RS908KB12 Correlation Report for FSL-TJN-FM to KES-CHINA Final Test Site Expansion Page 1 of 46 There are four correlation reports in this file, products list as below: 1. RS908KB12 2. MC908AP64 3. MC56F8002(6) 4. 9S08RG60 1. Objective: This report details the correlation result of the RS908KB12(SOIC8/16/20, TSSOP16, QFN-D 8EP) device to demonstrate the KES-CHINA Final Tianjin, China, Test facility correlates with the current FSL-TJN-FM Final Tianjin, China, Test facility. The correlation units were first tested at the current FSL-TJN-FM Final Test facility and then both rejects and good units were tested at the KES-CHINA Final Test facility. 2. General Information Correlation Lot Information: Lot # Qty. XG931BDR00 1248 XG922AN400 1254 LJNJ02906Y00 1030 YZME00KB2A01 1326 T90X78230102 38 3. Qualification Plan: 3.1 Requirements: The requirements and acceptance criteria were based on the Freescale specification 12MQS10009G. Correlation Plan Name Detail Description Qual per Correlatio n Plan, (Y / N ?) Acceptance Criteria a Bin-to-bin Correlation Goal: Correlate bin-to-bin per production test flow Lot quantity: 1 per package Units per lot: 1000 Temperature: 25C Type of units: good, rejects Y 100% correlation for all good and reject units.

There are four correlation reports in this file, products list as … · 2013. 10. 23. · RS908KB12 Correlation Report for FSL-TJN-FM to KES-CHINA Final Test Site Expansion Page

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 1 of 46

    There are four correlation reports in this file, products list as below: 1. RS908KB12 2. MC908AP64 3. MC56F8002(6) 4. 9S08RG60

    1. Objective:

    This report details the correlation result of the RS908KB12(SOIC8/16/20, TSSOP16,

    QFN-D 8EP) device to demonstrate the KES-CHINA Final Tianjin, China, Test facility correlates with the current FSL-TJN-FM Final Tianjin, China, Test facility. The correlation units were first tested at the current FSL-TJN-FM Final Test facility and then both rejects and good units were tested at the KES-CHINA Final Test facility.

    2. General Information

    • Correlation Lot Information:

    Lot # Qty.

    XG931BDR00 1248

    XG922AN400 1254

    LJNJ02906Y00 1030

    YZME00KB2A01 1326

    T90X78230102 38

    3. Qualification Plan: 3.1 Requirements: The requirements and acceptance criteria were based on the Freescale specification 12MQS10009G.

    Correlation Plan

    Name Detail Description

    Qual per Correlation Plan, (Y / N ?)

    Acceptance Criteria

    a Bin-to-bin

    Correlation

    Goal: Correlate bin-to-bin per

    production test flow

    Lot quantity: 1 per package

    Units per lot: 1000

    Temperature: 25C

    Type of units: good, rejects

    Y 100% correlation for all good and reject units.

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 2 of 46

    Site: FSL-TJN-FM / KES-CHINA

    b QA Gate Qual

    Goal: 100% QC Gate, 0 failures

    Lot quantity: 4

    Units per lot: 1000

    Temperature: Hot, Cold

    Type of units: good

    Site: KES-CHINA

    Y 0 failures.

    c Parametric

    Comparison

    Goal: Parametric comparison for

    Identify Parametric Tests

    Lot quantity: 4

    Units per lot: 30

    Temperature: 25C

    Type of units: good

    Site: FSL-TJN-FM/ KES-CHINA

    Y

    t-test and f-test should not demonstrate significant

    difference. P-Unit of Measure

    should be greater than 0.05.

    3.2 General Method: Using the production test program, perform 100% screening of 5 lots at 25C temperature, in the current FSL-TJN-FM. Test the same lots under the same conditions in KES-CHINA. Any miss-correlations at the KES-CHINA are sent to FSL-TJN-FM for evaluation.

    4.0 Correlation/Qualification Results:

    4.1 Bin-to-bin Correlation Results: Tables below summarize the correlation results. All numbers filled in green boxes means correlation was achieved. All numbers filled in yellow boxes means results did not correlate and requires further explanation.

    Bin-to-Bin Correlation Matrix for Hot& Room Test

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 3 of 46

    XG931BDR00

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    XG922AN400

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    LJNJ02906Y00

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 4 of 46

    YZME00KB2A01

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    T90X78230102

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    Results: Pass 4.2 QA Gate results (tested at spec limits):

    Table below shows the QA Gate results Qual in KES-CHINA.

    QA Gate Results

    QA Gate Hot 95 C Cold -40C

    Lot # Pass # Fail # Pass # Fail

    XG931BDR00 100% 0 100% 0

    XG922AN400 100% 0 100% 0

    LJNJ02906Y00 100% 0 100% 0

    YZME00KB2A01 100% 0 100% 0

    Results: Pass

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 5 of 46

    4.3 Parametric Comparison:

    Tables below summarize the parametric data on 30 good units. The following are significant parameters chosen for this comparison:

    • mcu_9kb12_ridd_hv

    • mcu_9kb12_sidd_off_hv

    XG931BDR00 mcu_9kb12_ridd_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 3.5650 3.5657 16 3.6556 3.6543

    2 3.6018 3.5977 17 3.6986 3.7062

    3 3.5702 3.5754 18 3.6772 3.6784

    4 3.5470 3.5492 19 3.5773 3.5887

    5 3.4745 3.5097 20 3.6012 3.5927

    6 3.4219 3.4201 21 3.5760 3.5767

    7 3.5629 3.5519 22 3.6291 3.6326

    8 3.5045 3.5187 23 3.5437 3.5222

    9 3.4701 3.4813 24 3.6956 3.6984

    10 3.4676 3.4738 25 3.7387 3.7268

    11 3.6527 3.6496 26 3.6760 3.6678

    12 3.5665 3.5705 27 3.6056 3.6058

    13 3.6269 3.6156 28 3.6031 3.5998

    14 3.7354 3.7226 29 3.6205 3.6095

    15 3.6274 3.6320 30 3.6565 3.6657

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 6 of 46

    mcu_9kb12_sidd_off_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 1.4467 1.4286 16 1.0232 1.0864

    2 1.3478 1.3623 17 1.0840 1.0874

    3 1.2848 1.2934 18 1.1743 1.1711

    4 1.3274 1.3082 19 1.3722 1.3954

    5 1.3430 1.3337 20 1.2360 1.2705

    6 1.2309 1.2379 21 1.1355 1.1634

    7 1.2533 1.2878 22 1.2273 1.2333

    8 1.4625 1.4623 23 1.0695 1.0864

    9 1.2702 1.2919 24 1.2403 1.2725

    10 1.2043 1.2190 25 1.3620 1.3919

    11 1.2018 1.2001 26 1.1395 1.1649

    12 1.3671 1.3944 27 1.5207 1.4713

    13 1.3457 1.3468 28 1.2038 1.2037

    14 1.2153 1.2241 29 1.4053 1.4106

    15 1.3483 1.3705 30 1.1084 1.1593

    25C mcu_9kb12_ridd_hv mcu_9kb12_sidd_off_hv t- test (P-value) 0.986 0.678 f- test (P-value) 0.804 0.626

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 7 of 46

    XG922AN400 mcu_9kb12_ridd_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 3.6656 3.6623 16 3.7204 3.7378

