92
• Critical overview of HMC, IBM i, FSP, and firmware: Putting the pieces together. Pete Massiello iTech Solutions [email protected] 203-744-7854 iTech Solutions because IBM i (AS/400’s) didn’t come with System Administrators. 0

Critical overview of HMC IBM i FSP and firmware

Embed Size (px)

DESCRIPTION

COMMON Europe Congress 2012 - Vienna

Citation preview

Page 1: Critical overview of HMC IBM i FSP and firmware

• Critical overview of HMC, IBM i, FSP,

and firmware: Putting the pieces

together.

Pete Massiello

iTech Solutions

[email protected]

203-744-7854

iTech Solutions because IBM i (AS/400’s) didn’t come with System Administrators.

0

Page 2: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 1

In this session

We will cover what you need to know about the Hardware Management Console, the Flexible Service Processor, and IBM i. What they are, how we connect them together, the relationships amongst one another, and how we perform upgrades to each. In addition, you will learn basic maneuverability around the HMC as we discuss all these tasks.

Page 3: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 2

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 4: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 3

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 5: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 4

i5/OS, FSP, and HMC

i5/OS Linux i5/OS

A B

SLIC

A B

SLIC

Power Hypervisor PHYP

Flexible Service Processor (FSP)

Flash Memory

Perm Temp

HMC 1

HMC 2

System Power Cont. Network (SPCN)

Page 6: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 5

Hardware Management Console (HMC)

• Intel based PC “appliance” running LINUX for managing of

partitions on Power5, Power6, and Power7 hardware

• Functions:

Management of Partitions

HMC Licensed Internal Code Maintenance

HMC Users and Configuration

Service Applications

Local Info Center

Page 7: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 6

HMC

• Easy to Manage

• Can Be Used as Console

• Remote Console Access

• Remote Access of HMC (WebSM Pre V7.3)

• Partitions Can Run Without Connection to HMC

• Provides Direct Link to ASMI (Advanced Systems Management

Interface)

Page 8: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 7

HMC 7310-CR3 – Rack mounted

Page 9: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 8

HMC 7310-C04

1 PCI connectors (slot 1 to left)

2 PCI Express (x1) connector

3 PCI Express (x16) graphics connector

4 Ethernet connector

5 USB connectors

6 Mouse connector

7 Parallel connector

8 System connector

9 Diagnostic LEDs

10 Power connector

11 Audio line-out connector

12 Audio line-in connector

13 VGA monitor connector

14 System connector

15 Keyboard connector

16 USB connectors

Note: Versions earlier than 7310-C04 will not

load HMC 7.7 and later.

Page 10: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 9

i5/OS, FSP, and HMC

i5/OS Linux i5/OS

A B

SLIC

A B

SLIC

Power Hypervisor PHYP

Flexible Service Processor (FSP)

Flash Memory

Perm Temp

HMC 1

HMC 2

System Power Cont. Network (SPCN)

Page 11: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 10

Flexible Service Processor (FSP)

• The service processor runs on its own power boundary and

continually monitors hardware attributes and the environmental

conditions within the server.

• The FSP is responsible for loading the PHYP code from Flash into

system memory and starting the system processors. FSP does

not deal directly with OS/400 SLIC nor IBM® AIX®/Linux® Open

Firmware/RTAS. FSP directly communicates only with the Real

Control Panel, PHYP, or the HMC.

• The Flexible Service Processor (FSP) firmware provides

diagnostics, initialization, configuration, run-time error detection,

and correction.

Page 12: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 11

Advanced Systems Management Interface (ASMI)

• Service Processors Menus

• Connect via https and your Browser through HMC 1 and HMC 2

ports on i5 using addresses:

Power5: 192.168.2.147 and 192.168.3.147

Power6 & 7: 169.254.2.147 and 169.254.3.147

• Perform general and administrator-level service tasks such

as reading service processor error logs, reading vital product

data, setting up the service processor, and controlling the

system power.

Page 13: Critical overview of HMC IBM i FSP and firmware

ASMI

Page 14: Critical overview of HMC IBM i FSP and firmware

ASMI – Firmware Update Policy

Page 15: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 14

LIC and i5/OS

• This has not changed. Still Licensed Internal Code 5722-999,

5761-999, 5770-999.

• i5/OS is 5722-SS1, 5761-SS1, or 5770-SS1.

• Loaded on EACH partition.

• Not shared between partitions.

• LIC is NOT Server firmware on the FSP.

