ON THE WELLHEAD
5 Simple Installation and Removal .5 Adds 6.5 to Wellhead height.5 Can adapt to any A.P.A. Wellhead in its
range.5 No Wellhead Modification Required.5 No custom built Tubing Hangers
required.5 Utilizes existing Wellhead Components.
5 Can be converted to 3 1/2, 2 7/8 or 2 3/8 EUE by simply changing the Mandrel.
5 Lower Ring Gasket can be pressure tested.
5 Virtually maintenance free.5 Can be adapted for thermal applications
up to 210 C.5 Components are built to API specifications.
DOWNHOLEWELL ASSEMBLY
5 Prolongs Tubing Life 6-10 times.5 Paraffin build-up eliminated. (in most cases)5 Rod hang-up eliminated. (in most cases)5 Abnormal pump wear eliminated.5 Sand build-up in pump barrel
eliminated.5 Enhances corrosion inhibitors.
Model JDHS Jay Latch Swivel
Model CRTARotating TubingAnchor Catcher
Run with ConventionalAnchors & Packers
Run on Beam PumpWells
The CRTARotatingAnchorCatcher allowsthe entire tub-ing stringincluding thetailpipe andpump seatingnipple torotate whilepulled into ten-sion. Thissystem isexcellent ondirectional orhorizontalwells wherethe anchor isto be set inthe verticalsection.
The JDHSJaylatch DownHole Swivel isdesigned to berun in conjunctionwith the IPSTubing Rotator onpumping wellsthat have a con-ventional anchoror packer inthem.
Model CDHSDownhole Swivel
Run with Anti-RotationAnchor
The CDHSClutchedDownholeSwivelAssembly isdesigned to berun in conjunc-tion with theIPS TubingRotator onpumping wellsthat utilize aprogressivecavity pumpand an anti-rotation anchor.
IPS WILL CUSTOM DESIGN AND BUILDIPS WILL CUSTOM DESIGN AND BUILDTUBING ROTATORS TO MEET YOUR NEEDS !TUBING ROTATORS TO MEET YOUR NEEDS !
COMPOSITE PUMPING TREE CONVENTIONAL WELLHEAD
5 Composite Pumping tree is third party supplied
5 Requires non-studded rotator
5 Conventional Wellhead is third party supplied
5 Requires studded rotator
CONVENTIONALTUBING HANGER
NO TUBINGHANGER
MODIFIED TUBINGHANGER
4). Screw Handling Sub into Mandrel
5). Pick up on Handling Sub and Unseat hanger
6). Install Catch Dogs and Optional Retaining Ring (FIGURE 2)
7). Lower Mandrel/Hanger Assembly so Catch Dogs take the weight
8). At this point tubing can be rotated and the Tubing Hanger is unseated
AAR
TIFF
ICIAA
L L
IFFT
SY
ST
EM
S
CTR
#1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.caINTEGRATED PRODUCTION SERVICES
ON THE SURFACE
1). Screw Mandrel into the Tubing Hanger
2). Insert Mandrel/Hanger Assembly into the Wellhead
3). Lower Rotator onto Wellhead (FIGURE 1)
NOTE: R ring gasket must be in place. IfHanger sits flush with wellhead as shown, useRX ring gasket.
If Hanger is recessed, use standard R ringgasket.
AAR
TIFF
ICIAA
L L
IFFT
SY
ST
EM
SROTATOR
#1000, 840 - 7th Avenue SW Calgary, AB, Canada T2P 3G2 [Tel] 403.266.0908 [Fax] 403.266.1639 [Web] www.ipsl.ca
INTEGRATED PRODUCTION SERVICES
MECHANICAL DRIVE
IPS WILL LOWER YOUR PRODUCTION COSTSIPS WILL LOWER YOUR PRODUCTION COSTSContact your IPS Representative for more information
MANUAL DRIVE
5 Used onall types ofinstallations
5 Utilizes the Pump Jack5 No external power source required
ELECTRIC DRIVE
5 Used with Pump Jacks and P.C.P Pumps5 Three Phase, Single Phase, or 12 Volt
(Hydraulic Drive is also available)
NOTE:Safety Shear Couplings areincorporated into each drivesystem, eliminating the possibil-ity of over-torquing the tubing.
TUBING ROTATOR INSTALLATION