1 CONTENTS I. Stand-alone node set-up ......................................................................................................................... 2 II. Configure the software environment and load, and commit the software. ....................................... 5 1. WebUI procedure: .............................................................................................................................. 6 2. CLI procedure : .................................................................................................................................. 9 III. Set the NE to operate in SDH mode ................................................................................................ 13 1. CLI procedure : ................................................................................................................................ 13 IV. Set the loopback IP address ............................................................................................................. 14 1. WebUI procedure : ........................................................................................................................... 14 2. CLI procedure : ................................................................................................................................ 14 V. Configure GNE for management system access ................................................................................ 15 1. WebUI procedure : ........................................................................................................................... 15 2. CLI procedure : ................................................................................................................................ 18 VI. Complete connection of inventory cables ....................................................................................... 18 1. WebUI Procedure : ........................................................................................................................... 18 2. CLI procedure : ................................................................................................................................ 20 VII. Insert duplicate equipment controller ............................................................................................ 21 VIII. Set the network element date and time ........................................................................................... 22 1. WebUI procedure : ........................................................................................................................... 22 2. CLI procedure : ................................................................................................................................ 23 IX. Disable ES port monitoring ............................................................................................................. 23 1. WebUI procedure : ........................................................................................................................... 23 2. CLI procedure : ................................................................................................................................ 24 X. Update firmware on all circuit packs ................................................................................................. 24 1. WebUI procedure : ........................................................................................................................... 24 2. CLI procedure : ................................................................................................................................ 25 XI. Configure additional system properties.......................................................................................... 25 1. WebUI procedure : ........................................................................................................................... 26 2. CLI procedure .................................................................................................................................. 26

Training Alcatel-Lucent WDM PSS 183x

Embed Size (px)

Citation preview

Page 1: Training Alcatel-Lucent WDM PSS 183x

1

CONTENTS I. Stand-alone node set-up ......................................................................................................................... 2

II. Configure the software environment and load, and commit the software. ....................................... 5

1. WebUI procedure: .............................................................................................................................. 6

2. CLI procedure : .................................................................................................................................. 9

III. Set the NE to operate in SDH mode ................................................................................................ 13

1. CLI procedure : ................................................................................................................................ 13

IV. Set the loopback IP address ............................................................................................................. 14

1. WebUI procedure : ........................................................................................................................... 14

2. CLI procedure : ................................................................................................................................ 14

V. Configure GNE for management system access ................................................................................ 15

1. WebUI procedure : ........................................................................................................................... 15

2. CLI procedure : ................................................................................................................................ 18

VI. Complete connection of inventory cables ....................................................................................... 18

1. WebUI Procedure : ........................................................................................................................... 18

2. CLI procedure : ................................................................................................................................ 20

VII. Insert duplicate equipment controller ............................................................................................ 21

VIII. Set the network element date and time ........................................................................................... 22

1. WebUI procedure : ........................................................................................................................... 22

2. CLI procedure : ................................................................................................................................ 23

IX. Disable ES port monitoring ............................................................................................................. 23

1. WebUI procedure : ........................................................................................................................... 23

2. CLI procedure : ................................................................................................................................ 24

X. Update firmware on all circuit packs ................................................................................................. 24

1. WebUI procedure : ........................................................................................................................... 24

2. CLI procedure : ................................................................................................................................ 25

XI. Configure additional system properties.......................................................................................... 25

1. WebUI procedure : ........................................................................................................................... 26

2. CLI procedure .................................................................................................................................. 26

Page 2: Training Alcatel-Lucent WDM PSS 183x

2

I. Stand-alone node set-up

Connect one end of the Ethernet cable to the CIT port on the active EC card (indicated by green

Active LED) on the master shelf. Connect the other end of the cable to the Ethernet port on your

PC.

Open a PC command window and type ipconfig and <Enter>. Verify the IP address assigned

by the NE to your PC is 172.16.0.x.

Launch Internet Explorer and enter http://172.16.0.1 in the Address bar. This is the

default IP address of the CIT port.

Note: Make sure Internet Explorer is not using a proxy server to access this address.

Click Go. The browser connects to the network element and the WebUI login window is displayed.

