14
C1.0 COVER SHEET C2.0 SCOPE OF WORK MATRIX C3.0 APPROVED VENDORS SCHEDULE C4.0 GENERAL INFORMATION C5.0 COMCHECK AS1.0 ARCHITECTURAL SPECIFICATIONS AS1.1 ARCHITECTURAL SPECIFICATIONS AS1.2 ARCHITECTURAL SPECIFICATIONS AS1.3 ARCHITECTURAL SPECIFICATIONS AS1.4 ARCHITECTURAL SPECIFICATIONS AS1.5 ARCHITECTURAL SPECIFICATIONS AS1.6 ARCHITECTURAL SPECIFICATIONS AS1.7 ARCHITECTURAL SPECIFICATIONS AS1.8 ARCHITECTURAL SPECIFICATIONS D1.0 DEMOLITION PLANS D1.0 DEMOLITION ELEVATIONS S1.0 STRUCTURAL GENERAL NOTES S2.1 FOUNDATION PLAN S2.2 ROOF FRAMING PLAN A1.0 FLOOR PLAN A2.0 FIXTURE PLAN AND FLOOR FINISHES PLAN A3.0 REFLECTED CEILING PLAN A4.0 ENLARGED PLANS A5.0 EXTERIOR ELEVATIONS A6.0 INTERIOR ELEVATIONS A6.1 INTERIOR ELEVATIONS A7.0 WALL SECTIONS A7.1 WALL SECTIONS A8.0 DETAILS A8.1 DETAILS A9.0 DOOR SCHEDULE AND DETAILS A9.1 FINISH SCHEDULE MPS1.0 MECHANICAL AND PLUMBING SPECIFICATIONS M1.0 MECHANICAL PLAN M2.0 MECHANICAL SCHEDULE AND DETAILS P1.0 PLUMBING PLAN P2.0 PLUMBING SCHEDULES AND DETAILS P2.1 PLUMBING DETAILS ES1.0 ELECTRICAL SPECIFICATIONS E1.0 POWER SYSTEMS PLAN E2.0 LIGHTING PLAN E3.0 ELECTRICAL SCHEDULES AND DETAILS E4.0 ELECTRICAL SCHEDULES, GENERAL NOTES AND DETAILS FP1.0 FIRE PROTECTION PLAN INDEX OF DRAWINGS - THE FOLLOWING PORTIONS OF THE DESIGN SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND APPROVED PRIOR TO INSTALLATION. SEPARATE PERMITS MAY BE REQUIRED -SIGNAGE -FIRE SPRINKLER MODIFICATION - ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT WITHIN 30 DAYS AFTER THE ISSUANCE OF PERMIT. - ARCHITECT OF RECORD SHALL BE RESPONSIBLE FOR COORDINATING ALL SUBMITTAL DOCUMENTS PREPARED BY OTHERS. ALL DEFERRED SUBMITTALS SHALL BE COORDINATED BY CONTRACTOR AT TIME OF PERMIT. 541 FOOTHILLS PLAZA DR. MARYVILLE, TN 37801 CONTACTS CODES BUILDING: 2012 INTERNATIONAL BUILDING CODE MECHANICAL: 2012 INTERNATIONAL MECHANICAL CODE PLUMBING: 2012 INTERNATIONAL PLUMBING CODE ELECTRIC: 2008 NEC - NFPA 70 HANDICAP: 2009 ANSI A117.1 LIFE SAFETY: 2012 NFPA 101 FIRE: 2012 INTERNATIONAL FIRE CODE ENERGY: 2012 INTERNATIONAL ENERGY CONSERVATION CODE BUILDING INFORMATION: BUILDING: EXISTING USE GROUP: M, MERCANTILE CONSTRUCTION TYPE: IIB BUILDING IS FIRE SPRINKLED EXISTING FIRE SPRINKLERS TO BE MODIFIED FOR NEW LAYOUT GROSS LEASED AREA: 8,610.5 S.F.* SALES AREA, LAVS: 8,043 S.F. @ 1 OCC/30 S.F. = 269 OCC. STOCKROOM: 567.5 S.F. @ 1 OCC/300 S.F. = 2 OCC. TOTAL OCCUPANT LOAD 271 OCC. TRAVEL DISTANCE PERMITTED: 250'-0" MAXIMUM PROVIDED: 77'-0" ACTUAL PLUMBING FIXTURE COUNT WATER CLOSETS: 1/500 = 1 REQUIRED; 1 PROVIDED MEN 1 REQUIRED; 1 PROVIDED WOMEN LAVATORIES: 1/750 = 1 REQUIRED; 1 PROVIDED MEN 1 REQUIRED; 1 PROVIDED WOMEN DRINKING FOUNTAIN: 1/1000 = 1 REQUIRED; 2 PROVIDED (HI-LO UNIT) SERVICE SINK: 1 REQUIRED; 1 PROVIDED. EXIT WIDTH REQUIRED: 0.2 INCHES 271 OCCUPANT LOAD: 54.2 INCHES PROVIDED: 100 INCHES MAIN ENTRY DOOR = 68 INCHES EGRESS DOOR = 32 INCHES (1 DOOR AT 36 INCHES) NUMBER OF EXITS REQUIRED REQUIRED: 2 PROVIDED: 2 * LEASEABLE AREA IS TO BE MEASURED PER BOMA STANDARDS (EXTERIOR FACE OF EXTERIOR WALLS AND CENTERLINE OF SHARED WALLS). DEFERRED SUBMITTALS LOCATION MAP VICINITY MAP TENANT: PET SUPPLIES PLUS 17197 N. LAUREL PARK DRIVE SUITE 402 LIVONIA, MI 48152 ARCHITECT: JOE HOCHENDONER PHONE: 734.793.6671 FAX: 734.793.6700 LANDLORD: HATCHEER-HILL PROPERTIES, LLC 311 S. WEISGARBER KNOXVILLE, TN 37919 CONTACT: PARKER BARTHOLOMEW PHONE: 865.228.9375 FAX: 865.951.7507 DESIGNER: CHIODINI ARCHITECTS 1401 S. BRENTWOOD, SUITE 425 ST. LOUIS, MISSOURI CONTACT: MICHAEL CHIODINIi PHONE: 314.725.5588 FAX: 314.725.4347 PROJECT CONSISTS OF A RENOVATION TO AN EXISTING STORE FOR A NEW PET SUPPLIES RETAIL STORE INCLUDING PET GROOMING SERVICES. WORK INCLUDES: INTERIOR WALLS, CEILING, FINISHES INTERIOR DOORS PLUMBING HVAC ELECTRICAL POWER AND LIGHTING RETAIL DISPLAY FIXTURES AND RACKING SCOPE OF WORK CONSTRUCTION CONTACT: SHAUN MACLELLAN PHONE: 440.829.9139 REVISIONS SHEETS DESCRIPTION REVISION DATE 1 2 3 5 B A JOB NO. D C ISSUED FOR: PERMIT RELEASE CONSTRUCTION BID 2015-052 PET SUPPLIES PLUS FOOTHILLS PLAZA 541 FOOTHILLS PLAZA DR. - - 12.04.15 - MARYVILLE, TN 37801 REV. DATE DESCRIPTION DESIGNER PROJECT MANAGER Drawing Name: X:\2015.052 PSP- Maryville, TN (franchisee)\CAD\2015.052_C1.0.dwg December 4, 2015 - walbrecht C1.0 COVER SHEET SBE SBE PROJECT SITE PROJECT SITE

2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

C1.0 COVER SHEET

C2.0 SCOPE OF WORK MATRIX

C3.0 APPROVED VENDORS SCHEDULE

C4.0 GENERAL INFORMATION

C5.0 COMCHECK

AS1.0 ARCHITECTURAL SPECIFICATIONS

AS1.1 ARCHITECTURAL SPECIFICATIONS

AS1.2 ARCHITECTURAL SPECIFICATIONS

AS1.3 ARCHITECTURAL SPECIFICATIONS

AS1.4 ARCHITECTURAL SPECIFICATIONS

AS1.5 ARCHITECTURAL SPECIFICATIONS

AS1.6 ARCHITECTURAL SPECIFICATIONS

AS1.7 ARCHITECTURAL SPECIFICATIONS

AS1.8 ARCHITECTURAL SPECIFICATIONS

D1.0 DEMOLITION PLANS

D1.0 DEMOLITION ELEVATIONS

S1.0 STRUCTURAL GENERAL NOTES

S2.1 FOUNDATION PLAN

S2.2 ROOF FRAMING PLAN

A1.0 FLOOR PLAN

A2.0 FIXTURE PLAN AND FLOOR FINISHES PLAN

A3.0 REFLECTED CEILING PLAN

A4.0 ENLARGED PLANS

A5.0 EXTERIOR ELEVATIONS

A6.0 INTERIOR ELEVATIONS

A6.1 INTERIOR ELEVATIONS

A7.0 WALL SECTIONS

A7.1 WALL SECTIONS

A8.0 DETAILS

A8.1 DETAILS

A9.0 DOOR SCHEDULE AND DETAILS

A9.1 FINISH SCHEDULE

MPS1.0 MECHANICAL AND PLUMBING SPECIFICATIONS

M1.0 MECHANICAL PLAN

M2.0 MECHANICAL SCHEDULE AND DETAILS

P1.0 PLUMBING PLAN

P2.0 PLUMBING SCHEDULES AND DETAILS

P2.1 PLUMBING DETAILS

ES1.0 ELECTRICAL SPECIFICATIONS

E1.0 POWER SYSTEMS PLAN

E2.0 LIGHTING PLAN

E3.0 ELECTRICAL SCHEDULES AND DETAILS

E4.0 ELECTRICAL SCHEDULES, GENERAL NOTES AND DETAILS

FP1.0 FIRE PROTECTION PLAN

INDEX OF DRAWINGS

- THE FOLLOWING PORTIONS OF THE DESIGN SHALL BE SUBMITTED TO THE

BUILDING DEPARTMENT AND APPROVED PRIOR TO INSTALLATION. SEPARATE

PERMITS MAY BE REQUIRED

-SIGNAGE

-FIRE SPRINKLER MODIFICATION

- ALL DEFERRED SUBMITTALS SHALL BE SUBMITTED TO THE BUILDING

DEPARTMENT WITHIN 30 DAYS AFTER THE

ISSUANCE OF PERMIT.

- ARCHITECT OF RECORD SHALL BE RESPONSIBLE FOR COORDINATING ALL

SUBMITTAL DOCUMENTS PREPARED BY OTHERS. ALL DEFERRED SUBMITTALS

SHALL BE COORDINATED BY CONTRACTOR AT TIME OF PERMIT.

541 FOOTHILLS PLAZA DR.

MARYVILLE, TN 37801

CONTACTS

CODES

BUILDING: 2012 INTERNATIONAL BUILDING CODE

MECHANICAL: 2012 INTERNATIONAL MECHANICAL CODE

PLUMBING: 2012 INTERNATIONAL PLUMBING CODE

ELECTRIC: 2008 NEC - NFPA 70

HANDICAP: 2009 ANSI A117.1

LIFE SAFETY: 2012 NFPA 101

FIRE: 2012 INTERNATIONAL FIRE CODE

ENERGY: 2012 INTERNATIONAL ENERGY CONSERVATION CODE

BUILDING INFORMATION:

BUILDING: EXISTING

USE GROUP: M, MERCANTILE

CONSTRUCTION TYPE: IIB

BUILDING IS FIRE SPRINKLED

EXISTING FIRE SPRINKLERS TO BE MODIFIED FOR NEW LAYOUT

GROSS LEASED AREA: 8,610.5 S.F.*

SALES AREA, LAVS: 8,043 S.F. @ 1 OCC/30 S.F. = 269 OCC.

STOCKROOM: 567.5 S.F. @ 1 OCC/300 S.F. = 2 OCC.

TOTAL OCCUPANT LOAD 271 OCC.

TRAVEL DISTANCE

PERMITTED: 250'-0" MAXIMUM

PROVIDED: 77'-0" ACTUAL

PLUMBING FIXTURE COUNT

WATER CLOSETS: 1/500 = 1 REQUIRED; 1 PROVIDED MEN

1 REQUIRED; 1 PROVIDED WOMEN

LAVATORIES: 1/750 = 1 REQUIRED; 1 PROVIDED MEN

1 REQUIRED; 1 PROVIDED WOMEN

DRINKING FOUNTAIN: 1/1000 = 1 REQUIRED; 2 PROVIDED (HI-LO UNIT)

SERVICE SINK: 1 REQUIRED; 1 PROVIDED.

EXIT WIDTH REQUIRED:

0.2 INCHES 271 OCCUPANT LOAD: 54.2 INCHES

PROVIDED: 100 INCHES

MAIN ENTRY DOOR = 68 INCHES

EGRESS DOOR = 32 INCHES (1 DOOR AT 36 INCHES)

NUMBER OF EXITS REQUIRED

REQUIRED: 2

PROVIDED: 2

* LEASEABLE AREA IS TO BE MEASURED PER BOMA STANDARDS (EXTERIOR FACE

OF EXTERIOR WALLS AND CENTERLINE OF SHARED WALLS).

DEFERRED SUBMITTALS

LOCATION MAP

VICINITY MAP

TENANT:

PET SUPPLIES PLUS

17197 N. LAUREL PARK DRIVE

SUITE 402

LIVONIA, MI 48152

ARCHITECT: JOE HOCHENDONER

PHONE: 734.793.6671

FAX: 734.793.6700

LANDLORD:

HATCHEER-HILL PROPERTIES, LLC

311 S. WEISGARBER

KNOXVILLE, TN 37919

CONTACT: PARKER BARTHOLOMEW

PHONE: 865.228.9375

FAX: 865.951.7507

DESIGNER:

CHIODINI ARCHITECTS

1401 S. BRENTWOOD, SUITE 425

ST. LOUIS, MISSOURI

CONTACT: MICHAEL CHIODINIi

PHONE: 314.725.5588

FAX: 314.725.4347

PROJECT CONSISTS OF A RENOVATION TO AN EXISTING STORE FOR A NEW PET

SUPPLIES RETAIL STORE INCLUDING PET GROOMING SERVICES.

WORK INCLUDES:

INTERIOR WALLS, CEILING, FINISHES

INTERIOR DOORS

PLUMBING

HVAC

ELECTRICAL POWER AND LIGHTING

RETAIL DISPLAY FIXTURES AND RACKING

SCOPE OF WORK

CONSTRUCTION CONTACT:

SHAUN MACLELLAN

PHONE: 440.829.9139

REVISIONS

SHEETSDESCRIPTIONREVISION DATE

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_C

1.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

C1.0

CO

VE

R S

HE

ET

SBE SBE

PROJECT SITE

PROJECT SITE

AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
4
Page 2: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

FU

RN

IS

HE

D /

PU

RC

HA

SE

D B

Y:

IN

ST

AL

LE

D B

Y:

DIVISION OF WORK: (TURNKEY DEAL)

ALL WORK SHOWN ON THE PLANS TO BE COMPLETE BY THE LANDLORD AT THE LANDLORD'S EXPENSE UNLESS NOTED

OTHERWISE.

PS

P

LA

ND

LO

RD

PS

P

LA

ND

LO

RD

CONSTRUCTION DOCUMENTS

TEMPORARY UTILITIES

UTILITY FEES (DURING CONSTRUCTION)

WASTE CONTAINER/HAULING

PROJECT TYPE: PET SUPPLIES PLUS BUILD-OUT

EX

IS

T. / N

OT

A

PP

LIC

AB

LE

GENERAL REQUIREMENTS0 1 2 3 4

PERMITS/APPROVAL

CERTIFICATE OF OCCUPANCY

EXTERIOR / SITE WORK

PARKING LOT LIGHTING - GOOD WORKING CONDITION

ROOF - WATERTIGHT, GOOD CONDITION

MECHANICAL

ROOF PENETRATIONS, STRUCTURAL SUPPORT, CURBING,

FLASHING (IF APPLICABLE)

HVAC UNITS

HVAC DISTRIBUTION (DUCTWORK/DIFFUSERS)

THERMOSTATS & CONTROL WIRE

EXHAUST FANS AND DISTRIBUTION

SPRINKLER MODIFICATIONS (TENANT SPECIFIC DESIGN)

FIRE EXTINGUISHERS AND TAGS / SIGNS

PLUMBING

1 1/2" WATER SERVICE INTO TENANT SPACE

TOILET ROOM FIXTURES

4" SANITARY

UTILITY SINK/WATER HEATER

CARPENTRY

DEMISING WALL STRUCTURE

DEMISING WALLS (GYPSUM BOARD, TENANT SIDE)

MILLWORK CABINETRY

COUNTER TOPS / SHELVING

MISC. WOOD BLOCKING, FURRING, ETC.

TOILET ROOM ACCESSORIES

DOORS AND HARDWARE

AUTOMATIC STOREFRONT ENTRANCE DOORS

REAR SERVICE DOORS / OVERHEAD STOCK DOOR

INTERIOR DOORS, FRAMES

FINISHES

PAINT

FLOOR FINISH

VINYL BASE

CERAMIC TILE (FLOORS/WALLS)

FRP PANELS

CEILING ( 2 x 4 LAY-IN )

ALL PIPING, FITTINGS, VENTS, ETC.

SPRINKLER SYSTEM (MAIN/BRANCHES/HEADS)

FINAL CONNECTIONS

AUTOMATIC INTERIOR VESTIBULE DOORS

REQUIRED EXTERIOR EGRESS EXIT DOOR(S)

INTERIOR PARTITIONS (STUDS / DRYWALL )

FIXTURE PLAN

2x4 BLOCKING AROUND SALES FLOOR PERIMETER

SLAB MOISTURE TEST / SLAB LEVELING

GAS PIPING TO ROOF TOP UNITS (IF APPLICABLE)

SERVICE AND START-UP HVAC UNITS

FU

RN

IS

HE

D /

PU

RC

HA

SE

D B

Y:

PS

P

EX

IS

T. / N

OT

A

PP

LIC

AB

LE

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

0 1 2 3 4

ELECTRICAL0 1 2 3 4

PANELS / METERS

INCOMING SERVICE TO LOCATION SHOWN ON TENANT PLANS

DISTRIB. BOXES, CABLES, POWER POLES

SCISSOR LIFT (IF APPLICABLE)

TEMPORARY LIGHTING

ADA CURB RAMP(S) - NEW IF NEEDED, OR EXIST. IN GOOD CONDITION

EXTERIOR BOLLARDS

CONCRETE SCISSOR LIFT PAD (IF APPLICABLE)

EXTERIOR, BUILDING MOUNTED LIGHTING

NOTES

TENANT IMPROVEMENTS

DURING CONSTRUCTION ONLY

AT NEW EGRESS DOORS AND OVERHEAD DOORS

NOTES

RECTANGULAR DUCTWORK WITH INSULATION WRAP AT ALL CONCEALED AREAS

(ABOVE CEILINGS)

NOTES

INCLUDING ALL REQUIRED METERING, BACKFLOW AND VALVES

SUB-METERING

INCLUDING ALL REQUIRED BACKFLOW AND VALVES

CONTRACTOR TO VERIFY EXACT LOCATION, SIZE, DEPTH & FLOW DIRECTION

PRIOR TO START OF WORK

GAS SERVICE AND METER

INTERIOR DISTRIBUTION & FINAL CONNECTION

JUNCTION BOXES

INTERIOR LIGHTING

EXIT AND EMERGENCY LIGHTING

TELEPHONE CONDUIT / PHONE BOARD

REGISTER P.O.S. - EQUIPMENT AND FINAL CONNECTIONS

FIRE ALARM SYSTEM - MODIFICATIONS (IF APPLICABLE)

LOW VOLTAGE (VOICE, DATA, MUSIC) CONDUIT AND WIRE

CASH WRAP POWER POLE(S)

NOTES

1" TELEPHONE CONDUIT WITH PULL WIRE STUBBED INTO TENANT SPACE FROM

MASTER TELEPHONE PANEL

INCLUDING ADDITIONAL DEVICES AS REQUIRED

FLOORS0 1 2 3 4 NOTES

INTERIOR CONCRETE SLAB - MEP ROUGH-INPROVIDE FLOOR SLAB AT PLUMBING LEAVE-OUT AREAS (MINIMUM 3000 PSI)

FLOW TAMPER SWITCHES, HEADS TURNED UP TO ROOF STRUCTURE. MODIFY

SPRINKLER SYSTEM (MAIN LINES, BRANCH LINES, HEADS, TAMPER SWITCHES,

ETC.) TO SUIT PSP'S LAYOUT. ALL MAIN & BRANCH LINES ARE NOT TO BE LOWER

THAN 16'-0" A.F.F.

LEVEL 4 FINISH, PROVIDE FIRE ASSEMBLY RATING REQUIRED FOR PET SUPPLIES

PLUS USE & OCCUPANCY. AT EXTERIOR DEMISING LOCATIONS PROVIDE

THERMAL INSULATION, VAPOR BARRIER , ETC. AS REQUIRED BY CODE.

LEVEL 4 FINISH

THRU WALL PENATRATIONS AND HEAD OF WALL SEALANTS REQUIRED

BY FIRE SEPARATION ASSEMBLY

ALL PENETRATIONS

SOUND ATTENUATION INSULATION

PS

P G

C

PS

P G

C

5 6

5 6

5 6

5 6

5 6

LA

ND

LO

RD

PS

P

LA

ND

LO

RD

PS

P G

C

PS

P G

C

5 6

IN

ST

AL

LE

D B

Y:

5 6

5 6

5 6

ENVIRONMENTAL, ASBESTOS AND MOLD TESTING WITH ABATEMENT

REPORT FOR THE PREMISES

CLEAN UP

DEMOLITION

PROVIDE A SLOPED RAMP FROM SIDEWALK TO PARKING SURFACE COMPLYING

WITH ALL GOVERNING ACCESSIBILITY REQUIREMENTS

ALL PENETRATION LOCATIONS & SIZES AS INDICATED ON DRAWINGS. PROVIDE

STRUCTURAL SUPPORT, ROUT PENETRATIONS, INSULATED CURBS & FLASHING

RECTANGULAR DUCTWORK WITH INSULATION WRAP AT ALL CONCEALED AREAS

(ABOVE CEILINGS)

HVAC DISTRIBUTION TO GROOMING, PUBLIC PET WASH AND SERVICE

ROOMS (DUCTWORK/DIFFUSERS)

MODIFY TO SUIT PSP'S LAYOUT. ALL MAIN & BRANCH LINES ARE NOT TO BE

LOWER THAN 16'-0" A.F.F.

PROVIDE CERTIFIED AIR BALANCE LETTER

DRINKING FOUNTAINS

FIRE ALARM SYSTEM - CONDUIT AND CONNECTION STUBBED TO

TENANT SPACE

FIRE ALARM SYSTEM - TENANT DEVICES, FINAL CONNECTION TO

LANDLORDS SYS. OR INDEPENDENT SYS. BASED ON SITE SPECIFIC

APPLICATION

CONCRETE SIDEWALKS

GOOD CONDITION, REPAIR AS NEEDED

DUMPSTER PAD ENCLOSURE AS REQ. BY LOCAL JURISDICTIONS & IN CLOSE PROXIMITY TO TENANTS SPACE.

MINIMUM 25'Wx12'Dx7'H TRASH ENCLOSURE & SPACE INSIDE THE ENCLOSURE

FOR AN 8 YARD DUMPSTER, 8 YARD CARD BOARD RECYCLE BIN & WHEELED

TOTES FOR PLASTIC RECYCLING.

STOREFRONT FACADEPATCH, REPAIR, MODIFY AS NEEDED, PROVIDED NEW, ETC.

EXISTING RECESSED OR RAISED DELIVERY DOCK

IF EXISTING DELIVERY DOCK IS TO BE REUSED, PROVIDE WORK AS

OUTLINED IN THESE CONSTRUCTION DOCUMENTS.

CONCRETE PAD IN FRONT OF OVERHEAD DOOR

FROST SLAB

LOADING AREA

LANDLORD TO PROVIDE SITE AREA & NECESSARY CONSTRUCTION TO ALLOW

FOR TENANTS TRACTOR TRAILER TO ACCESS THE LOADING DELIVERY AREA

EXTERIOR WALLS

PROVIDE AT LOW PRESSING /7" W.C. & 900 TO 1100 MBH STUBBED TO TENANT

SPACE

REFER TO OFFICE PLANS FOR ADDITIONAL INFORMATION

2" EMT POWER POLE AT CASH WRAPS (RAW STEEL)

INTERIOR CONCRETE SLAB - LEVELING

PROVIDE SMOOTH, UNIFORM, LEVEL FLOOR READY FOR TENANT'S FINISHES.

FLOOR LEVELING AGENT TO BE COMPATIBLE WITH TENANT'S FLOOR FINISH.

(MINIMUM 3000 PSI)

STOREFRONT GLAZING AND FRAMESPROVIDE THERMAL BROKEN ALUMINUM FRAME WITH 1" INSULATED GLAZING,

TEMPERED. EXISTING STOREFRONT MAY BE REUSED IF IT COMPLIES WITH ALL

GOVERNING CODES & IS APPROVED BY PET SUPPLIES PLUS. IF EXISTING IS

REUSED, REPAIR AND CLEAN AS REQUIRED FOR LIKE NEW CONDITION.

LEVEL 4 FINISH, PROVIDE FIRE ASSEMBLY RATING REQUIRED FOR PET SUPPLIES

PLUS USE & OCCUPANCY. AT EXTERIOR DEMISING LOCATIONS PROVIDE

THERMAL INSULATION, VAPOR BARRIER , ETC. AS REQUIRED BY CODE.

PROVIDE FULL HEIGHT OF WALL WITH STC RATING OF 50 OR BETTER

VESTIBULE

PROVIDE COMPLETE VESTIBULE STOREFRONT SYSTEM WITH GYPSUM

BOARD & METAL STUD WALL ABOVE ON ALL SIDES OF VESTIBULE TO

UNDERSIDE OF ROOF DECK.

FURRED PARTITION ALONG DEMISING WALL

FURRED OUT DEMISING WALL TO CREATE A CONTINUOUS FLUSH WALL FROM

FINISH FLOOR TO UNDERSIDE OF DECK FOR THE ENTIRE WALL LENGTH

NOTES

TENANT'S SHELL SPACE (FLOOR, WALLS, ROOF, ETC) ENERGY

COMPLIANCE

PROVIDE TENANT'S SHELL IN COMPLIANCE WITH ALL GOVERNING ENERGY

CODES.

PROVIDE CONCRETE PAD AT NEW SCISSOR LIFT LOCATION. SLOPE PAD SO

WATER DRAINS AWAY FROM BUILDING. PROVIDE ALL NECESSARY

CONCRETE PAD EDGE CONDITIONS PER SITE SPECIFIC REQUIREMENTS.

PROVIDE CONCRETE PAD AT NEW OVERHEAD DOOR LOCATION. (MINIMUM OF

12'x12') SLOPE PAD SO WATER DRAINS AWAY FROM THE BUILDING. PROVIDE

ALL NECESSARY CONCRETE PAD EDGE CONDITIONS PER SITE SPECIFIC

REQUIREMENTS.

NOTES

NOTES

NOTES

LANDLORD SHALL PAY THE COST FOR ALL TAP, IMPACT USAGE,

CONNECTION & OTHER SIMILAR FEES REQUIRED FOR TENANT'S USE &

OCCUPANCY OF THE PREMISES.

TO BE PURCHASED THRU PSP's NATIONAL VENDOR.

APPROVED VENDOR PRE-WIRES DURING THE CONSTRUCTION PHASE.

OFFICE, GROOMING AND ISOLATION ROOM.

ALSO REFER TO "TENANT/VENDOR SUPPLIED ITEMS RESPONSIBILITY SCHEDULE"

FOR ADDITIONAL INFORMATION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_C

2.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

C2.0

SC

OP

E O

F W

OR

K

MA

TR

IX

DISCLAIMER:

THE INFORMATION CONTAINED IN THIS MATRIX IS A NON BINDING

INTERPRETATION OF A LIMITED SET OF DOCUMENTS PROVIDED TO THE

ARCHITECT BY OTHERS AND PREPARED BY OTHERS. THIS MATRIX SHALL NOT

TO BE USED TO ALTER IN ANY WAY THE TENANT'S LEASE OR THE CONTRACTS

BETWEEN THE TENANT, LANDLORD, PET SUPPLIES PLUS AND ANY

CONTRACTOR FOR THE LANDLORD, TENANT OR PET SUPPLIES PLUS.

AutoCAD SHX Text
4
Page 3: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

PET SUPPLIES PLUS APPROVED VENDORS

1. SOUND SYSTEM

MOOD-MUSAK

JASON TORRES

PHONE: (512) 380-8544

EMAIL: [email protected]

2. INTERIOR DECOR

DESIGN FABRICATIONS

32400 INDUSTRIAL DRIVE

MADISON HEIGHTS, MI 48071

MATT HARVELL

PHONE: (800) 968-9440

EMAIL: [email protected]

3. INTERIOR DECOR INSTALL

ENGELKE CONSTRUCTION

BRAD DETWILER

or SCOTT SHYMSKE

PHONE: (330) 273-2222

EMAIL: [email protected]

EMAIL: [email protected]

4. PHONE & DATA

CENTRAL COM

5401 HEARTNECK

VALLEY CITY, OH 44280

LARRY RUSSELL

PHONE: (330) 220-0802

CELL: (216) 323-5248

EMAIL: [email protected]

HARMON SIGN

46593 GRAND RIVER AVE.

NOVI, MI 48374

NICOLE STARKEY

PHONE: (248) 348-8150 x200

EMAIL: [email protected]

GROOMERS CHOICE PET PRODUCTS

1501 N. INDUSTRIAL AVE.

SIOUX FALLS, SD 57104

RAYAN OAKS

PHONE: (605) 782-0500

EMAIL: [email protected]

15. AQUARIUM FIXTURES

MARINELAND RETAILER SYSTEMS

6144 CONDOR DR.

MOON PARK, CA 93021

PONCH ZIZUMBO

PHONE: (805) 222-3605

FAX: (805) 517-7142

EMAIL: [email protected]

16. DISPLAY FIXTURES

LOZIER FIXTURES

JOE BENADUM

PHONE: (614) 793-1962

EMAIL: [email protected]

5. EXTERIOR SIGNAGE

EVERBRITE, LLC

4949 S. 110TH ST.

GREENFIELD, WI 53228

JOHN PORTER

PHONE: (414) 529-7163

EMAIL: [email protected]

6. PET GROOMING/PPW EQUIPMENT

B-AIR DRYERS (INTEREX INC.)

550 S. AYON AVE.

AZUSA, CA 90702

JOHNSON TAN

PHONE: (626) 385-3300 x205

EMAIL: [email protected]

-OR-

7. LIGHT FIXTURES

LEFF ELECTRIC

4700 SPRING ROAD

CLEVELAND, OH 44131

STEVE LIAS

PHONE: (216) 432-3000

EMAIL: [email protected]

8. LOCKSMITH

BASS SECURITY SERVICES, INC.

GENEO OBERST

GIRTMAN & ASSOCIATES

PHONE: (888) 774-3400 x1193

EMAIL: [email protected]

9. SECURITY SYSTEM

PROTECTION ONE

MIKE BRADFORD

PHONE: (412) 913-9185

11. SCISSOR LIFT OR TOW MOTER

TOYOTA MATERIAL HANDLING

5667 EAST SCHAAF ROAD

CLEVELAND, OH 44131

ED BOROWY

PHONE: (800) 722-1211

EMAIL: [email protected]

12. POS SYSTEM

RETALIX INC.

797 COMMONWALTH DR.

WARRENDALE, PA 15086

BOB SCHMITT

PHONE: (724) 612-3409

EMAIL: [email protected]

13. CART CORAL

GROUP 4 RETAIL EQUIPMENT

DORIE GUNDERSON

PHONE: (800) 326-2460

EMAIL: [email protected]

17.

18. FLOORING EPOXY/STAINED CONCRETE

ELITE COATINGS LLC

TONY WOJTON

PHONE: (330) 741-3003

CELL: (440) 212-2430

EMAIL: [email protected]

-OR-

INTERIOR LIGHT FIXTURES AND LAMPS LIGHTING PACKAGE ORDERED BY LANDLORD FROM ELECTRICAL VENDOR AND PAID FOR BY LANDLORD

EXIT & EMERGENCY LIGHTING LIGHTING PACKAGE ORDERED BY LANDLORD FROM ELECTRICAL VENDOR AND PAID FOR BY LANDLORD

TENANT / VENDOR SUPPLIED ITEMS RESPONSIBILITY SCHEDULE

(TURNKEY DEAL)

FU

RN

IS

HE

D /

PU

RC

HA

SE

D B

Y:

IN

ST

AL

LE

D B

Y:

PS

P

PS

P G

.C

.

PS

P

PS

P G

.C

.

PE

T S

UP

PLIE

S P

LU

S

AP

PR

OV

ED

V

EN

DO

R

14

MISC. LABOR

GC TO PROVIDE 8 HOURS OF MISC. LABOR AFTER TURN OVER TO PSP FOR FIXTURE SET-UP AND

MERCHANDISING.

ITEMS OF CONSTRUCTION NOTES

WALL BUMPERS & CORNER GUARDS

13CART CORRAL

5 EXTERIOR SIGNAGE

GC TO PROVIDE POWER CIRCUIT & SHALL MAKE FINAL ELECTRICAL CONNECTION, COORDINATE ROUGH-IN LOCATION REQUIREMENTS & TIMELY INSTALLATION WITH SIGN

VENDOR. POWER TO BE PROVIDED WITHIN 5'-0" OF SIGN POWER BOXES. GC & SIGN VENDOR TO HAVE SITE MEETING TO COORDINATE PRIOR TO SIGN INSTALLATION.

2, 3INTERIOR SIGNAGE

2, 3INTERIOR DECOR

6PET WASH TUBS GC SHALL SET AND SECURE TUBS TO FLOOR. MAKE FINAL PLUMBING CONNECTIONS.

6FORCED AIR DRYERS

16 SALES FLOOR DISPLAY FIXTURES

GC SHALL INSTALL SURFACE MOUNTED 2x4 FIRE RETARDANT BLOCKING ON PERIMETER WALLS FOR DISPLAY FIXTURE ATTACHMENT. REFER TO INTERIOR

ELEVATIONS.

16STOCKROOM STORAGE FIXTURES

15AQUARIUM FIXTURES

GC TO MAKE ALL FINAL ELECTRICAL CONNECTIONS. GC TO PROVIDE ALL PLUMBING PER VENDORS REQUIREMENTS. AQUARIUM FIXTURES SCHEDULED FOR DELIVERY

AFTER TURN OVER TO PSP FOR FIXTURE SET-UP AND MERCHANDISING.

2, 3 INTERIOR RETAIL SIGNAGE

7

7

7CASH-WRAP POWER POLES ORDERED BY GC FROM ELECTRICAL VENDOR AND PAID FOR BY GC.

TELEPHONE & DATA WIRING TO SPACE

TELEPHONE & DATA WIRING WITHIN SPACE GC TO PROVIDE CONDUIT WITH PULL WIRE PER OFFICE PLAN. REFER TO ELECTRICAL DRAWINGS.

TELEPHONE AND DATA JACK TERMINATIONS

TELEPHONE EQUIPMENT

12POS SYSTEM HARDWARE

12

POS SYSTEM WIRING GC TO PROVIDE CONDUIT WITH PULL WIRE PER OFFICE PLAN. REFER TO ELECTRICAL DRAWINGS.

12POS SYSTEM JACK TERMINATIONS

9SECURITY SYSTEM WIRING

9SECURITY SYSTEM DEVICES

1

MUSIC SOUND SYSTEM HARDWARE

1MUSIC SOUNDSYSTEM WIRING

1

MUSIC SOUND SYSTEM SPEAKERS

16CASH WRAPS

MILLWORK

CASH WRAP POWER, VOICE, AND DATA

DOOR LOCKS & KEYS8

GC SHALL SECURE CASH WRAPS TO FLOOR

ALL MILLWORK (BESIDES CASH WRAPS & MILLWORK GROOMING STATION) IS THE GC'S RESPONSIBILITY

GC TO MAKE ALL FINAL CONNECTIONS.

GC SHALL SET AND SECURE DRYER TO SHELF. MAKE FINAL PLUMBING & ELECTRICAL CONNECTIONS.

LA

ND

LO

RD

G

.C

.

LA

ND

LO

RD

G

.C

.

MILLWORK GROOMING STATION

BATH MASTER SOAP SYSTEM6

11SCISSOR LIFT

14. WALL BUMPER/CORNER GUARDS

IMPACT SPECIALTIES

JEN MACCARTHY

PHONE: (888) 424-6287

FAX: (908) 849-4295

EMAIL: [email protected]

10. STOREFRONT DOORS

RECORD AUTOMATIC DOOR SYSTEMS

(RECORD-USA)

NICHOLE McCOLLUM (POINT OF CONTACT)

PHONE: 704-289-2024

FAX: 704-289-2024

EMAIL: NICHOLE.MCCOLUUM@RECORD-

USA.COM

DON HUNTER (ESTIMATOR)

PHONE: 704-290-0217

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_C

3.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

C3.0

AP

PR

OV

ED

V

EN

DO

RS

SC

HE

DU

LE

GPD GPD

DISCLAIMER:

THE INFORMATION CONTAINED IN THIS SCHEDULE IS A NON BINDING

INTERPRETATION OF A LIMITED SET OF DOCUMENTS PROVIDED TO THE

ARCHITECT BY OTHERS AND PREPARED BY OTHERS. THIS SCHEDULE SHALL

NOT TO BE USED TO ALTER IN ANY WAY THE TENANT'S LEASE OR THE

CONTRACTS BETWEEN THE TENANT, LANDLORD, PET SUPPLIES PLUS AND

ANY CONTRACTOR FOR THE LANDLORD, TENANT OR PET SUPPLIES PLUS.

19. FIRE ALARM

PROTECTION ONE

MIKE BRADFORD

PHONE: (412) 913-9185

michael [email protected]

19

FIRE ALARM

FOR PSP'S TENANT BUILD OUT CONNECT TO LANDLORD'S EXISTING FIRE ALARM SYSTEM OR PROVIDE AN INDEPENDENT FIRE ALARM SYSTEM AS REQUIRED. COORDINATE

WITH LANDLORD AND PSP VENDOR.

AutoCAD SHX Text
4
Page 4: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

1. BASED ON INTERIOR NONBEARING PARTITIONS WITH ONE LAYER OF GYPSUM

BOARD EACH SIDE; USE GAUGE, TYPE AS SCHEDULED UNLESS NOTED

OTHERWISE ON DRAWINGS.

2. RUNNER TRACK GAUGE TO MATCH STUD.

3. ALL WALLS SHALL HAVE 1-1/2" X16 GA, COLD ROLLED CHANNEL HORIZONTAL

BRIDGING SPACED AT 6'-0".

MAX. UNSUPPORTED HT

SIZE GA. TYPE

16" O.C. 24" O.C.

NOTES 1,2,3

3 5/8"20 15'-5" 13'-5"

19'-1"18

18 28'-4"

20'-3"23'-2"20

6"

16'-8"

24'-9"

SECTION TAG:

INTERIOR

ELEVATION TAG

FINISH FLOOR

0'-0" A.F.F.

25 CSJ12'-7" 11'-0"

NOTES:

CSJ

CSJ

CSJ

CSJ

ROOM NAME

00/A0.0

#

#

00

X0.0

00

A0.0

DETAIL TAG:

DOOR TAG:

SHEET NOTE:

FINISH TAG:

ROOM TAG:

PARTITION TYPE:

F

DATUM TAG:

SYMBOLS LEGENDINTERIOR METAL STUD SCHEDULE

XX-0

ACCESSIBILITY STANDARDS

SIGNAGE SHOULD COMPLY W/ RELEVANT GUIDELINES AS FOLLOWS.

A. ALL PERMANENT ROOM AND SPACE IDENTIFICATION SIGNAGE SHALL COMPLY

WITH SECTIONS 1 THROUGH 5.

B. ALL DIRECTIONAL AND INFORMATIONAL SIGNAGE SHALL COMPLY

WITH SECTIONS 1 & 2.

C. ALL IDENTIFICATION, INFORMATIONAL OR DIRECTIONAL SIGNAGE ABOUT

ACCESSIBLE ELEMENTS AND FEATURES SHALL COMPLY WITH SECTIONS 1

THROUGH 5.

SIGNAGE DESIGN CRITERIA:

1. FINISH AND CONTRAST:

CHARACTER, SYMBOLS, BACKGROUNDS SHALL HAVE A NON-GLARE FINISH.

CHARACTER & SYMBOLS SHALL CONTRAST A MIN. OF 70% W/ THEIR

BACKGROUND.

LRV FINISH (LIGHT REFLECTANCE VALUE) OF MATERIAL FINISHES SHALL BE

ASTM E1349-90 OR EQUAL.

2. PROPORTIONS:

CHARACTERS ARE TO HAVE A WIDTH-TO-HEIGHT RATIO OF 3:5 TO 1:1.

CHARACTER STROKE WIDTH-TO-HEIGHT OF 1:5 TO 1:10.

3. RAISED CHARACTERS AND PICTORAL SIGN SYMBOLS:

CHARACTER TYPE:

1/32" RAISED (MIN.)

SANS SERIF UPPERCASE WITH GRADE 2 BRAILLE.

CHARACTER SIZE:

MIN.5/8" AND MAX. 2" HIGH

PICTOGRAMS:

ACCOMPANY W/ VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE

PICTOGRAM.

OUTSIDE DIMENSION OF PICTOGRAM FIELD TO BE MIN. 6" HEIGHT.

CHARACTER PLACEMENT:

CHARACTERS AND BRAILLE SHALL BE IN HORIZONTAL FORMAT

BRAILLE SHALL BE PLACED 3/8" (MIN.) & 1/2" (MAX.) DIRECTLY BELOW THE

TACTILE CHARACTERS (FLUSH LEFT OR CENTER).

IF TACTILE TEXT IS MULTILINE, ALL BRAILLE SHALL BE PLACED

TOGETHER BELOW ALL LINES OF TACTILE TEXT.

4. BRAILLE:

CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER APPLICABLE

STANDARDS REQUIRE BRAILLE.

DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL W/ 2/10" SPACE BETWEEN

CELLS, MEASURED FROM THE SECOND COLUNMN OF DOTS IN THE FERST

CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL.

DOTS SHALL BE RAISED A 1/40" MIN ABOVE THE BACKGROUND.

DOTS SHALL BE DOMED OR ROUNDED.

5. MOUNTING LOCATION AND HEIGHT:

INSTALL ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR.

WHERE NO WALL SPACE EXISTS ON THE LATCH SIDE OF THE DOOR (INCL.

DOUBLE LEAFS), PLACE SIGN ON THE NEAREST ADJACENT WALL,

PREFERABLY TO THE RIGHT SIDE.

HEIGHT: 60" ABOVE FINISH FLOOR TO THE CENTERLINE OF THE SIGN.

LOCATION: PLACE SO THE APPROACHING PERSON MAY APPROACH WITHIN

3" OF SIGNAGE WITHOUT WNCOUNTERING PROTRUDING OBJECTS OR

STANDING WITHIN THE SWINGING DOOR PATH.

DOORS

A. LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH-PULL OR PANIC TYPE

HARDWARE 30 INCHES TO 44 INCHES ABOVE FLOOR.

B. MAXIMUM FORCE TO OPERATE DOORS SHALL BE 5 LBS. PRESSURE. FIRE

DOORS SHALL BE 15 LBS. MAXIMUM.

C. FLOOR SHALL BE LEVEL AT ALL DOORS.

1. THRESHOLDS: THE FLOOR OR LANDING SHALL NOTE BE MORE THAN 1/2-INCH

LOWER THAN THE THRESHOLD OF THE DOOR WAY. CHANGE IN LEVEL

BETWEEN 1/4-INCH AND 1/2-INCH SHALL BE BEVELED WITH A SLOPE NO

GREATER THAN 1:2. (SEE BELOW).

2. LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL AND CLEAR AREA ON

EACH SIDE ON AN EXIT DOOR. THE LEVEL AREA SHALL BE AS ILLUSTRATED IN

FIGURE A. THE SPACE BETWEEN THE TWO CONSECUTIVE DOOR OPENING

(VESTIBULE) SHALL PROVIDE 48-INCHES OF CLEAR SPACE FROM ANY DOOR

OPENING INTO SUCH SPACE. (SEE BELOW)

D. DOOR WIDTH AND HEIGHT: 3-FEET WIDE AND 6-FEET-8-INCHES HIGH. CLEAR

WIDTH: 32-INCHES MINIMUM WITH DOOR OPEN 90-DEG. MEASURED FROM THE

FACE OF THE DRR TO THE OPPOSITE SIDE.

E. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING

SHALL HAVE A SMOOTH UNINTERUPTED SURFACE TO ALLOW THE DOOR TO BE

OPENED BY A WHEELCHAIR FOOT - REST WITHOUT CREATING A TRAP OR

HAZARDOUS CONDITION.

EACH GRADE LEVEL EXTERIOR DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH

THE WORDS 'EXIT'.

EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT MY

MEANS OF A STAIRWAY OR RAMP SHALL BE INDENTIFIED BY A TACTILE EXIT SIGN

WITH THE FOLLOWING WORDS AS APPROPRIATE:

1. 'EXIT STAIRS DOWN'

2. 'EXIT RAMP DOWN'

3. 'EXIT STAIR UP'

4. 'EXIT RAMP UP'

EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY

MEANS OF AN

EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL

BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS 'EXIT ROUTE'.

EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR

HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN SHALL BE INDENTIFIED BY

A TACTILE EXIT SIGN WITH THE

WORDS 'EXIT ROUTE'.

EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN

WITH THE WORDS

'TO EXIT'.

