Transcript

UP

L

L

K

K

J

J

H

H

G

G

F

F

D

D

C

C

B

B

A

A

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

11 1110.9

CR-AD201

A1

CR-AD201D1

CR-AD201

B1

CR-AD201F1

E

E

01

03 03 03

03

02

02

02

03

02

04

02

06

08 03

0303030302 02 02

10

11

12

13

03

03

03

03

03

03

03

03

05050505 02 02

05 05 05 0305

II

03 03

07

15

3'-0

"

3'-0"

03

02

030303 02

02

04

02

03

03

ALIGN

ALIGN

F203

F201

F209

F208

F211

F213

F214

F215

SHEET TITLE

SHEET NUMBER

Ivy Tech Community College50 W. Fall Creek Parkway N DriveIndianapolis, IN 46208

Owner

RATIO Architects, Inc.101 South Pennsylvania StreetIndianapolis, Indiana 46204317-633-4040

Architect

CE Solutions

Structural Engineer

Mechanical / Electrical Engineer

Civil Engineer

10 Shoshone Dr.Carmel, IN 46032(317) 818-1912

Loftus Engineering, Inc.

201 South Capitol Ave. Suite 310Indianapolis, Indiana 46225(317) 352-5822

Cripe

3939 Priority Way South Dr.Indianapolis, Indiana 46240(317) 844-6777

PROJECT NO.

COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED.

SHEET ISSUE

NOT FOR CONSTRUCTION

SEAL | DATE

AV Consultant

Design 27

5366 Winthrop AvenueIndianapolis, IN 46220(317) 536-8000

7/2

3/2

018 2

:35:4

7 P

M

CR-AD101

FIRST FLOOR DEMOPLAN

17097.000

ITCC MUNCIECOWAN BLDG

Muncie, IN

3/32" = 1'-0"CR-AD101

A1 FIRST LEVEL DEMOLITION PLAN

GENERAL DEMOLITION NOTES

A THESE GENERAL DEMOLITION NOTES APPLY TO DEMOLITIONDRAWINGS.

B FIELD VERIFY CONDITIONS AND COORDINATE DEMOLITIONOR REMOVAL WORK WITH CORRESPONDING NEWCONSTRUCTION AND WITH APPROPRIATE TRADES PRIOR TOSTARTING DEMOLITION WORK. IF DISCREPANCIES AREFOUND BETWEEN CONTRACT DOCUMENTS AND ACTUALFIELD CONDITIONS, NOTIFY ARCHITECT IMMEDIATELY.

C OWNER WILL REMOVE LOOSE SALVAGEABLE ITEMS, I.E.,EQUIPMENT, FURNITURE, CABINETRY, FILE CABINETS,WALL-MOUNTED PROJECTION SCREENS, ARTWORK,PLAQUES, ETC., PRIOR TO CONTRACTOR STARTINGDEMOLITION WORK IN EACH AREA. OWNER WILL STORE ANDREINSTALL SUCH ITEMS.

D DEMOLISHED MATERIALS ARE THE PROPERTY OF THECONTRACTOR UNLESS NOTED OTHERWISE AND SHALL BEPROMPTLY DISPOSED OF OFF-SITE.

E ITEMS NOTED TO BE REMOVED AND TURNED OVER TOOWNER SHALL BE DELIVERED TO THE NEAREST EXTERIORDOOR OF THE BUILDING FROM WHICH THE ITEM WASREMOVED AS DIRECTED BY OWNER.

F REMOVE ITEMS IN THEIR ENTIRETY UNLESS OTHERWISEINDICATED. DESCRIPTION OF PRIMARY ITEMS TO BEREMOVED IS GENERAL IN NATURE, AND REMOVAL OFSECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS,ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATEDTO PRIMARY ITEMS SHALL BE INCLUDED.

G PROTECT EXISTING SURFACES TO REMAIN IN AREASADJACENT TO DEMOLITION WORK.

