Upload
georgina-mcdaniel
View
216
Download
0
Embed Size (px)
Citation preview
Universal GlandFlameproof System
Size Ref(Conduit
Size)
Part No. Gland Body Gland Nut Metric/NPT
Max Dia.Over Cores
Max Dia.Over Single
Core
Max No.Of Cores
OverallLength
A/F A/C A/F A/C Thread
16 – 3/8”HAM*0304U
28.6 31.0 32.0 34.0M16 M20
10.5 10.0 956.0
HAA*0304U 3/8” ½” 60.0
20 – ½”HAM*0404U
28.6 31.0 32.0 34.0M20 M20
13.0 13.0 1556.0
HAA*0404U ½” ½” 60.0
25 – ¾”HAM*0505U
34.0 37.034.0
34.9 SS37.0
M25 M2517.9 17.9 28
56.0
HAA*0505U 3/4” ¾” 65.4
32 – 1”HAM*0606U
42.0 45.042.0
42.5 SS45.0
M32 M3224.0 20.0 50
56.0
HAA*0606U 1” 1” 65.4
40 – 1 ¼”HAM*0707U
50.0 54.0 52.0 57.0M40 M40
32.0 32.0 7560.0
HAA*0707U 1 ¼” 1 ¼” 71.0
50 – 1 ½”HAM*0808U
60.0 64.0 60.0 64.0M50 M50
35.0 35.0 8063.0
HAA*0808U 1 ½” 1 ½” 71.0
63 – 2”HAM*0909U
70.0 76.070.0
69.8 SS76.0
M63 M6345.0 45.0 100
74.0
HAA*0909U 2” 2” 81.0
Description - Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry
IP66, -60°C to +130°C
Exd I&IIC Exe I&II Extb IIIC
Intended Use - Groups I and II
Zones 1, 2, 21 and 22
Class I Div I BCD (Rigid Conduit Only)
Class II Div I EFG
Exde I Mb
Exde IIC Gb
Extb IIIC Db
Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316
HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel
Compatible Conduits - Suitable for all conduits including:
Rigid - Metallic - Non Metallic
Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1
EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008
Certifications - ATEX IECEx CSA
SIRA09ATEX1231X IECEx SIRA09.0103X 2310045
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.
9/5/12
Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75
Universal GlandFlameproof System
Size Ref(Conduit
Size)
Part No. Gland Body 90° Elbow Metric/NPT
Max Dia.Over Cores
Max Dia.Over Single
Core
Max No.Of Cores
OverallLength
A/F A/C A/F Conduit
16 – 3/8”HAM*0304E
28.6 31.0 32.0 16mmM20
10.5 10.0 9 90.0HAA*0304E ½”
20 – ½”HAM*0404E
28.6 31.0 32.0 20mmM20
13.0 13.0 15 90.0HAA*0404E ½”
25 – ¾”HAM*0505E
34.0 37.034.0
34.9 SS25mm
M2517.9 17.9 28 104.0
HAA*0505E ¾”
32 – 1”HAM*0606E
42.0 45.042.0
42.5 SS32mm
M3224.0 20.0 50 114.0
HAA*0606E 1”
40 – 1 ¼”HAM*0707E
50.0 54.0 52.0 40mmM40
32.0 32.0 75 180.0HAA*0707E 1 ¼”
50 – 1 ½”HAM*0808E
60.0 64.0 60.0 50mmM50
35.0 35.0 80 146.0HAA*0808E 1 ½”
63 – 2”HAM*0909E
70.0 76.070.0
69.8 SS63mm
M6345.0 45.0 100 169.0
HAA*0909E 2”
Description -Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits
IP66
-60°C to +130°C
Exd I&IIC Exe I&II Extb IIIC
Intended Use - Groups I and IIZones 1, 2, 21 and 22
Class I Div I BCD (Rigid Conduit Only)
Class II Div I EFG
Exde I Mb
Exde IIC Gb
Extd IIIC Db
Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316
HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel
Compatible Conduits - EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC
Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1
EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008
Certifications - ATEX IECEx CSA
SIRA09ATEX1231X IECEx SIRA09.0103X 2310045
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.