Page 3: Training Alcatel-Lucent WDM PSS 183x

3

Initialize the database

A warning message will indicating that the database is uninitialized.

If the warning message does not appear, this is an indication that there is a database already on the

EC.

USE:( Use a telnet application on your PC and open a telnet session connected to the IP address of the

CIT port.

• The default address for an uncommissioned NE is 172.16.0.1

Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.

Type cli at the Password: prompt and <Enter>.

This starts the CLI, and another Username: prompt will appear. Type admin and

<Enter>.

Type config database clear.

)

Click “OK” and the system will automatically restart after initialization. A window will appear

showing the restart progress.

Page 4: Training Alcatel-Lucent WDM PSS 183x

4

After the restart is complete, the system will prompt you for a new NE name. Type the NE name.

Click the “Submit” button and the system will restart once again. The restart will take

approximately 2 minutes.

After the restart is complete, the WebUI will open with the system properties view.

Page 5: Training Alcatel-Lucent WDM PSS 183x

5

II. Configure the software environment and load,

and commit the software.

Start the FTP server application on your PC and create a user account. Record the userid and

password established for the account.

Establish a root directory for the server and make sure it has read and write privileges. You may

create a folder in the root directory that will contain the NE software.

Copy the folder and subfolders with the NE software into the FTP root directory

established above.

Note: The software folder name to be copied is 1830PSS32-3.0-00. There should

also be two subfolders named “1830PSS32” and “1830PSS32M” as well as a

CATALOG file.

Open Windows Firewall from the Control Panel.

Select Off. Then click OK.

Open a PC command window and type ipconfig and <Enter>. Once again verify the IP address

assigned by the NE to your PC is 172.16.0.x.

Page 6: Training Alcatel-Lucent WDM PSS 183x

6

Important! If this is an Alcatel-Lucent 1830 PSS-16 shelf, use the CLI

(command) procedure.

1. WebUI procedure:

Select the Software menu item under Administration and then select FTP Server.

The FTP server settings window appear.

Page 7: Training Alcatel-Lucent WDM PSS 183x

7

Enter NE IP address obtained earlier using ipconfig for the Server IP Address.

Enter the path to the NE software relative to the server root directory in the “Root Directory” field.

Note: If the software folder was copied directly into the root directory, enter / in

this field.

Enter the UserID and Password to match the account created on the FTP server. Click the “Apply” button.

Select Administration -> Software -> Upgrade from the top menu.

The Software Upgrade window appears.

Note: The software release will be the current factory load.

Select “Audit” from the “Action Type” drop-down list.

Enter the folder name containing the NE software in the “Release Directory” field. The folder

name for Release 3.0 should be 1830PSS32-3.0-00.

Click “Apply” and the “Status” field will change to “In Progress”.

Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the

“Result” is “Success” and the “Upgrade Path Available” field indicates “Yes”.

Select “Download” for the “Action Type” and click “Apply”. The “Status” field will change

to “In Progress”.

Periodically click the “Refresh” button until the “Status” field changes to “Completed”.Verify the

“Result” is “Success”.

Page 8: Training Alcatel-Lucent WDM PSS 183x

8

Select “Activate” for the “Action Type” and click “Apply”. The “Status” field will change to “In

Progress”. The NE will then reboot, and the WebUI will automatically logout.

Wait about 2 minutes after the fan speed drops back down to normal speed and log back into the

NE (typically 10 minutes after activate).

Return to the Software Upgrade window by selecting Administration -> Software -> Upgrade

from the top menu. Verify the “Status” field now indicates “Completed”, and verify the

“Result” is “Success’.

Select “Commit” for the “Action Type” and click “Apply”. The “Status” field will change to “In

Progress”.

Periodically click the “Refresh” button until the “Status” field changes to “Completed”.

Verify the “Result” is “Success”.

Verify the Active and Committed releases have changed to the new release.

Page 9: Training Alcatel-Lucent WDM PSS 183x

9

2. CLI procedure :

Use a telnet application on your PC and open a telnet session connected to the IP address of the

CIT port.

• The default address for an uncommissioned NE is 172.16.0.1

Hit <Enter> and the login: prompt will appear. Type cli and <Enter>.

Type cli at the Password: prompt and <Enter>.