PROTRUDING OBJECTS

A. PROJECTIONS FROM WALLS WITH A LEADING EDGE BETWEEN 27 INCHES AND

80 INCHES ABOVE FLOOR MAY PROJECT 4 INCHES MAXIMUM. LEADING EDGE

AT OR BELOW 27 INCHES MAY PROJECT ANY AMOUNT. FREESTANDING

PROJECTIONS WITH LEADING EDGE BETWEEN 27 INCHES AND 80 INCHES

ABOVE FLOOR MAY PROJECT 12 INCHES MAX. PROJECTIONS MAY NOT

REDUCE MANEUVERING SPACE, OR CLEAR WIDTH OF AN ACCESSIBLE ROUTE.

B. PROVIDE MINIMUM OF 80 INCHES HEAD ROOM.

ELECTRICAL

A. ELECTRICAL RECEPTACLES (15, 20, AND 30 AMPS) SHALL BE AT LEAST 15

INCHES ABOVE THE FLOOR.

B. SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, COOLING, HEATING AND

VENTILATING EQUIPMENT SHALL BE NOT LESS THAN 36" AND NO MORE THAN

48" A.F.F.

C. FIRE ALARM INITIATING DEVISES SHALL BE 48" ABOVE THE FLOOR, GROUND OR

SIDEWALK.

SANITARY FACILITIES

A. GEOMETRIC SYMBOLS

1. SYMBOLS

A) MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL

TRIANGLE 1/4" THICK WITH SIDE 12" LONG AND VERTEX POINTING

UPWARD.

B) WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4"

THICK, 12" DIAMETER.

C) UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK,

12" DIAMETER, WITH A 1/4" THICK EQUILATERAL TRIANGLE

SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER.

2. GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BE

CENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR AND

CONTRAST SHALL BE DINSTINCTLY DIFFERENT FROM THE COLOR AND

CONTRAST OF THE DOOR.

3. RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPAINED BY

BRAILLE IN CONFORMANCE WITH SECTION 1117B.5.6. THEY SHALL BE

INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOE.

WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE

LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL,

PREFERABLY ON THE RIGHT. MOUNTNG HEIGHT SHALL BE 60 INCHES ABOVE

THE FINISH FLOOR TO THE CENTER OF THE SIGN. MOUNTING LOCATION SHALL

BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF

SIGNAGE WITHOUT ENCOUNTERING PROTUDING OBJECTS OR STANDING

WITHIN THE SWING OF THE DOOR.

SECTION 1117B.5.6

A) LETTER TYPE: LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32

INCH (0.794mm) MINIMUM AND SHALL BE SANS-SERIF UPPERCASE

CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.

B) SYMBOL SIZE: RAISED CHARACTERS OR SYMBOLS SHALL BE MINIMUM OF 5/8

INCH (15.9mm) HIGH.

C) PICTORAL SYMBOL SIGNS (PICTOGRAMS): PICTORAL SYMBOL SIGNS SHALL

BE ACCOMPANIED BY THE EQUIVELANT VERBAL DESCRIPTION PLACED

DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE

PICTOGRAM SHALL BE A MINIMUM OF 6 INCHES (152mm) IN HEIGHT.

B. ACCESSIBLE COMPARTMENT DOORS SHALL BE EQUIPPED WITH AN AUTOMATIC

CLOSING DEVICE. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR

SHALL BE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW

THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING OR OTHER

HARDWARE NOT REQUIREING THE USER TO GRASP OR TWIST.

C. WATER CLOSET: FLUSH CONTROLS ARE TO BE OPERABLE BY AN OSCILLATING

HANDLE WITH A MINIMUM OPERATING FORCE OF 3 LB./F OR BY A LOW

VOLTAGE BUTTON. THE HANDLE OR BUTTON IS TO BE LOCATED ON THE WIDE

SIDE SO AS TO BE OPERABLE WITHOUT REQUIREING EXCESSIVE BODY

MOVEMENT.

D. URINALS: PROVIDE ALL WALL HUNG URINALS WITH ELONGATED RIM. FLUSH

CONTROLS ARE TO BE HAND OPERATED AND ARE TO MEET THE SAME

REQUIREMENTS AS THE FLUSH CONTROLS FOR THE WATER CLOSET AND ARE

TO BE A MAXIMUM OF 44 INCHES ABOVE THE FLOOR. RIM ELEVATION TO BE 17

INCHES A.F.F.

E. LAVATORY: PROVIDE AT LEAST 29 INCHES FROM THE FLOOR TO THE BOTTOM

OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A

MINIMUM OF 30 INCHES WIDE. TO 8 INCHES MINIMUM DEPTH AT THE TOP.

PROVIDE FOR THE CLEARANCE AT LEAST 30 INCHES WIDE. TO 9 INCHES ABOVE

THE FLOOR AND 17 INCHES DEEP FROM THE FRONT OF THE LAVATORY.

PROVIDE A CLEAR FLOOR SPACE 30 INCHES x 48 INCHES IN FRON T OF THE

LAVAOTRY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE

UNDERNEATH THE LAVATORY. INSULATE HOT WATER AND DRAIN PIPES UNDER

LAVATORIES. NO SHARP OR ABRASIVE SURFACES ARE ALLOWED UNDER

LAVATORIES. FAUCET CONTROLS ARE REQUIRED TO BE OPEARABLE WITH

ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE

WRIST. THE FORCE NECESSARY TO OPERATE CONTROLS IS NOT TO EXCEED 5

LB./F.

F. ACCESSORIES: WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES

AND SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST

ONE OF EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING

COIN SLOTS, WITHIN 40 INCHES FROM THE FLOOR.

1. MOUNT MIRRORS WITH THE BOTTOM EDGE NO MORE THAN 40 INCHES A.F.F.

2. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12 INCHES OF THE

FRONT EDGE OF THE TOILET SEAT.

G. THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS AND MOUNTING

DEVICES SHALL MEET THE SPECIFICATIONS OF THE AMERICAN DISABILITES

ACT AND THE STATE OF CALIFORNIS TITLE 24.

H. SINGLE ACCOMODATION: A CLEAR FLOOR SPACE OF AT LEAST 60 INCHES IN

DIAMETER IS REQUIRED FOR SINGLE ACCOMODATION TOILET ROOMS.

DRINKING FOUNTAINS

CLEAR FLOOR SPACE.

A. A CLEAR FLOOR SPACE COMPLYING WITH SECTION 305, POSITIONED FOR A

FORWARD APPROACH TO THE DRINKING FOUNTAIN, SHALL BE PROVIDED. KNEE

AND TOE SPACE COMPLYING WITH SECTION 306 SHALL BE PROVIDED. THE

CLEAR FLOOR SPACE SHALL BE CENTERED ON THE DRINKING FOUNTAIN.

EXCEPTIONS:

A. DRINKING FOUNTAINS FOR STANDING PERSONS.

B. DRINKING FOUNTAINS PRIMARILY FOR CHILDREN'S USE SHALL BE PERMITTED

WHERE THE SPOUT IS 30 INCHES (760 MM) MAXIMUM ABOVE THE FLOOR, AND A

PARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THE

DRINKING FOUNTAIN, IS PROVIDED.

C. IN EXISTING BUILDINGS, EXISTING DRINKING FOUNTAINS PROVIDING A

PARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THE

DRINKING FOUNTAIN, SHALL BE PERMITTED.

D. WHERE SPECIFICALLY PERMITTED BY THE ADMINISTRATIVE AUTHORITY, A

PARALLEL APPROACH COMPLYING WITH SECTION 305, CENTERED ON THE

DRINKING FOUNTAIN, SHALL BE PERMITTED FOR DRINKING FOUNTAINS THAT

REPLACE EXISTING DRINKING FOUNTAINS WITH A PARALLEL APPROACH

OPERABLE PARTS

A. OPERABLE PARTS SHALL COMPLY WITH SECTION 309.

SPOUT OUTLET HEIGHT.

A. SPOUT OUTLETS OF WHEELCHAIR ACCESSIBLE DRINKING FOUNTAINS SHALL

BE 36 INCHES (915 MM) MAXIMUM ABOVE THE FLOOR. SPOUT OUTLETS OF

DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES (965 MM)

MINIMUM AND 43 INCHES (1090 MM) MAXIMUM ABOVE THE FLOOR.

SPOUT LOCATION

A. THE SPOUT SHALL BE LOCATED 15 INCHES (380 MM) MINIMUM FROM THE

VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM FROM THE FRONT EDGE

OF THE DRINKING FOUNTAIN, INCLUDING BUMPERS. WHERE ONLY A PARALLEL

APPROACH IS PROVIDED, THE SPOUT SHALL BE LOCATED 31/2 INCHES (89 MM)

MAXIMUM FROM THE FRONT EDGE OF THE DRINKING FOUNTAIN, INCLUDING

BUMPERS.

Fig. 404.2.4.1

Maneuvering Clearance at

Manual Swinging Doors

60

m

in

1525

18 min

445

(a) - front approach, pull side

12

20

48

m

in

12 min

305

(b) - front approach, push side, door

provided with both closer and latch

36 min

915

60

m

in

15

25

(c) - hinge approach, pull side

42 min

1065

54

m

in

13

70

(d) - hinge approach, pull side

42

m

in

**

10

65

560

22 min

(e) - hinge approach, push side

* If both closer and latch are provided

** 48" min. (1220) if both closer and

latch provided

305

12 min * 24 min

48

m

in

*

610

12

20

(f) - latch approach, pull side

* 54" min. (1370) if closer provided

24 min

42

m

in

*

10

65

610

(g) - latch approach, push side

* 48" min (1220) if closer provided

60 min

1525

60

m

in

15

25

(a)

60 min

1525

48

m

in

12

20

Do

or

wid

th

Do

or

wid

th

48

m

in

12

20

Do

or

wid

th

60 min

1525

(b)

(c)

Fig. 404.2.6

Two Doors in a Series

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_C

4.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

C4.0

GE

NE

RA

L IN

FO

RM

AT

IO

N

SBE SBE

AutoCAD SHX Text
4
Page 5: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_C

5.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

C5.0

CO

MC

HE

CK

GPD GPD

AutoCAD SHX Text
4
Page 6: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 011000 - SUMMARY

PART 1 GENERAL

1.01 PROJECT

A. PROJECT NAME: PET SUPPLIES PLUS - MARYVILLE, TN

B. THE PROJECT CONSISTS OF RENOVATIONS TO AN EXISTING VACANT

BUILDING AND SITE FOR A NEW PET SUPPLIES RETAIL STORE.

1.02 CONTRACT DESCRIPTION

A. CONTRACT TYPE: A SINGLE PRIME CONTRACT BASED ON A

STIPULATED PRICE AS DESCRIBED IN AIA OWNER - CONTRACTOR

AGREEMENT.

1.03 DESCRIPTION OF ALTERATIONS WORK

A. SCOPE OF DEMOLITION AND REMOVAL WORK IS SHOWN ON

DRAWINGS.

B. RENOVATE THE ENTIRE SPACE, COMPLETE AS INDICATED ON THE

DRAWINGS AND SPECIFIED HEREIN:

1.04 WORK BY OWNER

A. THE OWNER HAS AWARDED CONTRACTS FOR THE SUPPLY,

INSTALLATION OR THE SUPPLY AND INSTALLATION OF ITEMS

SCHEDULED ON THE DRAWINGS, WHICH WILL COMMENCE ON DATES

PRIOR TO TURNOVER FOR OWNER OCCUPANCY.

1.05 OWNER OCCUPANCY

A. THE OWNER INTENDS TO OCCUPY PORTIONS OF THE BUILDING PRIOR

TO THE COMPLETION DATE FOR INSTALLATION OF OWNER PROVIDED

MATERIALS.

B. SCHEDULE THE WORK TO ACCOMMODATE THE OWNER AND THE

OWNERS CONTRACTORS OCCUPANCY.

1.06 CONTRACTOR USE OF SITE

A. CONSTRUCTION OPERATIONS: LIMITED TO AREAS NOTED ON

DRAWINGS.

B. ARRANGE USE OF SITE TO ALLOW:

1. WORK BY OTHERS.

C. PROVIDE ACCESS TO AND FROM SITE AS REQUIRED BY LAW AND BY

THE OWNER:

1. EMERGENCY BUILDING EXITS DURING CONSTRUCTION: KEEP

ALL EXITS AT ADJACENT BUILDING OPERATING TENANTS AND

AS REQUIRED BY CODE OPEN DURING CONSTRUCTION PERIOD,

PROVIDE TEMPORARY EXIT SIGNS IF EXIT ROUTES ARE

TEMPORARILY ALTERED.

2. DO NOT OBSTRUCT ROADWAYS, SIDEWALKS, OR OTHER

PUBLIC WAYS WITHOUT PERMIT.

3. MAINTAIN ACCESS TO ADJACENT PROPERTY, COORDINATE

WITH CONSTRUCTION LIMITS ACCESS.

D. EXISTING BUILDING SPACES MAY NOT BE USED FOR STORAGE.

1.07 WORK SEQUENCE

A. COORDINATE CONSTRUCTION SCHEDULE AND OPERATIONS WITH THE

ARCHITECTS.

PART 2 PRODUCTS - NOT USED

PART 3 EXECUTION - NOT USED

END OF SECTION

SECTION 013000 - ADMINISTRATIVE REQUIREMENTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. PROGRESS REPORTING.

B. CONSTRUCTION PROGRESS SCHEDULE.

C. PROGRESS PHOTOGRAPHS.

D. COORDINATION DRAWINGS.

E. SUBMITTALS FOR REVIEW, INFORMATION, AND PROJECT CLOSEOUT.

F. SUBMITTAL PROCEDURES.

PART 2 PRODUCTS - NOT USED

PART 3 EXECUTION

3.01 PROGRESS REPORTING

A. SCHEDULE AND ADMINISTER REPORTING THROUGHOUT PROGRESS

OF THE WORK AT MAXIMUM WEEKLY INTERVALS OR AS REQUESTED

BY PET SUPPLIES PLUS REPRESENTATIVES.

B. REPORT ITEMS:

1. REVIEW OF WORK PROGRESS.

2. FIELD OBSERVATIONS, PROBLEMS, AND DECISIONS.

3. IDENTIFICATION OF PROBLEMS WHICH IMPEDE PLANNED

PROGRESS.

4. REVIEW OF SUBMITTALS SCHEDULE AND STATUS OF

SUBMITTALS.

5. REVIEW OF OFF-SITE FABRICATION, OWNER PROVIDED ITEMS

AND DELIVERY SCHEDULES.

6. MAINTENANCE OF PROGRESS SCHEDULE.

7. CORRECTIVE MEASURES TO REGAIN PROJECTED SCHEDULES.

8. PLANNED PROGRESS DURING SUCCEEDING WORK PERIOD.

9. MAINTENANCE OF QUALITY AND WORK STANDARDS.

10. EFFECT OF PROPOSED CHANGES ON PROGRESS SCHEDULE

AND COORDINATION.

11. PROGRESS PHOTOS, REFER TO REQUIREMENTS BELOW.

12. OTHER BUSINESS RELATING TO WORK.

C. PREPARE REPORT AND DISTRIBUTE VIA EMAIL ON THURSDAY

MORNING OF EACH WEEK. DISTRIBUTION TO INCLUDE OWNER,

ARCHITECT.

3.02 CONSTRUCTION PROGRESS SCHEDULE

A. CONSTRUCTION SCHEDULE SHALL BE ORGANIZED IN BAR CHART

FORMAT WITH SEPARATE BAR FOR EACH SUBSTRATE CATEGORY OF

WORK, ORGANIZE IN CHRONOLOGICAL ORDER ACCORDING TO THE

START DATE FOR EACH ACTIVITY OF WORK. IDENTIFY EACH ACTIVITY

BY APPLICABLE SPECIFICATION REFERENCE NUMBER.

B. WITHIN 3 DAYS AFTER DATE ESTABLISHED IN NOTICE TO PROCEED,

SUBMIT PRELIMINARY SCHEDULE FOR CONSTRUCTION OPERATIONS

FOR THE DURATION OF THE PROJECT. INCLUDE SCHEDULE FOR

ORDERING AND DELIVERY OF OWNER SUPPLIED ITEMS.

C. IF PRELIMINARY SCHEDULE REQUIRES REVISION AFTER REVIEW,

SUBMIT REVISED SCHEDULE WITHIN 2 DAYS.

D. WITHIN 10 DAYS AFTER JOINT REVIEW, SUBMIT COMPLETE SCHEDULE.

E. SUBMIT UPDATED SCHEDULE WITH EACH APPLICATION FOR PAYMENT.

3.03 PROGRESS PHOTOGRAPHS

A. PROVIDE PHOTOGRAPHS OF SITE AND CONSTRUCTION THROUGHOUT

PROGRESS OF WORK PRODUCED BY AN EXPERIENCED

PHOTOGRAPHER, ACCEPTABLE TO PET SUPPLIES PLUS AND

ARCHITECT.

B. PHOTOS SHALL BE DIGITAL .JPG IMAGES ASSEMBLED IN .ZIP FILE AND

EMAILED WITH WEEKLY PROGRESS REPORT.

C. TAKE PHOTOGRAPHS FOR SUBMITTAL WITH WEEKLY PROGRESS

REPORT OF MINIMUM ITEMS AS FOLLOWS AND APPLICABLE TO

WORKSCOPE OF PROJECT:

1. DEMOLITION

2. EXCAVATION AND UNDERGROUND PLUMBING

3. ROUGH FRAMING INCLUDING ALL CONCEALED BLOCKING

4. PLUMBING WALL ROUGH IN

5. ELECTRICAL WALL ROUGH IN

6. HVAC ROUGH IN

7. ELECTRICAL OVERHEAD

8. WALLS PRIOR TO GYPSUM BOARD

9. WALLS AFTER GYPSUM BOARD

10. CEILING GRID INSTALLATION

11. FLOOR TILE

12. OWNER SUPPLIED CABINETRY AND KITCHEN EQUIPMENT AT

DELIVERY

13. OWNER SUPPED CABINETRY AND KITCHEN EQUIPMENT AT

INSTALLATION

14. PAINTING

15. INTERIOR FINISHES AND DECOR

16. EXTERIOR DRIVE THRU RELATED WORK

17. EXTERIOR LIFT, LOADING AREA AND RELATED WORK

18. ADDITIONAL ITEMS AS REQUESTED BY OWNER, ARCHITECT

AND PET SUPPLIES PLUS

3.04 COORDINATION DRAWINGS AND FIELD DIMENSIONS

A. PROVIDE INFORMATION REQUIRED BY OWNER, ARCHITECT OR PET

SUPPLIES PLUS VENDOR FOR PREPARATION OF COORDINATION

DRAWINGS.

3.05 SUBMITTALS FOR REVIEW

A. WHEN THE FOLLOWING ARE SPECIFIED IN INDIVIDUAL SECTIONS,

SUBMIT THEM FOR REVIEW:

1. PRODUCT DATA.

2. SHOP DRAWINGS.

3. SAMPLES FOR SELECTION.

4. SAMPLES FOR VERIFICATION.

B. SUBMIT TO ARCHITECT FOR REVIEW FOR THE LIMITED PURPOSE OF

CHECKING FOR CONFORMANCE WITH INFORMATION GIVEN AND THE

DESIGN CONCEPT EXPRESSED IN THE CONTRACT DOCUMENTS.

C. SAMPLES WILL BE REVIEWED ONLY FOR AESTHETIC, COLOR, OR

FINISH SELECTION.

D. AFTER REVIEW, PROVIDE COPIES AND DISTRIBUTE IN ACCORDANCE

WITH SUBMITTAL PROCEDURES ARTICLE BELOW AND FOR RECORD

DOCUMENTS PURPOSES DESCRIBED IN SECTION 017700 - CLOSEOUT

SUBMITTALS.

3.06 SUBMITTALS FOR INFORMATION

A. WHEN THE FOLLOWING ARE SPECIFIED IN INDIVIDUAL SECTIONS,

SUBMIT THEM FOR INFORMATION:

1. DESIGN DATA.

2. CERTIFICATES.

3. TEST REPORTS.

4. INSPECTION REPORTS.

5. MANUFACTURER'S INSTRUCTIONS.

6. MANUFACTURER'S FIELD REPORTS.

7. OTHER TYPES INDICATED.

B. SUBMIT FOR ARCHITECT'S KNOWLEDGE AS CONTRACT

ADMINISTRATOR OR FOR OWNER. NO ACTION WILL BE TAKEN.

3.07 SUBMITTALS FOR PROJECT CLOSEOUT

A. WHEN THE FOLLOWING ARE SPECIFIED IN INDIVIDUAL SECTIONS,

SUBMIT THEM AT PROJECT CLOSEOUT:

1. PROJECT RECORD DOCUMENTS.

2. OPERATION AND MAINTENANCE DATA.

3. WARRANTIES.

4. OTHER TYPES AS INDICATED.

B. SUBMIT FOR OWNER'S BENEFIT DURING AND AFTER PROJECT

COMPLETION.

END OF SECTION

SECTION 014000 - QUALITY REQUIREMENTS

PART 1 GENERAL.

1.01 REFERENCES AND STANDARDS

A. FOR PRODUCTS AND WORKMANSHIP SPECIFIED BY REFERENCE TO A

DOCUMENT OR DOCUMENTS NOT INCLUDED IN THE PROJECT MANUAL,

ALSO REFERRED TO AS REFERENCE STANDARDS, COMPLY WITH

REQUIREMENTS OF THE STANDARD, EXCEPT WHEN MORE RIGID

REQUIREMENTS ARE SPECIFIED OR ARE REQUIRED BY APPLICABLE

CODES.

B. CONFORM TO REFERENCE STANDARD OF DATE OF ISSUE CURRENT

ON DATE OF CONTRACT DOCUMENTS, EXCEPT WHERE A SPECIFIC

DATE IS ESTABLISHED BY APPLICABLE CODE.

C. OBTAIN COPIES OF STANDARDS WHERE REQUIRED BY PRODUCT

SPECIFICATION SECTIONS.

D. MAINTAIN COPY AT PROJECT SITE DURING SUBMITTALS, PLANNING,

AND PROGRESS OF THE SPECIFIC WORK, UNTIL SUBSTANTIAL

COMPLETION.

E. SHOULD SPECIFIED REFERENCE STANDARDS CONFLICT WITH

CONTRACT DOCUMENTS, REQUEST CLARIFICATION FROM THE

ARCHITECTS BEFORE PROCEEDING.

F. NEITHER THE CONTRACTUAL RELATIONSHIPS, DUTIES, OR

RESPONSIBILITIES OF THE PARTIES IN CONTRACT NOR THOSE OF THE

ARCHITECTS SHALL BE ALTERED FROM THE CONTRACT DOCUMENTS

BY MENTION OR INFERENCE OTHERWISE IN ANY REFERENCE

DOCUMENT.

PART 2 PRODUCTS - NOT USED

PART 3 EXECUTION

3.01 CONTROL OF INSTALLATION

A. MONITOR QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS,

PRODUCTS, SERVICES, SITE CONDITIONS, AND WORKMANSHIP, TO

PRODUCE WORK OF SPECIFIED QUALITY.

B. COMPLY WITH MANUFACTURERS' INSTRUCTIONS, INCLUDING EACH

STEP IN SEQUENCE.

C. SHOULD MANUFACTURERS' INSTRUCTIONS CONFLICT WITH

CONTRACT DOCUMENTS, REQUEST CLARIFICATION FROM THE

ARCHITECTS BEFORE PROCEEDING.

D. COMPLY WITH SPECIFIED STANDARDS AS MINIMUM QUALITY FOR THE

WORK EXCEPT WHERE MORE STRINGENT TOLERANCES, CODES, OR

SPECIFIED REQUIREMENTS INDICATE HIGHER STANDARDS OR MORE

PRECISE WORKMANSHIP.

E. HAVE WORK PERFORMED BY PERSONS QUALIFIED TO PRODUCE

REQUIRED AND SPECIFIED QUALITY.

F. VERIFY THAT FIELD MEASUREMENTS ARE AS INDICATED ON SHOP

DRAWINGS OR AS INSTRUCTED BY THE MANUFACTURER.

G. SECURE PRODUCTS IN PLACE WITH POSITIVE ANCHORAGE DEVICES

DESIGNED AND SIZED TO WITHSTAND STRESSES, VIBRATION,

PHYSICAL DISTORTION, AND DISFIGUREMENT.

3.02 TOLERANCES

A. MONITOR FABRICATION AND INSTALLATION TOLERANCE CONTROL OF

PRODUCTS TO PRODUCE ACCEPTABLE WORK. DO NOT PERMIT

TOLERANCES TO ACCUMULATE.

B. COMPLY WITH MANUFACTURERS' TOLERANCES. SHOULD

MANUFACTURERS' TOLERANCES CONFLICT WITH CONTRACT

DOCUMENTS, REQUEST CLARIFICATION FROM THE ARCHITECTS

BEFORE PROCEEDING.

C. ADJUST PRODUCTS TO APPROPRIATE DIMENSIONS, POSITION BEFORE

SECURING PRODUCTS IN PLACE.

3.03 DEFECT ASSESSMENT

A. REPLACE WORK OR PORTIONS OF THE WORK NOT CONFORMING TO

SPECIFIED REQUIREMENTS.

B. IF, IN THE OPINION OF THE ARCHITECTS, IT IS NOT PRACTICAL TO

REMOVE AND REPLACE THE WORK, THE ARCHITECTS WILL DIRECT AN

APPROPRIATE REMEDY OR ADJUST PAYMENT.

END OF SECTION

SECTION 015000 - TEMPORARY FACILITIES AND CONTROLS

PART 1 GENERAL

1.01 TEMPORARY UTILITIES

A. USE TRIGGER-OPERATED NOZZLES FOR WATER HOSES, TO AVOID

WASTE OF WATER.

1.02 TEMPORARY SANITARY FACILITIES

A. PROVIDE AND MAINTAIN REQUIRED FACILITIES AND ENCLOSURES.

PROVIDE AT TIME OF PROJECT MOBILIZATION.

B. USE OF EXISTING FACILITIES IS PERMITTED.

C. MAINTAIN DAILY IN CLEAN AND SANITARY CONDITION.

1.03 BARRIERS

A. PROVIDE BARRIERS TO PREVENT UNAUTHORIZED ENTRY TO

CONSTRUCTION AREAS, TO ALLOW FOR OWNER'S USE OF SITE AND

TO PROTECT EXISTING FACILITIES AND ADJACENT PROPERTIES FROM

DAMAGE FROM CONSTRUCTION OPERATIONS AND DEMOLITION.

B. PROVIDE BARRICADES AND COVERED WALKWAYS REQUIRED BY

GOVERNING AUTHORITIES FOR PUBLIC RIGHTS-OF-WAY AND FOR

PUBLIC ACCESS TO EXISTING BUILDING.

C. PROTECT NON-OWNED VEHICULAR TRAFFIC, STORED MATERIALS,

SITE, AND STRUCTURES FROM DAMAGE.

1.04 EXTERIOR ENCLOSURES

A. PROVIDE TEMPORARY INSULATED WEATHER TIGHT CLOSURE OF

EXTERIOR OPENINGS TO ACCOMMODATE ACCEPTABLE WORKING

CONDITIONS AND PROTECTION FOR PRODUCTS, TO ALLOW FOR

TEMPORARY HEATING AND MAINTENANCE OF REQUIRED AMBIENT

TEMPERATURES IDENTIFIED IN INDIVIDUAL SPECIFICATION SECTIONS,

AND TO PREVENT ENTRY OF UNAUTHORIZED PERSONS. PROVIDE

ACCESS DOORS WITH SELF-CLOSING HARDWARE AND LOCKS.

1.05 SECURITY

A. PROVIDE SECURITY AND FACILITIES TO PROTECT WORK, EXISTING

FACILITIES, AND THE OWNER'S OPERATIONS FROM UNAUTHORIZED

ENTRY, VANDALISM, OR THEFT.

1.06 VEHICULAR ACCESS AND PARKING

A. COORDINATE ACCESS AND HAUL ROUTES WITH GOVERNING

AUTHORITIES AND THE OWNER.

B. PROVIDE AND MAINTAIN ACCESS TO FIRE HYDRANTS, FREE OF

OBSTRUCTIONS.

C. PROVIDE MEANS OF REMOVING MUD FROM VEHICLE WHEELS BEFORE

ENTERING STREETS.

D. PROVIDE TEMPORARY PARKING AREAS TO ACCOMMODATE

CONSTRUCTION PERSONNEL. WHEN SITE SPACE IS NOT ADEQUATE,

PROVIDE ADDITIONAL OFF-SITE PARKING.

1.07 WASTE REMOVAL

A. PROVIDE WASTE REMOVAL FACILITIES AND SERVICES AS REQUIRED

TO MAINTAIN THE SITE IN CLEAN AND ORDERLY CONDITION.

B. PROVIDE CONTAINERS WITH LIDS. REMOVE TRASH FROM SITE

PERIODICALLY.

C. IF MATERIALS TO BE RECYCLED OR RE-USED ON THE PROJECT MUST

BE STORED ON-SITE, PROVIDE SUITABLE NON-COMBUSTIBLE

CONTAINERS, LOCATE CONTAINERS HOLDING FLAMMABLE MATERIAL

OUTSIDE THE STRUCTURE UNLESS OTHERWISE APPROVED BY THE

AUTHORITIES HAVING JURISDICTION.

D. OPEN FREE-FALL CHUTES ARE NOT PERMITTED. TERMINATE CLOSED

CHUTES INTO APPROPRIATE CONTAINERS WITH LIDS.

1.08 REMOVAL OF UTILITIES, FACILITIES, AND CONTROLS

A. REMOVE TEMPORARY UTILITIES, EQUIPMENT, FACILITIES, MATERIALS,

PRIOR TO SUBSTANTIAL COMPLETION INSPECTION.

B. REMOVE UNDERGROUND INSTALLATIONS TO A MINIMUM DEPTH OF 2

FEET (600 MM) OR AS INDICATED ON DRAWINGS. GRADE SITE AS

INDICATED.

C. CLEAN AND REPAIR DAMAGE CAUSED BY INSTALLATION OR USE OF

TEMPORARY WORK.

D. RESTORE EXISTING FACILITIES USED DURING CONSTRUCTION TO

ORIGINAL CONDITION.

PART 2 PRODUCTS - NOT USED

PART 3 EXECUTION - NOT USED

END OF SECTION

SECTION 016000 - PRODUCT REQUIREMENTS

PART 1 GENERAL

1.01 REFERENCES

A. NFPA 70 - NATIONAL ELECTRICAL CODE, NATIONAL FIRE PROTECTION

ASSOCIATION, 2002.

1.02 SUBMITTALS

A. PROPOSED PRODUCTS LIST: SUBMIT LIST OF MAJOR PRODUCTS

PROPOSED FOR USE, WITH NAME OF MANUFACTURER, TRADE NAME,

AND MODEL NUMBER OF EACH PRODUCT.

1. SUBMIT WITHIN 15 DAYS AFTER DATE OF AGREEMENT.

B. PRODUCT DATA SUBMITTALS: SUBMIT MANUFACTURER'S STANDARD

PUBLISHED DATA. MARK EACH COPY TO IDENTIFY APPLICABLE

PRODUCTS, MODELS, OPTIONS, AND OTHER DATA. SUPPLEMENT

MANUFACTURERS' STANDARD DATA TO PROVIDE INFORMATION

SPECIFIC TO THIS PROJECT.

C. SHOP DRAWING SUBMITTALS: PREPARED SPECIFICALLY FOR THIS

PROJECT.

D. SAMPLE SUBMITTALS: ILLUSTRATE FUNCTIONAL AND AESTHETIC

CHARACTERISTICS OF THE PRODUCT, WITH INTEGRAL PARTS AND

ATTACHMENT DEVICES. COORDINATE SAMPLE SUBMITTALS FOR

INTERFACING WORK.

1. FOR SELECTION FROM STANDARD FINISHES, SUBMIT SAMPLES

OF THE FULL RANGE OF THE MANUFACTURER'S STANDARD

COLORS, TEXTURES, AND PATTERNS.

E. INDICATE UTILITY AND ELECTRICAL CHARACTERISTICS, UTILITY

CONNECTION REQUIREMENTS, AND LOCATION OF UTILITY OUTLETS

FOR SERVICE FOR FUNCTIONAL EQUIPMENT AND APPLIANCES.

PART 2 PRODUCTS

2.01 EXISTING PRODUCTS

A. EXISTING MATERIALS AND EQUIPMENT INDICATED TO BE REMOVED,

BUT NOT TO BE RE-USED, RELOCATED, REINSTALLED, DELIVERED TO

THE THE OWNER, OR OTHERWISE INDICATED AS TO REMAIN THE

PROPERTY OF THE THE OWNER, BECOME THE PROPERTY OF THE,

REMOVE FROM SITE.

2.02 NEW PRODUCTS

A. PROVIDE NEW PRODUCTS UNLESS SPECIFICALLY REQUIRED OR

PERMITTED BY THE CONTRACT DOCUMENTS.

B. DO NOT USE PRODUCTS HAVING ANY OF THE FOLLOWING

CHARACTERISTICS:

1. MADE USING OR CONTAINING CFC'S OR HCFC'S.

2.03 PRODUCT OPTIONS

A. PRODUCTS SPECIFIED BY REFERENCE STANDARDS OR BY

DESCRIPTION ONLY: USE ANY PRODUCT MEETING THOSE

STANDARDS OR DESCRIPTION.

B. PRODUCTS SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS:

USE A PRODUCT OF ONE OF THE MANUFACTURERS NAMED AND

MEETING SPECIFICATIONS, NO OPTIONS OR SUBSTITUTIONS

ALLOWED.

C. PRODUCTS SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS

WITH A PROVISION FOR SUBSTITUTIONS: SUBMIT A REQUEST FOR

SUBSTITUTION FOR ANY MANUFACTURER NOT NAMED.

2.04 SPARE PARTS AND MAINTENANCE PRODUCTS

A. PROVIDE SPARE PARTS, MAINTENANCE, AND EXTRA PRODUCTS OF

TYPES AND IN QUANTITIES SPECIFIED IN INDIVIDUAL SPECIFICATION

SECTIONS.

B. DELIVER TO PROJECT SITE, OBTAIN RECEIPT PRIOR TO FINAL

PAYMENT.

PART 3 EXECUTION

3.01 SUBSTITUTION PROCEDURES

A. INSTRUCTIONS TO BIDDERS SPECIFY TIME RESTRICTIONS FOR

SUBMITTING REQUESTS FOR SUBSTITUTIONS DURING THE BIDDING

PERIOD. COMPLY WITH REQUIREMENTS SPECIFIED IN THIS SECTION.

B. THE ARCHITECTS AND THE OWNER WILL CONSIDER REQUESTS FOR

SUBSTITUTIONS ONLY WITHIN 15 DAYS AFTER DATE OF AGREEMENT.

C. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN A PRODUCT

BECOMES UNAVAILABLE THROUGH NO FAULT OF THE OWNER.

D. DOCUMENT EACH REQUEST WITH COMPLETE DATA SUBSTANTIATING

COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT

DOCUMENTS.

E. A REQUEST FOR SUBSTITUTION CONSTITUTES A REPRESENTATION

THAT THE SUBMITTER:

1. HAS INVESTIGATED PROPOSED PRODUCT AND DETERMINED

THAT IT MEETS OR EXCEEDS THE QUALITY LEVEL OF THE

SPECIFIED PRODUCT.

2. WILL PROVIDE THE SAME WARRANTY FOR THE SUBSTITUTION

AS FOR THE SPECIFIED PRODUCT.

3. WILL COORDINATE INSTALLATION AND MAKE CHANGES TO

OTHER WORK, WHICH MAY BE REQUIRED FOR THE WORK TO

BE COMPLETE WITH NO ADDITIONAL COST TO THE OWNER.

4. WAIVES CLAIMS FOR ADDITIONAL COSTS OR TIME EXTENSION,

WHICH MAY SUBSEQUENTLY BECOME APPARENT.

5. WILL REIMBURSE THE OWNER AND THE ARCHITECTS FOR

REVIEW OR REDESIGN SERVICES ASSOCIATED WITH

RE-APPROVAL BY AUTHORITIES.

F. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE

INDICATED OR IMPLIED ON SHOP DRAWING OR PRODUCT DATA

SUBMITTALS, WITHOUT SEPARATE WRITTEN REQUEST, OR WHEN

ACCEPTANCE WILL REQUIRE REVISION TO THE CONTRACT

DOCUMENTS.

G. SUBSTITUTION SUBMITTAL PROCEDURE:

1. SUBMIT THREE COPIES OF REQUEST FOR SUBSTITUTION FOR

CONSIDERATION. LIMIT EACH REQUEST TO ONE PROPOSED

SUBSTITUTION.

2. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND CERTIFIED

TEST RESULTS ATTESTING TO THE PROPOSED PRODUCT

EQUIVALENCE. BURDEN OF PROOF IS ON PROPOSER.

3. THE ARCHITECTS WILL NOTIFY IN WRITING OF DECISION TO

ACCEPT OR REJECT REQUEST.

3.02 OWNER-SUPPLIED PRODUCTS

A. REFER TO DRAWINGS FOR IDENTIFICATION OF OWNER-SUPPLIED

PRODUCTS.

B. OWNER'S RESPONSIBILITIES:

1. ARRANGE FOR AND DELIVER APPLICABLE OWNER REVIEWED

SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES, TO

CONTRACTOR .

2. ARRANGE AND PAY FOR PRODUCT DELIVERY TO SITE.

3. ARRANGE FOR MANUFACTURERS' WARRANTIES, INSPECTIONS,

AND SERVICE.

C. CONTRACTOR'S RESPONSIBILITIES:

1. REVIEW OWNER REVIEWED SHOP DRAWINGS, PRODUCT DATA,

AND SAMPLES.

2. RECEIVE AND UNLOAD PRODUCTS AT SITE, INSPECT FOR

COMPLETENESS OR DAMAGE. ALL DAMAGED OR MISSING

MATERIALS SHALL BE DOCUMENTED TO OWNER & SUPPLIER

WITHIN THREE DAYS OF RECEIVING DELIVERY OF MATERIALS.

DAMAGED OR MISSING MATERIALS IDENTIFIED AFTER THREE

DAYS FROM DELIVERY ARE THE CONTRACTORS

RESPONSIBILITY TO REPLACE AT CONTRACTORS COST FOR

MATERIAL AND SHIPPING. COORDINATE REPLACEMENT WITH

OWNER AND SUPPLIER.

3. ALL MATERIALS SHALL BE STORED IN A SECURE LOCATION,

PROTECT FROM DAMAGE & THEFT.

4. HANDLE, STORE, INSTALL AND FINISH PRODUCTS.

3.03 TRANSPORTATION AND HANDLING

A. COORDINATE SCHEDULE OF PRODUCT DELIVERY TO DESIGNATED

PREPARED AREAS IN ORDER TO MINIMIZE SITE STORAGE TIME AND

POTENTIAL DAMAGE TO STORED MATERIALS.

B. TRANSPORT AND HANDLE PRODUCTS IN ACCORDANCE WITH

MANUFACTURER'S INSTRUCTIONS.

C. TRANSPORT MATERIALS IN COVERED TRUCKS TO PREVENT

CONTAMINATION OF PRODUCT AND LITTERING OF SURROUNDING

AREAS.

D. PROMPTLY INSPECT SHIPMENTS TO ENSURE THAT PRODUCTS

COMPLY WITH REQUIREMENTS, QUANTITIES ARE CORRECT, AND

PRODUCTS ARE UNDAMAGED.

E. PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY

METHODS TO PREVENT SOILING, DISFIGUREMENT, OR DAMAGE.

F. ARRANGE FOR THE RETURN OF PACKING MATERIALS, SUCH AS WOOD

PALLETS, WHERE ECONOMICALLY FEASIBLE.

3.04 STORAGE AND PROTECTION

A. DESIGNATE RECEIVING/STORAGE AREAS FOR INCOMING PRODUCTS

SO THAT THEY ARE DELIVERED ACCORDING TO INSTALLATION

SCHEDULE AND PLACED CONVENIENT TO WORK AREA IN ORDER TO

MINIMIZE WASTE DUE TO EXCESSIVE MATERIALS HANDLING AND

MISAPPLICATION.

B. STORE AND PROTECT PRODUCTS IN ACCORDANCE WITH

MANUFACTURERS' INSTRUCTIONS.

C. STORE WITH SEALS AND LABELS INTACT AND LEGIBLE.

D. STORE SENSITIVE PRODUCTS IN WEATHER TIGHT, CLIMATE

CONTROLLED, ENCLOSURES IN AN ENVIRONMENT FAVORABLE TO

PRODUCT.

E. FOR EXTERIOR STORAGE OF FABRICATED PRODUCTS, PLACE ON

SLOPED SUPPORTS ABOVE GROUND.

F. COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS

SHEET COVERING. PROVIDE VENTILATION TO PREVENT

CONDENSATION AND DEGRADATION OF PRODUCTS.

G. PREVENT CONTACT WITH MATERIAL THAT MAY CAUSE CORROSION,

DISCOLORATION, OR STAINING.

H. PROVIDE EQUIPMENT AND PERSONNEL TO STORE PRODUCTS BY

METHODS TO PREVENT SOILING, DISFIGUREMENT, OR DAMAGE.

I. ARRANGE STORAGE OF PRODUCTS TO PERMIT ACCESS FOR

INSPECTION. PERIODICALLY INSPECT TO VERIFY PRODUCTS ARE

UNDAMAGED AND ARE MAINTAINED IN ACCEPTABLE CONDITION.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.0

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.0

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 7: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 017300 - EXECUTION

PART 1 GENERAL

1.01 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. SURVEY WORK: SUBMIT NAME, ADDRESS, AND TELEPHONE NUMBER

OF SURVEYOR BEFORE STARTING SURVEY WORK.

1. ON REQUEST, SUBMIT DOCUMENTATION VERIFYING

ACCURACY OF SURVEY WORK.

2. SUBMIT A COPY OF SITE DRAWING SIGNED BY THE LAND

SURVEYOR THAT THE ELEVATIONS AND LOCATIONS OF THE

WORK ARE IN CONFORMANCE WITH CONTRACT DOCUMENTS.

3. SUBMIT SURVEYS AND SURVEY LOGS FOR THE PROJECT

RECORD.

C. DEMOLITION PLAN: SUBMIT DEMOLITION PLAN AS SPECIFIED BY EPA,

OSHA AND GOVERNING AUTHORITIES.

1. INDICATE EXTENT OF DEMOLITION, REMOVAL SEQUENCE,

BRACING AND SHORING, AND LOCATION AND CONSTRUCTION

OF BARRICADES AND FENCES.

2. IDENTIFY DEMOLITION FIRM AND SUBMIT QUALIFICATIONS.

3. INCLUDE A SUMMARY OF SAFETY PROCEDURES.

4. INCLUDE SUMMARY OF DEMOLITION AND REMOVAL OF

ASBESTOS MATERIALS.

D. CUTTING AND PATCHING: SUBMIT WRITTEN REQUEST IN ADVANCE OF

CUTTING OR ALTERATION, WHICH AFFECTS:

1. STRUCTURAL INTEGRITY OF ANY ELEMENT OF PROJECT.

2. INTEGRITY OF WEATHER EXPOSED OR MOISTURE RESISTANT

ELEMENT.

3. EFFICIENCY, MAINTENANCE, OR SAFETY OF ANY OPERATIONAL

ELEMENT.

4. VISUAL QUALITIES OF SIGHT EXPOSED ELEMENTS.

5. WORK OF THE OWNER OR SEPARATE CONTRACTOR.

E. PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL

LOCATIONS OF CAPPED AND ACTIVE UTILITIES.

1.02 QUALIFICATIONS

A. FOR SURVEY WORK, EMPLOY A LAND SURVEYOR REGISTERED IN AND

ACCEPTABLE TO THE OWNER. SUBMIT EVIDENCE OF SURVEYOR'S

ERRORS AND OMISSIONS INSURANCE COVERAGE IN THE FORM OF AN

INSURANCE CERTIFICATE.

1.03 PROJECT CONDITIONS

A. PROTECT SITE FROM PUDDLING OR RUNNING WATER. PROVIDE

WATER BARRIERS AS REQUIRED TO PROTECT SITE FROM SOIL

EROSION.

B. VENTILATE ENCLOSED AREAS TO ASSIST CURE OF MATERIALS, TO

DISSIPATE HUMIDITY, AND TO PREVENT ACCUMULATION OF DUST,

FUMES, VAPORS, OR GASES.

C. DUST CONTROL: EXECUTE WORK BY METHODS TO MINIMIZE RAISING

DUST FROM CONSTRUCTION OPERATIONS. PROVIDE POSITIVE MEANS

TO PREVENT AIR-BORNE DUST FROM DISPERSING INTO ATMOSPHERE.

D. EROSION AND SEDIMENT CONTROL: PLAN AND EXECUTE WORK BY

METHODS TO CONTROL SURFACE DRAINAGE FROM CUTS AND FILLS,

FROM BORROW AND WASTE DISPOSAL AREAS. PREVENT EROSION

AND SEDIMENTATION.

E. PEST CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES TO

PREVENT PESTS AND INSECTS FROM DAMAGING THE WORK.

F. RODENT CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES TO

PREVENT RODENTS FROM ACCESSING OR INVADING PREMISES.

G. POLLUTION CONTROL: PROVIDE METHODS, MEANS, AND FACILITIES

TO PREVENT CONTAMINATION OF SOIL, WATER, AND ATMOSPHERE

FROM DISCHARGE OF NOXIOUS, TOXIC SUBSTANCES, AND

POLLUTANTS PRODUCED BY CONSTRUCTION OPERATIONS.

