8 900 SH JAMB 9 MULLION: 900 SH / 900 SH 7 900 SH JAMB 6 MULLION: 900 SH / 328 FIXED 1 900 SH HEAD 2 900 SH SILL 3 MULLION: 328 FIXED / 900 SH 4 900 SH INTERLOCK 5 MULLION: 900 SH / 328 FIXED 4 900 SH INTERLOCK Triple Pane Section Drawing Series 900 Fiberglass Windows Double Hung Rough openings are 1/2" typical all around 45 Higgins Ave. Winnipeg MB R3B 0A8 Tel. 1-204-339-6456 Fax 1-204-334-1800 www.duxtonwindows.com

Triple Pane Section Drawing Rough openings are 1/2 typical

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Triple Pane Section Drawing Rough openings are 1/2 typical

8 900 SH JAMB 9 MULLION: 900 SH / 900 SH

7 900 SH JAMB6 MULLION: 900 SH / 328 FIXED

1 900 SH HEAD

2 900 SH SILL

3 MULLION: 328 FIXED / 900 SH

4 900 SH INTERLOCK5 MULLION: 900 SH / 328 FIXED

4 900 SH INTERLOCK

Triple Pane Section Drawing

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 2: Triple Pane Section Drawing Rough openings are 1/2 typical

1 900 SH HEAD

2 900 SH SILL

3 MULLION: 328 FIXED / 900 SH

4 900 SH INTERLOCK

7 900 SH JAMB6 MULLION: 900 SH / 328 FIXED

8 900 SH JAMB 9 MULLION: 900 SH / 900 SH

5 MULLION: 900 SH / 328 FIXED

4 900 SH INTERLOCK

Dual Pane Section Drawing

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 3: Triple Pane Section Drawing Rough openings are 1/2 typical

2

1

8 7

4

2

1

4

2

1

4

1

4

2 2

4

4

3

3

7

7

7

8

8

9

6

5

6

A B

C D

Typical Elevations

Series 900 Fiberglass Windows

Double Hung

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 4: Triple Pane Section Drawing Rough openings are 1/2 typical

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

1 1/2" FLAT

EXPANDER

PROFILED

BRICKMOLD

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

PROFILED

BRICKMOLD

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

NARROW PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

Triple Pane Narrow Perimeter w/ Brickmold Options

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 5: Triple Pane Section Drawing Rough openings are 1/2 typical

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

1 1/2" FLAT

EXPANDER

PROFILED

BRICKMOLD

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

PROFILED

BRICKMOLD

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

250 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

Triple Pane 250 Panning Perimeter w/ Brickmold Options

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 6: Triple Pane Section Drawing Rough openings are 1/2 typical

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

1 1/2" FLAT

EXPANDER

PROFILED

BRICKMOLD

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

PROFILED

BRICKMOLD

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

1" FLAT

EXPANDER

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

SILL PERIMETER

w/ OPTIONAL

NAILING FIN

Triple Pane Sill Perimeter w/ Brickmold Options

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 7: Triple Pane Section Drawing Rough openings are 1/2 typical

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

1 1/2" FLAT

EXPANDER

PROFILED

BRICKMOLD

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

PROFILED

BRICKMOLD

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

1" FLAT

EXPANDER

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

NEW WIDE PERIMETER

w/ OPTIONAL NAILING FIN

Triple Pane New Wide Perimeter w/ Brickmold Options

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Page 8: Triple Pane Section Drawing Rough openings are 1/2 typical

NEW DUAL PURPOSE1/2" AND 5/8" WHITEDRYWALL RETURNU-CHANNEL

3/4" WHITEDRYWALL RETURNU-CHANNEL

CELLULAR JAMB LINER PCH JAMB LINER

OTHER WOOD JAMB LINER

Triple Pane Jamb & Interior Options

Series 900 Fiberglass Windows

Double Hung

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

AutoCAD SHX Text
14" TO 7 "916"
AutoCAD SHX Text
14" TO 4 "12"
AutoCAD SHX Text
" TO 10"14" TO 10"
Page 9: Triple Pane Section Drawing Rough openings are 1/2 typical

NOSING PERIMETER

w/ OPTIONAL NAILING FIN

350 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

450 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

600 PANNING PERIMETER

w/ OPTIONAL NAILING FIN

NARROW PERIMETER WITH 1" FLAT EXPANDER

(HEAD/JAMB)

SILL ON BOTTOM, NAILING FLANGE REMOVED ON SITE

USED IN CONJUNCTION TO REPLACE WOOD WINDOWS

WITH A SILL DETAIL

NARROW PERIMETER w/ SILL

Other Perimeter Options

Series 900 Fiberglass Windows

Double Hung

Rough openings are 1/2" typical all around

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

AutoCAD SHX Text
3 [83]14 [83]
Page 10: Triple Pane Section Drawing Rough openings are 1/2 typical

Installation Clips

Installation Clip

45 Higgins Ave.

Winnipeg MB R3B 0A8

Tel. 1-204-339-6456

Fax 1-204-334-1800

www.duxtonwindows.com

Series 900 Fiberglass Windows

Double Hung

AutoCAD SHX Text
CORNER ANCHORS - SECURE APPROXIMATELY 4" FROM THE CORNERS PERIMETER ANCHORS - SPACING SHOULD NOT EXCEED 24" APART CENTER TO CENTER MULLION AND TRANSOM ANCHORS - ALWAYS ANCHOR WITHIN 4" OF MULLION OR TRANSOM INSTALL CLIPS THAT SNAP INTO PLACE NO SCREWS IN FRAME (D)
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D