Flushlok II is a 4 1/2" or 5 1/2" deep system with a 1 3/4" sightlineThermally brokenScrew spline or shear block fabricationSame gasket used on interior and exteriorTrim flush glazed appearanceConcealed weepsReadily available from stock
Storefront, punched openings, or ribbon windowsSingle spanIntegrated entrance framing to allow Pittco standard entrancesor other speciality entrances to be incorporated
FOR SPECIFIC PRODUCT APPLICATIONS PLEASE CONTACT YOUR PITTCO REPRESENTATIVE
SYSTEM PERFORMANCEDescription Test Method Allowed Achieved Test Report
Structural ASTM E 330 N/A 20 psf 14-17
Air ASTM E 283 0.06 cfm/sq ft @ 6.24 psf 0.03 cfm/sq ft @ 6.24 psf 14-17
Water (Static) ASTM E 331
AAMA 501.1
None @ 4 psf
None @ 4 psf
None @ 10 psf
None @ 10 psf
14-17
14-17
CRF AAMA 1503 N/A 57* 14-19
U Value
AAMA 1503 N/A 14-190.59*
Water (Dynamic)
* 1" IGU (1/4-1/2-1/4) Clear Annealed Glass, Air Filled, Aluminum Spacer.
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FEATURES
1
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
BLANK PAGE
2
EXPLODED VIEWS PAGE 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4 SIZE DETAILS PAGES D1 TO D3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WINDLOAD CHARTS PAGES S1 TO S9. . . . . . . . . . . . . . . . . . . . . . . . . . . . DEADLOAD CHARTS PAGE S10. . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION PROPERTIES PAGE S11. . . . . . . . . . . . . . . . . . . . . . . . . .
ENTRANCE DETAILS PAGE D4. . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRODUCT DESCRIPTION PAGES 4 to 8. . . . . . . . . . . . . . . . . . . . . . . . .
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
INDEX
3
BASIC USES / RELATED USESFraming is designed for flush glazed, front loaded storefront assemblyVertical mullions are open back aluminum members, with solid face and flush closure side plates forming tubular members for use on singlespansHorizontal mullions are of hollow aluminum with removable glazing stopsCorners are configured for 90 degreesGlazing is insulating glass unit or single pane with adaptersGlass may be transparent, opaque, or decorative typesFraming is intended for one story applicationsFramed assembly may be fitted to most rigid and stable framed opening assemblies
PRODUCT ATTRIBUTES AND CHARACTERISTICSAluminum frame members are thermally brokenFraming and glazing stops are designed for glass and panelsWind pressure resistance and pressure equalization are standard within the frame assemblyWeep containment and condensate water collection and drainage to the exterior at concealed weeps are standardEconomical fabrication (as little as two framing members required per project)Integral door frames are available
SELECTION CRITERIAQuality, economy, and good performance are provided at a reasonable costFraming is designed for Interior or exterior environments
APPLICABLE STANDARDS, RELATED REFERENCESAA (Aluminum Association) - Designation System for Aluminum FinishesAAMA SFM-1-87 - Aluminum Storefront and Entrance ManualAAMA 501.1-05 - Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors using Dynamic PressureAAMA 611-98 - Voluntary Specification for Anodized Architectural AluminumAAMA 1503-98 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors, and Glazed Wall SectionsAAMA 2604-05 - Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on AluminumExtrusions and PanelsAAMA 2605-05 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings onAluminum Extrusions and PanelsASTM A123/A123M - Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and PlateASTM B209M - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate [Metric]
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
PRODUCT DESCRIPTION
4
ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and TubeASTM B221M - Standard Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles, and Tube [Metric]ASTM E283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under SpecifiedPressure Differences Across the SpecimenASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static AirPressure DifferenceASTM E331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air PressureDifference
