CYTOSTRETCH DEVICE: A STRETCHABLE MICRO-ELECTRODE ARRAY IN MULTI-WELL PLATE FORMAT.

Delft University of Technology

Cytostretchisamodularpla*ormthatcanbecustomizedfordifferentOrgan-on-Chip(OOC)models.Thisisbasedonconven5onal semiconductormicro-fabrica5on.Thedevicecanbeused tomechanically s5mulatecardiomyocytes invitro.Moreover,Cytostretchisprovidedwithamicro-electrodearray(MEA).Herewepresentthelatestresultstowardsthe industrializaDon of the Cytostretch plaEorm realized in the framework of the European InForMed project. TheproducDon version allows for parallel screening, and is compa5ble with standard readout equipment. Finally, themolded package, fabricated with a film assisted molding technology, comprises the plasDc well where thecardiomyocytes are cultured and it isolates electrically the interconnecDon between the MEA and the PCB duringincubaDon.Thebiocompa5bilityofthenewmoldedpackagewasprovenbyseedingonitiPSC-derivedCardiomyocytes.

Mul5-wellplate-  Moldedwells(Epoxy)-  Alllowsparallelscreening;-  CompaDblewithopDcalinspecDon;-  Suitableforinterfacingwithavailableread-outsystems.

Chip-Silicon-basedmicrofabricaDon;-Includecellcultureenvironment;-EquippedwithMEA.

Microelectrodearray-  12TitaniumNitrideelectrodes;-  EmbeddedinstretchablePDMSfoil;-  Itcanbecombinedwithasetofmicro-groovestoinducecellalignment.

MoldedPackage

PCB

MetalLine

Electrode

Micro-Groove

SiliconSubstrate

PDMSfoil

MOLDED PACKAGING

MicrofabricatedChip

FreshFimIntake FilmVacumForming

PCBLoading MoldClosing

CavityFilling OpeningandUnload

FILMASSISTEDMOLDINGGoal:TestthebiocompaDbilityofnewlydevelopedCytostretchpackagingmaterialswithPluricyte®Cardiomyocytes;Readout:MonitorcellandmonolayerappearancewithlightmicroscopyandverifybeaDngofcardiomyocytesusingcalciumdye.Pluricyte®CardiomyocytesinMolding-compound(G700LTD)precondi5onedmedia:

Lower cell density in the cells culture in precondiDonedmedium. Calcium transients were observed in all condiDonssuggesDngcellsarebeaDng.

ControlPlate Precondi5onedMedium

Lower cell density was observed in the cell culture on the Cytostretch device. While the cardiomyocytesappeared normal, no calcium transients were observed. Future tests will invesDgate the causes (maturity/funcDonality/..).

Pluricyte®CardiomyocytesonCytostretchaRer7days–Moldingcompound:EME-G770HPTypeA

Two different molding compounds have been tested:G700LTDand:EME-G770HPTypeA.