58
www.sena.com www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

Embed Size (px)

Citation preview

Page 1: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

SENA

Dec, 2004

HelloDevice Super seriesSS100/110/400/800

One-Stop Solution in Device Networking

Page 2: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

2

www.sena.comwww.sena.com

Contents Overview Configuration Ways

Text-based Interface Web-based Interface

Features Operation Modes TCP/UDP Multiple Remote Hosts Security PC Card Support Data Logging Event Handling SNMP Dynamic Domain Name Customization Support

Case Studies Door Access Application (Customized) Medical Application (Customized) Bridge Monitoring System

Page 3: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

3

www.sena.comwww.sena.com

Overview (1)• Linux-based Open platform (kernel 2.4.2)• Supports 1/4/8 serial port (RS232/422/485)• 1 PCMCIA slot

– ATA flash memory, LAN/WLAN, PSTN/CDMA Modem• Flexible host mode mode

– TCP/UDP single/multi-session support– Primary/Secondary host support

• Powerful Security– Industry-standard encryption support

• SSL v3, and TLS v1– Encryption algorithm support

• 3DES, and RC4• Flexible customization

– Linux CLI with development environment– Source file add/modify/compile/link in 1MB user space– Web customization

Page 4: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

4

www.sena.comwww.sena.com

Overview (2)

Remote Host Host (SS) Device

• LAN

• Wireless (802.11b)

• PSTN

• Mobile (CDMA)

• RS-232

• RS-422

• RS-485

Any device with serial interface

Connections

Page 5: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Configuration Ways

1. Text-based Interface2. Web-based Interface

Page 6: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

6

www.sena.comwww.sena.com

1. System Console2. Telnet (port 23) or3. SSH (port 22)

Text-based Interface

Privileges

• Admin user can access and edit configuration parameters.

• Root user can have full control on SS via CLI, in addition to access and configuration rights.

Page 7: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

7

www.sena.comwww.sena.com

Web-based interface using web browsers such as IE, Netscape and Opera

Web-based Interface

Page 8: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Features

1. Operation Modes2. TCP/UDP Multiple Remote Hosts3. Security4. PC Card Support5. Data Logging and Event Handling6. SNMP7. Dynamic Domain Name8. Customization Support

Page 9: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

9

www.sena.comwww.sena.com

Operation modesVarious operation modes

•TCP/UDP

device

Remote host

•modem emulation

modem

DTE

TCP/UDP socket

Remote host

TCP socket

DTEmodem

Remote host

TCP socket

•Dial-in/out mode

Page 10: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

TCP/UDP Multicasting

1. Overview2. Configuration3. Connection4. Application Diagram5. Application Areas

Page 11: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

11

www.sena.comwww.sena.com

Overview• SS supports an enhancement transmission method "TCP/UDP

multicasting", which transmits serial device data to multiple hosts simultaneously.

• Max. 32 hosts (incoming+outgoing) per one port allowed.

• Max. 16 outgoing connections (registered remote hosts) per one port allowed

• Each registered TCP host can have a backup host

• UDP host mode does not support backup host since there is no way to check status of primary remote host.

• Multicasting feature is very useful in application areas where user needs to transmit a message to several display signboard devices simultaneously.

Page 12: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

12

www.sena.comwww.sena.com

Configuration• Access the SS web interface

– Choose Serial port --> Configuration --> Port # --> Remote host configuration

Page 13: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

13

www.sena.comwww.sena.com

Connection

Page 14: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

14

www.sena.comwww.sena.com

Application Diagram

Page 15: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

15

www.sena.comwww.sena.com

Application AreasApplications which require Multiple data transmission include:

• LED Signboard,• Electronic Metering,• Any customer requiring Multiple data transmission.

Page 16: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Security

1. SSL Encryption: Overview2. SSL Encryption: Configuration3. SSL Encryption: Connection4. Other Security Features5. Application Areas

Page 17: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

17

www.sena.comwww.sena.com

SSL Encryption: Overview

• SSL creates a secure connection between a client and a server, over which any amount of data can be sent securely.

• By setting the cryptography method as one of SSLv2, SSLv3, SSLv3 rollback to v2 or TLSv1, the Super Series can communicate with other device supporting SSL/TLS cryptography method in encrypted sessions.

• SSL configuration settings are available only when the host mode is set to TCP or Modem Emulation mode.

