CONSULTANTS
AREA MAP VICINITY MAP
G-2 DRIVEWAY PLAN
G-1 GRADING TITLE SHEET
SHEET INDEX
SIDE SETBACK
REAR SETBACK
FRONT SETBACK
ZONING
LOT AREA
A.P.N.
30'
30'
30'
HS-D1
1.00 Ac. (43,560 SQUARE FEET)
612-37-016
BUILDING SITE APPROVAL/
PREPARED FOR:
PROPERTY LOCATION:
SAN JOSE, CALIFORNIA 95127
MAXIMUM NUMBER OF STORIES 2
COVER SHEET/
INDEX
MAXIMUM HEIGHT 35'
G-3
PROPOSED LIVING AREA 4,450 SQUARE FEET
CONSTRUCTION TYPE VN
SITE INFORMATION
GEOTECHNICAL ENGINEER
ASSOCIATED TERRA CONSULTANTS, INC.
1735 DELL AVENUE
CAMPBELL, CALIFORNIA 94030
RICK HALTENHOFF
CIVIL ENGINEER
STEVEN ARNOLD CIVIL ENGINEERING, INC.
492 PRINCE STREET
OAKLAND, CALIFORNIA 94610
ANDREW E. ARNOLD, P.E.
VINOD AND JANAK BANSAL
3522 ADEGA CIRCLE
SAN JOSE, CALIFORNIA 95148
PHONE
OWNERS
PHONE
PHONE
PROPOSED F.A.R. 4450/43560 x 100 = 10.2%
GRADING AND DRAINAGE PLAN/
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
VINOD AND JANAK BANSAL
11391 CLAYTON ROAD
SITESITE
G-5 GRADING DETAILS
SEPTIC SYSTEM PLAN
C1 COVER SHEET/INDEX
GRADING AND DRAINAGE PLAN/
SEPTIC SYSTEM PLAN
(650) 533-9484
(408) 866-1067
(415) 786-9622
FAX (415) 871-2582
EMAIL [email protected]
FAX (408) 866-1047
GRADING SECTIONSG-4
PROJECT DESCRIPTION
NUMBER OF BEDROOMS 3
JONATHAN COULTER
930 SAN BENITO STREET
HOLLISTER, CALIFORNIA 95023
PHONE
ARCHITECTURAL DRAFTING/DESIGNER
(831) 537-4040
A1 MAIN FLOOR PLAN
A2 LOWER FLOOR PLAN
A3 ROOF PLAN
A4 EXTERIOR ELEVATIONS
A5 EXTERIOR ELEVATIONS
A6 CROSS SECTION
G-6 GRADING DETAILS
C1
- NEW DRIVEWAY AND TURNAROUND WILL BE CONSTRUCTED
AS SHOWN FOR ACCESS.
- NEW SEPTIC SYSTEM AND LEACH FIELD WILL BE INSTALLED
AS SHOWN.
- NEW SINGLE FAMILY RESIDENTIAL CUSTOM HOME OF UP TO
MAX. 3 BEDROOMS AND A MAXIMUM OF 4,450 SQUARE FEET
OF LIVING SPACE WILL BE CONSTRUCTED AS SHOWN.
- DRAINAGE IMPROVEMENTS AND UTILITIES WILL BE
INSTALLED AS SHOWN.
- NEW ROADWAY IMPROVEMENTS ARE PROPOSED FOR THE
PRIVATE ACCESS ROAD FROM CLAYTON ROAD UP TO THE 45'
EASEMENT EXTENSION.
A0 SITE PLAN
L-1 LANDSCAPE PLAN
GRADING SECTIONSG-4.1
N
134'-3 5/8"
31
'-1
"
30
'-0
"
40'-0"
WALK (PAVERS)
WA
LK
(P
AV
ER
S)
N 04° 59' 11" W 240.00'
N 04° 59' 11" W 240.00'
N 8
5°
00' 49"
E
181.5
0'
N 8
5°
00' 49"
E
181.5
0'
5' MAX HT. RETAINING WALL SHALL BE
TREATED WITH A BLEND OF
EARTH TONE COLOR AND
SCREENING TREES
5' MAX HT. RETAINING WALL SHALL BE
TREATED WITH A BLEND OF
EARTH TONE COLOR AND
SCREENING TREES
DRIVEWAY
SCALE: 1"=10'
WALK (PAVERS)
5' RETAINING WALL SHALL BE
TREATED WITH A BLEND OF
EARTH TONE COLOR AND
SCREENING TREES
Site Plan
CL
AY
TO
N
R
OA
D
PROPERTY LINE TYPICALPROPERTY CORNER
PROPOSED HOME
SHEET
SCALE
DATE
PL
AN
FO
R:
PL
AN
BY
:
Jo
nath
an
C
ou
lter
930 S
an
Ben
ito
Str
eet
Ho
llis
ter,
Ca. 95023
Ph
on
e:
(831)
637-8
059 (8
31)
537-4
040
MR
& M
RS
BA
NS
AL
11391 C
LA
YT
ON
RO
AD
SA
N J
OS
E,
CA
. 95127 (
650)
533-9
484
A0
N
5' MAX HT.RETAINING WALL SHALL BETREATED WITH A BLEND OF
EARTH TONE COLOR AND SCREENING TREES
DRIVEWAY
NO
TR
EES A
LLO
WED
IN
LEA
CH
FIE
LD
SCALE: 1"=10'
WALK (PAVERS)
5' RETAINING WALL SHALL BETREATED WITH A BLEND OF
EARTH TONE COLOR AND SCREENING TREES
5' MAX HT.RETAINING WALL SHALL BETREATED WITH A BLEND OF
EARTH TONE COLOR AND SCREENING TREES
LEGEND
= 24" BOX FRUIT TREE PER COUNTY STANDARDS
= 24" BOX EVERGREEN PER COUNTY STANDARDS
= LARGE DROUGHT TOLERANT SHRUB
PER COUNTY STANDARDS
= MEDIUM DROUGHT TOLERANT SHRUB PER COUNTY STANDARDS
= SMALL DROUGHT TOLERANT SHRUB
PER COUNTY STANDARDS
Landscaping Plan
CL
AY
TO
N
R
OA
D
PROPERTY LINE TYPICALPROPERTY CORNER
PROPOSED HOME
SHEET
SCALE
DATE
PL
AN
FO
R:
PL
AN
BY
:
Jo
nath
an
C
ou
lter
930 S
an
Ben
ito
Str
eet
Ho
llis
ter,
Ca. 95023
Ph
on
e:
(831)
637-8
059 (8
31)
537-4
040
MR
& M
RS
BA
NS
AL
11391 C
LA
YT
ON
RO
AD
SA
N J
OS
E,
CA
. 95127 (
650)
533-9
484
L-1
GRADING
5.