1.04 COORDINATION

A. COORDINATE SCHEDULING, SUBMITTALS, AND WORK OF THE VARIOUS

SECTIONS OF THE PROJECT MANUAL TO ENSURE EFFICIENT AND

ORDERLY SEQUENCE OF INSTALLATION OF INTERDEPENDENT

CONSTRUCTION ELEMENTS, WITH PROVISIONS FOR ACCOMMODATING

ITEMS INSTALLED LATER.

B. NOTIFY AFFECTED UTILITY COMPANIES AND COMPLY WITH THEIR

REQUIREMENTS.

C. VERIFY THAT UTILITY REQUIREMENTS AND CHARACTERISTICS OF NEW

OPERATING EQUIPMENT ARE COMPATIBLE WITH BUILDING UTILITIES.

COORDINATE WORK OF VARIOUS SECTIONS HAVING

INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTING

TO, AND PLACING IN SERVICE, SUCH EQUIPMENT.

D. COORDINATE SPACE REQUIREMENTS, SUPPORTS, AND INSTALLATION

OF MECHANICAL AND ELECTRICAL WORK WHICH ARE INDICATED

DIAGRAMMATICALLY ON DRAWINGS. FOLLOW ROUTING SHOWN FOR

PIPES, DUCTS, AND CONDUIT, AS CLOSELY AS PRACTICABLE, PLACE

RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES

EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER

INSTALLATIONS, FOR MAINTENANCE, AND FOR REPAIRS.

E. IN FINISHED AREAS EXCEPT AS OTHERWISE INDICATED, CONCEAL

PIPES, DUCTS, AND WIRING WITHIN THE CONSTRUCTION.

COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISH

ELEMENTS.

F. COORDINATE COMPLETION AND CLEAN UP OF WORK OF SEPARATE

SECTIONS.

G. AFTER THE OWNER OCCUPANCY OF PREMISES, COORDINATE ACCESS

TO SITE FOR CORRECTION OF DEFECTIVE WORK AND WORK NOT IN

ACCORDANCE WITH CONTRACT DOCUMENTS, TO MINIMIZE

DISRUPTION OF THE OWNER'S ACTIVITIES.

PART 2 PRODUCTS

2.01 PATCHING MATERIALS

A. NEW MATERIALS: AS SPECIFIED IN PRODUCT SECTIONS, MATCH

EXISTING PRODUCTS AND WORK FOR PATCHING AND EXTENDING

WORK.

B. TYPE AND QUALITY OF EXISTING PRODUCTS: DETERMINE BY

INSPECTING AND TESTING PRODUCTS WHERE NECESSARY,

REFERRING TO EXISTING WORK AS A STANDARD.

C. PRODUCT SUBSTITUTION: FOR ANY PROPOSED CHANGE IN

MATERIALS, SUBMIT REQUEST FOR SUBSTITUTION DESCRIBED IN

SECTION 016000.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT EXISTING SITE CONDITIONS AND SUBSTRATE SURFACES

ARE ACCEPTABLE FOR SUBSEQUENT WORK. START OF WORK MEANS

ACCEPTANCE OF EXISTING CONDITIONS.

B. VERIFY THAT EXISTING SUBSTRATE IS CAPABLE OF STRUCTURAL

SUPPORT OR ATTACHMENT OF NEW WORK BEING APPLIED OR

ATTACHED.

C. EXAMINE AND VERIFY SPECIFIC CONDITIONS DESCRIBED IN

INDIVIDUAL SPECIFICATION SECTIONS.

D. TAKE FIELD MEASUREMENTS BEFORE CONFIRMING PRODUCT

ORDERS OR BEGINNING FABRICATION, TO MINIMIZE WASTE DUE TO

OVER-ORDERING OR MIS-FABRICATION.

E. VERIFY THAT UTILITY SERVICES ARE AVAILABLE, OF THE CORRECT

CHARACTERISTICS, AND IN THE CORRECT LOCATIONS.

F. PRIOR TO CUTTING: EXAMINE EXISTING CONDITIONS PRIOR TO

COMMENCING WORK, INCLUDING ELEMENTS SUBJECT TO DAMAGE OR

MOVEMENT DURING CUTTING AND PATCHING. AFTER UNCOVERING

EXISTING WORK, ASSESS CONDITIONS AFFECTING PERFORMANCE OF

WORK. BEGINNING OF CUTTING OR PATCHING MEANS ACCEPTANCE

OF EXISTING CONDITIONS.

3.02 PREPARATION

A. CLEAN SUBSTRATE SURFACES PRIOR TO APPLYING NEXT MATERIAL

OR SUBSTANCE.

B. SEAL CRACKS OR OPENINGS OF SUBSTRATE PRIOR TO APPLYING

NEXT MATERIAL OR SUBSTANCE.

C. APPLY MANUFACTURER REQUIRED OR RECOMMENDED SUBSTRATE

PRIMER, SEALER, OR CONDITIONER PRIOR TO APPLYING ANY NEW

MATERIAL OR SUBSTANCE IN CONTACT OR BOND.

3.03 GENERAL INSTALLATION REQUIREMENTS

A. INSTALL PRODUCTS AS SPECIFIED IN INDIVIDUAL SECTIONS, IN

ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND

RECOMMENDATIONS, AND SO AS TO AVOID WASTE DUE TO

NECESSITY FOR REPLACEMENT.

B. MAKE VERTICAL ELEMENTS PLUMB AND HORIZONTAL ELEMENTS

LEVEL, UNLESS OTHERWISE INDICATED.

C. INSTALL EQUIPMENT AND FITTINGS PLUMB AND LEVEL, NEATLY

ALIGNED WITH ADJACENT VERTICAL AND HORIZONTAL LINES, UNLESS

OTHERWISE INDICATED.

D. MAKE CONSISTENT TEXTURE ON SURFACES, WITH SEAMLESS

TRANSITIONS, UNLESS OTHERWISE INDICATED.

E. MAKE NEAT TRANSITIONS BETWEEN DIFFERENT SURFACES,

MAINTAINING TEXTURE AND APPEARANCE.

3.04 ALTERATIONS

A. DRAWINGS SHOWING EXISTING CONSTRUCTION AND UTILITIES ARE

BASED ON EXISTING RECORD DOCUMENTS ONLY, EXISTING

CONSTRUCTION CONDITIONS HAVE NOT BEEN FIELD VERIFIED.

1. VERIFY THAT CONSTRUCTION AND UTILITY ARRANGEMENTS

ARE AS SHOWN.

2. REPORT DISCREPANCIES TO THE ARCHITECTS BEFORE

DISTURBING EXISTING INSTALLATION.

3. BEGINNING OF ALTERATIONS WORK CONSTITUTES

ACCEPTANCE OF EXISTING CONDITIONS.

B. MAINTAIN WEATHERPROOF EXTERIOR BUILDING ENCLOSURE EXCEPT

FOR INTERRUPTIONS REQUIRED FOR REPLACEMENT OR

MODIFICATIONS, TAKE CARE TO PREVENT WATER AND HUMIDITY

DAMAGE.

1. WHERE OPENINGS IN EXTERIOR ENCLOSURE EXIST, PROVIDE

CONSTRUCTION TO MAKE EXTERIOR ENCLOSURE

WEATHERPROOF.

2. INSULATE EXISTING DUCTS OR PIPES THAT ARE EXPOSED TO

OUTDOOR AMBIENT TEMPERATURES BY ALTERATIONS WORK.

C. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO

ACCOMPLISH NEW WORK.

1. REMOVE ROTTED WOOD, CORRODED METALS, AND

DETERIORATED MASONRY AND CONCRETE, REPLACE WITH

NEW CONSTRUCTION SPECIFIED.

2. REMOVE ITEMS INDICATED ON DRAWINGS.

3. RELOCATE ITEMS INDICATED ON DRAWINGS.

4. WHERE NEW SURFACE FINISHES ARE TO BE APPLIED TO

EXISTING WORK, PERFORM REMOVALS, PATCH, AND PREPARE

EXISTING SURFACES AS REQUIRED TO RECEIVE NEW FINISH,

REMOVE EXISTING FINISH IF NECESSARY FOR SUCCESSFUL

APPLICATION OF NEW FINISH.

5. WHERE NEW SURFACE FINISHES ARE NOT SPECIFIED OR

INDICATED, PATCH HOLES AND DAMAGED SURFACES TO

MATCH ADJACENT FINISHED SURFACES AS CLOSELY AS

POSSIBLE.

D. SERVICES (INCLUDING BUT NOT LIMITED TO HVAC, PLUMBING,

ELECTRICAL, AND TELECOMMUNICATIONS): REMOVE, RELOCATE, AND

EXTEND EXISTING SYSTEMS TO ACCOMMODATE NEW CONSTRUCTION.

1. MAINTAIN EXISTING ACTIVE SYSTEMS THAT ARE TO REMAIN IN

OPERATION, MAINTAIN ACCESS TO EQUIPMENT AND

OPERATIONAL COMPONENTS, IF NECESSARY, MODIFY

INSTALLATION TO ALLOW ACCESS OR PROVIDE ACCESS PANEL.

2. WHERE EXISTING SYSTEMS OR EQUIPMENT ARE NOT ACTIVE

AND CONTRACT DOCUMENTS REQUIRE REACTIVATION, PUT

BACK INTO OPERATIONAL CONDITION, REPAIR SUPPLY,

DISTRIBUTION, AND EQUIPMENT AS REQUIRED.

3. WHERE EXISTING ACTIVE SYSTEMS SERVE OCCUPIED

FACILITIES BUT ARE TO BE REPLACED WITH NEW SERVICES,

MAINTAIN EXISTING SYSTEMS IN SERVICE UNTIL NEW SYSTEMS

ARE COMPLETE AND READY FOR SERVICE.

a. DISABLE EXISTING SYSTEMS ONLY TO MAKE

SWITCHOVERS AND CONNECTIONS, MINIMIZE DURATION

OF OUTAGES.

b. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED TO

MAINTAIN EXISTING SYSTEMS IN SERVICE.

4. VERIFY THAT ABANDONED SERVICES SERVE ONLY

ABANDONED FACILITIES.

5. REMOVE ABANDONED PIPE, DUCTS, CONDUITS, AND

EQUIPMENT, REMOVE BACK TO SOURCE OF SUPPLY WHERE

POSSIBLE, OTHERWISE CAP STUB AND TAG WITH

IDENTIFICATION, PATCH HOLES LEFT BY REMOVAL USING

MATERIALS SPECIFIED FOR NEW CONSTRUCTION.

E. PROTECT EXISTING WORK TO REMAIN.

1. PREVENT MOVEMENT OF STRUCTURE, PROVIDE SHORING AND

BRACING IF NECESSARY.

2. PERFORM CUTTING TO ACCOMPLISH REMOVALS NEATLY AND

AS SPECIFIED FOR CUTTING NEW WORK.

3. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED

DURING REMOVAL WORK.

4. PATCH AS SPECIFIED FOR PATCHING NEW WORK.

F. ADAPT EXISTING WORK TO FIT NEW WORK:

1. WHEN EXISTING FINISHED SURFACES ARE CUT SO THAT A

SMOOTH TRANSITION WITH NEW WORK IS NOT POSSIBLE,

TERMINATE EXISTING SURFACE ALONG A STRAIGHT LINE AT A

NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION TO

THE ARCHITECTS.

3.05 CUTTING AND PATCHING

A. EXECUTE CUTTING AND PATCHING INCLUDING EXCAVATION AND FILL

TO COMPLETE THE WORK, TO UNCOVER WORK IN ORDER TO INSTALL

IMPROPERLY SEQUENCED WORK, TO REMOVE AND REPLACE

DEFECTIVE OR NON-CONFORMING WORK, TO REMOVE SAMPLES OF

INSTALLED WORK FOR TESTING WHEN REQUESTED, TO PROVIDE

OPENINGS IN THE WORK FOR PENETRATION OF MECHANICAL AND

ELECTRICAL WORK, TO EXECUTE PATCHING TO COMPLEMENT

ADJACENT WORK, AND TO FIT PRODUCTS TOGETHER TO INTEGRATE

WITH OTHER WORK.

B. EXECUTE WORK BY METHODS TO AVOID DAMAGE TO OTHER WORK,

AND WHICH WILL PROVIDE APPROPRIATE SURFACES TO RECEIVE

PATCHING AND FINISHING. IN EXISTING WORK, MINIMIZE DAMAGE AND

RESTORE TO ORIGINAL CONDITION.

C. EMPLOY ORIGINAL INSTALLER TO PERFORM CUTTING FOR WEATHER

EXPOSED AND MOISTURE RESISTANT ELEMENTS, AND SIGHT

EXPOSED SURFACES.

D. CUT RIGID MATERIALS USING MASONRY SAW OR CORE DRILL.

PNEUMATIC TOOLS NOT ALLOWED WITHOUT PRIOR APPROVAL.

E. RESTORE WORK WITH NEW PRODUCTS IN ACCORDANCE WITH

REQUIREMENTS OF CONTRACT DOCUMENTS.

F. FIT WORK AIR TIGHT TO PIPES, SLEEVES, DUCTS, CONDUIT, AND

OTHER PENETRATIONS THROUGH SURFACES.

G. REFINISH SURFACES TO MATCH ADJACENT FINISH. FOR CONTINUOUS

SURFACES, REFINISH TO NEAREST INTERSECTION OR NATURAL

BREAK. FOR AN ASSEMBLY, REFINISH ENTIRE UNIT.

H. MAKE NEAT TRANSITIONS. PATCH WORK TO MATCH ADJACENT WORK

IN TEXTURE AND APPEARANCE. WHERE NEW WORK ABUTS OR

ALIGNS WITH EXISTING, PERFORM A SMOOTH AND EVEN TRANSITION.

3.06 PROGRESS CLEANING

A. MAINTAIN AREAS FREE OF WASTE MATERIALS, DEBRIS, AND RUBBISH.

MAINTAIN SITE IN A CLEAN AND ORDERLY CONDITION.

B. REMOVE DEBRIS AND RUBBISH FROM PIPE CHASES, PLENUMS,

ATTICS, CRAWL SPACES, AND OTHER CLOSED OR REMOTE SPACES,

PRIOR TO ENCLOSING THE SPACE.

C. BROOM AND VACUUM CLEAN INTERIOR AREAS PRIOR TO START OF

SURFACE FINISHING, AND CONTINUE CLEANING TO ELIMINATE DUST.

D. COLLECT AND REMOVE WASTE MATERIALS, DEBRIS, AND

TRASH/RUBBISH FROM SITE PERIODICALLY AND DISPOSE OFF-SITE,

DO NOT BURN OR BURY.

3.07 PROTECTION OF INSTALLED WORK

A. PROTECT INSTALLED WORK FROM DAMAGE BY CONSTRUCTION

OPERATIONS.

B. PROVIDE SPECIAL PROTECTION WHERE SPECIFIED IN INDIVIDUAL

SPECIFICATION SECTIONS.

C. PROVIDE TEMPORARY AND REMOVABLE PROTECTION FOR INSTALLED

PRODUCTS. CONTROL ACTIVITY IN IMMEDIATE WORK AREA TO

PREVENT DAMAGE.

D. PROVIDE PROTECTIVE COVERINGS AT WALLS, PROJECTIONS, JAMBS,

SILLS, AND SOFFITS OF OPENINGS.

E. PROTECT FINISHED FLOORS, STAIRS, AND OTHER SURFACES FROM

TRAFFIC, DIRT, WEAR, DAMAGE, OR MOVEMENT OF HEAVY OBJECTS,

BY PROTECTING WITH DURABLE SHEET MATERIALS.

F. PROHIBIT TRAFFIC OR STORAGE UPON WATERPROOFED OR ROOFED

SURFACES. IF TRAFFIC OR ACTIVITY IS NECESSARY, OBTAIN

RECOMMENDATIONS FOR PROTECTION FROM WATERPROOFING OR

ROOFING MATERIAL MANUFACTURER.

G. REMOVE PROTECTIVE COVERINGS WHEN NO LONGER NEEDED,

REUSE OR RECYCLE PLASTIC COVERINGS IF POSSIBLE.

3.08 STARTING SYSTEMS

A. COORDINATE SCHEDULE FOR START-UP OF VARIOUS EQUIPMENT AND

SYSTEMS.

B. VERIFY THAT EACH PIECE OF EQUIPMENT OR SYSTEM HAS BEEN

CHECKED FOR PROPER LUBRICATION, DRIVE ROTATION, BELT

TENSION, CONTROL SEQUENCE, AND FOR CONDITIONS WHICH MAY

CAUSE DAMAGE.

C. VERIFY TESTS, METER READINGS, AND SPECIFIED ELECTRICAL

CHARACTERISTICS AGREE WITH THOSE REQUIRED BY THE

EQUIPMENT OR SYSTEM MANUFACTURER.

D. VERIFY THAT WIRING AND SUPPORT COMPONENTS FOR EQUIPMENT

ARE COMPLETE AND TESTED.

E. EXECUTE START-UP UNDER SUPERVISION OF APPLICABLE

PERSONNEL AND MANUFACTURER'S REPRESENTATIVE IN

ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS.

F. SUBMIT A WRITTEN REPORT THAT EQUIPMENT OR SYSTEM HAS BEEN

PROPERLY INSTALLED AND IS FUNCTIONING CORRECTLY.

3.09 DEMONSTRATION AND INSTRUCTION

A. DEMONSTRATE START-UP, OPERATION, CONTROL, ADJUSTMENT,

TROUBLE-SHOOTING, SERVICING, MAINTENANCE, AND SHUTDOWN OF

EACH ITEM OF EQUIPMENT AT SCHEDULED TIME, AT EQUIPMENT

LOCATION.

B. FOR EQUIPMENT OR SYSTEMS REQUIRING SEASONAL OPERATION,

PERFORM DEMONSTRATION FOR OTHER SEASON WITHIN SIX MONTHS.

C. PROVIDE A QUALIFIED PERSON WHO IS KNOWLEDGEABLE ABOUT THE

PROJECT TO PERFORM DEMONSTRATION AND INSTRUCTION OF

OWNER PERSONNEL.

3.10 ADJUSTING

A. ADJUST OPERATING PRODUCTS AND EQUIPMENT TO ENSURE

SMOOTH AND UNHINDERED OPERATION.

3.11 FINAL CLEANING

A. EXECUTE FINAL CLEAN UP PRIOR TO SUBSTANTIAL COMPLETION.

CLEANUP SHALL INCLUDE BUILDING AREA, CONSTRUCTION AREA

WITHIN WORK LIMITS AND CONSTRUCTION ACCESS ROUTES.

B. USE CLEANING MATERIALS THAT ARE NON-HAZARDOUS.

C. CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO

VIEW, REMOVE TEMPORARY LABELS, STAINS AND FOREIGN

SUBSTANCES, POLISH TRANSPARENT AND GLOSSY SURFACES, WIPE

GYPSUM BOARD WALLS READY FOR TENANT PAINT FINISH, BROOM

CLEAN INTERIOR FLOOR SLAB

D. CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH

CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL

BEING CLEANED.

E. CLEAN FILTERS OF OPERATING EQUIPMENT.

F. CLEAN DEBRIS FROM ROOFS, DOWNSPOUTS, AND DRAINAGE

SYSTEMS.

G. CLEAN SITE, SWEEP PAVED AREAS, RAKE CLEAN LANDSCAPED

SURFACES.

H. REMOVE WASTE, SURPLUS MATERIALS, TRASH/RUBBISH, AND

CONSTRUCTION FACILITIES FROM THE SITE, DISPOSE OF IN LEGAL

MANNER, DO NOT BURN OR BURY.

3.12 CLOSEOUT PROCEDURES

A. MAKE SUBMITTALS THAT ARE REQUIRED BY GOVERNING OR OTHER

AUTHORITIES.

1. PROVIDE COPIES TO THE ARCHITECTS AND THE OWNER.

B. NOTIFY THE ARCHITECTS AND THE OWNER WHEN WORK IS

CONSIDERED READY FOR SUBSTANTIAL COMPLETION.

C. SUBMIT WRITTEN CERTIFICATION THAT CONTRACT DOCUMENTS HAVE

BEEN REVIEWED, WORK HAS BEEN INSPECTED, AND THAT WORK IS

COMPLETE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND

READY FOR THE ARCHITECTS'S AND THE OWNER'S REVIEW.

D. CORRECT ITEMS OF WORK LISTED IN EXECUTED CERTIFICATES OF

SUBSTANTIAL COMPLETION AND COMPLY WITH REQUIREMENTS FOR

ACCESS TO THE OWNER-OCCUPIED AREAS.

E. NOTIFY THE ARCHITECTS AND THE OWNER WHEN WORK IS

CONSIDERED FINALLY COMPLETE.

F. COMPLETE ITEMS OF WORK DETERMINED BY THE ARCHITECTS'S AND

THE OWNER'S FINAL INSPECTION.

END OF SECTION

SECTION 017700 - CLOSEOUT SUBMITTALS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. PROJECT RECORD DOCUMENTS.

B. OPERATION AND MAINTENANCE DATA.

C. WARRANTIES AND BONDS.

1.02 RELATED SECTIONS

A. SECTION 013000 - ADMINISTRATIVE REQUIREMENTS: SUBMITTALS

PROCEDURES, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. INDIVIDUAL PRODUCT SECTIONS: SPECIFIC REQUIREMENTS FOR

OPERATION AND MAINTENANCE DATA.

C. INDIVIDUAL PRODUCT SECTIONS: WARRANTIES REQUIRED FOR

SPECIFIC PRODUCTS OR WORK.

1.03 SUBMITTALS

A. PROJECT RECORD DOCUMENTS: SUBMIT DOCUMENTS TO THE

ARCHITECTS WITH CLAIM FOR FINAL APPLICATION FOR PAYMENT.

B. OPERATION AND MAINTENANCE DATA:

1. SUBMIT TWO COPIES OF PRELIMINARY DRAFT OR PROPOSED

FORMATS AND OUTLINES OF CONTENTS BEFORE START OF

WORK. THE ARCHITECTS WILL REVIEW DRAFT AND RETURN

ONE COPY WITH COMMENTS.

2. SUBMIT 1 COPY OF COMPLETED DOCUMENTS 15 DAYS PRIOR

TO FINAL INSPECTION. THIS COPY WILL BE REVIEWED AND

RETURNED AFTER FINAL INSPECTION, WITH THE ARCHITECTS

COMMENTS. REVISE CONTENT OF ALL DOCUMENT SETS AS

REQUIRED PRIOR TO FINAL SUBMISSION.

3. SUBMIT TWO SETS OF REVISED FINAL DOCUMENTS IN FINAL

FORM WITHIN 10 DAYS AFTER FINAL INSPECTION.

C. WARRANTIES AND BONDS:

1. FOR EQUIPMENT OR COMPONENT PARTS OF EQUIPMENT PUT

INTO SERVICE DURING CONSTRUCTION WITH THE OWNER'S

PERMISSION, SUBMIT DOCUMENTS WITHIN TEN DAYS AFTER

ACCEPTANCE.

2. MAKE OTHER SUBMITTALS WITHIN TEN DAYS AFTER DATE OF

SUBSTANTIAL COMPLETION, PRIOR TO FINAL APPLICATION FOR

PAYMENT.

3. FOR ITEMS OF WORK FOR WHICH ACCEPTANCE IS DELAYED

BEYOND DATE OF SUBSTANTIAL COMPLETION, SUBMIT WITHIN

TEN DAYS AFTER ACCEPTANCE, LISTING THE DATE OF

ACCEPTANCE AS THE BEGINNING OF THE WARRANTY PERIOD.

PART 3 EXECUTION

3.01 PROJECT RECORD DOCUMENTS

A. MAINTAIN ON SITE ONE SET OF THE FOLLOWING RECORD

DOCUMENTS, RECORD ACTUAL REVISIONS TO THE WORK:

1. DRAWINGS.

2. SPECIFICATIONS.

3. ADDENDA.

4. CHANGE ORDERS AND OTHER MODIFICATIONS TO THE

CONTRACT.

5. REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

6. MANUFACTURER'S INSTRUCTION FOR ASSEMBLY,

INSTALLATION, AND ADJUSTING.

B. ENSURE ENTRIES ARE COMPLETE AND ACCURATE, ENABLING FUTURE

REFERENCE BY THE OWNER.

C. STORE RECORD DOCUMENTS SEPARATE FROM DOCUMENTS USED

FOR CONSTRUCTION.

D. RECORD INFORMATION CONCURRENT WITH CONSTRUCTION

PROGRESS.

E. SPECIFICATIONS: LEGIBLY MARK AND RECORD AT EACH PRODUCT

SECTION DESCRIPTION OF ACTUAL PRODUCTS INSTALLED, INCLUDING

THE FOLLOWING:

1. MANUFACTURER'S NAME AND PRODUCT MODEL AND NUMBER.

2. PRODUCT SUBSTITUTIONS OR ALTERNATES UTILIZED.

3. CHANGES MADE BY ADDENDA AND MODIFICATIONS.

F. RECORD DRAWINGS AND SHOP DRAWINGS: LEGIBLY MARK EACH ITEM

TO RECORD ACTUAL CONSTRUCTION INCLUDING:

1. MEASURED DEPTHS OF FOUNDATIONS IN RELATION TO FINISH

FIRST FLOOR DATUM.

2. MEASURED HORIZONTAL AND VERTICAL LOCATIONS OF

UNDERGROUND UTILITIES AND APPURTENANCES,

REFERENCED TO PERMANENT SURFACE IMPROVEMENTS.

3. MEASURED LOCATIONS OF INTERNAL UTILITIES AND

APPURTENANCES CONCEALED IN CONSTRUCTION,

REFERENCED TO VISIBLE AND ACCESSIBLE FEATURES OF THE

WORK.

4. FIELD CHANGES OF DIMENSION AND DETAIL.

5. DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS.

3.02 OPERATION AND MAINTENANCE DATA

A. FOR EACH PRODUCT OR SYSTEM: LIST NAMES, ADDRESSES AND

TELEPHONE NUMBERS OF SUBCONTRACTORS AND SUPPLIERS,

INCLUDING LOCAL SOURCE OF SUPPLIES AND REPLACEMENT PARTS.

B. TYPED TEXT: AS REQUIRED TO SUPPLEMENT PRODUCT DATA.

PROVIDE LOGICAL SEQUENCE OF INSTRUCTIONS FOR EACH

PROCEDURE, INCORPORATING MANUFACTURER'S INSTRUCTIONS.

3.03 OPERATION AND MAINTENANCE DATA FOR EQUIPMENT AND SYSTEMS

A. FOR EACH ITEM OF EQUIPMENT AND EACH SYSTEM:

1. DESCRIPTION OF UNIT OR SYSTEM, AND COMPONENT PARTS.

2. IDENTIFY FUNCTION, NORMAL OPERATING CHARACTERISTICS,

AND LIMITING CONDITIONS.

3. INCLUDE PERFORMANCE CURVES, WITH ENGINEERING DATA

AND TESTS.

4. COMPLETE NOMENCLATURE AND MODEL NUMBER OF

REPLACEABLE PARTS.

B. OPERATING PROCEDURES: INCLUDE START-UP, BREAK-IN, AND

ROUTINE NORMAL OPERATING INSTRUCTIONS AND SEQUENCES.

INCLUDE REGULATION, CONTROL, STOPPING, SHUT-DOWN, AND

EMERGENCY INSTRUCTIONS. INCLUDE SUMMER, WINTER, AND ANY

SPECIAL OPERATING INSTRUCTIONS.

C. MAINTENANCE REQUIREMENTS: INCLUDE ROUTINE PROCEDURES

AND GUIDE FOR PREVENTATIVE MAINTENANCE AND TROUBLE

SHOOTING, DISASSEMBLY, REPAIR, AND REASSEMBLY INSTRUCTIONS,

AND ALIGNMENT, ADJUSTING, BALANCING, AND CHECKING

INSTRUCTIONS.

D. PROVIDE SERVICING AND LUBRICATION SCHEDULE, AND LIST OF

LUBRICANTS REQUIRED.

E. INCLUDE MANUFACTURER'S PRINTED OPERATION AND MAINTENANCE

INSTRUCTIONS.

F. INCLUDE SEQUENCE OF OPERATION BY CONTROLS MANUFACTURER.

G. PROVIDE ORIGINAL MANUFACTURER'S PARTS LIST, ILLUSTRATIONS,

ASSEMBLY DRAWINGS, AND DIAGRAMS REQUIRED FOR MAINTENANCE.

H. ADDITIONAL REQUIREMENTS: AS SPECIFIED IN INDIVIDUAL PRODUCT

SPECIFICATION SECTIONS.

3.04 OPERATION AND MAINTENANCE MANUALS

A. PREPARE INSTRUCTIONS AND DATA BY PERSONNEL EXPERIENCED IN

MAINTENANCE AND OPERATION OF DESCRIBED PRODUCTS.

B. PREPARE DATA IN THE FORM OF AN INSTRUCTIONAL MANUAL.

C. BINDERS: COMMERCIAL QUALITY, 8-1/2 X 11 INCH (216 X 280 MM)

THREE D SIDE RING BINDERS WITH DURABLE PLASTIC COVERS, 2 INCH

(50 MM) MAXIMUM RING SIZE. WHEN MULTIPLE BINDERS ARE USED,

CORRELATE DATA INTO RELATED CONSISTENT GROUPINGS.

D. PROVIDE TABBED DIVIDERS FOR EACH SEPARATE PRODUCT AND

SYSTEM, WITH TYPED DESCRIPTION OF PRODUCT AND MAJOR

COMPONENT PARTS OF EQUIPMENT.

3.05 WARRANTIES AND BONDS

A. OBTAIN WARRANTIES AND BONDS, EXECUTED IN DUPLICATE BY

RESPONSIBLE SUBCONTRACTORS, SUPPLIERS, AND

MANUFACTURERS, WITHIN TEN DAYS AFTER COMPLETION OF THE

APPLICABLE ITEM OF WORK. EXCEPT FOR ITEMS PUT INTO USE WITH

THE OWNER'S PERMISSION, LEAVE DATE OF BEGINNING OF TIME OF

WARRANTY UNTIL THE DATE OF SUBSTANTIAL COMPLETION IS

DETERMINED.

B. VERIFY THAT DOCUMENTS ARE IN PROPER FORM, CONTAIN FULL

INFORMATION, AND ARE NOTARIZED.

C. CO-EXECUTE SUBMITTALS WHEN REQUIRED.

D. RETAIN WARRANTIES AND BONDS UNTIL TIME SPECIFIED FOR

SUBMITTAL.

END OF SECTION

SECTION 022000 - SITE PREPARATION

PART 1 GENERAL

1.01 SECTION INCLUDES

A. BUILDING DEMOLITION.

B. SELECTIVE DEMOLITION OF BUILT SITE ELEMENTS.

C. ABANDONMENT AND REMOVAL OF EXISTING UTILITIES AND UTILITY

STRUCTURES.

1.02 REFERENCES

A. 29 CFR 1926 - U.S. OCCUPATIONAL SAFETY AND HEALTH STANDARDS,

CURRENT EDITION.

B. NFPA 241 - STANDARD FOR SAFEGUARDING CONSTRUCTION,

ALTERATION, AND DEMOLITION OPERATIONS, 2000.

1.03 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL

LOCATIONS OF CAPPED AND ACTIVE UTILITIES AND SUBSURFACE

CONSTRUCTION.

1.04 PROJECT CONDITIONS

A. MINIMIZE PRODUCTION OF DUST DUE TO DEMOLITION OPERATIONS,

DO NOT USE WATER IF THAT WILL RESULT IN ICE, FLOODING,

SEDIMENTATION OF PUBLIC WATERWAYS OR STORM SEWERS, OR

OTHER POLLUTION.

B. COMPLY WITH OTHER REQUIREMENTS SPECIFIED IN SECTION 017300.

PART 2 PRODUCTS

2.01 MATERIALS

A. FILL MATERIAL: AS SPECIFIED IN SECTION 02315 - FILL AND BACKFILL

PART 3 EXECUTION

3.01 EXISTING UTILITIES

A. COORDINATE WORK WITH UTILITY COMPANIES, NOTIFY BEFORE

STARTING WORK AND COMPLY WITH THEIR REQUIREMENTS, OBTAIN

REQUIRED PERMITS.

B. PROTECT EXISTING UTILITIES TO REMAIN FROM DAMAGE.

C. DO NOT DISRUPT PUBLIC UTILITIES WITHOUT PERMIT FROM

AUTHORITY HAVING JURISDICTION.

D. DO NOT CLOSE, SHUT OFF, OR DISRUPT EXISTING LIFE SAFETY

SYSTEMS THAT ARE IN USE WITHOUT PRIOR WRITTEN NOTIFICATION

TO THE OWNER.

E. DO NOT CLOSE, SHUT OFF, OR DISRUPT EXISTING UTILITY BRANCHES

OR TAKE-OFFS THAT ARE IN USE WITHOUT PRIOR WRITTEN

NOTIFICATION TO THE OWNER.

F. LOCATE AND MARK UTILITIES TO REMAIN, MARK USING HIGHLY

VISIBLE TAGS OR FLAGS, WITH IDENTIFICATION OF UTILITY TYPE,

PROTECT FROM DAMAGE DUE TO SUBSEQUENT CONSTRUCTION,

USING SUBSTANTIAL BARRICADES IF NECESSARY.

G. REMOVE EXPOSED PIPING, VALVES, METERS, EQUIPMENT, SUPPORTS,

AND FOUNDATIONS OF DISCONNECTED AND ABANDONED UTILITIES.

H. PREPARE BUILDING DEMOLITION AREAS BY DISCONNECTING AND

CAPPING UTILITIES OUTSIDE THE DEMOLITION ZONE, IDENTIFY AND

MARK UTILITIES TO BE SUBSEQUENTLY RECONNECTED, IN SAME

MANNER AS OTHER UTILITIES TO REMAIN.

3.02 EXISTING BUILT ELEMENTS

A. SCOPE:

1. REMOVE THE BUILDING CONSTRUCTION WHERE REQUIRED TO

ACCOMMODATE NEW BUILDING CONSTRUCTION.

2. REMOVE OTHER ITEMS INDICATED, FOR SALVAGE AND REUSE

AND REINSTALLATION.

3. FILL EXCAVATIONS, OPEN PITS, AND HOLES IN GROUND AREAS

GENERATED AS RESULT OF REMOVALS, USING SPECIFIED FILL,

COMPACT FILL AS REQUIRED SO THAT REQUIRED ROUGH

GRADE ELEVATIONS DO NOT SUBSIDE WITHIN ONE YEAR

AFTER COMPLETION.

B. COMPLY WITH APPLICABLE CODES AND REGULATIONS FOR

DEMOLITION OPERATIONS AND SAFETY OF ADJACENT STRUCTURES

AND THE PUBLIC.

1. OBTAIN REQUIRED PERMITS.

2. COMPLY WITH APPLICABLE REQUIREMENTS OF NFPA 241.

3. USE OF EXPLOSIVES IS NOT PERMITTED.

4. TAKE PRECAUTIONS TO PREVENT CATASTROPHIC OR

UNCONTROLLED COLLAPSE OF STRUCTURES TO BE REMOVED,

DO NOT ALLOW WORKER OR PUBLIC ACCESS WITHIN RANGE

OF POTENTIAL COLLAPSE OF UNSTABLE STRUCTURES.

5. PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS AND

SECURITY DEVICES.

6. USE PHYSICAL BARRIERS TO PREVENT ACCESS TO AREAS

THAT COULD BE HAZARDOUS TO WORKERS OR THE PUBLIC.

7. CONDUCT OPERATIONS TO MINIMIZE EFFECTS ON AND

INTERFERENCE WITH ADJACENT STRUCTURES AND

OCCUPANTS.

8. DO NOT CLOSE OR OBSTRUCT ROADWAYS OR SIDEWALKS

WITHOUT PERMIT.

9. CONDUCT OPERATIONS TO MINIMIZE OBSTRUCTION OF PUBLIC

AND PRIVATE ENTRANCES AND EXITS, DO NOT OBSTRUCT

REQUIRED EXITS AT ANY TIME, PROTECT PERSONS USING

ENTRANCES AND EXITS FROM REMOVAL OPERATIONS.

10. OBTAIN WRITTEN PERMISSION FROM OWNERS OF ADJACENT

PROPERTIES WHEN DEMOLITION EQUIPMENT WILL TRAVERSE,

INFRINGE UPON OR LIMIT ACCESS TO THEIR PROPERTY.

C. PROTECT EXISTING STRUCTURES AND OTHER ELEMENTS THAT ARE

NOT TO BE REMOVED.

1. PROVIDE BRACING AND SHORING.

2. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT

STRUCTURES.

3. STOP WORK IMMEDIATELY IF ADJACENT STRUCTURES APPEAR

TO BE IN DANGER.

D. IF HAZARDOUS MATERIALS ARE DISCOVERED DURING REMOVAL

OPERATIONS, STOP WORK AND NOTIFY THE ARCHITECTS AND THE

OWNER, HAZARDOUS MATERIALS INCLUDE REGULATED ASBESTOS

CONTAINING MATERIALS, LEAD, PCB'S, AND MERCURY.

E. PARTIAL REMOVAL OF PAVING AND CURBS: NEATLY SAW CUT AT

RIGHT ANGLE TO SURFACE.

3.03 DEBRIS

A. REMOVE DEBRIS, JUNK, AND TRASH FROM SITE.

3.04 WASTE REMOVAL

A. REMOVE FROM SITE ALL MATERIALS NOT TO BE REUSED ON SITE, DO

NOT BURN OR BURY.

B. LEAVE SITE IN CLEAN CONDITION, READY FOR SUBSEQUENT WORK.

C. CLEAN UP SPILLAGE AND WIND-BLOWN DEBRIS FROM PUBLIC AND

PRIVATE LANDS.

END OF SECTION

SECTION 02315 - FILL AND BACKFILL

PART 1 GENERAL

1.01 SECTION INCLUDES

A. APPROPRIATE BACKFILL AND FILL MATERIAL FOR SITE PREPARATION

PART 2 PRODUCTS

2.01 BACKFILL

A. SUITABLE MATERIAL SHALL BE FREE OF LARGE LUMPS OR CLODS,

WHICH WILL NOT READILY BREAK DOWN UNDER COMPACTION.

B. SHALL BE FREE OF VEGETATION OR OTHER EXTRANEOUS MATERIAL.

C. MAY BE SUBJECT TO APPROVAL BY THE ENGINEER

2.02 TOPSOIL

D. TOP 3" OF FINISH EARTH GRADE SHALL BE TOP SOIL WITH NO

EXCESSIVE CLODS.

END OF SECTION

SECTION 024100 - DEMOLITION

PART 1 GENERAL

1.01 DESCRIPTION

A. THIS SECTION SPECIFIES DEMOLITION AND REMOVAL OF WALK,

CURBS, SLABS, PORTIONS OF BUILDINGS, UTILITIES, OTHER

STRUCTURES FROM BUILDING

1.02 PROTECTION

A. PERFORM DEMOLITION IN SUCH MANNER AS TO ELIMINATE HAZARDS

TO PERSONS AND PROPERTY; TO MINIMIZE INTERFERENCE WITH USE

OF ADJACENT AREAS, UTILITIES AND STRUCTURES OR INTERRUPTION

OF USE OF SUCH UTILITIES; AND TO PROVIDE FREE PASSAGE TO AND

FROM SUCH ADJACENT AREAS OF STRUCTURES. COMPLY WITH

REQUIREMENTS OF GENERAL CONDITIONS ARTICLE, ACCIDENT

PREVENTION.

B. PROVIDE SAFEGUARDS, INCLUDING WARNING SIGNS, BARRICADES,

TEMPORARY FENCES, WARNING LIGHTS, AND OTHER SIMILAR ITEMS

THAT ARE REQUIRED FOR PROTECTION OF ALL PERSONNEL DURING

DEMOLITION AND REMOVAL OPERATIONS.

C. MAINTAIN FENCES, BARRICADES, LIGHTS, AND OTHER SIMILAR ITEMS

AROUND EXPOSED EXCAVATIONS UNTIL SUCH EXCAVATIONS HAVE

BEEN COMPLETELY FILLED.

D. PREVENT SPREAD OF FLYING PARTICLES AND DUST. KEEP DUST TO A

MINIMUM.

E. LOCAL FIRE AND SAFETY RULES TO BE OBSERVED IN PERFORMANCE

OF WORK, INCLUDE FOLLOWING:

1. WHEREVER A CUTTING TORCH OR OTHER EQUIPMENT THAT

MIGHT CAUSE A FIRE IS USED, PROVIDE AND MAINTAIN FIRE

EXTINGUISHERS NEARBY READY FOR IMMEDIATE USE.

INSTRUCT ALL POSSIBLE USERS IN USE OF FIRE

EXTINGUISHERS.

2. KEEP HYDRANTS CLEAR AND ACCESSIBLE AT ALL TIMES.

PROHIBIT DEBRIS FROM ACCUMULATING WITHIN A RADIUS OF

4500 MM (15 FEET) OF FIRE HYDRANTS.

F. BEFORE BEGINNING ANY DEMOLITION WORK, THE CONTRACTOR

SHALL SURVEY THE SITE AND EXAMINE THE DRAWINGS AND

SPECIFICATIONS TO DETERMINE THE EXTENT OF THE WORK. THE

CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO AVOID

DAMAGES TO EXISTING ITEMS TO REMAIN IN PLACE, TO BE REUSED,

OR TO REMAIN THE PROPERTY OF THE TENANT OR LANDLORD. THE

CONTRACTOR SHALL COORDINATE THE WORK OF THIS SECTION WITH

ALL OTHER WORK AND SHALL CONSTRUCT AND MAINTAIN SHORING,

BRACING, AND SUPPORTS AS REQUIRED. THE CONTRACTOR SHALL

ENSURE THAT STRUCTURAL ELEMENTS ARE NOT OVERLOADED AND

SHALL BE RESPONSIBLE FOR INCREASING STRUCTURAL SUPPORTS

OR ADDING NEW SUPPORTS AS MAY BE REQUIRED AS A RESULT OF

ANY CUTTING, REMOVAL, OR DEMOLITION WORK PERFORMED UNDER

THIS CONTRACT. DO NOT OVERLOAD STRUCTURAL ELEMENTS.

PROVIDE NEW SUPPORTS AND REINFORCEMENT FOR EXISTING

CONSTRUCTION WEAKENED BY DEMOLITION OR REMOVAL WORKS.

REPAIRS, REINFORCEMENT, OR STRUCTURAL REPLACEMENT MUST

HAVE RESIDENT ENGINEER'S APPROVAL.

1.03 UTILITY SERVICES

A. DEMOLISH AND REMOVE OUTSIDE UTILITY SERVICE LINES SHOWN TO

BE REMOVED.

B. REMOVE ABANDONED UTILITY LINES THAT WOULD INTERFERE WITH

INSTALLATION OF NEW UTILITY LINES AND NEW CONSTRUCTION.

PART 2 PRODUCTS (NOT USED)

PART 3 EXECUTION

3.01 DEMOLITION

A. DEBRIS, INCLUDING BRICK, CONCRETE, STONE, METALS AND SIMILAR

MATERIALS SHALL BECOME PROPERTY OF CONTRACTOR AND SHALL

BE DISPOSED OF BY HIM DAILY TO AVOID ACCUMULATION AT THE

DEMOLITION SITE. MATERIALS THAT CANNOT BE REMOVED DAILY

SHALL BE STORED IN AREAS SPECIFIED BY LANDLORD. BREAK UP

CONCRETE SLABS BELOW GRADE THAT DO NOT REQUIRE REMOVAL

FROM PRESENT LOCATION INTO PIECES NOT EXCEEDING 600 MM (24

INCHES) SQUARE TO PERMIT DRAINAGE. CONTRACTOR SHALL

DISPOSE DEBRIS IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE

OR LOCAL PERMITS, RULES AND/OR REGULATIONS.

B. REMOVE AND LEGALLY DISPOSE OF ALL MATERIALS, FROM ANY

TRASH DUMPS ON SITE. MATERIALS REMOVED SHALL BECOME

PROPERTY OF CONTRACTOR AND SHALL BE DISPOSED OF IN

COMPLIANCE WITH APPLICABLE FEDERAL, STATE OR LOCAL PERMITS,

RULES AND/OR REGULATIONS.

3.02 CLEAN UP

A. ON COMPLETION OF WORK OF THIS SECTION AND AFTER REMOVAL OF

ALL DEBRIS, LEAVE SITE IN CLEAN CONDITION SATISFACTORY TO

START CONSTRUCTION OF TENANT PROPERTY.

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.1

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.1

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 8: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 033000 - CAST-IN-PLACE CONCRETE

PART 1 - GENERAL

1.01 SUMMARY

A. THIS SECTION SPECIFIES CAST-IN PLACE CONCRETE, INCLUDING

FORMWORK, REINFORCEMENT, CONCRETE MATERIALS, MIXTURE

DESIGN, PLACEMENT PROCEDURES, AND FINISHES.

1.02 QUALITY ASSURANCE

A. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN

MANUFACTURING READY-MIXED CONCRETE PRODUCTS AND THAT

COMPLIES WITH ASTM C 94/C 94M REQUIREMENTS FOR PRODUCTION

FACILITIES AND EQUIPMENT.

1. MANUFACTURER CERTIFIED ACCORDING TO NRMCA'S

"CERTIFICATION OF READY MIXED CONCRETE PRODUCTION

FACILITIES."

B. ACI PUBLICATIONS: COMPLY WITH THE FOLLOWING UNLESS MODIFIED

BY REQUIREMENTS IN THE CONTRACT DOCUMENTS:

1. ACI 301, "SPECIFICATION FOR STRUCTURAL CONCRETE,"

SECTIONS 1 THROUGH 5.

2. ACI 117, "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE

CONSTRUCTION AND MATERIALS."

