1
SPEC1712_SS100 ZURN.COM.AU Dimensional Data (mm) are Subject to Manufacturing Tolerances and Change Without Noce SENSAFLUSH SENSOR UNIT SS100 FLUSHING SYSTEMS Sensaflush SS100 SS100KIT PRODUCT CODES CODE DESCRIPTION Sensor Unit Installation Kit SS100KIT OVERVIEW The Zurn SS-100 utilizes current technology to provide a "hands free" flushing for urinals and cistern systems. This will reduce water usage by up to 60% over conventional cisterns while offering complete water management and hygiene control. Microwave sensors detect movement before the flush cycle is initiated. With site adjustable delayed detection time and flush duration, this is a complete water management system. ENGINEERING SPECIFICATION Power supply 204VAC/24VAC Inrush current 150VAC Amperage 6.5 AMP Maximum solenoids 3 maximum cable run 20 metres Sensing Microwave Sensing range 3.6 metres Flushing duration Adjustable Delayed flushing Adjustable After hours flushing Adjustable Minimum operating pressure 350 kPa OH THE SS100 IS NOT INCLUDED IN THE KIT THE POWER SUPPLY IS NOT INCLUDED IN THE KIT (NOT INCLUDED)

FLUSHING SYSTEMS Sensaflush SS100

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

SPEC1712_SS100 ZURN.COM.AU

Dimensional Data (mm) are Subject to Manufacturing Tolerances and Change Without Notice

SENSAFLUSH SENSOR UNIT SS100

FLUSHING SYSTEMSSensaflush

SS100 SS100KIT

PRODUCT CODES

CODE DESCRIPTIONSensor Unit Installation Kit

SS100KIT

OVERVIEW The Zurn SS-100 utilizes current technology to provide a "hands free" flushing for urinals and cistern systems.

This will reduce water usage by up to 60% over conventional cisterns while offering complete water management and hygiene control.

Microwave sensors detect movement before the flush cycle is initiated.

With site adjustable delayed detection time and flush duration, this is a complete water management system.

ENGINEERING SPECIFICATION Power supply 204VAC/24VACInrush current 150VACAmperage 6.5 AMPMaximum solenoids 3maximum cable run 20 metresSensing MicrowaveSensing range 3.6 metresFlushing duration AdjustableDelayed flushing AdjustableAfter hours flushing AdjustableMinimum operating pressure 350 kPa