Page 16: Critical overview of HMC IBM i FSP and firmware

15 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 17: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 16

Connectivity

Eth0

Eth1

HMC

Port 1

Page 18: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 17

Connectivity (cont.)

• HMC ETH0

Configured as DHCP server

Unique set of addresses

Connects to closed network

FSP Port HMC1

• HMC ETH1

Connected to open network

Remote connections come in through here

Internet connection – ordering PTFs, updates

Page 19: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 18

Releases – Server Firmware

• Server Firmware: PPNNSSS_FFF_DDD:

PP = package identifier; 01 = managed system and 02 = power

subsystem.

NN = machine type model group; SF = system firmware P5, BP

= bulk power, Ex = Power6 (x=L, M, or H), Ax = Power7

SSS = fixpack code stream indicator

FFF = fixpack number for current fixpack level

DDD = fixpack number for the last disruptive fixpack level

• Power5 : 01_SF240_338_320

• Power6: EM310_057_048

• Power7: AL730_043

Page 20: Critical overview of HMC IBM i FSP and firmware

19 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 21: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 20

Upgrade Order

• First: HMC

• Next: FSP

• Last: LIC and i5/OS

Page 22: Critical overview of HMC IBM i FSP and firmware

21

HMC and FSP Combinations

Page 23: Critical overview of HMC IBM i FSP and firmware

Update HMC (From V6 and Earlier)

Page 24: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions

Update HMC

Page 25: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 24

Updating the HMC

• Recovery Media

Bootable DVD

Version Upgrade

• Corrective Service

CD

Internet download/FTP site

Like a PTF

Page 26: Critical overview of HMC IBM i FSP and firmware

Two Types of Backups – HMC Data (Critical Console Data)

Page 27: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions

Save Upgrade Data

Page 28: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions

Corrective Service: HMC PTFs

Page 29: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 28

FSP: PTFs vs. Version

• Change License Internal Code for the current release: Like putting

on a PTF

• Upgrade License Internal Code to a new release: Like a new

version. i.e., 01_SF235 to 01_SF240

Page 30: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 29

New Release or Version

• Done as an “IPL” of the HMC using Bootable DVD

• Always do SAVE Upgrade Data Before.

• Always backup to External Media: CD or USB Flash-Drive

Page 31: Critical overview of HMC IBM i FSP and firmware

Change FSP Code

Page 32: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 31

Permanently Apply What Is Temp

Page 33: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 32

FSP: Advanced Features

Page 34: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 33

FSP: Perm Apply

Page 35: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 34

Successful

Page 36: Critical overview of HMC IBM i FSP and firmware

35

Change Server Code (Within Release)

Page 37: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 36

Select Source of Update

Page 38: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 37

Run Through the Wizard

Page 39: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 38

FSP: Update Licensed Internal Code

Page 40: Critical overview of HMC IBM i FSP and firmware

39

FSP: Get the Lawyers Involved

Page 41: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 40

FSP: About to Update

Page 42: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 41

FSP: What Levels Will Be

Page 43: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 42

FSP: No HMC

• Firmware Service Update Policy MUST be set to OS Managed.

• Updates received from MH PTFs on 5722-999 (V5R4M0). If

V5R4M5, V6R1, or V7R1 then 5733-90x where x is 5 for Power5 or

6 for Power6, 7 is for Power7.

• To display the level:

Run the STRSST command.

Select Option 1, Start a service tool.

Select Option 4, Display/Alter/Dump.

Select Option 1, Display/Alter storage.

Select Option 2, Licensed Internal Code (LIC) data.

Select Option 14, Advanced analysis.

Select FLASHLEVELS, Press the Enter key.

Page 44: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions

DSPFMWSTS

Page 45: Critical overview of HMC IBM i FSP and firmware

44 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 46: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 45

LVT and System Plans

• LPAR Validation Tool (LVT). Now old.

• System Planning Tool. New.

• Define the configuration of the i5

• Where the cards go

• Which resources are on which partitions?

• Divides Memory and CPW (Batch and Interactive)

• Run from your PC

Page 47: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 46

Download SPT

Page 48: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 47

System Planning Tool

Page 49: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 48

SPT: Card Placement

Page 50: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 49

SPT: Card Placement (cont.)

