restart and confirm.The laser transmits for the number of seconds set into the Test Time box and then it stops itself.

Page 132: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

130 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

LAN 1, LAN 2 contextual area

The contextual area contains the:Interface tab. The tab displays the general configuration parameters of the LAN.802.1Q Management tab. The tab displays the configuration parameters of the LAN relevant to VLANmanagement.Port Based VLAN tab. The tab displays the ports through which can transit the messages in input fromthe specific LAN.Priority Management tab. The tab displays the configuration parameters of the LAN relevant to prioritymanagement.LLF tab. The tab displays the enabling status of the Link Loss Forwarding modality.Line Loop tab. The tab displays the status of the loop on line side of the LAN. Laser Control tab. The tab displays the configuration of the LAN with optical interface.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Interface tab

The tab displays the general configuration parameters of the LAN.

Master/Slave. Operating modality of the line synchronism:• Master. The line synchronism is generated starting from the local clock.• Slave. The line synchronism is generated starting from the clock retrieved from the line

(Loop Time).Parameter available and meaningful only for the ports with electrical interface for which the autonego-tiation is active (box Speed/Duplex - value Auto) and the 1000Base-T configuration is active.

M/S Autoneg. Activation status of the autonegotiation between the roles of the line synchronism:• Enable. The autonegotiation between the roles Master and Slave of the line synchronism is

automatic.• Disable. The autonegotiation between the roles Master and Slave of the line synchronism is

forced. In this case, the role defined in the Master/Slave box is used.Parameter available and meaningful only for ports with electrical interface for which the autonegotiationis active (box Speed/Duplex – value Auto) and the 1000Base-T configuration is active.

Rate Control. Enabling status of the port:• Disable. The LAN is not enabled to the use.• Full Rate. The LAN is enabled to the use of the max bit rate relevant to the port. • ...Kb/...Mb. The LAN is enabled to the use with bit rate limited to the specific value.

Flow Control Full Dplx / Back Pressure Half Dplx. Activation status of the flow control of the port:• Disable. The flow control is forced inactive.• Enable. The flow control is forced active.• Auto. The flow control is automatic (automatically activated or deactivated by the auto ne-

gotiation procedure).Option available only if the auto negotiation is active for the port (Speed/Duplex box - Autooption).

Cable Crossover. Inversion status of the Tx and Rx lines:• MDI (NIC). The inversion of the Tx and Rx lines is not active (Network Interface Card mo-

dality).• MDIX (switch). The inversion of the Tx and Rx lines is active (Switch modality).• Auto. The inversion of the Tx and Rx lines is active in automatic modality.

Page 133: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 131

Parameter available and meaningful only for ports with electrical interface for which the use of LAN isenabled (box Rate Control – value Full Rate or ...Kb/...Mb).

Mac Learning. Enabling status of the automatic learning of the MAC Address in the specific table (MACTable):

• Disable. The automatic learning of the MAC Address is disabled.• Enable. The automatic learning of MAC Address is enabled. Learning of the addresses in the

table takes place analysing only the field MAC Address and is registered in a single MAC Ta-ble.

• Learn. on port basis. The automatic learning of MAC Address is enabled. Learning of the ad-dresses in the table takes place associating the MAC Address to the segment of MAC Tableindicized by the Default VID value associated to the port which the traffic is income from.

Speed/Duplex. Activation status of the autonegotiation and, if the autonegotiation is deactivated, op-erating modalities and transmission speed of the port.For LAN 1 and LAN 2 with electrical interface, the following values are available:

• Full-Duplex-10M. The auto negotiation is disabled, the transmission type is Full-Duplex andthe data transmission speed through the LAN is 10Mbit/s.

• Half-Duplex-10M. The auto negotiation is disabled, the transmission type is Half-Duplex andthe data transmission speed through the LAN is 10Mbit/s.

• Full-Duplex-100M. The auto negotiation is disabled, the transmission type is Full-Duplex andthe data transmission speed through the LAN is 100Mbit/s.

• Half-Duplex-100M. The auto negotiation is disabled, the transmission type is Half-Duplexand the data transmission speed through the LAN is 100Mbit/s.

• Auto. The auto negotiation is enabled.For LAN 1 with optical interface, the following values are available:

• Full-Duplex-100M. The auto negotiation is disabled, the transmission type is Full-Duplex andthe data transmission speed through the LAN is 100Mbit/s.

• Full-Duplex-1G. The auto negotiation is disabled, the transmission type is Full-Duplex andthe data transmission speed through the LAN is 1GMbit/s.

Speed. Data transmission speed.

Duplex. Transmission modality.

Port Role. Current status of the line synchronism.Parameter available and meaningful only for ports with electrical interface for which the autonegotiationis active (box Speed/Duplex – value Auto) and the 1000Base-T configuration is active.

Alarms. Status of the alarms relevant to the port. The colour of the boxes represents the alarm statusand severity:

• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-jor, Minor, Warning severity.

• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

Push-button:Restart Autonegotiation. Restart the auto negotiation procedure for the LAN.

Related TopicsVerify/modify the enabling status of the LANVerify/modify the inversion status of the Tx and Rx lines of the LANVerify/modify the enabling status of the auto negotiation and, if the auto negotiation is inactive, theoperation modality and the transmission speed used by the LANVerify/modify the enabling status of the flow control of the LANVerify/modify the automatic learning of the addresses in MAC Table for the LANVerify/modify the operating modality of the line synchronism (role) for the LANVerify/modify the activation status of the autonegotiation between the roles of the line synchronism forthe LAN

Page 134: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

132 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

802.1Q Management tab

The tab displays the configuration parameters of the LAN relevant to VLAN management.

Default Vid. Default VID value of the port.The default VID of a port is used a S-VID in the field 802.1Q of the packets came from the port in sub-ject without Tag and destined to exit with Tag from any port of the Switch.

802.1q Setting. Management of the 802.1Q field on the messages in input from the LAN:• Disabled. The LAN does not analyse the Tag (802.1Q) of the packets in input. They will be

sent only to the ports indicated in the Port Based VLAN area.• Fallback. Packets are not discarded if the VLAN, which the packets belong to, is not regis-

tered in VLAN Table Unit (VTU).If VID of incoming packet is registered in VTU, it can be forwarded only on the ports belong-ing to the VLANs registered in VTU and included in VLAN on port basis.If VID of incoming packet is NOT registered in VTU, it can be forwarded only on the portsincluded in VLAN on port basis.

• Secure. VID must be contained in VTU and the input pot must be member of this VLAN, oth-erwise the packet is discarded.A packet can exit from the ports belonging to the VLAN registered in VTU and are includedin VLAN on port basis.

Traffic Treatment. Traffic transport modality (point-point or Bridge):• Transparent Port to Port Transport. The traffic entering from a local LAN will automatically

exit only from the equivalent remote LAN, unless the single VLANs registered in VTU androuted by the user in different mode.

• Transparent Bridge Port Based. The traffic entering from a local LAN will automatically exitfrom all the remote LANs enabled by VLAN per port, unless the single VLANs registered inVTU and routed by the user in different mode.

Parameter available and meaningful only if the parameter 802.1q Settings has value Disabled or Fall-back.

Selective Provider Tag. Insertion modality of Provider Tag in the packets in input from the LAN inselective mode and not on port basis:

• Disable. Option disabled: the Provider Tag is not inserted in the packets in selective mode.• C_Vid Based. Option enabled: the Provider Tag is inserted in the packets according to C-VID

(Customer VLAN Identifier) value.• C_Vid + Internal Priority. Option enabled: the Provider Tag is inserted in the packets accord-

ing to C-VID (Customer VLAN Identifier) value and Internal Priority value.Parameter available and meaningful only if the parameter 802.1q Settings has value Fallback.

Provider. Active box ( ) means that for the LAN the Provider mode (Double Tag active) is set; inactivebox indicates that for the LAN the Provider mode (Double Tag inactive) is not set.Parameter available and meaningful only if the parameter 802.1q Settings has value Secure.

Lan to Radio C_Vid Rewrite. Table of correspondence between the C-VID value of the packets ininput from the LAN and the identifier used to replace C-VID in the packets forwarded to the Radio port.The column:

• Input C Vid. C-VID (Customer VLAN Identifier) value of the packets in input from the LANyou wish to overwrite.

• Output C Vid. New value of C-VID you wish to forward to Radio port.Push-button:

Add. Add a new value to the list.Remove. Remove a value from the list.

Table available and meaningful only if the parameter 802.1q Settings has value Fallback and the pa-rameter Selective Provider Tag has value Disable.

Lan to Radio C_Vid Rewrite & Selective QinQ. If the parameter Selective Provider Tag has value:• C_Vid Based. Table indicates the correspondence between the C-VID value of the packets in

input from the LAN and the identifier (C-VID and S-VID) used to replace C-VID in the packetsforwarded to the Radio port.The column:

Page 135: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 133

• Input C Vid. C-VID value of the packets in input from the LAN which you wish toadd.

• Output C Vid. New value of C-VID you wish to forward to Radio port. This valuecan be equal to or different from the native C-VID incoming from LANs.

• Output S VID. New value of S-TAG added to the set C-VID value.

• C_Vid + Internal Priority. Table indicates the correspondence between the C-VID value andpriority 802.1p of the packets in input from the LAN and the S-TAG value added to the pack-ets forwarded to the Radio port.The column:

• Input C Vid. C-VID value of the packets in input from the LAN which you wish toadd S_TAG to.

• Internal Priority. Value of priority associated to the packets incoming from theconsidered LAN with the specific C-VID selected, which you wish to add a S-TAGto.

• Output S VID. New value of S-TAG added to set C-VID value and priority.Push-button:

Add. Add a new value to the list.Remove. Remove a value from the list.

Table available and meaningful only if the parameter 802.1q Settings has value Fallback and the pa-rameter Selective Provider Tag has value C_Vid Based or C_Vid + Internal Priority.

Port C_Vid. The table displays the list of C-VID’s (Customer VLAN Identifier) registered in VLAN TableUnit (VTU) and associated to the LAN. In the column:

• C_Vid. C-VID value registered in VTU.• VLan Label. Possible name associated to the registered C-VID value.• Frame Forwarding. Modality used to manage the registered C-VID.

Push-button:Show Table. Display the list of C-VID’s.

Table available when the parameter 802.1q Settings has value Fallback or Secure (parameter Providerdisabled).

Port S_Vid. The table displays the list of S-VID’s (Service VLAN Identifier) registered in VTU and as-sociated to the LAN. In the column:

• S_Vid. S-VID value registered in VTU.• VLan Label. Possible name associated to the registered S-VID value.• Frame Forwarding. Modality used to manage the registered S-VID.

Push-button:Show Table. Display the list of S-VID’s.

Table available when the parameter 802.1q Settings has value Secure (parameter Provider enabled).

Related TopicsVerify/modify the default VID value of the LANVerify/modify the management of 802.1Q field on the messages in input from the LANVerify/modify the traffic transport modality (point-point or Bridge)Verify/modify the management of Provider Tag in the packets in input from the LANVerify/overwrite the C-VID value of the packets in input from the LAN and forwarded to the Radio witha different VIDVerify the list of VIDs registered in VLAN Table Unit and associated to the LANVerify/modify the management of the LAN in Provider mode

Port Based VLAN tab

The tab displays the ports through which can transit the messages in input from the specific LAN.

LAN.../Port A. For each Ethernet port, if the set option is:

Page 136: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

134 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Disable, the packets in input from the LAN, are not enabled to transit through the specificinternal or external port.

• Enable, the packets in input from the LAN, are enabled to transit through the specific internalor external port (bidirectional connection).

The box relevant to the LAN, which the tab refers to, is not displayed.

Related TopicsVerify/modify the ports through which the messages in input from the LAN can transit

Priority Management tab

The tab displays configuration parameters of the LAN relevant to the priority management.

Priority Selection. Priority criterion used to associated the packets, in input to the port, to the outputqueue:If the parameter Current 802.1Q Settings has value:

• Disable, to disable the priority management.• 802.1P, to analyse the value of priority 802.1p (level 2) for the selection of the output queue.• IpTOS, to analyse the value of TOS (Type Of Service) (level 3).

Default Priority. Value used to define the output queue when the selected priority criteria is Disabled(see parameter Priority Selection) and value used as priority 802.1p added to the untagged packetsentering in the considered LAN and they will exit tagged from the corresponding remote LAN:

• 0. Lowest priority • 7. Highest priority.

The tab, if the analysis of the priority 802.1p value is active (parameter Priority Selection set to the Native802.1p (C_Vid) value), displays a table pointing out the mapping of priority 802.1p within Tag VLan (pri-ority 802.1p present into a packet in input to a port can be remapped in output from the Switch with adifferent priority value).Table rows (802-1p INPUT Priority - 7÷0) correspond to Tag 802.1p value of the packet in output from theSwitch.Table columns (802.1p OUTPUT Priority Remapping - 0÷7) correspond to Tag 802.1p value of the packetin output from the Switch.The active option indicates, for every priority of the packet in input to the Switch (802-1p INPUT...), therelevant priority in output from the Switch (802.1p OUTPUT...).

