32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938) Field complaint : Fresh defective (Dead) Reason: BD1(DIODE BRIDGE KBJ408G 4A 800V ) track cut. QP2(FET MOS TK12A60U 12A 600V TO-220F TOSHIBA)QM5,Q13,Q14 track cut. QP2 lead broken. • Corrective action : To be checked and resolder in field in case of dead. • Preventive action : PSU To be packed in individual box Note : check the PSU in cold condition before connecting in system

32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938)

Embed Size (px)

DESCRIPTION

32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938). Field complaint : Fresh defective (Dead) Reason: BD1( DIODE BRIDGE KBJ408G 4A 800V ) track cut. QP2( FET MOS TK12A60U 12A 600V TO-220F TOSHIBA)QM5,Q13,Q14 track cut . QP2 lead broken. - PowerPoint PPT Presentation

Citation preview

Page 1: 32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938)

32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938)

Field complaint : Fresh defective (Dead)

• Reason: BD1(DIODE BRIDGE KBJ408G 4A 800V ) track cut.QP2(FET MOS TK12A60U 12A 600V TO-220F TOSHIBA)QM5,Q13,Q14

track cut.QP2 lead broken.

• Corrective action : To be checked and resolder in field in case of dead.• Preventive action : PSU To be packed in individual box

Note : check the PSU in cold condition before connecting in system

Page 2: 32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938)

Field complaint : No backlight ( Audio OK)

• Reason: Protection is enable ( PT pin)

• Corrective action : remove the PT wire from connector CN3 ( pin 19 & pin 20). However this is to be done in case of problem only. It is not recommended to remove PT wire but after replacing new PSU if you observed above symtom you can remove in stray case.

32” DARFON PSU ( 1200057003 / 1200057004 / 1200054938)