Page 51: Critical overview of HMC IBM i FSP and firmware

50 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 52: Critical overview of HMC IBM i FSP and firmware

51

HMC 7 Welcome Screen

Page 53: Critical overview of HMC IBM i FSP and firmware

Partitions and Profiles

Page 54: Critical overview of HMC IBM i FSP and firmware

Activate: Starting a Partition

Page 55: Critical overview of HMC IBM i FSP and firmware

54

Activation

• Changes take affect at Activation not at PWRDWNSYS

Restart(*YES)

• Looks for Min Resources to activate

Page 56: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 55

Activation Partition Advanced Opt

Page 57: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions

Partition Starting

Page 58: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions

Replaces Front Bezel for Partitions

Page 59: Critical overview of HMC IBM i FSP and firmware

58

History of SRC Codes

Page 60: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions 59

Reference Codes

Page 61: Critical overview of HMC IBM i FSP and firmware

Partition Shutting Down

Page 62: Critical overview of HMC IBM i FSP and firmware

61 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 63: Critical overview of HMC IBM i FSP and firmware

HMC Users and Configuration

Page 64: Critical overview of HMC IBM i FSP and firmware

63

HMC Users

Page 65: Critical overview of HMC IBM i FSP and firmware

64

HMC: Add a User

Page 66: Critical overview of HMC IBM i FSP and firmware

HMC Configuration

Page 67: Critical overview of HMC IBM i FSP and firmware

66

HMC: Network Settings

Page 68: Critical overview of HMC IBM i FSP and firmware

67

HMC: Network Adapters

Page 69: Critical overview of HMC IBM i FSP and firmware

68

HMC: ETH0: Private Network

Page 70: Critical overview of HMC IBM i FSP and firmware

69

HMC: ETH1: Open Network

Page 71: Critical overview of HMC IBM i FSP and firmware

70

HMC: ETH1: Internal Firewall

Page 72: Critical overview of HMC IBM i FSP and firmware

71

HMC: DNS and Routing

Page 73: Critical overview of HMC IBM i FSP and firmware

72

HMC: Schedule Tasks

Page 74: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 73

Backup Critical Console Data

Page 75: Critical overview of HMC IBM i FSP and firmware

74 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 76: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions

HMC: Service Agent

Page 77: Critical overview of HMC IBM i FSP and firmware

76

HMC: Send Service Notifications

Page 78: Critical overview of HMC IBM i FSP and firmware

Attention LEDs

Page 79: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions 78

Manage Attention LEDs

78

Page 80: Critical overview of HMC IBM i FSP and firmware

79

HMC: Turn Alert Light Off

Page 81: Critical overview of HMC IBM i FSP and firmware

80

System Attention LED

Page 82: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions 81

Operator Panel Service Functions

Page 83: Critical overview of HMC IBM i FSP and firmware

82 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 84: Critical overview of HMC IBM i FSP and firmware

83

HMC and System Plans

Page 85: Critical overview of HMC IBM i FSP and firmware

84

HMC: Import System Plan

Page 86: Critical overview of HMC IBM i FSP and firmware

Copyright 2007 iTech Solutions 85

Manage System Plans

Page 87: Critical overview of HMC IBM i FSP and firmware

86 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 88: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 87

No more WebSM – Use HTTPS

Page 89: Critical overview of HMC IBM i FSP and firmware

88 Copyright iTech Solutions

What We’ll Cover …

• What Is Each Component?

• How Are They Connected?

• How Do We Upgrade?

HMC Code Update

FSP Server Code Update

• System Plans (Old LVT)

• Partitions and Profiles

• HMC Users and Configuration

• Service Agent

• Using System Plans

• Using Remote Connections (Was WebSM)

• Wrap-up

Page 90: Critical overview of HMC IBM i FSP and firmware

Resources

• For HMC Updates:

www14.software.ibm.com/webapp/set2/sas/f/hmcl/home.html

• For FSP Updates:

www14.software.ibm.com/webapp/set2/sas/f/power5cm/home.html

Page 91: Critical overview of HMC IBM i FSP and firmware

Copyright iTech Solutions 90

7 Key Points to Take Home

• Configure HMC before powering on i5

• ETH0 on HMC configured as a private network with DHCP.

• Remote Access to your HMC via HTTPS://ip-address

• Update of software order is important

HMC, FSP, LIC, and i5/OS

• Use System Planning Tool to design your machine

• Remember a Disruptive update to the FSP will immediately end all

partitions if they are still active

• Backup your HMC to EXTERNAL media before an upgrade

Page 92: Critical overview of HMC IBM i FSP and firmware

91

Your Turn!

How to contact me:

Pete Massiello

Email: [email protected]

Twitter: PeteM59