Related TopicsVerify/modify the priority criterion used to associate the packets in input from the LAN to the outputqueueVerify/modify the value of default priority 802.1pVerify/remap the priority (802.1p) inside the Tag VLan of the LAN

LLF tab

The tab displays the enabling status of the Link Loss Forwarding modality.

LLF. Enabling status of the LLF modality:• Disable. The LLF modality is disabled. • Local. The LLF modality is enabled: the port is disabled in presence of radio alarms or if the

internal port is disabled.

Only if the Local option is active, the activation of the check-box: • Rem. LAN-1, indicates that the port is disabled even in presence of a LOS alarm on the re-

mote LAN 1 port associated to it.

Page 137: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 135

• Rem. LAN-2, indicates that the port is disabled even in presence of a LOS alarm on the re-mote LAN 2 port associated to it.

Related TopicsVerify/modify the enabling status of Link Loss Forwarding modality of the LAN

Line Loop tab

The tab displays the status of the loop on line side of the LAN.

Line Loop. Status of the loop on line side of the LAN:• Enable. Loop on line side active.• Disable. Loop on line side inactive.

Related TopicsActivate/deactivate the loop on line side of the LAN

Laser Control tab

WARNING Tab available only for LAN 1 whit optical interface.

The tab displays the configuration of the LAN with optical interface.

Transmitter Control. Enabling status of the laser:• On. The laser is enabled for transmission. • Off. The laser is not enabled for transmission.

<Box>. Current status of the laser:• Status On / green box. The laser is on transmission.• Status Off / gray box. The laser is not on transmission.

Module Type. Laser module type: • optical-100baseFX. Laser module of type 100 Base FX (Fiber). • optical-1000baseSX. Laser module of type 1000 Base SX (Short WaveLength).• optical-1000baseLX. Laser module of type 1000 Base LX (Long WaveLength). • Unknown. The laser module is not among those listed above (possible anomaly of the laser

module).For more information relevant to laser module refer to IEEE standard 802.3.

Mode. Transmission mode of the laser. If active, the option: • Disable. The laser transmission is affected only by its enabling status and not by the real

presence of the optical signal. • Auto. The transmission of the laser is affected by the presence of the optical signal: when

the signal is present, the laser transmits, when the signal is not present, the laser does nottransmit. In this last condition, the controller automatically turns the laser on for 2 seconds every xseconds (value adjustable in Auto Restart Time box) to activate the remote transmitter: ifthe signal at reception is present, the laser will continue to transmit, otherwise after x sec-onds the laser will be turned on again for 2 seconds and so on.

• Manual. The laser transmission is manually enabled by the operator.• Test. The laser transmits for x seconds (operation of test laser operation status).

Auto Restart Time. Time (expressed by means of seconds) waited by the equipment controller beforetrying again the laser turning-on (when the transmission mode of the laser is Auto).

Test Time. Time (expressed in seconds) during which the equipment controller turns on the laser dur-ing the testing operation.

Page 138: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

136 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Push-button:Restart. Restart the laser.

Related TopicsModify the enabling status of the laser (LAN)Modify the transmission mode of the laser (LAN)Enable manually the laser transmission (LAN)Execute the test laser operating status (LAN)

Page 139: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 137

Port A

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Setting a specific management configuration introduces some restrictions on the setting of theEthernet Switch parameters (see Management configurations (info), Tab.6).

The Port A command manages the Ethernet internal port. In detail, the command allows:

STATUS AND COMMUNICATION PARAMETERS

Verify/modify the enabling status of the internal portVerify/modify the enabling status of the flow control of the internal portVerify/modify the automatic learning of the addresses in the MAC Table for the internal port

VIRTUAL LAN PARAMETERS

Verify/modify the control of Tag Vlan Id on the messages in input from the internal portVerify/modify the default VID value of the internal portVerify/overwrite the C-VID value of the packets in input from the internal port and forwarded to a LAN,with a different C-VIDVerify/modify the ports through which the messages in input from the internal port

PRIORITY PARAMETERS

Verify/modify the priority criterion used to associate the packets in input from the internal port to theoutput queue of the LANVerify/modify the default value of priorityVerify/modify the mapping of the priority (802.1p) inside the Tag VLan of the internal port

The selection of the command displays the Port A contextual area

Verify/modify the enabling status of the internal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.The Port parameter indicates the enabling status of the internal port:

• Disable. The internal port is not enabled to the use.• Enable. The internal port is enabled to the use.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the enabling status of the flow control of the internal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.The Flow Control parameter indicates the activation status of the flow control of the internal port:

• Disable. The flow control is forced inactive.• Enable. The flow control is forced active.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Page 140: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

138 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the automatic learning of the addresses in the MAC Table for the inter-nal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING The MAC-based routing functionality in the Ethernet Switch is available only if enabled this func-tion.

1. Select Base Band > Port A.The MAC Learning parameter indicates the enabling status of the automatic learning of the MAC Ad-dress in the specific table (MAC Table):

• Disable. The automatic learning of the MAC Address is disabled.• Enable. The automatic learning of MAC Address is enabled. Learning of the addresses in the table

takes place analysing only the field MAC Address and is registered in a single MAC Table.• Learn. on port basis. The automatic learning of MAC Address is enabled. Learning of the address-

es in the table takes place associating the MAC Address to the segment of MAC Table indicizedby the Default VID value associated to the port which the traffic is income from.

2. To change the parameter, select the wished option.

3. Press Apply and confirm.

Verify/modify the control of Tag Vlan Id on the messages in input from the internal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING In ALFOplus80 equipment, the option Fallback set for the internal port (Radio port) automaticallyinserts, in every packets in output from the Radio port, a proprietary Tag which identifies the source LAN,so that all the advanced operation foreseen for ALFOplus80 can be executed in selective mode. The considered Tag will be automatically removed by the corresponding remote Radio port. The proprietaryTag which identifies the LAN is not inserted if the modality Secure is set, because the traffic source is im-plicitly known observing the VLANs enabled in VTU Table.

1. Select Base Band > Port A.

2. Select the 802.1q Management tab.The Ingress Filtering Check parameter indicates, if active, the control of Tag Vlan Id on the messagesin input from the port:

• Fallback (Provider Enable). Packets are not discarded if the VLAN, which the packets belong to,is not registered in VLAN Table Unit (VTU).If VID of incoming packet is registered in VTU, it can be forwarded only on the ports belongingto the VLANs registered in VTU and included in VLAN on port basis.If VID of incoming packet is NOT registered in VTU, it can be forwarded only on the ports includ-ed in VLAN on port basis.

• Secure (Provider Disable). VID must be contained in VLAN Table Unit (VTU) and the input potmust be member of this VLAN, otherwise the packet is discarded.A packet can exit from the ports belonging to the VLAN registered in VTU and are included inVLAN on port basis.

For each configuration (selection of the value Fallback and Secure) the table of Port Based VLAN mustbe ALWAYS configured even if the traffic management is executed only on Tag base (see Verify/modifythe ports through which the messages in input from the internal port).If you wish to obtain a bidirectional traffic routed according the Vlan table, the control of the Tag 802.1Q(Fallback or Secure) must be activated on all the ports.

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Page 141: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 139

Verify/modify the default VID value of the internal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.

2. Select the 802.1q Management tab.The Default Vid parameter indicates the default VID value of the port.The default VID of a port is used a Sa S-VID in the field 802.1Q of the packets came from the port insubject without Tag and destined to exit with Tag from any port of the Switch.

3. To change the parameter, type a numeric value between 2 and 4094.

4. Press Apply and confirm.

Verify/overwrite the C-VID value of the packets in input from the internal port and forwarded to a LAN, with a different C-VID

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.

2. Select the 802.1q Management tab.The table C Vid/S Vid Rewrite indicates the correspondence between the C-VID value of the packets ininput from the internal port and the identifier used to replace C-VID in the packets forwarded to a LAN.Every row of the table corresponds to a rule for which is pointed out in the column:

• Input C Vid. Identifier C-VID (Customer VLAN Identifier) you wish to overwrite.• Output C Vid. New value of C-VID you wish to forward to LAN.• Output Lan (S Vid). LAN which you wish to forward the new C-VID to.

3. To add an element to the list:

a. Press Add.

b. Set the Input C Vid, Output C Vid and Output Lan filed as described above.

c. Press Apply and confirm.

4. To delete an element from the list:

a. Select the element.Multiple selections can be executed using the Ctrl or Shift keys.

b. Press Remove and confirm.

Verify/modify the ports through which the messages in input from the internal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.

2. Select the Port Based VLan tab.The Port Based VLAN area indicates the enabling status of the LANs through which can transit the mes-sages in input from the internal port:

• Disable, the packets in input from the internal port are not enabled to transit from the specificLAN.

• Enable, the packets in input from the internal port are enabled to transit from the specific LAN(bidirectional connection).

3. To change the parameter, select the wished option.Enabling a port involves the automatic enabling of the corresponding port. For example, if you enableLAN 1 in the Port A contextual area, the Port A is automatically enabled in the LAN 1 contextual area.

4. Press Apply and confirm.

Page 142: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

140 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the priority criterion used to associate the packets in input from the internal port to the output queue of the LAN

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.

2. Select the Priority Management tab.The Priority Selection parameter indicates the priority criterion used to associated the packets, in inputto the internal port, to the output of the LAN:

• Port Default. The traffic will be sent to the output queues of the LANs according to the defaultvalue set by the user on the Radio port.

• Native 802.1P. The traffic will be sent to the output queues of the LANs according to the valueof native 802.1p priority in input to Radio port.

• Native TOS/DSCP. The traffic will be sent to the output queues of the LANs according to the TOS/DSCP value present in the native IP field in input to Radio port.

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Verify/modify the default value of priority

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Base Band > Port A.

2. Select the Priority Management tab.The Default Priority parameter indicates the value used to define the output queue of the LANs whenthe selected priority criteria is Disabled (see parameter Priority) (0: lowest priority, 7: highest priority).

3. To change the parameter, select the wished value.

4. Press Apply and confirm.

Verify/modify the mapping of the priority (802.1p) inside the Tag VLan of the inter-nal port

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available and meaningful only if the analysis of the value of the priority 802.1p (pa-rameter Priority Selection set to the value 802.1P) is active.

1. Select Base Band > Port A.

2. Select the Priority Management tab.The tab, if the analysis of the priority 802.1p value is active, displays a table pointing out the mappingof priority 802.1p within Tag VLan (priority 802.1p present into a packet in input to a port can be rem-apped in output from the Switch with a different priority value).Table rows (802-1p INPUT Priority - 7÷0) correspond to Tag 802.1p value of the packet in input to theSwitch.Table columns (802.1p OUTPUT Priority Remapping - 0÷7) correspond to Tag 802.1p value of the pack-et in output from the Switch.The active option indicates, for every priority of the packet in input to the Switch (802-1p INPUT...),the relevant priority in output from the Switch (802.1p OUTPUT...).

3. In order to change a value, select in the table the option corresponding to the wished combination:values of Tag 802.1p in input to the port - value of Tag 802.1p in output from the Switch.

4. Press Apply and confirm.

Page 143: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 141

Port A contextual area

The contextual area contains the:Interface tab. The tab displays the general configuration parameters of the internal port.802.1q Management tab. The tab displays the configuration parameters of the internal port relevant toVLAN management.Port Based VLan tab. The tab displays the ports through which can transit the messages in input fromthe internal port.Priority Management tab. The tab displays the configuration parameters of the internal port relevant topriority management.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Interface tab

The tab displays the general configuration parameters of the internal port.

Port. Enabling status of the port:• Disable. The internal port is not enabled to the use.• Enable. The internal port is enabled.

Flow Control. Activation status of the flow control of the internal port: • Disable. The flow control is forced inactive.• Enable. The flow control is forced active.

Mac Learning. Enabling status of the automatic learning of the MAC Address in the specific table (MACTable):

• Disable. The automatic learning of the MAC Address is disabled.• Enable. The automatic learning of MAC Address is enabled. Learning of the addresses in the

table takes place analysing only the field MAC Address and is registered in a single MAC Ta-ble.

• Learn. on port basis. The automatic learning of MAC Address is enabled. Learning of the ad-dresses in the table takes place associating the MAC Address to the segment of MAC Tableindicized by the Default VID value associated to the port which the traffic is income from.

Related TopicsVerify/modify the enabling status of the internal portVerify/modify the enabling status of the flow control of the internal portVerify/modify the automatic learning of the addresses in the MAC Table for the internal port

802.1q Management tab

The tab displays the configuration parameters of the internal port relevant to VLAN management.

Ingress Filtering Check. Control status of Tag Vlan ID on the messages in input from the port:• Fallback (Provider Enable). Packets are not discarded if the VLAN, which the packets belong

to, is not registered in VLAN Table Unit (VTU).If VID of incoming packet is registered in VTU, it can be forwarded only on the ports belong-ing to the VLANs registered in VTU and included in VLAN on port basis.If VID of incoming packet is NOT registered in VTU, it can be forwarded only on the portsincluded in VLAN on port basis.