• SSL works by using a private key to encrypt data that's transferred over the SSL connection.

Page 18: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

18

www.sena.comwww.sena.com

SSL Encryption: Configuration• Access the SS web interface

– Choose Serial port --> Configuration --> Port # --> Host mode configuration

– Choose Serial port --> Configuration --> Port # --> Cryptography configuration

Page 19: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

19

www.sena.comwww.sena.com

SSL Encryption: Connection

• Run SSL or TLS client application– openssl s_client –connect 192.168.0.2:6001 –ssl3

Page 20: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

20

www.sena.comwww.sena.com

Other Security Features Serial data encryption

3DES, RC4

Static Key encryption

Secured Web interface

HTTPS

IP filtering

serial port based IP filtering

box based IP filtering

Secured file uploading

SCP

Page 21: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

21

www.sena.comwww.sena.com

Application AreasApplications which require more secure communications include:

• Financial,• Retail/POS,• Government,• Medical, and• Any customer requiring enhanced security to protect sensitive

information.

Page 22: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

PC Card Support

1. Overview2. CF Memory card configuration3. Modem card configuration4. LAN card configuration5. WLAN card configuration

Page 23: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

23

www.sena.comwww.sena.com

Overview

• PC card types that can be added to the SS include a serial modem, compact-flash card, wireless LAN card, and a network LAN card.

Page 24: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

24

www.sena.comwww.sena.com

CF Memory card configuration• Access the SS web interface

– Choose PC Card --> Configuration

Page 25: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

25

www.sena.comwww.sena.com

Modem card configuration• Access the SS web interface

– Choose PC Card --> Configuration

Page 26: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

26

www.sena.comwww.sena.com

LAN card configuration• Access the SS web interface

– Choose PC Card --> Configuration

Page 27: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

27

www.sena.comwww.sena.com

WLAN card configuration• Access the SS web interface

– Choose PC Card --> Configuration

Page 28: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Data Logging and Event Handling

1. Overview2. Data Logging Configuration3. Data Event Handling Configuration4. Data Event Handling Test

Page 29: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

29

www.sena.comwww.sena.com

Overview

• The SS can capture all system and port data, and save it into a log file. This buffer can be viewed from the web, saved to memory, or saved to a Flash Card, syslog server or NFS server.

• System logs track events such as logins, authentication failures, system configuration changes, and more.

• Port logs document the data flow through the SS serial ports.

• In addition, the SS can be configured for system alerts and notifications. It can send email messages when an alarm message is detected in the serial port data.

• The SS uses SMTP for sending email notifications and SNMP for trap alerts.

Page 30: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

30

www.sena.comwww.sena.com

Data Logging Configuration• Access the SS web interface

– Choose Serial port --> Configuration --> Port # --> Port logging

Page 31: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

31

www.sena.comwww.sena.com

Data Event Handling Configuration• Access the SS web interface

– Choose Serial port --> Configuration --> Port # --> Port logging

Page 32: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

32

www.sena.comwww.sena.com

Data Event Handling Test• Event Handling via SNMP browser and SMTP email

Page 33: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

SNMP

1. Overview2. Configuration3. Connection

Page 34: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

34

www.sena.comwww.sena.com

Overview

• SS supports SNMP that provides status and performance of connected serial devices through their Ethernet connections.

• Applications such as NMS or an SNMP browser can exchange information with the SS.

• The SS supports SNMP authentication, Login, and Link up traps.

• The SS supports both versions 1 and 2 of the SNMP protocol and delivers the System and Port alerts as traps.

Page 35: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

35

www.sena.comwww.sena.com

Configuration• Access the SS web interface

– Choose Network --> SNMP configuration

Page 36: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

36

www.sena.comwww.sena.com

Connection• Authentication, Login, and Link up traps in Kiwi SNMP browser

Page 37: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Dynamic Domain Name

1. Overview2. Configuration and Connection

Page 38: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

38

www.sena.comwww.sena.com

Overview

• Dynamic DNS Protocol enables users to access the SS via a domain name for floating IP environments such as DSL line and DHCP.

• To use this service, users must set-up an account in Dynamic DNS Network Services and add domain name, user name and password on the SS DDNS configuration page.

• Whenever user reboots the SS in floating IP environments, it sends updated IP address to Dynamic DNS Network Services.

