19
Impression procedure

Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

Embed Size (px)

Citation preview

Page 1: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

Impression procedure

Page 2: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

2EducationSTRAUMANN

Product portfolio for bone level implant impression procedures

Color coding per implant connection

Ø 3.3 mm

Impression Post

(open tray)

AnalogSnap-on capImpression Post

(closed tray)

Impression Post

(open tray)

Analog

Ø 4.1mm Ø 4.8 mm

Snap-on capImpression Post

(closed tray)

RCNC

Page 3: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

3EducationSTRAUMANN

Bone Level implant impression concept

2 impression techniques

Open tray impression Closed tray impression

The choice depends on user preference and the clinical situation

Page 4: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

4EducationSTRAUMANN

Open tray impressionConcept

Intraoral situationImplant & impression post Analog & impression post

Page 5: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

5EducationSTRAUMANN

ComponentsImpression post (TAN)*, guide screw (TAN)

Benefits Color-coded components correspond to prosthetic

connection

High precision impression

Clear-cut tactile response for accurate positioning Guide screw can be tightened by hand or with the

SCS screwdriver Adaptable in height (1 retention ring)

Length = synOcta® post + 2.8 mm

Open tray impressionConcept

Impression components are intended for single use only

*TAN is one type of titanium alloy material

Page 6: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

Step by step procedureOpen tray impression

Page 7: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

7EducationSTRAUMANN

Impression procedure

Remove closure screw or healing abutment

Insert impression post and hand tighten screw with the SCS screwdriver

Page 8: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

8EducationSTRAUMANN

Take impression with an open tray

Use an elastomeric impression material

Impression procedure

Page 9: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

9EducationSTRAUMANN

When impression material is set, unscrew and remove the impression

Impression procedure

Page 10: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

10EducationSTRAUMANN

Screw the implant analog onto the impression post and cast master model

Impression procedure

Page 11: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

11EducationSTRAUMANN

It’s recommended to articulate the master model before making the restoration

Page 12: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

12EducationSTRAUMANN

Components:Cap (Polymer), Post (TAN), Screw (TAN)

Benefits Color-coded components correspond to prosthetic

connection

No additional preparation of tray

High precision impression

Clear-cut tactile response for accurate positioning

Closed tray impressionConcept of snap-on impression cap

Impression components are intended for single use only

Page 13: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

13EducationSTRAUMANN

Closed tray impressionConcept of snap-on impression cap

Implant level impressionScrew retained impression post

Color coded snap-on cap & guide screw

RCNC

Page 14: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

Step by step procedureClosed tray impression

Page 15: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

15EducationSTRAUMANN

Impression procedure Remove closure screw or healing abutment

Insert impression post and hand tighten screw with the SCS screwdriver

Page 16: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

16EducationSTRAUMANN

Ensure that the colors match (cap and screw) and the arrows are positioned in a buccal-lingual direction

Snap impression cap onto the impression post

Impression procedure

Page 17: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

17EducationSTRAUMANN

Take impression with a closed tray

Use an elastomeric impression material

Impression procedure

Page 18: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

18EducationSTRAUMANN

Remove the impression Remove the impression post from implant Mount impression post onto the analog (same color) Reposition and snap back into the impression

Impression procedure

Page 19: Impression procedure. STRAUMANN 2 Education Product portfolio for bone level implant impression procedures Color coding per implant connection Ø 3.3 mm

19EducationSTRAUMANN

Cast master model

Articulate the master model before making the restoration

Impression procedure