Page 144: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

142 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Secure (Provider Disable). VID must be contained in VLAN Table Unit (VTU) and the inputpot must be member of this VLAN, otherwise the packet is discarded.A packet can exit from the ports belonging to the VLAN registered in VTU and are includedin VLAN on port basis.

• Disable.

Default Vid. Default VID value of the port.The default VID of a port is used a S-VID in the field 802.1Q of the packets came from the port in sub-ject without Tag and destined to exit with Tag from any port of the Switch.

C Vid/S Vid Rewrite. Table of correspondence between the C-VID value of the packets in input fromthe internal port and the identifier used to replace C-VID in the packets forwarded to a LAN.Every row of the table corresponds to a rule for which is pointed out in the column:

• Input C Vid. Identifier C-VID (Customer VLAN Identifier) you wish to overwrite.• Output C Vid. New value of C-VID you wish to forward to LAN.• Output Lan (S Vid). LAN which you wish to forward the new C-VID to.

In the C Vid/S Vid Rewrite table the push-button:Add. Add an element to the table.Remove. Delete an element from the table.

Related TopicsVerify/modify the control of Tag Vlan Id on the messages in input from the internal portVerify/modify the default VID value of the internal portVerify/overwrite the C-VID value of the packets in input from the internal port and forwarded to a LAN,with a different C-VID

Port Based VLan tab

The tab displays the ports through which can transit the messages in input from the internal port.

LAN... For each LAN, if the set option is:• Disable, the packets in input from the internal port, are not enabled to transit through the

specific LAN. • Enable, the packets in input from the internal port, are enabled to transit through the specific

LAN (bidirectional connection).

Related TopicsVerify/modify the ports through which the messages in input from the internal port

Priority Management tab

The tab displays the configuration parameters of the LAN relevant to priority management.

Priority Selection. Priority criterion used to associated the packets, in input to the internal port, tothe output of the LANs:

• Disable. The traffic will be sent to the output queues of the LANs according to the defaultvalue set by the user on the Radio port.

• 802.1p. The traffic will be sent to the output queues of the LANs according to the value ofnative 802.1p priority in input to Radio port.

• Ip TOS. The traffic will be sent to the output queues of the LANs according to the TOS/DSCPvalue present in the native IP field in input to Radio port.

Default Priority. Value used to define the output queue of the LANs when the selected priority criteriais Disabled (see parameter Priority Selection):

• 0. Lowest priority

Page 145: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 143

• 7. Highest priority.

The tab, if the analysis of the priority 802.1p value is active (parameter Priority Selection set to value802.1p), displays a table pointing out the mapping of priority 802.1p within Tag VLan (priority 802.1p pre-sent into a packet in input to a port can be remapped in output from the Switch with a different priorityvalue).Table rows (802-1p INPUT Priority - 7÷0) correspond to Tag 802.1p value of the packet in output from theSwitch.Table columns (802.1p OUTPUT Priority Remapping - 0÷7) correspond to Tag 802.1p value of the packetin output from the Switch.The active option indicates, for every priority of the packet in input to the Switch (802-1p INPUT...), therelevant priority in output from the Switch (802.1p OUTPUT...).

Related TopicsVerify/modify the priority criterion used to associate the packets in input from the internal port to theoutput queue of the LANVerify/modify the default value of priorityVerify/modify the mapping of the priority (802.1p) inside the Tag VLan of the internal port

Page 146: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

144 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

RADIO BRANCH

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Radio Branch command manages the radio parameters.In detail, the command allows:

Verify/modify the duplex frequency (Dplx Freq) Verify/modify the frequency which the equipment transmitter is tuned on (Tx Freq)Verify/modify the modulation status of the RF carrier (Carrier Only) Verify/modify the operation of the transmitter (Tx Transmitter) Verify/modify the resolution of the received power (Prx) (Measurements Resolutions) Verify/modify the resolution of the transmitted power (Ptx) (Measurements Resolutions) Verify/modify ATPC operating status (Tx Power Control) Verify/modify the maximum output power value at the transmitter (Max Ptx) Verify/modify the ATPC regulation range (ATPC Regulation) Verify/modify the thresholds of ATPC device (ATPC Thresholds on Local PRx)

The selection of the command displays the Radio Branch contextual area.

Verify/modify the duplex frequency

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation not available for the 17Ghz radio.

1. Select Radio Branch.The Dplx Freq parameter indicates the duplex frequency (MHz) of the equipped radio.The displayed value is always positive, independently from the position of the transmission frequencywith respect to the receiving frequency.

2. To change the parameter, select the wished value.

3. Press Apply and confirm.

Verify/modify the frequency which the equipment transmitter is tuned on

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Setting the parameter does NOT automatically modify even the RF frequency of remote equip-ment.Before setting the transmission frequency of the equipment, set the duplex frequency value.

1. Select Radio Branch.The Tx Freq parameter indicates the transmission frequency of the equipment.

2. To change the parameter, it is possible to:• Set in the Tx Freq box the wished frequency value using the fine tuning step (typically 250 KHz).• Press Freq. Table to display the table of the preferential frequencies (channelling file). Select

the wished value and press Ok. If this value was not present in the table, the radio can be how-ever tuned with fine tuning.Push-button available only if the channelling file has been previously loaded on the equipment.In case of fine-step file (less than 1 MHz), the frequency table does not contain any value toavoid reading not meaningful values.

3. Press Apply and confirm.

Page 147: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 145

Verify/modify the modulation status of the RF carrier

User Profile | Verify: Monitor, Read Only. Modify: Read & Write, Station Operator, System

WARNING Deactivating the modulation is a maintenance operation (MAN. OP).Before deactivating the modulation, configure the transmitter power to the minimum value.

1. Select Radio Branch.The Carrier Only parameter indicates the modulation status of the RF carrier:

• On. The carrier is not modulated. • Off. The carrier is modulated.

2. To change the parameter, select the wished option.

3. Press Apply.Only if you are deactivating the modulation (selection of the On option) a message warns that you areexecuting a forcing and displays the current setting of timeout.

4. Confirm the operation. The modulation deactivation of the carrier activates the MAN. OP alarm. If the equipment is switchedoff and, then, switched on, the modulation is active independently from the previous setting.

Verify/modify the operation of the transmitter

User Profile | Verify: Monitor, Read Only. Modify: Read & Write, Station Operator, System

WARNING Switching the transmitter off is a maintenance operation (MAN. OP).The permanent switch-off of the transmitter (option Permanent Off) is NOT a maintenance operation, sothe selection of this value is not subjected to the Timeout of MAN OP and the setting is not lost after acontroller restart.

1. Select Radio Branch.The Tx Transmitter parameter indicates the operation of the transmitter:

• On. The transmitter is turned on.• Off. The transmitter is turned off.• Permanent Off. The transmitter is turned off in permanent mode.

2. To change the parameter, select the wished option.

3. Press Apply.Only if you are switching off the transmitter (selection of the Off option) a message warns that you areexecuting a forcing and displays the current setting of timeout.

4. Confirm the operation. The turning off of the transmitter activates the MAN. OP alarm. If the equipment is switched off and,then, switched on, the transmitter is on, independently from the previous setting.

Verify/modify the resolution of the received power (Prx)

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Radio Branch.The Prx: <current value> dB parameter indicates the resolution used to communicate the changes ofthe power received by the equipment (Prx) to a possible external management program (trap Prxchange).

2. To change the parameter, move the cursor on the wished value.

3. Press Apply and confirm.

Page 148: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

146 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Verify/modify the resolution of the transmitted power (Ptx)

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Radio Branch.The Ptx: <current value> dB parameter indicates the resolution used to communicate the changes ofthe power transmitted by the equipment (Ptx) to a possible external management program (trap Ptxchange).

2. To change the parameter, move the cursor on the wished value.

3. Press Apply and confirm.

Verify/modify ATPC operating status

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Radio Branch.

2. Select the Powers tab. The Tx Power Control area indicates ATPC operating status:

• Manual. The ATPC device is in manual functioning mode (ATPC function disable). In this condition, it is possible to adjust the maximum output power (Max Ptx cursor).

• Automatic. The ATPC device is in automatic functioning mode. In this condition, the transmitted power is automatically adjusted according to the level of thereceived signal.The thresholds of ATPC device can be configured (see Verify/modify the thresholds of ATPC de-vice). Then, the maximum output power can be adjusted (see Verify/modify the maximum out-put power value at the transmitter).

3. To change the parameter, select the wished option.

4. Press Apply and confirm.

Verify/modify the maximum output power value at the transmitter

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Radio Branch.

2. Select the Powers tab. The Max Ptx: <current value> dB parameter indicates the maximum output power value at the trans-mitter (Ptx nominal value).

3. To change the parameter, move the cursor on the wished value.

4. Press Apply and confirm.

Verify/modify the ATPC regulation range

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

WARNING Operation available only if the ATPC device is in automatic functioning mode (Tx Power Controlparameter - Automatic value).

1. Select Radio Branch.

2. Select the Powers tab.

Page 149: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 147

The ATPC Regulation: <current value> dB parameter indicates the range for the regulation of ATPC(expressed in dB) with respect to the current value of maximum Tx output, that is intended as the upperlimit of the range.

3. To change the parameter, move the cursor on the wished value.

4. Press Apply and confirm.

Verify/modify the thresholds of ATPC device

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Radio Branch.

2. Select the Powers tab. In ATPC Thresholds on Local PRx area, the ATPC thresholds are pointed out:

• High: <current value> dBm. Threshold of ATPC device to decrease the transmitted power whenthe received field from the local equipment is equal to or higher than the set threshold value.

• Low: <current value> dBm. Threshold of ATPC device to increase the transmitted power whenthe received field from the local equipment is equal to or lower than the set threshold value.

3. To change the threshold move the High and/or Low cursor to the wished value.

4. Press Apply and confirm.

Page 150: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

148 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Radio Branch contextual area

In the Radio Branch contextual area is present the:Settings tab. The tab displays the radio parameters (power resolution, transmitter operating status andcarrier modulation). Powers tab. The tab displays the radio parameters (ATPC).

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Settings tab

The tab displays the radio parameters (measurements resolution, transmitter operating status and carriermodulation).

Tx Freq. Frequency of the radio transmission. The wording HW Fail indicates a hardware problem.

Dplx Freq. Frequency of duplex.

Measurements Resolution. Resolution of the power received (Prx) and transmitted (Ptx): • Ptx. Resolution used to communicate the changes of the power transmitted by the equip-

ment (Ptx) to a possible external management program (trap Ptx change).For instance, if the operator sets a resolution of 2 dB and the last communicated Ptx valuecorresponds to 10 dBm, the equipment will communicate to the program the changing of thetransmitted power when the Ptx gets a value < 8 or > 12.

• Prx. Resolution used to communicate the changes of the power received by the equipment(Prx) to a possible external management program (trap Prx change).For instance, if the operator sets a resolution of 2 dB and the last communicated PRx valuecorresponds to -70 dBm, the equipment will communicate to the program the changing ofthe transmitted power when the PRx gets a value <-72 or > -68.

Tx Transmitter. Operating status of the transmitter:• On. The transmitter is turned on. • Off. The transmitter is turned off. • Permanent Off. The transmitter is turned off in permanent mode.

Carrier Only. Modulation status of the RF carrier:• On. The carrier is not modulated. • Off. The carrier is modulated.

Push-button:Freq. Table. Display the table of the preferential frequencies.

Related TopicsVerify/modify the frequency which the equipment transmitter is tuned on (Tx Freq)Verify/modify the duplex frequency (Dplx Freq) Verify/modify the modulation status of the RF carrier (Carrier Only) Verify/modify the operation of the transmitter (Tx Transmitter) Verify/modify the resolution of the received power (Prx) (Measurements Resolutions) Verify/modify the resolution of the transmitted power (Ptx) (Measurements Resolutions)

Page 151: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 149

Powers tab

The tab displays the radio parameters (ATPC).

Tx Power Control. Operating status of the ATPC device:• Manual. The ATPC device is in manual functioning mode (ATPC function disable). • Automatic. The ATPC device is in automatic functioning mode.

Max Ptx <current value> dBm. Maximum output power value at the transmitter. The parameter af-fects the ATPC device both if this is excluded or active.

ATPC Regulation <current value> dB. Range of the ATPC regulation (expressed in dB) with respectto the current value of maximum Tx output, that is intended as the upper limit of the range.Parameter available only if the ATPC device is in automatic functioning mode (Tx Power Control param-eter - Automatic value).

ATPC Thresholds on Local PRx. ATPC thresholds:• High: <current value> dBm. Threshold of the ATPC device to decrease the transmitted pow-

er when the received field from the local equipment is equal to or higher than the set thresh-old value

• Low: <current value> dBm. Threshold of the ATPC device to increase the transmitted powerwhen the received field from the local equipment is equal to or lower than the set thresholdvalue.