    2 3.5320 3.5599 17 3.6668 3.6752

    3 3.4694 3.4775 18 3.6663 3.6702

    4 3.5794 3.5920 19 3.7171 3.7257

    5 3.6850 3.6991 20 3.6517 3.6537

    6 3.6787 3.6852 21 3.6799 3.6877

    7 3.6004 3.6049 22 3.6861 3.7124

    8 3.6766 3.6816 23 3.6698 3.6774

    9 3.5285 3.5447 24 3.5551 3.5666

    10 3.7303 3.7557 25 3.5659 3.5874

    11 3.4903 3.4930 26 3.5645 3.5839

    12 3.6783 3.6841 27 3.5971 3.6027

    13 3.7085 3.7154 28 3.6316 3.6168

    14 3.6069 3.6120 29 3.7095 3.7214

    15 3.5892 3.5934 30 3.6713 3.6776

    mcu_9kb12_sidd_off_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 1.0937 1.0724 16 1.2961 1.2754

    2 1.0985 1.0748 17 1.1974 1.2111

    3 0.8874 0.9600 18 1.0285 1.0146

    4 1.1290 1.1149 19 1.3017 1.2759

    5 1.2268 1.2310 20 1.1872 1.1927

    6 1.1846 1.1631 21 1.1060 1.0792

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 8 of 46

    7 1.2385 1.2611 22 1.2262 1.2244

    8 1.1870 1.1877 23 1.1495 1.1317

    9 1.2300 1.2522 24 1.0454 1.0644

    10 1.1681 1.1624 25 1.1987 1.2144

    11 1.3100 1.2916 26 1.1510 1.1424

    12 0.9552 0.9681 27 1.2309 1.2532

    13 1.1355 1.1169 28 1.1080 1.0818

    14 1.1117 1.0890 29 1.2346 1.2581

    15 1.0107 1.0011 30 1.0321 1.0339

    25C mcu_9kb12_ridd_hv mcu_9kb12_sidd_off_hv t- test (P-value) 0.608 0.938 f- test (P-value) 0.988 0.869

    LJNJ02906Y00 mcu_9kb12_ridd_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 3.6281 3.6483 16 3.5017 3.5568

    2 3.4839 3.5125 17 3.5658 3.5850

    3 3.4937 3.5446 18 3.6133 3.6287

    4 3.6044 3.6263 19 3.5946 3.6175

    5 3.5644 3.5784 20 3.6449 3.6617

    6 3.6050 3.6276 21 3.5652 3.5801

    7 3.6608 3.6763 22 3.5933 3.6077

    8 3.5484 3.5627 23 3.6145 3.6360

    9 3.5574 3.5724 24 3.5726 3.5911

    10 3.6270 3.6441 25 3.6016 3.6235

    11 3.6306 3.6497 26 3.5864 3.6064

    12 3.5609 3.5737 27 3.4787 3.4930

    13 3.5539 3.5642 28 3.5863 3.6052

    14 3.5735 3.5928 29 3.5243 3.5612

    15 3.5832 3.6016 30 3.6877 3.6790

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 9 of 46

    mcu_9kb12_sidd_off_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 1.2083 1.2910 16 1.6699 1.6316

    2 1.5254 1.5685 17 1.7168 1.6791

    3 1.9220 1.8540 18 1.5290 1.5689

    4 1.2798 1.2936 19 1.2956 1.3655

    5 1.7663 1.7025 20 1.6397 1.6102

    6 1.3477 1.4216 21 1.3314 1.4201

    7 1.6570 1.6164 22 1.5213 1.5608

    8 1.1945 1.2879 23 1.4907 1.5582

    9 1.2813 1.3482 24 1.4126 1.4822

    10 1.6264 1.6097 25 1.3850 1.4516

    11 1.3237 1.3941 26 1.5417 1.5801

    12 1.3120 1.3818 27 1.3921 1.4583

    13 1.3140 1.3941 28 1.6882 1.6403

    14 1.7066 1.6587 29 1.5663 1.6000

    15 1.3263 1.4007 30 1.6453 1.6123

    25C mcu_9kb12_ridd_hv mcu_9kb12_sidd_off_hv t- test (P-value) 0.108 0.523 f- test (P-value) 0.533 0.127

    YZME00KB2A01 mcu_9kb12_ridd_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 10 of 46

    1 3.4339 3.4293 16 3.5147 3.5369

    2 3.5468 3.5419 17 3.5662 3.5771

    3 3.5322 3.5388 18 3.5846 3.5941

    4 3.5506 3.5496 19 3.5112 3.5272

    5 3.5064 3.5060 20 3.5660 3.5752

    6 3.4783 3.4757 21 3.5077 3.5099

    7 3.4826 3.4771 22 3.5039 3.5059

    8 3.4107 3.4184 23 3.4863 3.4837

    9 3.4705 3.4642 24 3.4191 3.4210

    10 3.5033 3.5003 25 3.5915 3.5989

    11 3.4255 3.4276 26 3.5516 3.5667

    12 3.4185 3.4188 27 3.4839 3.4817

    13 3.4655 3.4630 28 3.4447 3.4387

    14 3.5511 3.5599 29 3.4232 3.4213

    15 3.3858 3.4007 30 3.4724 3.4654

    mcu_9kb12_sidd_off_hv Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 1.3582 1.3832 16 1.5633 1.4879

    2 1.4062 1.3914 17 1.3174 1.2499

    3 1.2399 1.1504 18 1.4107 1.3965

    4 1.4507 1.4777 19 1.2909 1.2132

    5 1.3376 1.3469 20 1.3919 1.3868

    6 1.4970 1.4828 21 1.4410 1.4138

    7 1.3438 1.3561 22 1.1908 1.1259

    8 1.6087 1.5553 23 1.6307 1.5665

    9 1.2720 1.1601 24 1.4091 1.3939

    10 1.4260 1.4103 25 1.4072 1.3919

    11 1.3210 1.2673 26 1.4153 1.4036

    12 1.4283 1.4108 27 1.5948 1.5103

    13 1.6563 1.6119 28 1.3103 1.2254

    14 1.4618 1.4797 29 1.6109 1.5568

    15 1.3208 1.2653 30 1.2760 1.1836

  • RS908KB12 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 11 of 46

    25C mcu_9kb12_ridd_hv mcu_9kb12_sidd_off_hv t- test (P-value) 0.847 0.257 f- test (P-value) 0.749 0.660

    Results: Pass

    5.0 Analysis Conclusions and Verification � Bin-to-bin activity shows 100% correlation of 4896 units at Room temperature between the new KES-

    CHINA and the current FSL-TJN-FM.

    � The QA Gate correlation passes at KES-CHINA.

    � Parametric comparison between new KES-CHINA and the current FSL-TJN-FM for 30 good units

    passes. The results demonstrate that the new KES-CHINA Final Test Site has qualified as a test site for this

    product.

    6.0 Document History:

    Rev Date Originator

    O 20 Oct 2010

    Ji Chang (KES-CHINA, TPE)

    Zhang Xuewei (TJN MSG PE)

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 12 of 46

    1. Objective:

    This report details the correlation result of the MC908AP64/64A (LQFP48) device to demonstrate the KES-CHINA Tianjin, China, Final Test facility correlates with the current FSL-TJN-FM Tianjin, China, Final Test facility. The correlation units were first tested at the current FSL-TJN-FM Final Test facility and then both rejects and good units were tested at the KES-CHINA Final Test facility.

