Transcript
Page 1: Application 235 EN - KROHNE · the foam is given its taste and colour through the inline dosing of additives. Then, the foam leaves the machine and is formed into the required shapes,

In line aromatisation of foam in the manufacture of confectionery

•Continuousinlinedosingofflavourandcolouringtofoambasemass•Stablecompositionoftheproduct•Highlevelofrepeatability,eveninthecaseoffluctuatingconsumption

1. BackgroundAswellaslicorice,productsmadefromfruitgum,suchasjellybabies,arefirmfavouritesinsweetshops.Dependingonthetypehowever,suchsweetseithercontainsweetfoamorevenaremadeentirelyofsweetfoam.ThisisthecasewithmanyoftheproductsfromtheMEDERERSußwarenvertriebsGmbHCompanyinFürth,whichmarketsitsproductsunderthebrandnameTrolli.Thesweetscanconsistofseverallayerswheretypically,thelowerlayerismadeoffoamandthetoponeoffruitgum.Oneexampleofthisisthewellknow"Sourapplerings"fromTrolli.

2. Measurement requirements

Tostartwith,thefreshfoamisproducedinaspecialmixmachineandthenaerated.Followingthis,thefoamisgivenitstasteandcolourthroughtheinlinedosingofadditives.Then,thefoamleavesthemachineandisformedintotherequiredshapes,e.g.bears,frogsorringsintheso-calledMogulmachine,bybeingdosedintostarchfilledmouldboards.

3. KROHNE solution

Thatthefoamgetstherequiredflavouringandcolouring,magnetic-inductiveandCoriolismassflowmetersaredeployedoneachline.AnOPTIFLUX6000DN25measuresthevolumeflowofthefresh,stilltastelessfoamasitcomesoutofthemixmachine.Atthesametime,variousadditives,namelythecolouring,citricacidandaromasaremeteredin.

APPLICATION REPORT Food & Beverage

Application 235 EN.indd 1 04.08.2010 17:48:58 Uhr

Page 2: Application 235 EN - KROHNE · the foam is given its taste and colour through the inline dosing of additives. Then, the foam leaves the machine and is formed into the required shapes,

©KROHNE08/2010-235

-Su

bjecttoch

ange

with

outn

otice.

Withthreeofthematerialsontheotherhand,OPTIFLUX6000withsmallernominalDNdiameters(2.5and4)areusedforthemeasurement.OnematerialdoesnothavesufficientconductivityandforthatreasonismeasuredusingasmallCoriolisOPTIMASS3000deviceinDN3.

Becauseofthedifficultinstallationconditionsinthedispensingsystem,themeasurementsystemsweredeliveredasaremoteversion.Thesignalconverterswereinstalledas19"rackversionsinaseparatecabinet.TheconnectiontothecontrolsystemwasrealizedthroughaProfibusDPcommunication.

4. Customer benefits

TwosystemsofthistypewerebuiltbytheHansaIndustrieMixerCompanyandinstalledandcommissionedatMedererinFürth.Eventhoughmeasuringfoamwithahighaircontentisnoteasy,theflowmetersareworkingtothecompletesatisfactionofthecustomer.Inspiteoftheveryrestrictedspaceavailablefortheinstalltionof16measuringdevices,thesystemoffershighlevelsofrepeatabilityandaccuracy.

5. Products used

OPTIFLUX 6300 R• Electromagneticflowmeterforhygienicapplications• Separatesignalconverterforinstallationina19"rack• NominalwidthrangefromDN2.5-DN150• Vacuum-resistantliner,evenwithhightemperaturechanges

OPTIMASS 3300 R• Coriolismassflowmeterforverysmallquantities• Recordsmassflowvolumesofjustafewgramsperminute• Secondarypressurecontainmentforhighsafety

Inline metering: main flow with OPTIFLUX 6000 DN 25; the flavours are metered in through the side-mounted valves.

Measurement of the metered flavours using OPTIFLUX 6000 and OPTIMASS 3000.