PART 2 - PRODUCTS

2.01 STEEL REINFORCEMENT

A. REINFORCING BARS: ASTM A 615/A 615M, GRADE 60, DEFORMED.

B. PLAIN-STEEL WELDED WIRE REINFORCEMENT: ASTM A 185, PLAIN,

FABRICATED FROM AS-DRAWN STEEL WIRE INTO FLAT SHEETS.

C. BAR SUPPORTS: BOLSTERS, CHAIRS, SPACERS, AND OTHER DEVICES

FOR SPACING, SUPPORTING, AND FASTENING REINFORCING BARS

AND WELDED WIRE REINFORCEMENT IN PLACE. MANUFACTURE BAR

SUPPORTS FROM STEEL WIRE, PLASTIC, OR PRECAST CONCRETE

ACCORDING TO CRSI'S "MANUAL OF STANDARD PRACTICE."

2.02 CONCRETE MATERIALS

A. CEMENTITIOUS MATERIAL: USE THE FOLLOWING CEMENTITIOUS

MATERIALS, OF THE SAME TYPE, BRAND, AND SOURCE, THROUGHOUT

PROJECT:

1. PORTLAND CEMENT: ASTM C 150, TYPE I.

B. NORMAL-WEIGHT AGGREGATES: ASTM C 33, GRADED, 1-INCH (25-MM)

NOMINAL MAXIMUM COARSE-AGGREGATE SIZE.

1. FINE AGGREGATE: FREE OF MATERIALS WITH DELETERIOUS

REACTIVITY TO ALKALI IN CEMENT.

C. WATER: ASTM C 94/C 94M AND POTABLE.

D. AIR-ENTRAINING ADMIXTURE: ASTM C 260.

E. CHEMICAL ADMIXTURES: PROVIDE ADMIXTURES CERTIFIED BY

MANUFACTURER TO BE COMPATIBLE WITH OTHER ADMIXTURES AND

THAT WILL NOT CONTRIBUTE WATER-SOLUBLE CHLORIDE IONS

EXCEEDING THOSE PERMITTED IN HARDENED CONCRETE. DO NOT

USE CALCIUM CHLORIDE OR ADMIXTURES CONTAINING CALCIUM

CHLORIDE.

1. WATER-REDUCING ADMIXTURE: ASTM C 494/C 494M, TYPE A.

2. RETARDING ADMIXTURE: ASTM C 494/C 494M, TYPE B.

3. WATER-REDUCING AND RETARDING ADMIXTURE: ASTM C 494/C

494M, TYPE D.

4. HIGH-RANGE, WATER-REDUCING ADMIXTURE: ASTM C 494/C

494M, TYPE F.

5. HIGH-RANGE, WATER-REDUCING AND RETARDING ADMIXTURE:

ASTM C 494/C 494M, TYPE G.

6. PLASTICIZING AND RETARDING ADMIXTURE: ASTM C 1017/C

1017M, TYPE II.

2.03 VAPOR RETARDERS

A. PLASTIC VAPOR RETARDER: ASTM E 1745, CLASS B. INCLUDE

MANUFACTURER'S RECOMMENDED ADHESIVE OR

PRESSURE-SENSITIVE TAPE.

2.04 CURING MATERIALS

A. EVAPORATION RETARDER: WATERBORNE, MONOMOLECULAR FILM

FORMING, MANUFACTURED FOR APPLICATION TO FRESH CONCRETE.

B. ABSORPTIVE COVER: AASHTO M 182, CLASS 2, BURLAP CLOTH MADE

FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9 OZ./SQ. YD. (305

G/SQ. M) WHEN DRY.

C. MOISTURE-RETAINING COVER: ASTM C 171, POLYETHYLENE FILM OR

WHITE BURLAP-POLYETHYLENE SHEET.

D. WATER: POTABLE.

2.05 RELATED MATERIALS

A. EXPANSION- AND ISOLATION-JOINT-FILLER STRIPS: ASTM D 1751,

ASPHALT-SATURATED CELLULOSIC FIBER.

2.06 CONCRETE MIXTURES

A. PREPARE DESIGN MIXTURES FOR EACH TYPE AND STRENGTH OF

CONCRETE, PROPORTIONED ON THE BASIS OF LABORATORY TRIAL

MIXTURE OR FIELD TEST DATA, OR BOTH, ACCORDING TO ACI 301.

B. PROPORTION NORMAL-WEIGHT CONCRETE MIXTURE AS FOLLOWS:

1. MINIMUM COMPRESSIVE STRENGTH: 3000 PSI (27.6 MPA) AT 28

DAYS.

2. MAXIMUM WATER-CEMENTITIOUS MATERIALS RATIO: 0.45.

3. SLUMP LIMIT: 5 INCHES (125 MM), PLUS OR MINUS 1 INCH (25

MM).

4. AIR CONTENT: 6 PERCENT, PLUS OR MINUS 1.5 PERCENT AT

POINT OF DELIVERY FOR 1-INCH (25-MM) NOMINAL MAXIMUM

AGGREGATE SIZE.

5. AIR CONTENT: DO NOT ALLOW AIR CONTENT OF TROWELED

FINISHED FLOORS TO EXCEED 3 PERCENT.

PART 3 - EXECUTION

3.01 FORMWORK

A. DESIGN, ERECT, SHORE, BRACE, AND MAINTAIN FORMWORK

ACCORDING TO ACI 301 TO SUPPORT VERTICAL, LATERAL, STATIC,

AND DYNAMIC LOADS, AND CONSTRUCTION LOADS THAT MIGHT BE

APPLIED, UNTIL STRUCTURE CAN SUPPORT SUCH LOADS.

3.02 STEEL REINFORCEMENT

A. GENERAL: COMPLY WITH CRSI'S "MANUAL OF STANDARD PRACTICE"

FOR PLACING REINFORCEMENT.

1. DO NOT CUT OR PUNCTURE VAPOR RETARDER. REPAIR

DAMAGE AND RESEAL VAPOR RETARDER BEFORE PLACING

CONCRETE.

3.03 JOINTS

A. GENERAL: CONSTRUCT JOINTS TRUE TO LINE WITH FACES

PERPENDICULAR TO SURFACE PLANE OF CONCRETE.

B. CONSTRUCTION JOINTS: INSTALL SO STRENGTH AND APPEARANCE

OF CONCRETE ARE NOT IMPAIRED, AT LOCATIONS INDICATED OR AS

APPROVED BY ARCHITECT.

C. CONTRACTION JOINTS IN SLABS-ON-GRADE: FORM WEAKENED-PLANE

CONTRACTION JOINTS, SECTIONING CONCRETE INTO AREAS AS

INDICATED. CONSTRUCT CONTRACTION JOINTS FOR A DEPTH EQUAL

TO AT LEAST ONE-FOURTH OF CONCRETE THICKNESS AS FOLLOWS:

1. GROOVED JOINTS: FORM CONTRACTION JOINTS AFTER INITIAL

FLOATING BY GROOVING AND FINISHING EACH EDGE OF JOINT

TO A RADIUS OF 1/8 INCH (3.2 MM). REPEAT GROOVING OF

CONTRACTION JOINTS AFTER APPLYING SURFACE FINISHES.

ELIMINATE GROOVER TOOL MARKS ON CONCRETE SURFACES.

2. SAWED JOINTS: FORM CONTRACTION JOINTS WITH POWER

SAWS EQUIPPED WITH SHATTERPROOF ABRASIVE OR

DIAMOND-RIMMED BLADES. CUT 1/8-INCH- (3.2-MM-) WIDE

JOINTS INTO CONCRETE WHEN CUTTING ACTION WILL NOT

TEAR, ABRADE, OR OTHERWISE DAMAGE SURFACE AND

BEFORE CONCRETE DEVELOPS RANDOM CONTRACTION

CRACKS.

D. ISOLATION JOINTS IN SLABS-ON-GRADE: AFTER REMOVING

FORMWORK, INSTALL JOINT-FILLER STRIPS AT SLAB JUNCTIONS WITH

VERTICAL SURFACES, SUCH AS COLUMN PEDESTALS, FOUNDATION

WALLS, GRADE BEAMS, AND OTHER LOCATIONS, AS INDICATED.

3.04 CONCRETE PLACEMENT

A. BEFORE PLACING CONCRETE, VERIFY THAT INSTALLATION OF

FORMWORK, REINFORCEMENT, AND EMBEDDED ITEMS IS COMPLETE

AND THAT REQUIRED INSPECTIONS HAVE BEEN PERFORMED.

1. DEPOSIT CONCRETE CONTINUOUSLY IN ONE LAYER.

B. PLACE CONCRETE OVER COMPACTED SUB-GRADE, MINIMUM 95%

DENSITY PER ASTM D1557. SUBMIT TEST REPORT TO OWNER.

3.05 FINISHING FLOORS AND SLABS

A. GENERAL: COMPLY WITH ACI 302.1R RECOMMENDATIONS FOR

SCREEDING, RESTRAIGHTENING, AND FINISHING OPERATIONS FOR

CONCRETE SURFACES. DO NOT WET CONCRETE SURFACES.

B. FLOAT FINISH: CONSOLIDATE SURFACE WITH POWER-DRIVEN FLOATS

OR BY HAND FLOATING IF AREA IS SMALL OR INACCESSIBLE TO

POWER DRIVEN FLOATS. RESTRAIGHTEN, CUT DOWN HIGH SPOTS,

AND FILL LOW SPOTS. REPEAT FLOAT PASSES AND

RESTRAIGHTENING UNTIL SURFACE IS LEFT WITH A UNIFORM,

SMOOTH, GRANULAR TEXTURE.

C. TROWEL FINISH: AFTER APPLYING FLOAT FINISH, APPLY FIRST

TROWELING AND CONSOLIDATE CONCRETE BY HAND OR

POWER-DRIVEN TROWEL. CONTINUE TROWELING PASSES AND

RESTRAIGHTEN UNTIL SURFACE IS FREE OF TROWEL MARKS AND

UNIFORM IN TEXTURE AND APPEARANCE. GRIND SMOOTH ANY

SURFACE DEFECTS THAT WOULD TELEGRAPH THROUGH APPLIED

COATINGS OR FLOOR COVERINGS.

D. BROOM FINISH: APPLY A BROOM FINISH TO EXTERIOR CONCRETE

PLATFORMS, STEPS, AND RAMPS, AND ELSEWHERE AS INDICATED.

3.06 CONCRETE PROTECTING AND CURING

A. GENERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE

DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. COMPLY

WITH ACI 306.1 FOR COLD-WEATHER PROTECTION AND ACI 301 FOR

HOT-WEATHER PROTECTION DURING CURING.

END OF SECTION 033000

SECTION 042000 - UNIT MASONRY

PART 1 - GENERAL

1.1 SUMMARY

A. THIS SECTION INCLUDES UNIT MASONRY ASSEMBLIES CONSISTING OF

THE FOLLOWING,

1. CONCRETE MASONRY UNITS (CMUS).

2. DECORATIVE CONCRETE MASONRY UNITS.

3. PRE-FACED CONCRETE MASONRY UNITS.

4. CONCRETE BRICK.

5. FACE BRICK.

6. HOLLOW BRICK.

7. OTHER MATERIALS NECESSARY TO MATCH EXISTING BUILDING

CONSTRUCTION.

1.2 PROJECT CONDITIONS

A. COLD-WEATHER REQUIREMENTS: DO NOT USE FROZEN MATERIALS

OR MATERIALS MIXED OR COATED WITH ICE OR FROST. DO NOT BUILD

ON FROZEN SUBSTRATES. REMOVE AND REPLACE UNIT MASONRY

DAMAGED BY FROST OR BY FREEZING CONDITIONS. COMPLY WITH

COLD-WEATHER CONSTRUCTION REQUIREMENTS CONTAINED IN ACI

530.1/ASCE 6/TMS 602.

B. HOT-WEATHER REQUIREMENTS: COMPLY WITH HOT-WEATHER

CONSTRUCTION REQUIREMENTS CONTAINED IN ACI 530.1/ASCE 6/TMS

602.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. IN OTHER PART 2 ARTICLES WHERE TITLES BELOW INTRODUCE LISTS,

THE FOLLOWING REQUIREMENTS APPLY TO PRODUCT SELECTION:

1. PROVIDE PRODUCTS FROM MANUFACTURERS THAT MEET

REQUIREMENTS.

2.2 COLORS, TEXTURES, AND PATTERNS

A. AS SCHEDULED ON DRAWINGS.

2.3 CONCRETE MASONRY UNITS (CMUS)

A. SHAPES: PROVIDE SPECIAL SHAPES FOR LINTELS, CORNERS, JAMBS,

SASHES, MOVEMENT JOINTS, HEADERS, BONDING, AND OTHER

SPECIAL CONDITIONS.

B. CONCRETE MASONRY UNITS: ASTM C 90.

1. WEIGHT CLASSIFICATION: NORMAL WEIGHT.

2.4 BRICK

A. GENERAL: PROVIDE SHAPES INDICATED AND AS FOLLOWS:

1. FOR ENDS OF SILLS AND CAPS AND FOR SIMILAR

APPLICATIONS THAT WOULD OTHERWISE EXPOSE UNFINISHED

BRICK SURFACES, PROVIDE UNITS WITHOUT CORES OR FROGS

AND WITH EXPOSED SURFACES FINISHED. WHERE REQUIRED

TO MATCH EXISTING.

2. PROVIDE SPECIAL SHAPES FOR APPLICATIONS WHERE SHAPES

PRODUCED BY SAWING WOULD RESULT IN SAWED SURFACES

BEING EXPOSED TO VIEW.

B. FACE BRICK: ASTM C 216 UBC STANDARD 21-1, GRADE SW, TYPE FBX.

C. HOLLOW BRICK: ASTM C 652, GRADE SW.

2.6 REINFORCEMENT

A. UNCOATED STEEL REINFORCING BARS: ASTM A 615/A 615M OR ASTM

A 996/A 996M, GRADE 60 (GRADE 420).

B. MASONRY JOINT REINFORCEMENT: ASTM A 951, MILL GALVANIZED,

CARBON-STEEL WIRE FOR INTERIOR WALLS AND HOT-DIP

GALVANIZED, CARBON-STEEL WIRE FOR EXTERIOR WALLS.

1. WIRE SIZE FOR SIDE RODS: W1.7 OR 0.148-INCH (3.8-MM)

DIAMETER.

2. WIRE SIZE FOR CROSS RODS: W1.7 OR 0.148-INCH (3.8-MM)

DIAMETER.

3. WIRE SIZE FOR VENEER TIES: W2.8 OR 0.188-INCH (4.8-MM)

DIAMETER.

4. SPACING OF CROSS RODS, TABS, AND CROSS TIES: NOT MORE

THAN 16 INCHES (407 MM) O.C.

5. SINGLE-WYTHE MASONRY: EITHER LADDER OR TRUSS TYPE

WITH SINGLE PAIR OF SIDE RODS.

6. MULTIWYTHE MASONRY:

A. LADDER TYPE WITH 1 SIDE ROD AT EACH FACE SHELL OF HOLLOW

MASONRY UNITS MORE THAN 4 INCHES (100 MM) IN WIDTH, PLUS 1

SIDE ROD AT EACH WYTHE OF MASONRY 4 INCHES (100 MM) OR LESS

IN WIDTH.

2.7 TIES AND ANCHORS

A. MATERIALS:

1. HOT-DIP GALVANIZED, CARBON-STEEL WIRE: ASTM A 82, WITH

ASTM A 153/A 153M, CLASS B-2 COATING.

2. STEEL SHEET, GALVANIZED AFTER FABRICATION: ASTM A

1008/A 1008M, COMMERCIAL STEEL, HOT-DIP GALVANIZED

AFTER FABRICATION TO COMPLY WITH ASTM A 153/A 153M.

3. STEEL PLATES, SHAPES, AND BARS: ASTM A 36/A 36M.

B. WIRE TIES, GENERAL: UNLESS OTHERWISE INDICATED, SIZE WIRE

TIES TO EXTEND AT LEAST HALFWAY THROUGH VENEER BUT WITH AT

LEAST 5/8-INCH (16-MM) COVER ON OUTSIDE FACE. OUTER ENDS OF

WIRES ARE BENT 90 DEGREES AND EXTEND 2 INCHES (50 MM)

PARALLEL TO FACE OF VENEER.

C. INDIVIDUAL WIRE TIES: RECTANGULAR UNITS WITH CLOSED ENDS

AND NOT LESS THAN 4 INCHES (100 MM) WIDE.

1. WIRE: FABRICATE FROM 3/16-INCH- (4.8-MM-) DIAMETER,

HOT-DIP GALVANIZED STEEL WIRE.

2.8 EMBEDDED FLASHING MATERIALS

A. METAL FLASHING: COMPLY WITH SMACNA'S ARCHITECTURAL SHEET

METAL MANUAL.

B. FLEXIBLE FLASHING: FOR FLASHING NOT EXPOSED TO THE EXTERIOR:

1. COPPER-LAMINATED FLASHING: 7-OZ./SQ. FT. (2-KG/SQ. M)

COPPER SHEET BONDED WITH ASPHALT BETWEEN 2 LAYERS

OF GLASS-FIBER CLOTH.

C. SOLDER AND SEALANTS FOR SHEET METAL FLASHINGS: AS

SPECIFIED BY FLASHING MANUFACTURER.

D. ADHESIVES, PRIMERS, AND SEAM TAPES FOR FLASHINGS: AS

RECOMMENDED BY FLASHING MANUFACTURER.

2.9 MISCELLANEOUS MASONRY ACCESSORIES

A. COMPRESSIBLE FILLER: PREMOLDED FILLER STRIPS COMPLYING

WITH ASTM D 1056, GRADE 2A1, COMPRESSIBLE UP TO 35 PERCENT,

FORMULATED FROM NEOPRENE URETHANE OR PVC.

B. PREFORMED CONTROL-JOINT GASKETS: MADE FROM

STYRENE-BUTADIENE-RUBBER COMPOUND, COMPLYING WITH ASTM D

2000, DESIGNATION M2AA-805 AND DESIGNED TO FIT STANDARD SASH

BLOCK AND TO MAINTAIN LATERAL STABILITY IN MASONRY WALL.

C. BOND-BREAKER STRIPS: ASPHALT-SATURATED, ORGANIC ROOFING

FELT COMPLYING WITH ASTM D 226, TYPE I (NO. 15 ASPHALT FELT).

D. WEEP/VENT PRODUCTS: USE ONE OF THE FOLLOWING, UNLESS

OTHERWISE INDICATED:

1. RECTANGULAR PLASTIC WEEP/VENT TUBING: CLEAR

BUTYRATE, 3/8 BY 1-1/2 BY 3-1/2 INCHES (9 BY 38 BY 89 MM)

LONG.

2.10 MASONRY CLEANERS

A. PROPRIETARY ACIDIC CLEANER: MANUFACTURER'S

STANDARD-STRENGTH CLEANER DESIGNED FOR REMOVING

MORTAR/GROUT STAINS FROM NEW MASONRY WITHOUT DAMAGING

MASONRY. USE PRODUCT APPROVED FOR INTENDED USE BY

CLEANER MANUFACTURER AND MANUFACTURER OF MASONRY UNITS

BEING CLEANED.

2.11 MORTAR AND GROUT MIXES

A. GENERAL: DO NOT USE ADMIXTURES, UNLESS OTHERWISE

INDICATED.

1. DO NOT USE CALCIUM CHLORIDE IN MORTAR OR GROUT.

2. LIMIT CEMENTITIOUS MATERIALS IN MORTAR FOR EXTERIOR

AND REINFORCED MASONRY TO PORTLAND CEMENT AND LIME.

3. ADD COLD-WEATHER ADMIXTURE (IF USED) AT SAME RATE FOR

ALL MORTAR THAT WILL BE EXPOSED TO VIEW, REGARDLESS

OF WEATHER CONDITIONS, TO ENSURE THAT MORTAR COLOR

IS CONSISTENT.

B. MORTAR FOR UNIT MASONRY: COMPLY WITH ASTM C 270,

PROPORTION SPECIFICATION.

PART 3 - EXECUTION

3.1 INSTALLATION, GENERAL

A. USE FULL-SIZE UNITS WITHOUT CUTTING IF POSSIBLE. IF CUTTING IS

REQUIRED, CUT UNITS WITH MOTOR-DRIVEN SAWS, PROVIDE CLEAN,

SHARP, UN-CHIPPED EDGES. ALLOW UNITS TO DRY BEFORE LAYING

UNLESS WETTING OF UNITS IS SPECIFIED. INSTALL CUT UNITS WITH

CUT SURFACES AND, WHERE POSSIBLE, CUT EDGES CONCEALED.

B. SELECT AND ARRANGE UNITS FOR EXPOSED UNIT MASONRY TO

PRODUCE A UNIFORM BLEND OF COLORS AND TEXTURES.

C. WETTING OF BRICK: WET BRICK BEFORE LAYING IF INITIAL RATE OF

ABSORPTION EXCEEDS 30 G/30 SQ. IN. (30 G/194 SQ. CM) PER MINUTE

WHEN TESTED PER ASTM C 67. ALLOW UNITS TO ABSORB WATER SO

THEY ARE DAMP BUT NOT WET AT TIME OF LAYING.

D. COMPLY WITH TOLERANCES IN ACI 530.1/ASCE 6/TMS 602 AND WITH

THE FOLLOWING:

1. FOR CONSPICUOUS VERTICAL LINES, SUCH AS EXTERNAL

CORNERS, DOOR JAMBS, REVEALS, AND EXPANSION AND

CONTROL JOINTS, DO NOT VARY FROM PLUMB BY MORE THAN

1/8 INCH IN 10 FEET (3 MM IN 3 M), 1/4 INCH IN 20 FEET (6 MM IN

6 M), OR 1/2 INCH (12 MM) MAXIMUM.

2. FOR CONSPICUOUS HORIZONTAL LINES, SUCH AS LINTELS,

SILLS, PARAPETS, AND REVEALS, DO NOT VARY FROM LEVEL

BY MORE THAN 1/8 INCH IN 10 FEET (3 MM IN 3 M), 1/4 INCH IN 20

FEET (6 MM IN 6 M), OR 1/2 INCH (12 MM) MAXIMUM.

3.2 LAYING MASONRY WALLS

A. LAY OUT WALLS IN ADVANCE FOR ACCURATE SPACING OF SURFACE

BOND PATTERNS WITH UNIFORM JOINT THICKNESSES AND FOR

ACCURATE LOCATION OF OPENINGS, MOVEMENT-TYPE JOINTS,

RETURNS, AND OFFSETS. AVOID USING LESS-THAN-HALF-SIZE UNITS,

PARTICULARLY AT CORNERS, JAMBS, AND, WHERE POSSIBLE, AT

OTHER LOCATIONS.

B. BOND PATTERN FOR EXPOSED MASONRY: UNLESS OTHERWISE

INDICATED, LAY EXPOSED MASONRY IN RUNNING BOND, DO NOT USE

UNITS WITH LESS THAN NOMINAL 4-INCH (100-MM) HORIZONTAL FACE

DIMENSIONS AT CORNERS OR JAMBS.

C. BUILT-IN WORK: AS CONSTRUCTION PROGRESSES, BUILD IN ITEMS

SPECIFIED IN THIS AND OTHER SECTIONS. FILL IN SOLIDLY WITH

MASONRY AROUND BUILT-IN ITEMS.

D. FILL SPACE BETWEEN STEEL FRAMES AND MASONRY SOLIDLY WITH

MORTAR, UNLESS OTHERWISE INDICATED.

E. FILL CORES IN HOLLOW CONCRETE MASONRY UNITS WITH GROUT 24

INCHES (600 MM) UNDER BEARING PLATES, BEAMS, LINTELS, POSTS,

AND SIMILAR ITEMS, UNLESS OTHERWISE INDICATED.

3.3 MORTAR BEDDING AND JOINTING

A. LAY HOLLOW BRICK AND CONCRETE MASONRY UNITS AS FOLLOWS:

1. WITH FACE SHELLS FULLY BEDDED IN MORTAR AND WITH HEAD

JOINTS OF DEPTH EQUAL TO BED JOINTS.

2. WITH WEBS FULLY BEDDED IN MORTAR IN ALL COURSES OF

PIERS, COLUMNS, AND PILASTERS.

3. WITH WEBS FULLY BEDDED IN MORTAR IN GROUTED MASONRY,

INCLUDING STARTING COURSE ON FOOTINGS.

4. WITH ENTIRE UNITS, INCLUDING AREAS UNDER CELLS, FULLY

BEDDED IN MORTAR AT STARTING COURSE ON FOOTINGS

WHERE CELLS ARE NOT GROUTED.

B. LAY SOLID MASONRY UNITS WITH COMPLETELY FILLED BED AND HEAD

JOINTS, BUTTER ENDS WITH SUFFICIENT MORTAR TO FILL HEAD

JOINTS AND SHOVE INTO PLACE. DO NOT DEEPLY FURROW BED

JOINTS OR SLUSH HEAD JOINTS.

C. TOOL EXPOSED JOINTS SLIGHTLY CONCAVE WHEN THUMBPRINT

HARD, USING A JOINTER LARGER THAN JOINT THICKNESS, UNLESS

OTHERWISE INDICATED.

D. CUT JOINTS FLUSH FOR MASONRY WALLS TO RECEIVE PLASTER OR

OTHER DIRECT-APPLIED FINISHES (OTHER THAN PAINT), UNLESS

OTHERWISE INDICATED.

3.04 COMPOSITE MASONRY

A. BOND WYTHES OF COMPOSITE MASONRY TOGETHER USING ONE OF

THE FOLLOWING METHODS:

1. INDIVIDUAL METAL TIES: PROVIDE TIES AS SHOWN INSTALLED

IN HORIZONTAL JOINTS, BUT NOT LESS THAN ONE METAL TIE

FOR 2.67 SQ. FT. (0.25 SQ. M) OF WALL AREA SPACED NOT TO

EXCEED 24 INCHES (610 MM) O.C. HORIZONTALLY AND 16

INCHES (406 MM) O.C. VERTICALLY. STAGGER TIES IN

ALTERNATE COURSES. PROVIDE ADDITIONAL TIES WITHIN 12

INCHES (305 MM) OF OPENINGS AND SPACE NOT MORE THAN

36 INCHES (915 MM) APART AROUND PERIMETER OF OPENINGS.

AT INTERSECTING AND ABUTTING WALLS, PROVIDE TIES AT NO

MORE THAN 24 INCHES (610 MM) O.C. VERTICALLY.

2. MASONRY JOINT REINFORCEMENT: INSTALLED IN HORIZONTAL

MORTAR JOINTS.

B. WHERE BED JOINTS OF BOTH WYTHES ALIGN, USE LADDER-TYPE

REINFORCEMENT EXTENDING ACROSS BOTH WYTHES.

C. WHERE BED JOINTS OF WYTHES DO NOT ALIGN, USE ADJUSTABLE

(TWO-PIECE) TYPE REINFORCEMENT WITH CONTINUOUS HORIZONTAL

WIRE IN FACING WYTHE ATTACHED TO TIES.

D. COLLAR JOINTS: SOLIDLY FILL COLLAR JOINTS BY PARGING FACE OF

FIRST WYTHE THAT IS LAID AND SHOVING UNITS OF OTHER WYTHE

INTO PLACE.

E. CORNERS: PROVIDE INTERLOCKING MASONRY UNIT BOND IN EACH

WYTHE AND COURSE AT CORNERS, UNLESS OTHERWISE INDICATED.

3.05 MASONRY JOINT REINFORCEMENT

A. GENERAL: INSTALL IN MORTAR WITH A MINIMUM COVER OF 5/8 INCH

(16 MM) ON EXTERIOR SIDE OF WALLS, 1/2 INCH (13 MM) ELSEWHERE.

LAP REINFORCEMENT A MINIMUM OF 6 INCHES (150 MM).

B. INTERRUPT JOINT REINFORCEMENT AT CONTROL AND EXPANSION

JOINTS, UNLESS OTHERWISE INDICATED.

C. PROVIDE CONTINUITY AT WALL INTERSECTIONS BY USING

PREFABRICATED T-SHAPED UNITS.

D. PROVIDE CONTINUITY AT CORNERS BY USING PREFABRICATED

L-SHAPED UNITS.

3.06 ANCHORING MASONRY VENEERS

A. ANCHOR MASONRY VENEERS TO WALL FRAMING OR CONCRETE AND

MASONRY BACKUP WITH MASONRY-VENEER ANCHORS TO COMPLY

WITH THE FOLLOWING REQUIREMENTS:

1. FASTEN SCREW-ATTACHED ANCHORS THROUGH SHEATHING

TO WALL FRAMING AND TO CONCRETE AND MASONRY BACKUP

WITH METAL FASTENERS OF TYPE INDICATED. .

2. EMBED TIE SECTIONS IN MASONRY JOINTS.

3. LOCATE ANCHOR SECTIONS TO ALLOW MAXIMUM VERTICAL

DIFFERENTIAL MOVEMENT OF TIES UP AND DOWN.

4. SPACE ANCHORS AS INDICATED, BUT NOT MORE THAN 16

INCHES (406 MM) O.C. VERTICALLY AND 24 INCHES (610 MM)

O.C. HORIZONTALLY WITH NOT LESS THAN 1 ANCHOR FOR

EACH 2.67 SQ. FT. (0.25 SQ. M) OF WALL AREA. INSTALL

ADDITIONAL ANCHORS WITHIN 12 INCHES (305 MM) OF

OPENINGS AND AT INTERVALS, NOT EXCEEDING 36 INCHES (914

MM), AROUND PERIMETER.

3.07 FLASHING, WEEP HOLES, CAVITY DRAINAGE, AND VENTS

A. GENERAL: INSTALL EMBEDDED FLASHING AND WEEP HOLES IN

MASONRY AT SHELF ANGLES, LINTELS, LEDGES, OTHER

OBSTRUCTIONS TO DOWNWARD FLOW OF WATER IN WALL, AND

WHERE INDICATED.

B. INSTALL FLASHING AS FOLLOWS, UNLESS OTHERWISE INDICATED:

1. PREPARE MASONRY SURFACES SO THEY ARE SMOOTH AND

FREE FROM PROJECTIONS THAT COULD PUNCTURE FLASHING.

WHERE FLASHING IS WITHIN MORTAR JOINT, PLACE

THROUGH-WALL FLASHING ON SLOPING BED OF MORTAR AND

COVER WITH MORTAR. BEFORE COVERING WITH MORTAR,

SEAL PENETRATIONS IN FLASHING AS RECOMMENDED BY

FLASHING MANUFACTURER.

2. AT LINTELS AND SHELF ANGLES, EXTEND FLASHING A MINIMUM

OF 6 INCHES (150 MM) INTO MASONRY AT EACH END. AT HEADS

AND SILLS, EXTEND FLASHING 6 INCHES (150 MM) AT ENDS AND

TURN UP NOT LESS THAN 2 INCHES (50 MM) TO FORM END

DAMS.

C. INSTALL WEEP HOLES IN HEAD JOINTS IN EXTERIOR WYTHES OF FIRST

COURSE OF MASONRY IMMEDIATELY ABOVE EMBEDDED FLASHING

AND AS FOLLOWS:

1. USE SPECIFIED WEEP/VENT PRODUCTS TO FORM WEEP HOLES.

2. SPACE WEEP HOLES 24 INCHES (600 MM) O.C., UNLESS

OTHERWISE INDICATED.

3. COVER CAVITY SIDE OF WEEP HOLES WITH PLASTIC INSECT

SCREENING AT CAVITIES INSULATED WITH LOOSE-FILL

INSULATION.

D. PLACE CAVITY DRAINAGE MATERIAL IN CAVITIES TO COMPLY WITH

CONFIGURATION REQUIREMENTS FOR CAVITY DRAINAGE MATERIAL IN

PART 2 "MISCELLANEOUS MASONRY ACCESSORIES" ARTICLE.

3.08 REINFORCED UNIT MASONRY INSTALLATION

A. TEMPORARY FORMWORK AND SHORES: CONSTRUCT FORMWORK

AND SHORES AS NEEDED TO SUPPORT REINFORCED MASONRY

ELEMENTS DURING CONSTRUCTION.

1. CONSTRUCT FORMWORK TO PROVIDE SHAPE, LINE, AND

DIMENSIONS OF COMPLETED MASONRY AS INDICATED. MAKE

FORMS SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF

MORTAR AND GROUT. BRACE, TIE, AND SUPPORT FORMS TO

MAINTAIN POSITION AND SHAPE DURING CONSTRUCTION AND

CURING OF REINFORCED MASONRY.

2. DO NOT REMOVE FORMS AND SHORES UNTIL REINFORCED

MASONRY MEMBERS HAVE HARDENED SUFFICIENTLY TO

CARRY THEIR OWN WEIGHT AND OTHER TEMPORARY LOADS

THAT MAY BE PLACED ON THEM DURING CONSTRUCTION.

B. PLACING REINFORCEMENT: COMPLY WITH REQUIREMENTS IN ACI

530.1/ASCE 6/TMS 602.

C. GROUTING: DO NOT PLACE GROUT UNTIL ENTIRE HEIGHT OF

MASONRY TO BE GROUTED HAS ATTAINED ENOUGH STRENGTH TO

RESIST GROUT PRESSURE.

1. COMPLY WITH REQUIREMENTS IN ACI 530.1/ASCE 6/TMS 602

FOR CLEANOUTS AND FOR GROUT PLACEMENT, INCLUDING

MINIMUM GROUT SPACE AND MAXIMUM POUR HEIGHT.

2. LIMIT HEIGHT OF VERTICAL GROUT POURS TO NOT MORE THAN

60 INCHES (1520 MM).

3.09 PARGING

A. PARGE EXTERIOR FACES OF BELOW-GRADE MASONRY WALLS,

WHERE INDICATED, IN 2 UNIFORM COATS TO A TOTAL THICKNESS OF

3/4 INCH (19 MM) WITH A STEEL-TROWEL FINISH. FORM A WASH AT

TOP OF PARGING AND A COVE AT BOTTOM. DAMP-CURE PARGING

FOR AT LEAST 24 HOURS AND PROTECT PARGING UNTIL CURED.

3.10 CLEANING

A. IN-PROGRESS CLEANING: CLEAN UNIT MASONRY AS WORK

PROGRESSES BY DRY BRUSHING TO REMOVE MORTAR FINS AND

SMEARS BEFORE TOOLING JOINTS.

B. FINAL CLEANING: AFTER MORTAR IS THOROUGHLY SET AND CURED,

CLEAN EXPOSED MASONRY AS FOLLOWS:

1. TEST CLEANING METHODS ON SAMPLE WALL PANEL, LEAVE

ONE-HALF OF PANEL UNCLEANED FOR COMPARISON

PURPOSES.

2. PROTECT ADJACENT SURFACES FROM CONTACT WITH

CLEANER.

3. WET WALL SURFACES WITH WATER BEFORE APPLYING

CLEANERS, REMOVE CLEANERS PROMPTLY BY RINSING

SURFACES THOROUGHLY WITH CLEAR WATER.

4. CLEAN BRICK BY BUCKET-AND-BRUSH HAND-CLEANING

METHOD DESCRIBED IN BIA TECHNICAL NOTES 20.

5. CLEAN MASONRY WITH A PROPRIETARY ACIDIC CLEANER

APPLIED ACCORDING TO MANUFACTURER'S WRITTEN

INSTRUCTIONS.

6. CLEAN CONCRETE MASONRY BY CLEANING METHOD

INDICATED IN NCMA TEK 8-2A APPLICABLE TO TYPE OF STAIN

ON EXPOSED SURFACES.

3.11 MASONRY WASTE DISPOSAL

A. WASTE DISPOSAL AS FILL MATERIAL: DISPOSE OF CLEAN MASONRY

WASTE, INCLUDING EXCESS OR SOIL-CONTAMINATED SAND, WASTE

MORTAR, AND BROKEN MASONRY UNITS, BY CRUSHING AND MIXING

WITH FILL MATERIAL AS FILL IS PLACED.

1. DO NOT DISPOSE OF MASONRY WASTE AS FILL WITHIN 18

INCHES (450 MM) OF FINISHED GRADE.

2. REMOVE EXCESS CLEAN MASONRY WASTE THAT CANNOT BE

USED AS FILL, AS DESCRIBED ABOVE, AND OTHER MASONRY

WASTE, AND LEGALLY DISPOSE OF OFF OWNER'S PROPERTY.

END OF SECTION 042000

SECTION 055000 - METAL FABRICATIONS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. SHOP FABRICATED STEEL ITEMS.

1.02 REFERENCES

A. ASTM A 36/A 36M - STANDARD SPECIFICATION FOR CARBON

STRUCTURAL STEEL, 2001.

B. ASTM A 53/A 53M - STANDARD SPECIFICATION FOR PIPE, STEEL, BLACK

AND HOT-DIPPED, ZINC-COATED, WELDED AND SEAMLESS, 2002.

C. ASTM A 123/A 123M - STANDARD SPECIFICATION FOR ZINC (HOT-DIP

GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS, 2002.

D. ASTM A 153/A 153M - STANDARD SPECIFICATION FOR ZINC COATING

(HOT-DIP) ON IRON AND STEEL HARDWARE, 2002.

E. ASTM A 283/A 283M - STANDARD SPECIFICATION FOR LOW AND

INTERMEDIATE TENSILE STRENGTH CARBON STEEL PLATES, 2000.

F. ASTM A 325 - STANDARD SPECIFICATION FOR STRUCTURAL BOLTS,

STEEL, HEAT TREATED, 120/105 KSI MINIMUM TENSILE STRENGTH,

2002.

G. ASTM A 325M - STANDARD SPECIFICATION FOR HIGH-STRENGTH

BOLTS FOR STRUCTURAL STEEL JOINTS (METRIC), 2000.

H. ASTM A 501 - STANDARD SPECIFICATION FOR HOT-FORMED WELDED

AND SEAMLESS CARBON STEEL STRUCTURAL TUBING, 2001.

I. AWS D1.1 - STRUCTURAL WELDING CODE - STEEL, AMERICAN WELDING

SOCIETY, 2002.

J. SSPC-PAINT 20 - ZINC-RICH PRIMERS (TYPE I, "INORGANIC," AND TYPE

II, "ORGANIC"), SOCIETY FOR PROTECTIVE COATINGS, 2002.

K. SSPC-SP 2 - HAND TOOL CLEANING, SOCIETY FOR PROTECTIVE

COATINGS, 1982 (ED. 2000).

PART 2 PRODUCTS

2.01 MATERIALS - STEEL

A. STEEL SECTIONS: ASTM A 36/A 36M.

B. STEEL TUBING: ASTM A 501 HOT-FORMED STRUCTURAL TUBING.

C. PLATES: ASTM A 283.

D. PIPE: ASTM A 53/A 53M, GRADE B SCHEDULE 40, BLACK FINISH.

E. BOLTS, NUTS, AND WASHERS: ASTM A 325 (ASTM A 325M), TYPE 1,

GALVANIZED TO ASTM A 153/A 153M WHERE CONNECTING

GALVANIZED COMPONENTS.

F. WELDING MATERIALS: AWS D1.1, TYPE REQUIRED FOR MATERIALS

BEING WELDED.

G. TOUCH-UP PRIMER FOR GALVANIZED SURFACES: SSPC-PAINT 20,

TYPE I - INORGANIC, COMPLYING WITH VOC LIMITATIONS OF

AUTHORITIES HAVING JURISDICTION.

2.02 FABRICATION

A. FIT AND SHOP ASSEMBLE ITEMS IN LARGEST PRACTICAL SECTIONS,

FOR DELIVERY TO SITE.

B. FABRICATE ITEMS WITH JOINTS TIGHTLY FITTED AND SECURED.

C. CONTINUOUSLY SEAL JOINED MEMBERS BY CONTINUOUS WELDS OR

INTERMITENT WELDS AS INDICATED.

D. GRIND EXPOSED JOINTS FLUSH AND SMOOTH WITH ADJACENT FINISH

SURFACE. MAKE EXPOSED JOINTS BUTT TIGHT, FLUSH, AND HAIRLINE.

EASE EXPOSED EDGES TO SMALL UNIFORM RADIUS.

E. EXPOSED MECHANICAL FASTENINGS: FLUSH COUNTERSUNK SCREWS

OR BOLTS, UNOBTRUSIVELY LOCATED, CONSISTENT WITH DESIGN OF

COMPONENT, EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE.

F. SUPPLY COMPONENTS REQUIRED FOR ANCHORAGE OF

FABRICATIONS. FABRICATE ANCHORS AND RELATED COMPONENTS

OF SAME MATERIAL AND FINISH AS FABRICATION, EXCEPT WHERE

SPECIFICALLY NOTED OTHERWISE.

2.03 FABRICATED ITEMS

A. LEDGE ANGLES, SHELF ANGLES, CHANNELS, AND PLATES NOT

ATTACHED TO STRUCTURAL FRAMING: FOR SUPPORT AND

ATTACHMENT OF INTERIOR SOFFIT AND MISC. CONSTRUCTION

INDICATED ON DRAWINGS, PRIME PAINT FINISH.

B. LINTELS: AS DETAILED, GALVANIZED FINISH.

2.04 FINISHES - STEEL

A. PRIME PAINT ALL STEEL ITEMS.

B. PREPARE SURFACES TO BE PRIMED IN ACCORDANCE WITH SSPC-SP2.

C. CLEAN SURFACES OF RUST, SCALE, GREASE, AND FOREIGN MATTER

PRIOR TO FINISHING.

D. PRIME PAINTING: TWO COATS.

E. GALVANIZING OF STRUCTURAL STEEL MEMBERS: GALVANIZE AFTER

FABRICATION TO ASTM A 123/A 123M REQUIREMENTS. PROVIDE

MINIMUM 1.7 OZ/SQ FT (530 G/SQ M) GALVANIZED COATING.

F. GALVANIZING OF NON-STRUCTURAL ITEMS: GALVANIZE AFTER

FABRICATION TO ASTM A 123/A 123M REQUIREMENTS.

2.05 FABRICATION TOLERANCES

A. SQUARENESS: 1/8 INCH (3 MM) MAXIMUM DIFFERENCE IN DIAGONAL

MEASUREMENTS.

B. MAXIMUM OFFSET BETWEEN FACES: 1/16 INCH (1.5 MM).

C. MAXIMUM MISALIGNMENT OF ADJACENT MEMBERS: 1/16 INCH (1.5

MM).

D. MAXIMUM BOW: 1/8 INCH (3 MM) IN 48 INCHES (1.2 M).

E. MAXIMUM DEVIATION FROM PLANE: 1/16 INCH (1.5 MM) IN 48 INCHES

(1.2 M).

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT FIELD CONDITIONS ARE ACCEPTABLE AND ARE READY

TO RECEIVE WORK.

3.02 PREPARATION

A. CLEAN AND STRIP PRIMED STEEL ITEMS TO BARE METAL WHERE SITE

WELDING IS REQUIRED.

B. SUPPLY SETTING TEMPLATES TO THE APPROPRIATE ENTITIES FOR

STEEL ITEMS REQUIRED TO BE CAST INTO CONCRETE OR EMBEDDED

IN MASONRY.

3.03 INSTALLATION

A. INSTALL ITEMS PLUMB AND LEVEL, ACCURATELY FITTED, FREE FROM

DISTORTION OR DEFECTS.

B. PROVIDE FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY

BRACING TO MAINTAIN TRUE ALIGNMENT UNTIL COMPLETION OF

ERECTION AND INSTALLATION OF PERMANENT ATTACHMENTS.

C. PERFORM FIELD WELDING IN ACCORDANCE WITH AWS D1.1.

D. OBTAIN APPROVAL PRIOR TO SITE CUTTING OR MAKING

ADJUSTMENTS NOT SCHEDULED.

E. AFTER ERECTION, PRIME WELDS, ABRASIONS, AND SURFACES NOT

SHOP PRIMED OR GALVANIZED, EXCEPT SURFACES TO BE IN

CONTACT WITH CONCRETE.

3.04 ERECTION TOLERANCES

A. MAXIMUM VARIATION FROM PLUMB: 1/4 INCH (6 MM) PER STORY,

NON-CUMULATIVE.

B. MAXIMUM OFFSET FROM TRUE ALIGNMENT: 1/4 INCH (6 MM).

C. MAXIMUM OUT-OF-POSITION: 1/4 INCH (6 MM).

END OF SECTION 055000

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.2

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.2

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 9: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 061000 - ROUGH CARPENTRY

1.01 SECTION INCLUDES

A. TELEPHONE AND ELECTRICAL PANEL BOARDS.

B. WOOD NAILERS AND CURBS FOR ROOFING AND ITEMS INSTALLED ON

ROOF.

C. CONCEALED WOOD BLOCKING FOR SUPPORT OF EQUIPMENT, SOFFIT

PANELS, AND SIGNAGE.

D. MISCELLANEOUS WOOD NAILERS AND FURRING STRIPS.

1.02 REFERENCES

A. AFPA T10 - WOOD FRAME CONSTRUCTION MANUAL, AMERICAN

FOREST AND PAPER ASSOCIATION, 2001.

B. AWPA C2 - LUMBER, TIMBER, BRIDGE TIES AND MINE TIES --

PRESERVATIVE TREATMENT BY PRESSURE PROCESSES, AMERICAN

WOOD-PRESERVERS' ASSOCIATION, 2001.

C. PS 1 - CONSTRUCTION AND INDUSTRIAL PLYWOOD, NATIONAL

INSTITUTE OF STANDARDS AND TECHNOLOGY (DEPARTMENT OF

COMMERCE), 1995. D. PS 20 - AMERICAN SOFTWOOD LUMBER

STANDARD, NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

(DEPARTMENT OF COMMERCE), 1999. E. WWPA G-5 - WESTERN

LUMBER GRADING RULES, WESTERN WOOD PRODUCTS ASSOCIATION,

1998.

1.03 QUALITY ASSURANCE

A. LUMBER: COMPLY WITH PS 20 AND APPROVED GRADING RULES AND

INSPECTION AGENCIES.

