Download pdf - GLR-SGR-E (2)

Transcript

8/10/2019 GLR-SGR-E (2)

http://slidepdf.com/reader/full/glr-sgr-e-2 1/2

Völkel Mikroelektronik GmbH Otto-Hahn-Straße 30 D-48161 Münster Tel. 02534-9731-0 Fax 02534-973110 www.voelkel.de

Load Limit Sensing Control System GLR

A machine’s efficiency is directly related to the exploitation of the diesel

engine. The load limit sensing control system regulates the decrease ofperformance. A motor overload is thus hindered and the motor outputcan be used optimally in all areas.Its versatile connection and functional options make the load limitsending control system applicable for a wide range of machines.

The GLR controller is constructed based on the hardware platformSGR. The hand terminal MT or the PC program ConDoc - Con-trol&Document®m serve to input the parameters.

GLR Connection diagram

PT1P21

20

19PT1M

SE12

SE23

SE34

SE45

SE515

SE629

SE728

SE842

PV1P

PV1M

7

6

PI

25

DG

UB14

1

PT2P35

34

33PT2A

PT2M

UPT38

37

36 GND

CH

CL

31

30

SGRGLR

PV2P

PV2M

9

8

SA1

SA2

11

13

DA 10

12FQ9P

PT3P24

23

22PT3A

PT3M

UB

CAN

RS232

27

41

PC

HP

HM

26

40

M

RxD

UMT

SG

16

17

18

32

PT1A

TxD

CE1 / AE5

FQ10

PWM

FQ9MDieselengine

Generator

Charac-teristic

Economy

Automotive

Idle

Temperature

RPMSet value1

RPMSet value 2

Potentiometer Actuator

MagnetPump 1

MagnetPump 2

Error

Target RPM

Target RPM

Actuator

Diesel J1939

8/10/2019 GLR-SGR-E (2)

http://slidepdf.com/reader/full/glr-sgr-e-2 2/2

Völkel Mikroelektronik GmbH Otto-Hahn-Straße 30 D-48161 Münster Tel. 02534-9731-0 Fax 02534-973110 www.voelkel.de

GLR Performance features

• The rotary frequency set value is set using two potentiometers, an overriding control system (PLC) ordirectly as a fixed value.

• The actual rotary frequency is measured from clamp W, via a pickup sensor or using the SAE-J1939 CAN interface.

• The diesel motor is driven via a voltage output, a PWM output, an actuator or using the SAE-J1939CAN interface.

• Errors are indicated via a switch output.

• An automatic learning function supports the recording of the characteristic diesel curve.

GLR Functions

• The entire control pattern can be individually adapted to match the machine.• The automatic idle running lowers the diesel rotary frequency in a settable period.

• The economy function and the excess temperature function both reduce the power consumption ifrequired.

• The operation mode "automotive" - automatic pump adjustment using the setting values – makesthe operation of the machine considerably easier.

SGR Hardware

The control system is protected by robustaluminium housing.

SGR Technical dataMicrocontroller: C167CR, 20 MHzProgram memory: 1 Mbyte flash EPROMData memory: 128 kByte RAMParameter memory: 64 kBit EEPROMInterfaces: RS232, CANInputs: 3 Analogue inputs 0 ... 10 V

5 Digital inputs2 Frequency inputs

Outputs: 2 Proportional solenoid

outputs up to 2 A1 Switch output up to 3A1 Analogue output 0-10V1 PWM exit 0/5V1 Actuator exit, maximum 2A

Supply: 8 ... 32 V, approx. 60 mA at 24VPlug connections: AMP 1-0967280-1, 42-pinsHousing: Black aluminium,

Protection systems: IP65, IP69KTemperature range: -25 ... 70 ° CDimensions: 152 mm x 150 mm x 56 mm

We reserve rights to make technical changes Status 04/04


Recommended