This starts the CLI, and another Username: prompt will appear. Type admin and

<Enter>.

Type config software server ip <ip> and <Enter>.

Where <ip> is the ip address of the PC with the FTP server. This is the same ip address

obtained using the ipconfig command in the PC command window.

Type config software server userid <userid> and <Enter>.

Where <userid> is the user_id for the user account defined on the FTP server.

Type <pw> and <Enter>.

Where <pw> is the password for the user account defined on the FTP server. Type config software server root <path> and <Enter>.

Where <path> is the path to the NE software relative to the server root directory.

Note: If the software folder was copied directly into the root directory, enter / for the

<path>.

Type config software server detail and <Enter>.

Sample output below.

Software Server Protocol : FTP

Software Server IP : 172.16.0.2

Software Server Userid : sw1

Software Server Root Directory : /

Verify the server settings are correct.

Type config software upgrade status and <Enter>.

Page 10: Training Alcatel-Lucent WDM PSS 183x

10

Sample output below.

Software Upgrade Information:

Software Server IP : 172.16.0.2

Software Server Root Directory : /

Committed Release :

Working Release Directory :

Working Release : 1830PSS32-0.00-7

Active Release : 1830PSS32-0.00-7/

Operation :

Operation Status :

Upgrade Path Available : True

Software Download Script (Timezone: ):

Verify the current active software is an older release than software you are loading. Type config software upgrade manual audit <releasedir> nobackup and <Enter>.

Where <releasedir> is the directory name on the PC containing the software. The folder

name for Release 3.0 should be 1830PSS32-3.0-00.

Type config software upgrade status and <Enter>.

A listing of packs will be displayed along with the status showing which packs need to be

upgraded. Sample output below.

Software Upgrade Information:

Software Server IP : 172.16.0.2

Software Server Root Directory : /SVT/

Committed Release :

Working Release Directory : 1830PSS32-0.00-7/

Working Release : 1830PSS32-0.00-7

Active Release : 1830PSS32-0.00-7

Operation : Audit

Operation Status : Completed

Upgrade Path Available : True

Software Download Script (Timezone: ):

Stage=0 Step=1 SH/SL: 1/1 CARDTYPE: EC

ACTION: Audit node Completed 100% complete

Page 11: Training Alcatel-Lucent WDM PSS 183x

11

RESULT: Success

Stage=1 Step=0 SH/SL: 0/0 CARDTYPE: Empty

ACTION: Transfer to disk Planned 0% complete

RESULT: None

Stage=2 Step=0 SH/SL: 1/1 CARDTYPE: EC

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=0 SH/SL: 1/2 CARDTYPE: AHPHG

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=1 SH/SL: 1/3 CARDTYPE: CWR8

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=2 SH/SL: 1/7 CARDTYPE: 11STAR1

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=3 SH/SL: 1/13 CARDTYPE: 11STAR1

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=5 SH/SL: 1/15 CARDTYPE: CWR8

ACTION: Activate Planned 0% complete

RESULT: None

Stage=3 Step=6 SH/SL: 1/17 CARDTYPE: ALPHG

ACTION: Activate Planned 0% complete

RESULT: None

Repeat config software upgrade status until the Operation Status indicates Completed. Verify the

Upgrade Path Available changes to True.

Type config software upgrade manual load and <Enter>. This will transfer the software to the NE.

Type config software upgrade status and <Enter>. Watch for the following lines.

...

Operation : Load

Operation Status : In Progress 0%

...

Continue to execute the status command until the Operation Status shows Completed.

Page 12: Training Alcatel-Lucent WDM PSS 183x

12

Type config software upgrade manual activate and <Enter>.

This will activate the software on the EC card.

The NE will reboot and the telnet connection will drop. Wait about 2 minutes after the fan speed

drops back to normal speed and log back into the NE (typically 10 minutes after activate). Then

Connect to the NE for CLI access.

Type config software upgrade status and <Enter>.Watch for the following lines.

...

Operation : Activate

Operation Status : In Progress 0%

...

Continue to execute the status command until the Operation Status shows Completed.

Note: The output will also display the progress of the activation on each of the packs

in the NE. The Operation Status will not show completed until all packs have been

activated on the new release.