4.
2.
3.
1.
1.
6.
5.
OF SANTA CLARA STANDARD SPECIFICATIONS; 4) STATE OF CALIFORNIA STANDARD DETAILS;
5) STATE OF CALIFORNIA STANDARD SPECIFICATIONS.
DEVELOPER SHALL OBTAIN ENCROACHMENT PERMITS FROM THE SANTA CLARA VALLEY WATER
PERFORMANCE AND COMPLETION OF ALL WORK MUST BE TO THE SATISFACTION OF THE COUNTY.
IN THE EVENT OF CONFLICT THE FORMER SHALL TAKE PRECEDENCE OVER THE LATTER. THE
COMPLY WITH COUNTY STANDARDS OR CONDITIONS OF DEVELOPMENT APPROVAL.
WORK AND SUCH CORRECTION AND MODIFICATION OF PLANS AS MAY BE NECESSARY TO
THESE PLANS. THE COUNTY SHALL BE AUTHORIZED TO REQUIRE DISCONTINUANCE OF ANY
DEVELOPER SHALL BE RESPONSIBLE FOR CORRECTION OF ANY ERRORS OR OMISSIONS IN
PLANS AND HE OR HIS SUCCESSOR PROPERTY OWNERS ARE RESPONSIBLE FOR THEIR
DEVELOPER IS RESPONSIBLE FOR INSTALLATION OF THE IMPROVEMENTS SHOWN ON THESE
4.
CONTINUED MAINTENANCE.
2.
COUNTY OF SANTA CLARAGENERAL CONSTRUCTION
1) THESE PLANS AND SPECIFICATIONS; 2) THE COUNTY OF SANTA CLARA STANDARD DETAILS; 3) THE COUNTY
REPORT PREPARED BY ASSOCIATED TERRA CONSULTANTS, INC. FILE NO. 178831 DATED SEPTEMBER 11, 2002.
ALL CONSTRUCTION WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SOILS AND/OR GEOTECHNICAL
SPECIFICATIONS
2. ALL EXPOSED DISTURBED AREAS SHALL BE SEEDED WITH BROME SEED SPREAD AT THE RATE
RUN-OFF SHALL BE RELEASED TO SHEET FLOW.
OF 5 POUNDS PER 1000 SQUARE FEET (OR APPROVED EQUAL). SEEDING AND WATERING SHALL BE
AT ALL DITCH OUTFALLS. WHERE OUTFALLS ARE NOT INTO AN EXISTING CREEK OR WATER COURSE,
EROSION CONTROLS, e.g. SACKED CONCRETE RIP-RAP. ENERGY DISSIPATORS SHALL BE INSTALLED
ALL STORM DRAINAGE STRUCTURES SHALL BE INSTALLED WITH EFFECTIVE ENTRANCE AND OUTFALL
DRIVEWAY LOCATIONS SHALL BE AS SHOWN ON THE IMPROVEMENT PLANS WITH CENTERLINE
STATIONING. THE MINIMUM CONCRETE THICKNESS SHALL BE 6 INCHES THROUGHOUT. THE MAXIMUM
APPROACH GRADE SHALL BE 5% FOR A LENGTH OF 20 FEET.
ALL DITCHES AT SLOPES GREATER THAN 5% SHALL BE LINED WITH 2" AC OR PCC THROUGHOUT.
1.
DRIVEWAYS
MAINTAINED AS REQUIRED TO ENSURE GROWTH.
3.
4.
ALL FILL SLOPES SHALL BE COMPACTED AND LEFT IN A SMOOTH AND FIRM CONDITION CAPABLE
EROSION CONTROL
OF WITHSTANDING WEATHERING.
1.
VICINITY MAP
COUNTY LOCATION MAP
1.
PACIFIC GAS & ELECTRIC ELECTROLIER SERVICE FEE SHALL BE PAID BY THE DEVELOPER AND/OR
CONSTRUCTION STAKING
STABILIZED, ETC. FOR THE CONVENIENCE OF CONTRACTORS. LATERAL OFFSET OF STAKES SET
OF CONSTRUCTION GRADE STAKES. THE STAKES ARE TO BE ADEQUATELY IDENTIFIED, LOCATED,
THE DEVELOPER'S ENGINEER IS RESPONSIBLE FOR THE INITIAL PLACEMENT AND REPLACEMENT
SHALL BE REPLACED BY DEVELOPER'S ENGINEER OR LICENSED LAND SURVEYOR.
ANY PROPERTY LINE STAKES OR ROAD MONUMENTS DISTURBED DURING CONSTRUCTION
FOR CURBS AND GUTTERS SHALL NOT EXCEED 2 1/2 FEET FROM THE BACK OF CURB.
CONSTRUCTION INSPECTION
2.
1.
DEVELOPER SHALL REMOVE OR TRIM ALL TREES TO PROVIDE AN UNOBSTRUCTED FIFTEEN
OFFICE IN ACCORD WITH PROVISIONS OF THIS ORDINANCE. (COUNTY ORDINANCE CODE SECTION B6-18).
NO FURTHER DISTURBANCE OF THE SITE MAY BE MADE EXCEPT AS AUTHORIZED BY THE LAND DEVELOPMENT
OR ARTIFACTS, THE PERSON MAKING SUCH DISCOVERY SHALL IMMEDIATELY NOTIFY THE COUNTY
UPON DISCOVERING OR UNEARTHING ANY BURIAL SITE AS EVIDENCE BY HUMAN SKELETAL REMAINS
CORONER AT (408) 454-2520 AND LAND DEVELOPMENT ENGINEERING OFFICE AT (408) 299-5730
SECTION 13005 OF THE HEALTH AND SAFETY CODE RELATING TO THE USE OF SPARK
ALL PERSONS MUST COMPLY WITH SECTION 4442 OF THE PUBLIC RESOURCES CODE AND
DEVELOPER SHALL PROVIDE ADEQUATE DUST CONTROL AS REQUIRED BY THE COUNTY
(15) FOOT VERTICAL CLEARANCE FOR ROADWAY AREA.