Related TopicsVerify/modify ATPC operating status (Tx Power Control) Verify/modify the maximum output power value at the transmitter (Max Ptx) Verify/modify the ATPC regulation range (ATPC Regulation) Verify/modify the thresholds of ATPC device (ATPC Thresholds on Local PRx)

Page 152: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

150 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

MAINTENANCE

Lan Statistics. It manages the trend of the traffic on the Ethernet ports, displaying all the counters ofpackets/bytes in input/output, subdivided by single port.Lan Stat. Summary. It manages the trend of the traffic on the Ethernet ports, displaying, at the sametime, the main counters of packets/bytes in input/output for each single port.Advanced Stat. Mon. It manages the trend of the traffic on the Ethernet ports, displaying, at the sametime, the main counters of packets/bytes in input/output for each single port. The trend of the trafficcan be filtered according to specific user-defined criteria.RMon. It manages the statistic counters of the Ethernet ports of the equipment.S/N Meas. It displays the measure of the signal/noise ratio (S/N).Radio BER. It manages the measure of Radio BER value.Radio Loop. It manages the radio loops.

Page 153: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 151

Lan Statistics

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Lan Statistics command manages the trend of the traffic on the Ethernet ports displaying all thecounters of packets/bytes in input/output, subdivided by single port.In detail, the command allows:

Verify the counters of the packets/bytes in input/output from the Ethernet ports subdivided by eachportReset the counters’ results

The selection of the command displays the Lan Statistics contextual area

Verify the counters of the packets/bytes in input/output from the Ethernet ports subdivided by each port

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > Lan Statistics.The Lan Statistics contextual area displays the trend of the traffic on the Ethernet ports, displaying allthe counters of packets/bytes in input/output, subdivided by single port.

Reset the counters’ results

User Profile | Station Operator, System

1. Select Maintenance > Lan Statistics.

2. Press Reset and confirm. All the counters of all the Ethernet ports are set to zero.

Page 154: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

152 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Lan Statistics contextual area

The contextual area shows the trend of the traffic on the Ethernet ports, displaying all the counters of pack-ets/bytes in input/output, subdivided by single port.

It is possible to display only the counters of a single port at a time: the port is pointed out in the box onleft top.

To display the counters of a different Ethernet port, set the wished port in the box.Below the selected port, the list of the relevant counters is displayed with the corresponding value.The value of the each counter refers to the moment when the relevant port is selected or the context isupdated. To update the data, press Refresh.

Notes relevant to the counters The depth of the events stored by each single counter is equal to 2^32.The counters are in compliance with the specification RFC 2819.The Total Byte Received counter, differently from what specified in RFC 2819, does not include thebytes belonging to packets of sizes greater than the Max Packet Size.

Counters list

Dropped Frame (or Event). Total number of events (frames) in which packets were dropped by theprobe due to lack of resources. This value is not necessarily the absolute number of discarded packets,as it represents only the number of times that this condition occurred after the exhaustion of the mem-ory resources; the packets can be discarded also for other causes.

Total Byte Received. Total number of octets of data (including those in bad packets) received on thenetwork. This value includes 4 FCS octets.

Total Frames Received. Total number of packets (including bad packets, broadcast packets, and mul-ticast packets) received.

Broadcast Frames Received. Total number of good packets received that were directed to the broad-cast address. This does not include multicast packets.

Multicast Frames Received. Total number of good packets received that were directed to a multicastaddress. This number does not include packets directed to the broadcast address.

CRC Align Errors. Total number of packets received that had a length of between 64 and n (parameterMax Packet Size, it can be set to 1522 or 2048) octets with bad Frame Check Sequence (FCS) and anintegral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (AlignmentError).

Undersize Frames. Total number of packets received that were less than 64 octets long and wereotherwise well formed.

Oversize Frames. Total number of packets received that were longer than n (parameter Max PacketSize, it can be set to 1522 or 2048) octets and were otherwise well formed.

Fragments. Total number of packets received that were less than 64 octets in length and had eithera bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with anon-integral number of octets (Alignment Error).

Jabbers. Total number of packets received that were longer than n (parameter Max Packet Size, it canbe set to 1522 or 2048) octets, and had either a bad Frame Check Sequence (FCS) with an integralnumber of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

Collisions. The best estimate of the total number of collisions on this EthLannet segment.

Frames 64 Oct. [Sent+Rec.]. Total number of packets (including bad packets) received and trans-mitted that were 64 octets in length.

Frames 65 to 127 Oct. [Sent+Rec.]. Total number of packets (including bad packets) received andtransmitted that were between 65 and 127 octets in length inclusive.

Frames 128 to 255 Oct. [Sent+Rec.]. Total number of packets (including bad packets) received andtransmitted that were between 128 and 255 octets in length inclusive.

Page 155: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 153

Frames 256 to 511 Oct. [Sent+Rec.]. Total number of packets (including bad packets) received andtransmitted that were between 256 and 511 octets in length inclusive.

Frames 512 to 1023 Oct. [Sent+Rec.]. Total number of packets (including bad packets) receivedand transmitted that were between 512 and 1023 octets in length inclusive.

Frames 1024 to max pck size [Sent+Rec.]. Total number of transmitted and received packets witha length greater than 1024 octets (incorrect packets included).

Late Collisions. Evaluation relevant to the total number of collisions detected in this EthLannet seg-ment, after the transmission of more than 512 bits from the beginning of TXEnable.

Valid Bytes Received. Total number of received bytes relevant to correct packets. This counter is in-creased once for every data octet of good packets (Unicast + Multicast + Broadcast) received.

Bytes Sent. Number of transmitted bytes. This counter is increased once for every data octet of atransmitted good packet.

Valid Frames Received. Number of received correct frames. This counter is increased once for everygood packet (Unicast + Multicast + Broadcast) received.

Frames Sent. Number of transmitted frames. This counter is increased once for every transmittedgood packet.

Out Multicast Frames. Number of Multicast frames sent. This counter does not include Broadcastpackets.

Out Broadcast Frames. Number of Broadcast frames sent.

Out Unicast Frames. Number of Unicast frames sent. This is given by: Frames Sent - Out MulticastFrames - Out Broadcast Frames.

In Pause Frames. Number of good Flow Control frames received.

Out Pause Frame. Number of Flow Control frames sent.

Push-button:Refresh. Update the counters’ results.Reset. Reset the counters’ results.Help. Open the help on-line.

Page 156: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

154 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Lan Stat. Summary

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Lan Stat. Summary command manages the trend of the traffic on the Ethernet ports displaying, atthe same time, the main counters of packets/bytes in input/output for every port.In detail, the command allows:

Verify the summary of the main counters of the Ethernet portsReset the counters’ results

The selection of the command displays the Lan Stat. Summary contextual area

Verify the summary of the main counters of the Ethernet ports

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > Lan Stat. Summary.The Lan Stat. Summary contextual area displays the summary of the main counters of the Ethernetports.

Reset the counters’ results

User Profile | Station Operator, System

1. Select Maintenance > Lan Stat. Summary.

2. Press Reset All and confirm. All the counters of all the Ethernet ports are set to zero.

Page 157: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 155

Lan Stat. Summary contextual area

The table present in the contextual area, displays the summary of the main counters of the Ethernet ports.Every table row corresponds to a counter. For every counter is displayed in the column:

Parameter. Counter name:• Byte Received (Total Byte Received). Total number of octets of data (including those in bad

packets) received on the network. This value includes 4 FCS octects.• Frame Received (Total Frame Received). Total number of packets (including bad packets,

broadcast packets, and multicast packets) received. • Byte Sent. Number of transmitted bytes. This counter is increased once for every data octet

of a transmitted good packet.• Frame Sent. Number of transmitted frames. This counter is increased once for every trans-

mitted good packet.• Dropped Frame (or Event). Total number of events (frames) in which packets were dropped

by the probe due to lack of resources. This value is not necessarily the absolute number ofdiscarded packets, as it represents only the number of times that this condition occurred af-ter the exhaustion of the memory resources; the packets can be discarded also for othercauses.

• CRC Err. (CRC Align Errors). Total number of packets received that had a length of between64 and n (parameter Max Packet Size, it can be set to 1522 or 2048) octets with bad FrameCheck Sequence (FCS) and an integral number of octets (FCS Error) or a bad FCS with anon-integral number of octets (Alignment Error).

Notes relevant to the countersThe depth of the events stored by each single counter is equal to 2^32.The counters are in compliance with the specification RFC 2819. The Byte Received counter, differ-ently from what specified in RFC 2819, does not include the bytes belonging to packets of sizesgreater than the Max Packet Size.

Lan1, Lan2, PortA. Value of the counters with respect to every single port of the Ethernet Switch.The value of each counter refer to the moment when the context is opened or updated.

Push-button:Refresh. Update the counters’ results.Reset All. Reset the counters’ results.Help. Open the help on-line.

Page 158: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

156 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Advanced Stat. Mon.

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Advanced Stat. Mon. command manages the trend of the traffic on the Ethernet ports displaying themain counters of packets/bytes in input/output subdivided for the Radio port. The trend of the traffic canbe filtered according to specific user-defined criteria.In detail, the command allows:

Verify/manage the main counters of the Radio port whose traffic is filtered according to Internal PriorityvalueVerify/manage the main counters of the Radio port whose traffic is filtered according to C-VID identifierVerify/manage the main counters of the Radio port whose traffic is filtered according to the S-VID andC-VID identifiers

The selection of the command displays the Advanced Stat. Mon. contextual area.

Verify/manage the main counters of the Radio port whose traffic is filtered according to Internal Priority value

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Maintenance > Advanced Stat. Mon.

2. Press the Show Port A .Press to compress the Advanced Stat. Mon. window. Press to expand the window.

3. If not already present, set the value Internal Priority in the Select Group field.The meaning of Internal Priority refers to its association with the possible manageable priorities(802.1p, TOS/DSCP...) and the corresponding selected queue.If the Select Group parameter cannot be changed, this means that the supervision system NMS5UX/NMS5UX-B/NMS5LX has activated the RMon count at service level.

The following counters are displayed in the Counters column:• Frame Sent. Number of transmitted correct frames. This counter is increased once for every

good packet (Unicast + Multicast + Broadcast) transmitted. • Byte Sent. Total number of transmitted bytes relevant to correct packets. This counter is in-

creased once for every data octet of good packets (Unicast + Multicast + Broadcast) transmit-ted.

• 64 (Tx) Byte. Total number of transmitted packets that were 64 octets in length. • 65 to 127 (Tx) Byte. Total number of transmitted packets that were between 65 and 127 octets

in length inclusive • 128 to 255 (Tx) Byte. Total number of transmitted packets that were between 128 and 255 oc-

tets in length inclusive. • 256 to 511 (Tx) Byte. Total number of transmitted packets that were between 256 and 511 oc-

tets in length inclusive • 512 to 1023 (Tx) Byte. Total number of transmitted packets that were between 512 and 1023

octets in length inclusive. • 1024 to Max Pkt size (Tx) Byte. Total number of transmitted packets with a length greater than

1024 octets. Notes relevant to the counters

The depth of the events stored by each single counter is equal to 2^32. The counters are in com-pliance with the specification RFC 2819.

The Internal Priority columns display the values of the counters relevant only to Ethernet packets withthe specific priority.The value of the each counter refers to the moment when the relevant port is selected or the contextis updated. To update the data, press Refresh.

Page 159: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 157

The counter Total Transmitted Frames indicates the total number of transmitted frames. Press RefreshTransmitted Frame to update the value.

4. If the Advanced Stat. Mon. <Ethernet port> window contains only the Counters column or the InternalPriority column is not present, it is necessary to add the column in the following way:

a. Press Add.

b. Set, in the Internal Priority field, the wished value of priority (number between 0 and 7).If the Add All box becomes active, one column will be inserted for every value of Internal Priority(Int.Prio. 1... Int.Prio. 7) in the Advanced Stat. Mon. <Ethernet port> window.

c. Press OK and confirm.The Advanced Stat. Mon. <Ethernet port> window displays, next to the Counters column, theInternal Priority <value> column.

Repeat the step 4 to create the columns relevant to the wished values of priority 802.1p.

The columns relevant to the priority values will remain set until when the user removes them or thecriterion used to filter the traffic is changed (change of the value for the Select Group parameter).

In the heading of the columns created by operator there is the symbol ( ). Selecting it, the followingcommands are displayed:

• Sort Ascending. Sort in ascending order (from lowest to greatest value) the rows of the tablewith respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Sort Descending. Sort in descending order (from greatest to lowest value) the rows of the ta-ble with respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Columns. Active ( ) and deactive ( ) the display of a column in the table.• Refresh. Update the values of the counters present in the specific column.• Remove. Remove the specific column.• Reset. Reset the values of the counters present in the specific column.

In the Advanced Stat. Mon. <Ethernet port> window, the push-button:• Remove All. Remove all the Internal Priority columns set by the user.• Refresh. Update the values of the counters present in all the Internal Priority columns.• Reset. Reset the values of the counters present in all the Internal Priority columns.

Verify/manage the main counters of the Radio port whose traffic is filtered according to C-VID identifier

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Maintenance > Advanced Stat. Mon.

2. Press the Show Port A .Press to compress the Advanced Stat. Mon. window. Press to expand the window.

3. If not already present, set the value C Vid in the Select Group field.If the Select Group parameter cannot be changed, this means that the supervision system NMS5UX/NMS5UX-B/NMS5LX has activated the RMon count at service level.