Type config software upgrade commit and <Enter>. This will commit the software to be the

primary release. Type config software upgrade status and <Enter>. Watch for the following lines.

...

Operation : Commit

Operation Status : In Progress 0%

...

Continue to execute the status command until the Operation Status shows Completed.

After the last status command is executed, verify the new software release is displayed as the

committed, working and active release. See the sample output below.

Software Upgrade Information:

Software Server IP : 172.16.0.2

Software Server Root Directory : /

Committed Release : 1830PSS32-3.0-00

Working Release Directory : 1830PSS32-3.0-00/

Working Release : 1830PSS32-3.0-00

Active Release : 1830PSS32-3.0-00/

Operation : Commit

Operation Status : Completed

Upgrade Path Available : False

Software Download Script (Timezone: ):

Page 13: Training Alcatel-Lucent WDM PSS 183x

13

NOTE : If this is an Alcatel-Lucent 1830 PSS-16 shelf, the following command is required to

bring the node up as an Alcatel-Lucent 1830 PSS-16.

Type config database clear and <Enter>.

The shelf will reboot and when the reboot completes the shelf will be correctly configured

as an Alcatel-Lucent 1830 PSS-16 shelf.

III. Set the NE to operate in SDH mode

Background

The NE defaults to SONET mode. You need to perform this procedure only if you want

the NE to operate in SDH mode.

NOTICE This procedure should only be executed when a system is first turned up.

1. CLI procedure :

Type show version and <Enter>.

Sample output:

Software Version: 1830PSS32-3.0-00

Copy the string after “Software Version”. This will be used as the password for the SDH mode

command.

Type config admin mode sdh <pw> and <Enter>.

Where <pw> is the password copied in the previous step.

The following warning will appear.

WARNING: Changing the SONET/SDH mode will cause the database to be

cleared, the node to be cold reset and all services to be

deleted.

Type yes and <Enter>. You will be logged out. This procedure is complete.

Page 14: Training Alcatel-Lucent WDM PSS 183x

14

IV. Set the loopback IP address

1. WebUI procedure :

Select “System” from the tree and the “Details” tab.

At the “Loopback IP Address” field, enter the IP address designated in the site documentation.

At the “Loopback Subnet Mask” field, enter the subnet mask designated in the site documentation.

Click the “Submit” button.

Click “OK.” The system will reboot, and WebUI will automatically logout.

Wait for the system to reboot (watch for the CIT link light to turn green) and log back into the

WebUI.

2. CLI procedure :

Type config interface loop ip <address>/<mask> and <Enter>.

Where <address> is the IP address and <mask> represents the subnet mask following the

CIDR format. Obtain this information from the site documentation.

Page 15: Training Alcatel-Lucent WDM PSS 183x

15

The following warning message will appear.

WARNING: Changing the loopback IP address will result

in a warm reset of this network element.

Enter 'yes' to confirm, 'no' to cancel:

Type yes and <Enter>. The CLI session will be terminated.

V. Configure GNE for management system access

Purpose

This procedure will provision and enable the OAMP port so that the NE can act as a

Gateway Network Element. The procedure will also provision the IP route information to

allow connection to RNEs. Not all NEs (i.e. RNEs) require this provisioning. Refer to the

site documentation.

1. WebUI procedure :

Expand “Shelf 1” in the equipment tree and then expand “slot 40: USRPNL” (slot 10 for PSS-16).

Select OAMP. The OAMP port provisioning window will appear.

Page 16: Training Alcatel-Lucent WDM PSS 183x

16

Enter the IP address and subnet mask as indicated in the site documentation.

Check the Port Enabled checkbox.

Click the “Submit” button.

Select Administration -> Networking -> IP Routes from the top menu.

The IP Routes screen is displayed.

Click the “Create” button. The Create IP Routes screen is displayed.

Page 17: Training Alcatel-Lucent WDM PSS 183x

17

Enter the parameters based on the site documentation.

Click the “Apply” button.

Verify the new IP route is now shown in the IP routes.

Page 18: Training Alcatel-Lucent WDM PSS 183x

18

2. CLI procedure :

Type config interface usrpnl oamp ip <address>/<mask> and <Enter>.

Where <address> is the IP address and <mask> represents the subnet mask following the

CIDR format. Obtain this information from the site documentation.