ARRESTERS.
9.
INSPECTOR.
8.
5.
7.
ALL MATERIALS AND METHODS OF CONSTRUCTION OF SANITARY SEWERS SHALL CONFORM TO
THE SPECIFICATIONS OF THE JURISDICTION INVOLVED. INSPECTION OF SANITARY SEWER WORK
DESIGN SHALL BE UNDER THE CONTINUAL CONTROL OF THE COUNTY INSPECTOR.
MINIMUM STRENGTH FACTOR OF 2200 P.S.I. IN A SEVEN DAY PERIOD. THE CONCRETE MIX
CONCRETE USED FOR STRUCTURAL PURPOSES SHALL BE CLASS "A" (6 SACK PER CUBIC YARD) AS
SPECIFIED IN THE STATE STANDARD SPECIFICATIONS. CONCRETE PLACED MUST DEVELOP A
SANITARY SEWERS
PORTLAND CEMENT CONCRETE
SHALL BE DONE BY SAID JURISDICTION.
1.
1.
UPON INSTALLATION OF DRIVEWAY CONNECTIONS, PROPERTY OWNERS SHALL PROVIDE FOR THE
FOR THE ADEQUACY AND CONTINUED MAINTENANCE OF THESE FACILITIES IN A MANNER WHICH
DROP INLETS SHALL BE COUNTY STANDARD TYPE 5 UNLESS OTHERWISE NOTED ON THE PLANS
WHERE CULVERTS ARE INSTALLED THE DEVELOPER SHALL BE RESPONSIBLE FOR GRADING THE OUTLET
INLETS. WHERE STREET PROFILE GRADE EXCEEDS 6% DROP INLETS SHALL BE SET AT 30 DEGREE ANGLE
UNINTERRUPTED FLOW OF WATER IN ROADSIDE DITCHES.
DITCH TO DRAIN TO AN EXISTING SWALE OR TO AN OPEN AREA OF SHEET FLOW.
DEVELOPER IS RESPONSIBLE FOR ALL NECESSARY DRAINAGE FACILITIES WHETHER SHOWN
ON THE PLANS OR NOT AND HE OR HIS SUCCESSOR PROPERTY OWNERS ARE RESPONSIBLE
WILL PRECLUDE ANY HAZARD TO LIFE, HEALTH OR DAMAGE TO ADJOINING PROPERTY.
THE DEVELOPER'S ENGINEER SHALL BE RESPONSIBLE FOR THE PROPER LOCATION OF DROP
CURB LINE TO ACCEPT WATER OR AS SHOWN ON THE PLANS.
2.
3.
4.
HIS AUTHORIZED REPRESENTATIVE
STORM DRAINAGE
1.
DISTRICT AND CALIFORNIA DEPARTMENT OF TRANSPORTATION WHERE NEEDED. COPIES OF THESE
PERMITS SHALL BE KEPT AT THE JOB SITE FOR REVIEW BY THE COUNTY'S INSPECTOR.
STREET LIGHTING
WITH THE APPLICABLE PROVISIONS OF THE STATE SPECIFICATIONS. THE STRUCTURAL SECTION
AGGREGATE BASE MATERIAL, COMPACTED TO A RELATIVE COMPACTION OF AT LEAST 95%, AND 4
FOR TRENCH REPLACEMENT SHALL CONSIST OF NOT LESS THAN 12 INCHES OF APPROVED
STATEMENT OF PURPOSE
3.INSPECTION BY SANTA CLARA COUNTY SHALL BE LIMITED TO INSPECTION OF MATERIALS AND
EQUIPMENT OR PERSONNEL. CONTRACTOR SHALL NOTIFY THE COUNTY LAND DEVELOPMENT INSPECTOR AT
ROADWAYS (EITHER PRIVATE OR TO BE DEDICATED TO PUBLIC USE).
APPROXIMATE AND FOR GENERAL INFORMATION ONLY.
OTHER OBSTRUCTIONS IN THE WAY OF CONSTRUCTION.
COMPACTED BEFORE PLACING AGGREGATE BASE MATERIAL OR SURFACE STRUCTURES. SURFACING
OR FACILITIES SHALL BE THE INDIVIDUAL CONTRACTORS RESPONSIBILITY. PLAN LOCATIONS ARE
ACCURATE VERIFICATION AS TO SIZE, LOCATION AND DEPTH OF EXISTING UNDERGROUND CONDUITS
BORE. UNLESS SPECIFICALLY AUTHORIZED BY THE COUNTY, GAS AND WATER MAINS SHALL BE
TRENCH BACKFILL IN EXISTING PAVEMENT AREAS SHALL BE SAND MATERIAL IN ACCORDANCE.
IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO MOVE OR RELOCATE UTILITY POLES AND
b) FROM AREAS AFFECTED BY THE PROPOSED GRADING EXCEPT WHERE NOTED ON THE PLANS.
ALL UNDERGROUND INSTALLATIONS SHALL BE IN PLACE AND THE TRENCH BACKFILLED AND
MAY BE DONE IF THE UTILITY COMPANY CONCERNED INDICATES BY LETTER THAT IT WILL
INSTALLED OUTSIDE THE PAVED AREA.
4.
3.
2.
2.
DOES NOT INCLUDE RESPONSIBILITY FOR THE SUPERINTENDENCE OF CONSTRUCTION, SITE CONDITIONS,
PROCESSES, OF CONSTRUCTION TO OBSERVE THEIR COMPLIANCE WITH PLANS AND SPECIFICATIONS, BUT
DEVELOPER AND/OR HIS AUTHORIZED REPRESENTATIVE MUST SUBMIT WRITTEN REQUEST FOR
FINAL INSPECTION AND ACCEPTANCE. SAID REQUESTS SHALL BE DIRECTED TO THE INSPECTION
PHONE (408) 299-6868 AT LEAST 24 HOURS PRIOR TO COMMENCING WORK AND FOR FINAL INSPECTION
IMPROVED TO AN AUTHORIZED DISPOSAL SITE AS FOLLOWS:
EXISTING TREES, ROOTS AND FOREIGN MATERIAL WILL BE REMOVED FROM AREAS TO BE
a) TO A MINIMUM DEPTH OF TWO FEET BELOW THE FINISHED GRADE PROPOSED
OFFICE NOTED ON THE PERMIT FORM.