The Counters column displays the following counters:• Received Frame. Total number of received frames. • Received Byte. Total number of octets of data received on the network. This value includes 4

FCS octets.• Frame Sent. Number of transmitted frames. This counter is increased once for every transmitted

good packet.

Page 160: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

158 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

• Byte Sent. Number of transmitted bytes. This counter is increased once for every data octet ofa transmitted good packet

• 64 (Tx + Rx) Byte. Total number of transmitted and received packets that were 64 octets inlength.

• 65 to 127 (Tx + Rx) Byte. Total number of transmitted and received packets that were between65 and 127 octets in length inclusive

• 128 to 255 (Tx + Rx) Byte. Total number of transmitted and received packets that were between128 and 255 octets in length inclusive.

• 256 to 511 (Tx + Rx) Byte. Total number of transmitted and received packets that were between256 and 511 octets in length inclusive

• 512 to 1023 (Tx + Rx) Byte. Total number of transmitted and received packets that were be-tween 512 and 1023 octets in length inclusive.

• 1024 to Max Pkt size (Tx + Rx) Byte. Total number of transmitted and received packets with alength greater than 1024 octets.

Notes relevant to the countersThe depth of the events stored by each single counter is equal to 2^32. The counters are incompliance with the specification RFC 2819. .

The <C-VID identifier> columns (for example 6) point out the values of the counters relevant only toEthernet packets with the specific C-VID (Customer VLAN Identifier) identifier.The value of the each counter refers to the moment when the relevant port is selected or the contextis updated. To update the data, press Refresh.

The counter Total Transmitted Frames indicates the total number of transmitted frames. Press RefreshTransmitted Frame to update the value.

4. If the Advanced Stat. Mon. <Ethernet port> window contains only the Counters column or the <C-VIDidentifier> column relevant to the wished C-VID value is not present, it is necessary to add the columnin the following way:

a. Press Add.

b. Set, in the C Vid field, the wished C-VID value (number between 2 and 4094), press OK andconfirm.The Advanced Stat. Mon. <Ethernet port> window displays the <C-VID identifier> column nextto Counters column.

Repeat the step 4 to create the columns relevant to the wished C-VID values.

The columns relevant to the C-VID values will remain set until when the user removes them or the cri-terion used to filter the traffic is changed (change of value for the parameter Select Group).

In the heading of the columns created by operator there is the symbol ( ). Selecting it, the followingcommands are displayed:

• Sort Ascending. Sort in ascending order (from lowest to greatest value) the rows of the tablewith respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Sort Descending. Sort in descending order (from greatest to lowest value) the rows of the ta-ble with respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Columns. Active ( ) and deactive ( ) the display of a column in the table.• Refresh. Update the values of the counters present in the specific column.• Remove. Remove the specific column.• Reset. Reset the values of the counters present in the specific column.

In the Advanced Stat. Mon. <Ethernet port> window, the push-button:• Remove All. Remove all the <C-VID identifier> columns set by the user.• Refresh. Update the values of the counters present in all the <C-VID identifier> columns.• Reset. Reset the values of the counters present in all the <C-VID identifier> columns.

Page 161: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 159

Verify/manage the main counters of the Radio port whose traffic is filtered according to the S-VID and C-VID identifiers

User Profile | Verify: Monitor, Read Only, Read & Write. Modify: Station Operator, System

1. Select Maintenance > Advanced Stat. Mon.

2. Press the Show Port A .Press to compress the Advanced Stat. Mon. window. Press to expand the window.

3. If not already present, set the value C Vid-S Vid in the Select Group field.If the Select Group parameter cannot be changed, this means that the supervision system NMS5UX/NMS5UX-B/NMS5LX has activated the RMon count at service level.

The following counters are displayed in the Counters column:• Received Frames. Total number of received frames. • Received Byte. Total number of octets of data received on the network. This value includes 4

FCS octets.• Frame Sent. Number of transmitted frames. This counter is increased once for every transmitted

good packet.• Byte Sent. Number of transmitted bytes. This counter is increased once for every data octet of

a transmitted good packet• 64 (Tx + Rx) Byte. Total number of transmitted and received packets that were 64 octets in

length. • 65 to 127 (Tx + Rx) Byte. Total number of transmitted and received packets that were between

65 and 127 octets in length inclusive • 128 to 255 (Tx + Rx) Byte. Total number of transmitted and received packets that were between

128 and 255 octets in length inclusive. • 256 to 511 (Tx + Rx) Byte. Total number of transmitted and received packets that were between

256 and 511 octets in length inclusive • 512 to 1023 (Tx + Rx) Byte. Total number of transmitted and received packets that were be-

tween 512 and 1023 octets in length inclusive. • 1024 to Max Pkt size (Tx + Rx) Byte. Total number of transmitted and received packets with a

length greater than 1024 octets.

Notes relevant to the countersThe depth of the events stored by each single counter is equal to 2^32. The counters are incompliance with the specification RFC 2819.

The <C-VID S-VID identifiers> columns (e.g. 6-9) point out the values of the counters relevant only tothe Ethernet packets with the specific C-VID (Customer VLAN Identifier) and S-VID (Service VLAN Iden-tifier) identifier The value of the each counter refers to the moment when the relevant port is selected or the contextis updated. To update the data, press Refresh.

The counter Total Transmitted Frames indicates the total number of transmitted frames. Press RefreshTransmitted Frame to update the value.

4. If the Advanced Stat. Mon. <Ethernet port> window contains only the Counters column or the <C-VIDS-VID identifier> column relevant to the wished C-VID and S-VID values is not present, it is necessaryto add the column in the following way:

a. Press Add.

b. Set the wished C-VID value (number between 2 and 4094) in the C Vid field.

c. Set the wished S-VID value (number between 2 and 4094) in the S Vid field.

d. Press OK and confirm.The Advanced Stat. Mon. <Ethernet port> window displays the <C-VID S-VID identifier> col-umn next to the Counters column.

Repeat the step 4 to create the columns relevant to the wished C-VID and S-VID values.

The columns relevant to the C-VID/S-VID values will remain set until when the user removes them orthe criterion used to filter the traffic is changed (change of value for the parameter Select Group).

Page 162: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

160 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

In the heading of the columns created by operator there is the symbol ( ). Selecting it, the followingcommands are displayed:

• Sort Ascending. Sort in ascending order (from lowest to greatest value) the rows of the tablewith respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Sort Descending. Sort in descending order (from greatest to lowest value) the rows of the ta-ble with respect to the value present in the specific column.Command available when the column contains at least one value different from 0.

• Columns. Active ( ) and deactive ( ) the display of a column in the table.• Refresh. Update the values of the counters present in the specific column.• Remove. Remove the specific column.• Reset. Reset the values of the counters present in the specific column.

In the Advanced Stat. Mon. <Ethernet port> window, the push-button:• Remove All. Remove all the <C-VID S-VID identifier> columns set by the user.• Refresh. Update the values of the counters present in all the <C-VID S-VID identifier> columns.• Reset. Reset the values of the counters present in all the <C-VID S-VID identifier> columns.

Page 163: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 161

Advanced Stat. Mon. contextual area

This contextual area allows managing the traffic flow on the Ethernet ports, displaying the main countersof the packets/bytes in input/output subdivided by single port.

Push-button:Apply. Not available in this context.Refresh. Not meaningful in this context.Help. Open the help on line.

Show Port A. Open the Advanced Stat. Mon. Port A window, where the traffic flow on the internal portcan be verified/filtered.The traffic flow is filtered depending on specific criteria defined by the user.The description of the available criteria and, depending on their setting, of the elements present in theAdvanced Stat. Mon. <Ethernet port> window is reported in the following procedures:

Verify/manage the main counters of the Radio port whose traffic is filtered according to InternalPriority valueVerify/manage the main counters of the Radio port whose traffic is filtered according to C-VID iden-tifierVerify/manage the main counters of the Radio port whose traffic is filtered according to the S-VIDand C-VID identifiers

Page 164: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

162 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

RMon

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The RMon command manages the statistic counters of the Ethernet ports of the equipment.The managed counters are described in RFC 2819 - History Control Group.In detail, the command allows:

Verify the collection status of the statistic counters of the equipment Ethernet portsActivate the collection of the statistic counters for an Ethernet portDeactivate the collection of the statistic counters for an Ethernet portDisplay the values of statistical counters of an Ethernet port

The selection of the command displays the RMon contextual area

In order to deepen this topic, see Implementation of the RMon standard in the equipment managed byWEB LCT

Verify the collection status of the statistic counters of the equipment Ethernet ports

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > RMon.The RMon contextual area displays the status of the Ethernet ports in relation to the count of the sta-tistics.

Activate the collection of the statistic counters for an Ethernet port

User Profile | Station Operator, System

1. Select Maintenance > RMon.

2. Execute one of the following actions:• Select the Ethernet port in Stopped status to be activated and press Show.• Double click on the Ethernet port in Stopped status to be activated.

3. Press Start and confirm.If the selected port is inactive (Rate Control - Disable), a warning message is displayed.The count is started-up.After the start of the measure, the display of the data relevant to the first sampling range could takemore than one minute.

Deactivate the collection of the statistic counters for an Ethernet port

User Profile | Station Operator, System

WARNING The deactivation of the count involves the loss of the collected data.

1. Select Maintenance > RMon.

2. Execute one of the following actions:• Select the Ethernet port in Running status to be deactivated and press Show.• Double click on the Ethernet port in Running status to be deactivated.

3. Press Stop and confirm.The count is stopped.

Page 165: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 163

Display the values of statistical counters of an Ethernet port

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Operation meaningful only for Ethernet ports for which the count of the RMon statistics is active.

1. Select Maintenance > RMon.

2. Execute one of the following actions:• Select the Ethernet port in Running status and press Show.• Double click on the Ethernet port in Running status.

The Remote Monitoring window displays the evolution in time (history) of the statistic counters fromthe start of the count on the specific port.More Remote Monitoring windows can be opened relevant to different Ethernet ports.

Page 166: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

164 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

RMon contextual area

The table, present in the contextual area, displays the status of the Ethernet ports in relation to the countof the statistics.Every row of the table corresponds to one port. For every port, is pointed out in the column:

Lan Port. Port of the Ethernet Switch.

Status. Port status in relation to the count of the statistics: • Stopped. The count is not on progress.• Running. The count is on progress.

Push-button:Apply. Not available in this context.Refresh. Update the context.Help. Open the help on line.

Show. Open the Remote Monitoring window.

Related TopicsActivate the collection of the statistic counters for an Ethernet portDeactivate the collection of the statistic counters for an Ethernet portDisplay the values of statistical counters of an Ethernet port

Implementation of the RMon standard in the equipment managed by WEB LCT

Remote Monitoring window

The window shows the statistics counting of the specific port.

In the window there is a table.Every row of the table corresponds to a sampling period of 60 seconds (displayed in Time column).The other columns display the value of the counter in the specific sampling period. For the description ofthe counter refer to par. Ethernet counters (RMon).For the Octets(Rx) counter between brackets, the number of bytes within a second (kB/s) is pointed out.

The statistic counters of the considered Ethernet port are freezed by the equipment each minute.For each port, the equipment can store a maximum of 240 samples (corresponding to 4 hours). When themaximum value is reached, the new data will overwrite the oldest ones.At the end of a sampling interval, for each counter, the pointed out value corresponds to the value regis-tered during the measuring interval.

If the count is disable the table will be empty.

Selecting the heading of a column, the symbol ( ) is displayed. Selecting it, the following commands aredisplayed:

Sort Ascending. Not available in this context.Sort Descending. Not available in this context.Columns. Active ( ) and deactive ( ) the display of a column in the table.

Push-button:Start. Activate the collection of the statistic counters for an Ethernet port. Push-button displayed inalternative to the Stop.Stop. Deactivate the collection of the statistic counters for an Ethernet port. Push-button displayed inalternative to the Start.Refresh. Update the data.

Page 167: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 165

Freeze. Interrupt the dynamic display of the values in the window (freezes the window). Push-buttondisplayed in alternative to the Unfreeze. When the window is opened, the dynamic display of the val-ues is active by default.Unfreeze. Re-activates the dynamic display of the values in the window. Push-button displayed in al-ternative to the Freeze.

The List Update in: x sec parameter indicates the seconds (x value) missing to the end of the currentsampling interval, at the end of which the new row is displayed.The wording List Update in: sec indicates that the window is freezed (see Freeze/Unfreeze push-button).

Page 168: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

166 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Implementation of the RMon standard in the equipment managed by WEB LCT

ALFOplus80 equipment implements the RMon standard with the modalities described here below:RMon StandardOutline on the operation of RMon standardManagement from Web LCT of the statistics counters foreseen by RMON standardEthernet counters (RMon)

RMon Standard

RMon (Remote Monitoring) is a standard whose function is providing a set of services of statistics count,monitoring and alarm report with reference to the activity of a LAN network.These services are defined in terms of MIB (Management Information Base) group described in the docu-ment RFC2819 - Remote Network Monitoring Management Information Base, which must be read for anyfurther detail.

