Tema-VoyagerTM Multi - VMA-06, VMA-07Quick Installation GuideDocument Number: 800-20479 Rev. 1.5 January 2019
Mounting tools
One 3mm slotted screwdriver (for VMA-07 only) One T10 Torx screwdriver
MAX Power consumption (Tema-Voyager Multi with Plug ins)* : 10-30VDC: 36 W POE+: 25.5 W POE: 15.4 WAvailable current for Readers and Locks*: 10-30VDC: MAX 1500 mA @ 12V POE+: MAX 1500 mA @ 12V POE: MAX 750 mA @ 12V
Operational Temperature: -10 ~ 55°CProtection level: IP32 (inside Tema-Voyager Multi case)Outputs: 4 dry contact NC/NO 3A/30VDC.
Storage Temperature: -25 ~ 70°C
VMA-06 - Technical Specifications
VMA-07- Technical Specifications
Mount VMA-06 and VMA-07 on Voyager Multi1. Determine an appropriate mounting position for the plugs in. If you have a VMA-07 you have to plug it only on the position 1, where VMA-06 can be plugged in any of the 3 sockets' positions (in relation to the outputs to be managed).
- Position 1 drives fixed outputs 1, 2, 3, 4 - Position 2 drives flexible outputs 3, 4, 5, 6 - Position 3 drives flexible outputs 1, 2, 7, 8
2. Switch off the Voyager Multi device.3. Unscrew the cover of the Voyager Multi case and remove it.4. Plug the VMA-0x devices on the Voyager Multi board.5. Set the jumpers required to configure the use of the plug in (turn this sheet for details).6. Wire the outputs as specified in Voyager Multi Quick installation Guide.
1 2 3
What are VMA-06 and VMA-07 devices?VMA-06 and VMA-07 are plug ins used together with Tema-Voyager Multi devices. When these are plugged on the Multi board and properly configured using the related jumpers they turn the open collector digital outputs of the board in relay outputs. VMA-07 includes the connection for an input that drives the cut of the power supply of the device in case of emergency.
7. If you are using VMA-07 wire the input used to cut the POE/ POE+ internal power supply (turn this sheet for details); such wires can enter in the Multi case from the two holes located on the right of the first group of holes on the below margin on the device (see picture).
8. Close and screw the cover of Voyager Multi9. Switch on the Voyager Multi device.
MAX Power consumption (Tema-Voyager Multi with Plug ins)* : 10-30VDC: 36 W POE+: 25.5 W POE: 15.4 WAvailable current for Readers and Locks*: 10-30VDC: MAX 1500 mA @ 12V POE+: MAX 1500 mA @ 12V POE: MAX 750 mA @ 12V
Operational Temperature: -10 ~ 55°CProtection level: IP32 (inside Tema-Voyager Multi case)Outputs: 4 dry contact NC/NO 3A/30VDCInputs: 1 dry contact for emergency alarm
Storage Temperature: -25 ~ 70°C
* Tema-Voyager Multi - Consumption Verifier Tool helps in verifying the consumption of your device
Tema-VoyagerTM Multi - VMA-06, VMA-07
Door lock powered from device
VMA-06 Plug in Wiring diagram VMA-07 Plug in Wiring diagram
Door lock powered from external power supply and driven from internal relay
Possible Relay Output modes
Use of Emergency Input to cutthe door lock power
Direct powering of the door lock
For further details on the Tema-VoyagerTM Multi installation process refer the Tema-VoyagerTM Multi Installation Manual, located it in the following repository:https://extranet.honeywell.com/HBS/EBI/EBIHOME/Pages/default.aspx (EBI home > Product Manuals > TEMA Device Installation Manuals).
