2
information. innovation. infection control. iso-LINE Ventilation Closed Suction Catheter System for Adults US Patent 75271058B2 IapyxMedical.com Iapyx Medical P.O. Box 81634 San Diego, California 92138 USA Combines premium features for clinician ease of use and patient comfort. Iapyx Medical uses innovation and experience to develop products that protect clinicians and patients from hospital acquired infections. ORDERING INFORMATION Product # Description and Units/Box CSC-141 iSO-LINE Ventilation Endotracheal CSC, Units/Box20 21.3” Length, 14 FR Diameter CSC-142 iSO-LINE VentilationTracheostomy CSC, Units/Box20 12” Length, 14 FR Diameter To order direct from Iapyx Phone: 619-798-8270 Fax: 877-977-0110 Email: orders@iapyxmedical.com

☛ iapyx ☛ iso line Closed Suction Catheter Product Features

Embed Size (px)

Citation preview

Page 1: ☛ iapyx ☛ iso line Closed Suction Catheter Product Features

information. innovation. infection control. iso-LINE™ VentilationClosed Suction Catheter System for Adults

US Patent 75271058B2

IapyxMedical.comIapyx Medical

P.O. Box 81634San Diego, California 92138

USA

Combines premium features for clinician ease of use and patient comfort.

Iapyx Medical uses innovation and experience to

develop products that protect clinicians and

patients from hospital acquired infections.

ORDERING INFORMATIONProduct # Description and Units/Box

CSC-141 iSO-LINE Ventilation Endotracheal CSC, Units/Box20 21.3” Length, 14 FR Diameter

CSC-142 iSO-LINE VentilationTracheostomy CSC, Units/Box20 12” Length, 14 FR Diameter

To order direct from Iapyx

Phone: 619-798-8270

Fax: 877-977-0110

Email: [email protected]

Page 2: ☛ iapyx ☛ iso line Closed Suction Catheter Product Features

T-PIECE DESIGN

Dual swivel reduces torque on the circuit and airway connections

Patented slit design allows rain out to drain from t-piece reducing the possibility of oxygen flow restrictions

One-way “volcano valve” effectively cleans the catheter without restricting movement

SUCTION BODY DESIGN

CATHETER DESIGN

SHEATH DESIGN

Ergonomic thumb control valve allows for smooth and controlled suctioning of patient

Locking mechanism allows clinicians to quickly and easily view if catheter is locked

Graduation marks printed on our catheter is an iSO-LINE standard, not an additional fee

Catheter tip designed with Murphy Eye configuration to prevent occlusion

High tactile plastic sheath allows for easy catheter manipulation and prevents sheath bunching while suctioning