Outline on the operation of RMon standard

The RMon standard is based on two components: an agent (RMon probe) and a client (remote managementstation).The agent saves the data within its own RMon tables present on the network devices (equipment, routers,etc.). The RMon probes can see only the traffic flowing through themselves and therefore are located oneach (internal/external) port of the Ethernet Switch of the device to monitor.The remote management station communicates with the RMon agent to obtain and correlate the RMon da-ta. Generally, the station is equipped with an interface (graphic or textual) which allows the display andthe analysis of the collected RMon data.

Management from Web LCT of the statistics counters foreseen by RMON standard

With reference to what depicted in the previous paragraph, the RMon functionality allows the analysis ofthe data collected by the probes present on each (internal/external) port of the Ethernet Switch of theequipment in compliance with the RMon standard (RMon MIB group: History).In order to store in the equipment and display the statistics history of a port, it is necessary to activate themeasure on the port (see Activate the collection of the statistic counters for an Ethernet port). The collec-tion of the statistic counters on this port will remain active until when an user (WEB LCT or SCT/LMT) doesnot deactivate it (see Deactivate the collection of the statistic counters for an Ethernet port).Once the measure is activated, the probes collect the statistic data, which are stored in the RMon table ofthe equipment. The storing takes place each 60 seconds (sampling range).The equipment stores these data into a rotation buffer where, when full, the new information overwritesthe old ones (value set to 240 samples which allow storing 4 hours in the equipment).The data relevant to the statistics are available to the user and displayed, in form of table, subdivided bysingle Ethernet port (see Display the values of statistical counters of an Ethernet port).WEB LCT displays the history of the last two hours with intervals of 1 minute.During the count, the display of the data in the Remote Monitoring <porta Ethernet> window can be inter-rupted. This operation does not interrupt the count, but freezes only the data present in the window. Infact, when the data update is re-activated, the window displays the values of all the sampling ranges (upto a maximum of 120), even those stored in the equipment while the window was freezed.

Page 169: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 167

Ethernet counters (RMon)

The description of the counters is the same reported for the counters of the packets/bytes in input/outputfrom an Ethernet port (see Lan Statistics).The only difference is the name of the counter which, in some cases, change from the RMon counters withrespect to the Lan Statistics counters.Ethernet counters denomination (RMon) reports the correspondence of the names for the Ethernet RMoncounters.

The counter Utilization is meaningful only as RMon counter and has the following definition: estimate ofthe average utilization of the port in the sampling interval expressed as hundredths of percentage.

The percentage of usage of the radio port refers to the bit rate of the port at the Switch (1Gbit/s) and notto the available radio band.

The percentage of usage of the LANs instead refers to the real bit rate of the port (10Mbit/s, 100Mbit/s or1Gbit/s).

Tab.7 Ethernet counters denomination (RMon)

Ethernet counters denominationRMon - History

Ethernet counters denominationLan Statistics

Drop Events Dropped Frame

Octects (Rx) (kB/s) Total Byte Received

Pkts (Rx) Total Frame Received

Broadcasts (Rx) Broadcast Frame Received

Multicasts (Rx) Multicast Frame Received

CRC Align Errors CRC Align Errors

Undersize Pkts Undersize Frame

Oversize Pkts Oversize Frame

Fragments Fragments

Jabbers Jabbers

Collisions Collisions

Utilization (Rx) (%) -

Octects (Tx) (kB/s) Byte Sent

Pkts (Tx) Frame Sent

Broadcasts (Tx) Out Broadcast Frame

Multicasts (Tx) Out Multicast Frame

Utilization (Tx) (%) -

Page 170: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

168 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

S/N Meas

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The S/N Meas command displays the measure of the signal/noise ratio (S/N), which allows evaluating thequality of the radio communication channel.In detail, the command allows:

Verify the value of the S/N measureUpdate the value of the S/N measure

The selection of the command displays the S/N Meas. contextual area

Verify the value of the S/N measure

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > S/N Meas.The S/N Meas. contextual area displays the value of the signal/noise ratio.

Update the value of the S/N measure

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > S/N Meas.The S/N parameter indicates the value of the signal/noise ratio.

2. Press Refresh to update the value.

Page 171: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 169

S/N Meas. contextual area

The contextual area shows the value of the S/N measure.

S/N. Value of the signal/noise ratio.The measure is always in progress.

Push-button:Refresh. Update the value of the S/N measureHelp. Open the help on-line.

Page 172: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

170 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Radio BER

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

The Radio BER command allows verifying the quality of the signal received by the equipment.In detail, the command allows:

Verify the status and the configuration parameters of Radio BER measureActivate the measure (BER and error count)Deactivate the measure (BER and error count)

The selection of the command displays the Radio BER contextual area.

Verify the status and the configuration parameters of Radio BER measure

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > Radio BER.The Radio BER contextual area displays the status and the configuration parameters of Radio BERmeasure.

Activate the measure (BER and error count)

User Profile | Read & Write, Station Operator, System

WARNING The operation is traffic affecting. Operation of maintenance (MAN. OP).

1. Select Maintenance > Radio BER.

2. Select the On option (Test Mode parameter). A message warns that the activation of the measure will involve the loss of the radio link and, as con-sequence, the connection with the remote equipment.

3. Confirm the operation.

4. Press Apply.A message warns that you are executing a forcing and shows the current setting of timeout.

5. Confirm the operation.The activation of measure activates the MAN. OP. alarm. If the equipment is switched off and thenswitched on again, the measure is inactive independently from the previous setting.

6. Press Start Measure and confirm.To restart the measure (reset of BER and number of errors), press Start Measure and confirming.

Deactivate the measure (BER and error count)

User Profile | Read & Write, Station Operator, System

1. Select Maintenance > Radio BER.

2. Select the Off option (Test Mode parameter).

3. Press Apply and confirm.

Page 173: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 171

Radio BER contextual area

The contextual area shows the status and the configuration parameters of Radio BER measure.

BER. Bit Error Rate: ratio between the number of received errored bits and the number of total receivedbits. BER value is dynamically updated during the measure.

Errors. Number of errors detected from the start of the measure.

Elapsed Time. Time (expressed in seconds) range after the measure active.

Synch Loss events. Number of times that the Sync Loss Alarm activated from the start of the meas-ure.

Sync Loss Alarm. Status of Synch Loss alarm.The colour of the boxes represents the alarm status and severity:

• Red, Orange, Yellow, Light blue. Alarm activated coupled respectively with the Critical, Ma-jor, Minor, Warning severity.

• Green. Alarm activated coupled with the Status severity level.• Grey. Alarm deactivated.

Test Mode. Activation status of the measure:• On. The Radio BER measure is active. • Off. The Radio BER measure is deactivated.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Start Measure. Start o restart the measure.

Related TopicsActivate the measure (BER and error count)Deactivate the measure (BER and error count)

Page 174: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

172 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Radio Loop

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

WARNING Setting a specific management configuration involves a different effect of the loops on how thesupervision is hold for every port of the Ethernet Switch (see Management configurations (info) and Tab.8).

The Radio Loop command manages the radio loops. In detail, the command allows:

Verify the radio loops statusActivate a radio loopDeactivate a radio loop

The selection of the command displays the Radio Loop contextual area

In order to deepen this topic, see Loop (info)

Verify the radio loops status

User Profile | Monitor, Read Only, Read & Write, Station Operator, System

1. Select Maintenance > Radio Loop.The Radio Loop contextual area displays the current status of the radio loops.

Activate a radio loop

User Profile | Read & Write, Station Operator, System

WARNING Operation of maintenance (MAN. OP).The activation of the radio loop can affect the traffic and the supervision (see Tab.8).

1. Select Maintenance > Radio Loop.

2. Select the option relevant to the loop that you want to activate.It is not possible to set more loops at the same time, the selection of an option automatically disablesthe previously selected one.

3. Press Apply.A message warns that you are executing a forcing and shows the current setting of timeout.

4. Confirm the operation. The activation of a loop activates the MAN. OP alarm. If the equipment is turned off and then turnedon again, the loop results deactivated independently from the previous setting.

Deactivate a radio loop

User Profile | Read & Write, Station Operator, System

1. Select Maintenance > Radio Loop.

2. Select the Loop OFF option.

3. Press Apply and confirm.

Page 175: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 173

Radio Loop contextual area

The contextual area shows the current status of the radio loops.

Loop. Status of the loops:• Loop OFF. No loop active.• I/Q Loop. Radio loop executed before the modulation and RF amplification block: Ethernet

traffic is not looped.• I/Q Loop (ETH not squelched). Radio loop executed before the modulation and RF amplifica-

tion block: Ethernet traffic is looped. • Base Band Loop (ETH not squelched). Base band loop active: Ethernet traffic is looped.

Push-button:Apply. Confirm the changes.Refresh. Update the context.Help. Open the help on-line.

Related TopicsActivate a radio loopDeactivate a radio loop

Loop (info)

Page 176: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

174 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Loop (info)

WARNING The activation of the radio loop affects the traffic.Before activating a loop, it is suggested to verify that the timeout of the manual operations is set. If thetimeout is not active, the loop will be active until its deactivation by the user, the switch-off/switch-on ofthe equipment or the equipment reset.

The ports of the Ethernet Switch of ALFOplus80 equipment can be configured for the transport of the trafficonly or for the contemporary transport of the traffic and of the supervision (see Management configurations(info).Setting a specific management configuration involves a different effect of the loops on how the supervisionis hold for every port of the Ethernet Switch, as indicated in Tab.8.

Tab.8 Effect of loops with respect to the management configurations

Legend. OK The transport of supervision through the port is not compromised by the activation of the loopLost The transport of supervision through the port is compromised by the activation of the loop NS Theport does not transport supervision NA Not Available (loop not available).

Managementconfiguration

Loop Supervision of local equipment through

LAN 1 LAN2 Port A

Lan1 DisabledLan2 Local Access Only

LAN 1 - Line Loop NS OK NS

LAN 2 - Line Loop NA NA NA

I/Q Loop NS OK NS

I/Q Loop (ETH not squelched) NS OK NS

Base Band Loop (ETH not squelched) NS OK NS

Lan1 DisabledLan2 Out Of Band

LAN 1 - Line Loop NS OK OK

LAN 2 - Line Loop NA NA NA

I/Q Loop NS OK Lost

I/Q Loop (ETH not squelched) NS OK Lost

Base Band Loop (ETH not squelched) NS OK Lost

Lan1 In BandLan2 Local Access Only

LAN 1 - Line Loop Lost OK OK

LAN 2 - Line Loop NA NA NA

I/Q Loop OK OK Lost

I/Q Loop (ETH not squelched) Lost OK Lost

Base Band Loop (ETH not squelched) Lost OK Lost

Lan1 In BandLan2 Drop Node

LAN 1 - Line Loop Lost OK OK

LAN 2 - Line Loop NA NA NA

I/Q Loop OK OK Lost

I/Q Loop (ETH not squelched) Lost OK Lost

Base Band Loop (ETH not squelched) Lost OK Lost

Lan1 In BandLan2 In Band

LAN 1 - Line Loop Lost OK OK

LAN 2 - Line Loop OK Lost OK

I/Q Loop OK OK Lost

I/Q Loop (ETH not squelched) Lost Lost Lost

Base Band Loop (ETH not squelched) Lost Lost Lost

Lan1 In BandLan2 Disabled

LAN 1 - Line Loop Lost NS OK

LAN 2 - Line Loop OK NS OK

I/Q Loop OK NS Lost

I/Q Loop (ETH not squelched) Lost NS Lost

Base Band Loop (ETH not squelched) Lost NS Lost

Page 177: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 175

ALARMS LIST

Tab.9 indicates the list of the alarms relevant to ALFOplus80 equipment.

The alarms are not listed in alphabetical order but they are grouped according to the corresponding partsof the equipment. In detail:

EquipmentCommonEth LanP.M. G.828P.M. Rx PowerP.M. Tx PowerRadioPlug-in moduleSETSUnit

For each alarm, the wording present in the Events area (see Equipment status area) of the WEB LCT pageand the wording present in the Alarm Severity Config. contextual area are displayed.

Some alarms have some wordings in italic contained between the symbols < >. They, in the alarm dis-played in the Events area, represent a variable.

The symbol “-“means that the alarm is not meaningful for the Alarm Severity Config. contextual area.

Page 178: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

176 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Tab.9 - Alarms list

Events alarms Alarm Severity Config.