QUALITY, TESTS, CERTIFICATIONS, AND APPROVALSAir Infiltration: Maximum leakage of 0.03 cfm/sq ft. when measured in accordance with ASTM E283 at a test pressure of 6.24 psfStatic Water Leakage: No uncontrolled leakage, when measured in accordance with ASTM E331 at a test pressure difference of 10.0 psfDynamic Water Leakage: No uncontrolled leakage, when measured in accordance with AAMA 501.1 at a test pressure difference of 10.0 psfStructural Performance: Maximum deflection less than 1/175 of the span length and no damage to the assembly, when measured in accordancewith ASTM E330 at a test pressure of 20 psf
Insulation U-Factor: 0.59 BTU/hr/sq ft/degrees F when measured in accordance with AAMA 1503
PACKAGING, HANDLING, AND PROTECTION INSTRUCTIONSPackaged in specially designed heavy cartons or shipped pre-fabricated and assembled
SPECIAL WARRANTYOne (1) year
LIMITATIONSFraming is limited to applications of one story in heightNot intended for continuous members for multiple floor applicationsExterior glazed only
SAFETY PRECAUTIONSNormal precautions required
AVAILABILITYFraming is available in all regions of USA - refer to Internet web site for locations and addresses of distributors
COSTVaries with elevation, configuration and finish desired
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
PRODUCT DESCRIPTION
5
PRODUCT PROPERTIES
MATERIAL AND DESIGN
Aluminum: 6063-T6 alloy and temper, to ASTM B221 or ASTM B221M
Fasteners: Stainless steel, or zinc plated carbon steel
Perimeter Anchors: Aluminum, or steel that will be isolated from aluminum components
Glazing Gaskets: Ethylene Propylene Diene Monomer (EPDM) rubber with non-stretch cord
Glass Stops: Snap-in type
SHAPE AND DIMENSIONSFrame Size: 1-3/4 x 4, 4-1/2, or 5-1/2 inchGlass Edge Bite: 1/2 inch
Glazing Thickness Accepted: 1/4 inch and 1 inch
SHOP FABRICATION AND ASSEMBLY
Provide for flush glazing on all sides with no projecting stops
Configurations:
Two-piece snap together mullions
Solid tubular mullions, assembled to specially designed shear block clips
Accessories:
Open Back Perimeter Members
Integral Door Frames
Flashing, Subsills
Standard aluminum reinforcing
COLORS AND TEXTURES
Architectural anodic coating, in accordance with AAMA 611;
o Aluminum Association Designation.
AA-M10C22A31 - Class II - (Pittco #42 Clear)
AA-M10C22A41 - Class I - (Pittco #43 Clear)
AA-M10C22A44 - Class I - (Pittco #59 Champagne)
AA-M10C22A44 - Class I - (Pittco #60 Light Bronze)
AA-M10C22A44 - Class I - (Pittco #61 Medium Bronze)
AA-M10C22A44 - Class I - (Pittco #62 Dark Bronze)
AA-M10C22A44 - Class I - (Pittco #63 Black)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
PRODUCT DESCRIPTION
6
o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2604, High PerformanceOrganic Coatings on Aluminum
o Type: Factory Applied, High Performance, 50% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, andapplied by Paint Manufacturer's Warranty-Approved Applicator
o Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminum
o Specify color code, e.g. UC 40577(Duranar Black)
o Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA Specification 2605, Superior PerformingOrganic Coatings on Aluminum
o Type: Factory Applied, High Performance, 70% Polyvinylidene Fluoride (PVDF) Coating formulated by a licensed paint manufacturer, andapplied by Paint Manufacturer's Warranty-Approved Applicator
o Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic surface soils, remove residual oxides,followed by a Chrome Phosphate or Chromate Coating to ensure adhesion to the aluminum
o Specify color code, e.g. UC 40577(Duranar Black)
PREPARATION WORKEnsure openings are of proper size, and are plumb, square, level and in the proper location and alignment
INSTALLATIONAlign installed assembly plumb and level, free of warp or twistMaintain dimensional tolerances, aligning with adjacent workSeal joints between framing and building structure watertightFollow guidelines in Pittco Fabrication, Sealant and Erection Brochure
START-UP AND OPERATIONNot Applicable
OWNER'S MAINTENANCE INSTRUCTIONSWash surfaces with warm water and mild soap; wipe clean, at least once a year
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
PRODUCT DESCRIPTION
7
Corporate IdentificationPittco Architectural Metals, Inc
1530 Landmeier RoadElk Grove Village, Illinois 60007Tel: (847) 593-3131Fax: (847) 593-9946Toll-Free: (800) 992-7488Internet: http://www.pittcometals.comE-mail: [email protected]
Technical Services AvailableToll-Free: (800) 992-7488
Classification and FilingMasterFormat
Subset of Section 08410 - Metal Framed StorefrontsUniFormat
Section B2030 - (exterior entrance frames) or C1020 (interior entrance frames)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