Page 39: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

39

www.sena.comwww.sena.com

Configuration and Connection• Access the SS web interface

– Choose Network --> Dynamic DNS configuration

• Access the SS web interface and use domain name• For e.g., ismdemo.dyndns.biz

Page 40: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Customization Support

1. Overview2. User Web Customization - HTML pages3. User Web Customization – CGI & Java pages4. Serial Filter Application

Page 41: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

41

www.sena.comwww.sena.com

Overview• Web customization options

– Plain HTML files– CGI written in C

• User application implementation– Filter applications in C– Other applications in C or shell scripts

• To quickly develop custom applications that run on the HelloDevice Super Series, SDK (Software Development Kit) is needed.

• SS SDK is a 256MB CF card composed of executable binaries (including gcc), header files, and library files.– Executable binaries run on SS (MPC855T Linux)– Header files and Library files are compatible with SS platform

• With SS SDK, users can compile their own C/C++ source code to run on SS without installing cross-compile utilities on their PC.

Page 42: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

42

www.sena.comwww.sena.com

• If you are using Windows, using SCP (secure copy protocol) client tools for Windows will be handy for file transfer from/to SS

• Winscp (GUI)– Download @ http://winscp.sourceforge.net/eng/– Install as other applications

• Pscp (command line interface)– Download pscp.exe @

http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html

– Copy pscp.exe into C:\Windows directory

Preparation

User Web Customization - HTML pages (1/3)

Page 43: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

43

www.sena.comwww.sena.com

• Prepare index.html file and other related files (e.g. index.html and webtest.swf)

• Just copy the files to SS, /usr2/usrweb directory using SCP tools (e.g. winscp) and it will work!

Running User HTML file

User Web Customization - HTML pages (2/3)

Page 44: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

44

www.sena.comwww.sena.com

User Web Customization - HTML pages (3/3)

Browsing SS User Web Pages

Page 45: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

45

www.sena.comwww.sena.com

[email protected]:~# editconf

------------------------------------------------------------------------------ Welcome to SS-110 configuration page … IP mode: DHCP IP address: 192.168.0.15------------------------------------------------------------------------------ Select menu: 1. Network configuration … <Enter> Refresh---> 3------------------------------------------------------------------------------ PC Card configuration------------------------------------------------------------------------------ Currently configured PC card: (none)

Select menu: 1. Change card configuration 2. Stop the card service to disable or remove card

3. Probe a new card <ESC> Back, <Enter> Refresh---> 3 Do you want to probe a new pc card? (y/n): y

A new PC card is discovered.

------------------------------------------------------------------------------ PC Card configuration------------------------------------------------------------------------------ Currently configured PC card: ATA/IDE fixed disk card Model: SanDisk SDP 5/3 0.6 Size: 257 MB File system: ext2 …--->------------------------------------------------------------------------------ Welcome to SS-110 configuration page …------------------------------------------------------------------------------ Select menu: 1. Network configuration … 6. Exit without saving

7. Exit and apply changes 8. Exit and reboot <Enter> Refresh---> 7Are you sure to save changes? (y/n): ySaving..Configuration is saved successfullyAre you sure to apply changes? (y/n): yApplying........Configuration is applied successfully

• After recognition, SDK is mounted on /mnt/flash/ directory

User Web Customization – CGI & Java pages (1/3)

Preparation: Recognizing SDK Card

Page 46: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

46

www.sena.comwww.sena.com

• Make working directory such as /mnt/flash/work

• Copy cgi source file (e.g. ex.c) into the working directory

• Compile *.c file with the option of “–L/mnt/flash/lib” (Library path)

• Copy *.cgi binary file to /usr2/cgi-bin/ directory

• Copy index.html that has CGI link in it to /usr2/usrweb/ directory

User Web Customization – CGI & Java pages (2/3)

Compiling and Copying files

Page 47: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

47

www.sena.comwww.sena.com

[email protected]:/mnt/flash/work# cat ex.c#include <stdio.h>#include <stdlib.h>#include <string.h>

main(int argc, int *argv[]){ printf("Content-type: text/html\n\n"); printf("<html>"); printf("<body bgcolor=\"#0000C0\">"); printf("<b><font color=\"#FF0000\">This is a sample CGI page</font></b>\n"); printf("</body>"); printf("</html>\n"); fflush(stdout);}[email protected]:/mnt/flash/work# gcc -o ex.cgi ex.c -L/mnt/flash/[email protected]:/mnt/flash/work# cp ex.cgi /usr2/cgi-bin/[email protected]:/mnt/flash/work#