Equipment

Equip. Alarm Synthesis Critical -

Equip. Alarm Synthesis Major -

Equip. Alarm Synthesis Minor -

Equip. Alarm Synthesis Warning -

Common

Equip Manual Operation equipManualOperation

WAKE UP Manager IP address: <IP address> -

Eth Lan

BASE BAND Link Loss Forwarding Alarm ethLanPhyLinkLossForwarding

BASE BAND Loss of Signal Alarm ethLanPhyLinkLoss

BASE BAND Master-Slave Configuration fault Alarm ethLanPhyMasterSlaveConfigurationFault

BASE BAND Physical Coding Sublayer Sync Alarm ethLanPhySync

BASE BAND Unresolved Autonegotiation Alarm ethLanPhyAutoNegotiation

BASE BAND Link Aggregation LACP protocol down ethLanPhyLagLacpProtocolDown

P.M. G.828

P.M. RADIO G.828 15Mcounter ES threshold cross Alarm pmG828-15MEsAlarm

P.M. RADIO G.828 15Mcounter SEP threshold cross Alarm pmG828-15MSepAlarm

P.M. RADIO G.828 15Mcounter SES threshold cross Alarm pmG828-15MSesAlarm

P.M. RADIO G.828 24Hcounter ES threshold cross Alarm pmG828-24HEsAlarm

P.M. RADIO G.828 24Hcounter SEP threshold cross Alarm pmG828-24HSepAlarm

P.M. RADIO G.828 24Hcounter SES threshold cross Alarm pmG828-24HSesAlarm

P.M. RADIO G.828 UAS Alarm pmG828-UASAlarm

P.M. Rx Power

P.M. RADIO RxPower 15Mcounter Rlts1 threshold cross Alarm pmRxPwr-15MRltsAlarm

P.M. RADIO RxPower 15Mcounter Rlts2 threshold cross Alarm pmRxPwr-15MRlts2Alarm

P.M. RADIO RxPower 15Mcounter Rlts3 threshold cross Alarm pmRxPwr-15MRlts3Alarm

P.M. RADIO RxPower 15Mcounter Rlts4 threshold cross Alarm pmRxPwr-15MRlts4Alarm

P.M. RADIO RxPower 15Mcounter Rlts5 threshold cross Alarm pmRxPwr-15MRlts5Alarm

P.M. RADIO RxPower 24Hcounter Rlts1 threshold cross Alarm pmRxPwr-24HRltsAlarm

P.M. RADIO RxPower 24Hcounter Rlts2 threshold cross Alarm pmRxPwr-24HRlts2Alarm

P.M. RADIO RxPower 24Hcounter Rlts3 threshold cross Alarm pmRxPwr-24HRlts3Alarm

P.M. RADIO RxPower 24Hcounter Rlts4 threshold cross Alarm pmRxPwr-24HRlts4Alarm

P.M. RADIO RxPower 24Hcounter Rlts5 threshold cross Alarm pmRxPwr-24HRlts5Alarm

P.M. Tx Power

P.M. RADIO TxPower 15Mcounter Tlts1 threshold cross Alarm pmTxPwr-15MTltsAlarm

Page 179: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 177

P.M. RADIO TxPower 15Mcounter Tlts2 threshold cross Alarm pmTxPwr-15MTlts2Alarm

P.M. RADIO TxPower 15Mcounter Tlts3 threshold cross Alarm pmTxPwr-15MTlts3Alarm

P.M. RADIO TxPower 15Mcounter Tlts4 threshold cross Alarm pmTxPwr-15MTlts4Alarm

P.M. RADIO TxPower 24Hcounter Tlts1 threshold cross Alarm pmTxPwr-24HTltsAlarm

P.M. RADIO TxPower 24Hcounter Tlts2 threshold cross Alarm pmTxPwr-24HTlts2Alarm

P.M. RADIO TxPower 24Hcounter Tlts3 threshold cross Alarm pmTxPwr-24HTlts3Alarm

P.M. RADIO TxPower 24Hcounter Tlts4 threshold cross Alarm pmTxPwr-24HTlts4Alarm

Radio

Ber Sync Loss Alarm radioEquipBerSyncLossAlarm

Link Id. Alarm radioEquipLinkIdAlarm

Link Telemetry Fail Alarm radioEquipLinkTelemetryFailAlarm

RADIO Invalid Frequency Alarm radioInvalidFrequencyAlarmSet

BASE BAND Rx Alarm baseBandBaseBandRxAlarmSet

RADIO Modulator Fail Alarm radioModulatorFailAlarm

RADIO Demodulator Fail Alarm radioDemodulatorFailAlarm

RADIO Rx Power Low Alarm radioRxPowerLowAlarm

RADIO Tx Power Alarm radioTxPowerAlarm

RADIO Vco Fail Alarm radioRtVcoFail

RADIO If Fail Alarm radioRtIfFail

RADIO Rx Quality Low Alarm radioRxQualityLowAlarm

RADIO Rx Quality Low Warning radioRxQualityLowWarning

RADIO Prx change radioPrxChange

RADIO Ptx change radioPtxChange

Plug-in module

[<module name>] Plug-in module Status plug-inModuleAlarm

[<module name>] Plug-in module Mismatch Alarm plug-inLosAlarm

[<module name>] Plug-in module Fail Alarm plug-inModuleMismatchAlarm

[<module name>] Plug-in module Loss of Signal Alarm plug-inStatusChange

SETS

BASE BAND Sets <name of the synchronism signal> Active Status timingSynkActiveStatus

BASE BAND Sets <name of the synchronism signal> Drift Alarm timingSynkDriftAlarm

BASE BAND Sets <name of the synchronism signal> LTI Alarm timingSynkLosAlarm

BASE BAND Sets Free Running Status timingGeneratorFreeRunningStatus

BASE BAND Sets Holdover Status timingGeneratorHoldoverStatus

BASE BAND Sets T0 Fail Alarm timingGeneratorT0FailAlarm

Unit

<unit name> Unit Fail Alarm unitFailAlarm

<unit name> Unit Hw Mismatch Alarm unitHwMismatchAlarm

<unit name> Unit Missing Alarm unitMissingAlarm

Events alarms Alarm Severity Config.

Page 180: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

178 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

(1) See Performance Monitoring

<unit name> Unit Not Responding Alarm unitNotRespondingAlarm

<unit name> Unit Sw Mismatch Alarm unitSwMismatchAlarm

Events alarms Alarm Severity Config.

Page 181: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 179

OPERATIONS LIST

AAlarms

Change the severity level of an alarm ................................................................................... 82Enable/disable an alarm ...................................................................................................... 81Enable/disable the forwarding of the trap of an alarm .............................................................. 81Verify the severity level and the enabling/forwarding status of the alarms .................................. 81

Alarms stored into the equipment controllerDelete ............................................................................................................................... 61Save to file ........................................................................................................................ 61

ATPCIntervention threshold, verify/modify ...................................................................................147Maximum output power value at the transmitter, verify/modify ...............................................146Operating status, verify/modify ...........................................................................................146Regulation range, verify/modify ...........................................................................................146

CCommunication stack

Verify ............................................................................................................................... 72

DDuplexer frequency, verify/modify ............................................................................................144

EEquipment addresses, verify ..................................................................................................... 34

Equipment configurationSave to file ........................................................................................................................ 61

Equipment featuresEnable new functionalities ................................................................................................... 34Verify ............................................................................................................................... 34

Equipment firmwareSwitch the memory benches ................................................................................................ 71Update .............................................................................................................................. 70Verify the version ............................................................................................................... 70

Equipment identifier, modify ..................................................................................................... 33

Equipment properties (type, ID, SNMP IP address, firmware version, etc.), verify ............................ 33

Equipment reference date/time, align to the PC date/time ............................................................ 34

Equipment software reset .............................................................................................. 35, 40, 73

Equipment units (type, code, version and functional status), verify ................................................ 35

Ethernet Switch

Page 182: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

180 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Address learning modality in MAC Table, verify/modify ...........................................................106Aging time of the addresses stored in the MAC Table ..............................................................106Emptying algorythm of the packets present in the output queue, verify/modify ..........................107Eth Type value in the S_Tag QinQ field, verify/modify ............................................................105Hysteresis of the LLF modality, verify/modify ........................................................................108Maximum size of the accepted packet, verify/modify ..............................................................105Output queue of a packet according to its PTOS/DSCP field, verify/assign .................................107Output queue of a packet according to its Tag 802.1p, verify/assign .........................................107Reset the MAC Table ..........................................................................................................106VLan

Create a virtual Lan ......................................................................................................109Delete a virtual Lan ......................................................................................................110Modify a virtual Lan ......................................................................................................110Verify the existing virtual LANs .......................................................................................108

GGeneration of antenna aiming signal, verify/modify ...................................................................... 94

IIP address of remote users, set ................................................................................................. 88

IP address of the agent SNMP, modify ........................................................................................ 33

LLAN 1 (optical int.)

Enable manually the laser transmission ................................................................................129Enabling status of the laser, modify .....................................................................................128Execute the test laser operating status .................................................................................129Status and configuration of the laser, verify ..........................................................................128Transmission mode of the laser, modify ................................................................................128

LAN 1, LAN 2Activation status of the autonegotiation between the roles of the line synchronism for the LAN, verify/modify .............................................................................................................................122Automatic learning of the addresses in the MAC Table for the LAN, verify/modify .......................121C-VID value of the packets in input from the LAN and forwarded to the Radio, with a different VID,verify/overwrite ................................................................................................................124Default VID value of the LAN, verify/modify ..........................................................................122Enabling status of the auto negotiation and, if the auto negotiation is inactive, the operation modalityand the transmission speed used by the LAN, verify/modify ....................................................120Enabling status of the external port, verify/modify .................................................................120Enabling status of the flow control of the LAN, verify/modify ...................................................121Enabling status of the LLF modality of the LAN, verify/modify ..................................................127Inversion status of the Tx and Rx lines of the LAN, verify/modify .............................................120List of VID registered in VLAN Table Unit and associated to the LAN, verify ...............................125Loop on line side of the LAN, activate/deactivate ...................................................................127Management of Provider Tag in the packets in input to the LAN, verify/modify ...........................124Management of the 802.1Q field on the messages in input from the LAN, verify/modify ..............123Management of the LAN in Provider mode, verify/modify ........................................................125

Page 183: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 181

Operating modality of the line synchronism (role) for the LAN, verify/modify .............................122Ports through which the messages in input from the LAN can transit, verify/modify ....................125Priority (802.1p) inside the Tag VLan of the LAN, verify/remap ................................................126Priority criterion used to associate the packets in input from the LAN to the output queue, verify/modify ....................................................................................................................126Restart the auto negotiation procedure for the LAN ................................................................121Traffic transport modality (point-point or Bridge), verify/modify ...............................................123Value for Port Default and 802.1p priority, verify/modify .........................................................126

Lan StatisticsReset the counters’ results ......................................................................................... 151, 154Verify the counters of the packets/bytes in input/output from the Ethernet ports subdivided by eachport .................................................................................................................................151Verify the summary of the main counters of the Ethernet ports ................................................154Verify/manage the main counters of the Radio port whose traffic is filtered according to C-VID identifier ..........................................................................................................................157Verify/manage the main counters of the Radio port whose traffic is filtered according to Internal Priorityvalue ...............................................................................................................................156Verify/manage the main counters of the Radio port whose traffic is filtered according to S-VID and C-VID identifiers ...................................................................................................................159

Link identification number, verify/modify .................................................................................... 92

MMAN. OP

Verify the active manual operations ...................................................................................... 29Verify/modify the manual operation timeout ........................................................................... 29

Modulation status of the RF carrier, verify/modify .......................................................................145

NNetwork address and supervision parameters of the equipment, verify/modify ................................. 39

Network password and timeout, modify ...................................................................................... 87

OOpen the WEB LCT page of an equipment (Remote Link) .............................................................. 22

Operation of the transmitter, verify/modify ................................................................................145

Operations stored into the equipment controllerDelete ............................................................................................................................... 62Save to file ........................................................................................................................ 61

PPassword and timeout of NMS5UX user, change .......................................................................... 87

Password and timeout of System user, modify ............................................................................ 86

PMActivate one or more measures ............................................................................................ 51Deactivate one or more measures ........................................................................................ 51

Page 184: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

182 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Reset the threshold exceeding alarms of one or more PM measures .......................................... 51Reset the values of the records daily and primary of one or more PM measures .......................... 51Set the thresholds of the control parameters and alarms of a PM measure ................................. 52Verify the status, the results and the threshold exceeding alarms of a PM measure ..................... 50

Port AAutomatic learning of the addresses in the MAC Table for the internal port, verify/modify ...........138Control of Tag Vlan Id on the messages in input from the internal port, verify/modify .................138C-VID value of the packets in input from the internal port and forwarded to a LAN with a different C-VID, verify/modify .............................................................................................................139Default priority, verify/modify .............................................................................................140Default VID value of the internal port, verify/modify ..............................................................139Enabling status of the flow control of the internal port, verify/modify ........................................137Enabling status of the internal port, verify/modify ..................................................................137Mapping of the priority (802.1p) inside the Tag VLan of the internal port, verify/modify ..............140Ports through which the messages in input from the internal port, verify/modify ........................139Priority criterion used to associate the packets in input from the internal port to the output queue ofthe LAN ports, verify/modify ...............................................................................................140

RRadio BER

Activate the measure .........................................................................................................170Deactivate the measure .....................................................................................................170Verify the configuration parameters of the measure ...............................................................170Verify the status of the measure ..........................................................................................170

Radio branch label, verify/modify .............................................................................................. 94

Radio loopActivate ...........................................................................................................................172Deactivate ........................................................................................................................172Verify the status ................................................................................................................172

Reference band/modulationVerify/modify ..................................................................................................................... 92