1.04 DELIVERY, STORAGE, AND HANDLING

A. COVER WOOD PRODUCTS TO PROTECT AGAINST MOISTURE.

SUPPORT STACKED PRODUCTS TO PREVENT DEFORMATION AND TO

ALLOW AIR CIRCULATION.

PART 2 - PRODUCTS

2.01 DIMENSION LUMBER FOR CONCEALED APPLICATIONS - ALL SHALL BE FIRE

RETARDANT TREATED

A. GRADING AGENCY: WESTERN WOOD PRODUCTS ASSOCIATION

(WWPA).

B. SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S.

C. MOISTURE CONTENT: S-DRY OR MC19.

D. MISCELLANEOUS BLOCKING, FURRING, AND NAILERS:

1. LUMBER: S4S, NO. 2 OR STANDARD GRADE.

2.02 CONSTRUCTION PANELS - ALL SHALL BE FIRE RETARDANT TREATED

A. MISCELLANEOUS PANELS:

1. CONCEALED PLYWOOD: PS 1, C-C PLUGGED, EXTERIOR

GRADE.

2. EXPOSED PLYWOOD: PS 1, A-D, INTERIOR GRADE.

3. ELECTRICAL COMPONENT MOUNTING: APA RATED SHEATHING,

FIRE RETARDANT TREATED.

2.03 ACCESSORIES

A. FASTENERS AND ANCHORS:

1. FASTENERS: ZINC ELECTROPLATED STEEL FOR HIGH

HUMIDITY AND TREATED WOOD LOCATIONS, UNFINISHED

STEEL ELSEWHERE.

2. DRYWALL SCREWS: BUGLE HEAD, HARDENED STEEL, POWER

DRIVEN TYPE, LENGTH THREE TIMES THICKNESS OF

SHEATHING.

3. ANCHORS: TOGGLE BOLT TYPE FOR ANCHORAGE TO HOLLOW

MASONRY, EXPANSION SHIELD AND LAG BOLT AT SOLID

MASONRY, BOLT ADN BALLISTIC ANCHORAGES TO STEEL.

2.04 FACTORY WOOD TREATMENT

A. TREATED LUMBER AND PLYWOOD: COMPLY WITH REQUIREMENTS OF

AWPA U1-05 - USE CATEGORY SYSTEM FOR WOOD TREATMENTS

DETERMINED BY USE CATEGORIES, EXPECTED SERVICE CONDITIONS,

AND SPECIFIC APPLICATIONS.

B. FIRE-RETARDANT-TREATED MATERIALS

1. GENERAL: COMPLY WITH PERFORMANCE REQUIREMENTS IN

AWPA C20 (LUMBER) AND AWPA C27 (PLYWOOD). FLAME

SPREAD SHALL BE 25 OR LESS PER ASTM E84

A. USE EXTERIOR TYPE FOR EXTERIOR LOCATIONS AND

WHERE INDICATED.

B. USE INTERIOR TYPE A, HIGH TEMPERATURE (HT) FOR

ENCLOSED ROOF FRAMING, FRAMING IN ATTIC SPACES,

AND WHERE INDICATED.

C. USE INTERIOR TYPE A, UNLESS OTHERWISE INDICATED.

2. IDENTIFY FIRE-RETARDANT-TREATED WOOD WITH

APPROPRIATE CLASSIFICATION MARKING OF TESTING AND

INSPECTING AGENCY; AND WITH INFORMATION ACCEPTABLE

TO AUTHORITIES HAVING JURISDICTION.

C. PLYWOOD BACKING PANELS

1. TELEPHONE, ELECTRICAL, EQUIPMENT BACKING PANELS: DOC

PS 1, EXPOSURE 1, C-D PLUGGED, FIRE-RETARDANT TREATED,

IN THICKNESS INDICATED OR, IF NOT INDICATED, NOT LESS

THAN 5/8-INCH (13-MM) NOMINAL THICKNESS.

2. WATER DELIVERY SYSTEM, FIRE-RETARDENT TREATED IN

THICKNESS INDICATED OR, IF NOT INDICATED, NOT LESS THAN

5/8-INCH (13-MM) NOMINAL THICKNESS.

D. PRESSURE TREATMENT OF LUMBER ABOVE GRADE: AWPA

TREATMENT C2 USING WATERBORNE PRESERVATIVE TO 0.25 LB/CU FT

(4.0 KG/CU M) RETENTION.

1. KILN DRY AFTER TREATMENT TO MAXIMUM MOISTURE

CONTENT OF 19 PERCENT.

2. TREAT WOOD IN CONTACT WITH ROOFING, FLASHING, OR

WATERPROOFING.

3. TREAT WOOD IN CONTACT WITH MASONRY OR CONCRETE.

4. TREAT WOOD LESS THAN 18 INCHES (450 MM) ABOVE GRADE.

PART 3 - EXECUTION

3.01 FURRING INSTALLATION

A. SET FURRING, NAILERS AND BLOCKING MEMBERS LEVEL, PLUMB, AND

TRUE TO LINE. DISCARD PIECES WITH DEFECTS THAT WOULD LOWER

REQUIRED STRENGTH.

B. MAKE PROVISIONS FOR TEMPORARY CONSTRUCTION LOADS, AND

PROVIDE TEMPORARY BRACING SUFFICIENT TO MAINTAIN

STRUCTURE IN TRUE ALIGNMENT AND SAFE CONDITION UNTIL

COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT

BRACING.

C. INSTALL MEMBERS FULL LENGTH WITHOUT SPLICES UNLESS

OTHERWISE SPECIFICALLY DETAILED.

D. COMPLY WITH MEMBER SIZES, SPACING, AND CONFIGURATIONS

INDICATED, AND FASTENER SIZE AND SPACING INDICATED, BUT NOT

LESS THAN REQUIRED BY AFPA WOOD FRAME CONSTRUCTION

MANUAL. E. PROVIDE MISCELLANEOUS MEMBERS AS INDICATED OR

AS REQUIRED TO SUPPORT FINISHES, FIXTURES, SPECIALTY ITEMS,

AND TRIM.

3.02 SITE APPLIED WOOD TREATMENT

A. APPLY PRESERVATIVE TREATMENT COMPATIBLE WITH FACTORY

APPLIED TREATMENT AT SITE-SAWN CUTS, COMPLYING WITH

MANUFACTURER'S INSTRUCTIONS.

B. ALLOW PRESERVATIVE TO DRY PRIOR TO ERECTING MEMBERS.

END OF SECTION

SECTION 062000 - FINISH CARPENTRY

PART 1 GENERAL

1.01 SECTION INCLUDES

A. INSTALLATION OF MILLWORK.

B. INSTALLATION OF OWNER RETAIL SHELVING (COORDINATE WITH PET

SUPPLIES PLUS)..

C. FINISH CARPENTRY ITEMS.

D. HARDWARE AND ATTACHMENT ACCESSORIES.

1.02 REFERENCES

A. AWI (QSI) - ARCHITECTURAL WOODWORK QUALITY STANDARDS

ILLUSTRATED, ARCHITECTURAL WOODWORK INSTITUTE, 1997,

SEVENTH EDITION, VERSION 1.0.

B. BHMA A156.9 - AMERICAN NATIONAL STANDARD FOR CABINET

HARDWARE, BUILDERS HARDWARE MANUFACTURERS ASSOCIATION,

2003 (ANSI/BHMA A156.9).

C. NEMA LD 3 - HIGH-PRESSURE DECORATIVE LAMINATES, NATIONAL

ELECTRICAL MANUFACTURERS ASSOCIATION, 2000.

1.03 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS FOR

SUBMITTAL PROCEDURES.

B. SHOP DRAWINGS: INDICATE MATERIALS, COMPONENT PROFILES,

FASTENING METHODS, JOINTING DETAILS, AND ACCESSORIES TO A

MINIMUM SCALE OF 1-1/2 INCH TO 1 FT (1:8).

C. SAMPLES: SUBMIT TWO SAMPLES OF WOOD TRIM 6 INCHES LONG.

1.04 QUALITY ASSURANCE

1.05 DELIVERY, STORAGE, AND PROTECTION

A. PROTECT WORK FROM MOISTURE DAMAGE.

1.06 PROJECT CONDITIONS

A. SEQUENCE INSTALLATION TO ENSURE UTILITY CONNECTIONS ARE

ACHIEVED IN AN ORDERLY AND EXPEDITIOUS MANNER.

B. COORDINATE THE WORK WITH PLUMBING ROUGH-IN, ELECTRICAL

ROUGH-IN, AND INSTALLATION OF ASSOCIATED AND ADJACENT

COMPONENTS.

PART 2 PRODUCTS

2.01 PLASTIC LAMINATE MATERIALS

A. PLASTIC LAMINATE: NEMA LD 3, HGS, VGS, HGP AS REQUIRED TO SUIT

APPLICATION, COLOR AND TEXTURE AS INDICATED ON DRAWINGS.

B. LOW PRESSURE LAMINATE: MELAMINE, COLOR AS SPECIFIED ON

DRAWINGS, AND SURFACE TEXTURE AS SELECTED.

C. LAMINATE BACKING SHEET: NEMA LD 3, BKL, UNDECORATED PLASTIC

LAMINATE.

D. ADHESIVE: OF TYPES BEST SUITED TO INSTALLATION.

2.02 WOOD TRIM

A. SOFTWOOD LUMBER: GRADED IN ACCORDANCE WITH AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED,

CUSTOM, AVERAGE MOISTURE CONTENT OF 6 PERCENT, SPECIES

AND GRADE AS FOLLOWSINDICATED ON DRAWINGS.

B. HARDWOOD LUMBER: GRADED IN ACCORDANCE WITH AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED,

CUSTOM, AVERAGE MOISTURE CONTENT OF 6 PERCENT, SPECIES

AND GRADE AS FOLLOWS: CLEAR POPLAR.

2.03 FASTENERS

A. FASTENERS: OF SIZE AND TYPE TO SUIT APPLICATION.

B. CONCEALED JOINT FASTENERS: THREADED STEEL.

2.04 ACCESSORIES

A. LUMBER FOR SHIMMING, BLOCKING: SOFTWOOD LUMBER OF CEDAR

SPECIES.

B. PRIMER: ALKYD PRIMER SEALER TYPE.

C. WOOD FILLER: SOLVENT BASE, TINTED TO MATCH SURFACE FINISH

COLOR.

2.05 HARDWARE

A. HARDWARE: COMPLY WITH BHMA A156.9 AND AS INDICATED ON

DRAWINGS.

2.06 FABRICATION

A. SHOP ASSEMBLE WORK FOR DELIVERY TO SITE, PERMITTING

PASSAGE THROUGH BUILDING OPENINGS.

B. CAP EXPOSED PLASTIC LAMINATE FINISH EDGES WITH MATERIAL OF

SAME FINISH AND PATTERN.

C. WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS

WITH AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR

SCRIBING AND SITE CUTTING.

D. APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERRUPTED SHEETS

CONSISTENT WITH MANUFACTURED SIZES. FIT CORNERS AND JOINTS

HAIRLINE, SECURE WITH CONCEALED FASTENERS. SLIGHTLY BEVEL

ARISES. LOCATE COUNTER BUTT JOINTS MINIMUM 2 FEET (600 MM)

FROM SINK CUT-OUTS.

E. APPLY LAMINATE BACKING SHEET TO REVERSE FACE OF PLASTIC

LAMINATE FINISHED SURFACES.

F. SHOP ASSEMBLE CASEWORK FOR DELIVERY TO SITE IN UNITS EASILY

HANDLED AND TO PERMIT PASSAGE THROUGH BUILDING OPENINGS.

G. FIT SHELVES, DOORS, AND EXPOSED EDGES WITH MATCHING VENEER

EDGING OR AS DETAILED ON DRAWINGS. USE ONE PIECE FOR FULL

LENGTH ONLY.

H. DOOR AND DRAWER FRONTS: 3/4 INCH (19 MM) THICK, FLUSH

OVERLAY STYLE.

I. WHEN NECESSARY TO CUT AND FIT ON SITE, PROVIDE MATERIALS

WITH AMPLE ALLOWANCE FOR CUTTING. PROVIDE TRIM FOR

SCRIBING AND SITE CUTTING.

J. APPLY PLASTIC LAMINATE FINISH IN FULL UNINTERRUPTED SHEETS

CONSISTENT WITH MANUFACTURED SIZES. FIT CORNERS AND JOINTS

HAIRLINE, SECURE WITH CONCEALED FASTENERS. SLIGHTLY BEVEL

ARISES. LOCATE COUNTER BUTT JOINTS MINIMUM 2 FEET (600 MM)

FROM SINK CUT-OUTS.

K. APPLY LAMINATE BACKING SHEET TO REVERSE SIDE OF PLASTIC

LAMINATE FINISHED SURFACES.

L. FABRICATE METAL COUNTERTOP SURFACES PRESSURE GLUED TO

PARTICLE BOARD CORE BACKING WITHOUT VISIBLE JOINTS.

M. MECHANICALLY FASTEN BACK SPLASH TO COUNTERTOPS WITH STEEL

BRACKETS AT 16 INCHES (400 MM) ON CENTER.

2.07 SHOP FINISHING

A. SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS.

B. APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS.

C. ON ITEMS TO RECEIVE TRANSPARENT FINISHES, USE WOOD FILLER

WHICH MATCHES SURROUNDING SURFACES AND OF TYPES

RECOMMENDED FOR APPLIED FINISHES.

D. FINISH WORK IN ACCORDANCE WITH AWI ARCHITECTURAL

WOODWORK QUALITY STANDARDS ILLUSTRATED, SECTION 1500,

SYSTEM TR-2 (TRANSPARENT).

E. BACK PRIME WOODWORK ITEMS TO BE FIELD FINISHED, PRIOR TO

INSTALLATION.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY ADEQUACY OF BACKING AND SUPPORT FRAMING.

B. VERIFY MECHANICAL, ELECTRICAL, AND BUILDING ITEMS AFFECTING

WORK OF THIS SECTION ARE PLACED AND READY TO RECEIVE THIS

WORK.

C. SEE SECTION 061000-ROUGH CARPENTRY FOR INSTALLATION OF

RECESSED AND CONCEALED WOOD BLOCKING.

3.02 INSTALLATION

A. SET AND SECURE MATERIALS AND COMPONENTS IN PLACE, PLUMB

AND LEVEL.

B. CAREFULLY SCRIBE WORK ABUTTING OTHER COMPONENTS, WITH

MAXIMUM GAPS OF 1/32 INCH (1 MM). DO NOT USE ADDITIONAL

OVERLAY TRIM TO CONCEAL LARGER GAPS.

C. INSTALL COMPONENTS, FIXTURES AND TRIM WITH FASTENERS AND

ADHESIVES AS INDICATED ON FABRICATORS SHOP DRAWINGS.

PROVIDE MECHANICAL FASTENERS FOR THE INSTALLATION OF ALL

COMPONENTS, INCLUDING INSTALLATIONS USING ADHESIVES.

D. INSTALL HARDWARE.

3.03 PREPARATION FOR SITE FINISHING

A. SET EXPOSED FASTENERS. APPLY WOOD FILLER IN EXPOSED

FASTENER INDENTATIONS. SAND WORK SMOOTH.

B. SITE FINISHING: REFER TO SECTION 099100.

C. BEFORE INSTALLATION, PRIME PAINT SURFACES OF ITEMS OR

ASSEMBLIES TO BE IN CONTACT WITH CEMENTITIOUS MATERIALS.

3.04 ERECTION TOLERANCES

A. MAXIMUM VARIATION FROM TRUE POSITION: 1/16 INCH (1.5 MM).

B. MAXIMUM OFFSET FROM TRUE ALIGNMENT WITH ABUTTING

MATERIALS: 1/32 INCH (0.7 MM).

3.05 SCHEDULE

A. INSTALLATION SCHEDULE IS INDICATED ON DRAWINGS.

END OF SECTION

SECTION 066400 - PLASTIC PANELING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. PREFINISHED PANEL SYSTEM FOR ADHESIVE MOUNTING.

1.02 REFERENCES

A. ASTM E 84 - STANDARD TEST METHOD FOR SURFACE BURNING

CHARACTERISTICS OF BUILDING MATERIALS, 2001.

1.03 DELIVERY, STORAGE, AND HANDLING

A. STORE PRODUCTS IN MANUFACTURER'S UNOPENED PACKAGING

UNTIL READY FOR INSTALLATION.

B. STORE AND DISPOSE OF SOLVENT-BASED MATERIALS, AND

MATERIALS USED WITH SOLVENT-BASED MATERIALS, IN ACCORDANCE

WITH REQUIREMENTS OF LOCAL AUTHORITIES HAVING JURISDICTION.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. ACCEPTABLE MANUFACTURER: MARLITE, 202 HARGER STREET,

DOVER, OH 44622. ASD. TEL: (330) 343-6621. FAX: (330) 343-7296.

EMAIL: [email protected] WWW.MARLITE.COM

B. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT REQUIREMENTS.

2.02 PREFINISHED DECORATIVE PANEL SYSTEM

A. PREFINISHED PANEL SYSTEM: MARLITE FRP , CONSISTING OF

FACTORY FINISHED PANELS, TRIM, AND ACCESSORIES.

1. PANELS: AS SPECIFIED BELOW.

2. PANEL THICKNESS: 3/32 INCH.

3. PANEL SIZE: 48 INCHES WIDE X 96" OR 120" AS REQUIRED ON

PROJECT, USE FULL HEIGHT PANEL WHERE POSSIBLE.

4. SUPPORT SYSTEM: NONE, ADHESIVE APPLIED.

5. COLOR: P-100 WHITE

B. PANEL TRIM: EXTRUDED PVC IN MANUFACTURERS STANDARD

COLORS. PROVIDE ALL OUTSIDE CORNERS, INSIDE CORNERS,

DIVISION TRIMS REQUIRED FOR COMPLETE INSTALLATION.

1. PROFILE: OUTSIDE CORNERS, INSIDE CORNERS, AND EDGE

TRIM, MINIMUM 10 FOOT (3050 MM) LENGTH.

2. FOR 3/4 INCH (19 MM) PANELS: NARROWLINE TRIM.

3. FOR 1/4 INCH (6 MM) PANELS: FLAT PERIMETER EDGE TRIM

AND SHADOWLINE CORNERS AND BATTENS.

4. FINISH: CLEAR SATIN ANODIZED ALUMINUM.

C. SEALANT: MARLITE SILICONE SEALANT, GUNNABLE SILICONE RUBBER,

COLOR WHITE

PART 3 EXECUTION

3.01 EXAMINATION

A. DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE BEEN

PROPERLY PREPARED.

B. IF SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF ANOTHER

INSTALLER, NOTIFY ARCHITECT OF UNSATISFACTORY PREPARATION

BEFORE PROCEEDING.

C. DO NOT BEGIN INSTALLATION UNTIL BUILDING IS COMPLETELY

ENCLOSED AND INTERIOR CONDITIONS ARE BEING MAINTAINED AS

INTENDED DURING OCCUPANCY, APPROXIMATELY 70 DEGREES F (21

DEGREES C).

3.02 PREPARATION

A. OPEN CARTONS AND ALLOW PRODUCT TO ACCLIMATIZE TO ROOM

CONDITIONS FOR AT LEAST 48 HOURS PRIOR TO INSTALLATION.

B. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE

MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE

SUBSTRATE UNDER THE PROJECT CONDITIONS.

C. CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION.

D. PROTECT EXISTING SURFACES FROM DAMAGE DUE TO INSTALLATION.

3.03 INSTALLATION

A. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

B. USE THE ADHESIVES RECOMMENDED BY THE PANEL MANUFACTURER

UNLESS PROHIBITED BY LOCAL REGULATIONS, OBTAIN

MANUFACTURER'S APPROVAL OF ALTERNATIVE ADHESIVES.

C. APPLY CONTINUOUS BEAD OF SEALANT IN CHANNEL OF EACH JOINT

AND TRIM PIECE AND AT JOINT BETWEEN TRIM AND ADJACENT

CONSTRUCTION, MAINTAIN 1/8" EXPANSION SPACE AT ALL JOINTS.

D. AVOID CONTAMINATION OR DAMAGE OF PANEL FACES, CLEAN AS

NECESSARY AND REPLACE IF NOT POSSIBLE TO REPAIR TO ORIGINAL

CONDITION.

E. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT.

F. TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS AFTER

SUBSTANTIAL COMPLETION.

END OF SECTION

SECTION 072100 - THERMAL INSULATION

PART 1 GENERAL

1.01 SECTION INCLUDES

A. BOARD INSULATION AT EXTERIOR WALL BEHIND INTERIOR GYPSUM

BOARD WALL FINISH.

B. BATT INSULATION AND VAPOR RETARDER IN EXTERIOR WALL

CONSTRUCTION AND INTERIOR WALLS.

C. BATT INSULATION FOR FILLING CREVICES IN EXTERIOR WALL AND

ROOF.

D. SOUND INSULATION FOR DEMISING WALLS AT PUBLIC PET WASH OR

GROOMING AREAS.

1.02 REFERENCES

A. ASTM C 578 - STANDARD SPECIFICATION FOR RIGID, CELLULAR

POLYSTYRENE THERMAL INSULATION, 2001.

B. ASTM C 665 - STANDARD SPECIFICATION FOR MINERAL-FIBER

BLANKET THERMAL INSULATION FOR LIGHT FRAME CONSTRUCTION

AND MANUFACTURED HOUSING, 2001.

1.03 ENVIRONMENTAL REQUIREMENTS

A. DO NOT INSTALL INSULATION ADHESIVES WHEN TEMPERATURE OR

WEATHER CONDITIONS ARE DETRIMENTAL TO SUCCESSFUL

INSTALLATION.

PART 2 PRODUCTS

2.01 BOARD INSULATION MATERIALS

A. EXTRUDED POLYSTYRENE BOARD INSULATION: ASTM C 578, TYPE IV,

EXTRUDED POLYSTYRENE BOARD WITH EITHER NATURAL SKIN OR

CUT CELL SURFACES, WITH THE FOLLOWING CHARACTERISTICS:

1. BOARD SIZE: 24 X 96 INCH (1220 X 2440 MM).

2. BOARD THICKNESS: THICKNESS IN INCHES ( MM) AS

INDICATED ON DRAWINGS..

3. BOARD EDGES: SQUARE.

4. COMPRESSIVE RESISTANCE: 15 PSI (173 KPA).

5. BOARD DENSITY: 1.3 LB/CU FT (21 KG/CU M).

6. MANUFACTURERS:

a. DOW CHEMICAL CO: WWW.DOW.COM, STYROFOAM

Z-MATE.

b. OWENS CORNING CORP: WWW.OWENSCORNING.COM.

c. PACTIV BUILDING PRODUCTS:

WWW.PACTIVBUILDINGPRODUCTS.COM.

7. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT

REQUIREMENTS.

2.02 BATT INSULATION MATERIALS

A. BATT INSULATION: ASTM C 665, PREFORMED GLASS FIBER BATT FOR

THERMAL AND SOUND ATTENUATION APPLICATIONS, FRICTION FIT,

CONFORMING TO THE FOLLOWING:

1. THICKNESS: AS INDICATED.

2. MANUFACTURERS:

a. CERTAINTEED CORPORATION: WWW.CERTAINTEED.COM.

b. JOHNS MANVILLE CORPORATION: WWW.JM.COM.

c. OWENS CORNING CORP: WWW.OWENSCORNING.COM.

3. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT

REQUIREMENTS.

2.03 SOUND ATTENUATION BATTS

A. TYPE: UNFACED GLASS FIBER ACOUSTICAL INSULATION COMPLYING

WITH ASTM C665, TYPE 1.

B. SIZE:

THICKNESS WIDTH LENGTH

3½" 89MM 16" 406MM 24" 609MM 96" 2438MM

2½" 64MM 16" 406MM 24" 609MM 96" 2438MM

C. SIZE:SURFACE BURNING CHARACTERISTICS:

1. MAXIMUM FLAME SPREAD. 10

2. MAXIMUM SMOKE DEVELOPED: 10

WHEN TESTED IN ACCORDANCE WITH ASTM E 84.

D. COMBUSTION CHARACTERISTICS: PASSES ASTM E 136.

E. FIRE RESISTANCE RATINGS: PASSES ASTM E 119 AS PART OF A

COMPLETE FIRE TESTED WALL ASSEMBLY.

F. SOUND TRANSMISSION CLASS: STC50

G. DIMENSIONAL STABILITY: LINEAR SHRINKAGE LESS THAN 0.1%

H. MANUFACTURERS:

a. DOW CHEMICAL CO: WWW.DOW.COM, STYROFOAM

Z-MATE.

b. OWENS CORNING CORP: WWW.OWENSCORNING.COM.

c. PACTIV BUILDING PRODUCTS:

WWW.PACTIVBUILDINGPRODUCTS.COM.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT SUBSTRATE, ADJACENT MATERIALS, AND INSULATION

MATERIALS ARE DRY AND THAT SUBSTRATES ARE READY TO RECEIVE

INSULATION.

B. VERIFY SUBSTRATE SURFACES ARE FLAT, FREE OF IRREGULARITIES.

3.02 BOARD INSTALLATION AT EXTERIOR WALLS

A. APPLY ADHESIVE TO BACK OF BOARDS:

B. INSTALL BOARDS VERTICALLY ON WALLS.

6. PLACE BOARDS TO MAXIMIZE ADHESIVE CONTACT.

C. CUT AND FIT INSULATION TIGHTLY TO PROTRUSIONS OR

INTERRUPTIONS TO THE INSULATION PLANE.

3.03 BATT INSTALLATION

A. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

B. INSTALL IN EXTERIOR WALL AND ROOF SPACES WITHOUT GAPS OR

VOIDS. DO NOT COMPRESS INSULATION.

C. TRIM INSULATION NEATLY TO FIT SPACES. INSULATE MISCELLANEOUS

GAPS AND VOIDS.

D. FIT INSULATION TIGHTLY IN CAVITIES AND TIGHTLY TO EXTERIOR SIDE

OF MECHANICAL AND ELECTRICAL SERVICES WITHIN THE PLANE OF

THE INSULATION.

3.04 PROTECTION OF FINISHED WORK

A. DO NOT PERMIT INSTALLED INSULATION TO BE DAMAGED PRIOR TO

ITS CONCEALMENT.

END OF SECTION

SECTION 077100 - ROOFING

PART 1 GENERAL

1.01 ROOF IS EXISTING. ALL WORK SHALL BE IN CONFORMANCE WITH THE

LANDLORD ROOF SYSTEM MANUFACTURER'S SPECIFICATIONS REQUIRED

TO MAINTAIN WARRANTY.

1.02 ALL ROOF WORK TO BE PERFORMED BY LANDLORD ROOFING

CONTRACTOR.

PART 2 PRODUCTS

2.01 PROVIDE ALL INSULATION, ROOF MEMBRANE, FLASHING, ADHEASIVES AND

FASTENERS REQUIRED TO PROVIDE A COMPLETE INSTALLATION.

2.2. PROVIDE BUILT-UP CRICKETS AND SADDLES TO PROVIDE POSITIVE

DRAINAGE AROUND ROOF MOUNTED EQUIPMENT.

PART 3 EXECUTION

3.01 PROTECT EXISTING ROOF SYSTEM FROM DAMAGE DURING CONSTRUCTION.

3.02 INSTALL WORK IN ACCORDANCE WITH MANUFACTURER'S WRITTEN

INSTRUCTIONS AND DETAILS.

3.03 INSTALL INSULATION IN FULL THICKNESS AT ALL ROOF OPENINGS.

END OF SECTION

SECTION 079200 - JOINT SEALANTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. SEALANTS AND JOINT BACKING.

B. PRECOMPRESSED FOAM SEALERS.

1.02 REFERENCES

A. ASTM C 920 - STANDARD SPECIFICATION FOR ELASTOMERIC JOINT

SEALANTS, 2002.

B. ASTM C 1193 - STANDARD GUIDE FOR USE OF JOINT SEALANTS, 2000.

C. ASTM D 1056 - STANDARD SPECIFICATION FOR FLEXIBLE CELLULAR

MATERIALS--SPONGE OR EXPANDED RUBBER, 2000.

D. ASTM D 1667 - STANDARD SPECIFICATION FOR FLEXIBLE CELLULAR

MATERIALS--VINYL CHLORIDE POLYMERS AND COPOLYMERS

(CLOSED-CELL FOAM), 1997.

E. ASTM D 2628 - STANDARD SPECIFICATION FOR PREFORMED

POLYCHLOROPRENE ELASTOMERIC JOINT SEALS FOR CONCRETE

PAVEMENTS, 1991 (REAPPROVED 1998).

1.03 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. PRODUCT DATA: PROVIDE DATA INDICATING SEALANT CHEMICAL

CHARACTERISTICS.

C. MANUFACTURERS COLOR SELECTION CHART FOR COLOR

VERIFICATION AT EXPOSED TO VIEW SEALANTS.

1.04 QUALITY ASSURANCE

A. MAINTAIN ONE COPY OF EACH REFERENCED DOCUMENT COVERING

INSTALLATION REQUIREMENTS ON SITE.

B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN

PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 3 YEARS

EXPERIENCE.

1.05 ENVIRONMENTAL REQUIREMENTS

A. MAINTAIN TEMPERATURE AND HUMIDITY RECOMMENDED BY THE

SEALANT MANUFACTURER DURING AND AFTER INSTALLATION.

1.06 WARRANTY

A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL

WARRANTY REQUIREMENTS.

B. CORRECT DEFECTIVE WORK WITHIN A FIVE YEAR PERIOD AFTER DATE

OF SUBSTANTIAL COMPLETION.

C. WARRANTY: INCLUDE COVERAGE FOR INSTALLED SEALANTS AND

ACCESSORIES WHICH FAIL TO ACHIEVE AIRTIGHT SEAL

D. GENERAL WARANTY: SPECIAL WARRANTIES SPECIFIED IN THIS

ARTICLE SAHLL NOT DEPRIEVE THE OWNER OF OTHER RIGHTS THE

OWNER MAY HAVE UNDER OTHER PROVISIONS OF THE CONTRACT

DOCUMENTS AND SHALL BE IN ADDITON TO AND RUM CONCURRENT

WITH THE OTHER WARRANTIES MADE BY THE CONTRACTOR UNDER

REQUIREMENTS OF THE CONTRACT DOCUMENTS.

E. SPECIAL INSTALLERS WARRANTY: WRITTEN WARRANTY SIRNED BY

THE INSTALLER AGEEING TO REPAIR OR REPLACE ELATOMERIC JOINT

SEALANTS THAT DO NOT COMPLY WITHTHE PERFORMANCE AND

OTHER REQUIREMENTS OF THIS SECTION WITHIN A WARRANTY

PERIOD OF TWO YEARS FOR THE DATE OF SUBSTANTIAL

COMPLETION.

F. SPECIAL MANUFACTURERS WARRANTY: WRITTEN WARRANTY SIGNED

BY THE MANUFACTURER AGEEING TO REPAIR OR REPLACE

ELATOMERIC JOINT SEALANTS THAT DO NOT COMPLY WITHTHE

PERFORMANCE AND OTHER REQUIREMENTS OF THIS SECTION WITHIN

A WARRANTY PERIOD OF FIVE YEARS FOR THE DATE OF SUBSTANTIAL

COMPLETION.

G. SPECIAL WARRANTIES SPECIFIED IN THIS THIS SECTION EXCLUDE

DETERIORATION OR FAILURE OF ELASTOMERIC SEALANT FROM THE

FOLLOWING:

1. MOVEMENT OF THE STRUCTURE FROM STRESSES ON THE

SEALANT THAT EXCEED THE SEALANT MANUFACTURERS

WRITTEN SPECIFICATIONS FOR SEALANT ELONGATION AND

COMPRESSION CAUSED BY STRUCTURAL SETTLEMENT OR

ERRORS ATTRIBUTABLE TO DESIGN AND CONSTRUCTION.

2. DISINTEGRATION OF JOINT SUBSTRATES FROM NATURAL

CAUSES EXCEEDING DESIGN SPECIFICATIONS.

3. MECHANICAL DAMAGE CAUSED BY INDIVIDUALS, TOOLS, OR

OTHER OUTSIDE AGENTS.

4. CHANGES IN THE SEALANT APPEARANCE CAUSED BY THE

ACCUMULATION OF DIRT OR OTHER ATMOSPHERIC

CONTAMINANTS.

PART 2 PRODUCTS

2.01 EXTERIOR SEALANTS

A. PROVIDE ONE OR TWO COMPONENT ALIPHATIC URETHANE WHER

WHITE OR CUSTOM COLOR IS REQUIRED AND FOR VINYL TO VINYL

WITH PRIMER, MASONRY TO MASONRY INCLUDIING CONTROL JOINTS,

ALUMINUM TO MASONRY WITH PRIMER ON ALUMINUM AND FOR EIFS

APPLICATIONS.

1. USE ONE PRODUCT FOR THE ENTIRE JOB.

2. PRODUCTS: WHEN WHITE COLOR IS REQUIRED.

a. WHEN WHITE COLOR IS REQUIRED. ULTRA BY

SONNEBORN

3. PROVIDE ONE OF THE FOLLOWING WHEN NON WHITE COLOR IS

SELECTED.

a. SONOLASTIC NP 2 BY SONNEBORN

b. DYNATROL II BY PECORA

c. CHE-CALK 500 BY BOSTIC

d. DYMERIC 511 BY TREMCO

B. PROVIDE ONE PART POLYETHER, MODIFIED SILICONE,

SIL-TERMINATED NON-SAG ELASTOMERIC SEALANT FOR METAL TO

METAL , METAL TO GLASS, GLASS TO GLASS, FERROUS METAL TO

VINYL, VINYL TO VINYL.

1. PRODUCTS:

a. SONOLASTIC 150 BY SONNEBORN

b. DOW CORNING 790 BY DOW CORNING

c. SILPUR SEALANT BY GE SILICONES

C. PROVIDE TWO PART POLYURETHANE SELF LEVLEING SEALANT FOR

EXTERIOR AND INTERIOR EXPANSION AND CONTROL JOINTS IN

HORIZONTAL WEARING SURFACES.

1. PRODUCTS

a. SONOLASTIC SL 2 BY SONNEBORN

b. DYNATRED BY PECORA

C. CHEM CALK 550 BY BOSTIK

D. PROVIDE ONE COMPONENT HIGH PERFORMANCE POLYURETHANE

SEALANT FOR INTERIOR SEALANT IN CONTACT WITH EXTERIOR

ALUMINUM STOREFRONT, DOORS AND FRAMES.

1. PRODUCTS

a. SONOLASTIC NP1 BY SONNEBORN

b. DYNATROL 1 BY PECORA

c. CHEM-CALK 2639 BY BOSTIK

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT SUBSTRATE SURFACES ARE READY TO RECEIVE WORK.

B. VERIFY THAT JOINT BACKING AND RELEASE TAPES ARE COMPATIBLE

WITH SEALANT.

3.02 PREPARATION

A. REMOVE LOOSE MATERIALS AND FOREIGN MATTER WHICH MIGHT

IMPAIR ADHESION OF SEALANT.

B. CLEAN AND PRIME JOINTS IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

C. PERFORM PREPARATION IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS AND ASTM C 1193.

D. PROTECT ELEMENTS SURROUNDING THE WORK OF THIS SECTION

FROM DAMAGE OR DISFIGUREMENT.

3.03 INSTALLATION

A. PERFORM WORK IN ACCORDANCE WITH SEALANT MANUFACTURER'S

REQUIREMENTS FOR PREPARATION OF SURFACES AND MATERIAL

INSTALLATION INSTRUCTIONS.

B. PERFORM INSTALLATION IN ACCORDANCE WITH ASTM C 1193.

C. MEASURE JOINT DIMENSIONS AND SIZE JOINT BACKERS TO ACHIEVE

WIDTH-TO-DEPTH RATIO, NECK DIMENSION, AND SURFACE BOND

AREA AS RECOMMENDED BY MANUFACTURER.

D. INSTALL BOND BREAKER WHERE JOINT BACKING IS NOT USED. E.

INSTALL SEALANT FREE OF AIR POCKETS, FOREIGN EMBEDDED

MATTER, RIDGES, AND SAGS.

F. APPLY SEALANT WITHIN RECOMMENDED APPLICATION TEMPERATURE

RANGES. CONSULT MANUFACTURER WHEN SEALANT CANNOT BE

APPLIED WITHIN THESE TEMPERATURE RANGES.

G. TOOL JOINTS CONCAVE.

3.04 CLEANING

A. CLEAN ADJACENT SOILED SURFACES.

3.05 PROTECTION OF FINISHED WORK

A. PROTECT SEALANTS UNTIL CURED.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.3

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.3

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 10: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 081113 - HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. NON-FIRE-RATED STEEL DOORS AND FRAMES.

B. STEEL FRAMES FOR WOOD DOORS.

C. THERMALLY INSULATED STEEL DOORS.

D. ACCESSORIES, INCLUDING GLAZING, LOUVERS, AND MATCHING

PANELS.

1.02 REFERENCES

A. ANSI/ICC A117.1 - AMERICAN NATIONAL STANDARD FOR ACCESSIBLE

AND USABLE BUILDINGS AND FACILITIES, INTERNATIONAL CODE

COUNCIL, 1998.

B. ANSI A250.8 - SDI-100 RECOMMENDED SPECIFICATIONS FOR

STANDARD STEEL DOORS AND FRAMES, 1998.

C. ANSI A250.10 - TEST PROCEDURE AND ACCEPTANCE CRITERIA FOR

PRIME PAINTED STEEL SURFACES FOR STEEL DOORS AND FRAMES,

1998.

D. ASTM A 653/A 653M - STANDARD SPECIFICATION FOR STEEL SHEET,

ZINC-COATED (GALVANIZED) OR ZINC-IRON ALLOY-COATED

(GALVANNEALED) BY THE HOT-DIP PROCESS, 2002A

E. ASTM C 236 - STANDARD TEST METHOD FOR STEADY-STATE

THERMAL PERFORMANCE OF BUILDING ASSEMBLIES BY MEANS OF A

GUARDED HOT BOX, 1989 (REAPPROVED 1993).

F. ASTM C 1363 - STANDARD TEST METHOD FOR THERMAL

PERFORMANCE OF BUILDING ASSEMBLIES BY MEANS OF A HOT BOX

APPARATUS, 1997.

G. DHI A115 SERIES - SPECIFICATIONS FOR STEEL DOORS AND FRAME

PREPARATION FOR HARDWARE, DOOR AND HARDWARE INSTITUTE,

CURRENT EDITION (ANSI/DHI A115 SERIES).

H. NAAMM HMMA 840 - INSTALLATION AND STORAGE OF HOLLOW METAL

DOORS AND FRAMES, THE NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL MANUFACTURERS, 1999.

I. NAAMM HMMA 860 - GUIDE SPECIFICATIONS FOR HOLLOW METAL

DOORS AND FRAMES, THE NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL MANUFACTURERS, 1992.

J. NFPA 80 - STANDARD FOR FIRE DOORS AND FIRE WINDOWS,

NATIONAL FIRE PROTECTION ASSOCIATION, 1999.

K. NFPA 252 - STANDARD METHODS OF FIRE TESTS OF DOOR

ASSEMBLIES, NATIONAL FIRE PROTECTION ASSOCIATION, 1999.

L. UL (BMD) - BUILDING MATERIALS DIRECTORY, UNDERWRITERS

LABORATORIES INC., CURRENT EDITION.

1.03 QUALITY ASSURANCE

A. MAINTAIN AT THE PROJECT SITE A COPY OF ALL REFERENCE

STANDARDS DEALING WITH INSTALLATION.

1.04 DELIVERY, STORAGE, AND PROTECTION

A. STORE IN ACCORDANCE WITH NAAMM HMMA 840.

B. PROTECT WITH RESILIENT PACKAGING, AVOID HUMIDITY BUILD-UP

UNDER COVERINGS, PREVENT CORROSION.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. STEEL DOORS AND FRAMES:

1. STEELCRAFT, PRODUCT BF16: WWW.STEELCRAFT.COM.

2. CECO DOOR PRODUCTS: WWW.CECODOOR.COM.

3. REPUBLIC BUILDERS PRODUCTS:

WWW.REPUBLICDOOR.COM.

4. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT

REQUIREMENTS.

2.02 DOORS AND FRAMES

A. REQUIREMENTS FOR ALL DOORS AND FRAMES:

1. ACCESSIBILITY: COMPLY WITH ANSI/ICC A117.1.

2. DOOR TOP CLOSURES: EXTERIOR DOORS SHALL BE FLUSH

WITH TOP OF FACES AND EDGES.

3. DOOR EDGE PROFILE: BEVELED ON BOTH EDGES.

4. DOOR TEXTURE: SMOOTH FACES.

5. HARDWARE PREPARATION: IN ACCORDANCE WITH DHI A115

SERIES, WITH REINFORCEMENT WELDED IN PLACE, IN

ADDITION TO OTHER REQUIREMENTS SPECIFIED IN DOOR

GRADE STANDARD.

6. GALVANIZING FOR EXTERIOR DOORS: ALL COMPONENTS

HOT-DIPPED ZINC-IRON ALLOY-COATED (GALVANNEALED),

MANUFACTURER'S STANDARD COATING THICKNESS.

7. FINISH: FACTORY PRIMED, FOR FIELD FINISHING.

B. COMBINED REQUIREMENTS: IF A PARTICULAR DOOR AND FRAME

UNIT IS INDICATED TO COMPLY WITH MORE THAN ONE TYPE OF

REQUIREMENT, COMPLY WITH ALL THE SPECIFIED REQUIREMENTS

FOR EACH TYPE, FOR INSTANCE, AN EXTERIOR DOOR THAT IS ALSO

INDICATED AS BEING SOUND-RATED MUST COMPLY WITH THE

REQUIREMENTS SPECIFIED FOR EXTERIOR DOORS AND FOR

SOUND-RATED DOORS, WHERE TWO REQUIREMENTS CONFLICT,

COMPLY WITH THE MOST STRINGENT.

2.03 STEEL DOORS

A. EXTERIOR DOORS:

1. GRADE: ANSI A250.8 LEVEL 3, MODEL 2, FULL FLUSH

SEAMLESS.

2. CORE: POLYURETHANE.

3. TOP AND BOTTOM CLOSURES: FLUSH WITH FACES AND

EDGES.

4. GALVANIZING: ALL COMPONENTS HOT-DIPPED ZINC-IRON

ALLOY-COATED (GALVANNEALED) IN ACCORDANCE WITH

ASTM A 653/A 653M, WITH MANUFACTURER'S STANDARD

COATING THICKNESS.

5. TEXTURE: SMOOTH FACES.

6. INSULATING VALUE: U-VALUE OF ,WHEN TESTED IN

ACCORDANCE WITH ASTM C 1363.

7. WEATHERSTRIPPING: SEPARATE, SEE SECTION 087100.

8. FINISH: FACTORY PRIMED, FOR FIELD FINISHING.

B. INTERIOR DOORS:

1. GRADE: ANSI A250.8 LEVEL 2, MODEL 1, FLUSH.

2. GRADE: NAAMM HMMA 860, PHYSICAL PERFORMANCE LEVEL

A.

3. CORE: STEEL STIFFENERS.

4. THICKNESS: 1-3/4 INCHES (44 MM).

5. TEXTURE: SMOOTH FACES.

6. FINISH: FACTORY PRIMED, FOR FIELD FINISHING.

C. PANELS: SAME CONSTRUCTION, PERFORMANCE, AND FINISH AS

DOORS.

2.04 STEEL FRAMES

A. GENERAL:

1. COMPLY WITH THE REQUIREMENTS OF GRADE SPECIFIED

FOR CORRESPONDING DOOR.

a. ANSI A250.8 LEVEL 2 DOORS: 16 GAGE FRAMES; LEVEL 3

DOOR 16 GA.

2. FINISH: SAME AS FOR DOOR.

3. PROVIDE MORTAR GUARD BOXES FOR HARDWARE CUT-OUTS

IN FRAMES TO BE INSTALLED IN MASONRY OR TO BE

GROUTED.

4. FRAMES IN MASONRY WALLS: SIZE TO SUIT MASONRY

COURSING WITH HEAD MEMBER TO FILL OPENING WITHOUT

CUTTING MASONRY UNITS.

B. EXTERIOR DOOR FRAMES: FACE WELDED, SEAMLESS WITH JOINTS

FILLED.

1. GALVANIZING: ALL COMPONENTS HOT-DIPPED ZINC-IRON

ALLOY-COATED (GALVANNEALED) IN ACCORDANCE WITH

ASTM A 653/A 653M, WITH MANUFACTURER'S STANDARD

COATING THICKNESS.

2. WEATHERSTRIPPING: SEPARATE, SEE SECTION 087100.

C. INTERIOR DOOR FRAMES, FIRE-RATED: DRYWALL SLIP-ON TYPE OR

FACE WELDED AT MASONRY WALL CONSTRUCTION.

1. FIRE RATING: SAME AS DOOR, LABELED.

D. FRAMES FOR INTERIOR GLAZING OR BORROWED LIGHTS:

CONSTRUCTION AND FACE DIMENSIONS TO MATCH DOOR FRAMES,

AND AS INDICATED ON DRAWINGS.

2.05 ACCESSORY MATERIALS

A. LOUVERS: ROLL FORMED STEEL WITH OVERLAPPING FRAME,

FACTORY-PAINTED FINISH, COLOR AS SELECTED,

FACTORY-INSTALLED.

1. IN FIRE-RATED DOORS: UL-LISTED FUSIBLE LINK LOUVER,

SAME RATING AS DOOR.

B. GROUT FOR FRAMES: PORTLAND CEMENT GROUT OF MAXIMUM

4-INCH SLUMP FOR HAND TROWELING, THINNER PUMPABLE GROUT

IS PROHIBITED.