SITE PREPARATION (CLEARING & GRUBBING)
1.
OF WORK AND SITE.
4.
HOURS FOR ASPHALT CONCRETE INSPECTION.
CONTRACTOR SHALL NOTIFY PERMIT INSPECTION UNIT, SANTA CLARA COUNTY PRIOR TO COMMENCING
THE COUNTY REQUIRES A MINIMUM 24 HOUR ADVANCE NOTICE FOR GENERAL INSPECTION, 48
WORK AND FOR FINAL INSPECTION OF WORK AND SITE.
2.
1.
THE WESTERLY PROPERTY LINE OF PARCEL.
GINNIE NO. 1 APPROXIMATELY 2 FEET FROM THE SOUTH EDGE OF CLAYTON ROAD NEAR
BENCHMARK
BE COMPACTED TO 95% OF MAXIMUM DENSITY.
NO ORGANIC MATERIAL SHALL BE PLACED IN ANY FILL NO TREES SHALL BE REMOVED OUTSIDE
SURPLUS EARTH FILL MATERIAL SHALL BE PLACED IN A SINGLE (8" max) THICK LAYER COMPACTED
MAXIMUM CUT SLOPE SHALL BE 1 1/2 HORIZONTAL TO 1 VERTICAL. MAXIMUM FILL SLOPE SHALL BE
2 HORIZONTAL TO 1 VERTICAL.
TO WITHSTAND WEATHERING IN THE AREA(S) DELINEATED ON THE PLAN.
THE UPPER 6" OF SUBGRADE BELOW DRIVEWAY, ACCESS ROAD, OR PARKING AREA SHALL
OF CUT, FILL, OR ROADWAY AREAS.
MAXIMUM DEPTH OF CUT
CONSTRUCTION/ENCROACHMENT/GRADING PERMIT
COUNTY OF SANTA CLARA
LAND DEVELOPMENT ENGINEERING & SURVEYING
ENVIRONMENTAL RESOURCES AGENCY
ISSUED BY:
PERMIT(S) NO. :
FILE'(S) NO.:
DATE:
INADEQUATE COMPARED TO THE PROPOSED TYPICAL PAVEMENT SECTION, SHALL BE
WATER CONTENT THAT WILL PERMIT PROPER COMPACTION BY EITHER: (1) AERATING THE FILL IF
BE THOROUGHLY MIXED BEFORE COMPACTION TO ENSURE A UNIFORM DISTRIBUTION OF MOISTURE.
IT IS TOO WET, OR (2) MOISTENING THE FILL WITH WATER IF IT IS TOO DRY. EACH LIFT SHALL
IS PLACED. WHERE NATURAL GROUND IS STEEPER THAN 5:1, IT SHALL BE BENCHED AND THE
EXISTING FILL SHALL BE REMOVED UNTIL MATERIAL COMPACTED TO 90% RELATIVE COMPACTION
IS EXPOSED. THEN THE NEW FILL MATERIAL SHALL BE PLACED IN UNIFORM LIFTS NOT EXCEEDING
MATERIAL, THE SURFACE OF THE GROUND SHALL BE SCARIFIED TO DEPTH OF 6" BEFORE FILL
REMOVED, RECONSTRUCTED OR REPLACED AS REQUIRED BY THE COUNTY INSPECTOR IN THE FIELD.
HAULED AWAY FROM THE SITE. WHERE FILL MATERIAL IS TO BE PLACED ON NATURAL GROUND,
6" OF UNCOMPACTED THICKNESS BEFORE COMPACTION BEGINS, THE FILL SHALL BE BROUGHT TO A
EXCAVATED MATERIAL SHALL BE PLACED IN THE FILL AREAS DESIGNATED OR SHALL BE
IT SHALL BE STRIPPED OF ALL VEGETATION. TO ACHIEVE A PROPER BOND WITH THE FILL
GRADING
THE CONSTRUCTION OPERATIONS AND ANY EXISTING SHOULDER AREAS WHICH ARE STRUCTURALLY
TRENCH BACKFILL IN NEW CONSTRUCTION AREAS SHALL BE SAND MATERIAL COMPACTED TO
MAY BE WAIVED BY COUNTY IF THE NATIVE SOIL IS SUITABLE FOR USE AS TRENCH BACKFILL,
BACKFILL AND TRENCH RESTORATION REQUIREMENTS SHALL APPLY AS MINIMUM STANDARDS
INCHES OF HOT ASPHALT CONCRETE PLACED IN TWO LIFTS. TRENCH RESTORATION FOR HIGHER
ANY EXISTING IMPROVEMENTS WHICH ARE SCARRED, DAMAGED, OR REMOVED DURING
A RELATIVE COMPACTION OF AT LEAST 90%. THE REQUIREMENT FOR SELECT MATERIAL
BUT THE COMPACTION REQUIREMENTS WILL NOT BE THEREBY WAIVED.
TO ALL UNDERGROUND FACILITIES INSTALLED BY OTHER FIRMS OR PUBLIC AGENCIES.
TYPE PAVEMENTS SHALL BE MADE IN KIND OR AS DIRECTED BY THE COUNTY.
REPLACEMENT OF DAMAGED IMPROVEMENTS
3. INSTALL ROAD AND DRIVEWAY FOR ACCESS AS SHOWN.
1. CLEAR AND GRUB.
2. COMPLETE GRADING FOR INSTALLATION OF PROPOSED RESIDENCE AND DRIVEWAY.
ENGINEER'S STATEMENT
DATED
COUNTY ENGINEER'S NOTE
OR THE PLANS, THE COUNTY SHALL HAVE THE AUTHORITY TO REQUIRE THE
SPECIFY THE MANNER IN WHICH THE SAME IS TO BE MADE.
