20
Literature Indoor Tennis Courth BUILDING CONSTRUCTION IV SITI YAUMILIA SALSA 13.036

OSWEGO TENNIS INDOOR CENTER

Embed Size (px)

DESCRIPTION

THIS IS THE FIX MATERIAL, FOR MY PERSENTATIOR BEFORE

Citation preview

Page 1: OSWEGO TENNIS INDOOR CENTER

Literature Indoor Tennis Courth

BUILDING CONSTRUCTION IV

SITI YAUMILIA SALSA13.036

Page 2: OSWEGO TENNIS INDOOR CENTER

BACKGROUND

The Lake Oswego Indoor Tennis Center, located at 2900 Diane Drive in Springbrook Park,

offers four indoor courts and is open year round for public use. LOITC is a 4 court indoor

tennis center with 19 parking spaces. The facility was built in 1975 at a cost of $335,000. The

City‘s Charter prohibits development of any kind in Springbrook Park which limits the

expansion of the existing tennis facilities at its current location. The facility is available for all

ages and abilities, and provides a variety of recreational opportunities. These activities help build

confidence, reinforce self-esteem and encourage socialization.

Throughout the year, Parks & Recreation offers tennis lessons for players of all abilities, ages

four and up. Special activities include City League and USTA play, competitive and social ladders,

Jr. Aces, a summer youth program, junior development/match play opportunities, Special

Olympics, and daily court play.

Page 3: OSWEGO TENNIS INDOOR CENTER

LOCATION

• 2900 SW Diane Dr, Lake Oswego, OR 97035, United States

Page 4: OSWEGO TENNIS INDOOR CENTER

SITE

The LOITC is sited on 122,400 square feet of land (2.81 acres). With adjacent residential zoning of R-10, this property could be rezoned for approximately 6 to 8 residential lots while allowing space for green belts, road access, etc.

Page 5: OSWEGO TENNIS INDOOR CENTER

Site Access

• VEHICULARVehicular access to the site is mandated by Cityand County development code to be located at Atherton Drive. Because Stafford Road is designated as an arterial road, the development code requires access to be located from a feeder road (alternate means) when one exists. Access from Atherton is achievable and is considered a feeder/non-arterial street, therefore Atherton must be used as the primary vehicular access.

Page 6: OSWEGO TENNIS INDOOR CENTER

Site Access

• PEDESTRIANThe current site frontage has been improved for pedestrian access with an asphalt path/sidewalk along Stafford Road that connects to a path that leads up Atherton Drive and allows for crossings at the round- about. The proposed design will include connector paths from Stafford Road at variouspoints including the southern vehicular access point, the round-about cross-walk, and along the north access lane.

Page 7: OSWEGO TENNIS INDOOR CENTER

MASSING, SHAPE, AND SCALE

The tennis court building has been split into two buildings housing 4 courts each with a shared circulation hallway between the two buildings. The east-west building orientation was established to maximize south solar exposure for possible future photo-voltaic panels and to minimize the visual impact of the building from the neighborhood above. The building has been “pushed” into the ground to the extent possible and carved into the higher grade at the north side of the site to reduce the vertical height. The shape of the entry lobby and support spaces utilizes a simple shed roof form that signifies entry and slopes down to a more pedestrian scale.

Page 8: OSWEGO TENNIS INDOOR CENTER

EXTERIOR AESTHETICS

The character and appearance of the exterior is established from the surrounding rural feel of the Stafford Hamlet area, barn architecture, and northwest vernacular. The design utilizes various elements and features such as tapered gabled roofs, shed dormers, grey/silver metal roofing, expressed overhangs,end gable venting, and a defined building base. The main entry is identified in the design with a raisedvolume with a gable roof, storefront windows, and canopy. Materials and finishes are meant to compliment the barn vernacular with the use of fiber cement lap siding at the base of the building with board and batten fiber cement siding used on the typical walls.