H REPAIR FINISHES AND SURFACES LEFT EXPOSED BYDEMOLITION OR REMOVAL OF EQUIPMENT, USING NEWMATERIALS TO MATCH SURROUNDING SURFACES. REPAIREXISTING FLOOR, BASE, WAINSCOT, WALL AND CEILINGFINISHES TO CORRECT DEFECTS EITHER CAUSED OREXPOSED BY DEMOLITION WORK OR EQUIPMENT REMOVAL.REPAIRED SURFACES SHALL BE SMOOTH ANDUNDETECTABLE UNDER FINAL FINISHES. AREAS NOTED ONTHE DRAWINGS TO BE REPAIRED OR PATCHED ARE GIVENFOR REFERENCE AND SHALL NOT BE INTERPRETED TO LIMITTHE SCOPE OF WORK.

J PATCH EXISTING FLOOR, WALL, CEILING AND ROOFCONSTRUCTION AT ABANDONED PENETRATION LOCATIONSWITH NEW MATERIALS AS REQUIRED TO RECEIVE NEWFINISHES AND TO MAINTAIN ORIGINAL FIRE RATING OFASSEMBLY WHERE APPLICABLE.

K PORTIONS OF EXISTING MASONRY WALLS NOTED TO BEREMOVED AND OPENINGS TO BE CUT INTO EXISTINGMASONRY WALLS SHALL BE REMOVED BACK TO THENEAREST VERTICAL MORTAR JOINT. PROVIDE A MINIMUMBEARING OF 8" AT EACH END FOR NEW MASONRY LINTELSAND FIELD VERIFY FINAL LENGTH. ALLOW A MINIMUM OF 4"NEW MASONRY AT JAMB CONDITIONS OR END WALLCONDITIONS OF MASONRY WALLS. REFER TO DEMOLITIONPLANS FOR LOCATIONS OF WALL, FLOOR, CEILING OR ROOFOPENINGS.

L PROVIDE SMOOTH TRANSITIONS BETWEEN FLOOR, WALLAND CEILING SURFACES PRIOR TO INSTALLING NEWFINISHES WHERE WALLS OR OTHER ITEMS ARE REMOVED.FILL FLOOR VOIDS WITH CONCRETE OR MATERIALMATCHING ADJACENT MATERIALS AND LEVEL FLOORSURFACES TO PROVIDE A SMOOTH TRANSITION FROM ONESIDE OF WALL TO THE OTHER WHERE PORTIONS OF WALLSARE REMOVED.

M ADDITIONAL FLOOR TILE MAY BE PRESENT BENEATHFINISHES IN ROOMS WITH EXISTING FLOOR TILE OR CARPET.REMOVE ALL LAYERS OF EXISTING FLOOR COVERINGS TOPROVIDE APPROPRIATE SUBSTRATE FOR NEW FLOORFINISHES.

N SELECTIVE DEMOLITION FOR INSTALLATION OF NEWMECHANICAL OR ELECTRICAL WORK SHALL BE THERESPONSIBILITY OF THE CONTRACTOR OR TRADEREQUIRING THE DEMOLITION. THIS INCLUDES, BUT IS NOTLIMITED TO, FLOOR SLAB AND PAVEMENT CUTTING FORUNDERGROUND PIPING, CORING FOR WALL AND FLOORPENETRATIONS, ROOF PENETRATIONS, ETC. REFER TOMECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONALDEMOLITION INFORMATION.

O DISCONNECT AND CAP-OFF OR REMOVE OBSOLETEEXISTING UTILITY AND SERVICE LINES PRIOR TO STARTINGDEMOLITION WORK.

P REMOVE ABANDONED UNDERGROUND UTILITIES ANDINSTALL ENGINEERED FILL.

Q IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARESUSPECTED OR DISCOVERED TO CONTAIN ASBESTOS OROTHER HAZARDOUS MATERIALS, STOP DEMOLITION ANDNOTIFY OWNER AND ARCHITECT IMMEDIATELY.

R REPAIR AND PATCH SPRAYED FIRE-RESISTIVE ANDFIRESTOP MATERIALS WHERE DAMAGED DUE TO SELECTIVEDEMOLITION ACTIVITIES TO RESTORE ORIGINAL FIRERATING UNLESS OTHERWISE INDICATED.

S THE FOLLOWING DEMOLITION WORK SHALL BE PERFORMEDAS PART OF THE WORK UNDER THE APPROPRIATE PROJECTMANUAL SECTIONS: A.) REMOVAL OF EXISTING ROOFING. B.)REMOVAL OF EXISTING WINDOWS, TEMPORARY WINDOWOPENING CLOSURES AND OPENING PREPARATION TORECEIVE NEW WINDOW UNITS.