APPROVED TENTATIVE MAP (OR PLAN) AND CONDITIONS OF APPROVAL PERTAINING THERETO
I HEREBY STATE THAT THESE PLANS ARE IN COMPLIANCE WITH ADOPTED COUNTY STANDARDS, THE
OMISSIONS CONTAINED IN THE PLANS, IF, DURING THE COURSE OF THE CONSTRUCTION, THE
PERMITTEE OR ENGINEER FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS OR
ISSUANCE OF A PERMIT AUTHORIZING CONSTRUCTION DOES NOT RELEASE THE DEVELOPER,
SUSPENSION OF WORK, AND THE NECESSARY MODIFICATION OR DEPARTURE AND TO
PUBLIC INTEREST REQUIRES A MODIFICATION OF (OR A DEPARTURE FROM) THE SPECIFICATIONS
DATE
DATE
SIGNATURER.C.E. No. / EXPIRATION DATE
CUBIC YARDS
MAXIMUM DEPTH OF FILL
CUBIC YARDS
FEET
FEET
ESTIMATED VOLUME OF CUT
ESTIMATED VOLUME OF FILL
3.
1.
PURPOSE OF GRADING AND DRAINAGE PLAN ILLUSTRATES PROPOSED
SINGLE FAMILY CUSTOM HOME AND THE REQUIRED GRADING.
SCOPE OF WORK
ELEVATION = 100.00'
SPECIFICATIONS; 2) THE COUNTY OF SANTA CLARA STANDARD DETAILS; 3) THE COUNTY
THESE REPORTS ARE SUPPLEMENTED BY:
APPROXIMATE EARTHWORK QUANTITIES
DESCRIPTION CUT FILL
ON SITE DRIVEWAY
OFF SITE DRIVEWAY AND TURNAROUND
THIS PLAN AUTHORIZES THE REMOVAL OF ONLY THOSE TREES WITH TRUNK DIAMETERS GREATER6.
THAN 12 INCHES MEASURED 4.5 FEET ABOVE THE GROUND THAT ARE SHOWN TO BE REMOVED
UNLESS AN AMENDED PLAN IS APPROVED OR A SEPARATE TREE REMOVAL PERMIT IS OBTAINED
FROM THE PLANNING OFFICE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT REMOVAL
OF ADDITIONAL TREES HAS BEEN PERMITTED.
24 HOURS BEFORE FEGINNING UNDERGROUND WORK FOR VERIFICATION OF THE LOCATION OF
CONTRACTOR SHALL NOTIFY USA (UNDERGROUND SERVICE ALERT) AT 800-227-2600 A MINIMUM
UNDERGROUND UTILITIES.
UTILITY LOCATION, TRENCHING & BACKFILL
1.
-IMPORTED MATERIALS
EXCESS MATERIALS
CUBIC YARDS
CUBIC YARDS
ALL EXCESS GRADING MATERIALS SHALL BE DISPOSED AT A COUNTY APPROVED DUMP SITE.6.
, FILE(S) No.
R.C.E. No. / EXPIRATION DATESIGNATURE
AS-BUILT PLAN STATEMENT
THIS IS A TRUE COPY OF THE AS-BUILT PLANS. THERE ( WERE) ( WERE NOT)
MINOR FIELD CHANGES--MARKED WITH . THERE ( WERE) ( WERE NOT)
PLAN REVISIONS INDICATING SIGNIFICANT CHANGES REVIEWED BY THE COUNTY ENGINEER
AND MARKED WITH THE SYMBOL .
DATE
SIGNATURE
NOTE: THIS STATEMENT IS TO BE SIGNED BY THE PERSON AUTHORIZED BY THE COUNTY
ENGINEER TO PERFORM THE INSPECTION WORK. A REPRODUCIBLE COPY OF THE AS-BUILT
PLANS MUST BE FURNISHED TO THE COUNTY ENGINEER AFTER CONSTRUCTION.
BEARINGS SHOWN ON THIS MAP.
SANTA CLARA, STATE OF CALIFORNIA WAS TAKEN AS THE BASIS OF
THE BEARING N 85° 00' 49" E OF THE CENTERLINE OF CLAYTON ROAD
IN THE OFFICE OF THE COUNTY RECORDER OF THE COUNTY OF
AS SHOWN ON THE PARCEL MAP BOOK 644 OF MAPS AT PAGE 24
BASIS OF BEARING
NAME
NAME
ANDREW E. ARNOLD
CHRISTOPHER L. FREITAS
RCE 66537 EXP. 06/30/2016
RCE 42107 EXP. 03/31/2016
NOTES:
THE WATER AND SANITARY UTILITIES SHOWN ON THESE PLANS ARE SHOWN
1.
FOR REFERENCE ONLY.
SHALL BE RESEEDED IN CONFORMANCE WITH THE COUNTY GRADING ORDINANCE
PRIOR TO GRADING COMPLETION AND RELEASE OF BOND, ALL GRADED AREAS
2.
TO MINIMIZE THE VISUAL IMPACTS OF THE GRADED SLOPES AND REDUCE THE
POTENTIAL FOR EROSION ON THE SUBJECT SITE.
ROADWAYS DESIGNATED AS NOT COUNTY MAINTAINED ROADS AS SHOWN UPON
3.
THIS PLAN WILL NOT BE ELIGIBLE FOR COUNTY MAINTENANCE UNTIL THE ROADWAYS
ARE IMPROVED (AT NO COST TO THE COUNTY) TO PUBLIC MAINTENANCE ROAD
STANDARDS APPROVED BY THE BOARD OF SUPERVISORS AND IN EFFECT AT SUCH TIME
THAT THE ROADWAYS ARE CONSIDERED FOR ACCEPTANCE INTO THE COUNTY'S ROAD SYSTEM.
4. A CONSTRUCTION OBSERVATION LETTER FROM THE RESPONSIBLE GEOTECHNICAL ENGINEER
DETAILING CONSTRUCTION OBSERVATIONS AND CERTIFYING THAT THE WORK WAS DONE IN
ACCORDANCE WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT SHALL BE SUBMITTED
PRIOR TO GRADING COMPLETION AND RELEASE OF BOND.