Page 9: OSWEGO TENNIS INDOOR CENTER

INTERIOR LAYOUT

The interior layout was driven by the goal of creating the most efficient layout of spaces that minimizes circulation while achieving key space adjacencies that support the functional aspects of operating a public tennis center. A successfully design center will provide the staff with opportunities for passive supervision to ensure a safe environment constructed of durable materials and finishes that are appropriate for a public facility.

Page 10: OSWEGO TENNIS INDOOR CENTER

BUILDING SYSTEMS

• Heating

The 8 tennis courts, main circulation hallway, and north viewing area will be provided with a natural gas radiant heating system to maintain minimum temperatures in the winter months, similar to many other indoor tennis facilities throughout the northwest. The entry lobby, lounge/waiting, administration, restrooms, multi-purpose room, and south viewing area will have a typical split-system forced air mechanical system.

Page 11: OSWEGO TENNIS INDOOR CENTER

BUILDING SYSTEMS

• VentilationNatural ventilation will be incorporated into the design through low intake and high exhaust louvers connected to a digital control motorized damper system to allow for summer time night flushing and enhanced ventilation of the tennis courts for user comfort. The lobby area will utilize operable windows and typical mechanical ventilation.• Fire SuppressionThe facility will be equipped with a full fire sprinkler and fire alarm system.

Page 12: OSWEGO TENNIS INDOOR CENTER

BUILDING SYSTEMS

• Insulation and AcousticsThe tennis court structures will be insulated to an R-30 level at the roof and R-21 at the walls using the “simple saver” insulation system with white and green fabric vapor barrier that isspecifically designed for tennis Lighting at existing tennis center facilities and ball impact. The insulation system doubles as acoustical treatment to create a functionally quiet space for tennis.• LightingThe lighting system will be equal to Lake Oswego’s existing 4-court facility and will replicate the indirect high efficiency T-5 fluorescent fixture placed between courts and above the baseline of each court. Fixtures are ganged continuously and will be connected to occupancy sensors at each court.  

Page 13: OSWEGO TENNIS INDOOR CENTER

BUILDING ORIENTATION

The building orientation was specifically determined to take advantage of south solar exposure on the gable roofs for possible future photo-voltaic panels and/or solar hot water.

Page 14: OSWEGO TENNIS INDOOR CENTER

TECHNICAL DESIGN

The Tennis Center will be designed to meet all USTA standards with regards to court layout, critical run- off dimensions horizontally to walls, netting and columns as well as vertically to the building structure at the base line and net line. Visual distractions are reduced or eliminated through the use of solid fabric curtains and netting.

Page 15: OSWEGO TENNIS INDOOR CENTER

CONSTRUCTION

total building square footage is 68,760 square feet and includes two primary construction types for the large steel tennis structure and the smaller wood framed “clubhouse” area totaling 4,775 square feet that includes the entry, lobby/waiting, reception/control, two offices, restrooms/showers, storage/janitor closet, and a multi-purpose meeting room.

Page 16: OSWEGO TENNIS INDOOR CENTER

CONSTRUCTION

Single story pre-engineered steel frame with slab on grade foundation / floor.Steel wall and ceiling framing.• Exterior Design / Materials :Metal wall and roof panels.• Interior Design / MaterialsExterior walls are lined with plastic scrim over wall insulation. Additional vinyl curtains are hung between the steel frame columns. Ceilings are lined with vinyl scrim over insulation. Courts are enclosed with vinyl and screen curtains approximately 12’-0” in height.

Page 17: OSWEGO TENNIS INDOOR CENTER

Structure

• Seismic Resisting Lateral SystemThe lateral resisting system consists of X-braced tie rods in the long direction and steel frames in the short direction. Current code level seismic forces are higher than those the building was designed for in 1974. The building weight is light enough that it is possible wind loads would control the lateral design of the building, but the building would not meet current code prescribed seismic forces.

Page 18: OSWEGO TENNIS INDOOR CENTER
Page 19: OSWEGO TENNIS INDOOR CENTER
Page 20: OSWEGO TENNIS INDOOR CENTER