T REFER TO WALL SECTIONS NOTED ON DEMOLITION PLANSFOR ADDITIONAL DEMOLITION INFORMATION.

KEYNOTES - DEMOLITION

01 REMOVE EXISTING STUD WALLS, FURRING, INTERIORDOORS, DOOR FRAMES, CASEWORK AND HARDWARE INTHEIR ENTIRETY, TYPICAL.

02 REMOVE PORTION OF EXTERIOR WALL TO CREATE NEWOPENING AS REQUIRED FOR NEW CONSTRUCTION. REFERTO PROPOSED PLANS FOR EXACT LOCATION.

03 REMOVE EXISTING EXTERIOR DOOR/WINDOW IN THEIRENTIRETY. REPAIR/RESTORE EXISTING OPENING TORECEIVE NEW EXTERIOR DOOR/WINDOW. PATCH/INFILLEXTERIOR MATERIAL TO MATCH ADJACENT MATERIAL ASREQUIRED.

04 REMOVE METAL PANELING IN INDICATED AREA (HATCHED)TO CREATE NEW OPENING. SALVAGE METAL PANELING FORREUSE. REFER TO DEMOLITION ELEVATIONS ANDDOOR/WINDOW SCHEDULES FOR MORE INFORMATION.

05 REMOVE EXISTING GUTTERS AND DOWNSPOUTS IN THEIRENTIRETY. EXISTING UNDERGROUND STORM PIPING TO BERE-USED WHERE POSSIBLE. COORDINATE WITH PROPOSEDPLANS.

06 REMOVE ALL PLUMBING FIXTURES, TOILET ACCESSORIESAND PARTITIONS IN THEIR ENTIRETY. SEE PLUMBINGDRAWINGS.

07 REMOVE EXISTING CONCRETE SLAB AS INDICATED(SHADED). PREPARE TO RECEIVE NEW CONCRETE ASREQUIRED TO PROVIDE FLUSH FINISH FLOOR.

08 REMOVE PORTION OF EXISTING BUILDING IN ITS ENTIRETY(HATCHED AREA). PATCH/REPAIR ADJACENT SUBSTRATESAND MATERIALS AS REQUIRED PER NEW CONSTRUCTIONDRAWINGS.

09 REMOVE EXISTING MEZZANINE FLOOR, WALLS AND ACCESSSTAIRS/LADDER IN THEIR ENTIRETY. REMOVE EXISTINGMECHANICAL, ELECTRICAL AND PLUMBING LOCATED ONMEZZANIENS IN THEIR ENTIRETY.

10 REMOVE EXISTING EQUIPMENT, INCLUDING MACHINERY, INIT'S ENTIRETY PRIOR TO CONSTRUCTION COMMENCEMENT.

11 REMOVE EXISTING INSULATION FROM UNDERSIDE OF ROOFDECK.

12 REMOVE EXISTING ELECTRICAL SERVICE PANELS ANDASSOCIATED WIRING. SEE ELECTRICAL DRAWINGS. TYPICAL.

13 REMOVE EXISTING HVAC EQUIPMENT AND ASSOCATEDDUCTWORK. SEE MECHANICAL DRAWINGS. TYPICAL.

14 REMOVE EXISTING STUCCO WALL FINISH AND ASSOCIATEDSHEATHING. REPLACE WITH VERTICAL METAL SIDING TOMATCH WALL ABOVE.

15 EXISTING CONCRETE SLAB ON GRADE TO REMAIN.COORDINATE SLAB PREP FOR NEW TOPPING SLAB PERSTRUCTURAL DRAWINGS AND SPECIFICATIONS.COORDINATE TRENCHES FOR UNDER-SLAB ELEC. ANDPLUMB. PER PROPOSED DRAWINGS AND SPECS.

16 REVIEW EXISTING ROOF PENETRATION LOCATIONS FORPOTENTIAL RE-USE. REMOVE AND PATCH ABANDONEDPENETRATIONS (APPPROXIMATELY 30 TOTAL).

17 EXISTING ROOF HATCH TO REMAIN. REMOVE LADDER ANDSALVAGE FOR RE-USE (IF POSSIBLE).

1 COWAN ROAD - 95% REVIEW SET 05/09/18

2 COWAN ROAD - BID SET 07/23/18

07/23/18

ISSUED FOR BID 07/23/18