OPEN TRAY IMPRESSION TECHNIQUE FOR BONE LEVEL IMPLANTS 1. Place the impression post into the implant. 5. Fill tray with impression material and take the impression. 9. The lab will select the corresponding analog and place the impression post into the implant analog and tighten the guide screw by using the SCS screwdriver. 2. Tighten the guide screw using the SCS screwdriver. 10. To avoid inaccuracies when connecting the implant analog, it must be positioned exactly in line with the grooves of the impression post before screwing in. 3. Prepare tray by creating access holes for the impression post. 7. Using the SCS screwdriver loosen the guide screw within the impression post. 11. When tightening the screw, stabilize the retentive section of the implant analog to prevent the impression post from rotating. 4. Apply impression material around the impression post. This ensures that a complete impression is taken. 6. Let the impression material cure. 12. The impression is now ready to be used to create a model. 8. Remove the impression from the patient’s mouth. RC COMPONENTS NC COMPONENTS 025.4202 RC Impression post, with guide screw 025.4101 RC Implant analog 025.2202 NC Impression post, with guide screw 025.2101 NC Implant analog 046.401 SCS screwdriver © Straumann USA, LLC 2009 Straumann products are CE marked USLIT 268 2/09 Straumann ® is a registered trademark of Straumann Holding AG, or its affiliates. All rights reserved. Procedure for NC and RC open tray impression taking is the same.

Straumann Bone Level Implant Impression Open Tray Final

Embed Size (px)

DESCRIPTION

Impression of Straumann Bone Level for Open tray

Citation preview

Page 1: Straumann Bone Level Implant Impression Open Tray Final

OPEN TRAY IMPRESSION TECHNIQUE FOR BONE LEVEL IMPLANTS

1. Place the impression post intothe implant.

5. Fill tray with impression material and take the impression.

9. The lab will select the corresponding analog and place the impression post into the implant analog and tighten the guide screwby using the SCS screwdriver.

2. Tighten the guide screw using the SCS screwdriver.

10. To avoid inaccuracies when connecting the implant analog, it must be positioned exactly in line with the grooves of the impression post before screwing in.

3. Prepare tray by creating access holes for the impression post.

7. Using the SCS screwdriver loosen the guide screw within the impression post.

11. When tightening the screw, stabilize the retentive section of the implant analog to prevent theimpression post from rotating.

4. Apply impression materialaround the impression post. This ensures that a complete impression is taken.

6. Let the impression material cure.

12. The impression is now readyto be used to create a model.

8. Remove the impression from the patient’s mouth.

RC COMPONENTS NC COMPONENTS 025.4202 RC Impression post,

with guide screw

025.4101 RC Implant analog

025.2202 NC Impression post, with guide screw

025.2101 NC Implant analog

046.401 SCS screwdriver

© S

traum

ann

USA

, LLC

200

9

Stra

uman

n pr

oduc

ts ar

e C

E m

arke

d

USL

IT 2

68

2/

09

Stra

uman

n® is

a re

giste

red

trade

mar

k of

Stra

uman

n H

oldi

ng A

G, o

r its

affil

iate

s. A

ll rig

hts

rese

rved

.

Procedure for NC and RC open tray impression taking is the same.