1
UPPER LEVEL FLOOR PLAN SCALE: 1" = 30’-0" DLT REVISION DATE PROJECT NO. DRAWN BY: DATE: SHEET NO. OWNERSHIP OF DOCUMENTS Copyright C Drawings and Specifications as instruments of service Architect whether the Project for which they are made is executed or not. They are not to be used by encompass, inc. DENNIS LEE TAGGART, Architect are and shall remain the property of Dennis L. Taggart, appropriate compensation to Dennis L. Taggart, Architect the Owner on this or other projects or extensions to this project except by agreement in writing and with N.C.A.R.B., Certified: * A.S.I.D. Licensed Professional 2016 Dennis L. Taggart, Architect JG 16-1 DEC 20, 2016 436 WEST BROADWAY AVENUE, MERIDIAN, IDAHO 83642 OFFICE (208) 344-8800 e-mail [email protected] ARIZONA . CALIFORNIA . COLORADO . IDAHO . KANSAS MONTANA . NORTH CAROLINA . NEW MEXICO . TEXAS . UTAH AS-1 for STATE OF IDAHO AR-1262 LICENSED ARCHITECT DENNIS LEE TAGGART 1"=30’ Scale Architectural Site Plans "Parcel B" SELF- Jay Gibbons 12-20-16 .28^ .28^ 48.55^ .25^ 20’ 35’ 20’ 35’ 20’ 35’ 20’ 40’ 70’ 10’ 130’ 10’ 25’ 10’ 200’ 10’ 260’ 10’ 280’ 280’ 280’ 30’ 24’ 30’ 20’ 30’ 30’ 30’ 70’ 10’ 10’ 10’ 130’ 20’ 6’ 310’ 10’ 35’ 34’+/- 22’ 53’+/- 450’ 30’ 40’ 15’ 25’ 345’ 15’ Landscape Buffer Landscape Buffer 33’+/- 28’+/- 28’+/- 26’+/- Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8 Group 9 Group 10 Group 11 ROW ROW 10TH AVE. SOUTH LASTER ST. Fence To Match Bldg Security Gates See SHT A-1 For Detailed Information This Area NORTH S41^07’29"E 587.60’ PHYLLIS CANAL S89^45’18"W 338.56’ S00^17’01"W 442.66’ 641.29’ N89^44’50"E N89^44’49"E 84.42’ 5’ 35’ Laster and 10th Avenue South Caldwell, Idaho STORAGE FACILITY Cross-Hatched Areas Indicate Phase II ^ See Civil Engineer Drawings for Detailed Site Development Information ^ See Structural Engineering Drawings for Detailed Building Construction Information NOTE*** ^ Cross Hatched Areas are Phase II 3 Hr Fire Wall 140’ 130’ 150’ 3 Hr Fire Wall 3 Hr Fire Wall 150’ 3 Hr Fire Wall 140’ 3 Hr Fire Wall 150’ 160’ 3 Hr Fire Wall 3 Hr Fire Wall 190’ 140 3 Hr Fire Wall 3 Hr Fire Wall 10’ 20’-0" 200’ 210’ 20’ 5’+/- 3 Hr Fire Wall 3 Hr Fire Wall 3 Hr Fire Wall 14’+/- 10’-0" 2’-4"+/- 230’ 5’+/- 80’ 80’ 70’ 3 Hr Fire Wall 1. Revisions 2-10-17 1 1 1 1 3 Hr Fire Wall VAN 57’-8"+/- 4 20’ 26’ 10’ 5’-4" 39’-8"+/- 28’-8"+/- 10’ Knox Box Knox Box NOTES*** 1 Fire Access Roads Shall Be Marked With Permanent " NO PARKING" Signs in Compliance With IFC D103.6. Fire Access Roadways 20-26’ Wide Shall Be Marked on Both Sides. Fire access Roadway 26’-32’ Shall be Marked On One side Only. 2. Gates Shall Be A Minimum of 20’ in Width and Be Operable By One Person. Gates Shall Comply With UL 325 and ASTM 2200. Electric Gates Shall be Operable By, And Approved By, Fire Department Personnel 3. Provide (1) 2-A 10# BC Fire Extinguisher In Metal Exterior Grade Cabinet Within 150 LF Max Spacing (75 LF Travel Distance. Cabinets Shall Have Approved Theft Protective Covers Mount 3’-5’ Above Grade. Cabinets Shall Be Red in Color and Appropriately Labeled Bi-Directrional Signes shall Be Placed On Sides Or Above Each Fire Extinguisher Cabinet 1

UPPER LEVEL FLOOR PLAN AS-1...Group 4 Group 5 Group 6 Group 7 Group 8 Group 9 Group 10 Group 11 ROW ROW 10TH AVE. SOUTH LASTER ST. Fence To Match Bldg Security Gates See SHT A-1 For

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UPPER LEVEL FLOOR PLAN AS-1...Group 4 Group 5 Group 6 Group 7 Group 8 Group 9 Group 10 Group 11 ROW ROW 10TH AVE. SOUTH LASTER ST. Fence To Match Bldg Security Gates See SHT A-1 For

UPPER LEVEL FLOOR PLANSCALE: 1" = 30’-0"

DLT

REVISION DATE

PROJECT NO.