User Web Customization – CGI & Java pages (3/3)

Sample CGI Source file and Output

Page 48: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

48

www.sena.comwww.sena.com

Serial Filter Application (1/4)

• Users just need to write filter application only to customize serial port application rather than writing whole source code

• Typical situation for serial application customization:– Add/remove protocol

header– Periodically check serial

device

SS Serial Filter Structure

Page 49: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

49

www.sena.comwww.sena.com

• Location = /mnt/flash/sample/filter

• periodic_filter.c– Periodic query of the serial device application might

start from here

• empty_filter.c– Do nothing. Adding/removing header application

might start from here

Sample file

Serial Filter Application (2/4)

Page 50: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

50

www.sena.comwww.sena.com

• Log into the SS (Telnet or SSH)

• Copy sample file from SDK to working directory (e.g. /mnt/flash/work)

• Compile source file (Be careful with compile options)gcc -o myfilter myfilter.c -L/mnt/flash/lib –lpthread

• Copy compiled binary to /usr2 directory

• Specify filter application and arguments using configuration web or menu configuration

How to

Serial Filter Application (3/4)

Page 51: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

51

www.sena.comwww.sena.com

[email protected]:/mnt/flash/work# cp /mnt/flash/sample/filter/periodic_filter.c ./[email protected]:/mnt/flash/work# gcc -o myfilter myfilter.c -L/mnt/flash/lib [email protected]:/mnt/flash/work# cp myfilter /[email protected]:/mnt/flash/work# editconf…------------------------------------------------------------------------------ Serial port configuration - Port #1 --> Filter application------------------------------------------------------------------------------ Select menu: 1. Filter application path name: /bin/ss.filter 2. Filter application arguments: <ESC> Back, <Enter> Refresh---> 1 Enter a filter application full path name(ex: /bin/filter)---> /usr2/myfilter------------------------------------------------------------------------------ … 1. Filter application path name: /usr2/myfilter 2. Filter application arguments: <ESC> Back, <Enter> Refresh---> 2 Enter filter application arguments---> 'You will see this msg every 1 sec' 1

Sample Filter and Output

Serial Filter Application (4/4)

Page 52: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

www.sena.comwww.sena.com

Case Studies

1. Door Access Application (Customized)2. Medical Application (Customized)3. Bridge Monitoring System

Page 53: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

53

www.sena.comwww.sena.com

Door Access Application (Customized)

Page 54: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

54

www.sena.comwww.sena.com

Door Access Application (Customized)

• Target Device : RF-ID Card Reader

• Application Details:– Customer has added a user customized filtering

program that transmits only needed serial-based RF's to the management station through the SS110.

– As a result, the time that is required to process visitor’s door access requests has been dramatically minimized.

– Why SS instead of the PS?• Fast response required Local protocol parser

application is required on the SS to reduce the network traffic

Page 55: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

55

www.sena.comwww.sena.com

Bridge Monitoring System

SS110

System Architecture

Page 56: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

56

www.sena.comwww.sena.com

Bridge Monitoring System

• Target Device : Gage length deformation sensors on a Railway Bridge

• Application Details:– Long gage length deformation sensors (GPS) that are

installed throughout a railway bridge to gain actionable information from the bridge

– Why SS110? • Powerful logging capability (Syslog server)• Wireless LAN thru PCMCIA slot

Page 57: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

57

www.sena.comwww.sena.com

Medical Application

• Target Device: Medical Monitoring Device

• Application Details:– Serial based medical devices are connected to

Ethernet using the SS400/800– Medical devices are reset remotely by sending

“serial-break” signal thru the SS– “Serial-break” feature is implemented using the SS

customization feature

Page 58: Www.sena.com SENA Dec, 2004 HelloDevice Super series SS100/110/400/800 One-Stop Solution in Device Networking

58

www.sena.comwww.sena.com

Contact SENA

SENA Technologies, Inc.

[email protected]:+82-2-529-7025Fax: +82-2-573-7710Web Address: http://www.sena.com210 Yangjae-dong Seocho-guSeoul 137-130, South Korea