    2. General Information

    • Correlation Lot Information:

    Lot # Qty.

    TJMEA0RBEK01 1200

    TJMEA0R7VQ01 1200

    TJMEA0RBVU01 1200

    3. Qualification Plan: 3.1 Requirements: The requirements and acceptance criteria were based on the Freescale specification 12MQS10009G.

    Correlation Plan

    Name Detail Description

    Qual per Correlation Plan, (Y / N ?)

    Acceptance Criteria

    a Bin-to-bin

    Correlation

    Goal: Correlate bin-to-bin per

    production test flow

    Lot quantity: 3

    Units per lot: 1000

    Temperature: 95C, 25C

    Type of units: good, rejects

    Site: FSL-TJN-FM / KES-CHINA

    Y 100% correlation for all good and reject units.

    b QA Gate Qual

    Goal: 100% QC Gate, 0 failures

    Lot quantity: 3

    Units per lot: 1000

    Temperature: Hot, Cold

    Type of units: good

    Site: KES-CHINA

    Y 0 failures.

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 13 of 46

    c Parametric

    Comparison

    Goal: Parametric comparison for

    Identify Parametric Tests

    Lot quantity: 2

    Units per lot: 30

    Temperature: 95C, 25C

    Type of units: good

    Site: FSL-TJN-FM/ KES-CHINA

    Y

    t-test and f-test should not demonstrate significant

    difference. P-Unit of Measure

    should be greater than 0.05.

    3.2 General Method: Using the production test program, perform 100% screening of 3 lots at 95C, 25C temperature, in the current FSL-TJN-FM. Test the same lots under the same conditions in KES-CHINA. Any miss-correlations at KES-CHINA are sent FSL-TJN-FM for evaluation.

    4.0 Correlation/Qualification Results:

    4.1 Bin-to-bin Correlation Results: Tables below summarize the correlation results. All numbers filled in green boxes means correlation was achieved. All numbers filled in yellow boxes means results did not correlate and requires further explanation.

    Bin-to-Bin Correlation Matrix for Hot& Room Test

    TJMEA0RBEK01

    FHNCAS KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 14 of 46

    FRNCAS KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    TJMEA0R7VQ01

    FHNCAS KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    TJMEA0RBVU01

    FHNCAS KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    Results: Pass 4.2 QA Gate results (tested at spec limits):

    Table below shows the QA Gate results Qual in KES-CHINA.

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 15 of 46

    QA Gate Results

    QA Gate Hot 95 C Cold -40C

    Lot # Pass # Fail # Pass # Fail

    TJMEA0RBEK01 100% 0 100% 0

    TJMEA0R7VQ01 100% 0 100% 0

    TJMEA0RBVU01 100% 0 100% 0

    Results: Pass

    4.3 Parametric Comparison:

    Tables below summarize the parametric data on 30 good units. The following are significant parameters chosen for this comparison:

    • Vdd_rampup (hot,room)

    • sidd_ram_lvitb_ VDD(hot)

    • check_LVIT_vdd_ Vdd(hot, room)

    TJMEA0RBEK01

    Vdd_rampup Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

    1 4.9938 4.9748 16 4.9822 4.9744

    2 4.9951 4.9760 17 4.9805 5.0020

    3 5.0071 5.0172 18 5.0039 4.9835

    4 5.0174 4.9983 19 5.0081 5.0077

    5 4.9764 4.9685 20 4.9816 5.0041

    6 5.0171 4.9957 21 4.9774 4.9716

    7 5.0032 5.0119 22 4.9957 4.9773

    8 5.0040 4.9840 23 5.0087 4.9901

    9 5.0039 5.0053 24 4.9828 5.0046

    10 5.0087 4.9881 25 4.9833 4.9747

    11 4.9814 4.9727 26 5.0042 4.9863

    12 4.9957 5.0064 27 5.0103 5.0122

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 16 of 46

    13 5.0090 4.9915 28 4.9744 4.9684

    14 4.9799 5.0019 29 4.9836 4.9948

    15 5.0128 4.9939 30 4.9998 4.9776

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

    1 4.9993 4.8106 16 4.9933 4.9899

    2 4.5184 4.5695 17 4.5265 4.4810

    3 4.9968 4.7993 18 5.0121 4.8227

    4 4.5247 4.5810 19 4.5212 4.5781

    5 5.0043 5.0183 20 5.0008 5.0147

    6 4.5272 4.7823 21 4.5222 4.4788

    7 4.9977 4.8005 22 4.9955 4.7940

    8 4.5275 4.5841 23 4.5206 4.5778

    9 4.9964 4.8971 24 4.9999 4.8113

    10 4.5300 4.5885 25 4.5275 4.5173

    11 4.9961 4.7956 26 4.9939 4.7901

    12 4.5190 4.5753 27 4.5309 4.5895

    13 4.5275 4.5868 28 5.0039 5.0018

    14 4.9955 4.9915 29 4.5231 4.4806

    15 4.5303 4.7888 30 4.9986 4.9103

    sidd_ram_lvitb_ VDD Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 1.7428 1.7398 16 1.7560 1.7541

    2 1.7264 1.7264 17 1.7624 1.7615

    3 1.7384 1.7396 18 1.7443 1.7406

    4 1.6973 1.7085 19 1.7164 1.7258

    5 1.7349 1.7370 20 1.6592 1.6804

    6 1.7446 1.7457 21 1.7344 1.7355

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 17 of 46

    7 1.7550 1.7528 22 1.7208 1.7258

    8 1.7088 1.7143 23 1.7767 1.7711

    9 1.7137 1.7230 24 1.6984 1.7096

    10 1.7721 1.7656 25 1.7793 1.7821

    11 1.7053 1.7132 26 1.6984 1.7105

    12 1.7596 1.7591 27 1.7527 1.7487

    13 1.7568 1.7566 28 1.7295 1.7299

    14 1.7594 1.7586 29 1.6889 1.7056

    15 1.7527 1.7472 30 1.7239 1.7263

    check_LVIT_vdd_ Vdd Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

    1 3.12 3.12 16 3.14 3.14

    2 3.12 3.12 17 3.12 3.12

    3 3.14 3.13 18 3.13 3.13

    4 3.11 3.10 19 3.09 3.09

    5 3.14 3.14 20 3.04 3.05

    6 3.17 3.16 21 3.11 3.11

    7 3.14 3.14 22 3.12 3.12

    8 3.11 3.11 23 3.14 3.14

    9 3.13 3.13 24 3.05 3.07

    10 3.15 3.15 25 3.17 3.16

    11 3.11 3.11 26 3.11 3.12

    12 3.12 3.12 27 3.15 3.15

    13 3.13 3.13 28 3.11 3.12

    14 3.16 3.15 29 3.11 3.12

    15 3.11 3.11 30 3.12 3.13

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 18 of 46

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

    1 3.10 3.10 16 3.12 3.11

    2 3.07 3.06 17 3.11 3.10

    3 3.16 3.11 18 3.04 3.05

    4 3.07 3.06 19 3.04 3.06

    5 3.10 3.10 20 3.04 3.06

    6 3.07 3.06 21 3.07 3.07

    7 3.08 3.08 22 3.08 3.08

    8 3.06 3.06 23 3.07 3.07

    9 3.07 3.06 24 3.09 3.09

    10 3.01 3.00 25 3.05 3.06

    11 3.04 3.00 26 3.09 3.10

    12 3.08 3.08 27 3.08 3.08

    13 3.09 3.08 28 3.07 3.07

    14 3.10 3.10 29 3.12 3.11

    15 3.03 3.00 30 3.08 3.08

    95C Vdd_rampup sidd_ram_lvitb_ VDD check_LVIT_vdd_ Vdd t- test (P-value) 0.133 0.671 0.922 f- test (P-value) 0.654 0.220 0.372 25C Vdd_rampup check_LVIT_vdd_ Vdd t- test (P-value) 0.605 0.554 f- test (P-value) 0.104 0.907