COUNTY OF SANTA CLARA
Development Services Office
Land Development Engineering Division
Construction Permit No.:
Issued by: Date:
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
TITLE SHEET
SITE
SITE
LANDSCAPE AND COURTYARD
GRADING IN EASEMENT OFF SITE
BUILDING PAD
0 cu. yd.800 cu. yd.
0 cu. yd.335 cu. yd.
0 cu. yd.550 cu. yd.
130 cu. yd.200 cu. yd.
210 cu. yd.90 cu. yd.
2025
390
1635
10
10
PRO RATA SHARE OF PRIVATE ROAD 50 cu. yd.50 cu. yd.
G-1
DRIVEWAY PLAN
DRIVEWAY PLAN
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
N 85°00'49" E 181.50'
N 04°59'11" W
240.
00'
N 85°00'49" E
PROPOSED
N 04°59'11" W
240.
00'
N 85°00'49" E 181.50'
S 29°46'29" W
S 19°52'04" W
S 06°16'49" W
S 10°30'38" E
N 37°00'38" W
N 40°13'48" W
N 32°34'37" W
89.5
3'
72.7
7'
78.1
3'
87.57'
210.28'
261.85'
141.65'
N 85°00'49" E 180.97'N 85°00'49" E 119.90'N 84°49'19" E 127.81'N 85°22'39" E 176.25'
N 85°00'49" E 275.57'
S 47°48'31" E
23.90'48.60'
S 66°03'1
8" W
476.15'
S 03°15'00" W
672.
58'
N 84°49'19" EN 85°22'39" E
BUILDING
APN 612-37-015
APN 612-37-017
APN 612-37-016
16'
R/W
15'
20'
DRIVEWAY
DR
IVE
WA
Y
LANDS OF BANSAL
LANDS OF BANSAL
LANDS OF McCLAIN
OUTLINE
5'
PROPOSEDDRIVEWAY
R/W
CLAYTON ROAD(CITY OF SAN JOSE MAINTAINED)
CLAYTON ROAD
(SANTA CLARA COUNTY MAINTAINED)
25'
25' 30'
72.50'TYPE B
TURNAROUND
G-2
PROPOSEDDRIVEWAY/TURNAROUND
AREA OFWORK
PROPOSED 45' EASEMENTFOR INGRESS, EGRESSAND UTILITIES PURPOSES
29'
13' WESTERLY PORTION OFBLANKET EASEMENT 128 D 166
4' PER 3986 D 381
9' PER 5513 D 576
16' PRIVATE ROAD (123 D 42)
20'
R/W
CENTERLINE PROPOSED PRO-RATA SHAREIMPROVEMENTS-CONSTRUCT 21' WIDE 312 L.F.OF NEW ROADWAY CONFORMING TO COUNTYSTANDARD DETAIL SD2, SEE SHEETS G-3, G-4,AND DETAIL 3/G-6
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
60.00'
G-3
22.50'20.00'
12.0
0'
30.00'
89.5' (P)
65' (P)
60' (P)65' (P)
60' (P)
65' (S)
60' (S)65' (S)
60' (S)
15.0
0'15
.00'
3/G-4
2/G-4
3/G-42/G-4
8" D
IA. S
DR
35 P
VC
12.5
0'
DS
DS
DS
DS
DS
DS
4/G-4
4/G-4
5/G-4
PRIV
ATE
ROAD
25.0
0'
5'3'
85.00'
UPPER F.F.=164.5' PAD=162.5'LOWER F.F.=154.5' PAD=153.0'
PROPOSED 3 BEDROOMSINGLE FAMILY HOUSE
DRIVEWAY
30.00'SETBACK
30.00'SETBACK
30.0
0'S
ETB
AC
K
AREA DRAIN AS NOTED PER 4 AND 7/G-6
CATCH BASIN AS NOTED PER 10/G-6
EDGE ROAD
S=IL/A x (100)S=AVERAGE SLOPE IN PERCENTI=CONTOUR INTERVAL (FEET)L=TOTAL COMBINED LENGTH OF CONTOURS (FEET)A=AREA OF DEVELOPED AREA (SQUARE FEET)
S=IL/A x (100) = 2 ft. x 6140 ft./43560 sq. ft. x 100 = 28.2%
FLOOR AREA RATIO = 4450 sq. ft./43560 sq. ft. = 10.2%
STORM DRAIN/SITE DRAINAGE
OVERHEAD SERVICE LINE
WATER LINE
CENTERLINE STREET
PROPERTY LINE
FENCE LINE
EXISTING CONTOUR LINE
SPOT ELEVATION
CURB AND GUTTER
RETAINING WALL PER LANDSCAPE PLAN
DIRECTION OF SURFACE FLOW
CLEANOUT
65.0'FINISH GRADE/FINISH ELEVATION
ROOF DOWNSPOUT TO CLOSED SYSTEM
COURTYARD
DRIVEWAY DRIVEWAY
72.50'TYPE B TURNAROUND
25.0
0'
GRADING ANDDRAINAGE/SEPTIC SYSTEMPLAN1. THIS IS A TOPOGRAPHIC MAP, NOT A BOUNDARY SURVEY.
ALL BOUNDARY LINES SHOWN ARE APPROXIMATE AND
SHOULD BE FIELD VERIFIED AS REQUIRED.
2. GEOTECHNICAL SOILS INVESTIGATION PREPARED BY
ASSOCIATED TERRA CONSULTANTS, INC. FILE NUMBER
178831, DATED SEPTEMBER 11, 2002. SEE ALSO UPDATE
LETTER DATED FEBRUARY 4, 2013.
3. PROPOSED DEVELOPED AREA IS ASSUMED AS THE
ENTIRE LOT AREA FOR PRELIMINARY PURPOSES FOR
SLOPE CALCULATION.
4. PROPOSED HOUSE SHALL BE 3 BEDROOM AND 4,450
SQUARE FEET MAXIMUM.
5. NO WELLS ARE LOCATED WITHIN 100 FEET OF THE
PROPERTY.
6. DOMESTIC WATER SHALL BE PROVIDED BY SAN JOSE
WATER COMPANY.