Type config interface usrpnl oamp state up and <Enter>.

Type config cn routes default add <address> and <Enter>.

Where <address> is the gateway address from the site documentation

Type config interface usrpnl oamp rou en and <Enter>.

VI. Complete connection of inventory cables

Purpose

The inventory cables will be connected and DCM, SFD44, SFD44B, and ITLB units

discovered in this procedure following the site documentation.

Note: If the DCM, SFD44, SFD44B, and ITLB shelf numbering contains non

contiguous numbers (numbers are skipped), the shelves must be manually pre-

provisioned before the inventory cables are connected. This procedure takes care of

that case.

1. WebUI Procedure :

Observe the equipment tree in the left window of the system view and verify there are no shelves

numbered 25 or greater.

Page 19: Training Alcatel-Lucent WDM PSS 183x

19

Refer to the site documentation to determine the shelf numbering of the DCM, SFD44,

SFD44B, and ITLB units. List them in order starting with 25.

Does the shelf numbering contain non contiguous numbers (numbers are skipped)?

If yes, skip to steps between two ().

If no, continue.

Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been

discovered and connect the inventory cable to that unit.

Wait 2 minutes and click the refresh button (the double arrows located at the top of the

equipment tree).

The new shelf should appear in the tree with the appropriate shelf number. If not, repeat clicking

refresh If the shelf still does not appear, check the cable connection or replace the inventory

cable.

Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered?

If yes, repeat the last 3 steps.

If no, end of steps.

() In the System view, select the “Create Shelf” tab. The Create Shelf view will appear.

Enter the appropriate provisioned type and shelf ID number of the next DCM, SFD44, SFD44B,

or ITLB shelf to be added. Enter additional parameters as required, then click the “Apply”

button.

Repeat until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.

Close the create shelf window and verify all the DCM, SFD44, SFD44B, and ITLB shelves now

appear correctly in the equipment tree.

Page 20: Training Alcatel-Lucent WDM PSS 183x

20

Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.

Check the alarms on the system and verify there are no equipment alarms related to the DCM,

SFD44, SFD44B, or ITLB shelves. ()

2. CLI procedure :

Type show shelf * and <Enter>.

Sample output.

Shelf 1 Information

Name : Master Shelf

Description : Master Shelf

ExpectedAmps : 30

Programmed Type : Universal Shelf Present Type : Universal

Shelf

Verify there are no shelves number 25 or greater.

Refer to the site documentation to determine the shelf numbering of the DCM, SFD44,

SFD44B, and ITLB units. List them in order starting with 25.

Does the shelf numbering contain non contiguous numbers (numbers are skipped)?

If yes, skip to steps between two ().

If no, continue.

Determine the next sequential DCM, SFD44, SFD44B, or ITLB unit that has not been

discovered and connect the inventory cable to that unit.

Wait 2 minutes and type show shelf * and <Enter>.

The new shelf should be listed in the output with the appropriate shelf number. If not, repeat

show shelf. If the shelf still does not appear, check the cable connection or replace the inventory

cable.

Are there additional DCM, SFD44, SFD44B, or ITLB units to be discovered?

If yes, repeat the last 3 steps.

If no, end of steps.

Page 21: Training Alcatel-Lucent WDM PSS 183x

21

()Type config shelf <shelf> type <type> and <Enter>.

Where <shelf> is the shelf number of the next shelf to be created and <type> is either dcm,

sfd44, sfd44b, or itlb.

Repeat this step until all the DCM, SFD44, SFD44B, and ITLB shelves have been created.

Type show shelf * and <Enter>.

Verify all the shelves that were created are now listed correctly.

Connect the inventory cables to all the DCM, SFD44, SFD44B, and ITLB units.

Type alm and <Enter>.

Verify there are no equipment alarms related to the DCM, SFD44, SFD44B, or ITLB shelves. ()

VII. Insert duplicate equipment controller

Purpose

In this procedure, the duplicate Equipment Controller (EC), if equipped, in slot 18 will be

installed. The EC from the factory will have the factory software and firmware already

installed on the pack. After seating the pack, the EC will synchronize with the existing EC

in slot 1.

Note: If the shelf is equipped with only one EC, skip this procedure.