    TJMEA0RBVU01

    Vdd_rampup Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 19 of 46

    1 5.0425 5.0353 16 5.0251 5.0249

    2 5.0176 5.0219 17 4.9926 4.9860

    3 4.9898 5.0144 18 5.0214 5.0226

    4 5.0205 4.9922 19 5.0304 5.0298

    5 5.0319 5.0300 20 5.0167 5.0203

    6 4.9901 5.0160 21 5.0344 5.0302

    7 5.0252 5.0264 22 4.9895 5.0141

    8 5.0182 4.9919 23 5.0252 5.0278

    9 4.9989 5.0191 24 4.9979 5.0173

    10 5.0205 5.0226 25 5.0217 5.0235

    11 5.0375 5.0407 26 5.0391 4.9937

    12 4.9939 5.0166 27 4.9939 5.0169

    13 5.0170 5.0210 28 5.0236 5.0248

    14 5.0288 5.0193 29 4.9892 5.0132

    15 5.0183 5.0221 30 5.0286 5.0292

    sidd_ram_lvitb_ VDD Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 976.338 958.720 16 928.365 933.604

    2 932.254 935.001 17 926.358 933.005

    3 962.023 956.646 18 920.158 930.921

    4 951.706 950.097 19 951.841 950.811

    5 967.662 976.683 20 922.194 932.494

    6 955.399 953.948 21 940.614 945.323

    7 910.491 920.472 22 930.944 934.738

    8 930.723 934.024 23 917.614 918.371

    9 932.472 936.068 24 927.887 933.604

    10 936.441 939.132 25 919.649 930.744

    11 946.228 949.079 26 943.165 947.515

    12 939.605 939.402 27 923.810 932.700

    13 919.649 929.431 28 927.282 933.513

    14 947.248 949.552 29 934.001 937.041

    15 922.194 932.491 30 935.932 938.700

  • MC908AP64/64A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 20 of 46

    check_LVIT_vdd_ Vdd Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (v) (v)

    Pat#

    (v) (v)

    1 2.36 2.36 16 2.30 2.30

    2 2.36 2.36 17 2.30 2.30

    3 2.35 2.34 18 2.34 2.34

    4 2.36 2.36 19 2.33 2.32

    5 2.35 2.34 20 2.30 2.30

    6 2.34 2.33 21 2.31 2.31

    7 2.34 2.33 22 2.35 2.35

    8 2.34 2.33 23 2.30 2.31

    9 2.33 2.32 24 2.32 2.32

    10 2.35 2.34 25 2.33 2.32

    11 2.34 2.34 26 2.33 2.32

    12 2.35 2.34 27 2.35 2.35

    13 2.33 2.32 28 2.33 2.33

    14 2.35 2.35 29 2.32 2.32

    15 2.34 2.34 30 2.34 2.34

    95C Vdd_rampup sidd_ram_lvitb_ VDD check_LVIT_vdd_ Vdd t- test (P-value) 0.472 0.300 0.431 f- test (P-value) 0.151 0.160 0.801

    Results: Pass

    5.0 Analysis Conclusions and Verification � Bin-to-bin activity shows 100% correlation of 3600 units at Room and Hot temperature between the new

    KES-CHINA and the current FSL-TJN-FM.

    � The QA Gate correlation passes at KES-CHINA.

  • MC908AP64/A Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 21 of 46

    � Parametric comparison between new KES-CHINA and the current FSL-TJN-FM for 30 good units,

    passes. The results demonstrate that the new KES-CHINA Final Test Site has qualified as a test site for this

    product.

    6.0 Document History:

    Rev Date Originator

    O 24 Oct 2010

    Ji Chang (KES-CHINA, TPE)

    Shao Christina (TJN MSG PE)

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 22 of 46

    1. Objective:

    This report details the correlation result of the MC56F8002/6 (SOIC28, LQFP32,

    LQFP48) device to demonstrate the KES-CHINA Tianjin, China, Final Test facility correlates with the current FSL-TJN-FM Tianjin, China, Final Test facility. The correlation units were first tested at the current FSL-TJN-FM Final Test facility and then both rejects and good units were tested at the KES-CHINA Final Test facility.

    2. General Information

    • Correlation Lot Information:

    Lot # Qty.

    ME0052E100 1205

    ME00522R00 1107

    ME00522Q00 1118

    3. Qualification Plan: 3.1 Requirements: The requirements and acceptance criteria were based on the Freescale specification 12MQS10009G.

    Correlation Plan

    Name Detail Description

    Qual per Correlation Plan, (Y / N ?)

    Acceptance Criteria

    a Bin-to-bin

    Correlation

    Goal: Correlate bin-to-bin per

    production test flow

    Lot quantity: 1 per package

    Units per lot: 1000

    Temperature: 125C, -40C

    Type of units: good, rejects

    Site: FSL-TJN-FM / KES-CHINA

    Y 100% correlation for all good and reject units.

    b QA Gate Qual

    Goal: 100% QC Gate, 0 failures

    Lot quantity: 3

    Units per lot: 1000

    Temperature: Hot , Cold

    Type of units: good

    Site: KES-CHINA

    Y 0 failures.

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 23 of 46

    c Parametric

    Comparison

    Goal: Parametric comparison for

    Identify Parametric Tests

    Lot quantity: 1 per package

    Units per lot: 30

    Temperature: 125C, -40C

    Type of units: good

    Site: FSL-TJN-FM/ KES-CHINA

    Y

    t-test and f-test should not demonstrate significant

    difference. P-Unit of Measure

    should be greater than 0.05.

    3.2 General Method: Using the production test program, perform 100% screening of 3 lots at 125C and -40C temperature, in the current FSL-TJN-FM. Test the same lots under the same conditions in KES-CHINA. Any miss-correlations at KES-CHINA are sent to FSL-TJN-FM for evaluation.

    4.0 Correlation/Qualification Results:

    4.1 Bin-to-bin Correlation Results: Tables below summarize the correlation results. All numbers filled in green boxes means correlation was achieved. All numbers filled in yellow boxes means results did not correlate and requires further explanation.

    Bin-to-Bin Correlation Matrix for Hot& Room Test

    ME0052E100

    FHN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 24 of 46

    FCN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    ME00522R00

    FHN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    FCN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 25 of 46

    ME00522Q00

    FHN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    FCN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    Results: Pass 4.2 QA Gate results (tested at spec limits):

    Table below shows the QA Gate results Qual in KES-CHINA.