C. SILENCERS: RESILIENT RUBBER, FITTED INTO DRILLED HOLE, 3 ON

STRIKE SIDE OF SINGLE DOOR, 3 ON CENTER MULLION OF PAIRS,

AND 2 ON HEAD OF PAIRS WITHOUT CENTER MULLIONS.

D. TEMPORARY FRAME SPREADERS: PROVIDE FOR ALL FACTORY- OR

SHOP-ASSEMBLED FRAMES.

2.06 FINISH MATERIALS

A. PRIMER: RUST-INHIBITING, COMPLYING WITH ANSI A250.10, DOOR

MANUFACTURER'S STANDARD.

B. BITUMINOUS COATING: ASPHALT EMULSION OR OTHER HIGH-BUILD,

WATER-RESISTANT, RESILIENT COATING.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK.

B. VERIFY THAT OPENING SIZES AND TOLERANCES ARE ACCEPTABLE.

3.02 PREPARATION

A. COAT INSIDE OF FRAMES TO BE INSTALLED IN MASONRY OR TO BE

GROUTED, WITH BITUMINOUS COATING, PRIOR TO INSTALLATION.

3.03 INSTALLATION

A. INSTALL IN ACCORDANCE WITH THE REQUIREMENTS OF THE

SPECIFIED DOOR GRADE STANDARD AND NAAMM HMMA 840.

B. IN ADDITION, INSTALL FIRE RATED UNITS IN ACCORDANCE WITH

NFPA 80.

C. COORDINATE FRAME ANCHOR PLACEMENT WITH WALL

CONSTRUCTION.

D. GROUT FRAMES IN MASONRY CONSTRUCTION, USING HAND TROWEL

METHODS, BRACE FRAMES SO THAT PRESSURE OF GROUT BEFORE

SETTING WILL NOT DEFORM FRAMES. SET FOAM SPACERS BLOCK AT

SILENCER HOLES.

E. COORDINATE INSTALLATION OF HARDWARE.

F. COORDINATE INSTALLATION OF GLAZING.

3.04 ERECTION TOLERANCES

A. CLEARANCES BETWEEN DOOR AND FRAME: AS SPECIFIED IN ANSI

A250.8.

B. MAXIMUM DIAGONAL DISTORTION: 1/16 IN (1.5 MM) MEASURED WITH

STRAIGHT EDGE, CORNER TO CORNER.

3.05 ADJUSTING

A. ADJUST FOR SMOOTH AND BALANCED DOOR MOVEMENT.

3.06 SCHEDULE

A. REFER TO DOOR AND FRAME SCHEDULE ON THE DRAWINGS.

END OF SECTION

SECTION 081416 - FLUSH WOOD DOORS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. FLUSH WOOD DOORS, FLUSH CONFIGURATION, FIRE RATED AND

NON-RATED.

1.02 REFERENCES

A. AWI (QSI) - ARCHITECTURAL WOODWORK QUALITY STANDARDS

ILLUSTRATED, ARCHITECTURAL WOODWORK INSTITUTE, 1997,

SEVENTH EDITION, VERSION 1.0.

B. WDMA NWWDA I.S.1-A - ARCHITECTURAL WOOD FLUSH DOORS,

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (FORMERLY

NWWDA), 1997.

1.03 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS FOR

SUBMITTAL PROCEDURES.

B. PRODUCT DATA: INDICATE DOOR CORE MATERIALS AND

CONSTRUCTION, VENEER SPECIES, TYPE AND CHARACTERISTICS.

1.04 QUALITY ASSURANCE

A. MANUFACTURER: COMPANY SPECIALIZING IN MANUFACTURING THE

PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE

YEARS OF DOCUMENTED EXPERIENCE.

1.05 DELIVERY, STORAGE, AND PROTECTION

A. PACKAGE, DELIVER AND STORE DOORS IN ACCORDANCE WITH

SPECIFIED QUALITY STANDARD.

B. ACCEPT DOORS ON SITE IN MANUFACTURER'S PACKAGING. INSPECT

FOR DAMAGE.

C. PROTECT DOORS WITH RESILIENT PACKAGING SEALED WITH HEAT

SHRUNK PLASTIC. DO NOT STORE IN DAMP OR WET AREAS, OR IN

AREAS WHERE SUNLIGHT MIGHT BLEACH VENEER. SEAL TOP AND

BOTTOM EDGES WITH TINTED SEALER IF STORED MORE THAN ONE

WEEK. BREAK SEAL ON SITE TO PERMIT VENTILATION.

1.06 PROJECT CONDITIONS

A. COORDINATE THE WORK WITH DOOR OPENING CONSTRUCTION,

DOOR FRAME AND DOOR HARDWARE INSTALLATION.

1.07 WARRANTY

A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS FOR ADDITIONAL

WARRANTY REQUIREMENTS.

B. PROVIDE WARRANTY FOR THE FOLLOWING TERM:

1. INTERIOR DOORS: TWO (2) YEARS.

C. INCLUDE COVERAGE FOR DELAMINATION OF VENEER, WARPING

BEYOND SPECIFIED INSTALLATION TOLERANCES, DEFECTIVE

MATERIALS, AND TELEGRAPHING CORE CONSTRUCTION

PART 2 PRODUCTS

2.01 DOORS AND PANELS

A. ALL DOORS: SEE DRAWINGS FOR LOCATIONS AND ADDITIONAL

REQUIREMENTS.

1. QUALITY STANDARD: WDMA I.S. 1-A, ECONOMY GRADE.

2. WOOD VENEER FACED DOORS: 5-PLY UNLESS OTHERWISE

INDICATED.

B. INTERIOR DOORS: 1-3/4 INCHES (44 MM) THICK UNLESS OTHERWISE

INDICATED, FLUSH CONSTRUCTION.

1. PROVIDE SOLID CORE DOORS AT ALL LOCATIONS EXCEPT

PROVIDE HOLLOW CORE DOORS AT LOCATIONS INDICATED

ON DRAWINGS.

2.02 DOOR AND PANEL CORES

A. NON-RATED SOLID CORE AND 20 MINUTE RATED DOORS: TYPE SLC,

STAVED LUMBER CORE, PLIES AND FACES AS INDICATED ABOVE.

B. HOLLOW CORE DOORS: TYPE SHC - STANDARD, PLIES AND FACES

AS INDICATED ABOVE.

2.03 DOOR FACINGS

A. WOOD VENEER FACING FOR TRANSPARENT FINISH: NATURAL BIRCH,

VENEER GRADE AS SPECIFIED BY QUALITY STANDARD, QUARTER

SLICED, BOOK VENEER MATCH, RUNNING ASSEMBLY MATCH, UNLESS

OTHERWISE INDICATED.

1. VERTICAL EDGES: COMPATIBLE HARDWOOD.

B. VENEER FACING FOR OPAQUE FINISH: MEDIUM DENSITY OVERLAID

PLYWOOD.

2.04 ACCESSORIES

2.05 DOOR CONSTRUCTION

A. FABRICATE DOORS IN ACCORDANCE WITH DOOR QUALITY

STANDARD SPECIFIED.

B. PROVIDE SOLID BLOCKS AT LOCK EDGE FOR HARDWARE

REINFORCEMENT.

C. FIT DOOR EDGE TRIM TO EDGE OF STILES AFTER APPLYING VENEER

FACING.

D. PROVIDE EDGE CLEARANCES IN ACCORDANCE WITH AWI QUALITY

STANDARDS ILLUSTRATED SECTION 1700.

2.06 FACTORY FINISHING

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK.

B. VERIFY THAT OPENING SIZES AND TOLERANCES ARE ACCEPTABLE.

C. DO NOT INSTALL DOORS IN FRAME OPENINGS THAT ARE NOT PLUMB

OR ARE OUT-OF-TOLERANCE FOR SIZE OR ALIGNMENT.

3.02 INSTALLATION

A. INSTALL DOORS IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS AND SPECIFIED QUALITY STANDARD.

B. TRIM NON-RATED DOOR WIDTH BY CUTTING EQUALLY ON BOTH JAMB

EDGES.

C. TRIM DOOR HEIGHT BY CUTTING BOTTOM EDGES TO A MAXIMUM OF

3/4 INCH (19 MM).

D. USE MACHINE TOOLS TO CUT OR DRILL FOR HARDWARE.

E. COORDINATE INSTALLATION OF DOORS WITH INSTALLATION OF

FRAMES AND HARDWARE.

F. COORDINATE INSTALLATION OF GLAZING.

G. INSTALL DOOR LOUVERS PLUMB AND LEVEL.

3.03 INSTALLATION TOLERANCES

A. CONFORM TO SPECIFIED QUALITY STANDARD FOR FIT AND

CLEARANCE TOLERANCES.

B. CONFORM TO SPECIFIED QUALITY STANDARD FOR MAXIMUM

DIAGONAL DISTORTION.

3.04 ADJUSTING

A. ADJUST DOORS FOR SMOOTH AND BALANCED DOOR MOVEMENT.

B. ADJUST CLOSERS FOR FULL CLOSURE.

3.05 SCHEDULE - SEE DRAWINGS

END OF SECTION

SECTION 083613 - SECTIONAL DOORS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. STEEL SECTIONAL OVERHEAD DOORS.

B. ELECTRIC OPERATORS AND CONTROLS.

C. OPERATING HARDWARE, TRACKS, AND SUPPORT.

1.02 REFERENCES

A. ANSI/DASMA 102 AMERICAN NATIONAL STANDARD SPECIFICATIONS

FOR SECTIONAL OVERHEAD TYPE DOORS.

1.03 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH

PRODUCT TO BE USED, INCLUDING:

1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS.

2. STORAGE AND HANDLING REQUIREMENTS AND

RECOMMENDATIONS.

3. INSTALLATION METHODS.

C. SHOP DRAWINGS: INDICATE PLANS AND ELEVATIONS INCLUDING

OPENING DIMENSIONS AND REQUIRED TOLERANCES, CONNECTION

DETAILS, ANCHORAGE SPACING, HARDWARE LOCATIONS, AND

INSTALLATION DETAILS.

D. MANUFACTURER'S CERTIFICATES: CERTIFY PRODUCTS MEET OR

EXCEED SPECIFIED REQUIREMENTS.

E. OPERATION AND MAINTENANCE DATA.

1.04 QUALITY ASSURANCE

A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN

MANUFACTURING PRODUCTS SPECIFIED IN THIS SECTION WITH

MINIMUM FIVE YEARS DOCUMENTED EXPERIENCE.

B. INSTALLER QUALIFICATIONS: AUTHORIZED REPRESENTATIVE OF THE

MANUFACTURER WITH MINIMUM FIVE YEARS DOCUMENTED

EXPERIENCE.

C. PRODUCTS REQUIRING ELECTRICAL CONNECTION: LISTED AND

CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. ACCEPTABLE

TO AUTHORITY HAVING JURISDICTION AS SUITABLE FOR PURPOSE

SPECIFIED.

1.05 DELIVERY, STORAGE, AND HANDLING

A. STORE PRODUCTS IN MANUFACTURER'S UNOPENED LABELED

PACKAGING UNTIL READY FOR INSTALLATION.

B. PROTECT MATERIALS FROM EXPOSURE TO MOISTURE UNTIL READY

FOR INSTALLATION.

C. STORE MATERIALS IN A DRY, VENTILATED WEATHERTIGHT LOCATION

1.06 PROJECT CONDITIONS

A. PRE-INSTALLATION CONFERENCE: CONVENE A PRE-INSTALLATION

CONFERENCE JUST PRIOR TO COMMENCEMENT OF FIELD

OPERATIONS, TO ESTABLISH PROCEDURES TO MAINTAIN OPTIMUM

WORKING CONDITIONS AND TO COORDINATE THIS WORK WITH

RELATED AND ADJACENT WORK.

PART 2 PRODUCTS .

2.01 MANUFACTURERS

A. ACCEPTABLE MANUFACTURER: OVERHEAD DOOR CORP., 2501 S

STATE HWY. 121, SUITE 200, LEWISVILLE, TX 75067. ASD. TEL TOLL

FREE: (800) 275-3290. PHONE: (469) 549-7100. FAX: (972) 906-1499. WEB

SITE: WWW.OVERHEADDOOR.COM E-MAIL:

[email protected]

B. REQUESTS FOR SUBSTITUTIONS WILL BE CONSIDERED IN

ACCORDANCE WITH PROVISIONS OF SECTION 016000.

2.02 SECTIONAL OVERHEAD DOORS

A. SECTIONAL OVERHEAD STEEL DOORS: 416 SERIES STEEL DOORS BY

OVERHEAD DOOR CORPORATION. UNITS SHALL HAVE THE

FOLLOWING CHARACTERISTICS:

1. DOOR ASSEMBLY: STEEL DOOR ASSEMBLY WITH RABBETED

MEETING RAILS TO FORM WEATHERTIGHT JOINTS AND

PROVIDE FULL-WIDTH INTERLOCKING STRUCTURAL RIGIDITY.

a. PANEL THICKNESS: 2 INCHES (51 MM).

b. EXTERIOR SURFACE: FLUSH.

c. THERMAL VALUES: R-VALUE OF 8.56; U-VALUE OF 0.17.

d. SECTION MATERIAL: 16 GAUGE, GALVANIZED STEEL.

e. CENTER AND END STILES: 16 GAUGE STEEL.

f. SPRINGS:

1.) 10,000 CYCLES.

2. LOCK:

a. INTERIOR MOUNTED SLIDE LOCK.

3. WEATHERSTRIPPING:

a. FLEXIBLE BULB-TYPE STRIP AT BOTTOM SECTION.

b. FLEXIBLE JAMB SEALS.

c. FLEXIBLE HEADER SEAL.

7. TRACK: PROVIDE TRACK AS RECOMMENDED BY

MANUFACTURER TO SUIT LOADING REQUIRED AND

CLEARANCES AVAILABLE.

8. MANUAL OPERATION: PULL ROPE.

9. ELECTRIC MOTOR OPERATION: PROVIDE UL LISTED ELECTRIC

OPERATOR, SIZE AND TYPE AS RECOMMENDED BY

MANUFACTURER TO MOVE DOOR IN EITHER DIRECTION AT

NOT LESS THAN 2/3 FOOT NOR MORE THAN 1 FOOT PER

SECOND. OPERATOR SHALL MEET UL325/2010

REQUIREMENTS FOR CONTINUOUS MONITORING OF SAFETY

DEVICES.

a. ENTRAPMENT PROTECTION: REQUIRED FOR MOMENTARY

CONTACT, INCLUDES RADIO CONTROL OPERATION.

1.) PNEUMATIC SENSING EDGE UP TO 18 FEET (5.5 M) WIDE.

CONSTANT CONTACT ONLY COMPLYING WITH UL 325/2010.

b. OPERATOR CONTROLS:

1.) PUSH-BUTTON AND KEY OPERATED CONTROL STATIONS

WITH OPEN, CLOSE, AND STOP BUTTONS.

2.) SURFACE MOUNTING.

3.) INTERIOR LOCATION.

PART 3 EXECUTION

3.01 EXAMINATION

A. DO NOT BEGIN INSTALLATION UNTIL OPENINGS HAVE BEEN

PROPERLY PREPARED.

B. VERIFY WALL OPENINGS ARE READY TO RECEIVE WORK AND

OPENING DIMENSIONS AND TOLERANCES ARE WITHIN SPECIFIED

LIMITS.

C. VERIFY ELECTRICAL POWER IS AVAILABLE AND OF CORRECT

CHARACTERISTICS.

3.02 PREPARATION

A. CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION.

B. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE

MANUFACTURER FOR ACHIEVING THE BEST RESULTS FOR THE

SUBSTRATE UNDER THE PROJECT CONDITIONS.

3.03 INSTALLATION

A. INSTALL OVERHEAD DOORS AND TRACK IN ACCORDANCE WITH

APPROVED SHOP DRAWINGS AND THE MANUFACTURER'S PRINTED

INSTRUCTIONS..

B. COORDINATE INSTALLATION WITH ADJACENT WORK TO ENSURE

PROPER CLEARANCES AND ALLOW FOR MAINTENANCE.

C. ANCHOR ASSEMBLY TO WALL CONSTRUCTION AND BUILDING

FRAMING WITHOUT DISTORTION OR STRESS.

D. SECURELY BRACE DOOR TRACKS SUSPENDED FROM STRUCTURE.

SECURE TRACKS TO STRUCTURAL MEMBERS ONLY.

E. FIT AND ALIGN DOOR ASSEMBLY INCLUDING HARDWARE.

F. COORDINATE INSTALLATION OF ELECTRICAL SERVICE. COMPLETE

POWER AND CONTROLS WIRING FROM DISCONNECT TO UNIT

COMPONENTS..

3.04 CLEANING AND ADJUSTING

A. ADJUST DOORS ASSEMBLY TO SMOOTH OPERATION AND IN FULL

CONTACT WITH WEATHERSTRIPPING.

B. CLEAN DOORS, FRAMES AND GLASS.

C. REMOVE TEMPORARY LABELS AND VISIBLE MARKINGS.

3.05 PROTECTION OF FINISHED WORK

A. DO NOT PERMIT CONSTRUCTION TRAFFIC THROUGH OVERHEAD

DOOR OPENINGS AFTER ADJUSTMENT AND CLEANING.

B. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT.

C. TOUCH-UP DAMAGED COATINGS AND FINISHES AND REPAIR DAMAGE

BEFORE SUBSTANTIAL COMPLETION.

END OF SECTION

SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. ALUMINUM-FRAMED STOREFRONT, WITH VISION GLASS.

B. WEATHERSTRIPPING.

C. PERIMETER SEALANT.

1.02 RELATED SECTIONS

A. SECTION 079200 - JOINT SEALERS: PERIMETER SEALANT AND

BACK-UP MATERIALS.

B. SECTION 088000 - GLAZING: GLASS AND GLAZING ACCESSORIES.

1.03 REFERENCES

A. AA DAF-45 - DESIGNATION SYSTEM FOR ALUMINUM FINISHES, THE

ALUMINUM ASSOCIATION, INC., 2003.

B. AAMA CW-10 - CARE AND HANDLING OF ARCHITECTURAL ALUMINUM

FROM SHOP TO SITE, AMERICAN ARCHITECTURAL MANUFACTURERS

ASSOCIATION, 1997.

C. AAMA 611 - VOLUNTARY SPECIFICATION FOR ANODIZED

ARCHITECTURAL ALUMINUM, AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION, 1998.

D. ASTM B 221 - STANDARD SPECIFICATION FOR ALUMINUM AND

ALUMINUM-ALLOY EXTRUDED BARS, RODS, WIRE, PROFILES, AND

TUBES, 2002.

E. ASTM B 221M - STANDARD SPECIFICATION FOR ALUMINUM AND

ALUMINUM-ALLOY EXTRUDED BARS, RODS, WIRE, PROFILES, AND

TUBES (METRIC), 2002.

1.04 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. PRODUCT DATA: PROVIDE COMPONENT DIMENSIONS, DESCRIBE

COMPONENTS WITHIN ASSEMBLY, ANCHORAGE AND FASTENERS,

GLASS AND INFILL, DOOR HARDWARE, INTERNAL DRAINAGE DETAILS.

C. SHOP DRAWINGS: INDICATE SYSTEM DIMENSIONS, FRAMED

OPENING REQUIREMENTS AND TOLERANCES, AFFECTED RELATED

WORK, EXPANSION AND CONTRACTION JOINT LOCATION AND

DETAILS, AND FIELD WELDING REQUIRED.

D. WARRANTY: SUBMIT MANUFACTURER WARRANTY AND ENSURE

FORMS HAVE BEEN COMPLETED IN DEVELOPERS DIVERSIFIED'S

NAME AND REGISTERED WITH MANUFACTURER.

1.05 DELIVERY, STORAGE, AND PROTECTION

A. HANDLE PRODUCTS OF THIS SECTION IN ACCORDANCE WITH AAMA

CW-10.

B. PROTECT FINISHED ALUMINUM SURFACES WITH WRAPPING. DO NOT

USE ADHESIVE PAPERS OR SPRAYED COATINGS WHICH BOND TO

ALUMINUM WHEN EXPOSED TO SUNLIGHT OR WEATHER.

1.06 PROJECT CONDITIONS

A. COORDINATE THE WORK WITH INSTALLATION OF FIRESTOPPING

COMPONENTS OR MATERIALS.

1.07 WARRANTY

A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL

WARRANTY REQUIREMENTS.

B. PROVIDE FIVE YEAR MANUFACTURER WARRANTY AGAINST FAILURE

OF GLASS SEAL ON INSULATING GLASS UNITS, INCLUDING

INTERPANE DUSTING OR MISTING. INCLUDE PROVISION FOR

REPLACEMENT OF FAILED UNITS.

C. PROVIDE FIVE YEAR MANUFACTURER WARRANTY AGAINST

EXCESSIVE DEGRADATION OF EXTERIOR FINISH. INCLUDE

PROVISION FOR REPLACEMENT OF UNITS WITH EXCESSIVE FADING,

CHALKING, OR FLAKING.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. ACCEPTABLE MANUFACTURERS - STOREFRONT SYSTEM:

1. KAWNEER COMPANY, INC, PRODUCT TRI-FAB VG- 451T AT

EXTERIOR AND TRI-FAB 450 FOR INTERIOR APPLICATIONS:

WWW.KAWNEER.COM.

2. UNITED STATES ALUMINUM CORP: WWW.USALUM.COM.

3. VISTAWALL ARCHITECTURAL PRODUCTS:

WWW.VISTAWALL.COM.

4. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT

REQUIREMENTS.

B. ACCEPTABLE MANUFACTURERS - AUTOMATIC DOORS

1. DOORS SHALL BE BESAM UNISLIDE OC3-8 AUTOMATIC

SLIDING DOOR PACKAGE AS INDICATED ON DRAWINGS.

INSTALLTION BY BESAM CERTIFIED INSTALLER PER BESAM

SPECIFICATIONS.

2.02 COMPONENTS

A. ALUMINUM-FRAMED STOREFRONT: FACTORY FABRICATED,

FACTORY FINISHED ALUMINUM FRAMING MEMBERS WITH INFILL, AND

RELATED FLASHINGS, ANCHORAGE AND ATTACHMENT DEVICES.

1. FINISH: CLASS I COLOR ANODIZED AT INTERIOR, OR TO

MATCH EXISTING FINISH AS INDICATED ON DRAWINGS.

2.03 MATERIALS

A. EXTRUDED ALUMINUM: ASTM B 221 (ASTM B 221M).

B. FASTENERS: STAINLESS STEEL.

C. EXPOSED FLASHINGS: 0.032 INCH (0.8 MM) THICK ALUMINUM SHEET,

FINISH TO MATCH FRAMING MEMBERS.

D. CONCEALED FLASHINGS: 0.018 INCH (0.5 MM) THICK GALVANIZED

STEEL.

E. PERIMETER SEALANT: TYPE SPECIFIED IN SECTION 079200.

F. GLASS: AS SPECIFIED IN SECTION 088000.

1. GLASS IN EXTERIOR FRAMING: TYPE INSULATED UNITS.

2.04 FINISHES

A. COMPLY WITH AA DAF-45 FOR ALUMINUM FINISHES REQUIRED.

B. CLASS I COLOR ANODIZED FINISH: ANODIC COATING TO MATCH

EXISTING, NOT LESS THAN 0.7 MILS (0.018 MM) THICK.

C. TOUCH-UP MATERIALS: AS RECOMMENDED BY COATING

MANUFACTURER FOR FIELD APPLICATION.

2.05 HARDWARE

2.06 FABRICATION

A. FABRICATE COMPONENTS WITH MINIMUM CLEARANCES AND SHIM

SPACING AROUND PERIMETER OF ASSEMBLY, YET ENABLING

INSTALLATION AND DYNAMIC MOVEMENT OF PERIMETER SEAL.

B. ACCURATELY FIT AND SECURE JOINTS AND CORNERS. MAKE JOINTS

FLUSH, HAIRLINE, AND WEATHERPROOF.

C. PREPARE COMPONENTS TO RECEIVE ANCHOR DEVICES. FABRICATE

ANCHORS.

D. COAT CONCEALED METAL SURFACES THAT WILL BE IN CONTACT

WITH CEMENTITIOUS MATERIALS OR DISSIMILAR METALS WITH

BITUMINOUS PAINT.

E. ARRANGE FASTENERS AND ATTACHMENTS TO CONCEAL FROM VIEW.

F. REINFORCE FRAMING MEMBERS FOR IMPOSED LOADS.

G. FINISHING: APPLY FACTORY FINISH TO ALL SURFACES THAT WILL BE

EXPOSED IN COMPLETED ASSEMBLIES.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY DIMENSIONS, TOLERANCES, AND METHOD OF ATTACHMENT

WITH OTHER WORK.

B. VERIFY THAT WALL OPENINGS AND ADJOINING AIR AND VAPOR SEAL

MATERIALS ARE READY TO RECEIVE WORK OF THIS SECTION.

3.02 INSTALLATION

A. INSTALL WALL SYSTEM IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

B. ATTACH TO STRUCTURE TO PERMIT SUFFICIENT ADJUSTMENT TO

ACCOMMODATE CONSTRUCTION TOLERANCES AND OTHER

IRREGULARITIES.

C. PROVIDE ALIGNMENT ATTACHMENTS AND SHIMS TO PERMANENTLY

FASTEN SYSTEM TO BUILDING STRUCTURE.

D. ALIGN ASSEMBLY PLUMB AND LEVEL, FREE OF WARP OR TWIST.

MAINTAIN ASSEMBLY DIMENSIONAL TOLERANCES, ALIGNING WITH

ADJACENT WORK.

E. PROVIDE THERMAL ISOLATION WHERE COMPONENTS PENETRATE

OR DISRUPT BUILDING INSULATION.

F. INSTALL SILL FLASHINGS. TURN UP ENDS AND EDGES, SEAL TO

ADJACENT WORK TO FORM WATER TIGHT DAM.

G. COORDINATE ATTACHMENT AND SEAL OF PERIMETER AIR AND

VAPOR BARRIER MATERIALS.

H. PACK FIBROUS INSULATION IN SHIM SPACES AT PERIMETER OF

ASSEMBLY TO MAINTAIN CONTINUITY OF THERMAL BARRIER.

I. INSTALL HARDWARE USING TEMPLATES PROVIDED.

J. INSTALL GLASS IN ACCORDANCE WITH SECTION 088000, USING

GLAZING METHOD REQUIRED TO ACHIEVE PERFORMANCE CRITERIA.

K. INSTALL PERIMETER SEALANT IN ACCORDANCE WITH SECTION

079200.

3.03 ERECTION TOLERANCES

A. MAXIMUM VARIATION FROM PLUMB: 0.06 INCHES EVERY 3 FT (1.5

MM/M) NON-CUMULATIVE OR 1/16 INCHES PER 10 FT (1.5 MM/3 M),

WHICHEVER IS LESS.

B. MAXIMUM MISALIGNMENT OF TWO ADJOINING MEMBERS ABUTTING

IN PLANE: 1/32 INCH (0.8 MM).

3.04 ADJUSTING

A. ADJUST OPERATING HARDWARE FOR SMOOTH OPERATION.

3.05 CLEANING AND PROTECTION

A. REMOVE PROTECTIVE MATERIAL FROM PRE-FINISHED ALUMINUM

SURFACES.

B. WASH DOWN SURFACES WITH A SOLUTION OF MILD DETERGENT IN

WARM WATER, APPLIED WITH SOFT, CLEAN WIPING CLOTHS. TAKE

CARE TO REMOVE DIRT FROM CORNERS. WIPE SURFACES CLEAN.

C. REMOVE EXCESS SEALANT BY METHOD ACCEPTABLE TO SEALANT

MANUFACTURER.

D. TOUCH-UP MINOR DAMAGE TO FACTORY APPLIED FINISH, REPLACE

COMPONENTS THAT CANNOT BE SATISFACTORILY REPAIRED.

E. PROTECT FINISHED WORK FROM DAMAGE.

END OF SECTION

SECTION 084229 - AUTOMATIC ENTRANCES

PART 1

1.01 SECTION INCLUDES

A. SLIDING AUTOMATIC ENTRANCES

1.02 RELATED SECTIONS

A. DIVISION 7 FOR CAULKING

B. DIVISION 8 FOR DOOR HARDWARE

C. DIVISION 26 FOR ELECTRICAL CONNECTIONS

1.03 REFERENCES

A. UL 325 - STANDARD FOR DOOR, DRAPERY, GATE,LlOUVER, AND

WINDOW OPERATORS AND SYSTEMS

B. ANSI/BMHA A156.10: STANDARD FOR POWER OPERATED PEDESTRIAN

DOORS

C. ANSI/BMHA A156.5: STANDARD FOR AUXILIARY LOCKS AND

ASSOCIATED PRODUCTS

D. ANSI Z97.1: STANDARDS FOR SAFETY GLAZING MATERIALS USED IN

BUILDINGS - SAFETY PERFORMANCE SPECIFICATIONS AND METHODS

E. CPSC 16 CFR 1201: SAFETY STANDARD FOR ARCHITECTURAL

GLAZING MATERIALS

F. ASTM B221 - STANDARD SPECIFICATION FOR ALUMINUM EXTRUDED

BARS, RODS, WIRE, PROFILES, AND TUBES

G. ASTM B209 - STANDARD SPECIFICATION FOR ALUMINUM SHEET AND

PLATE

H. AAMA 611 - VOLUNTARY SPECIFICATION FOR ANODIZED

ARCHITECTURAL ALUMINUM, AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION, 1998

I. AAMA 701 - VOLUNTARY SPECIFICATION FOR PILE

WEATHERSTRIPPING AND REPLACEABLE FENESTRATION

WEATHERSEALS

1.04 SUBMITTALS

A. SHOP DRAWINGS: INCLUDE PLANS, ELEVATIONS, SECTIONS,

DETAILS, HARDWARE MOUNTING HEIGHTS, AND ATTACHMENTS TO

OTHER WORK.

B. COLOR SAMPLES FOR SELECTION OF FCATORY-APPLIED COLOR

FINISHES.

C. CLOSEOUT SUBMITTALS: OWNER'S MANUAL AND WARRANTIES

1.05 WARRANTY

A. AUTOMATIC ENTRANCES SHALL BE FREE OF DEFECTS IN MATERIAL

AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF

SUBSTANTIAL COMPLETION.

PART 2 PRODUCTS

2.01 AUTOMATIC ENTRANCES

A. MANUFACTURER: RECORD AUTOMATIC DOOR SYSTEMS

(RECORD-USA): SERIES 5100. SIZE: AS INDICATED ON DRAWINGS.

BI-PART DOOR PACKAGE

B. SUBSTITUTIONS: SEE DIVISION 1 FOR SUBSTITUTION PROCEDURES

2.02 MATERIALS

A. ALUMINUM

A.A. HEADERS, STILES, RAILS AND FRAMES: 6063-T6

A.B. EXTRUDED BARS, RODS, PROFILES AND TUBES: ASTM B 221

A.C. SHEET AND PLATE: ASTM B 209

B. SEALANTS AND JOINT FILLERS: SEE DIVISION 7 SECTION JOINT

SEALANTS

2.03 COMPONENTS

A. FRAMING AND TENSION MEMBERS: NOMINAL SIZE 1 3/4" X 4 1/2" WITH

CONCEALED FASTENERS. TRANSOM SHALL BE INTEGRAL TO SLIDING

DOOR FRAMING SYSTEM WITH FLUSH GLAZING.

B. STILE AND RAIL DOORS AND SIDELIGHTS: 1 3/4" THICK GLAZED

DOORS WITH EXTRUDED ALUMINUM TUBULAR STILE AND RAIL

MEMBERS. SNAP ON GLAZING STOPS AND GASKETS. 2" NOMINAL

WIDTH NARROW STILE. MINIMUM 10" NOMINAL HEIGHT ON BOTTOM

RAIL DESIGN. HORIZONTAL TUBULAR RAIL MEMBER FOR EACH DOOR,

2" NOMINAL WIDTH

C. GLAZING: 1" CLEAR IG ON EXTERIOR DOOR PACKAGE, 1/4" CLEAR

TEMP ON INTERIOR DOOR PACKAGE.

D. HEADERS: CONCEALED MOUNTING WITH ONE SIDE OF HEADER

FLUSH WITH FRAMING. CAPABLE OF SUPPORTING UP TO 220 LBS PER

PANEL, UP TO 4 PANELS, OVER SPANS OF 14 FEET WITHOUT

INTERMEDIATE SUPPORTS

E. CARRIER ASSEMBLIES AND OVERHEAD ROLLER TRACKS:

MANUFACTURER'S STANDARD CARRIER PACKAGE

F. THRESHOLDS: CONTINUOUS STANDARD TAPERED EXTRUSION

DOUBLE BEVEL

G. FASTENERS: STANDARD CORROSION RESISTANT, NON-STAINING,

NON-BLEEDING

2.04 ELECTRICAL CONTROLS

A. MICROPROCESSOR CONTROLLER AND POSITION ENCODER WITH

SAFETY LOGIC AND WATCHDOG LED

2.05 ACTIVATION AND SAFETY DEVICES

A. DUAL ACTIVATION STANLEY SU-100 MOTION SENSOR SHALL BE

MOUNTED ON EACH SIDE OF THE DOOR HEADER

B. STAN GUARD THRESHOLD SAFETY SENSORS SHALL BE PROVIDED

C. PHOTO-ELECTRONIC BEAMS SHALL BE PULSED INFRARED TYPE

2.06 HARDWARE

A. EMERGENCY BREAKAWAY RELEASE SHALL ALLOW BOTH PANELS TO

SWING OUT 90 DEGREES

B. DEADLOCKS: 2-POINT LOCKING, KEY EXTERIOR, THUMB TURN

INTERIOR

C. CONTROL SWITCH: ROTARY SWITCH MOUNTED ON THE INTERIOR

JAMB

2.07 ALUMINUM FINISH

D. TO MATCH EXISTING STOREFRONT FINISH

PART 3 EXECUTION

3.01 INSPECTION

A. EXAMINE EXISTING CONDITIONS FOR COMPLIANCE WITH

REQUIREMENTS FOR INSTALLATION TOLERANCES, HEADER

SUPPORT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF

AUTOMATIC ENTRANCES.

3.02 INSTALLATION

A. DO NOT INSTALL DAMAGED COMPONENTS

B. INSTALL ENTRANCES PLUMB AND TRUE IN ALIGNMENT. ANCHOR

SECURELY IN PLACE.

C. DOOR OPERATORS: CONNECT DOOR OPERATORS TO ELECTRICAL

POWER DISTRIBUTION SYSTEM

D. GLAZING: PER MANUFACTURER'S INSTRUCTIONS

E. SEALANTS: PER DIVISION 7 SECTION JOINT SEALANTS

3.03 FIELD QUALITY CONTROL

A. TESTING SERVICES: FACTORY TRAINED INSTALLER SHALL TEST AND

INSPECT EACH DOOR FOR FULL COMPLIANCE.

3.04 ADJUSTING

A. ADJUST DOOR OPERATORS, CONTROLS, AND HARDWARE FOR

SMOOTH AND SAFE OPERATION.

3.05 CLEANING AND PROTECTION

A. CLEAN GLASS AND ALUMINUM SURFACES PROMPTLY AFTER

INSTALLATION.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.4

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.4

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 11: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 085113 - ALUMINUM WINDOWS

1.01 QUALITY ASSURANCE

A. MOCKUPS FOR EACH FORM OF CONSTRUCTION.

1.02 WARRANTY

A. WINDOWS: 10 YEARS FROM DATE OF SUBSTANTIAL COMPLETION.

B. GLAZING UNITS: 10 YEARS FROM DATE OF SUBSTANTIAL COMPLETION.

C. ALUMINUM FINISH: 10 YEARS FROM DATE OF SUBSTANTIAL

COMPLETION.

1.03 WINDOW PERFORMANCE REQUIREMENTS

A. PRODUCT STANDARD: AAMA/WDMA/CSA 101/I.S.2/A440.

B. CONDENSATION-RESISTANCE FACTOR: 52 COMPLYING WITH

AAMA 1503.

C. SOUND TRANSMISSION CLASS: 26 MINIMUM.

1.04 ALUMINUM WINDOWS

A. FRAMES AND SASHES: NONTHERMAL ALUMINUM EXTRUSIONS.

B. GLAZING:

1. GLASS: CLEAR

C. GLAZING SYSTEM: MANUFACTURER'S STANDARD

D. ACCESSORIES: INTEGRAL VENTILATING SYSTEM/DEVICE

E. ALUMINUM FINISH: TO MATCH EXISTING STOREFRONT].

1.05 FIELD QUALITY CONTROL

A. TESTING: BY CONTRACTOR-ENGAGED AGENCY.

END OF SECTION

SECTION 087100 - DOOR HARDWARE

PART 1 GENERAL

1.01 SECTION INCLUDES

A. HARDWARE FOR HOLLOW STEEL AND WOOD DOORS.

B. LOCK CYLINDERS FOR DOORS FOR WHICH HARDWARE IS SPECIFIED IN

OTHER SECTIONS.

C. THRESHOLDS.

D. WEATHERSTRIPPING, SEALS AND DOOR GASKETS.

1.02 REFERENCES

A. DHI (LOCS) - RECOMMENDED LOCATIONS FOR ARCHITECTURAL

HARDWARE FOR STANDARD STEEL DOORS AND FRAMES, DOOR AND

HARDWARE INSTITUTE, 2001.

B. NFPA 101 - CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND

STRUCTURES, NATIONAL FIRE PROTECTION ASSOCIATION, 2000.

1.03 QUALITY ASSURANCE

1.04 DELIVERY, STORAGE, AND PROTECTION

A. PACKAGE HARDWARE ITEMS INDIVIDUALLY, LABEL AND IDENTIFY

EACH PACKAGE WITH DOOR OPENING CODE TO MATCH HARDWARE

SCHEDULE.

1.05 COORDINATION

A. COORDINATE THE WORK WITH OTHER DIRECTLY AFFECTED SECTIONS

INVOLVING MANUFACTURE OR FABRICATION OF INTERNAL

REINFORCEMENT FOR DOOR HARDWARE.

B. FURNISH TEMPLATES FOR DOOR AND FRAME PREPARATION.

C. SEQUENCE INSTALLATION TO ENSURE UTILITY CONNECTIONS ARE

ACHIEVED IN AN ORDERLY AND EXPEDITIOUS MANNER.

D. COORDINATE THE OWNER'S KEYING REQUIREMENTS DURING THE

COURSE OF THE WORK.

1.06 WARRANTY

A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL

WARRANTY REQUIREMENTS.

1.07 MAINTENANCE PRODUCTS

A. PROVIDE SPECIAL WRENCHES AND TOOLS APPLICABLE TO EACH

DIFFERENT OR SPECIAL HARDWARE COMPONENT.

B. PROVIDE MAINTENANCE TOOLS AND ACCESSORIES SUPPLIED BY

HARDWARE COMPONENT MANUFACTURER.

PART 2 PRODUCTS

2.01 REFER TO DRAWINGS FOR SCHEDULES AND SPECIFICATIONS.

2.02 GENERAL REQUIREMENTS FOR DOOR HARDWARE PRODUCTS

A. PROVIDE PRODUCTS THAT COMPLY WITH THE FOLLOWING:

1. APPLICABLE PROVISIONS OF FEDERAL, STATE, AND LOCAL

CODES.

2. APPLICABLE PROVISIONS OF NFPA 101, LIFE SAFETY CODE.

B. FINISHES: IDENTIFIED IN SCHEDULE.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT DOORS AND FRAMES ARE READY TO RECEIVE WORK

AND DIMENSIONS ARE AS INSTRUCTED BY THE MANUFACTURER.

3.02 INSTALLATION

A. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS AND APPLICABLE CODES.

B. USE TEMPLATES PROVIDED BY HARDWARE ITEM MANUFACTURER.

C. MOUNTING HEIGHTS FOR HARDWARE FROM FINISHED FLOOR TO

CENTER LINE OF HARDWARE ITEM:

1. FOR STEEL DOORS AND FRAMES: COMPLY WITH DHI

"RECOMMENDED LOCATIONS FOR ARCHITECTURAL HARDWARE

FOR STEEL DOORS AND FRAMES."

3.03 ADJUSTING

A. ADJUST WORK UNDER PROVISIONS OF SECTION 017700.

B. ADJUST HARDWARE FOR SMOOTH OPERATION.

3.04 PROTECTION OF FINISHED WORK

A. PROTECT FINISHED WORK UNDER PROVISIONS OF SECTION 017700.

B. DO NOT PERMIT ADJACENT WORK TO DAMAGE HARDWARE OR FINISH.

END OF SECTION

SECTION 088000 - GLAZING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. GLASS AND PLASTIC GLAZING.

B. GLAZING COMPOUNDS AND ACCESSORIES.

C. MONOLITHIC CERAMIC ENAMEL FRIT SPANDREL GLASS, CERAMIC

ENAMEL FRIT SPANDREL GLASS IN INSULATING GLASS (IG) UNITS

1.02 RELATED SECTIONS

A. SECTION 079200 - JOINT SEALERS: SEALANT AND BACK-UP MATERIAL.

B. SECTION 081113 - HOLLOW METAL DOORS AND FRAMES: GLAZED

DOORS AND BORROWED LITES.

C. SECTION 084113 - ALUMINUM-FRAMED STOREFRONTS.

1.03 REFERENCES

A. ANSI Z97.1 - AMERICAN NATIONAL STANDARD FOR SAFETY GLAZING

MATERIALS USED IN BUILDINGS, SAFETY PERFORMANCE

SPECIFICATIONS AND METHODS OF TEST, 1984 (R1994).

B. ASTM C162 - STANDARD TERMINOLOGY OF GLASS AND GLASS

PRODUCTS.

C. ASTM C 1036 - STANDARD SPECIFICATION FOR FLAT GLASS, 2001.

D. ASTM C1048 - STANDARD SPECIFICATION FOR HEAT-TREATED FLAT

GLASS -- KIND HS, KIND FT COATED AND UNCOATED GLASS.

E. ASTM C 1193 - STANDARD GUIDE FOR USE OF JOINT SEALANTS, 2000.

F. ASTM E2188 - STANDARD TEST METHOD FOR INSULATING GLASS UNIT

PERFORMANCE.

G. ASTM E2189 - STANDARD TEST METHOD FOR TESTING RESISTANCE TO

FOGGING IN INSULATING GLASS UNITS.

H. ASTM E2190 - STANDARD SPECIFICATION FOR INSULATING GLASS UNIT

PERFORMANCE AND EVALUATION.

I. ASTM E1300 - STANDARD PRACTICE FOR DETERMINING THE MINIMUM

THICKNESS AND TYPE OF GLASS REQUIRED TO RESIST A SPECIFIED

LOAD.

J. ASTM E2188 - STANDARD TEST METHOD FOR INSULATING GLASS UNIT

PERFORMANCE.

K. ASTM E2189 - STANDARD TEST METHOD FOR TESTING RESISTANCE TO

FOGGING IN INSULATING GLASS UNITS.

L. ASTM E2190 - STANDARD SPECIFICATION FOR INSULATING GLASS UNIT

PERFORMANCE AND EVALUATION.

M. GANA (GM) - GANA GLAZING MANUAL, GLASS ASSOCIATION OF NORTH

AMERICA, 1997.

N. GANA (SM) - FGMA SEALANT MANUAL, GLASS ASSOCIATION OF NORTH

AMERICA, 1990.

1.04 QUALITY ASSURANCE

A. PERFORM WORK IN ACCORDANCE WITH GANA GLAZING MANUAL AND

FGMA SEALANT MANUAL FOR GLAZING INSTALLATION METHODS.

B. INSTALLER QUALIFICATIONS: COMPANY SPECIALIZING IN

PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS

DOCUMENTED EXPERIENCE.

C. SAFETY GLASS PRODUCTS IN THE US ARE TO COMPLY WITH CPSC 16

CFR PART 1201 FOR CATEGORY II MATERIALS.

D. INSULATING GLASS PRODUCTS ARE TO BE PERMANENTLY MARKED

EITHER ON SPACERS OR AT LEAST ONE INSULATING UNIT

COMPONENT WITH APPROPRIATE CERTIFICATION LABEL OF

INSPECTING AND TESTING AGENCY INDICATED BELOW:

1. US - INSULATING GLASS CERTIFICATION COUNCIL (IGCC)

1.05 ENVIRONMENTAL REQUIREMENTS

A. DO NOT INSTALL GLAZING WHEN AMBIENT TEMPERATURE IS LESS

THAN 50 DEGREES F (10 DEGREES C).

B. MAINTAIN MINIMUM AMBIENT TEMPERATURE BEFORE, DURING AND 24

HOURS AFTER INSTALLATION OF GLAZING COMPOUNDS.

1.06 WARRANTY

A. SEE SECTION 017700 - CLOSEOUT SUBMITTALS, FOR ADDITIONAL

WARRANTY REQUIREMENTS.

B. PROVIDE A FIVE (5) YEAR WARRANTY TO INCLUDE COVERAGE FOR

SEALED GLASS UNITS FROM SEAL FAILURE, INTERPANE DUSTING OR

MISTING, AND REPLACEMENT OF SAME.

PART 2 PRODUCTS

2.01 FLAT GLASS MATERIALS

A. MANUFACTURERS:

1. AFG INDUSTRIES, INC: WWW.AFGGLASS.COM.

2. GUARDIAN INDUSTRIES CORPORATION: WWW.GUARDIAN.COM.

3. PPG INDUSTRIES, INC: WWW.PPG.COM.

4. OLDCASTLE BUILDINGENVELOPE®

5. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT

REQUIREMENTS.

B. CLEAR FLOAT GLASS: CLEAR, HEAT STRENGTHENED.

1. COMPLY WITH ASTM C 1048, TYPE I, TRANSPARENT FLAT,

CLASS 1 CLEAR, QUALITY Q3 (GLAZING SELECT).

