Advances in Phased Array Weld Inspection Scan Plan Designs Compound S-Scan for Improved Weld Flaw Detection and Sizing Chris Magruder October 26, 2016 2016 ASNT Annual Conference Long Beach, CA

Advances in Phased Array Weld Inspection Scan Plan Designs

Embed Size (px)

Citation preview

Page 1: Advances in Phased Array Weld Inspection Scan Plan Designs

Advances in Phased Array Weld Inspection Scan Plan Designs

Compound S-Scan for Improved Weld Flaw Detection and Sizing

Chris Magruder

October 26, 2016

2016 ASNT Annual Conference Long Beach, CA

Page 2: Advances in Phased Array Weld Inspection Scan Plan Designs

Advances in Phased Array Scan Plan Designs — Presentation Overview •  ASME phased array scan plan design definitions. •  Compound S-scan setup and configuration. •  Compound S-scan beam resolution. •  ASME compliance and essential variables. •  Compound S-scan calibration and configuration. •  Compound S-scan vs S-scan coverage comparison. •  Compound S-scan API 650 9%Ni cryogenic data example. •  Compound S-scan ASME B31.3 carbon steel weld data example.

Page 3: Advances in Phased Array Weld Inspection Scan Plan Designs

•  E-scan: A single focal law multiplexed across a group of elements for a

constant angle beam stepped along the probe length. •  S-scan: Set of focal laws that provides a fan-like series of beams through a

defined range of angles using the same elements. •  Compound S-scan: Set of focal laws using a fan-like series of beam

movements through a defined range of angles and elements. The compound S-scan combines the E-scan and S-scan in a single acquisition group.

Advances in PA Scan Plan Designs — ASME V Art 1 121.2 UT Definitions

Compound S-scan Azimuthal S-scan Linear E-scan

Page 4: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Select probe frequency and aperture. •  The aperture is limited by the pulser configuration and element pitch. A simple

rule of thumb is to reproduce the size of the equivalent UT probe. •  Position the probe as close to the weld as possible with respect to the first and

last A-scan position\angle that is needed for full volumetric coverage. •  Near-side wall fusion is best detected as close to perpendicular as possible.

72 degrees

Advances in PA Scan Plan Designs — Compound S-Scan Setup

Page 5: Advances in Phased Array Weld Inspection Scan Plan Designs

•  The beam resolution will determine the number of A-scans in the compound

S-scan. •  This parameter significantly affects flaw resolution, file size, and scanner speed.

72 degrees

Advances in PA Scan Plan Designs — Beam Resolution

Page 6: Advances in Phased Array Weld Inspection Scan Plan Designs

•  In the example below, all compound S-scans use the same beam aperture and

the same first and last A-scan angle and beam exit position in the wedge. •  They only differ in beam resolution, which greatly affects acoustic results. •  In addition to the S-scan beam resolution, results are also affected by the

proximity of the probe to the weld (beam spread) and probe frequency.

Advances in PA Scan Plan Designs — Beam Resolution cont.

Page 7: Advances in Phased Array Weld Inspection Scan Plan Designs

•  The beam resolution will determine the # of A-scans in the compound S-scan and

the beam-to-beam distance on the weld bevel that affects flaw height sizing. •  Flaw resolution on the weld bevel is a function of many factors, including the

sound path distance from the probe to the weld, probe frequency, aperture, focus, and beam orientation.

Advances in PA Scan Plan Designs — Beam Resolution cont.

Page 8: Advances in Phased Array Weld Inspection Scan Plan Designs

•  The compound S-scan scan plan is defined for the PA calculator or work

procedure by populating the parameters of both the linear E-scan and S-scan in ASME V Art 4 Appendix V Table V-421.

72 degrees 40-72

.5 deg

32 (1-29)

1-29

55 shear

32mm

40mm half path

PWZ1 5L60

1mm \ .9mm \ 60 \ .1mm

40-72

1

Advances in PA Scan Plan Designs — ASME Compliance

60 \ 10 \ .1

Page 9: Advances in Phased Array Weld Inspection Scan Plan Designs

•  The compound S-scan is compatible with traditional phased array sensitivity and time-of-flight (TOF) calibrations.

•  With regard to UT settings, gate position, C-scan configuration, and other functions, the compound S-scan does not require any special accommodation and is compatible with normal work procedure.

Advances in PA Scan Plan Designs — Calibration and Work Procedure

Page 10: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Although a two group S-scan strategy from the front and back of the probe is possible with any 32 or 64 element probe, use of a single compound S-scan results in less setup and calibration time, more inspection coverage, and faster analysis.

2X 40–72 at 1 degree compound S-scan 4X 40–72 at 1 degree standard S-scan

Advances in PA Scan Plan Designs — Compound S-scan vs S-scan

Page 11: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Below is a comparison of a standard and compound S-scan with the same aperture and focus inspecting a 12.7 mm V weld.

•  Detection, sizing, and characterization are similar in this thickness, but the compound S-scan index position is 8 mm closer to the weld and more easily adapted to a range of bevel thicknesses using the same setup and calibration.

Advances in PA Scan Plan Designs — Compound S-Scan vs S-Scan

Page 12: Advances in Phased Array Weld Inspection Scan Plan Designs

•  The data sample below is two-sided coverage of a 12 mm V weld. •  5L32 0.6 mm pitch probe. •  No significant loss in flaw characterization and sizing as is typical in a single

angle linear scan, also called an E-scan.

Advances in PA Scan Plan Designs — Data Example

Page 13: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Ability to use one setup configuration for a range of bevel thicknesses. •  Thin section data sample. •  4L32 1 mm pitch probe.

Advances in PA Scan Plan Designs — Data Sample 9% Ni LNG Shell

20 mm 15 mm 10 mm

Page 14: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Ability to use one setup configuration for a range of thicknesses. •  Thick section data sample.

Advances in PA Scan Plan Designs — Data Sample 9% Ni LNG Shell

25 mm 35 mm

Page 15: Advances in Phased Array Weld Inspection Scan Plan Designs

•  25 mm double V weld bevel coverage comparison of compound and standard S-scans with a 1 mm pitch, 60 element probe.

Compound S-scan Standard S-scan 2X Standard S-scan

Advances in PA Scan Plan Designs — Data Sample ASME B31.3

Page 16: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Flaw detection, sizing, and characterization meet and exceed the needs of ASME B31.3, I, V, VIII, and similar referencing codes.

31 mm V weld bevel coverage using a 32 mm aperture compound S-scan.

Advances in PA Scan Plan Designs — Data Sample ASME B31.3 cont.

Page 17: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Full volumetric coverage, including the heat affected zone (HAZ), on a 1.219 in. bevel is achieved in a single group line scan with the probe adjacent to the weld toe.

31 mm V weld bevel coverage using a 32 mm aperture compound S-scan.

Advances in PA Scan Plan Designs — Data Sample ASME B31.3 cont.

Page 18: Advances in Phased Array Weld Inspection Scan Plan Designs

•  Fewer files, faster setup and calibration, fewer acquisitions, and less time analyzing is made possible through the use of a compound S-scan.

31 mm V weld bevel coverage using a 32 mm aperture compound S-scan.

Advances in PA Scan Plan Designs — Data Sample ASME B31.3 cont.