    QA Gate Results

    QA Gate Hot 125 C Cold -40C

    Lot # Pass # Fail # Pass # Fail

    ME0052E100 100% 0 100% 0

    ME00522R00 100% 0 100% 0

    ME00522Q00 100% 0 100% 0

    Results: Pass

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 26 of 46

    4.3 Parametric Comparison: Tables below summarize the parametric data on 30 good units. The following are significant parameters chosen for this comparison:

    • idd_ppd_xtal_vddio_ti

    • idd_lprun_vddio_ti

    ME0052E100

    idd_ppd_xtal_vddio_ti Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 164.2832 167.0730 16 158.3249 153.6010

    2 159.1930 155.7940 17 167.1314 167.6650

    3 159.9970 166.0430 18 157.5436 164.0600

    4 159.0398 158.7810 19 167.2182 167.9140

    5 164.8631 167.2380 20 164.5780 167.2260

    6 158.4372 165.4420 21 167.6959 168.0880

    7 164.0023 162.9310 22 162.7064 160.6790

    8 158.3300 164.8380 23 167.8287 168.1100

    9 164.1504 166.9380 24 162.4843 166.5660

    10 157.6559 154.3250 25 170.6053 169.5380

    11 166.6614 167.5910 26 162.5124 156.6760

    12 158.3785 154.8400 27 166.4774 167.5600

    13 167.5631 167.9190 28 162.1498 166.0620

    14 158.3887 165.4290 29 167.9539 168.3300

    15 169.5018 168.6720 30 162.4741 161.4260

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 27 of 46

    1 147.8943 148.4097 16 147.1412 147.0960

    2 148.0119 148.5387 17 147.3937 147.3235

    3 148.4844 149.6875 18 145.3028 145.7685

    4 148.2366 148.9991 19 146.7116 146.4521

    5 148.0782 148.5463 20 144.8330 144.9160

    6 147.5012 147.3676 21 147.3732 147.1838

    7 146.2518 146.1285 22 146.5948 146.1616

    8 147.5012 147.3726 23 146.9339 146.6850

    9 146.9236 146.5711 24 148.3872 149.4629

    10 147.2382 147.1138 25 148.2979 149.1830

    11 147.9735 148.4932 26 148.1804 148.9319

    12 148.3387 149.4169 27 144.8418 145.2732

    13 147.2506 147.1829 28 147.7029 147.4203

    14 147.5344 147.4080 29 144.8112 144.8430

    15 148.7322 150.4890 30 145.3156 146.0851

    idd_lprun_vddio_ti Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA (uA)

    Pat#

    (uA) (uA)

    1 700.9420 689.2969 16 653.0355 647.2115

    2 653.9544 650.8983 17 705.8274 708.6110

    3 693.7158 677.9120 18 670.7495 669.4368

    4 665.8488 668.2279 19 708.0665 710.0428

    5 703.6901 689.4699 20 674.9866 672.4910

    6 664.3684 666.2164 21 705.7256 706.3126

    7 697.7360 682.9874 22 663.8579 664.8407

    8 660.8971 663.0229 23 697.0236 680.9411

    9 703.8427 699.4233 24 681.2656 676.4615

    10 654.1586 657.7585 25 714.9875 716.1746

    11 704.2498 704.8819 26 677.9474 674.4633

    12 651.6572 644.7659 27 694.4791 680.6906

    13 706.6417 708.6121 28 662.1733 664.2013

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 28 of 46

    14 660.1313 662.5139 29 703.7918 698.5968

    15 699.9243 687.0198 30 671.6684 671.2351

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 645.6254 649.9520 16 615.2083 604.7310

    2 635.2195 631.2140 17 641.1981 636.6210

    3 642.8774 638.7180 18 628.2769 621.3500

    4 613.6769 603.8660 19 634.1245 628.1450

    5 645.0147 643.2790 20 624.9587 617.9510

    6 630.0125 633.6860 21 638.5518 635.7030

    7 642.4703 637.7090 22 628.6342 621.9300

    8 625.3671 620.8770 23 634.4297 628.3030

    9 633.0049 625.1930 24 635.7810 635.3320

    10 632.9733 625.0940 25 645.2692 645.2650

    11 646.9485 652.6510 26 626.6432 620.9280

    12 624.0398 617.3710 27 628.9846 622.0290

    13 643.2845 642.1070 28 618.2712 611.3280

    14 623.5803 615.4960 29 631.0710 624.3610

    15 639.6714 635.8990 30 616.5356 606.7180

    125C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.400 0.479 f- test (P-value) 0.304 0.797

    -40C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.398 0.122 f- test (P-value) 0.197 0.121

    ME00522R00

    idd_ppd_xtal_vddio_ti Parametric Comparison

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 29 of 46

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 157.8680 158.2730 16 163.7657 160.6270

    2 155.8383 157.0590 17 157.4648 158.1310

    3 163.4389 160.3710 18 160.6488 160.1040

    4 158.2231 159.0810 19 160.2044 159.4050

    5 157.9126 158.8720 20 159.4401 159.3240

    6 156.3639 157.8290 21 155.9144 157.5280

    7 159.6965 159.3590 22 158.9739 159.2660

    8 161.8154 160.1090 23 157.8271 158.1710

    9 157.7508 158.1540 24 158.1696 159.0740

    10 162.4518 160.1900 25 164.4013 172.6520

    11 166.5120 161.0790 26 156.4461 153.8570

    12 170.4821 172.6820 27 162.1171 170.1670

    13 168.5520 171.8500 28 156.2030 157.5390

    14 157.3219 158.0180 29 162.7906 160.3340

    15 157.9602 158.9600 30 158.4427 159.1080

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 148.7541 146.9170 16 146.2030 144.8240

    2 146.8248 145.9100 17 145.2377 148.6290

    3 146.6854 147.9080 18 151.1358 147.9890

    4 144.0939 142.7730 19 146.0957 149.6830

    5 145.6184 144.1850 20 145.0696 143.5850

    6 150.2633 147.1880 21 143.8079 142.4160

    7 149.8174 146.9630 22 148.7168 146.6830

    8 146.0090 144.6140 23 146.6933 144.9200

    9 146.6853 144.8730 24 145.3708 143.6620

    10 148.1395 146.4990 25 146.4709 148.8680

    11 145.3960 148.9520 26 147.0744 145.9930

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 30 of 46

    12 147.4683 148.4320 27 146.1723 147.6840

    13 147.2189 146.0390 28 144.5871 143.2690

    14 147.3492 149.0460 29 143.6139 142.3430

    15 145.8685 146.5960 30 145.5187 147.0710

    idd_lprun_vddio_ti Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA (uA)

    Pat#

    (uA) (uA)

    1 685.8553 694.1890 16 672.4021 670.0762

    2 667.4269 660.8439 17 664.6857 658.4439

    3 670.8704 666.9799 18 687.5148 700.6044

    4 644.5447 641.2649 19 677.6553 678.7676

    5 624.9644 634.8084 20 639.7222 635.1882

    6 682.2404 694.0286 21 680.7130 690.0014

    7 654.8628 649.5104 22 658.6933 657.6708

    8 665.8669 659.8719 23 691.9142 701.2693

    9 649.0205 644.4465 24 659.5615 657.9490

    10 652.5972 644.5544 25 679.0394 689.7704

    11 712.5348 714.2591 26 642.5103 640.2068

    12 708.0814 708.6336 27 621.8601 628.8499

    13 696.7050 705.1926 28 670.5300 661.2401

    14 652.7333 645.1936 29 677.0993 677.0023

    15 674.4750 674.3515 30 656.0902 654.3265

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 656.1210 609.9520 16 632.7313 597.7090

