Transcript
Page 1: DOC-SPECTCA - Concrete Mat Xpress technical ......3.2 Mat structure Put on a self-adhesive flexible fiberglass mesh, the Green Cable Concrete is secured on both sides and in the middle

1

Specifications

1 Scope

ThisspecificationcoversSeriesHeatingCableMatsandtheirinstallationinconcreteforafloorwarmingapplication.

2 Applicabledocuments2.1 Thecable

Thecableset,putonself-adhesiveflexiblefibreglassmeshandsecuredbyadhesivetape,shallcomply(certified)withthefollowingstandards:

• CAN/CSA-C22.2NO.130-03,Requirementsforelectricalresistanceheatingcablesandheatingdevicesets;designationGforgeneraluseanddesignationWforwetenvironmentinCanadaandinstallationtypeCintheUSA.

• IEEE515.1–StandardforTesting,Design,InstallationandMaintenanceofElectricalResistanceHeatTracingforCommercialApplications.

3 Specifications3.1 Dimensions

Dependingontherequiredelectricalpowerandinstallationapplication,thematshallbeavailableindifferentlengthstooptimisethefloorsurfacetoheat.Makesuretoproperlyplantheproductsrequiredsincetheycannotbemodified.Thecableonthesubstrateshallhaveanominaldiameterof7/32inch(5.6mm)inordertoassureagoodimpactresistanceduringembedding.

3.2 MatstructurePutonaself-adhesiveflexiblefiberglassmesh,theGreenCable™Concreteissecuredonbothsidesandinthemiddleofthemeshbyanadhesivetape.ForthestructureoftheGreenCable™ConcretepleaserefertothetechnicaldrawingoftheConcreteMatXpress.

Writer’snotes:CAN/CSA-C22.2NO.130-03,designationGandW:Forinteriorfloorusageonly,cablesneedtobeembeddedinconcreteormortar.Wetenvironmentssuchasaceramicshowerfloororwashroom/laundryroomandinCanada,inpoolapron.IEEE515.1:Americanstandardformanufacturingandinstallationofelectricheatingcablesforcommercialapplication.

Page 2: DOC-SPECTCA - Concrete Mat Xpress technical ......3.2 Mat structure Put on a self-adhesive flexible fiberglass mesh, the Green Cable Concrete is secured on both sides and in the middle

2

3.3 CompatibilitywithinstallationsurfacesandfloorcoveringsForanapplicationrequiringaninstallationinconcrete,thematshallbecompatiblewithinstallationenvironmentandfloorcoveringsasindicatedinthefollowingtables.

Writer’snotes:Maketheselectionaccordingtothespecificproject.

Page 3: DOC-SPECTCA - Concrete Mat Xpress technical ......3.2 Mat structure Put on a self-adhesive flexible fiberglass mesh, the Green Cable Concrete is secured on both sides and in the middle

3

3.4 ElectricalspecificationsForanapplicationrequiringaninstallationinaconcreteslab,thecableshallcomplywiththeelectricalcharacteristicsasdescribedinthefollowingtable.

3.5 ElectricalvoltageThecableshallbecompatiblewithelectricalinstallationsof240VACor208VAC.

3.6 Cablesecuringsystem

Thesecuringsystemofthematwillbeaself-adhesiveflexiblefiberglassmeshwithadditionalanchorsifneeded.

3.7 ControlsFLPseriesprogrammablethermostatorFLKseriesnon-programmablethermostatincorporatingaclassAcertifiedGFCI,electronic,withlowvoltagemodule,includingatleastonetemperatureprobethatneedstobefixedtotherigidinsulationorsubfloor,placedascloseaspossibletothefloorcovering.Ifembeddingintheconcreteslab,theprobemustbeinsertedinaplasticconduitprovidedforthispurpose(FLS1260T).Foraninstallationexceeding15A,usetheFLEseriesexpansionunit.