7. TOTAL PRIMARY AND SECONDARY LEACH FIELD LENGTH
REQUIRED = 490' PER PERCOLATION TESTS. A POPOVER
SYSTEM IS REQUIRED FOR THIS SITE, SEE DETAIL 5/G-5.
8. AVOID PLANTING TREES WITHIN THE DRAINFIELD OR
ADJACENT TO THE SEPTIC TANK. THERE SHALL BE NO
GRADING ACTIVITY WITHIN 10' OF THE PROPOSED
LEACHFIELDS.
9. SEPTIC SYSTEM INSTALLER MUST CONTACT ASSOCIATED
TERRA CONSULTANTS AT (408) 866-1047 AND THE COUNTY
DEPARTMENT OF ENVIRONMENTAL HEALTH AT (408)
918-3400 48 HOURS PRIOR TO BEGINNING WORK.
10. THE OWNER HAS SECURED A WILL SERVE DOCUMENT
FOR THE EXISTING FIRE HYDRANT LOCATED ACROSS THE
STREET FROM THE PROPERTY AT THE SOUTH SIDE OF
CLAYTON ROAD. THE EXISTING FIRE HYDRANT SHALL BE
VERIFIED TO COMPLY WITH THE MINIMUM FLOW RATES
AND PRESSURES REQUIRED BY THE FIRE MARSHAL.
11. LARGE TREES ON THE PROPERTY MUST MAINTAIN A
MINIMUM SETBACK OF 15 FEET BETWEEN LEACHLINES
AND TREES OVER 18 INCHES IN DIAMETER ME3ASURED
AT A HEIGHT OF 48" ABOVE THE GROUND.
NOTES:
LEGEND:
12" JOINTTRENCH
CLAYTON ROAD(CITY OF SAN JOSE MAINTAINED)
CLAYTON ROAD
(SANTA CLARA COUNTY MAINTAINED)
1/G-4
.1
PERCOLATION TEST HOLE AND NUMBER
WITH STABILIZED PERCOLATION RATE
NOTED IN MPI PER TESTS DATED 02/04/03
SURVEY CONTROL POINT/
TEMPORARY BENCHMARK
1/G-4
FINISH CONTOUR LINE
CENTER OF TREE W/ TRUNK
DIAMETER IN INCHES. SPECIES
NOTED WHEN KNOWN.
1/G
-4.1
1/G-4
5/G-4 4" DIA. SDR35 PVC DOWNSPOUT LATERAL
TO 6" DIA. SDR35 PVC STORMDRAIN LINE
15' M
IN.
±25.00' TOPROP. LINE
±28', 10' MIN. TOJOINT TRENCH
G-4
GRADING
SECTIONS
APPROVED FOR ISSUANCEREFER TO ENCROACHMENT AND/ORCONSTRUCTION PERMIT AND PLANCOVER SHEET FOR SPECIALCONDITIONS AND PERMIT NUMBERS
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
4/-3/- 5/-
1/-
1/-
1/-
5
SECTION
SCALE: 1"=10'-0" H:V
4
SECTION
SCALE: 1"=10'-0" H:V
2
SECTION
SCALE: 1"=20'-0" H:V
3
SECTION
SCALE: 1"=20'-0" H:V
1
DRIVEWAY PROFILE
SCALE: 1"=20'-0" H:V
PROPERTY LINE
PROPERTY
LINE
PROPERTY LINE
PROPERTY LINE
SETBACK LINE
PROPERTY LINE
SETBACK LINE
CLAYTON ROAD
L
C
SETBACK LINEPROPERTY LINE
PROPERTY LINE
SETBACK LINE
CLAYTON ROAD
L
C
G-4.1
GRADING
SECTIONS
APPROVED FOR ISSUANCEREFER TO ENCROACHMENT AND/ORCONSTRUCTION PERMIT AND PLANCOVER SHEET FOR SPECIALCONDITIONS AND PERMIT NUMBERS
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
A
PRIVATE ROAD
SCALE: 1"=20'-0" H:V
1
STA. 0+10
SCALE: 1"=10'-0" H:V
2
STA. 0+86
SCALE: 1"=10'-0" H:V
3
STA. 1+61
SCALE: 1"=10'-0" H:V
4
STA. 2+42
SCALE: 1"=10'-0" H:V
NTS
1
- REMOVE SEDIMENT BEHIND THE BARRIER WHEN IT REACHES A DEPTH OF 6 INCHES.
NOTE: IF DIKE IS CONSTRUCTED AT THE TOP OF SLOPE, PLACE IT 6'
- INSPECT WEEKLY AND AFTER EACH RAIN.
MINIMUM AWAY FROM THE SLOPE IF POSSIBLE.
MAINTENANCE
UNDISTURBED GROUND
1" Ø POLES AT 48" O.C.
INTO EXISTING SOIL
GEO-FABRIC SILTATION FENCING
EMBED GEO-FABRIC 4" MIN.
FLOW
18"
18"
NTS
3NTS
5
6
NTS
NTS
10
12
ORIGINAL GROUND SURFACE
BENCH 6' MINIMUM
KEY (1' MIN.)
COMPACTED FILL
SLOPE NOT TO EXCEED 2:1
OR PER SOILS REPORT
OR PER SOILS REPORT
SLOPE TOWARD DRAINS
2% MIN. IF REQ'D
ADD BENCH DRAINS
SUBGRADE AT 90% MIN. RELATIVE COMPACTION
AT 95% RELATIVE COMPACTION
9" CLASS II AGGREGATE BASE
3" ASPHALT CONCRETE
NTS
NTS
NTS
11
4
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
NTS
2NTSNTS
G-5
GRADING
DETAILS
12" CLAY CAP
EQ. EQ.
6'-0"
6'-0"
DETENTION SYSTEM TRENCH
W/ 3/4" CLEAN CRUSHED DRAIN
ROCK WRAPPED IN FILTER
FABRIC-MIRAFI 140N OR EQUAL
24" DIA. HDPE PIPE
W/ 1/4" DIA. HOLES
DRILLED AT 8" O.C.
ALONG CIRCUMFERENCE
AT 12" INTERVALS, TYP.
EQ.
EQ.
2" ROCK OVER
18"
PIPE
LEACHLINE PAPER/
UNTREATED BUILDING
6'-0
" D
EE
P M
IN
.