DRAWN BY:

DATE:

SHEET NO.

OWNERSHIP OF DOCUMENTS

Copyright C

Drawings and Specifications as instruments of service

Architect whether the Project for which they are

made is executed or not. They are not to be used by

en

co

mp

ass,

inc.

DE

NN

IS

L

EE

T

AG

GA

RT

, A

rch

itect

are and shall remain the property of Dennis L. Taggart,

appropriate compensation to Dennis L. Taggart, Architect

the Owner on this or other projects or extensions to

this project except by agreement in writing and with

N.C

.A.R

.B., C

erti

fie

d:

* A

.S.I

.D. L

icensed P

rofessio

nal

2016 Dennis L. Taggart, Architect

JG 16-1

DEC 20, 2016

43

6 W

ES

T B

RO

AD

WA

Y A

VE

NU

E,

ME

RID

IA

N,

ID

AH

O

83

64

2

OF

FIC

E (

20

8) 3

44

-8

80

0

e-m

ail

dennis

leeta

ggart@

gm

ail

.com

AR

IZ

ON

A . C

AL

IF

OR

NIA

. C

OL

OR

AD

O . I

DA

HO

. K

AN

SA

S

MO

NT

AN

A . N

OR

TH

CA

RO

LIN

A . N

EW

ME

XIC

O . T

EX

AS

. U

TA

H

AS-1

fo

r

STATE OF IDAHO

AR-1262

LICENSED

ARCHITECT

DENNIS LEE TAGGART

1"=30’ Scale

Architectural Site Plans

"Parcel B"

SE

LF

-

Jay G

ibbons

12-20-1

6

.28^

.28^

48.55^

.25^

30’-0"10’-0"

20’35’20’35’20’35’20’40’

70

’10’

130’

10’

25’10’

200’

10’

260’

10’

280’

280’

280’

30’ 24’ 30’ 20’ 30’ 30’

30’

70’10’ 10’ 10’

130’

20

’6

’310’

10

’35’

34’+

/-

22’

53’+

/-

450’

30’

40’

15

’2

5’

345’

15

LandscapeBuffer

LandscapeBuffer

33’+

/-

28’+

/-

28’+

/-

26’+

/-

Group 1

Gro

up

2

Group 3

Gro

up

4

Gro

up

5

Group 6

Gro

up

7

Gro

up

8

Group 9

Gro

up 1

0

Group 11

RO

W

ROW

10T

H A

VE

. S

OU

TH

LASTER ST.

Fence ToMatch Bldg

SecurityGates

See SHT A-1For DetailedInformationThis Area

NORTH

S41^07’2

9"E

587.6

0’

PH

YLLIS

CA

NA

L

S89^45’18"W

338.56’

S00^17’0

1"W

442.6

6’

641.29’

N89^44’50"EN89^44’49"E

84.42’

5’

35’

Laster and 10th A

venue S

outh

Caldw

ell, Idaho

ST

OR

AG

E F

AC

IL

IT

Y

Cross-Hatched AreasIndicate Phase II

^ See Civil Engineer Drawings for Detailed Site Development Information^ See Structural Engineering Drawings for Detailed Building Construction Information

NOTE***

^ Cross Hatched Areas are Phase II

3 HrFire Wall

140’

130’

150’

3 HrFire Wall

3 HrFire Wall

150’

3 HrFire Wall

140’

3 HrFire Wall

150’

160’

3 HrFire Wall

3 HrFire Wall

190’140

3 HrFire Wall

3 HrFire Wall

10’

20’-0

"

200’

210’

20’

5’+

/-

3 HrFire Wall

3 HrFire Wall

3 HrFire Wall

14’+

/-

10’-0"2’-4"+/-

230’5’+/-

80’ 80’ 70’

3 HrFire Wall

1. Revisions 2-10-17

1

1

1

13 HrFire Wall

VA

N

57’-8"+/-

4

20’

26’

10’

5’-4"

39’-8"+

/-

28

’-8

"+

/-

10’KnoxBox

KnoxBox

NOTES***

1 Fire Access Roads Shall Be Marked With

Permanent " NO PARKING" Signs in Compliance

With IFC D103.6. Fire Access Roadways

20-26’ Wide Shall Be Marked on Both Sides.

Fire access Roadway 26’-32’ Shall be Marked

On One side Only.

2. Gates Shall Be A Minimum of 20’ in Width and

Be Operable By One Person. Gates Shall

Comply With UL 325 and ASTM 2200. Electric

Gates Shall be Operable By, And Approved By,

Fire Department Personnel

3. Provide (1) 2-A 10# BC Fire Extinguisher

In Metal Exterior Grade Cabinet Within

150 LF Max Spacing (75 LF Travel Distance.

Cabinets Shall Have Approved Theft

Protective Covers

Mount 3’-5’ Above Grade. Cabinets Shall Be

Red in Color and Appropriately Labeled

Bi-Directrional Signes shall Be Placed On

Sides Or Above Each Fire Extinguisher Cabinet

1