The information contained in this manual can be modified at any time without notification.Manufacturer single contact point: Honeywell S.r.l. Via Philips,12 20900 MONZA (Italy)
VMC-xx Mother board Wiring diagram
Configurable I/O
Reader 1 Out 1
J2
Reader 2
Output 1/2 relay selectors(Factory preset: No relay)
Output1: P11, P12Output2: P09, P10
P12
Out 2 In 1 In 2
Fixed I/O
Line 3 Line 4
Line 1 Line 2
Configurable I/O
Reader 3 Reader 4
Out 3 In 4
In 3
Fixed I/O
Line 6 Line 5
Line 8 Line 7
Out
Output 3/4 relay selectors(Factory preset: No relay)
Output3: P07, P08Output4: P04, P05
J4
EGND - +12345678
1 2 3 4 5 6 7 81 2 3 1 2 3 1 2 3
123123123 12
1 2
This picture shows the factory default jumpers positions(to use relay move jumpers on the opposite position: from to )
TB7123
+ 1
2V
OU
T 1
Door Lock
Using Fixed Output 1 Relay Normally open
P13 P26
Output on line 3/4relay selectors(Factory preset: No relay)
Line3: P13, P14 Line4: P03, P26
P10
P09
P11 TB7
TB8
TB1 TB3TB5
TB6 TB2 TB4
Output on line 1/2 relay selectors(Factory preset: No relay)
Line1: P25, P27Line2: P19, P20
P14 P03
P25 P20
P27 P19
P08
P07
P04
P05
TB15TB09
TB16
TB13
TB14
TB11
TB12TB10
P21 P24
P22 P23
P15 P18
P16 P17
Refer to Technical specification for the MAX current powered in relation to the power source used.
P12
P10
P09
P11
TB8
8 6 4 2
7 5 3 1
8 6 4 2
7 5 3 1
P5 P3
P6 P41 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
8 6 4 2
7 5 3 1
8 6 4 2
7 5 3 1
P5 P3
Relay Outputs mode selectors(see below box)
Mother board Connectors(Opposite side)
Mother board Connectors(Opposite side)
1N4004
Isolated Power Supply DC
OUT
AC IN
10 - 30V0V
123
CO
M
NO
/NC
Door lock
1N4004
Output on line 5/6relay selectors(Factory preset: No relay)
Line5: P23, P24 Line6: P21, P22
Output on line 7/8 relay selectors(Factory preset: No relay)
Line7: P17, P18Line8: P15, P16
TB7
P12
P10
P09
P11
TB8
8 6 4 2
7 5 3 1
8 6 4 2
7 5 3 1
P5 P3
VMA-06
Dry Contact Normally Open (Factory preset)
P4
1 3 5 7
2 4 6 8
P6
1 3 5 7
2 4 6 8
8 6 4 2
7 5 3 1P5
8 6 4 2
7 5 3 1
P3
Dry Contact Normally Closed
P4
1 3 5 7
2 4 6 8
P6
1 3 5 7
2 4 6 8
8 6 4 2
7 5 3 1
P5
8 6 4 2
7 5 3 1
P3
P4
1 3 5 7
2 4 6 8
P6
1 3 5 7
2 4 6 8
8 6 4 2
7 5 3 1P5
8 6 4 2
7 5 3 1
P3
P4
1 3 5 7
2 4 6 8
P6
1 3 5 7
2 4 6 8
8 6 4 2
7 5 3 1P5
8 6 4 2
7 5 3 1
P3
Power Output Normally Open
Power Output Normally Closed
VMA-06
Using Fixed Output 1Relay Normally open
J1
Relay Outputs mode selectors(See below box)
Mother board Connectors(Opposite side)
Mother board Connectors(Opposite side)
Input to cut of POE/POE+ power supply
8 6 4 2
7 5 3 1
8 6 4 2
7 5 3 1
P5 P3
P6 P41 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
1 2 3 1 2
P08
P07
P04
P05
TB09
TB10
J1
P6 P41 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
VMA-07
NO
/NC
CO
M Emergency IN(non polarized,Normally closed)
1 2When door lock is powered from the Voyager Multi device supplied from POE+ using the VMA-07 relay plug in it is possible to have an external signal used to drive the cut of the power at the door. This is used in case of emergency as, for example, in case of fire alarm.Please refer the opposit sheet side on how mount the VMA-07 plug in.
Using VMA-06 and VMA-07 plug ins it ispossible to directly power the door lock. This possibility is conditioned from:- The power source of Voyager Multi - The number and power absorbed from locks - The number and power absorbed from readers and other outputs Please refer the Installation manual for an extensive discussion of this topic and the Tema-Voyager Multi - Consumption Verifier Tool that helps in verifying the consumption.