EMAX™ Aspiration Catheter
An efficient and effective solution for thrombus removal
Available in 5 F and 6 F
The EMAX is designed to provide an efficient and effective solution for thrombus removal. Offering excellent trackability, pushability, and aspiration volume.
DELIVERY SYSTEM• Pre-loaded Stylet provides improved pushability and kink resistance, ensuring
optimal catheter delivery in tortuous paths
• Smooth Catheter provides excellent flexibility and lumenal volume
• Hydrophilic Coating allows for easy navigation through tortuous anatomy
ASPIRATION VOLUME• Large Extraction Lumen due to shaft construction, ensures optimal aspiration rates
• Short Tip Design for deliverability and increased safety during aspiration procedure
• Large Aspiration Port allows for a higher rate of aspiration and increased aspiration volume
55.5”141 cm
2.95”7.5 cm
55.5”141 cm
2.95”7.5 cm
55.11”140 cm
Port
Port
5 F
Stylet
6 F
0.189”4.8 mm
Above measurements are taken with a guidewire in parallel to the aspiration catheter
EMAX™Aspiration Catheter
5 F Catheter Extraction Area: 0.54 mm2 6 F Catheter Extraction Area: 0.95 mm2
Guidewire Lumen
Aspiration Lumen
0.021”0.53 mm
OD 0.57 mm x ID 0.42 mm
OD 1.37 mm x ID 1.10 mm
Guidewire Lumen
Aspiration Lumen
0.01”0.26 mm
OD 0.57 mm x ID 0.42 mm
OD 1.06 mm x ID 0.83 mm
OD 0.022” x ID 0.017”
OD 0.054” x ID 0.043”
OD 0.022” x ID 0.017”
OD 0.042” x ID 0.033”5 F 6 F
Catalog Number
Compatible Guide Catheter
Compatible Guidewire
Outer Profile Suction LumenRX
LengthAspiration
PortEffective Length
DistalProximal
(Shaft + Parallel Guidewire)
Distal Proximal
VX5HI55 F
(min. ID 0.058”)(min. ID 1.47 mm)
0.014”0.36 mm
≤ 3.2 F≤ 0.042”
≤ 1.067 mm
4.44 F0.058”
1.48 mm
0.78 F0.010”
0.26 mm
2.51 F0.033”
0.838 mm
2.95”75 mm
0.189” 4.8 mm
55.5” 141 cm
VX6HI56 F
(min. ID 0.070”)(min. ID 1.78 mm)
0.014”0.36 mm
≤ 4.11 F≤ 0.054”
≤ 1.37 mm
5.34 F0.070”
1.78 mm
1.59 F0.021”
0.53 mm
3.30 F0.043”
1.10 mm
2.95”75 mm
0.189” 4.8 mm
55.5” 141 cm
TsunaMEDManufacturer: QualiMed Innovative Medizinprodukte GmbHBoschstraße 1621423 Winsen, GermanyPH: +49 4171 6578 0 FX: +49 4171 6578 11
Indications / Contraindications Indications: The EMAX Aspiration Catheter is indicated for the removal of thrombus and debris in the coronary or peripheral arteries by percutaneous suction.
Contraindications: The EMAX Aspiration Catheter is contraindicated for use in the following areas:
1. Single use only. Do not re-sterilize and/or re-use.2. These components are contraindicated in the following
lesions: • Left main trunk lesion unprotected by bypass graft or
collateral circulation. • The venous system.3. These components are contraindicated in the following
patients: • Patients who are responsive to surgical treatment • Patients with lateral distal stenosis of the stent
installed at the bifurcated lesion. • Patients with serious blood coagulation abnormality.4. The EMAX Aspiration Catheter is contraindicated in the
removal of fibrous, adherent or calcified material.
Product Specifications Platform 5 F and 6 F Thrombosis Aspiration Catheter CoatingHydrophilic coating present on distal shaft 260 mm (10.23”)
Strain Relief GuardProvides ease of pushability and prevents kinking
Rapid Exchange Segment75 mm (2.95”)
New Advanced Proximal Shaft CatheterSupports tortuous anatomy - 300 mm strengthening of the proximal tube for more proximal stiffness
Radiopaque Marker BandDistance Tip to marker 3.5 mm (0.14”)
Guidewire Compatibility0.36 mm (0.014”)
Working Catheter Length141 cm (55.5”)
Regulatory Status CE Mark Approved
Components Included • 30 ml polycarbonate locking syringes (x2)• Extension line with stopcock (x1)• 40 µm filter basket (x1)
BRO_EMAX REV. B
The EMAX Aspiration Catheter is a rapid exchange type catheter used for the removal of thrombus and debris in the coronary or peripheral arteries via percutaneous suction.
EMAX™ Aspiration Catheter
EMAX (through the lumen) vs Competitors*Pushability 5 F / 6 F
44%
44%
41%
40%
40%
27%
Pushability quotient [%]
EMAX 6 F
EMAX 5 F
Merit Medical ASAP 6 F
Medtronic Export AP 6 F
Vascular Pronto V3 6 F
Terumo Eliminate 6 F
0% 10 20 30 40 50 60 70 80 90 100%
BETTER
* Data on �le at QualiMed