    2 640.1536 652.1070 17 605.5851 601.3500

    3 618.8439 585.1930 18 603.6926 580.8770

    4 603.6016 637.9510 19 630.5108 616.6210

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 31 of 46

    5 585.3216 583.8660 20 605.9777 581.9300

    6 659.2778 662.6510 21 604.8222 610.9280

    7 624.7805 595.7030 22 600.7919 575.4960

    8 616.3932 595.0940 23 622.1099 588.3030

    9 615.4522 634.3610 24 622.3157 631.2140

    10 606.2880 582.0290 25 600.7025 611.3280

    11 655.9174 665.2650 26 589.9526 596.7180

    12 637.5488 598.7180 27 642.3231 603.2790

    13 630.3316 655.8990 28 606.9988 633.6860

    14 623.6917 635.3320 29 601.9740 577.3710

    15 618.8513 588.1450 30 587.7134 584.7310

    125C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.714 0.926 f- test (P-value) 0.238 0.494

    -40C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.385 0.139 f- test (P-value) 0.389 0.101

    ME00522Q00

    idd_ppd_xtal_vddio_ti Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 157.3317 156.1860 16 156.1152 155.2680

    2 155.8690 155.1610 17 152.9968 154.0930

    3 161.7552 159.3330 18 156.2727 156.0730

    4 161.0700 157.9180 19 152.9497 154.0560

    5 156.1653 156.0280 20 153.1803 154.2420

    6 155.2867 154.7870 21 158.2335 157.0800

    7 155.2837 154.7100 22 157.8536 156.8190

    8 155.5677 154.7970 23 154.4342 154.5800

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 32 of 46

    9 160.4145 162.7650 24 157.5678 156.4020

    10 162.0886 160.2760 25 154.4844 154.6590

    11 155.5219 154.7910 26 154.3778 154.4080

    12 156.7606 156.0790 27 159.5207 157.6100

    13 151.8261 153.6680 28 159.3086 157.5070

    14 151.9240 153.9540 29 155.9431 155.2500

    15 156.8979 156.1670 30 159.2383 157.3860

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 146.0830 146.2850 16 146.0115 146.1590

    2 145.1447 145.4820 17 148.0538 147.7010

    3 145.3750 146.0270 18 148.9672 147.7870

    4 145.3146 145.9180 19 149.8291 148.2910

    5 144.8343 145.1960 20 150.9869 148.4410

    6 144.8776 143.4470 21 144.7442 144.8220

    7 147.5411 147.4700 22 145.7869 146.0960

    8 147.7032 147.6690 23 146.8028 146.8630

    9 144.3100 144.8090 24 147.7538 147.6810

    10 146.1238 146.5980 25 146.1877 146.6940

    11 147.4079 148.4450 26 149.5723 147.7940

    12 148.1625 147.7190 27 143.3243 144.6480

    13 149.6529 147.9070 28 145.4959 146.0300

    14 148.3952 147.7770 29 147.1296 143.1060

    15 146.0288 146.1950 30 147.2072 147.2500

    idd_lprun_vddio_ti Parametric Comparison

    FHN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA (uA)

    Pat#

    (uA) (uA)

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 33 of 46

    1 675.0104 671.6429 16 649.8862 652.3214

    2 644.4949 646.1519 17 678.0897 678.3209

    3 663.3770 659.3007 18 653.0007 654.5104

    4 645.7506 650.7053 19 652.3265 653.4957

    5 640.8828 639.9178 20 641.8596 641.4273

    6 608.2218 629.0187 21 648.3765 650.7053

    7 665.8458 662.5089 22 671.4996 670.1472

    8 641.5326 641.3948 23 644.5764 650.4173

    9 644.3731 643.2855 24 644.3922 645.6801

    10 650.6520 652.7012 25 634.5316 634.0289

    11 618.7073 631.1086 26 663.8601 662.1395

    12 603.9980 625.6726 27 636.1188 637.0116

    13 673.9006 671.2874 28 662.4575 654.5304

    14 648.5587 651.3354 29 638.8069 637.4057

    15 676.3016 676.4615 30 638.8483 638.3899

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 638.2499 628.3896 16 594.3368 573.0953

    2 615.3829 620.4912 17 609.9083 619.9603

    3 609.7371 615.3981 18 595.7031 584.2083

    4 599.4935 595.6898 19 648.5347 645.0356

    5 605.0765 612.5152 20 629.1217 625.2484

    6 576.5687 565.3423 21 598.3961 592.2435

    7 641.9667 634.4373 22 597.4512 591.3416

    8 622.3800 623.7977 23 598.0068 592.1648

    9 597.1700 588.7818 24 583.4387 572.6790

    10 604.1396 605.7925 25 640.6938 634.3345

    11 601.7706 598.8061 26 639.3875 631.7311

    12 580.4363 572.3362 27 603.9644 605.2344

    13 642.3231 642.9478 28 602.9653 602.9493

    14 621.3585 621.5606 29 599.5836 596.1666

    15 620.8226 621.1282 30 595.2451 581.9008

  • MC56F8002/6 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 34 of 46

    125C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.456 0.678 f- test (P-value) 0.108 0.155

    -40C idd_ppd_xtal_vddio_ti idd_lprun_vddio_ti t- test (P-value) 0.508 0.474 f- test (P-value) 0.173 0.507

    Results: Pass

    5.0 Analysis Conclusions and Verification � Bin-to-bin activity shows 100% correlation of 3430 units at Hot and Cold temperature between the new

    KES-CHINA and the current FSL-TJN-FM.

    � The QA Gate correlation passes at KES-CHINA.

    � Parametric comparison between new KES-CHINA and the current FSL-TJN-FM for 30 good units,

    passes. The results demonstrate that the new KES-CHINA Final Test Site has qualified as a test site for this

    product.

    6.0 Document History:

    Rev Date Originator

    O 24 Oct 2010

    Ji Chang (KES-CHINA, TPE)

    Wei Darcy (TJN MSG PE)

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 35 of 46

    1. Objective:

    This report details the correlation result of the MC9S08RG60 (SOIC28, LQFP32,

    LQFP44) device to demonstrate the KES-CHINA, Tianjin, China, Final Test facility correlates with the current FSL-TJN-FM, Tianjin, China, Final Test facility. The correlation units were first tested at the current FSL-TJN-FM Final Test facility and then both rejects and good units were tested at the KES-CHINA Final Test facility.

    2. General Information

    • Correlation Lot Information:

    Lot # Qty. TJMEA0QEL201 1244 LJME004ZFT00 1200 TJMEA0Q5GQ02 1200

    3. Qualification Plan: 3.1 Requirements: The requirements and acceptance criteria were based on the Freescale specification 12MQS10009G.

    Correlation Plan

    Name Detail Description

    Qual per Correlation Plan, (Y / N ?)

    Acceptance Criteria

    a Bin-to-bin

    Correlation

    Goal: Correlate bin-to-bin per

    production test flow

    Lot quantity: 1 per package

    Units per lot: 1000

    Temperature: 25C, -40C

    Type of units: good, rejects

    Site: FSL-TJN-FM / KES-CHINA

    Y 100% correlation for all good and reject units.

    b QA Gate Qual

    Goal: 100% QC Gate, 0 failures

    Lot quantity: 3

    Units per lot: 1000

    Temperature: Hot Cold

    Type of units: good

    Site: KES-CHINA

    Y 0 failures.

