Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp Stops Pages 1 - 18 Tubing and fitting problems Pages 19 - 21 Repair Clamp and FAST Pages 22 - 33 Coupling End Ring Pages 34 - 38 NOTE: Do not take apart and inspect - return items to the Ford Quality Assurance Staff in the exact condition that it is received from the field.

Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Embed Size (px)

Citation preview

Page 1: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Trouble ShootingHow to Recognize Improper Installations

January 2013

The Ford Meter Box Company, Inc.

Table of Contents

Valves and Corp Stops Pages 1 - 18

Tubing and fitting problemsPages 19 - 21

Repair Clamp and FAST Pages 22 - 33

Coupling End Ring Pages 34 - 38

NOTE: Do not take apart and inspect - return items to the Ford Quality Assurance Staff in the exact condition that it is received from the field.

Page 2: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Leaking valve. Pipe wrench distortions shown on a key style corp stop.

Page 3: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

1. Iron teeth easily distort brass material

2. Increased torque on wrench handle squeezes jaws more tightly against the valve or fitting.

3. Typical pipe wrench jaws are 5 to 7 degrees from parallel

Why pipe wrenches should not be used.

Page 4: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

A dye test shows that pipe wrench distortions

transferred through body. View 2 of 2

Raised Area

Page 5: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Proper Tools

Page 6: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

A loose-fitting, smooth-jawed wrench can distort valve body.

Page 7: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Wrench placement or looseness that caused valve body distortion.

Page 8: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Dye test shows loose wrench distortions transferred through valve body.

Page 9: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve leaks at valve body. Pipe wrench distortions break the machined seal between the valve body and the outlet assembly.

Outlet assembly

Valve body

Teeth marks from pipe wrench

Should locate smooth jaw

wrench on the flat area here

Page 10: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve leaks after backfill. A dye test shows a key style corp stop with an arched body.

No dye = lack of seal because of

no key contact

Incorrect!Vertical key

placement can distort or “arch” the valve when

backfilled

Correct!Valve installed on

its side will absorb higher backfill force

Page 11: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve leaks during pressure test. The grooves (scars) on the key are caused by operating the valve against stones or shavings. This valve was not properly flushed after installation.

Page 12: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

The key port is distorted from a drilling operation that was done with the key not completely open.

Page 13: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

The machined surface of a key corp body is scored from turning a distorted key.

Page 14: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve is hard to operate. Ball distortion results from freezing.

Page 15: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve leaks / Hard to operate. The key is bulged from the expansion of frozen water. The key was in the closed position when frozen. View 1 of 2

Page 16: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve leaks / hard to operate. The key is bulged from the expansion of frozen water. The key was in the closed position when frozen. View 2 of 2

Page 17: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve appears to be closed but allows water flow. A ball valve not fully closed when the tee-head is in a fully closed position. View 1 of 3

Page 18: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve appears to be closed but allows water flow. Note the twisted tee-head spade due to valve operation while frozen. View 2 of 3

Page 19: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Valve appears to be closed but allows water flow. The distortion of the ball slot is the result of operating the valve while frozen. View 3 of 3

Page 20: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Leaking compression fitting. Out-of-round copper tubing can cause a poor gasket seal.

Copper Rounding Tool

Page 21: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Leaks after in service for weeks or months. Deflected copper can cause a poor gasket seal.

The narrowing of the shiny band shows an uneven gasket seal. The leak usually occurs at the most narrow part of the shiny area.

Page 22: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

An incomplete insertion of the copper tube into the fitting allows too much deflection.

Page 23: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

TAPPING MACHINE/REPAIR CLAMPINSTALLATION

A torque wrench is highly recommended and required to ensure proper torque.

Page 24: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Equal torque must be applied to all bolts/nuts to prevent leak. The wavy side bar shows over-torque. An over-torque can break the weld between the side bar and the band.

Page 25: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

The cupped lifter bar indicates proper installation torque. View 1 of 2

Page 26: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Displaced metal on washer (left) is the result of proper torque. View 2 of 2

Page 27: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Protrusions on the band show that the finger lugs were placed under the band. Most commonly found on the underside of pipe.

Page 28: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Leak. The bulge on the band shows that debris was trapped under the clamp.

Page 29: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

This repair clamp was used where a coupling should be installed. The indentations on the band show the end of the pipe. See Catalog Section L for proper applications.

Page 30: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

A repair clamp as a "transition" coupling. View 1 of 3

PVC pipe side11.10" (smaller) diameter

Cast iron pipe side likely 11.60" (larger) diameter

Additional stress on the band-to-sidebar weld at the pipe diameter transition area

Sidebar

Page 31: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

A repair clamp as a "transition" coupling. View 2 of 3

PVC pipe side11.10" (smaller) diameter

Cast iron pipe side likely 11.60" (larger) diameter

Broken band-to-sidebar weld

Page 32: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

A repair clamp as a "transition" coupling. View 3 of 3

PVC pipe side Cast iron pipe side

Lifter Bar

Stud

Set of finger lugs

Sidebars

WasherLubricant

Page 33: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

This 3-piece tapping sleeve leaked because the bottom row of bolts was not torqued.

Unequal gap - no gap on left, large gap on right and bottom nuts not torqued.

During installation, tighten so the torque

and gap are equal. This will prevent leaking.

Page 34: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Gasket Displacement - not enough bolt torque was applied during installation.

Page 35: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Coupling End RingOver tightening the fasteners may break the casting. View 1 of 3

Page 36: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Over tightening may deflect the bolts. View 2 of 3

Page 37: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

Over tightening may deflect the casting. View 3 of 3

Page 38: Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -

FORD METER BOX