Remote equipment listAdd a station ..................................................................................................................... 24Add an equipment .............................................................................................................. 25Open the WEB page of an equipment (Remote Link) ............................................................... 26Remove a station ............................................................................................................... 24Remove an equipment ........................................................................................................ 25Rename a station ............................................................................................................... 24Reset ................................................................................................................................ 25Verify ............................................................................................................................... 23

Resolution of the received power (Prx), verify/modify ..................................................................145

Resolution of the transmitted power (Ptx), verify/modify .............................................................146

Restore Factory Default of the equipment ................................................................................... 72

Restore the access to equipment CPU ........................................................................................ 40

Retrieve the equipment configuration automatically saved by the program before the last operation of con-figuration restore (configuration revert) ..................................................................................... 78

RMonActivate the collection of the statistic counters for an Ethernet port ..........................................162Collection status of the statistic counters of the equipment Ethernet ports, verify .......................162

Page 185: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 183

Deactivate the collection of the statistic counters for an Ethernet port ......................................162Display the values of statistical counters of an Ethernet port ...................................................163

Running Default GatewayDelete ............................................................................................................................... 44Set/modify ........................................................................................................................ 44Verify ............................................................................................................................... 43

Running Routing TableAdd an element .................................................................................................................. 43Remove one or more elements ............................................................................................. 44Verify ............................................................................................................................... 43

SS/N measure

Update the value ...............................................................................................................168Verify the value .................................................................................................................168

Save the whole equipment configuration (configuration backup) .................................................... 77

SNTP functionalityActivate ............................................................................................................................ 65Deactivate ......................................................................................................................... 66Set the execution parameters .............................................................................................. 65Verify the status ................................................................................................................. 65

Stored Default GatewayDelete ............................................................................................................................... 48Set/modify ........................................................................................................................ 48Verify ............................................................................................................................... 47

Stored Routing TableAdd an element .................................................................................................................. 47Remove one or more elements ............................................................................................. 48Verify ............................................................................................................................... 47

SynchronisationEnable/disable the use of a synchronism source ..................................................................... 98Force the status of T0 synchronisation ................................................................................... 97Force the use of a synchronism source .................................................................................. 98Modify the use priority of a synchronism source ...................................................................... 98Restore the availability of a source for the selection of the T0 synchronism without waiting for the expiryof Wait Time ...................................................................................................................... 99Set a synchronism source as preferential ............................................................................... 99Set the Hold Off Time parameter .......................................................................................... 97Set the threshold levels of LTI alarm ..................................................................................... 97Set the WTR Time parameter ............................................................................................... 97Verify the status and configuration of the T0 synchronism ........................................................ 96Verify/modify the management of synchronisation .................................................................. 96

TThreshold level of the signal at reception, verify/modify ............................................................... 94

Transfer the equipment configuration previously saved (configuration restore) ................................ 77

Transmission frequency, verify/modify ......................................................................................144

Page 186: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

184 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

UUser list

Add a user ......................................................................................................................... 85Delete a user ..................................................................................................................... 86Force the logout of a user .................................................................................................... 21Modify a user ..................................................................................................................... 86Verify ............................................................................................................................... 85Verify the users connected to the equipment .......................................................................... 21

WWake Up functionality

Activate ............................................................................................................................ 66Deactivate ......................................................................................................................... 66Set the execution parameters .............................................................................................. 66Verify the status ................................................................................................................. 66

WEB LCTUpdate .............................................................................................................................. 72Verify the version ............................................................................................................... 71

WEB LCT pageClose the WEB LCT page ...................................................................................................... 16Open more WEB LCT pages .................................................................................................. 16Open the page from Browser (Ethernet connection) ................................................................ 15Open the page from SCT/LMT .............................................................................................. 15

Page 187: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 185

PARAMETERS LIST

A

Advanced Stat. Mon.1024 to Max Pkt size (Tx + Rx) Byte .......................................... 158, 1591024 to Max Pkt size (Tx) Byte ..............156128 to 255 (Tx + Rx) Byte ............ 158, 159128 to 255 (Tx) Byte ...........................156256 to 511 (Tx + Rx) Byte ............ 158, 159256 to 511 (Tx) Byte ...........................156512 to 1023 (Tx + Rx) Byte .......... 158, 159512 to 1023 (Tx) Byte ..........................15664 (Tx + Rx) Byte ....................... 158, 15964 (Tx) Byte .......................................15665 to 127 (Tx + Rx) Byte ............. 158, 15965 to 127 (Tx) Byte .............................156Byte Sent ................................... 158, 159Frame Sent ......................... 156, 157, 159Received Byte ............................. 157, 159Received Frame ..................................157Received Frames .................................159Transmitted bytes ...............................156

Agent IP Address .................................. 19, 36

Alarm ...................................................... 84

AlarmsGroup/Alarm ........................................ 83Severity .............................................. 83Trap Notification ................................... 83

ATPCATPC Regulation ..................................149ATPC Thresholds on Local PRx ...............149Max Ptx ..............................................149Tx Power Control .................................149

B

Bandwidth & Modulation ............................. 93

C

Carrier Only .............................................148

Communication stackCurrent Stack ...................................... 75

D

Default Gateway ....................................... 46

Dplx Freq ................................................148

E

Equipment Date/Time ................................ 36

Equipment Features1+0 Stand alone configuration ............... 371+1 Stand alone configuration ............... 371588 support ....................................... 37Enhanced eth monitoring ....................... 37ETH OAM ............................................. 37ETH transport ...................................... 37G8032 (eth ring protection) ................... 37OSPF .................................................. 37packet processor (1) ............................. 37packet processor (2) ............................. 37Radio payload encryptions ..................... 37Security package (+SSH + SFTP) ........... 37SSM G8264 (quality sync) ..................... 37SyncE ................................................. 37Upgrade up to 1000M ............................ 37Upgrade up to 4QAM ............................. 37Upgrade up to 750M ............................. 37

Equipment firmwareActual Release ..................................... 74Bench Status ....................................... 74Downloading Status .............................. 74Release Bench 1 ................................... 74Release Bench 2 ................................... 74Software ............................................. 74Software Version .................................. 74Unit .................................................... 74

Equipment ID ......................................19, 36

Equipment Type ...................................19, 36

Equipment unitExpected Type ..................................... 37HW Ver. .............................................. 37Par Part Num ....................................... 37Part Number ........................................ 37Real Type ............................................ 37Serial Number ...................................... 37Unit Alarms ......................................... 37

Page 188: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

186 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Ethernet IP Address ................................... 36

Ethernet IP NetMask .................................. 36

Ethernet MAC Address ............................... 36

Ethernet Switch802.1p Priority Management .................111Egress Priority Policy ............................111LLF Hysteresis .....................................112MAC Addr. Aging Time .........................111MAC Learning Vid basis ........................111Max Packet size ...................................111PTOS/DSCP

Delay ............................................112DSCP ............................................112Filter .............................................113List Filter .......................................112Precedence ....................................112QueuePri .......................................112Reliab. ..........................................112Throug. .........................................112Value ............................................112

QinQ ETH type 0x ................................111VLan

Default VLan ID ..............................113Disable ..........................................113Label ............................................113Lan1 .............................................113Lan2 .............................................113Port A ...........................................113Tagged .........................................113Unmodif. .......................................113Untag. ..........................................113VLanID .........................................113

F

Firmware Version ...................................... 36

FTP, protocol ............................................ 13

H

Help Web Server ....................................... 13

I

IP ............................................................ 75

IP/OSI Stack ............................................ 36

L

LAN 1 (optical)Laser Control

Auto Restart Time ...........................135Mode ............................................135Module Type ..................................135Test Time ......................................135Transmitter Control .........................135

LAN 1,2802.1Q

802.1q Setting ...............................132Default Vid ....................................132Lan to Radio C_Vid Rewrite ..............132Lan to Radio C_Vid Rewrite & SelectiveQinQ .............................................132Provider ........................................132Selective Provider Tag .....................132Traffic Treatment ............................132

Alarms ...............................................131Cable Crossover ..................................130Duplex ...............................................131Flow Control Full Dplx/Back Pressure Half Dplx .........................................................130

Line Loop ...........................................135LLF ....................................................134M/S Autoneg .......................................130Mac Learning ......................................131Master/Slave ......................................130Port Based VLAN .................................133Port Role ............................................131Priority

Default Priority ...............................134Priority Selection ............................134

Rate Control .......................................130Speed ................................................131Speed/Duplex .....................................131

Lan Stat.SummaryByte Received .....................................155Byte Sent ...........................................155CRC Err ..............................................155Dropped Frame (or Event) ....................155Frame Received ...................................155Frame Sent .........................................155

Lan StatisticsBroadcast Frames Received ..................152Bytes Sent ..........................................153Collisions ............................................152CRC Align Errors ..................................152Dropped Frame (or Event) ....................152Fragments ..........................................152Frames 1024 to max pck size ................153Frames 128 to 255 Oct .........................152

Page 189: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 187

Frames 256 to 511 Oct. ........................153Frames 512 to 1023 Oct .......................153Frames 64 Oct. ...................................152Frames 65 to 127 Oct. .........................152Frames Sent .......................................153In Pause Frames .................................153Jabbers ..............................................152Late Collisions .....................................153Multicast Frames Received ....................152Out Broadcast Frames ..........................153Out Multicast Frames ...........................153Out Pause Frames ...............................153Out Unicast Frames .............................153Oversize Frames .................................152Total Byte Received .............................152Total Frames Received .........................152Undersize Frame .................................152Valid Bytes Received ............................153Valid Frames Received .........................153

Local Link ID ............................................ 93

M

Measurements ResolutionPrx ....................................................148Ptx ....................................................148

O

OSI ......................................................... 75

P

Port A802.1Q

C Vid/S Vid Rewrite .........................142Default Vid ....................................142Ingress Filtering Check ....................141

Flow Control .......................................141Mac Learning ......................................141Port ...................................................141Port Based VLan ..................................142Priority

Default Priority ...............................142Priority Selection ............................142

Port ConfigurationEthernet

IP Address ...................................... 41

Net Mask ........................................ 41In Band VLan Id ................................... 41LAN 1 ................................................. 41LAN 2 ................................................. 41

R

Radio BERBER ...................................................171Elapsed Time ......................................171Errors ................................................171Fail Alarms .........................................171Sync Loss Alarm ..................................171Test Mode ..........................................171

Radio Branch Label .................................... 95

Remote Element Table ............................... 26

Remote equipment list ............................... 26

Rescue connection ..................................... 76

RMonLan Port .............................................164Status ................................................164

Routing Table ........................................... 46

Routing Table (Running) ............................. 46

Routing Table (Stored) ............................... 46

RSSI ........................................................ 95

Running Default Gateway ........................... 45Default Gateway ................................... 45

Running Routing Table ............................... 45Destination .......................................... 45Hop .................................................... 45Interface ............................................. 45Net Mask ............................................. 45Protocol .............................................. 45

Rx Signal Level Alarm Threshold .................. 95

S

S/N ........................................................169

SCT/LMT .................................................. 13

SNTPMain Server IP Address ......................... 67NTP Server Lost Alarm .......................... 67Polling Interval (Sec.) ........................... 67Polling Retries ...................................... 67Polling Timeout (Sec.) ........................... 67Reserve Server IP Addr ......................... 67

Page 190: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

188 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003

Status signal ............................................ 84

Stored Default Gateway ............................. 49Default Gateway ................................... 49

Stored Routing Table ................................. 49Destination .......................................... 49Hop .................................................... 49Interface ............................................. 49Net Mask ............................................. 49

SynchronisationAlarms ...............................................100Forced Switch .....................................101Hold Off Time .....................................100Internal ..............................................101LTI Reset Time ....................................100LTI Set Time .......................................100Name ................................................101Preferential Switch ..............................101Priority ...............................................101Status Control .....................................100Sync Drift ...........................................101Sync Loss ...........................................101Synchronisation ..................................100T2 Radio ............................................101TE LAN-1 ............................................101TE LAN-2 ............................................101WTR Time ..........................................100

T

Tx Freq ...................................................148

Tx Transmitter .........................................148

U

UserNMS5UX .............................................. 90System ............................................... 90

User list ................................................... 90Profile ................................................. 89

Read & Write .................................. 89Read Only ...................................... 89Station Op. ..................................... 89

Timeout .............................................. 89User Keep Alive .................................... 89User Name .......................................... 89

W

Wake UpGosip Address ...................................... 68NE Location ......................................... 68NMS IP Address .................................... 68Status ................................................. 67Timeout (Minutes) ................................ 68

WEB LCTCode ................................................... 75Current version .................................... 75Description .......................................... 75

WEB Lct Console ....................................... 13

WEB LCT Product Code ............................... 36

WEB LCT Version ....................................... 36

WEB LCT, release ........................................ 9

Page 191: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 189

ASSISTANCE SERVICE

For more information, refer to the section relevant to the technical support on the Internet site of the com-pany manufacturing the product.

Page 192: WEB LCT ALFOplus80alfoplus80.info/images/Documents/User-manual-Web LCT v1.2...WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003 1 WEB LCT ALFOplus80 Contents MANUAL CONTENT 9 WEB

190 WEB LCT ALFOplus80 - Release 1.2 - MN.00286.E - 003