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 36 of 46

    c Parametric

    Comparison

    Goal: Parametric comparison for

    Identify Parametric Tests

    Lot quantity: 1 per package

    Units per lot: 30

    Temperature: 25C,-40C

    Type of units: good

    Site: FSL-TJN-FM/ KES-CHINA

    Y

    t-test and f-test should not demonstrate significant

    difference. P-Unit of Measure

    should be greater than 0.05.

    3.2 General Method: Using the production test program, perform 100% screening of 2 lots at 25C and -40C , 1 lot at 25C temperature, in the current FSL-TJN-FM. Test the same lots under the same conditions in KES-CHINA. Any miss-correlations at KES-CHINA are sent to FSL-TJN-FM for evaluation.

    4.0 Correlation/Qualification Results:

    4.1 Bin-to-bin Correlation Results: Tables below summarize the correlation results. All numbers filled in green boxes means correlation was achieved. All numbers filled in yellow boxes means results did not correlate and requires further explanation.

    Bin-to-Bin Correlation Matrix for Room& Cold Test

    TJMEA0QEL201

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 37 of 46

    FCN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    LJME004ZFT00

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    FCN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 38 of 46

    TJMEA0Q5GQ02

    FRN KES-CHINA RESULT BIN 1 2 3 4 5 6 7 8

    1 PASS

    2 100%

    3 100%

    4 100%

    5 100%

    6 100%

    7 100%

    FS

    L-T

    JN

    -FM

    RE

    SU

    LT

    8 100%

    Results: Pass 4.2 QA Gate results (tested at spec limits):

    Table below shows the QA Gate results Qual in KES-CHINA.

    QA Gate Results

    QA Gate Hot 90 C Cold -40C

    Lot # Pass # Fail # Pass # Fail

    TJMEA0QEL201 100% 0 100% 0

    LJME004ZFT00 100% 0 100% 0

    QA Gate Hot 73 C Cold 0C

    Lot # Pass # Fail # Pass # Fail

    TJMEA0Q5GQ02 100% 0 100% 0

    Results: Pass

    4.3 Parametric Comparison:

    Tables below summarize the parametric data on 30 good units. The following are significant parameters chosen for this comparison:

    • ridd_ram_3V(room)

    • widd_VregON_ram(room)

    • rti_1kHz_8ms_ram(cold)

    • sidd3_ram_3V(cold)

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 39 of 46

    TJMEA0QEL201 ridd_ram_3V(room)Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 3.7808 3.7992 16 3.7099 3.7272

    2 3.7112 3.7292 17 3.7703 3.7982

    3 3.6902 3.7068 18 3.7531 3.7815

    4 3.7104 3.7277 19 3.6264 3.6424

    5 3.7683 3.7834 20 3.8461 3.8619

    6 3.6414 3.6723 21 3.5633 3.6058

    7 3.6475 3.6785 22 3.7840 3.8046

    8 3.7870 3.8131 23 3.6803 3.7014

    9 3.7435 3.7618 24 3.6684 3.7003

    10 3.6953 3.7141 25 3.6968 3.7228

    11 3.7319 3.7536 26 3.7133 3.7307

    12 3.7374 3.7592 27 3.7485 3.7676

    13 3.7189 3.7336 28 3.8031 3.8181

    14 3.7703 3.7944 29 3.7249 3.7445

    15 3.7336 3.7584 30 3.7286 3.7481

    widd_VregON_ram(room) Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 2.2024 2.1999 16 2.1945 2.1880

    2 2.1549 2.1663 17 2.2006 2.1970

    3 2.1888 2.1848 18 2.2240 2.2200

    4 2.1697 2.1822 19 2.1120 2.1276

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 40 of 46

    5 2.2416 2.2341 20 2.2425 2.2492

    6 2.0857 2.1147 21 2.1096 2.1168

    7 2.1605 2.1731 22 2.2465 2.2544

    8 2.2420 2.2444 23 2.1643 2.1746

    9 2.1584 2.1708 24 2.1818 2.1823

    10 2.1896 2.1858 25 2.2237 2.2182

    11 2.1656 2.1774 26 2.2022 2.1982

    12 2.1545 2.1595 27 2.2536 2.2574

    13 2.2059 2.2047 28 2.2413 2.2244

    14 2.1686 2.1797 29 2.2163 2.2150

    15 2.2111 2.2087 30 2.1962 2.1940

    rti_1kHz_8ms_ram(cold) Parametric Comparison

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (ms) (ms)

    Pat#

    (ms) (ms)

    1 8.1032 8.0373 16 7.8780 7.6780

    2 8.5540 8.5333 17 8.2025 8.2000

    3 7.2560 7.1753 18 8.0157 7.9313

    4 9.0063 9.1817 19 8.2930 8.2433

    5 7.6955 7.6060 20 8.5835 8.6480

    6 8.6982 8.9390 21 8.9810 9.1103

    7 7.7993 7.6778 22 8.6535 8.6915

    8 7.6227 7.4750 23 8.2797 8.2103

    9 8.3783 8.2547 24 8.0645 7.9407

    10 8.5555 8.6015 25 7.7595 7.6715

    11 8.9015 9.0038 26 8.4952 8.5183

    12 7.5507 7.4168 27 7.7517 7.6265

    13 7.9623 7.8910 28 8.6605 8.7152

    14 8.6862 8.7710 29 9.2378 9.3815

    15 7.9110 7.8780 30 7.6725 7.6002

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 41 of 46

    sidd3_ram_3V(cold) Parametric Comparison FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (nA) (nA)

    Pat#

    (nA) (nA)

    1 23.0569 24.5757 16 3.6765 3.6954

    2 324.1152 312.9373 17 326.1555 329.8774

    3 349.9480 366.7290 18 337.7076 327.638

    4 -61.0949 -63.5133 19 -71.8051 -77.5931

    5 367.4708 355.1991 20 284.3301 264.6667

    6 283.6454 275.1767 21 221.9329 216.3961

    7 1.1264 1.1343 22 -59.0548 -57.1941

    8 349.6185 357.7490 23 338.9071 316.4185

    9 260.1844 264.8662 24 297.9259 280.5869

    10 5.2065 4.6954 25 3.1664 3.4647

    11 263.4174 261.8063 26 328.1957 338.3475

    12 285.6855 271.0969 27 312.7165 304.9772

    13 34.7871 36.4360 28 354.7192 356.7290

    14 320.0347 344.9772 29 232.6433 224.8662

    15 297.4159 280.5869 30 281.0952 277.2166

    25C ridd_ram_3V widd_VregON_ram t- test (P-value) 0.138 0.758 f- test (P-value) 0.778 0.431

    -40C rti_1kHz_8ms_ram sidd3_ram_3V t- test (P-value) 0.888 0.938 f- test (P-value) 0.364 0.977

    LJME004ZFT00 ridd_ram_3V(room)Parametric Comparison

    FRN

    Pat# FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat# FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 42 of 46

    (mA) (mA) (mA) (mA)