Pleaserefertotheguideforinstallation.

Page 4: DOC-SPECTCA - Concrete Mat Xpress technical ......3.2 Mat structure Put on a self-adhesive flexible fiberglass mesh, the Green Cable Concrete is secured on both sides and in the middle

4

3.8 Producttobespecified Orderaccordingtothesurfacetocover.Thecablecannotbecutormodified.

• Localorroom:

• Surfacetobecovered:

• Floorcovering:

• ConcreteMatXpressmodel:

• Controls:(writedowntherequiredquantities) FLPFLKFLE

• Conduitforthermalprobe:(writedowntherequiredquantities) FLS1260T

4 Installation

• SecuretheheatingmatinaccordancetoFLEXTHERMConcreteMatXpressinstallationguide;torigidconcreteinsulation,concreteorplywoodwithitsself-adhesivemesh.

• PlacethethermostatremotesensingprobeinaccordancetoFLEXTHERMConcreteMatXpressinstallationguide.

• Donotcrossexpansionjointswithcable.

• Donotalterheatingcablelength.

• Ensurecablesdonotbunchorcross.

• Donotturnyoursystemon,norproceedwithfloorcoveringinstallation,immediatelyaftertheconcreteispoured.Thesystemcanbeoperatedonlyaftertheconcretehascompletelycured.Refertotheinstructionsofyourconstructionprofessionaltoverifythecuringtime:thiscuringperiodisessentialsothattheconcretereachesitsfullhardness.

• Pleaserefertotheinstallationguideforcompleteinstructions,availablewiththeproductandonourwebsitewww.flextherm.com.

Writer’snotes:Duetoitsspecificdimensions(fixedwidthof24”andstandardlength),thematcannotfitaroomprecisely.Forthisreasonandtopreventtheinstallerfromhavingtoremovethecablefromthemattoinstallitlikearegularcable(withnoinstallationgauges)werecommendchoosingamatthatdoesnotexceed90%oftheavailableheatingsurface.

Page 5: DOC-SPECTCA - Concrete Mat Xpress technical ......3.2 Mat structure Put on a self-adhesive flexible fiberglass mesh, the Green Cable Concrete is secured on both sides and in the middle

5

5 Application

6 Qualityassurance 6.1 Warranty

TheConcreteMatXpressshallbeara20yearlimitedwarrantyagainstanymanufacturingdefectwhenit’sinstalledinconformitywiththeinstallationguide.

Pleaserefertothecompletewarrantycardavailableintheinstallationguideincludedwiththeproductoronourwebsitewww.flextherm.com.

6.2 GeneralEachproductisinspectedatthesource,duringmanufacturingandattheend,inordertoensurecompliancewiththepresentspecification.

6.3 Productmanufacturinghistory Everyproducthasauniqueserialnumberthattracestheproductmanufacturinghistory.

6.4 RepairsThecablecanberepairedifit’sdamagedduringoraftertheinstallationandis5inchesorlessfromthefloorcoveringsurface.ContactourcustomerserviceforadiagnosisandarecommendationforatechnicianwhoisqualifiedtorepairFLEXTHERMheatingcables.

7 PackagingTheproductisshippedinaboxclearlyidentifiedwithitscontents.Eachboxshallinclude• Onerollofheatingmatandanchors;• Installationinstructionsincludingtestingproceduresduringinstallation.

Eachrollhasasealinordertoensuretheintegrityoftheproduct.

8 LexiconSpacing:distancebetweentwoadjacentstrandsofcable.

CableSecuringSystem:systemtobeusedtosecurethecabletothemesh(aspersection3.6).

SeriesHeatingCableSets:combinationofheatingcableandacoldleadtoconnectthecabletoelectricalsource,assembledbysupplier.

1.Insulation

2.Concreteslab/plywood

3.ConcreteMatXpress

4.Concretetopping

5.Adhesive

6.Floorcovering


Recommended