2
ON THE WELLHEAD 5 Simple Installation and Removal . 5 Adds 6.5” to Wellhead height. 5 Can adapt to any A.P.A.Wellhead in its range. 5 No Wellhead Modification Required. 5 No custom built Tubing Hangers required. 5 Utilizes existing Wellhead Components. 5 Can be converted to 3 1/2, 2 7/8 or 2 3/8 EUE by simply changing the Mandrel. 5 Lower Ring Gasket can be pressure tested. 5 Virtually maintenance free. 5 Can be adapted for thermal applications up to 210 C. 5 Components are built to API specifications. DOWNHOLE WELL ASSEMBLY 5 Prolongs Tubing Life 6-10 times. 5 Paraffin build-up eliminated. (in most cases) 5 Rod hang-up eliminated. (in most cases) 5 Abnormal pump wear eliminated. 5 Sand build-up in pump barrel eliminated. 5 Enhances corrosion inhibitors. Model JDHS Jay Latch Swivel Model CRTA Rotating Tubing Anchor Catcher Run with Conventional Anchors & Packers Run on Beam Pump Wells The CRTA Rotating Anchor Catcher allows the entire tub- ing string including the tailpipe and pump seating nipple to rotate while pulled into ten- sion. This system is excellent on directional or horizontal wells where the anchor is to be set in the vertical section. The JDHS Jaylatch Down Hole Swivel is designed to be run in conjunction with the IPS Tubing Rotator on pumping wells that have a con- ventional anchor or packer in them. Model CDHS Downhole Swivel Run with Anti-Rotation Anchor The CDHS Clutched Downhole Swivel Assembly is designed to be run in conjunc- tion with the IPS Tubing Rotator on pumping wells that utilize a progressive cavity pump and an anti- rotation anchor. IPS WILL CUSTOM DESIGN AND BUILD IPS WILL CUSTOM DESIGN AND BUILD TUBING ROTATORS TO MEET YOUR NEEDS ! TUBING ROTATORS TO MEET YOUR NEEDS ! COMPOSITE PUMPING TREE CONVENTIONAL WELLHEAD 5 Composite Pumping tree is third party supplied 5 Requires non-studded rotator 5 Conventional Wellhead is third party supplied 5 Requires studded rotator CONVENTIONAL TUBING HANGER NO TUBING HANGER MODIFIED TUBING HANGER

Tubing Rotator

Embed Size (px)

DESCRIPTION

Archivo técnico

Citation preview

  • ON THE WELLHEAD

    5 Simple Installation and Removal .5 Adds 6.5 to Wellhead height.5 Can adapt to any A.P.A. Wellhead in its

    range.5 No Wellhead Modification Required.5 No custom built Tubing Hangers

    required.5 Utilizes existing Wellhead Components.

    5 Can be converted to 3 1/2, 2 7/8 or 2 3/8 EUE by simply changing the Mandrel.

    5 Lower Ring Gasket can be pressure tested.

    5 Virtually maintenance free.5 Can be adapted for thermal applications

    up to 210 C.5 Components are built to API specifications.

    DOWNHOLEWELL ASSEMBLY

    5 Prolongs Tubing Life 6-10 times.5 Paraffin build-up eliminated. (in most cases)5 Rod hang-up eliminated. (in most cases)5 Abnormal pump wear eliminated.5 Sand build-up in pump barrel

    eliminated.5 Enhances corrosion inhibitors.

    Model JDHS Jay Latch Swivel

    Model CRTARotating TubingAnchor Catcher

    Run with ConventionalAnchors & Packers

    Run on Beam PumpWells

    The CRTARotatingAnchorCatcher allowsthe entire tub-ing stringincluding thetailpipe andpump seatingnipple torotate whilepulled into ten-sion. Thissystem isexcellent ondirectional orhorizontalwells wherethe anchor isto be set inthe verticalsection.

    The JDHSJaylatch DownHole Swivel isdesigned to berun in conjunctionwith the IPSTubing Rotator onpumping wellsthat have a con-ventional anchoror packer inthem.

    Model CDHSDownhole Swivel

    Run with Anti-RotationAnchor

    The CDHSClutchedDownholeSwivelAssembly isdesigned to berun in conjunc-tion with theIPS TubingRotator onpumping wellsthat utilize aprogressivecavity pumpand an anti-rotation anchor.

    IPS WILL CUSTOM DESIGN AND BUILDIPS WILL CUSTOM DESIGN AND BUILDTUBING ROTATORS TO MEET YOUR NEEDS !TUBING ROTATORS TO MEET YOUR NEEDS !

    COMPOSITE PUMPING TREE CONVENTIONAL WELLHEAD

    5 Composite Pumping tree is third party supplied

    5 Requires non-studded rotator

    5 Conventional Wellhead is third party supplied

    5 Requires studded rotator

    CONVENTIONALTUBING HANGER

    NO TUBINGHANGER

    MODIFIED TUBINGHANGER

  • 4). Screw Handling Sub into Mandrel

    5). Pick up on Handling Sub and Unseat hanger

    6). Install Catch Dogs and Optional Retaining Ring (FIGURE 2)

    7). Lower Mandrel/Hanger Assembly so Catch Dogs take the weight

    8). At this point tubing can be rotated and the Tubing Hanger is unseated

    AAR

    TIFF

    ICIAA

    L L

    IFFT

    SY

    ST

    EM

    S

    CTR

    #1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.caINTEGRATED PRODUCTION SERVICES

    ON THE SURFACE

    1). Screw Mandrel into the Tubing Hanger

    2). Insert Mandrel/Hanger Assembly into the Wellhead

    3). Lower Rotator onto Wellhead (FIGURE 1)

    NOTE: R ring gasket must be in place. IfHanger sits flush with wellhead as shown, useRX ring gasket.

    If Hanger is recessed, use standard R ringgasket.

    AAR

    TIFF

    ICIAA

    L L

    IFFT

    SY

    ST

    EM

    SROTATOR

    #1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca

    INTEGRATED PRODUCTION SERVICES

    MECHANICAL DRIVE

    IPS WILL LOWER YOUR PRODUCTION COSTSIPS WILL LOWER YOUR PRODUCTION COSTSContact your IPS Representative for more information

    MANUAL DRIVE

    5 Used onall types ofinstallations

    5 Utilizes the Pump Jack5 No external power source required

    ELECTRIC DRIVE

    5 Used with Pump Jacks and P.C.P Pumps5 Three Phase, Single Phase, or 12 Volt

    (Hydraulic Drive is also available)

    NOTE:Safety Shear Couplings areincorporated into each drivesystem, eliminating the possibil-ity of over-torquing the tubing.

    TUBING ROTATOR INSTALLATION