C. SAFETY GLASS: CLEAR, FULLY TEMPERED WITH HORIZONTAL

TEMPERING.

1. COMPLY WITH ANSI Z97.1.

2.02 SEALED INSULATING GLASS MATERIALS

A. MANUFACTURERS:

1. GUARDIAN INDUSTRIES CORPORATION: WWW.GUARDIAN.COM.

2. PPG INDUSTRIES, INC. WWW.PPGGLAZING.COM

3. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT

REQUIREMENTS.

B. INSULATED GLASS UNITS: DOUBLE PANE WITH GLASS TO ELASTOMER

EDGE SEAL.

1. OUTER PANE OF FLOAT GLASS, INNER PANE OF FLOAT GLASS.

2. TOTAL UNIT THICKNESS OF 1 INCH.

3. PROVIDE SAFETY GLASS AS INDICATED.

C. EDGE SEAL CONSTRUCTION: ALUMINUM, BENT AND SOLDERED

CORNERS.

D. EDGE SEAL MATERIAL: BLACK COLOR.

2.03 SEALED INSULATING GLASS (IG) UNITS WITH CERAMIC ENAMEL FRIT

SPANDREL INBOARD LITE

1. INSULATING GLASS UNIT MAKEUP

2. GLASS TINT: TO BE SELECTED

3. NOMINAL THICKNESS: TO MATCH EXISTING

2.04 GLAZING ACCESSORIES

A. PRODUCTS IN COMPLIANCE WITH ASTM C920 AND REFERENCED

GLAZING STANDARDS, THE REQUIREMENTS OF THE GLASS AND

STOREFRONT MANUFACTURERS AND PROVEN TRACK RECORD TO BE

COMPATABLE WITH ONE ANOTHER AND WITH THE MATERIALS THEY

WILL COME IN CONTACT WITH.

1. COMPRESSION GASKETS: AS REQUIRED FOR SPECIFED

ALUMINIUM STOREFRONT AND DOOR SYSTEMS.

2. SUBSTITUTIONS: REFER TO SECTION 016000 - PRODUCT

REQUIREMENTS.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND

WITHIN TOLERANCE.

B. VERIFY THAT SURFACES OF GLAZING CHANNELS OR RECESSES ARE

CLEAN, FREE OF OBSTRUCTIONS THAT MAY IMPEDE MOISTURE

MOVEMENT, WEEPS ARE CLEAR, AND READY TO RECEIVE GLAZING.

3.02 PREPARATION

A. CLEAN CONTACT SURFACES WITH SOLVENT AND WIPE DRY.

B. SEAL POROUS GLAZING CHANNELS OR RECESSES WITH SUBSTRATE

COMPATIBLE PRIMER OR SEALER.

C. PRIME SURFACES SCHEDULED TO RECEIVE SEALANT.

D. INSTALL SEALANTS IN ACCORDANCE WITH ASTM C 1193 AND FGMA

SEALANT MANUAL.

E. INSTALL SEALANT IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

F. PROTECT GLASS EDGES DURING HANDLING AND INSTALLATION.

G. DO NOTEXCEED EDGE PRESSURES SPECIFIED BY GLASS

MANUFACTURER FOR INSTALLING GLASS LITES.

H. SET GLASS LITES IN SERIES WITH UNIFORM DRAW, BOW AND SIMILAR

CHARACTERISTICS.

I. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR

GLASS, SEALANTS, GASKETS AND OTHER GLAZING MATERIALS.

3.03 CLEANING

A. REMOVE GLAZING MATERIALS FROM FINISH SURFACES.

B. REMOVE LABELS AFTER WORK IS COMPLETE.

C. CLEAN GLASS AND ADJACENT SURFACES.

3.04 PROTECTION OF FINISHED WORK

A. AFTER INSTALLATION, MARK PANE WITH AN 'X' BY USING REMOVABLE

PLASTIC TAPE OR PASTE.

END OF SECTION

SECTION 088720 - ARCHITECTURAL WINDOW FILM

PART 1 GENERAL

1.01 SECTION INCLUDES

A. INTERIOR WINDOW FILM

B. DECORATIVE WINDOW FILM.

C. PRIVACY WINDOW FILM.

1.02 PERFORMANCE REQUIREMENTS

A. FIRE PERFORMANCE: SURFACE BURNING CHARACTERISTICS WHEN

TESTED IN ACCORDANCE WITH ASTM E 84:

1. FLAME SPREAD: 25, MAXIMUM

2. SMOKE DEVELOPED: 450, MAXIMUM.

1.05 PROJECT CONDITIONS

A. MAINTAIN ENVIRONMENTAL CONDITIONS (TEMPERATURE, HUMIDITY,

AND VENTILATION) WITHIN LIMITS RECOMMENDED BY MANUFACTURER

FOR OPTIMUM RESULTS. DO NOT INSTALL PRODUCTS UNDER

ENVIRONMENTAL CONDITIONS OUTSIDE MANUFACTURER'S ABSOLUTE

LIMITS.

PART 2 PRODUCTS

2.01 WINDOW FILM

A. MANUFACTURERS:

1. 3M

2. HANITA TEK WINDOW FILMS

B. COLOR: TO BE SELECTED BY ARCHITECT, APPROVED BY PSP.

PART 3 EXECUTION

3.01 EXAMINATION

A. DO NOT BEGIN INSULATION UNTIL SUBSTRATES HAVE BEEN

PROPERLY PREPARED.

3.02 PREPARATION

A. CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION.

B. PREPARE SURFACES USING THE METHODS RECOMMENDED BY THE

MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE

SUBSTRATE UNDER THE PROJECT CONDITIONS.

3.04 INSULATION

A. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

B. CUT FILM EDGES NEATLY AND SQUARE AT A UNIFORM DISTANCE OF

1/8 INCH (3 MM) TO 1/16 INCH (1.5 MM) OF WINDOW SEALANT. USE NEW

BLADE TIPS AFTER 3 TO 4 CUTS.

C. SPRAY THE SLIP SOLUTION, COMPOSED OF ONE CAPFUL OF BABY

SHAMPOO OR DISHWASHING LIQUID TO 1 GALLON OF WATER, ON

WINDOW GLASS AND ADHESIVE TO FACILITATE PROPER POSITIONING

OF FILM.

D. APPLY FILM TO GLASS AND LIGHTLY SPRAY FILM WITH SLIP SOLUTION.

E. SQUEEGEE FROM TOP TO BOTTOM OF WINDOW. SPRAY SLIP

SOLUTION TO FILM AND SQUEEGEE A SECOND TIME.

F. BUMP FILM EDGE WITH LINT-FREE TOWEL WRAPPED AROUND EDGE

OF A 5-WAY TOOL.

G. UPON COMPLETION OF FILM APPLICATION, ALLOW 30 DAYS FOR

MOISTURE FROM FILM INSTALLATION TO DRY THOROUGHLY, AND TO

ALLOW FILM TO DRY FLAT WITH NO MOISTURE DIMPLES WHEN

VIEWED UNDER NORMAL VIEWING CONDITIONS

3.05 CLEAN AND PROTECTION

A. REMOVE LEFT OVER MATERIAL AND DEBRIS FROM WORK AREA. USE

NECESSARY MEANS TO PROTECT FILM BEFORE, DURING, AND AFTER

INSTALLATION.

B. TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE

SUBSTANTIAL COMPLETION.

C. AFTER APPLICATION OF FILM, WASH FILM USING COMMON WINDOW

CLEANING SOLUTIONS, INCLUDING AMMONIA SOLUTIONS, 30 DAYS

AFTER APPLICATION. DO NOT USE ABRASIVE TYPE CLEANING AGENTS

AND BRISTLE BRUSHES TO AVOID SCRATCHING FILM. USE SYNTHETIC

SPONGES OR SOFT CLOTHS.

END OF SECTION

SECTION 092900 - GYPSUM BOARD ASSEMBLIES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. METAL STUD WALL FRAMING.

B. METAL CHANNEL CEILING FRAMING.

C. ACOUSTIC INSULATION.

D. GYPSUM SHEATHING.

E. GYPSUM WALLBOARD.

F. JOINT TREATMENT AND ACCESSORIES.

1.02 REFERENCES

A. ASTM C 36/C 36M - STANDARD SPECIFICATION FOR GYPSUM

WALLBOARD, 2001.

B. ASTM C 79/C 79M - STANDARD SPECIFICATION FOR TREATED CORE

AND NONTREATED CORE GYPSUM SHEATHING BOARD, 2001.

C. ASTM C 475/C 475M - STANDARD SPECIFICATION FOR JOINT

COMPOUND AND JOINT TAPE FOR FINISHING GYPSUM BOARD, 2002.

D. ASTM C 630/C 630M - STANDARD SPECIFICATION FOR

WATER-RESISTANT GYPSUM BACKING BOARD, 2000.

E. ASTM C 645 - STANDARD SPECIFICATION FOR NONSTRUCTURAL STEEL

FRAMING MEMBERS, 2000.

F. ASTM C 665 - STANDARD SPECIFICATION FOR MINERAL-FIBER

BLANKET THERMAL INSULATION FOR LIGHT FRAME CONSTRUCTION

AND MANUFACTURED HOUSING, 2001.

G. ASTM C 754 - STANDARD SPECIFICATION FOR INSTALLATION OF STEEL

FRAMING MEMBERS TO RECEIVE SCREW-ATTACHED GYPSUM PANEL

PRODUCTS, 2000.

H. ASTM C 840 - STANDARD SPECIFICATION FOR APPLICATION AND

FINISHING OF GYPSUM BOARD, 2002.

I. ASTM C 1002 - STANDARD SPECIFICATION FOR STEEL SELF-PIERCING

TAPPING SCREWS FOR THE APPLICATION OF GYPSUM PANEL

PRODUCTS OR METAL PLASTER BASES TO WOOD STUDS OR STEEL

STUDS, 2001.

1.03 QUALITY ASSURANCE

A. PERFORM IN ACCORDANCE WITH ASTM C 840.

PART 2 PRODUCTS

2.01 METAL FRAMING MATERIALS

A. NON-LOADBEARING FRAMING SYSTEM COMPONENTS: ASTM C 645,

GALVANIZED SHEET STEEL, OF SIZE AND PROPERTIES NECESSARY TO

COMPLY WITH ASTM C 754 FOR THE SPACING INDICATED, WITH

MAXIMUM DEFLECTION OF WALL FRAMING OF L/240 AT 5 PSF (240 PA).

1. STUDS: C SHAPED WITH KNURLED FACES.

2. RUNNERS: U SHAPED, SIZED TO MATCH STUDS.

3. CEILING CHANNELS: C SHAPED.

B. CEILING HANGERS: TYPE AND SIZE AS SPECIFIED IN ASTM C 754 FOR

SPACING REQUIRED.

C. PARTITION HEAD TO STRUCTURE CONNECTIONS: PROVIDE TRACK

FASTENED TO STRUCTURE WITH LEGS OF SUFFICIENT LENGTH TO

ACCOMMODATE DEFLECTION, FOR FRICTION FIT OF STUDS CUT

SHORT AND FASTENED AS INDICATED ON DRAWINGS.

D. BOTTOM AND TOP TRACK OF CURVED CURTAIN WALL TO BE

CONSTRUCTED WITH 3 5/8" 'FLEXTRACK' OR EQUAL. SOURCE: FIVE

STAR SUPPLY (216) 595-9525

2.02 GYPSUM BOARD MATERIALS

A. GYPSUM WALLBOARD: ASTM C 36/C 36M AND ASTM C 1396/C 1396M.

SIZES TO MINIMIZE JOINTS IN PLACE, ENDS SQUARE CUT.

1. EDGES: TAPERED.

B. WATER-RESISTANT GYPSUM BACKING BOARD: ASTM C 630/C 630M

AND ASTM C 1396/C 1396M, ENDS SQUARE CUT.

C. EXTERIOR GYPSUM SHEATHING BOARD: GYPSUM SHEATHING

MANUFACTURED IN ACCORDANCE WITH ASTM C 1177 WITH GLASS

MATS BOTH SIDES AND LONG EDGES, WATER-RESISTANT TREATED

CORE..

1. EDGES: SQUARE, FOR VERTICAL APPLICATION.

2.03 ACCESSORIES

A. ACOUSTIC INSULATION: ASTM C 665, PREFORMED GLASS FIBER,

FRICTION FIT TYPE, UNFACED.

B. JOINT MATERIALS: ASTM C 475 AND AS RECOMMENDED BY GYPSUM

BOARD MANUFACTURER FOR PROJECT CONDITIONS.

1. POWDER-TYPE VINYL-BASED JOINT COMPOUND.

C. SCREWS: ASTM C 1002, SELF-PIERCING TAPPING TYPE.

D. STAPLES: ASTM C 840.

E. ANCHORAGE TO SUBSTRATE: TIE WIRE, NAILS, SCREWS, AND OTHER

METAL SUPPORTS, OF TYPE AND SIZE TO SUIT APPLICATION, TO

RIGIDLY SECURE MATERIALS IN PLACE.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT PROJECT CONDITIONS ARE APPROPRIATE FOR WORK OF

THIS SECTION TO COMMENCE.

3.02 FRAMING INSTALLATION

A. METAL FRAMING: COMPLY WITH ASTM C 754 AND MANUFACTURER'S

INSTRUCTIONS.

B. SUSPENDED CEILINGS AND SOFFITS: SPACE FRAMING AND FURRING

MEMBERS AT 16 INCHES (400 MM) ON CENTER.

1. LEVEL CEILING SYSTEM TO A TOLERANCE OF 1/1200.

2. LATERALLY BRACE ENTIRE SUSPENSION SYSTEM.

3. INSTALL BRACING AS REQUIRED AT ENTRY VESTIBULE TO

RESIST WIND UPLIFT.

C. STUDS: SPACE STUDS AS INDICATED.

1. EXTEND PARTITION FRAMING TO STRUCTURE AND TO OTHER

LOCATIONS AS INDICATED ON THE DRAWINGS.

2. PARTITIONS TERMINATING AT STRUCTURE: ATTACH

EXTENDED LEG TOP RUNNER TO STRUCTURE, MAINTAIN

CLEARANCE BETWEEN TOP OF STUDS AND STRUCTURE, AND

BRACE BOTH FLANGES OF STUDS WITH CONTINUOUS

BRIDGING.

3. SPACE STUD FRAMING AT RADIUS WALL TO PROVIDE UNIFORM

GYPSUM BOARD FINISH.

4. SPACE STUDS & FRAMING TO ACCOMODATE THROUGH WALL

AND RECESS EQUIPMENT IN WALL.

D. OPENINGS: REINFORCE OPENINGS AS REQUIRED FOR WEIGHT OF

DOORS OR OPERABLE PANELS, USING NOT LESS THAN DOUBLE

STUDS AT JAMBS.

E. BLOCKING: INSTALL BLOCKING FOR SUPPORT OF PLUMBING

FIXTURES, FIXTURES AND EQUIPMENT. COMPLY WITH SECTION

061000 FOR WOOD BLOCKING.

3.03 ACOUSTIC ACCESSORIES INSTALLATION

A. ACOUSTIC INSULATION: PLACE TIGHTLY WITHIN SPACES, AROUND

CUT OPENINGS, BEHIND AND AROUND ELECTRICAL AND MECHANICAL

ITEMS WITHIN PARTITIONS, AND TIGHT TO ITEMS PASSING THROUGH

PARTITIONS.

3.04 GYPSUM BOARD INSTALLATION

A. COMPLY WITH ASTM C 840 AND MANUFACTURER'S INSTRUCTIONS.

INSTALL TO MINIMIZE BUTT END JOINTS, ESPECIALLY IN HIGHLY

VISIBLE LOCATIONS.

B. SINGLE-LAYER NON-RATED: INSTALL GYPSUM BOARD IN MOST

ECONOMICAL DIRECTION, WITH ENDS AND EDGES OCCURRING OVER

FIRM BEARING.

C. GYPSUM SHEATHING: COMPLY WITH GA-253. INSTALL SHEATHING

HORIZONTALLY, WITH EDGES BUTTED TIGHT AND ENDS OCCURRING

OVER FIRM BEARING.

D. INSTALLATION ON METAL FRAMING: USE SCREWS FOR ATTACHMENT

OF ALL GYPSUM BOARD.

3.05 INSTALLATION OF TRIM AND ACCESSORIES

A. CONTROL JOINTS: PLACE CONTROL JOINTS CONSISTENT WITH LINES

OF BUILDING SPACES.

B. CORNER BEADS: INSTALL AT EXTERNAL CORNERS, USING LONGEST

PRACTICAL LENGTHS.

3.06 JOINT TREATMENT

A. FINISH GYPSUM BOARD IN ACCORDANCE WITH ASTM C 840. LEVEL 4

FINISH AT WALLS AND CEILINGS EXCEPT FOR LEVEL 4 FINISH AT

CEILING LOCATIONS INDICATED ON PLANS AND LEVEL 1 ABOVE

CEILINGS.

3.07 TOLERANCES

A. MAXIMUM VARIATION OF FINISHED GYPSUM BOARD SURFACE FROM

TRUE FLATNESS: 1/8 INCH IN 10 FEET (3 MM IN 3 M) IN ANY DIRECTION.

3.08 FINISH LEVEL SCHEDULE

A. LEVEL 1: ABOVE FINISHED CEILINGS CONCEALED FROM VIEW.

B. LEVEL 4: WALLS AND CEILINGS SCHEDULED TO RECEIVE PAINT

FINISH.

END OF SECTION

SECTION 093000 - TILING

PART 1 - GENERAL

1.1 SUMMARY

A. THIS SECTION INCLUDES THE FOLLOWING:

1. GLAZED WALL TILE.

2. QUARRY TILE AND BASE.

3. METAL EDGE STRIPS INSTALLED AS PART OF TILE

INSTALLATIONS.

1.2 EXTRA MATERIALS

A. FURNISH EXTRA MATERIALS DESCRIBED BELOW THAT MATCH

PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE

COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING

CONTENTS.

1. TILE AND TRIM UNITS: FURNISH QUANTITY OF FULL-SIZE UNITS

EQUAL TO 3 PERCENT OF AMOUNT INSTALLED, FOR EACH

TYPE, COMPOSITION, COLOR, PATTERN, AND SIZE INDICATED.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. PROVIDE PRODUCTS FROM MANUFACTURERS AS SCHEDULED ON

DRAWINGS.

2.2 TILE PRODUCTS

A. MANUFACTURERS: AS SCHEDULED ON DRAWINGS.

B. PROVIDE TRIM PIECES, BULLNOSE TILE, COVED BASEINSIDE AND

OUTSIDE CORNERS NECESSARY FOR PROJECT INSTALLATION.

2.3 SETTING AND GROUTING MATERIALS

A. AVAILABLE MANUFACTURERS:

1. BONSAL, W. R., COMPANY.

2. BOSTIK.

3. CUSTOM BUILDING PRODUCTS.

4. DAP, INC.

5. LATICRETE INTERNATIONAL INC.

6. MAPEI CORPORATION.

7. SOUTHERN GROUTS & MORTARS, INC.

8. SUMMITVILLE TILES, INC.

B. LATEX-PORTLAND CEMENT MORTAR (THIN SET): ANSI A118.4.

1. PREPACKAGED DRY-MORTAR MIX COMBINED WITH

LIQUID-LATEX ADDITIVE.

2. FOR WALL APPLICATIONS, PROVIDE NONSAGGING MORTAR.

C. POLYMER-MODIFIED TILE GROUT: ANSI A118.7, COLOR AS INDICATED.

2.4 MISCELLANEOUS MATERIALS

A. TRANSITION AND EDGE TRIMS. PROVIDE SCHLUTER TRIMS AS

INDICATED ON DRAWINGS.

PART 3 - EXECUTION

3.1 PREPARATION

A. REMOVE COATINGS, INCLUDING CURING COMPOUNDS AND OTHER

SUBSTANCES THAT CONTAIN SOAP, WAX, OIL, OR SILICONE, THAT ARE

INCOMPATIBLE WITH TILE-SETTING MATERIALS.

B. FILL CRACKS, HOLES, AND DEPRESSIONS WITH TROWELABLE

LEVELING AND PATCHING COMPOUND ACCORDING TO TILE-SETTING

MATERIAL MANUFACTURER'S WRITTEN INSTRUCTIONS.

C. REMOVE PROTRUSIONS, BUMPS, AND RIDGES BY SANDING OR

GRINDING.

D. BLENDING: FOR TILE EXHIBITING COLOR VARIATIONS, USE FACTORY

BLENDED TILE OR BLEND TILES AT PROJECT SITE BEFORE

INSTALLING.

E. FIELD-APPLIED TEMPORARY PROTECTIVE COATING: WHERE

INDICATED UNDER TILE TYPE OR NEEDED TO PREVENT GROUT FROM

STAINING OR ADHERING TO EXPOSED TILE SURFACES, PRECOAT

THEM WITH CONTINUOUS FILM OF TEMPORARY PROTECTIVE COATING,

TAKING CARE NOT TO COAT UNEXPOSED TILE SURFACES.

3.2 INSTALLATION, GENERAL

A. ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI

A108 SERIES "SPECIFICATIONS FOR INSTALLATION OF CERAMIC TILE"

THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS AND

TO METHODS INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES.

B. TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC

TILE INSTALLATION." COMPLY WITH TCA INSTALLATION METHODS

INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES.

C. EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND

EQUIPMENT AND FIXTURES TO FORM COMPLETE COVERING WITHOUT

INTERRUPTIONS, UNLESS OTHERWISE INDICATED. TERMINATE WORK

NEATLY AT OBSTRUCTIONS, EDGES, AND CORNERS WITHOUT

DISRUPTING PATTERN OR JOINT ALIGNMENTS.

D. ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM

CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE

SURFACES. GRIND CUT EDGES OF TILE ABUTTING TRIM, FINISH, OR

BUILT-IN ITEMS. FIT TILE CLOSELY TO ELECTRICAL OUTLETS, PIPING,

FIXTURES, AND OTHER PENETRATIONS SO PLATES, COLLARS, OR

COVERS OVERLAP TILE.

E. JOINTING PATTERN: LAY TILE IN GRID PATTERN, UNLESS OTHERWISE

INDICATED. ALIGN JOINTS WHEN ADJOINING TILES ON FLOOR, BASE,

WALLS, AND TRIM ARE SAME SIZE. LAY OUT TILE WORK AND CENTER

TILE FIELDS IN BOTH DIRECTIONS IN EACH SPACE OR ON EACH WALL

AREA. ADJUST TO MINIMIZE TILE CUTTING. PROVIDE UNIFORM JOINT

WIDTHS, UNLESS OTHERWISE INDICATED.

F. LAY OUT TILE WAINSCOTS TO NEXT FULL TILE BEYOND DIMENSIONS

INDICATED.

G. EXPANSION JOINTS: LOCATE EXPANSION JOINTS AND OTHER

SEALANT-FILLED JOINTS DURING INSTALLATION OF SETTING

MATERIALS, MORTAR BEDS, AND TILE. DO NOT SAW-CUT JOINTS

AFTER INSTALLING TILES.

1. LOCATE JOINTS IN TILE SURFACES DIRECTLY ABOVE JOINTS IN

CONCRETE SUBSTRATES.

2. PREPARE JOINTS AND APPLY SEALANTS TO COMPLY WITH

REQUIREMENTS IN DIVISION 07 SECTION "JOINT SEALANTS."

H. FOR INSTALLATIONS INDICATED BELOW, FOLLOW PROCEDURES IN

ANSI A108 SERIES TILE INSTALLATION STANDARDS FOR PROVIDING 95

PERCENT MORTAR COVERAGE.

1. TILE FLOORS IN WET AREAS.

2. TILE FLOORS COMPOSED OF TILES 8 BY 8 INCHES (200 BY 200

MM) OR LARGER.

3. TILE FLOORS COMPOSED OF RIB-BACKED TILES.

I. INSTALL TILE ON FLOORS WITH THE FOLLOWING JOINT WIDTHS:

1. PORCELAIN CERAMIC: 1/4 INCH (6.35 MM).

2. QUARRY TILE: 3/8 INCH (6.35 MM).

K. METAL EDGE STRIPS: INSTALL AT LOCATIONS INDICATED OR WHERE

EXPOSED EDGE OF TILE FLOORING MEETS CARPET, WOOD, OR OTHER

FLOORING THAT FINISHES FLUSH WITH TOP OF TILE.

L. INSTALL TILE ON WALLS WITH THE FOLLOWING JOINT WIDTHS:

1. GLAZED WALL TILE: 1/16 INCH (1.6 MM).

3.3 WALL TILE INSTALLATION SCHEDULE

A. INTERIOR WALL INSTALLATION, THIN-SET MORTAR, OVER GYPSUM

BOARD, TCA W243.

1. THIN-SET MORTAR: LAYTEX-PORTLAND CEMENT MORTAR.

2. GROUT: POLYMER-MODIFIED SANDED GROUT.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.5

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.5

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 12: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 095113 - ACOUSTICAL PANEL CEILINGS

PART 1 GENERAL

1.01 SECTION INCLUDES

A. SUSPENDED METAL GRID CEILING SYSTEM.

B. ACOUSTICAL UNITS.

1.02 REFERENCES

A. ASTM C 635 - STANDARD SPECIFICATION FOR THE MANUFACTURE,

PERFORMANCE, AND TESTING OF METAL SUSPENSION SYSTEMS FOR

ACOUSTICAL TILE AND LAY-IN PANEL CEILINGS, 2000.

B. ASTM C 636 - STANDARD PRACTICE FOR INSTALLATION OF METAL

CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN

PANELS, 1996.

C. ASTM E 1264 - STANDARD CLASSIFICATION FOR ACOUSTICAL CEILING

PRODUCTS, 1998.

D. LATEST EDITION OF CISCA - GUIDELINES FOR SIESMIC RESTRAINT FOR

DIRECT HUNG SUSPENDED CEILING ASSEMBLIES.

1.03 QUALITY ASSURANCE

A. ACOUSTICAL UNIT MANUFACTURER QUALIFICATIONS: COMPANY

SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS

SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE.

1.04 ENVIRONMENTAL REQUIREMENTS

A. MAINTAIN UNIFORM TEMPERATURE OF MINIMUM 60 DEGREES F (16

DEGREES C), AND MAXIMUM HUMIDITY OF 40 PERCENT PRIOR TO,

DURING, AND AFTER ACOUSTICAL UNIT INSTALLATION.

1.05 PROJECT CONDITIONS

A. SEQUENCE WORK TO ENSURE ACOUSTICAL CEILINGS ARE NOT

INSTALLED UNTIL BUILDING IS ENCLOSED, SUFFICIENT HEAT IS

PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED, AND

OVERHEAD WORK IS COMPLETED, TESTED, AND APPROVED.

B. INSTALL ACOUSTICAL UNITS AFTER INTERIOR WET WORK IS DRY.

PART 2 PRODUCTS

2.01 ACOUSTICAL UNITS

A. REFER TO DRAWING SCHEDULE.

2.02 SUSPENSION SYSTEM(S)

A. MANUFACTURERS:

1. DONN DX OR EQUIVALENT STANDARD 15/16", COLOR WHITE

2. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT

REQUIREMENTS.

B. SUSPENSION SYSTEMS - GENERAL: ASTM C 635, DIE CUT AND

INTERLOCKING COMPONENTS, WITH STABILIZER BARS, CLIPS,

SPLICES, PERIMETER MOLDINGS, AND HOLD DOWN CLIPS AS

REQUIRED.

2.03 ACCESSORIES

A. SUPPORT CHANNELS AND HANGERS: GALVANIZED STEEL, SIZE AND

TYPE TO SUIT APPLICATION AND CEILING SYSTEM FLATNESS

REQUIREMENT SPECIFIED.

B. PERIMETER MOLDINGS: SAME MATERIAL AND FINISH AS GRID.

C. TOUCH-UP PAINT: TYPE AND COLOR TO MATCH ACOUSTICAL AND

GRID UNITS.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK.

B. VERIFY THAT LAYOUT OF HANGERS WILL NOT INTERFERE WITH

OTHER WORK.

3.02 INSTALLATION - SUSPENSION SYSTEM

A. INSTALL SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C 636 AND

MANUFACTURER'S INSTRUCTIONS AND AS SUPPLEMENTED IN THIS

SECTION.

B. RIGIDLY SECURE SYSTEM, INCLUDING INTEGRAL MECHANICAL AND

ELECTRICAL COMPONENTS, FOR MAXIMUM DEFLECTION OF 1:360.

C. INSTALL AFTER MAJOR ABOVE-CEILING WORK IS COMPLETE.

COORDINATE THE LOCATION OF HANGERS WITH OTHER WORK.

D. HANG SUSPENSION SYSTEM INDEPENDENT OF WALLS, COLUMNS,

DUCTS, PIPES AND CONDUIT. WHERE CARRYING MEMBERS ARE

SPLICED, AVOID VISIBLE DISPLACEMENT OF FACE PLANE OF

ADJACENT MEMBERS.

E. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR

SPACING OF HANGERS, REINFORCE THE NEAREST AFFECTED

HANGERS AND RELATED CARRYING CHANNELS TO SPAN THE EXTRA

DISTANCE.

F. DO NOT SUPPORT COMPONENTS ON MAIN RUNNERS OR CROSS

RUNNERS IF WEIGHT CAUSES TOTAL DEAD LOAD TO EXCEED

DEFLECTION CAPABILITY.

G. SUPPORT FIXTURE LOADS USING SUPPLEMENTARY HANGERS

LOCATED WITHIN 6 INCHES (150 MM) OF EACH CORNER, OR SUPPORT

COMPONENTS INDEPENDENTLY.

H. DO NOT ECCENTRICALLY LOAD SYSTEM OR INDUCE ROTATION OF

RUNNERS.

I. PERIMETER MOLDING: INSTALL AT INTERSECTION OF CEILING AND

VERTICAL SURFACES AND AT JUNCTIONS WITH OTHER

INTERRUPTIONS.

1. USE LONGEST PRACTICAL LENGTHS.

2. OVERLAP AND RIVET CORNERS.

3.03 INSTALLATION - ACOUSTICAL UNITS

A. INSTALL ACOUSTICAL UNITS IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

B. FIT ACOUSTICAL UNITS IN PLACE, FREE FROM DAMAGED EDGES OR

OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION.

C. FIT BORDER TRIM NEATLY AGAINST ABUTTING SURFACES.

D. INSTALL UNITS AFTER ABOVE-CEILING WORK IS COMPLETE.

E. INSTALL ACOUSTICAL UNITS LEVEL, IN UNIFORM PLANE, AND FREE

FROM TWIST, WARP, AND DENTS.

F. CUTTING ACOUSTICAL UNITS:

1. CUT TO FIT IRREGULAR GRID AND PERIMETER EDGE TRIM.

2. MAKE FIELD CUT EDGES OF SAME PROFILE AS FACTORY

EDGES.

3. DOUBLE CUT AND FIELD PAINT EXPOSED REVEAL EDGES.

G. INSTALL HOLD-DOWN CLIPS ON PANELS WITHIN 20 FT (6 M) OF AN

EXTERIOR DOOR.

3.04 ERECTION TOLERANCES

A. MAXIMUM VARIATION FROM FLAT AND LEVEL SURFACE: 1/8 INCH IN 10

FEET (3 MM IN 3 M).

B. MAXIMUM VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY

ECCENTRIC LOADS: 2 DEGREES.

END OF SECTION

RESILIENT FLOORING - 096500

PART 1 GENERAL (NOT USED)

PART 2 PRODUCTS

2.01 VCT MEETING FEDERAL SPECIFICATION SS-T-312B (1) TYPE IV,

COMPOSITION 1

A. TILE: AS MANUFACTURED BY ARMSTRONG

1. SIZE: 12"X12"X1/8"

B. TEXTURES/COLORS: SEE FINISH SCHEDULE.

C. SHEET VINYL: AS MANUFACTURED BY ARMSTRONG

1. SIZE: 6' WIDE (.080") THICK

2. COLOR: REFER TO FINISH SCHEDULE.

3. SEAMS: ALL SEAMS TO BE HEAT WELDED AS REQUIRED BY

MANUFACTURER

D. VINYL BASE WITH COVE: AS MANUFACTURED BY ARMSTRONG

1. HEIGHT: 4"

2. THICKNESS: .080"

3. COLOR: REFER TO FINISH SCHEDULE.

E. ADHESIVE: PER MANUFACTURERS RECOMMENDATION

F. INITIAL MAINTENANCE AFTER INSTALLATION: ARMSTRONG

COMMERCIAL VINYL COMPOSITION TILES ARE COATED WITH FAST

START FACTORY FINISH. IT DOES NOT REQUIRE REMOVAL AFTER

INSTALLATION. IT IS COMPATIBLE WITH COMMERCIAL FLOOR

POLISHES AND ELIMINATES THE NEED TO STRIP THE TILE.

G. IMMEDIATELY AFTER VCT INSTALLATION, AND PRIOR TO STORE

FIXTURE DELIVERY, G.C. SHALL TO DO THE FOLLOWING:

1. SWEEP OR VACUUM THE FLOOR THOROUGHLY.

2. DAMP-MOP THE FLOOR WITH A NEUTRAL DETERGENT

SOLUTION SUCH AS ARMSTRONG S-485 FLOOR CLEANER,

WHILE CAREFULLY REMOVING BLACK MARKS AND EXCESSIVE

SOIL. DO NOT MACHINE SCRUB THE FLOOR FOR AT LEAST

FOUR TO FIVE DAYS AFTER INSTALLATION, TO PREVENT

EXCESS MOISTURE FROM INTERFERING WITH THE ADHESIVE

BOND.

3. APPLY (2) COATS OF A HIGH-QUALITY COMMERCIAL FLOOR

POLISH SUCH AS ARMSTRONG S-480 FLOOR POLISH OR A

HIGH-QUALITY STAIN-RESISTANT SEALER SUCH AS

ARMSTRONG S-495 FLOOR SEALER. ALLOW APPROPRIATE

DRYING TIME BETWEEN APPLICATIONS. POLISH TO BE MOP

APPLIED AS REQUIRED BY POLISH MANUFACTURER.

4. IN NO INSTANCE SHALL NEW VCT BE PLACED OVER EXISTING

VCT. EXISTING VCT SHALL BE REMOVED AND SLAB PREPARED

TO RECEIVE NEW VCT.

END OF SECTION

DECORATIVE FIBERGLASS REINFORCED

WALL PANELS - 097200

PART 1 GENERAL (NOT USED)

PART 2 PRODUCTS

2.01 FIBERGLASS WALL PANELS

A. MANUFACTURER: MARLITE

1. FIBERGLASS REINFORCED THERMOSETTING POLYESTER

RESIN PANEL SHEETS COMPLYING WITH ASTM D 5319.

2. COATING: MULTI LAYER PRINT, PRIMER AND FINISH COATS.

3. DIMENSIONS:

a. THICKNESS - 0.090 INCH (2.29MM) NOMINAL

b. WIDTH - 4'-0” (1.22M) NOMINAL

c. LENGTH -8'-0” (2.4M) NOMINAL

4. COLOR AND FINISH

d. COLOR: AS INDICATED ON PLANS

e. SURFACE PEBBLED (INDICATED BY “P” DESIGNATION)

5. MOLDINGS-PVC: EXTRUDED PVC TRIM PROFILES FOR .090 INCH

THICK PANELS.

a. M 350 INSIDE CORNER

b. M 365 DIVISION

c. M 370 EDGE

c.1. COLOR: AS INDICATED ON PLANS

6. OUTSIDE CORNER GUARD; PROVIDE GRAND ENTRANCE

OUTSIDE CORNER GUARDS REFER TO SECTION 102600 WALL

AND DOOR PROTECTION

7. FASTENERS: NON-STAINING NYLON DRIVE RIVETS.

a. MATCH WALL COLORS.

b. LENGTH TO SUIT PROJECT CONDITIONS.

8. ADHESIVE: EITHER OF THE FOLLOWING CONSTRUCTION

ADHESIVES COMPLYING WITH ASTM C 557.

a. MARLITE C-551 FRP ADHESIVE - WATER- RESISTANT,

NON-FLAMMABLE ADHESIVE

PART 3: EXECUTION

A. PREPARATION

1. LEVEL WALL SURFACES TO PANEL MANUFACTURER'S

REQUIREMENTS. REMOVE PROTRUSIONS AND FILL

INDENTATIONS.

2. STORE PANELS AND TRIM LYING FLAT, UNDER COVER AND

PROTECTED FROM THE ELEMENTS. ALLOW PANELS TO

ACCLIMATE TO ROOM TEMPERATURE (70°) FOR 48 HOURS

PRIOR TO INSTALLATION.

B. INSTALLATION

1. COMPLY WITH MANUFACTURER'S RECOMMENDED

PROCEDURES AND INSTALLATION SEQUENCE.

2. CAULK TOP AND BOTTOM OF WALL PANEL TRIM AT WALL.

3. CAULK TOP AND BOTTOM OF CORNER GUARD AT WALL.

C. CLEANING

1. REFER TO MANUFACTURER'S SPECIFIC CLEANING

RECOMMENDATIONS DO NOT USE ABRASIVE CLEANERS.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.6

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.6

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 13: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

SECTION 099100 - PAINTING

PART 1 GENERAL

1.01 SECTION INCLUDES

A. SURFACE PREPARATION.

B. FIELD APPLICATION OF PAINTS AND OTHER COATINGS.

C. SEE SCHEDULE - SURFACES TO BE FINISHED, AT END OF SECTION.

1.02 REFERENCES

A. ASTM D 16 - STANDARD TERMINOLOGY FOR PAINT, RELATED

COATINGS, MATERIALS, AND APPLICATIONS, 2000.

1.03 QUALITY ASSURANCE

A. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN

MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH

MINIMUM THREE YEARS DOCUMENTED EXPERIENCE.

B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN

PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS

EXPERIENCE.

1.04 REGULATORY REQUIREMENTS

A. CONFORM TO APPLICABLE CODE FOR FLAME AND SMOKE RATING

REQUIREMENTS FOR PRODUCTS AND FINISHES.

1.05 DELIVERY, STORAGE, AND PROTECTION

A. DELIVER PRODUCTS TO SITE IN SEALED AND LABELED CONTAINERS,

INSPECT TO VERIFY ACCEPTABILITY.

B. CONTAINER LABEL: INCLUDE MANUFACTURER'S NAME, TYPE OF

PAINT, BRAND NAME, LOT NUMBER, BRAND CODE, COVERAGE,

SURFACE PREPARATION, DRYING TIME, CLEANUP REQUIREMENTS,

COLOR DESIGNATION, AND INSTRUCTIONS FOR MIXING AND

REDUCING.

C. PAINT MATERIALS: STORE AT MINIMUM AMBIENT TEMPERATURE OF 45

DEGREES F (7 DEGREES C) AND A MAXIMUM OF 90 DEGREES F (32

DEGREES C), IN VENTILATED AREA, AND AS REQUIRED BY

MANUFACTURER'S INSTRUCTIONS.

1.06 ENVIRONMENTAL REQUIREMENTS

A. DO NOT APPLY MATERIALS WHEN SURFACE AND AMBIENT

TEMPERATURES ARE OUTSIDE THE TEMPERATURE RANGES

REQUIRED BY THE PAINT PRODUCT MANUFACTURER.

B. DO NOT APPLY EXTERIOR COATINGS DURING RAIN OR SNOW, OR

WHEN RELATIVE HUMIDITY IS OUTSIDE THE HUMIDITY RANGES

REQUIRED BY THE PAINT PRODUCT MANUFACTURER.

C. MINIMUM APPLICATION TEMPERATURES FOR LATEX PAINTS: 45

DEGREES F (7 DEGREES C) FOR INTERIORS, 50 DEGREES F (10

DEGREES C) FOR EXTERIOR, UNLESS REQUIRED OTHERWISE BY

MANUFACTURER'S INSTRUCTIONS.

D. PROVIDE LIGHTING LEVEL OF 80 FT CANDLES (860 LX) MEASURED

MID-HEIGHT AT SUBSTRATE SURFACE.

1.07 EXTRA MATERIALS

A. SEE SECTION 016000 - PRODUCT REQUIREMENTS, FOR ADDITIONAL

PROVISIONS.

B. SUPPLY 1 GALLON (4 L) OF EACH COLOR, STORE WHERE DIRECTED.

C. LABEL EACH CONTAINER WITH COLOR IN ADDITION TO THE

MANUFACTURER'S LABEL.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. SHERWIN WILLIAMS: WWW.SHERWIN-WILLIAMS.COM.

B. THE MINWAX COMPANY: WWW.MINWAX.COM.

C. SUBSTITUTIONS: SEE SECTION 016000 - PRODUCT REQUIREMENTS.

2.02 PAINTS AND COATINGS - GENERAL

A. PAINTS AND COATINGS: READY MIXED, EXCEPT FIELD-CATALYZED

COATINGS. PREPARE PIGMENTS:

1. TO A SOFT PASTE CONSISTENCY, CAPABLE OF BEING READILY

AND UNIFORMLY DISPERSED TO A HOMOGENEOUS COATING.

2. FOR GOOD FLOW AND BRUSHING PROPERTIES.

3. CAPABLE OF DRYING OR CURING FREE OF STREAKS OR SAGS.

2.03 ACCESSORY MATERIALS

A. ACCESSORY MATERIALS: LINSEED OIL, SHELLAC, TURPENTINE, PAINT

THINNERS AND OTHER MATERIALS NOT SPECIFICALLY INDICATED BUT

REQUIRED TO ACHIEVE THE FINISHES SPECIFIED, COMMERCIAL

QUALITY.

B. PATCHING MATERIAL: LATEX FILLER.

C. FASTENER HEAD COVER MATERIAL: LATEX FILLER.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AS

INSTRUCTED BY THE PRODUCT MANUFACTURER.

B. EXAMINE SURFACES SCHEDULED TO BE FINISHED PRIOR TO

COMMENCEMENT OF WORK. REPORT ANY CONDITION THAT MAY

POTENTIALLY AFFECT PROPER APPLICATION.

C. TEST SHOP-APPLIED PRIMER FOR COMPATIBILITY WITH SUBSEQUENT

COVER MATERIALS.

3.02 PREPARATION

A. SURFACE APPURTENANCES: REMOVE OR MASK ELECTRICAL PLATES,

HARDWARE, LIGHT FIXTURE TRIM, ESCUTCHEONS, AND FITTINGS

PRIOR TO PREPARING SURFACES OR FINISHING.

B. SURFACES: CORRECT DEFECTS AND CLEAN SURFACES WHICH

AFFECT WORK OF THIS SECTION. REMOVE OR REPAIR EXISTING

COATINGS THAT EXHIBIT SURFACE DEFECTS.

C. MARKS: SEAL WITH SHELLAC THOSE WHICH MAY BLEED THROUGH

SURFACE FINISHES.

D. IMPERVIOUS SURFACES: REMOVE MILDEW BY SCRUBBING WITH

SOLUTION OF TETRA-SODIUM PHOSPHATE AND BLEACH. RINSE WITH

CLEAN WATER AND ALLOW SURFACE TO DRY.

E. CONCRETE AND UNIT MASONRY SURFACES TO BE PAINTED: REMOVE

DIRT, LOOSE MORTAR, SCALE, SALT OR ALKALI POWDER, AND OTHER

FOREIGN MATTER. REMOVE OIL AND GREASE WITH A SOLUTION OF

TRI-SODIUM PHOSPHATE, RINSE WELL AND ALLOW TO DRY. REMOVE

STAINS CAUSED BY WEATHERING OF CORRODING METALS WITH A

SOLUTION OF SODIUM METASILICATE AFTER THOROUGHLY WETTING

WITH WATER. ALLOW TO DRY.

F. GYPSUM BOARD SURFACES TO BE PAINTED: FILL MINOR DEFECTS

WITH FILLER COMPOUND. SPOT PRIME DEFECTS AFTER REPAIR.

G. GALVANIZED SURFACES TO BE PAINTED: REMOVE SURFACE

CONTAMINATION AND OILS AND WASH WITH SOLVENT. APPLY COAT

OF ETCHING PRIMER.

H. UNCOATED STEEL AND IRON SURFACES TO BE PAINTED: REMOVE

GREASE, MILL SCALE, WELD SPLATTER, DIRT, AND RUST. WHERE

HEAVY COATINGS OF SCALE ARE EVIDENT, REMOVE BY HAND WIRE

BRUSHING OR SANDBLASTING, CLEAN BY WASHING WITH SOLVENT.

APPLY A TREATMENT OF PHOSPHORIC ACID SOLUTION, ENSURING

WELD JOINTS, BOLTS, AND NUTS ARE SIMILARLY CLEANED. PRIME

PAINT ENTIRE SURFACE, SPOT PRIME AFTER REPAIRS

I. SHOP-PRIMED STEEL SURFACES TO BE FINISH PAINTED: SAND AND

SCRAPE TO REMOVE LOOSE PRIMER AND RUST. FEATHER EDGES TO

MAKE TOUCH-UP PATCHES INCONSPICUOUS. CLEAN SURFACES WITH

SOLVENT. PRIME BARE STEEL SURFACES. RE-PRIME ENTIRE

SHOP-PRIMED ITEM.

J. METAL DOORS TO BE PAINTED: PRIME METAL DOOR TOP AND

BOTTOM EDGE SURFACES.

3.03 APPLICATION

A. APPLY PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S

INSTRUCTIONS.

B. DO NOT APPLY FINISHES TO SURFACES THAT ARE NOT DRY. ALLOW

APPLIED COATS TO DRY BEFORE NEXT COAT IS APPLIED.

C. APPLY EACH COAT TO UNIFORM APPEARANCE. APPLY EACH COAT OF

PAINT SLIGHTLY DARKER THAN PRECEDING COAT UNLESS

OTHERWISE APPROVED.