4'-0
" M
IN
. C
OV
ER
PAPER
4" DIA. PERFORATED
DRAINPIPE, TYP.
3/4" TO 2 1/2"
WASHED DRAINROCK
24"
DRILLED PIERS PER
P.T. BOARDS, S.S.D.
6"
DRAIN ROCK AND
FILTER FABRIC PER
SOILS REPORT
POST, S.S.D.
STRUCTURAL DRAWINGS
SEE ALSO GEOTECHNICAL REPORT FOR DRAINAGE RECOMMENDATIONS
6"
4" DIA. PERFORATED PIPE,
TY
P.
PILE RETAINING WALL
WOODEN SOLDIER
RETAINING WALL
CONCRETE
4" DIA. PERFORATED PIPE
AND FILTER FABRIC, SEE
ALSO GEOTECH REPORT
FOR SUPPLEMENTAL DRAINAGE
REQUIREMENTS
WATERSTOP,
WATERPROOFING
MEMBRANE
TYP. AT COLD
DRILLED PIERS AND FTG.
PER STRUCTURAL DRAWINGS
6"
TY
P.
SEE DETAIL 5/- FOR DRAINFIELD POPOVER
TEE CONNECTION, TYP.
LEACHLINE AS REQUIRED
PER PLAN, SEE 3/- FOR DEPTH
AND SLOPE REQUIREMENTS
48" MIN.
15' TYP. SEE PLAN FOR SPACING
OVERFLOW PIPE MUST BE
AT LEAST 4" LOWER THAN
SEPTIC TANK OUTLET, TYP.
EXISTING GRADE
LEACHLINE PAPER/
UNTREATED BUILDING
PAPER, TYP.
TIGHT LINE, TYP.
TEE CONNECTION, TYP.
SEE 3/-
48" MIN.
SEE 3/-
SEE DETAILS 3 AND 11/- FOR INFO.
NOT SHOWN
ADD SUBDRAINS AT THE DISCRETION OF THE GRADING
OFFICIAL AND/OR GEOTECHNICAL ENGINEER, TYP.
UTILITY BOX
(EXTEND INSPECTION PIPE
AS NECESSARY TO MATCH
FINAL GRADE
INSPECTION WELL
4" NON-PERFORATED
PLASTIC DRAINPIPE WITH
SLOTS OR HOLES DRILLED
THROUGHOUT DRAIN
ROCK DEPTH
NTS
1NTS
3NTS
6
NTS
NTSNTS
4
APPLICANT: BANSALROAD NAME: CLAYTON ROAD COUNTY FILE NO.
G-6
GRADING
DETAILS
10" DEEP OF 1"-2" MEAN SIZED
FILTER FABRIC
RIP RAP/ROCK
FOR AREA DRAIN (AD) USE NDS
90B 6" BRASS ATRIUM GRATE
TOP OF GRATE ELEV SHOWN ON PLANS
4" SDR-35 PVC
SDR-35 PVC REDUCER
SDR-35 PVC 45° BEND FITTING
SIZE AS SPECIFIED ON PLANS
SDR-35 PVC WYE FITTING
FLOW
IN-LINE
FOR AREA DRAIN (AD) USE NDS
90B 6" BRASS ATRIUM GRATE
TOP OF GRATE ELEV SHOWN ON PLANS
6" SDR-35 PVC 90° ELL
INVERT ELEV AS
DESIGNATED ON THE PLAN
END OF LINE
NOTE:
GLUED FITTINGS MAY BE SUBSTITUTED
FOR GASKETED FITTINGS AT THE OPTION
OF THE INSTALLATION CONTRACTOR
1'-6
" M
IN
.
NOTE:
GLUED FITTINGS MAY BE SUBSTITUTED
FOR GASKETED FITTINGS AT THE OPTION
OF THE INSTALLATION CONTRACTOR
IN-LINE
END OF LINE
18
" M
IN
.
6"
FLOW
FLOW
FLOW
TOP OF GRATE ELEV SHOWN ON PLANS
FOR AREA DRAIN (AD) USE CHRISTY V1
DRAIN BOX WITH V1-71C CAST IRON GRATE
GROUT
4" SDR-35 PVC
SDR-35 PVC REDUCER
SDR-35 PVC 45° BEND FITTING
SIZE AS SPECIFIED ON PLANS
SDR-35 PVC WYE FITTING
FOR AREA DRAIN (AD) USE CHRISTY V1
DRAIN BOX WITH V1-71C CAST IRON GRATE
GROUT
4"x6" SDR-35 PVC 90° ELL
INVERT ELEV AS
DESIGNATED ON THE PLAN
7
9
10
12
NOTE:
CONTRACTOR SHALL NOTIFY
OWNER IN WRITING OF THE
NEED FOR PERIODIC AND
REGULAR INSPECTION AND
CLEARING OF SILT BASINS FOR
LONG TERM PERFORMANCE
OPEN GRATE
CHRISTY V-24 OR SIMILAR
SILT BASIN
DRAINROCK BED. USE
3
4
" CLEAN
CRUSHED DRAINROCK W/ MIRAFI
140-N FILTER FABRIC
IN
OU
T
1' C
LE
AR
1'
IN
NTSNTS
NTS
THE EXACT LAYOUT CANNOT BE CONSTRUCTED DUE TO THE
EXISTING FIELD CONDITIONS AND ADJACENT PROPERTY
RESTRAINTS, SEE DETAIL 12/- FOR PROPOSED DESIGN
NTS
PROPERTY LINE
EDGE OF EXISTING ROAD
STA. 3+12
EASEMENT, SEE G-2
RETENTION SWALE,
SEE G-3
DRIVEWAY
A.B. SHOULDER
LANDS OF MCLAIN
LANDS OF BANSAL
PR
IV
AT
E A
CC
ES
S R
OA
D
A.B. SHOULDER
DRIVEWAY
APPROACH
PER SD4
A.C. CURB
A.C. CURB
A.B. SHOULDER
A.C. CURB
EASEMENT, SEE G-2
DRIVEWAY
A.B. SHOULDER
LANDS OF MCLAIN
LANDS OF BANSAL
PR
IV
AT
E A
CC
ES
S R
OA
D