9/5/12
Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75
Universal GlandFlameproof System
Size Ref(Conduit
Size)
Part No. Gland Body Gland Nut Metric/NPT
Max Dia.Over Cores
Max Dia.Over Single
Core
Max No.Of Cores
OverallLength
A/F A/C A/F A/C
16 – 3/8”HAM*0304G1
28.6 31.0 32.0 34.0M20
10.5 10.0 9 50.0HAA*0304G1 ½”
20 – ½”HAM*0404G1
28.6 31.0 32.0 34.0M20
13.0 13.0 15 50.0HAA*0404G1 ½”
25 – ¾”HAM*0505G1
34.0 37.034.0
34.9 SS37.0
M2517.9 17.9 28 50.0
HAA*0505G1 ¾”
32 – 1”HAM*0606G1
42.0 45.042.0
42.5 SS45.0
M3224.0 20.0 50 50.0
HAA*0606G1 1”
40 – 1 ¼”HAM*0707G1
50.0 54.0 52.0 57.0M40
32.0 32.0 75 57.0HAA*0707G1 1 ¼”
50 – 1 ½”HAM*0808G1
60.0 64.0 60.0 64.0M50
35.0 35.0 80 58.0HAA*0808G1 1 ½”
63 – 2”HAM*0909G1
70.0 76.070.0
69.8 SS76.0
M6345.0 45.0 100 70.0
HAA*0909G1 2”
Description - Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits
IP66, -60°C to +130°C
Exd I&IIC Exe I&II Extb IIIC
Intended Use - Group I and II
Zones 1, 2, 21 & 22
Class I Div II ABCD
Class II Div I EFG
Exde I Mb
Exde IIC Gb
Extb IIIC Db
Material - Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316
HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel
Compatible Conduits - EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC
Approvals - ATEX directive 94/9/EC (ATEX 95) to standardsIEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1
EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008
Certifications - ATEX IECEx CSA
SIRA09ATEX1231X IECEx SIRA09.0103X 2310045
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.
9/5/12
Gland comes complete with two part epoxy putty, gloves and fitting instructions.Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75
Universal GlandFlameproof System
PART No. BODY A/F ‘A’
THREAD ‘B’
MIN BORE ‘C’
‘D’ ‘E’ NUT A/F ‘F’
EXPQM0303 25.4 M16 11.4 16.0 33.25 25.4
EXPQM0404 28.0 M20 15.8 16.0 32.0 28.0
EXPQM0505 38.0 M25 19.0 16.0 39.0 38.0
EXPQM0606 42.0 M32 26.4 17.0 40.0 44.5
EXPQM0707 54.0 M40 32.9 17.0 49.5 57.0
EXPQM0808 70.0 M50 43.9 16.0 48.0 70.0
EXPQA0304 24.0 ½” NPT 11.4 20.0 32.5 25.4
EXPQA0404 28.0 ½” NPT 15.8 20.0 31.5 28.0
EXPQA0505 38.0 ¾” NPT 19.0 20.2 38.3 38.0
EXPQA0606 42.0 1” NPT 26.4 24.2 40.0 44.5
EXPQA0707 54.0 1 ¼” NPT 32.9 25.8 49.5 57.0
EXPQA0808 70.0 1 ½” NPT 40.7 26.1 48.0 70.0
Description - For use with standard weight braided antistatic conduit EXB,
Material - Body and Nut : Nickel plated Brass
Seals: Silicone
Intended Use - An electrically discharging cable protection system.
This system protects electrical cables and wires from mechanical damage and UV radiation
Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC
Compatible Conduits - EXB Antistatic Polyamide 12 Conduit
Approvals - ATEX directive 94/9/EC (ATEX 95) to standards
IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1.
Certifications - ATEX IECEx
BASEEFA ATEX08.0003X IECEx BAS08.0001X
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.
9/5/12
Universal GlandFlameproof System
PART No. BODY A/F ‘A’
THREAD ‘B’
MIN BORE ‘C’
‘D’ ‘E’ NUT A/F ‘F’
EXBQM0303 24.0 M16 11.4 18.0 43.5 30.0
EXBQM0404 28.0 M20 15.8 16.0 43.5 35.0
EXBQM0505 38.0 M25 19.0 16.0 50.0 44.5
EXBQM0606 42.0 M32 26.4 18.0 51.0 50.0
EXBQM0707 54.0 M40 32.9 18.0 67.5 70.0
EXBQM0808 70.0 M50 43.9 16.0 70.0 84.0
EXBQA0304 24.0 ½” NPT 11.4 20.0 44.5 30.0
EXBQA0404 28.0 ½” NPT 15.8 20.0 45.0 35.0
EXBQA0505 38.0 ¾” NPT 19.0 20.2 54.0 44.5
EXBQA0606 42.0 1” NPT 26.4 24.2 57.5 50.0
EXBQA0707 54.0 1 ¼” NPT 32.9 25.8 70.0 70.0
EXBQA0808 70.0 1 ½” NPT 40.7 26.1 70.0 84.0
Description - For use with standard weight braided antistatic conduit EXBB, this system gives additional wear and EMC Protection
Material - Body, Nut and Internal components: Nickel plated Brass
Seals: Silicone
Intended Use - An electrically discharging cable protection system.
This system protects electrical cables and wires from mechanical damage and UV radiation
Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC
Compatible Conduits - EXBB Stainless Steel Overbraided Antistatic Polyamide 12 Conduit
Approvals - ATEX directive 94/9/EC (ATEX 95) to standards
IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1.
Certifications - ATEX IECEx
BASEEFA ATEX08.0003X IECEx BAS08.0001X
The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice.
NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED.
9/5/12