D. VACUUM CLEAN SURFACES OF LOOSE PARTICLES. USE TACK CLOTH

TO REMOVE DUST AND PARTICLES JUST PRIOR TO APPLYING NEXT

COAT.

3.04 FINISHING MECHANICAL AND ELECTRICAL EQUIPMENT

A. REFER TO SECTION 150500 FOR SCHEDULE OF COLOR CODING OF

EQUIPMENT, DUCT WORK, PIPING, AND CONDUIT.

B. PAINT SHOP-PRIMED EQUIPMENT, WHERE INDICATED.

C. REMOVE UNFINISHED LOUVERS, GRILLES, COVERS, AND ACCESS

PANELS ON MECHANICAL AND ELECTRICAL COMPONENTS AND PAINT

SEPARATELY.

D. FINISH EQUIPMENT, PIPING, CONDUIT, AND EXPOSED DUCT WORK IN

COLORS ACCORDING TO THE COLOR CODING SCHEME INDICATED.

E. REINSTALL ELECTRICAL COVER PLATES, HARDWARE, LIGHT FIXTURE

TRIM, ESCUTCHEONS, AND FITTINGS REMOVED PRIOR TO FINISHING.

3.05 CLEANING

A. COLLECT WASTE MATERIAL WHICH MAY CONSTITUTE A FIRE HAZARD,

PLACE IN CLOSED METAL CONTAINERS, AND REMOVE DAILY FROM

SITE.

3.06 SCHEDULE - SURFACES TO BE FINISHED

A. DO NOT PAINT OR FINISH THE FOLLOWING ITEMS:

1. ITEMS FULLY FACTORY-FINISHED UNLESS SPECIFICALLY NOTED.

2. FIRE RATING LABELS, EQUIPMENT SERIAL NUMBER AND

CAPACITY LABELS.

B. PAINT THE SURFACES DESCRIBED BELOW UNDER SCHEDULE - PAINT

SYSTEMS.

C. MECHANICAL AND ELECTRICAL: USE PAINT SYSTEMS DEFINED FOR

THE SUBSTRATES TO BE FINISHED.

1. PAINT ALL INSULATED AND EXPOSED PIPES OCCURRING IN

FINISHED AREAS TO MATCH BACKGROUND SURFACES, UNLESS

OTHERWISE INDICATED.

2. PAINT SHOP-PRIMED ITEMS OCCURRING IN FINISHED AREAS.

3.07 SCHEDULE- PAINT SYSTEMS

A. INTERIOR WALLS - LOW ODOR/ LOW VOC, LATEX BASED EGGSHELL

UNLESS NOTED OTHERWISE IN FINISH SCHEDULE.

COAT #1 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX PRIMER, B28W2200 (4 MIL WET, 1.2 MIL DRY).

COAT #2 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX EG-SHELL, B20W651 (4 MIL WET, 1.5 MIL DRY).

COAT #3 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX EG-SHELL, B20W651 (4 MIL WET, 1.5 MIL DRY).

B. WOOD TRIM AND DOORS - LOW-ODOR/LOW VOC, LATEX BASED

SEMI-GLOSS.

COAT #1 SHERWIN WILLIAMS PREPRITE PROBLOCK LATEX

SEMI-GLOSS, B51S= SERIES (4 MIL WET, 1.4 MIL DRY).

COAT #2 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX SEMI-GLOSS, B31-600 SERIES (4 MIL WET, 1.6 MIL DRY)

COAT #3 SHERWIN WILLIAMS PROMAR 200 LATEX

SEMI-GLOSS, B31W200 SERIES. (4 MIL. WET, 1.5 MIL. DRY)

C. INTERIOR METAL DOORS, FRAMES, BOLLARDS, BUILDING COLUMNS

NOT AT ROOF STRUCTURE, - LOW-ODOR/LOWER VOC, LATEX BASED

SEMI-GLOSS.

COAT #1 SHERWIN WILLIAMS PRO INDUSTRIAL PRO-CRYL

UNIVERSAL PRIMER, B66-310 SERIES (5-10 MILS WET, 2-4 MILS

DRY).

COAT #2 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX SEMI-GLOSS, B31-600 SERIES (4 MIL WET, 1.6 MIL DRY).

COAT #3 SHERWIN WILLIAMS PROGREEN 200 INTERIOR

LATEX SEMI-GLOSS, B31-600 SERIES (4 MIL WET, 1.6 MIL DRY).

E. EXTERIOR METAL DOORS, FRAMES AND BOLLARDS - SEMI-GLOSS

ACRYLIC COATING.

COAT #1 SHERWIN WILLIAMS PRO INDUSTRIAL PRO-CRYL

UNIVERSAL PRIMER, B66-310 SERIES (5-10 MILS WET, 2-4 MILS

DRY).

COAT #2 SHERWIN WILLIAMS METALATEX ACRYLIC

SEMI-GLOSS, B42 SERIES (4 MIL WET, 1.5 MIL DRY).

COAT #3 SHERWIN WILLIAMS METALATEX ACRYLIC

SEMI-GLOSS, B42 SERIES (4 MIL WET, 1.5 MIL DRY).

F. CONCRETE FLOORS - EXPOSED CONCRETE FLOORS SHALL RECEIVE

TWO COATS OF HARDENER/SEALER A-H 3WAY SEALER WB MFG. BY

ANTI-HYDRO INTERNATIONAL INC. 1-800-777-1773

G. WALL GRAPHIC PAINT STRIPES. PAINT SPECIFICATION PER FINISH

SCHEDULE. INSTALL NUMBER OF COATS REQUIRED FOR COMPLETE

COVERAGE OF SUBSTRATE COLOR -- MINIMUM OF TWO COATS.

H. METAL ROOF DECK - DRYFALL WATERBORNE TOPCOATS

COAT #1 SHERWIN WILLIAMS DRYFALL WATERBORNE

TOPCOATS, S-W DTM ACRYLIC PRIMER/FINISH, B66W1 (2.5-4 MILS

DRY PER COAT)

COAT #2 SHERWIN WILLIAMS WATERBORNE TOPCOATS

EGGSHELL, S-W WATERBORNE ACRYLIC DRYFALL, B42W2 (7 MILS

WET, 3 MILS DRY)

END OF SECTION

SECTION 099723 - CONCRETE SEALERS

PART 1 GENERAL

1.1 SUMMARY

A. THIS SECTION SPECIFIES AN APPLIED SEALER FOR HORIZONTAL

CAST-IN-PLACE CONCRETE SURFACES.

B. RELATED SECTIONS: REFER TO THE FOLLOWING SPECIFICATION

SECTIONS FOR COORDINATION.

1. SECTION 033000 - CAST-IN-PLACE CONCRETE.

1.2 SUBMITTALS

A. PRODUCT DATA: SUBMIT MANUFACTURER'S PRODUCT DATA AND

INSTALLATION INSTRUCTIONS.

1.3 QUALITY ASSURANCE

A. MANUFACTURER: MINIMUM 10 YEARS EXPERIENCE PRODUCING

CONCRETE COATINGS.

B. SUITABILITY OF SUBSTRATE: CONCRETE SURFACE MUST BE CLEAN

AND DRY WITH ALL STAINS, OIL, GREASE, DUST AND DIRT REMOVED

PRIOR TO APPLICATION. A THOROUGH PRESSURE WASHING IS HIGHLY

RECOMMENDED.

D. REGULATORY REQUIREMENTS: COMPLY WITH REQUIREMENTS OF

AUTHORITIES HAVING JURISDICTION AND APPLICABLE CODES AT THE

LOCATION OF THE PROJECT.

1.4 DELIVERY, STORAGE AND HANDLING

A. DELIVER MATERIALS AND PRODUCTS IN UNOPENED FACTORY

LABELED PACKAGES. PROTECT FROM DAMAGE.

B. STORE IN A SAFE PLACE, OUT OF DIRECT SUNLIGHT. KEEP

CONTAINERS TIGHTLY SEALED. DO NOT ALLOW PRODUCT TO FREEZE.

USE WITHIN MANUFACTURER'S RECOMMENDED SHELF LIFE,

APPROXIMATELY 12 MONTHS.

PART 2 - PRODUCTS

2.1 MATERIALS

A. V-SEAL 101 MULTI SURFACE

B. PERFORMANCE: CONCRETE SEALERS SHALL MEET OR EXCEED THE

FOLLOWING:

1. COVERAGE: AS RECOMMENDED BY MANUFACTURER.

2. MOISTURE RETENTION, TEST ASTM C 309: 0.21 KG/M² AT 200 FT²

PER GALLON AND 0.32 KG/M² AT 300 FT² PER GALLON.

3. GASOLINE RESISTANCE: SLIGHT DULLING AFTER15-MINUTE

EXPOSURE (PONDING).

4. TG: 50°C.

5. TUKON HARDNESS: 30 MINUTES AT 180°F, 9.3; 30 MINUTES AT

300°F, 13.7.

6. PENCIL HARDNESS: 30 MINUTES AT 180°F, F; 30 MINUTES AT

300°F, H.

7. SPRAY CONDITIONS, VISCOSITY: 19 SECONDS, NO. 2 ZHAN CUP.

8. ABRASION RESISTANCE: 160 MG LOST, CS-17 WHEEL, 1000 G

LOAD, 1000 CYCLES

PART 3 - EXECUTION

3.1 PREPARATION

A. INSPECTION: PRIOR TO START OF APPLICATION, INSPECT EXISTING

CONDITIONS TO ENSURE SURFACES ARE SUITABLE FOR

INSTALLATION INCLUDING THE FOLLOWING:

1. CONCRETE HAS CURED FOR A MINIMUM OF 28 DAYS PRIOR TO

APPLICATION OF SEALER.

2. SURFACE IS COMPLETELY FREE OF SEALERS, OILS, DIRT, PAINT,

ALKALI, PENETRATING SEALERS AND FOREIGN MATERIALS THAT

WOULD PREVENT THE SEALER FROM PENETRATING THE

CONCRETE SURFACE.

3. CONCRETE HAS BEEN SWEPT CLEAN.

4. TEST AREA HAS BEEN APPROVED.

3.2 APPLICATION

A. CONCRETE SEALER: STRICTLY COMPLY WITH MANUFACTURER'S

INSTALLATION RECOMMENDATIONS INCLUDING THE FOLLOWING.

1. CLEAN SURFACE AS RECOMMENDED BY MANUFACTURER.

2. ALL CONCRETE FLATWORK DESIGNATED AS BEING SEALED IN

THE PLANS AND SPECIFICATIONS SHALL BE SEALED WITH 2-3

EVEN COATS OF SEALER, AT THE RATE OF APPROXIMATELY 150

TO 200 SQUARE FEET PER GALLON.

3.3 CLEANING AND PROTECTION

PROTECTION: DO NOT COVER, BUT PROTECT FLOOR AREA FROM PAINT AND OTHER

CONTAMINATES THAT COULD INHIBIT THE SEALER.

END OF SECTION

SECTION 102600 - WALL AND DOOR PROTECTION

PART 1 - GENERAL

1.1 PRODUCTS

A. WALL GUARDS

1. PLASTIC CRASH RAIL: WITH RETAINER CLIPS

a. SURFACE MOUNTED

2. MANUFACTURER:

a. GRAND ENTRANCE: SCR-50 CRASH RAIL, INSTALLED

PER MANUFACTURER'S RECOMMENDATIONS.

b. MCCUE CORPORATION, CART STOP GR; INSTALLED PER

MANUFACTURER'S RECOMMENDATIONS. LENGTH AS

INDICATED ON DRAWINGS.

c. MCCUE CORPORATION, CART STOP SP; INSTALLED PER

MANUFACTURER'S RECOMMENDATIONS. LENGTH AS

INDICATED ON DRAWINGS.

CORNER GUARDS

1. SURFACE MOUNTED, RESILIENT, PLASTIC TYPE: 4 FEET HIGH,

USING RETAINER CLIPS.

2. MANUFACTURER:

a. GRAND ENTRANCE: VA SERIES CORNER GUARDS.

END OF SECTION

SECTION 102800 - TOILET, BATH AND LAUNDRY ACCESSORIES

PART 1 GENERAL

1.01 SECTION INCLUDES

A. GRAB BARS.

1.02 RELATED SECTIONS

A. SECTION 061000-WOOD BLOCKING AND CURBING: CONCEALED

SUPPORTS FOR ACCESSORIES, INCLUDING IN WALL FRAMING AND

PLATES.

1.03 REFERENCES

1.04 SUBMITTALS

A. SEE SECTION 013000 - ADMINISTRATIVE REQUIREMENTS, FOR

SUBMITTAL PROCEDURES.

B. PRODUCT DATA: PROVIDE DATA ON ACCESSORIES DESCRIBING SIZE,

FINISH, DETAILS OF FUNCTION, ATTACHMENT METHODS.

1.05 COORDINATION

A. COORDINATE THE WORK WITH THE PLACEMENT OF INTERNAL WALL

REINFORCEMENT TO RECEIVE ANCHOR ATTACHMENTS.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. REFER TO SCHEDULE ON DRAWINGS.

B. OTHER ACCEPTABLE MANUFACTURERS:

1. SUBSTITUTIONS: SECTION 016000 - PRODUCT REQUIREMENTS.

PART 3 EXECUTION

3.01 EXAMINATION

A. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK.

B. VERIFY EXACT LOCATION OF ACCESSORIES FOR INSTALLATION.

C. VERIFY THAT FIELD MEASUREMENTS ARE AS INDICATED ON

DRAWINGS.

3.02 PREPARATION

A. DELIVER INSERTS AND ROUGH-IN FRAMES TO SITE FOR TIMELY

INSTALLATION.

B. PROVIDE TEMPLATES AND ROUGH-IN MEASUREMENTS AS REQUIRED.

3.03 INSTALLATION

A. INSTALL ACCESSORIES IN ACCORDANCE WITH MANUFACTURERS'

INSTRUCTIONS.

B. INSTALL PLUMB AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO

SUBSTRATE.

C. MOUNTING HEIGHTS AND LOCATIONS: AS REQUIRED BY

ACCESSIBILITY REGULATIONS AND AS INDICATED ON DRAWINGS

END OF SECTION

SECTION 104416 - FIRE EXTINGUISHERS

PART 1 - GENERAL

1.1 SUMMARY

A. SECTION INCLUDES PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS

AND MOUNTING BRACKETS FOR FIRE EXTINGUISHERS.

1.2 QUALITY ASSURANCE

A. NFPA COMPLIANCE: FABRICATE AND LABEL FIRE EXTINGUISHERS TO

COMPLY WITH NFPA 10, "PORTABLE FIRE EXTINGUISHERS."

B. FIRE EXTINGUISHERS: LISTED AND LABELED FOR TYPE, RATING, AND

CLASSIFICATION BY AN INDEPENDENT TESTING AGENCY ACCEPTABLE

TO AUTHORITIES HAVING JURISDICTION.

1.3 WARRANTY

A. SPECIAL WARRANTY: MANUFACTURER'S STANDARD FORM IN WHICH

MANUFACTURER AGREES TO REPAIR OR REPLACE FIRE

EXTINGUISHERS THAT FAIL IN MATERIALS OR WORKMANSHIP WITHIN

SPECIFIED WARRANTY PERIOD.

1. FAILURES INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:

a. FAILURE OF HYDROSTATIC TEST ACCORDING TO NFPA

10.

b. FAULTY OPERATION OF VALVES OR RELEASE LEVERS.

2. WARRANTY PERIOD: MANUFACTURER'S STANDARD FORM AND

TERM.

PART 2 - PRODUCTS

2.1 PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS

A. FIRE EXTINGUISHERS: TYPE, SIZE, AND CAPACITY FOR EACH

MOUNTING BRACKET INDICATED.

1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH

REQUIREMENTS, AVAILABLE MANUFACTURERS OFFERING

PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK

INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING:

a. ANSUL INCORPORATED, TYCO INTERNATIONAL LTD.

b. BUCKEYE FIRE EQUIPMENT COMPANY.

c. LARSEN'S MANUFACTURING COMPANY.

d. MOON-AMERICAN.

e. PYRO-CHEM, TYCO SAFETY PRODUCTS.

2. INSTRUCTION LABELS: INCLUDE PICTORIAL MARKING SYSTEM

COMPLYING WITH NFPA 10, APPENDIX B.

B. DRY-CHEMICAL TYPE: UL-RATED 10 LB. ABC, WITH MONOAMMONIUM

PHOSPHATE BASED CHEMICAL IN STAINLESS-STEEL CONTAINER, WITH

PRESSURE-INDICATING GAGE.

2.2 MOUNTING BRACKETS

A. MOUNTING BRACKETS: MANUFACTURER'S STANDARD GALVANIZED

STEEL, DESIGNED TO SECURE FIRE EXTINGUISHER TO WALL OR

STRUCTURE, OF SIZES REQUIRED FOR TYPES AND CAPACITIES OF

FIRE EXTINGUISHERS INDICATED, WITH PLATED OR RED

BAKED-ENAMEL FINISH.

B. IDENTIFICATION: LETTERING COMPLYING WITH AUTHORITIES HAVING

JURISDICTION FOR LETTER STYLE, SIZE, SPACING, AND LOCATION.

LOCATE AS INDICATED BY ARCHITECT.

1. IDENTIFY BRACKET-MOUNTED FIRE EXTINGUISHERS WITH THE

WORDS "FIRE EXTINGUISHER" IN RED LETTER DECALS APPLIED

TO MOUNTING SURFACE.

a. ORIENTATION: VERTICAL.

PART 3 - EXECUTION

3.1 INSTALLATION

A. EXAMINE FIRE EXTINGUISHERS FOR PROPER CHARGING AND

TAGGING.

1. REMOVE AND REPLACE DAMAGED, DEFECTIVE, OR

UNDERCHARGED FIRE EXTINGUISHERS.

B. INSTALL FIRE EXTINGUISHERS AND MOUNTING BRACKETS IN

LOCATIONS INDICATED AND IN COMPLIANCE WITH REQUIREMENTS OF

AUTHORITIES HAVING JURISDICTION.

1. MOUNTING BRACKETS: 54 INCHES (1372 MM) ABOVE FINISHED

FLOOR TO TOP OF FIRE EXTINGUISHER.

C. MOUNTING BRACKETS: FASTEN MOUNTING BRACKETS TO SURFACES,

SQUARE AND PLUMB, AT LOCATIONS INDICATED.

END OF SECTION

SECTION 124816 - ENTRANCE FLOOR GRILLES

PART 1 - GENERAL

1.01 SUMMARY

A. SECTION INCLUDES: [ENTRANCE MATTING SYSTEMS, INCLUDING

VINYL FOOT GRIDS]

B. RELATED SECTIONS: SECTION(S) RELATED TO THIS SECTION

INCLUDE:

1. SECTION 033000 - CAST-IN-PLACE CONCRETE.

2. SECTION 087100 - DOOR HARDWARE.

1.02 REFERENCES

A. STANDARDS LISTED BY REFERENCE, INCLUDING REVISIONS BY

ISSUING AUTHORITY, FORM A PART OF THIS SPECIFICATION SECTION

TO EXTENT INDICATED. THE STANDARDS LISTED HERE ARE

IDENTIFIED WITH A DESIGNATION NUMBER, TITLE OR OTHER

DESIGNATION ESTABLISHED BY THE ISSUING AUTHORITY.

B. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM):

1. ASTM C1028 STATIC COEFFICIENT OF FRICTION

1.03 SYSTEM DESCRIPTION

A. PERFORMANCE REQUIREMENTS: PROVIDE VINYL GRID ENTRANCE

FLOOR MAT SYSTEM, WHICH HAS BEEN MANUFACTURED AND

INSTALLED TO MAINTAIN PERFORMANCE CRITERIA STATED BY

MANUFACTURER WITHOUT DEFECTS, DAMAGE OR FAILURE.

1.04 SUBMITTALS

A. GENERAL: SUBMIT LISTED SUBMITTALS IN ACCORDANCE WITH THE

CONDITIONS OF THE CONTRACT AND DIVISION 1 SUBMITTAL

PROCEDURES SECTION.

B. PRODUCT DATA: SUBMIT PRODUCT DATA, INCLUDING

MANUFACTURER'S SPECIFICATION SHEET AND INSTALLATION

INSTRUCTIONS FOR SPECIFIED PRODUCTS. INCLUDE METHODS OF

INSTALLATION AND SUBSTRATE PREPARATION FOR EACH TYPE OF

SUBSTRATE.

C. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS SHOWING LAYOUT,

PROFILES AND PRODUCT COMPONENTS, INCLUDING ANCHORAGE,

ACCESSORIES, FINISH COLORS, PATTERNS AND TEXTURES.

D. SAMPLES: SUBMIT SAMPLES FOR EACH TYPE AND COLOR OF

EXPOSED ENTRANCE MAT, FRAMES AND ACCESSORIES REQUIRED.

PROVIDE SAMPLES OF MAT MATERIALS.

E. QUALITY ASSURANCE SUBMITTALS: (1) CERTIFIED TEST REPORTS

SHOWING COMPLIANCE WITH SPECIFIED PERFORMANCE

CHARACTERISTICS AND PHYSICAL PROPERTIES, AND (2)

MANUFACTURER'S INSTALLATION INSTRUCTIONS.

F. CLOSEOUT SUBMITTALS: (1) CLEANING & MAINTENANCE DATA

(INCLUDE METHODS FOR MAINTAINING INSTALLED PRODUCTS AND

PRECAUTIONS AGAINST CLEANING MATERIALS AND METHODS

DETRIMENTAL TO FINISHES AND PERFORMANCE), AND (2) WARRANTY.

1.05 QUALITY ASSURANCE

A. INSTALLER: INSTALLER SHOULD BE HIGHLY EXPERIENCED IN

PERFORMING WORK OF THIS SECTION, HAVING PREVIOUSLY DONE

WORK SIMILAR TO THAT REQUIRED FOR THIS PROJECT.

1.06 SEQUENCING/SCHEDULING

A. ORDERING: COMPLY WITH MANUFACTURER'S ORDERING

INSTRUCTIONS AND LEAD-TIME REQUIREMENTS TO AVOID

CONSTRUCTION DELAYS.

B. DELIVERY: DELIVER MATERIALS IN MANUFACTURER'S ORIGINAL,

UNOPENED, UNDAMAGED PACKAGING.

C. STORAGE: STORE MATERIALS AT TEMPERATURE AND IN HUMIDITY

CONDITIONS RECOMMENDED BY MANUFACTURER AND PROTECT

FROM EXPOSURE TO HARMFUL WEATHER CONDITIONS.

D. INSTALLATION: EXCEPT AS OTHERWISE INDICATED HEREIN,

SEQUENCING OR SCHEDULING FOR PERFORMANCE OF WORK OF THIS

SECTION IN RELATION WITH OTHER WORK IS CONTRACTOR'S OPTION.

DELAY INSTALLATION OF MATS UNTIL NEAR TIME OF SUBSTANTIAL

COMPLETION FOR THE PROJECT.

1.07 PROJECT CONDITIONS

A. TEMPERATURE: MAINTAIN TEMPERATURE WHERE PRODUCTS WILL BE

INSTALLED BEFORE, DURING AND AFTER INSTALLATION AS

RECOMMENDED BY MANUFACTURER.

B. FIELD MEASUREMENTS: WHERE POSSIBLE, VERIFY ACTUAL

MEASUREMENTS BY FIELD MEASURING BEFORE FABRICATION AND

INCLUDE MEASUREMENTS IN SHOP DRAWINGS. TO AVOID

CONSTRUCTION DELAYS, COORDINATE FIELD MEASUREMENTS AND

FABRICATION SCHEDULE BASED UPON CONSTRUCTION PROGRESS.

PART 2 - PRODUCTS

2.01 ACCEPTABLE MANUFACTURER

A. PROVIDE ULTRA ENTRY BY:

MATS INC., PO BOX 839, 37 SHUMAN AVENUE, STOUGHTON, MA,

02072; TELEPHONE 800-628-7462 OR 781-344-1536; FAX 781-344-1537;

WWW.MATSINC.COM.

2.02 MATERIALS

A. VINYL FOOT GRILLE: CONSTRUCTED FROM 30 PERCENT

POST-INDUSTRIAL RECYCLED POLYVINYL CHLORIDE (PVC) IF GRAY OR

OTHER COLORS, AND UP TO 100 PERCENT POST-INDUSTRIAL

RECYCLED PVC IF BLACK. WELDED IN A NON-HINGED, GRILLE DESIGN

WITH AN EMBOSSED NON-SKID SURFACE, (NON-EMBOSSED SURFACES

NOT ACCEPTABLE) TO SIZES INDICATED WITH THE FOLLOWING

CHARACTERISTICS:

1. ULTRA ENTRY: EXTRUDED PVC GRID, GRAY COLOR, WITH

POLYAMIDE NYLON 6.6 FIBER INSERT IN CHARCOAL COLOR.

B. FRAMING AND NOSING ACCESSORIES FOR VINYL FOOT GRILLE

1. SURFACE MOUNTED APPLICATION: 3/8" INCHES GRID AND

BEVELED, HEAVY-DUTY ATTACHED NOSING.

C. PRODUCT TESTING FOR VINYL FOOT GRILLE

1. ASTM C1028 STATIC COEFFICIENT OF FRICTION: WET, 1.01; DRY,

0.97

2.03 PRODUCT SUBSTITUTIONS

A. SUBSTITUTIONS: NO SUBSTITUTIONS PERMITTED.

PART 3 - EXECUTION

3.01 SUBSTRATE PREPARATION

A. EXAMINE SUBSTRATES AND CONDITIONS WHERE FLOOR MATS WILL

BE INSTALLED. DO NOT PROCEED WITH INSTALLATION UNTIL

UNSATISFACTORY CONDITIONS ARE CORRECTED. SUB FLOOR SHALL

BE CLEAN AND DRY, AND WITHIN ACCEPTABLE TOLERANCES.

3.02 INSTALLATION

A. SIZES: SHOP-FABRICATE UNITS OF FLOOR MAT TO GREATEST EXTENT

POSSIBLE IN SIZES AS INDICATED. WHERE NOT INDICATED

OTHERWISE, PROVIDE SINGLE UNIT FOR EACH MAT INSTALLATION,

BUT DO NOT EXCEED MANUFACTURER'S MAXIMUM SIZE

RECOMMENDATION FOR UNITS INTENDED FOR REMOVAL AND

CLEANING. WHERE JOINTS IN MATS ARE NECESSARY, SPACE

SYMMETRICALLY AND AWAY FROM NORMAL TRAFFIC LANES. MITER

CORNER JOINTS IN FRAMING ELEMENTS WITH HAIRLINE JOINTS OR

PROVIDE PREFABRICATED CORNER UNITS WITHOUT JOINTS. WHERE

POSSIBLE, VERIFY SIZES BY FIELD MEASUREMENT BEFORE SHOP

FABRICATION.

B. ACCESSORIES: FOR RECESSED, PROVIDE ALUMINUM FRAMEWORK AS

RECOMMENDED BY MANUFACTURER.

C. GENERAL: STRICTLY COMPLY WITH MANUFACTURER'S INSTALLATION

INSTRUCTIONS AND RECOMMENDATIONS. COORDINATE

INSTALLATION WITH ADJACENT WORK TO ENSURE PROPER

CLEARANCES AND TO PREVENT TRIPPING HAZARDS.

3.03 CLEANING AND PROTECTION

A. GENERAL CLEANING: REFER TO MANUFACTURER'S CLEANING AND

MAINTENANCE INSTRUCTIONS.

B. OWNER'S PERSONNEL: INSTRUCT OWNER'S PERSONNEL IN PROPER

MAINTENANCE PROCEDURES.

C. PROTECTION: PROTECT INSTALLED PRODUCT AND FINISH SURFACES

FROM DAMAGE DURING CONSTRUCTION AND UNTIL ACCEPTANCE.

END OF SECTION

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.7

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.7

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
4
Page 14: 2015-052 C1...Dec 04, 2015  · a6.0 interior elevations a6.1 interior elevations a7.0 wall sections a7.1 wall sections a8.0 details a8.1 details a9.0 door schedule and details a9.1

7

3 3A2

4

4

U.L. #U419

NOVEMBER 12, 2008

NONBEARING WALL RATINGS —

MIN. THICKNESS OF

INSULATION

(ITEM 3)

NO. OF LAYERS AND

THICKNESS OF PANELS

MIN.

STUD

DEPTH

RATING

2

3

U.L. #W-L-1001

1B

2

3

1A

A

A

SECTION A-A

June 15, 2005

F Ratings – 1, 2, 3 and 4 Hr (See Items 2 and 3)

T Ratings – 0, 1, 2, 3, and 4 Hr (See Item 3)

L Rating At Ambient – less than 1 CFM/sq ft

L Rating At 400 F – less than 1 CFM/sq ft

12 (305) 1 OR 2 0

1 (25)

4 (102)

6 (152)

1 (25)

3 OR 4

1 OR 2

3 OR 4

1 OR 2 0+, 1 OR 2

3 OR 4

0

0

MAX PIPE OR CONDUIT DIAM,

IN (mm).

F RATING, HR.T RATING,

HR.

APRIL 30, 1998

(FORMERLY SYSTEM NO. 328)

F RATINGS –

2

3

1B

2 3

1A

U.L. #W-L-1017

1C

SECTION A-A

A

A

1. FLOOR AND CEILING RUNNERS -- (NOT SHOWN) -- CHANNEL

SHAPED, FABRICATED FROM MIN 25 MSG

CORROSION-PROTECTED STEEL, MIN WIDTH TO ACCOMMODATE

STUD SIZE, WITH MIN 1 IN. LONG LEGS, ATTACHED TO FLOOR

AND CEILING WITH FASTENERS 24 IN. OC MAX.

2. STEEL STUDS -- CHANNEL SHAPED, FABRICATED FROM MIN 25

MSG CORROSION-PROTECTED STEEL, MIN WIDTH AS INDICATED

UNDER ITEM 4, MIN 1-1/4 IN. FLANGES AND 1/4 IN. RETURN,

SPACED A MAX OF 24 IN. OC. STUDS TO BE CUT 3/8 TO 3/4 IN.

LESS THAN ASSEMBLY HEIGHT.

3. BATTS AND BLANKETS* -- (REQUIRED AS INDICATED UNDER ITEM

4) -- MINERAL WOOL BATTS, FRICTION FITTED BETWEEN STUDS

AND RUNNERS. MIN NOM THICKNESS AS INDICATED UNDER ITEM

4. SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR

NAMES OF CLASSIFIED COMPANIES.

3A. BATTS AND BLANKETS* -- (OPTIONAL) -- PLACED IN STUD CAVITIES, ANY GLASS

FIBER OR MINERAL WOOL INSULATION BEARING THE UL CLASSIFICATION MARKING AS

TO SURFACE BURNING CHARACTERISTICS AND/OR FIRE RESISTANCE. SEE BATTS AND

BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES.

4. GYPSUM BOARD* -- GYPSUM PANELS WITH BEVELED, SQUARE

OR TAPERED EDGES, APPLIED VERTICALLY OR HORIZONTALLY.

VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED

ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. VERTICAL

JOINTS IN ADJACENT LAYERS (MULTILAYER SYSTEMS)

STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT

BE BACKED BY STEEL FRAMING. HORIZONTAL EDGE JOINTS AND

HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED

NOT BE STAGGERED. HORIZONTAL EDGE JOINTS AND

HORIZONTAL BUTT JOINTS IN ADJACENT LAYERS (MULTILAYER

SYSTEMS) STAGGERED A MIN OF 12 IN. THE THICKNESS AND

NUMBER OF LAYERS FOR THE 1 HR, 2 HR, 3 HR AND 4 HR

RATINGS ARE AS FOLLOWS:

WALLBOARD PROTECTION ON EACH SIDE OF WALL

1 3-1/2 1 LAYER, 5/8 IN. THICK OPTIONAL

1 2-1/2 1 LAYER, 3/4 IN. THICK 1-1/2 IN.

1 1-5/8 1 LAYER, 3/4 IN. THICK OPTIONAL

2 1-5/8 2 LAYER, 1/2 IN. THICK OPTIONAL

2 1-5/8 2 LAYER, 5/8 IN. THICK OPTIONAL

2 3-1/2 1 LAYER, 3/4 IN. THICK 3 IN.

3 1-5/8 3 LAYER, 1/2 IN. THICK OPTIONAL

3 1-5/8 3 LAYER, 3/4 IN. THICK OPTIONAL

3 1-5/8 3 LAYER, 5/8 IN. THICK OPTIONAL

4 1-5/8 4 LAYER, 5/8 IN. THICK OPTIONAL

4 1-5/8 4 LAYER, 1/2 IN. THICK OPTIONAL

4 2-1/2 2 LAYER, 3/4 IN. THICK 2 IN.

CANADIAN GYPSUM COMPANY -- 1/2 IN. THICK TYPE C, IP-X2 OR IPC-AR; WRC, 5/8 IN.

THICK TYPE AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX OR WRC; 3/4 IN. THICK

TYPE IP-X3, ULTRACODE, ULTRACODE SHC OR ULTRACODE WRC.

UNITED STATES GYPSUM CO -- 1/2 IN. THICK TYPE C, IP-X2, IPC-AR OR WRC; 5/8 IN.

THICK TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC, FRX-G, IP-AR, IP-X2, IPC-AR ; 3/4 IN.

THICK TYPE IP-X3, ULTRACODE, ULTRACODE SHC OR ULTRACODE WRC.

USG MEXICO S A DE C V -- 1/2 IN. THICK TYPE C, IP-X2, IPC-AR OR WRC; 5/8 IN. THICK

TYPE AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX, WRC OR; 3/4 IN. THICK TYPE

IP-X3, ULTRACODE, ULTRACODE SHC OR ULTRACODE WRC.

4A. GYPSUM BOARD* -- (AS AN ALTERNATE TO ITEM 4) -- 5/8 IN. THICK, 2 FT. WIDE,

TONGUE AND GROOVE EDGE, APPLIED HORIZONTALLY AS THE OUTER LAYER TO ONE

SIDE OF THE ASSEMBLY. SECURED AS DESCRIBED IN ITEM 5. JOINT COVERING (ITEM

7) NOT REQUIRED.

CANADIAN GYPSUM COMPANY -- TYPE SHX.

UNITED STATES GYPSUM CO -- TYPE SHX.

USG MEXICO S A DE C V -- TYPE SHX.

5. FASTENERS -- (NOT SHOWN) -- TYPE S OR S-12 STEEL SCREWS

USEDYER- 1-5/ TO ATTACH PANELS TO STUDS (ITEM 2) OR

FURRING CHANNELS (ITEM 6). SINGLE LAYER SYSTEMS: 1 IN.

LONG FOR 1/2 AND 5/8 IN. THICK PANELS OR 1-1/4 IN. LONG FOR

3/4 IN. THICK PANELS, SPACED 8 IN. OC WHEN PANELS ARE

APPLIED HORIZONTALLY, OR 8 IN. OC ALONG VERTICAL AND

BOTTOM EDGES AND 12 IN. OC IN THE FIELD WHEN PANELS ARE

APPLIED VERTICALLY. TWO LAYER SYSTEMS: FIRST LAYER- 1 IN.

LONG FOR 1/2 AND 5/8 IN. THICK PANELS OR 1-1/4 IN. LONG FOR

3/4 IN. THICK PANELS, SPACED 16 IN. OC. SECOND LAYER- 1-5/8

IN. LONG FOR 1/2 IN., 5/8 IN. THICK PANELS OR 2-1/4 IN. LONG

FOR 3/4 IN. THICK PANELS, SPACED 16 IN. OC WITH SCREWS

OFFSET 8 IN. FROM FIRST LAYER. THREE-LAYER SYSTEMS: FIRST

LAYER- 1 IN. LONG FOR 1/2 IN., 5/8 IN. THICK PANELS, SPACED 24

IN. OC. SECOND LAYER- 1-5/8 IN. LONG FOR 1/2 IN., 5/8 IN. THICK

PANELS, SPACED 24 IN. OC. THIRD LAYER- 2-1/4 IN. LONG FOR 1/2

IN., 5/8 IN. THICK PANELS OR 2-5/8 IN. LONG FOR 5/8 IN. THICK

PANELS, SPACED 12 IN. OC. SCREWS OFFSET MIN 6 IN. FROM

LAYER BELOW. FOUR-LAYER SYSTEMS: FIRST LAYER- 1 IN. LONG

FOR 1/2 IN., 5/8 IN. THICK PANELS, SPACED 24 IN. OC. SECOND

LAYER- 1-5/8 IN. LONG FOR 1/2 IN., 5/8 IN. THICK PANELS, SPACED

24 IN. OC. THIRD LAYER- 2-1/4 IN. LONG FOR 1/2 IN. THICK PANELS

OR 2-5/8 IN. LONG FOR 5/8 IN. THICK PANELS, SPACED 24 IN. OC.

FOURTH LAYER- 2-5/8 IN. LONG FOR 1/2 IN. THICK PANELS OR 3

IN. LONG FOR 5/8 IN. THICK PANELS, SPACED 12 IN. OC. SCREWS

OFFSET MIN 6 IN. FROM LAYER BELOW.

6. FURRING CHANNELS -- (OPTIONAL, NOT SHOWN, FOR SINGLE OR

DOUBLE LAYER SYSTEMS) -- RESILIENT FURRING CHANNELS

FABRICATED FROM MIN 25 MSG CORROSION-PROTECTED STEEL,

SPACED VERTICALLY A MAX OF 24 IN. OC. FLANGE PORTION

ATTACHED TO EACH INTERSECTING STUD WITH 1/2 IN. LONG

TYPE S-12 STEEL SCREWS. NOT FOR USE WITH ITEM 4A.

6A. STEEL FRAMING MEMBERS (NOT SHOWN)* -- (OPTIONAL ON ONE OR BOTH SIDES,

NOT SHOWN, FOR SINGLE OR DOUBLE LAYER SYSTEMS) -- AS AN ALTERNATE TO ITEM

6, FURRING CHANNELS AND STEEL FRAMING MEMBERS AS DESCRIBED BELOW:

A. FURRING CHANNELS -- FORMED OF NO. 25 MSG GALV STEEL. 2-3/8 IN.

WIDE BY 7/8 IN. DEEP, SPACED MAX. 24 IN. OC PERPENDICULAR TO

STUDS. CHANNELS SECURED TO STUDS AS DESCRIBED IN ITEM B.

GYPSUM BOARD ATTACHED TO FURRING CHANNELS AS DESCRIBED IN

ITEM 5. NOT FOR USE WITH ITEM 4A.

B. STEEL FRAMING MEMBERS* -- USED TO ATTACH FURRING CHANNELS

(ITEM 6A) TO STUDS (ITEM 2). CLIPS SPACED MAX. 48 IN. OC., AND

SECURED TO STUDS WITH NO. 8 X 1-1/2 IN. MINIMUM SELF-DRILLING,

S-12 STEEL SCREW THROUGH THE CENTER GROMMET. FURRING

CHANNELS ARE FRICTION FITTED INTO CLIPS.

PAC INTERNATIONAL INC -- TYPE RSIC-1.

7. JOINT TAPE AND COMPOUND -- VINYL OR CASEIN, DRY OR

PREMIXED JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS

AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOM 2 IN.

WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL

JOINTS OF OUTER LAYER PANELS. PAPER TAPE AND JOINT

COMPOUND MAY BE OMITTED WHEN GYPSUM PANELS ARE

SUPPLIED WITH A SQUARE EDGE.

8. SIDING, BRICK OR STUCCO -- (OPTIONAL, NOT SHOWN) --

ALUMINUM, VINYL OR STEEL SIDING, BRICK VENEER OR STUCCO,

MEETING THE REQUIREMENTS OF LOCAL CODE AGENCIES,

INSTALLED OVER GYPSUM PANELS. BRICK VENEER ATTACHED

TO STUDS WITH CORRUGATED METAL WALL TIES ATTACHED TO

EACH STUD WITH STEEL SCREWS, NOT MORE THAN EACH SIXTH

COURSE OF BRICK.

9. CAULKING AND SEALANTS* -- (OPTIONAL, NOT SHOWN) -- A BEAD

OF ACOUSTICAL SEALANT APPLIED AROUND THE PARTITION

PERIMETER FOR SOUND CONTROL.

UNITED STATES GYPSUM CO -- TYPE AS

*BEARING THE UL CLASSIFICATION MARK

1. WALL ASSEMBLY – THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM

WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED

OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE

INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS

IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE

THE FOLLOWING CONSTRUCTION FEATURES:

A. STUDS – WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX

2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD

STUDS TO CONSIST OF NOM. 2 BY 4 IN. (51 BY 102 MM) LUMBER

SPACED 16 IN. (406 MM) OC WITH NOM. 2 BY 4 IN. (51 BY 102 MM)

LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN

3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED

MAX 24 IN. (610 MM) OC.

B. GYPSUM BOARD* – NOM. 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122

CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM

WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE

AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL

U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE

DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM).

2. THROUGH PENETRANT – ONE METALLIC PIPE, CONDUIT OR

TUBING INSTALLED EITHER CONCENTRICALLY OR

ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR

SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF

OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO

MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY

SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE

FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS

OR TUBING MAY BE USED:

A. STEEL PIPE – NOM 24 IN. (610 MM) DIAM (OR SMALLER) SCHEDULE 10

(OR HEAVIER) STEEL PIPE.

B. IRON PIPE – NOM 24 IN. (610 MM) DIAM (OR SMALLER) SERVICE WEIGHT

(OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. (305 MM) DIAM (OR

SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE.

C. CONDUIT – NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR

NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC

TUBING

D. COPPER TUBING – NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR

HEAVIER) COPPER TUBING

E. COPPER PIPE – NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR

HEAVIER) COPPER PIPE.

F. THROUGH PENETRATING PRODUCT* – FLEXIBLE METAL PIPING – THE

FOLLOWING TYPES OF STEEL FLEXIBLE METAL GAS PIPING MAY BE

USED:

1. NOM 2 IN. (51 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS

PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH

SIDES OF FLOOR OR WALL ASSEMBLY.

OMEGA FLEX INC

2. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS

PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH

SIDES OF FLOOR OR WALL ASSEMBLY.

TITEFLEX CORP

A BUNDY CO

3. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS

PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH

SIDES OF FLOOR OR WALL ASSEMBLY.

WARD MFG INC

3. FILL, VOID OR CAVITY MATERIAL* – CAULK OR SEALANT – MIN 5/8.

1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF

CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY,

APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF

WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO

GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT

LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF

THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE

RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS

SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF

THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE

OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF

THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED

BELOW:

+WHEN COPPER PIPE IS USED, T RATING IS 0 HR.

3M COMPANY – CP 25WB+ CAULK OR FB-3000 WT SEALANT,

*BEARING THE UL CLASSIFICATION MARKING

1. WALL ASSEMBLY – THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL

ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER

DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN

THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING

CONSTRUCTION FEATURES:

A. STUDS – WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS.

WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN.

LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE BY 1-3/8 IN.

DEEP CHANNELS SPACED MAX 24 IN. OC.

B. GYPSUM BOARD* – NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE

GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS AND SHEET ORIENTATION SHALL BE AS

SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF CIRCULAR THROUGH

OPENING CUT THROUGH GYPSUM WALLBOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN

0 IN. (POINT CONTACT) TO MAX 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL

CONDUIT (ITEM 2) INSTALLED IN THROUGH OPENING. SIDE EDGE OF CIRCULAR OPENING TO

BE MIN 3 IN. FROM NEAREST STUD IN WALL CAVITY.

C. FASTENERS – WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED

TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION

DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD

ATTACHED TO STUDS WITH TYPE S SELF-DRILLING, SELF-TAPPING BUGLE-HEAD STEEL

SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN.

2. THROUGH PENETRATING PRODUCT* – FLEXIBLE METAL CONDUIT – NOM 4 IN. DIAM (OR

SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX ONE FLEXIBLE

METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM

WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES

OF WALL ASSEMBLY. AFC CABLE SYSTEMS INC

3. FILL, VOID OR CAVITY MATERIAL* – CAULK – CAULK FILL MATERIAL FORCED INTO

ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING

PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH

SIDE OF THE WALL ASSEMBLY. A MIN 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR

THE 1 HR F RATING. A MIN 1-1/4 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 2 HR F

RATING.

3M COMPANY – CP 25WB+

*BEARING THE UL CLASSIFICATION MARKING

1 2 3 5

B

A

JOB NO.

D

C

ISSUED FOR:

PERMIT

RELEASE

CONSTRUCTION

BID

2015-052

PE

T S

UP

PLIE

S P

LU

S

FO

OT

HILLS

P

LA

ZA

541 F

OO

TH

ILLS

P

LA

ZA

D

R.

-

-

12.04.15

-

MA

RY

VILLE

, T

N 37801

RE

V.

DA

TE

DE

SC

RIP

TIO

N

DESIGNERPROJECT MANAGER

Dra

win

g N

am

e: X

:\2

01

5.0

52

P

SP

- M

aryville

, T

N (fra

nch

ise

e)\C

AD

\2

01

5.0

52

_A

S1

.8

.d

wg

De

ce

mb

er 4

, 2

01

5 - w

alb

re

ch

t

AS1.8

AR

CH

IT

EC

TU

RA

L

SP

EC

IF

IC

AT

IO

NS

SBE SBE

AutoCAD SHX Text
1, 2, 3 OR 4 HR (SEE ITEMS 4 & 5)
AutoCAD SHX Text
1 AND 2 HR. (SEE ITEM 3) T RATING – 0 HR 0 HR L RATING AT AMBIENT – LESS THAN 1 CFM/SQ FT LESS THAN 1 CFM/SQ FT L RATING AT 400 F – LESS THAN 1 CFM/SQ FTLESS THAN 1 CFM/SQ FT
AutoCAD SHX Text
4