Once again verify that both EC circuit packs in the shelf have Part Number (APN) 8DB59241AB.

Fully seat the EC circuit pack in slot 18. If the NE is equipped with multiple shelves, insert the slot

18 EC on each shelf.

Note: “software mismatch” and “database unsynchronized” alarms will appear.

These alarms will clear after the EC’s are synchronized.

Wait at least 15 minutes and verify the “software mismatch” and “database unsynchronized” alarms

have cleared.

Page 22: Training Alcatel-Lucent WDM PSS 183x

22

VIII. Set the network element date and time

Purpose

The network element date and time should be initially set manually using the network

element’s internal clock. The network element can later be synchronized with a network

time protocol (NTP) server. This procedure performs the initial setting manually.

1. WebUI procedure :

Select the Date/Time menu item under Administration.

The Date/Time provisioning window appears.

Enter the current date and time and time zone settings and click the “Apply” button.

Note: All current WebUI users will be logged off.

Page 23: Training Alcatel-Lucent WDM PSS 183x

23

2. CLI procedure :

Type config general date <date> and <Enter>.

Where date is of the format yyyy mm dd.

Type config general time <time> and <Enter>.

Where time is of the format hh mm ss, and hh is between 0 and 23.

IX. Disable ES port monitoring

Purpose

By default, the ES (Extension Shelf) ports on the EC packs are monitored. This will generate an alarm for

each port that does not have a lan cable connected. Therefore, if the NE does not have any extension

shelves, the EC port monitoring should be disabled.

Note: If the NE has extension shelves installed, this procedure should not be completed.

There is no need to disable the port monitoring.

1. WebUI procedure :

Expand “Shelf 1” in the equipment tree and then expand each of the EC packs.

Select an ES port (ES1 or ES2) that is currently in alarm. The ES port provisioning window

will appear.

Uncheck the Port Enabled checkbox and click “Submit”.

Repeat the last two steps until all the ES port alarms have cleared.

Page 24: Training Alcatel-Lucent WDM PSS 183x

24

2. CLI procedure :

Type config interface ec <sh/sl/pt> state down and <Enter>.

Where <sh/sl/pt> is the shelf, slot (1 or 18), and port (ES1 or ES2) of the ES port that is in

alarm.

Repeat the last step until all the ES alarms have cleared.

X. Update firmware on all circuit packs

Purpose

This procedure will ensure that the latest firmware is uploaded to all the installed circuit packs. This is

done by performing a cold reboot on the NE.

1. WebUI procedure :

Select the reboot tab from the system view.

Select the Cold Reboot radio button and click the “Submit” button.

The following warning message will appear. Click “OK”.

Page 25: Training Alcatel-Lucent WDM PSS 183x

25

The NE will reboot. The reboot will take several minutes depending on the number of circuit

packs requiring a firmware upgrade.

2. CLI procedure :

Type config admin resetNE cold and <Enter>.

The following warning message will appear. Type yes and <Enter>.

WARNING: You are about to perform a cold system restart.

This is a service affecting command.

Enter 'yes' to confirm, 'no' to cancel:

The NE will reboot. The reboot will take several minutes depending on the number of circuit

packs requiring a firmware upgrade.

XI. Configure additional system properties

Purpose

This procedure allows changes to system properties including temperature units and AINS

timer. The AINS timer value is system-wide and will become the default for all ports; the

value can be overridden on each individual port. See the Alcatel-Lucent 1830 Photonic

Service Switch 32/16 (1830 PSS-32/PSS-16) User Provisioning Guide, Equipment

Provisioning for more information on the AINS timer.

Page 26: Training Alcatel-Lucent WDM PSS 183x

26

1. WebUI procedure :

Select “System” from the tree and the “Details” tab.

Select or type in the AINS Timer value to use as the system-wide default.

Select the desired value for the Temperature Units to be used in the system.

Click the “Submit” button.

2. CLI procedure

To change the AINS timer value, type config general ainstimer <hours> and <Enter>.

Where <hours> is of the format <hh> [<mm>]. You can also type config general ainstimer

help for the default value and range.

The temperature unit defaults to Celsius. To change the temperature units to Fahrenheit, type

config admin tempUnits fahrenheit and <Enter>.