7/22/2019 TR 73U Datasheet
1/2
T&D Corporation
The TR-73U has all the great features of TandDs TR-72U temperatureand humidity data logger plus a third channel for monitoring and recordingambient pressure. This compact unit has a large 4 digit LCD display forreading current values that can be set to show any single channel, or allthree on a rotating basis. The logger can store up to 8,000 sample triplets,operates on a single AA battery and incorporates a USB interface for rapid
data downloading. As with all of TandDs data loggers, the TR-73U shipscomplete with software, sensor and cable included.
Temperature, Humidity and Ambient Pressure
Three Channel Data Logger
TR-73U
7/22/2019 TR 73U Datasheet
2/2
Software SpecificationsT&D Recorder for Windows
TR-71U TR-72U TR-73U
Recording Start (Programmed Start / Immediate Start) Recording Stop
Main Unit Settings (Recording Interval Recording Method Upper and Lower Limits)
Downloading of Recorded Data
Temperature and Humidity Graphs for each Channel
Zoom in, out and scroll with mouse or keyboard
Change Channel Colors Turn ON and OFF Channel Display
Channel Name Recording Interval Number of Readings
Highest, Lowest and Average Readings Unit of Measurement.
AB Cursor Dates, Times and Data Readings
Calculated Difference between Cursor A and B
8 Channel Simultaneous Display and Processing
Possible to process mixed data from TR-71U and TR-72U units. (up to 4units.)
Data List Display Calculation Range Settings Data Maintenance
Edit Recording Conditions Delete Data by Channel
Re-order Data by Channel
Serial Port Auto Find Function
T&D Common Data File Text File (CSV, etc)
(Selected Range or File for Entire Period)
Graphs / Tables
Microsoft Windows 2000 / XP English
Microsoft Windows 98 / Me E nglish
Microsoft WindowsNT 4.0 English **1
IBM Compatible with higher than Pentium 90MHz
USB Port (1.0 / 1.1)
More than 16MB
More than 4 MB of free space (Data will need more space)
VGA (640 480) more than 256 colors
Software
Compatible Devices
Communication
Functions
Temp/Humidity Graph
Graph Display
Data Display
Number of Channels
Others
Other
File Output
Printing
Compatible OS
PC/CPU
Memory
Hard Disk
Monitor
**1: USB communication with TR-71U / 72U data loggers cannot be carried out using WindowsNT4.0.
1, 2, 5, 10, 15, 20, 30 Seconds / 1, 2, 5, 10, 15, 20, 30, 60 Minutes- Total of 15 choices
8,000 Readings 2 or 3 Channels
Endless Loop Method (Overwrite from the oldest data when recording capacity is full)
One Time Method (Stop recording when recording capacity is full)
Measurements, (Any Single Channel or alternating display of all Channels),
Recording Status, Battery Life Warning, Amount of Recorded Data, Unit of Measurement
AA alkaline battery (LR6)
Approx. 1 year**2
Activated when battery power is low or when switch is off (Approx. 1 year)
USB Communication Cable (included)
Approximately 8 seconds (For full memory)
H55mm W78mm D18mm
About 62g (Including one AA battery)
-10 to 60C, 90% RH (non-condensing)
TR-3100 External Temperature & Humidity Sensor
AA alkaline Battery (LR6), User's Manual,
USB Cable (US-15C ; length 1.5m), Software CD Set
Pressure
1 Channel
750 to 1100 hPa
---
---
1.5% hPa
0.1 hPa
Atmospheric
Pressure Sensor
4 Sec. **1
Humidity
1 Channel
---
10 to 95% RH
---
5% RH
(25C, 50% RH)
1% RH
Macromolecular
---
Temperature
1 Channel
-10 to 60C
0 to 50C
-40 to 110C
0.3% (0 to 50C)
0.5% (-40 to -20 / 80 to 110C)
0.1C
Thermistor
12 Sec.
TR-73U
Measurement Parameter
Measurement Channel
Internal Sensor
Standard External Sensor
Optional External Sensor
Measurement Accuracy
Display Resolution
Sensor Type
Internal Sensor Time Constant
Recording Interval
Recording Capacity
Recording Mode
LCD Display
Power
Battery Life
Data Back-up
Communication Interface
Data Download Time
Dimensions
Weight
Operating Environment
Standard Sensor (Included)
Accessories
included in package
**1 Pressure time constant is 40 seconds for sample rates of one minute or longer.**2 Battery life of TR-73U is approximately 10 months.
Product Specifications
Web Site T&D OnlineProduct information, FAQ and software update downloads.
http://www.tandd.com/
TandD US, LLC.Phone: (518) 669-9227
Fax: (413) 639-9227E-mail: [email protected]
5652-169 Sasaga Matsumoto City.
Nagano 399-0033 Japan
Facsimile(+81)263-26-4281
E-mail: [email protected]
T&D Corporation
System Setup
Output
Standard Humidity
and Temperature Sensor
(TR-3100)
Software
(T&D Recorder for Windows)
Printout
Install
ConnectConnect
Insert
AA Alkaline battery
LR6 x 1
Text FileUSB Communication Cable
US-15C
TR-73U
Easy to Read Multi-Functional DisplayThe easy to read LCD displays current readings , recording condit ion,
bat te ry li fe wa rn in g, an d un it o f me as ure me nt .
(1) Re cording condition:
ON:Recording in progress. BLINKING:Waiting for programmed start.
(2) Memory status:
After every 2000 readings the scale will increment from left to right.
(3) Data communication.
ON: USB cable is connected. BLINKING: Data is being transferred.
(4) ONTIME:When the number of recorded readings reaches 8000, "FULL"will appear in the
unit's LCD display and recording will automatically stop.
ENDLESS:When the number of recorded readings reaches 8000, the oldest data reading will
be ove rwr it ten and rec ord ing wil l c ont inu e.
(5) When the battery power becomes low, this will appear in the LCD display. If the batterypow er bec ome s e ven low er, SLP wil l a ppe ar and nor mal ope rat ion s w ill sto p. If the
signal appears, please change the battery as soon as possible.
(6) The unit of measurement (C, F, %, hPa) for the display will appear.
(7) Current measurements or operationa l messages such as FULL or SLP will appear.
(1) (2) (3) (4) (5)
(6)
(7)