5
Universal Gland Flameproof System Size Ref (Condui t Size) Part No. Gland Body Gland Nut Metric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overal l Length A/F A/C A/F A/C Thread 16 – 3/8” HAM*0304U 28.6 31.0 32.0 34.0 M16 M20 10.5 10.0 9 56.0 HAA*0304U 3/8” ½” 60.0 20 – ½” HAM*0404U 28.6 31.0 32.0 34.0 M20 M20 13.0 13.0 15 56.0 HAA*0404U ½” ½” 60.0 25 – ¾” HAM*0505U 34.0 37.0 34.0 34.9 SS 37.0 M25 M25 17.9 17.9 28 56.0 HAA*0505U 3/4” ¾” 65.4 32 – 1” HAM*0606U 42.0 45.0 42.0 42.5 SS 45.0 M32 M32 24.0 20.0 50 56.0 HAA*0606U 1” 1” 65.4 40 – 1 ¼” HAM*0707U 50.0 54.0 52.0 57.0 M40 M40 32.0 32.0 75 60.0 HAA*0707U 1 ¼” 1 ¼” 71.0 50 – 1 ½” HAM*0808U 60.0 64.0 60.0 64.0 M50 M50 35.0 35.0 80 63.0 HAA*0808U 1 ½” 1 ½” 71.0 63 – 2” HAM*0909U 70.0 76.0 70.0 69.8 SS 76.0 M63 M63 45.0 45.0 100 74.0 HAA*0909U 2” 2” 81.0 Description - Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use - Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits - Suitable for all conduits including: Rigid - Metallic - Non Metallic Approvals - ATEX directive 94/9/EC (ATEX 95) to standards IEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079- 31:2008 Ed 1 EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008 Certifications - ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA09.0103X 2310045 ny’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Embed Size (px)

Citation preview

Page 1: Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Universal GlandFlameproof System

Size Ref(Conduit

Size)

Part No. Gland Body Gland Nut Metric/NPT

Max Dia.Over Cores

Max Dia.Over Single

Core

Max No.Of Cores

OverallLength

A/F A/C A/F A/C Thread

16 – 3/8”HAM*0304U

28.6 31.0 32.0 34.0M16 M20

10.5 10.0 956.0

HAA*0304U 3/8” ½” 60.0

20 – ½”HAM*0404U

28.6 31.0 32.0 34.0M20 M20

13.0 13.0 1556.0

HAA*0404U ½” ½” 60.0

25 – ¾”HAM*0505U

34.0 37.034.0

34.9 SS37.0

M25 M2517.9 17.9 28

56.0

HAA*0505U 3/4” ¾” 65.4

32 – 1”HAM*0606U

42.0 45.042.0

42.5 SS45.0

M32 M3224.0 20.0 50

56.0

HAA*0606U 1” 1” 65.4

40 – 1 ¼”HAM*0707U

50.0 54.0 52.0 57.0M40 M40

32.0 32.0 7560.0

HAA*0707U 1 ¼” 1 ¼” 71.0

50 – 1 ½”HAM*0808U

60.0 64.0 60.0 64.0M50 M50

35.0 35.0 8063.0

HAA*0808U 1 ½” 1 ½” 71.0

63 – 2”HAM*0909U

70.0 76.070.0

69.8 SS76.0

M63 M6345.0 45.0 100

74.0

HAA*0909U 2” 2” 81.0

Description - Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry

IP66, -60°C to +130°C

Exd I&IIC Exe I&II Extb IIIC

Intended Use - Groups I and II

Zones 1, 2, 21 and 22

Class I Div I BCD (Rigid Conduit Only)

Class II Div I EFG

Exde I Mb

Exde IIC Gb

Extb IIIC Db

Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316

HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel

Compatible Conduits - Suitable for all conduits including:

Rigid - Metallic - Non Metallic

Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1

EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008

Certifications - ATEX IECEx CSA

SIRA09ATEX1231X IECEx SIRA09.0103X 2310045

The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.

NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.

9/5/12

Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Page 2: Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Universal GlandFlameproof System

Size Ref(Conduit

Size)

Part No. Gland Body 90° Elbow Metric/NPT

Max Dia.Over Cores

Max Dia.Over Single

Core

Max No.Of Cores

OverallLength

A/F A/C A/F Conduit

16 – 3/8”HAM*0304E

28.6 31.0 32.0 16mmM20

10.5 10.0 9 90.0HAA*0304E ½”

20 – ½”HAM*0404E

28.6 31.0 32.0 20mmM20

13.0 13.0 15 90.0HAA*0404E ½”

25 – ¾”HAM*0505E

34.0 37.034.0

34.9 SS25mm

M2517.9 17.9 28 104.0

HAA*0505E ¾”

32 – 1”HAM*0606E

42.0 45.042.0

42.5 SS32mm

M3224.0 20.0 50 114.0

HAA*0606E 1”

40 – 1 ¼”HAM*0707E

50.0 54.0 52.0 40mmM40

32.0 32.0 75 180.0HAA*0707E 1 ¼”

50 – 1 ½”HAM*0808E

60.0 64.0 60.0 50mmM50

35.0 35.0 80 146.0HAA*0808E 1 ½”

63 – 2”HAM*0909E

70.0 76.070.0

69.8 SS63mm

M6345.0 45.0 100 169.0

HAA*0909E 2”

Description -Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits

IP66

-60°C to +130°C

Exd I&IIC Exe I&II Extb IIIC

Intended Use - Groups I and IIZones 1, 2, 21 and 22

Class I Div I BCD (Rigid Conduit Only)

Class II Div I EFG

Exde I Mb

Exde IIC Gb

Extd IIIC Db

Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316

HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel

Compatible Conduits - EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC

Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1

EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008

Certifications - ATEX IECEx CSA

SIRA09ATEX1231X IECEx SIRA09.0103X 2310045

The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.

NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.

9/5/12

Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Page 3: Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Universal GlandFlameproof System

Size Ref(Conduit

Size)

Part No. Gland Body Gland Nut Metric/NPT

Max Dia.Over Cores

Max Dia.Over Single

Core

Max No.Of Cores

OverallLength

A/F A/C A/F A/C

16 – 3/8”HAM*0304G1

28.6 31.0 32.0 34.0M20

10.5 10.0 9 50.0HAA*0304G1 ½”

20 – ½”HAM*0404G1

28.6 31.0 32.0 34.0M20

13.0 13.0 15 50.0HAA*0404G1 ½”

25 – ¾”HAM*0505G1

34.0 37.034.0

34.9 SS37.0

M2517.9 17.9 28 50.0

HAA*0505G1 ¾”

32 – 1”HAM*0606G1

42.0 45.042.0

42.5 SS45.0

M3224.0 20.0 50 50.0

HAA*0606G1 1”

40 – 1 ¼”HAM*0707G1

50.0 54.0 52.0 57.0M40

32.0 32.0 75 57.0HAA*0707G1 1 ¼”

50 – 1 ½”HAM*0808G1

60.0 64.0 60.0 64.0M50

35.0 35.0 80 58.0HAA*0808G1 1 ½”

63 – 2”HAM*0909G1

70.0 76.070.0

69.8 SS76.0

M6345.0 45.0 100 70.0

HAA*0909G1 2”

Description - Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits

IP66, -60°C to +130°C

Exd I&IIC Exe I&II Extb IIIC

Intended Use - Group I and II

Zones 1, 2, 21 & 22

Class I Div II ABCD

Class II Div I EFG

Exde I Mb

Exde IIC Gb

Extb IIIC Db

Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316

HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel

Compatible Conduits - EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC

Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1

EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008

Certifications - ATEX IECEx CSA

SIRA09ATEX1231X IECEx SIRA09.0103X 2310045

The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.

NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.

9/5/12

Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

Page 4: Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Universal GlandFlameproof System

PART No. BODY A/F ‘A’

THREAD ‘B’

MIN BORE ‘C’

‘D’ ‘E’ NUT A/F ‘F’

EXPQM0303 25.4 M16 11.4 16.0 33.25 25.4

EXPQM0404 28.0 M20 15.8 16.0 32.0 28.0

EXPQM0505 38.0 M25 19.0 16.0 39.0 38.0

EXPQM0606 42.0 M32 26.4 17.0 40.0 44.5

EXPQM0707 54.0 M40 32.9 17.0 49.5 57.0

EXPQM0808 70.0 M50 43.9 16.0 48.0 70.0

EXPQA0304 24.0 ½” NPT 11.4 20.0 32.5 25.4

EXPQA0404 28.0 ½” NPT 15.8 20.0 31.5 28.0

EXPQA0505 38.0 ¾” NPT 19.0 20.2 38.3 38.0

EXPQA0606 42.0 1” NPT 26.4 24.2 40.0 44.5

EXPQA0707 54.0 1 ¼” NPT 32.9 25.8 49.5 57.0

EXPQA0808 70.0 1 ½” NPT 40.7 26.1 48.0 70.0

Description - For use with standard weight braided antistatic conduit EXB,

Material - Body and Nut : Nickel plated Brass

Seals: Silicone

Intended Use - An electrically discharging cable protection system.

This system protects electrical cables and wires from mechanical damage and UV radiation

Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC

Compatible Conduits - EXB Antistatic Polyamide 12 Conduit

Approvals - ATEX directive 94/9/EC (ATEX 95) to standards

IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1.

Certifications - ATEX IECEx

BASEEFA ATEX08.0003X IECEx BAS08.0001X

The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.

NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.

9/5/12

Page 5: Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No

Universal GlandFlameproof System

PART No. BODY A/F ‘A’

THREAD ‘B’

MIN BORE ‘C’

‘D’ ‘E’ NUT A/F ‘F’

EXBQM0303 24.0 M16 11.4 18.0 43.5 30.0

EXBQM0404 28.0 M20 15.8 16.0 43.5 35.0

EXBQM0505 38.0 M25 19.0 16.0 50.0 44.5

EXBQM0606 42.0 M32 26.4 18.0 51.0 50.0

EXBQM0707 54.0 M40 32.9 18.0 67.5 70.0

EXBQM0808 70.0 M50 43.9 16.0 70.0 84.0

EXBQA0304 24.0 ½” NPT 11.4 20.0 44.5 30.0

EXBQA0404 28.0 ½” NPT 15.8 20.0 45.0 35.0

EXBQA0505 38.0 ¾” NPT 19.0 20.2 54.0 44.5

EXBQA0606 42.0 1” NPT 26.4 24.2 57.5 50.0

EXBQA0707 54.0 1 ¼” NPT 32.9 25.8 70.0 70.0

EXBQA0808 70.0 1 ½” NPT 40.7 26.1 70.0 84.0

Description - For use with standard weight braided antistatic conduit EXBB, this system gives additional wear and EMC Protection

Material - Body, Nut and Internal components: Nickel plated Brass

Seals: Silicone

Intended Use - An electrically discharging cable protection system.

This system protects electrical cables and wires from mechanical damage and UV radiation

Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC

Compatible Conduits - EXBB Stainless Steel Overbraided Antistatic Polyamide 12 Conduit

Approvals - ATEX directive 94/9/EC (ATEX 95) to standards

IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1.

Certifications - ATEX IECEx

BASEEFA ATEX08.0003X IECEx BAS08.0001X

The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.

NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.

9/5/12