PRODUCT DESCRIPTION
8
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
EXPLODED VIEW
9
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
BLANK PAGE
10
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
14-474 (JAMB)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-552 (MULLION)14-553 (MULLION FILLER)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-474 (HEAD)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-414 (HORIZONTAL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-474 (SILL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)15-566 (SUB-SILL)
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
14-474 (JAMB)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-414 (MULLION)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-474 (HEAD)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)14-419 (SHEAR BLOCK)
14-414 (HORIZONTAL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)14-419 (SHEAR BLOCK)
14-474 (SILL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)15-566 (SUB-SILL)14-419 (SHEAR BLOCK)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
4 1/2" SystemTYPICAL FRAMING DETAILS
D1DETAILS
3
4
5
1 2
SCREW SPLINE SHEAR BLOCK
2VERTICAL
1JAMB
3HEAD
4HORIZONTAL
5SILL
14-494 (JAMB)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-572 (MULLION)14-573 (MULLION FILLER)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-494 (HEAD)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-418 (HORIZONTAL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-494 (SILL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)15-567 (SUB-SILL)
1JAMB
3HEAD
4HORIZONTAL
5SILL
2VERTICAL
14-494 (JAMB)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-418 (MULLION)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)
14-494 (HEAD)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)14-420 (SHEAR BLOCK)
14-418 (HORIZONTAL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)14-419 (SHEAR BLOCK)
14-494 (SILL)14-439 (ISOLATOR CLIP)14-451 (EXTERIOR COVER)14-420 (SHEAR BLOCK)15-567 (SUB-SILL)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
5 1/2" System TYPICAL FRAMING DETAILS
D2DETAILS
(412" SYSTEM) (41
2" SYSTEM)
(512" SYSTEM) (51
2" SYSTEM)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
CORNER DETAILS
D3DETAILS
1DOOR HEAD
2BOTTOM RAIL
1
2
43
5
2
76
5DOOR HEAD
6DOOR JAMB
7DOOR JAMB
4DOOR JAMB
3DOOR JAMB
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
Offset Hung ENTRANCE DETAILS
D4DETAILS
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
www.pittcometals.com
14-474
14-47414-419
A
B
C
E
D
A
B
C
E
D
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S1
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
14-47414-448
14-55214-553
A
B
C
E
D
A
B
CE D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S2
14-414
14-55214-55314-547
A
B
CE D
A
B
CE D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S3
14-41414-448
14-41414-419
A
B
C
E D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
THERMAL WINDLOAD CHARTS
S4
14-41414-448
14-476
A
B
C
E
D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S5
14-49414-419
14-494
A
B
C
E
D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S6
14-57214-573
14-49414-448
A
B
C
E
D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S7
14-418
14-57214-57314-547
A
B
C
E
D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S8
14-479
14-41814-448A
B
C
E
D
A
B
C
E
D
SYSTEM ANALYSIS CRITERIA:
DEFLECTION LIMITS: L/240 + 1/4" FOR SPANS GREATER THAN 13'-6"
CODES AND SPECIFICATIONS VARY, NO SINGLE LITE OF GLASS SHALL DEFLECT MORE THAN 3/4"
L/175 FOR SPANS LESS THAN 13'-6" OR 3/4"
LATERAL BRACING OR HORIZONTAL MULLION SPACING: 48" O.C. (MAXIMUM)SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6
REINFORCEMENT IS ADDITIVE TO ALUMINUM MULLIONS (NOT COMPOSITE SECTIONS)
A = 15 PSFB = 20 PSFC = 25 PSFD = 30 PSFE = 40 PSF
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
WINDLOAD CHARTS
S9
A = SETTING BLOCKS AT 1/8 POINTSB = SETTING BLOCKS AT 1/4 POINTS
14-414
14-418
AB
AB
SYSTEM ANALYSIS CRITERIA:
SECTION EVALUATED PER 2005 ALUMINUM DESIGN MANUALSIMPLE SPAN CONDITION
ALUMINUM: 6063-T6DEADLOAD LIMITATIONS ARE BASED UPON 1/8" MAXIMUM ALLOWABLE DEFLECTION
HEIGHT IN FEET ON CHART IS GLASS HEIGHT ABOVE HORIZONTAL
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
FLUSHLOK II
SEPTEMBER 2014
DEADLOAD CHARTS
S10
www.pittcometals.com
ARCHITECTURAL METALS, INC.
FLUSHLOK II
SEPTEMBER 2014
SECTION PROPERTIES
S11