    1 3.7231 3.7318 16 3.6602 3.6333

    2 3.6692 3.6621 17 3.7363 3.7453

    3 3.5404 3.5423 18 3.6877 3.6872

    4 3.6791 3.6858 19 3.7294 3.7389

    5 3.6889 3.6875 20 3.6423 3.6269

    6 3.7444 3.7495 21 3.7188 3.7304

    7 3.6763 3.6711 22 3.7517 3.7495

    8 3.7180 3.7242 23 3.7035 3.7017

    9 3.7172 3.7181 24 3.6253 3.6212

    10 3.7242 3.7377 25 3.6843 3.6865

    11 3.7011 3.6937 26 3.6758 3.6677

    12 3.6930 3.6907 27 3.5971 3.5891

    13 3.5893 3.5482 28 3.6672 3.6574

    14 3.6591 3.6306 29 3.7025 3.7011

    15 3.7159 3.7116 30 3.6167 3.6087

    widd_VregON_ram(room) Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 2.2301 2.2354 16 2.2126 2.2295

    2 2.2037 2.1978 17 2.2507 2.2636

    3 2.1095 2.1221 18 2.2189 2.2311

    4 2.2096 2.2173 19 2.2624 2.2767

    5 2.2147 2.2305 20 2.1971 2.1968

    6 2.2567 2.2759 21 2.2258 2.2341

    7 2.2274 2.2352 22 2.2697 2.2814

    8 2.2354 2.2521 23 2.2259 2.2346

    9 2.2560 2.2680 24 2.1779 2.1778

    10 2.2430 2.2540 25 2.2080 2.2094

    11 2.1945 2.1794 26 2.2029 2.1976

    12 2.2301 2.2376 27 2.1699 2.1761

    13 2.1544 2.1323 28 2.2046 2.2072

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 43 of 46

    14 2.1934 2.1786 29 2.2301 2.2403

    15 2.2640 2.2775 30 2.1636 2.1660

    rti_1kHz_8ms_ram(cold) Parametric Comparison

    FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (ms) (ms)

    Pat#

    (ms) (ms)

    1 7.5125 7.4215 16 7.4535 7.0420

    2 8.5470 8.5892 17 8.2740 8.0390

    3 9.4170 9.3110 18 8.3730 8.3425

    4 8.3270 8.1035 19 8.3518 8.2508

    5 8.4865 8.5022 20 8.3020 8.0520

    6 8.4698 8.5022 21 8.7060 9.2065

    7 8.2168 8.0338 22 7.6803 7.6760

    8 8.3905 8.4383 23 8.6433 8.9522

    9 7.9253 7.8840 24 8.6320 8.9225

    10 10.1307 10.9615 25 8.6702 9.0260

    11 7.8222 7.8085 26 8.1442 7.9732

    12 8.7317 9.2540 27 7.6915 7.7155

    13 8.6805 9.1735 28 8.6085 8.8695

    14 8.7660 9.2880 29 8.1635 8.0170

    15 9.0688 9.3022 30 7.5440 7.4392

    sidd3_ram_3V(cold) Parametric Comparison FCN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (nA) (nA)

    Pat#

    (nA) (nA)

    1 428.9887 438.6875 16 450.8622 451.9424

    2 460.0600 465.7071 17 268.4502 251.0269

    3 338.4561 362.8546 18 331.3699 356.2280

    4 434.8942 442.7659 19 412.0267 422.3737

    5 350.7914 366.4228 20 316.9945 335.3287

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 44 of 46

    6 449.8401 448.3738 21 271.5720 258.8680

    7 306.7746 331.7606 22 412.5377 430.0208

    8 432.8501 442.7659 23 285.3129 295.5691

    9 354.8802 382.0992 24 376.3461 403.5110

    10 343.5537 366.4228 25 482.0327 469.6287

    11 288.3789 313.9197 26 299.6207 326.1534

    12 283.8383 287.9230 27 403.4341 404.0208

    13 467.2139 456.6875 28 464.6589 476.9228

    14 276.6261 275.6893 29 342.5441 365.9131

    15 288.9492 271.0561 30 298.5987 322.5853

    25C ridd_ram_3V widd_VregON_ram t- test (P-value) 0.793 0.568 f- test (P-value) 0.451 0.404

    -40C rti_1kHz_8ms_ram sidd3_ram_3V t- test (P-value) 0.705 0.583 f- test (P-value) 0.135 0.955

    TJMEA0Q5GQ02 ridd_ram_3V(room)Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (mA) (mA)

    Pat#

    (mA) (mA)

    1 3.6692 3.7061 16 3.6645 3.6854 2 3.7425 3.7202 17 3.6939 3.7688 3 3.7285 3.7562 18 3.5613 3.5674 4 3.7004 3.7254 19 3.7058 3.7011 5 3.6569 3.6821 20 3.7216 3.7107 6 3.6455 3.6311 21 3.6655 3.7043 7 3.5762 3.5899 22 3.6964 3.7230 8 3.6859 3.7168 23 3.6974 3.7234 9 3.6448 3.6211 24 3.6645 3.6967

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 45 of 46

    10 3.6820 3.7141 25 3.7134 3.7154 11 3.6230 3.6187 26 3.7148 3.7189 12 3.6558 3.6721 27 3.7098 3.7124 13 3.6811 3.6586 28 3.7293 3.7262 14 3.6454 3.6618 29 3.6372 3.6529 15 3.6280 3.6452 30 3.7502 3.7431

    widd_VregON_ram(room) Parametric Comparison

    FRN

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    FSL-TJN

    Unit of

    Measure

    KESTJ

    Unit of

    Measure

    Pat#

    (uA) (uA)

    Pat#

    (uA) (uA)

    1 2.2275 2.2302 16 2.1975 2.2018

    2 2.2317 2.2386 17 2.2316 2.2378

    3 2.2539 2.2592 18 2.1250 2.1297

    4 2.2329 2.2456 19 2.2465 2.2560

    5 2.2168 2.2246 20 2.2342 2.2537

    6 2.1877 2.196 21 2.1871 2.1944

    7 2.1326 2.1392 22 2.2047 2.2140

    8 2.2036 2.2132 23 2.2143 2.2228

    9 2.1970 2.2016 24 2.1980 2.2026

    10 2.2183 2.2253 25 2.2297 2.2345

    11 2.1838 2.1840 26 2.2511 2.2563

    12 2.2141 2.2168 27 2.2577 2.2610

    13 2.2139 2.2151 28 2.2876 2.2956

    14 2.1760 2.1831 29 2.2022 2.2084

    15 2.1788 2.1840 30 2.2526 2.2591

    25C ridd_ram_3V widd_VregON_ram t- test (P-value) 0.298 0.477 f- test (P-value) 0.699 0.905

    Results: Pass

    5.0 Analysis Conclusions and Verification

  • MC9S08RG60 Correlation Report

    for FSL-TJN-FM to KES-CHINA Final Test Site Expansion

    Page 46 of 46

    � Bin-to-bin activity shows 100% correlation of 3644 units at Room and Cold temperature between the

    new KES-CHINA and the current FSL-TJN-FM.

    � The QA Gate correlation passes at KES-CHINA.

    � Parametric comparison between new KES-CHINA and the current FSL-TJN-FM for 30 good units,

    passes. The results demonstrate that the new KES-CHINA Final Test Site has qualified as a test site for this

    product.

    6.0 Document History:

    Rev Date Originator

    O 24 Oct 2010

    Jennifer Li (KES-CHINA, TPE)

    Liu Xuena (TJN MSG PE)